7
Corporate Presentation Innu-Science Canada TITRE DE LA DIAPO Titre du chapitre 1 November 2010 Innu-Science Comparing our biotechnology to leading chemistry detergents

Corporate PresentationInnu-Science Canada TITRE DE LA DIAPO Titre du chapitre 1 November 2010 Innu-Science Comparing our biotechnology to leading chemistry

Embed Size (px)

Citation preview

Page 1: Corporate PresentationInnu-Science Canada TITRE DE LA DIAPO Titre du chapitre 1 November 2010 Innu-Science Comparing our biotechnology to leading chemistry

Corporate Presentation Innu-Science Canada

TITRE DE LA DIAPO

Titre du chapitre 1

November 2010

Innu-ScienceComparing our biotechnology to

leading chemistry detergents

Page 2: Corporate PresentationInnu-Science Canada TITRE DE LA DIAPO Titre du chapitre 1 November 2010 Innu-Science Comparing our biotechnology to leading chemistry

2

Corporate Presentation March 2012Innu-Science Deutschland

Introduction

For transparency & ethical reasons, Innu-Science Scandinavia conducted a test to compare it’s biotechnology Nu-Niit to a leading chemical detergent.

The following data was provided by Swerea IVF in June 2012.

Swerea IVF ABP.O. Box 104 SE-431 22 Mölndal, SwedenTel: +46 31 706 60 [email protected]

Page 3: Corporate PresentationInnu-Science Canada TITRE DE LA DIAPO Titre du chapitre 1 November 2010 Innu-Science Comparing our biotechnology to leading chemistry

3

Corporate Presentation March 2012Innu-Science Deutschland

Data

Product and washing temperature:

Nu-Niit30°C

Leading chemical detergent85°C

Number of washes per detergent:

3

Number of soiled cloths per wash cycle:

10

Ballast:

Gray knitted fabric

Drying of webs:

"dry flat" at room temperature

Dirt per Material:

3 grams of canola oil

The cloths were weighed before and after washing.

Dosage of detergent according to the manufacturer's recommendations.

Page 4: Corporate PresentationInnu-Science Canada TITRE DE LA DIAPO Titre du chapitre 1 November 2010 Innu-Science Comparing our biotechnology to leading chemistry

4

Corporate Presentation March 2012Innu-Science Deutschland

Percentage of residual fat after washing

Leading Chemical De-tergent

Nu-Niit0.0%2.0%4.0%6.0%8.0%

10.0%12.0%14.0%16.0%

Results

7.2%@ 30°C

14.8%@ 85°C

Page 5: Corporate PresentationInnu-Science Canada TITRE DE LA DIAPO Titre du chapitre 1 November 2010 Innu-Science Comparing our biotechnology to leading chemistry

5

Corporate Presentation March 2012Innu-Science Deutschland

In conclusion

7.2%@ 30°C

14.8%@ 85°C

Nu-Niit is twice as effective at reducing oily dirt even using water at lower temperature (30°C vs. 85°C)

It also delivered the following results:65% less Carbon Dioxide due to the washing process70% Less Energy95% Less Chemical Consumption Fewer Mop Changes Less Washing required in useMaterials last at least twice as long

Page 6: Corporate PresentationInnu-Science Canada TITRE DE LA DIAPO Titre du chapitre 1 November 2010 Innu-Science Comparing our biotechnology to leading chemistry

6

Corporate Presentation March 2012Innu-Science Deutschland

Absorption test according to ISO 9073-12

7.2%@ 30°C

14.8%@ 85°C

0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.00.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

seconds

Ab

sorp

tio

n c

ap

acit

y in

gra

ms

Reference (New Cloth) Nu-Niit - 30°C Leading chemical dertergent - 85°C

Page 7: Corporate PresentationInnu-Science Canada TITRE DE LA DIAPO Titre du chapitre 1 November 2010 Innu-Science Comparing our biotechnology to leading chemistry

7

Corporate Presentation March 2012Innu-Science Deutschland

In conclusion

7.2%@ 30°C

14.8%@ 85°C

What is essential is that the microfiber cloth retains its absorptive capacity after washing. Absorption capacity should be both fast and high for optimum cleaning efficiency. Using microfibers capillary forces along with Bacteria is more efficient and contributes to a hygienic cleaning. Using the chemical cleaning agent shows us a clear reduction of the absorption capacity and possibly a deterioration in cleaning performance.

Although any residual chemicals may affect the absorption… No reduction in absorbance can be detected washing with Nu-Niit at 30°C.