2
COSMAN The Leader in RF Medicine Since 1952 cosmanmedical.com The Next Generation in Radiofrequency Pain Management Disposable RF TC Electrodes Facilitate Treatment The hub is easy to hold, radiolucent for clear fluoroscopic views, and color-coded to match cannula length. Improve Safety TCD electrodes are disposable and eliminate the possibility of disease transmission between patients. Reduce Costs Eliminate capital investment, sterilization and replacement costs. TCD electrodes work with straight and curved cannulae. Simplify Your Practice TCD electrodes come sterile packed to eliminate sterilization planning and traceability record keeping. Disposable RF Thermocouple Electrodes TCD

COSMAN Disposable RF TC Electrodes The Leader in RF

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: COSMAN Disposable RF TC Electrodes The Leader in RF

COSMANThe Leader in RF Medicine Since 1952

cosmanmedical.com The Next Generation in Radiofrequency Pain Management

Disposable RFTC Electrodes

Facilitate TreatmentThe hub is easy to hold, radiolucent for clear fluoroscopic views, and color-coded to match cannula length.

Improve SafetyTCD electrodes are disposable and eliminate the possibility of disease transmission between patients.

Reduce CostsEliminate capital investment, sterilization and replacement costs. TCD electrodes work with straight and curved cannulae.

Simplify Your PracticeTCD electrodes come sterile packed to eliminate sterilization planning and traceability record keeping.

Disposable RFThermocoupleElectrodes

TCD

Page 2: COSMAN Disposable RF TC Electrodes The Leader in RF

Color-coded to match thelengths of CC & RFK cannulae

10-cmCannula

TCD-10

5-cmCannula

TCD-5

20-cmCannula

TCD-20

15-cmCannula

TCD-15

cosmanmedical.com© 2010 Cosman Medical, Inc. Rx Only. Read Instructions for Use before using this product.

Cosman Medical, Inc.76 Cambridge StreetBurlington, MA 01803 USA

Tel: +1 (781) 272-6561Fax: +1 (781) 272-6563 [email protected] 0050

COSMANRadiofrequency Pain Management

ISO 13485

®

Disposable RF Electrodes (TCD)Cosman TCD disposable electrodes are indicated for use in radiofrequency lesioning of nerve tissue. Each electrode comes sterile-packed to allow greater flexibil-ity in scheduling cases, or to serve as a backup in the event of accidental electrode contamination. A clinician can keep a small number of TCD electrodes in stock to perform procedures that require unusual electrode lengths, without having to purchase new autoclavable electrodes. Like reusable Cosman CSK electrodes, TCD electrodes contain thermocouple (TC) sensors to monitor RF and Pulsed RF lesion temperatures. Each TCD electrode is compatible with both straight (CC) and curved (RFK) Cosman cannulae, and is color-coded to match cannula length.

SPI 11324 Rev A 20100317

Disposable RF Electrodes (TCD)

~3-meter Cable(CB114-TC)

Electrode with 1-meterleader cable (TCD-10)

Cosman G4RF Generator

Cannula(CC, RFK)

Ground Pad(DGP-PM)TCD Sterile Packing

Part #TCD-5-PTCD-10-PTCD-15-PTCD-20-PCB114-TC

CC-xxx-PRFK-Cxxxx-PDGP-PM-5, 10, 25G4, RFG-1A/B

Description5 cm disposable TC electrodes, 10/pk10 cm disposable TC electrodes, 10/pk15 cm disposable TC electrodes, 10/pk20 cm disposable TC electrodes, 10/pkSterilizable cable, ~3 m, TCD to G4 or RFG-1A/B

Straight disposable RF Cannulae, 10/pkCurved disposable RF Cannulae, 10/pkDisposable ground pad, 5, 10, or 25/pkFour-output or one-output RF generators

Note: xxx and xxxx refer to a variety of length and tip dimensions.