    Cost Of Non EfficiencyDr. Mohamed H. Helal

    Egypt street lighting and Governmental buildings are consuming nearly 13 % from the total

    generated electric power , only main roads are lighted with over task values while other urbanareas are still in need for public lighting , some main streets in Egypt are turned on at day timeand still no any action from authority to control this flood of wastes , Electric energy issubsidized from natural gas cost to KW/h cost to overcome social barriers .Egyptian Government authorized the ministry of Electricity and energy to deal with the situationin order to minimize the present losses and to turn public lighting to more efficient system.Egyptian Government has allocated a some of 240 Millions Egyptian Pounds to be spend within 2years for energy saving street lighting programs, but with deeply disappointment , the Ministryof Electricity and Energy that lacks of professional expertise didnt follow any of the standardsbasic criterias of lighting efficiency , instead they follow a wrong way that will lead to morelosses in future .While the hole world is getting read of magnetic ballast for HID lamps Egypt will add more

    magnetic ballasts to her roads ??The Egyptian Ministry decided to replace the conventional 250W HPS lamps with 150W HPSand still use magnetic ballasts ??The fact reflects that the Egyptian Ministry is not aware of the problem that Egypt is facing andthat decision makers are too far from correct efficiency track , the case has two scenarios , one islack of efficiency and technology education , the other is personal interest that involvespromotion and marketing of efficiency disqualified products . 47000 Units of 150 Watt HPSlamps with magnetic ballast will replace the present 250W HPS lamps and 60000 Units of 100Watt HPS with magnetic ballast will be installed in side streets .For non professional people the results is clear there will be 100Watt saving and maybe someonewill announce the results are great .This article describes for non professionals the cost that Egypt will pay and the lost opportunities

    150Watt HPS lamps with magnetic ballast

    The high pressure sodium lamps of 150Watt has an initial lumen of 100 ~ 110 ( providing to not increase

    the lamp power than nominated power )lamp lumen depreciation and lamp service life depends online voltage stability , when line voltage is fluctuating from rated voltage HPS lamps will givedifferent results all HPS manufactures will mention clearly that HPS lamps are sensitive to linevoltage fluctuation , lumen maintenance is related to that fact too .Usually lamps life span are made at stabilized line voltage that is totally different than real lifeand will not reflect the reality results , lamp voltage need to be between 90 ~ 100 Volt if exceedsthis limits lamp service life and efficacy will drop dramatically !!!Lumen efficacy has to be tested for the circuit ( Ballast + Lamp ) not for the lamp , when add themagnetic ballast the initial circuit efficacy will drop to 87 lumen /Watt , with an Ra of 22 a

    correction factor of 68% need to be added to reach the usable light level = 59 Lumen/Watt andwhen add the 25% average HPS lumen maintenance the final results is 44 Lumen / Watt and not110 Lumen Watt as some marketing people will sell the product .The scenario is not finished, this calculation is optimistic still , the fact is totally different andviciously deceiving , some other consideration to be taken in order to understand :Street Lights starts at same time during peak load ( 5 Pm in winter and 8 PM summer ) that willcreate a line voltage drop ( 5% less in line voltage = 15~ 20 % less in light level ) while at latenight hours , line voltage will rise up to 235 ~243 Volt ,then we come to the sad reality that street

  • 8/14/2019 Cost of Non Efficiency

    2/10

    lighting in Egypt are consuming 30 ~ 35% at late night hours while they are giving 15% to 20%less light when is needed in areas that power is dropping , ( see what will happened when linevoltage is higher than nominated voltage .

    The Egyptian Electric Ministry will still do same mistake to compare the 250 HPS

    with 150 HPS and not consider the 6 ~ 7 hours night losses .

    Following are some comparison to show the difference between electronic ballast andmagnetic with same HPS lamp under different voltages scenarios ..

    Comparison between Electronic and magnetic HID under different vol

    Electronic HID ballast at 220 Volt Total consumed power = 164.3W , lamp power is 1Lamp PF : > 96% --PF: > 99%--- THDI: < 10% Wave shape is sinusoidal

  • 8/14/2019 Cost of Non Efficiency

    3/10

    Electro Magnetic HID ballast at 220 Volt , Consumed Power is 171 Watt , Lamp Power is 151 WLamp PF = 83% Circuit PF = 88% THDi = 33.3% wave is distorted and light is non stable

  • 8/14/2019 Cost of Non Efficiency

    4/10

    HID ballast at 256 Volt A/C lamp power is stable power is 165W all parameters are Fine circuit consumes evoltage is 94.6

  • 8/14/2019 Cost of Non Efficiency

    5/10

    Magnetic Ballast 150W sodium at 243V Volt Power factor is 88.8% Wave is distorted THDi = > 32% , Circuit Watt lamp power is 192.7 Watt and Lamp Voltageis 122.5 V

    Comment ( THIS LAMP WILL NOT LAST LONG )

  • 8/14/2019 Cost of Non Efficiency

    6/10

    HID Electronic ballast at 160 Volt , Ballast power , power factor , lamp performance is oka

    Electro Magnetic ballast will not start ( needs minimum 196 Volt A/C for starting )

  • 8/14/2019 Cost of Non Efficiency

    7/10

    Electronic Soft start At 4 seconds start only 2.8Watt and 0.017Ampere

  • 8/14/2019 Cost of Non Efficiency

    8/10

    Magnetic start at 4 seconds 1.139Ampere at 222 Volt and 85Watt Power

    Why Egyptian Government is using magnetic Ballast while EU decided

    to stop the use of magnetic ballast and to replace with electronic???

    The answer as I mention can be from lack of efficiency education or from corruption to marketdisqualified products that consumes more energy and has no demands in other countries!In my opinion, both are bad and requires immediate action from our political leaders, wasting ofEgyptian energy need to be stop by all means it concerns our future generations and the future ofEgypt . please refer to :http://www.eup4light.net/assets/pdffiles/Final/VITOEuPStreetLightingFinal.pdf

    The main concern of Egyptian officials is the initial cost invested, tenders in Egypt are based onlower prices with no respect for quality or life cycle cost or savings !!!

    http://www.eup4light.net/assets/pdffiles/Final/VITOEuPStreetLightingFinal.pdfhttp://www.eup4light.net/assets/pdffiles/Final/VITOEuPStreetLightingFinal.pdf
  • 8/14/2019 Cost of Non Efficiency

    9/10

    Its a clear reflection of the silly routine that makes our Nation looses millions of US$ that wecould invest them in building our country and to educate our people ..According to the following study for the only 47000 units or of the 107000 units as first face of theproject when compare electronic to magnetic will be at least 9 Million Egyptian Pounds savingsper year and 72 Millions of Egyptian Pounds during the project life cycle , there are at least 1.8million units to be replaced , within coming years , maybe the picture is clear now !

  • 8/14/2019 Cost of Non Efficiency

    10/10

    For more informations please contact Dr. Mohamed H. Helal [email protected]