Corning's Fiber Passive Solutions

Manny GarciaSolutions Engineer

3Corning Internal.

© 2015 Corning Incorporated ..

Cable OptionsLoose Tube Cable

Composite Cable

Ribbon Cable

Tight Buffered Cable

Indoor Ribbon Cable

4Corning Internal.

© 2015 Corning Incorporated ..

Cable Options• Types of Cables

– Loose Tube– Ribbon Cable / Indoor– Composite Cable– Tight Buffered Cable

5Corning Internal.

© 2015 Corning Incorporated ..

Cable Options• Outdoor Cable

– Has a UV protected jacket for exposure to sun– Has some type of water blocking material to prevent water absorption– Can be placed in duct or direct buried

• Indoor Cable– Has a flame rating to be used indoors– Typically has a thicker coating for direct termination– Should not be used outside; even in duct

• Indoor/Outdoor Cable– Has a UV protected jacket– Has water blocking material– Has a flame rating in order to be used indoors

6Corning Internal.

© 2015 Corning Incorporated ..

Cable Options• Riser vs. Plenum

– Indoor cable can be rated as general, riser or plenum– Riser cable is cable that is typically run between floors in non-

plenum areas– Plenum cable is cable that is laid in the plenum spaces of

buildings – typically drop ceilings and most horizontal runs– Plenum cable can be used in riser areas– Riser cable cannot be used in plenum areas– Cables without a flame rating can only be run 50ft inside a

building before having to be placed in conduit or transition to a flame-rated cable

7Corning Internal.

© 2015 Corning Incorporated ..

Cable OptionsMIC®

CableALTOS®

CableFREEDM®

Cable

Fiber Count (max) 216 432 432 864 288 72

Available Flame Rating

Riser/Plenum

Riser/Plenum

General GeneralRiser/Plenum

Riser/Plenum

Supported Environment Indoor Indoor Outdoor Outdoor

Indoor/Outdoor

Indoor/Outdoor

Buffer Tube Fan-out Kits Required for

TerminationNo Yes Yes Yes Yes No

Armor Available Yes Yes Yes Yes Yes Yes

Gel Free Yes Yes Yes/No Yes/No Yes Yes

FREEDM®

One CableALTOSRibbon Cable

Ribbon Cable

8Corning Internal.

© 2015 Corning Incorporated ..

Cable Stocking PlanPart Number Description

Fiber Only Cables012E88-33131-29 12f, MIC Plenum, SM

024E88-33131-29 24f, MIC Plenum, SM

024EC7-14101-30 24f, Ribbon Riser, SM

024EC8-14101-20 24f, Ribbon Plenum, SM

048ECF-14101-31 48f, FREEDM Ribbon Riser, SM

048EC8-14101-20 48f, Ribbon Plenum, SM

072EC7-14101-30 72f, Ribbon Riser, SM

096EC8-14101-20 96f, Ribbon Plenum, SM

144EC8-14101-20 144f, Ribbon Plenum, SM

Hybrid (Composite) Cables006UT8-41H01M20 4x16AWGx6f

012UT8-61H01M20 6x16AWGx12f

012UT8-M1H01M20 12x16AWGx12f

012UD8-41G01M20 4x14AWGx12f

012UD8-M1G01M20 12x14AWGx12f

9Corning Internal.

© 2015 Corning Incorporated ..

Ordering Cable - What do you need to know• Ask about specific reel lengths before the order is placed• Corning does not not offer an 18AWG• Plenum indoor composite used in ONE Wireless Platform

solutions• All cables come with a one year warranty against

manufacturing defects• We have a network of Pioneers that are available for

installation help and troubleshooting

10Corning Internal.

© 2015 Corning Incorporated ..

Possible Ribbon Composite Configurations

11Corning Internal.

© 2015 Corning Incorporated ..

Splice Comparison• Single Fiber

– ~ 2 minutes per splice– ~ 25 minutes for a 12 fiber cable– ~ $25 per splice– ~ $300 for a 12 fiber cable

• Ribbon– ~ 8 minutes per splice– ~ 13 minutes if you have to ribbonize– ~ $125 per splice

12Corning Internal.

© 2015 Corning Incorporated ..

National Electric Code – Key Requirements & Example

• Max Power per circuit at Power Source: 100VA

• Max Voltage at Power Source: 60V (-48V typical)

EXAMPLE

High Power Line leaves 48V DC Supply – Example 50Amp

Fuse Panel brings power below 100W: Example 48V x 1.5Amp fuse = 72W

3 16AWG Cu Pair leave Fuse Panel @ max 72W / each. Will use a pair for each modules within QSX cabinet

Cu Pairs travel 500ft Power Draw of 58.1W for 700 and AWS add-on’s and 39.2W for Cell/PCS RHU

** New ATT requirement requires that we design to -41.89VDC to maximize battery life (41.89 x 2Amp = 83.78 max output)

13Corning Internal.

© 2015 Corning Incorporated ..

Composite Cable Deployment Examples

14Corning Internal.

© 2015 Corning Incorporated ..

DAS Composite Cable Offerings

15Corning Internal.

© 2015 Corning Incorporated ..

Max Cable Distances14AWG16AWG

850ft 1350ft

500ft 800ft

12AWG

2100ft

1280ftHX 9 Pair

MA2000

16Corning Internal.

© 2015 Corning Incorporated ..

How do I determine composite cable length?• Line Power Calculator• Need to understand the following for each remote type:

– Minimum Voltage– Minimum Input Power– Maximum Voltage– Maximum Output Power

17Corning Internal.

© 2015 Corning Incorporated ..

How do I determine composite cable length?

MA1000 (Dual Band)• Min. Voltage – 20V• Min. input power – 29W • 1 conductor pair required

MA1000 (Tri/Quad Band)• Min. Voltage – 25V• Min. input power – 50W • 2/3 conductor pairs required

18Corning Internal.

© 2015 Corning Incorporated ..

How do I determine composite cable length?

MA2000 (TSX/QSX)• Min. Voltage – 25V• Min. input power – 50W • 2/3 conductor pairs required

19Corning Internal.

© 2015 Corning Incorporated ..

How do I determine composite cable length?

HX SISO

• Min. Voltage – 36V• Min. input power – 350W / # of pairs

• Ex. 58.33W using 6 pair• Up to 9 conductor pairs required

HX Outdoor

• Min. Voltage – 36V• Min. input power – 340W• 85W each for 4 conductor pairs required

20Corning Internal.

© 2015 Corning Incorporated ..

How do I determine composite cable length?

GX

• DC version is available• Cannot be used with

composite cable

21Corning Internal.

© 2015 Corning Incorporated ..

How do I know what size power plant to use?– By knowing the distance to each remote and the remote type

we can calculate the power required in the closet.– It is a very manual process but can be used to generate load

requirements– If Corning does the Fiber design, ask Corning Engineering to

size Power Plant

22Corning Internal.

© 2015 Corning Incorporated ..

How to Pick the Right Corning Fiber Hardware?• Questions to ask about Hardware

– Indoor or Outdoor?– Wall mount or Rack Mount?– Direct Termination or Pigtail Splicing?– What connector/fiber type will be used?– Head End, Consolidation Point, or Remote?

23Corning Internal.

© 2015 Corning Incorporated ..

Picking the Right Corning Fiber Hardware• Head End Hardware

– Typically large fiber count housings– Typically rack mount– Need to accommodate multiple cable entries

24Corning Internal.

© 2015 Corning Incorporated ..

Picking the Right Hardware• Remote Location

– Rack mount or wall mount?– Limited space?– Environmentally sealed?– How many fibers at each location?

25Corning Internal.

© 2015 Corning Incorporated ..

Picking the Right Hardware• Head End Hardware

PR4 Housing- 144 or 288 fibers- SC/APC or LC/APC- Splicing in the rear- 19in or 23in rack mount- 4Us

CCH-04U Housing- 144 or 288 fibers- SC/APC or LC/APC- Splicing in cassettes- Holds the same cassettes as 1U

version- 19in or 23in rack mount- 4Us

26Corning Internal.

© 2015 Corning Incorporated ..

Corning Local Area Network Hardware SolutionsSingle Panel Housings

Corning Cable Systems Single-PanelHousing (SPH-01P) is a cost-effectivehousing for storage, protection andtermination of optical fiber cables. TheSPH-01P accepts standard LANscape®Solutions CCH connector panels andoffers protection for the fiber cable andconnectors for indoor wall-mountinstallations.

SPH-01P Design ConsiderationsMounting Wall-mountableEnvironment IndoorTermination Direct Termination Splicing inside the hardwareFiber Capacity and Type 12 connector splice capacity 12 2.5-mm connector capacity 24 1.25-mm connector capacity

27Corning Internal.

© 2015 Corning Incorporated ..

Corning Local Area Network Hardware SolutionsRack-Mount Solutions

Corning Cable Systems Pretium®Connector Housings are designed forthe LAN and data center environment.Mountable in 19- or 23-in (optional)equipment racks or cabinets, thehousings are four inches deeper thanstandard connector housings andprovide easy, open access to connectorsfor cleaning, moves and additions orother changes.

PCH Design ConsiderationsMounting Rack mountableEnvironment IndoorTermination Preterminated Solutions Direct Termination Splicing inside the hardwareFiber Capacity and Type (12) 2.5mm ferrule connectors

(SC, ST® compatible, FC) (24) 1.25-mm ferrule connectors

(LC)

28Corning Internal.

© 2015 Corning Incorporated ..

Closet Connector Housing InnovationsCCH Overview

CCH-04U 4 rack-units 288 LC or 144 SC/ST compatible connectors

CCH-02U 2 rack-units 96 LC or 48 SC/STcompatible connectors

CCH-03U 3 rack-units 144 LC or 72 SC/ST

compatible connectors

CCH-01U 1 rack-unit 48 LC or 24 SC/STcompatible connectors

Single person rack mountable Fusion Splice or Direct termination

No additional splice hardware requiredFull installation videos available on Corning Cable System’s website and You Tube

Closet Connector Housing Family

Cassette Splice up to 24 LCs Direct terminate

29Corning Internal.

© 2015 Corning Incorporated ..

Closet Connector Housing OverviewCCH-01U

CCH-01U

Accessing

Slack Management

Routing

Strain-ReliefJumper Management

Strain-Relief

Routing

30Corning Internal.

© 2015 Corning Incorporated ..

Closet Connector Housing OverviewSplice Cassette

CassetteEasy Routing

Slack Storage

Heat Shrink Holder

Routing

Cassette’s in a CCH-04UCassette’s in a CCH-01U

31Corning Internal.

© 2015 Corning Incorporated ..

Corning Rack Mounted Hardware SolutionsCCH and PCH Compared

Closet Connector Housing (CCH) Pretium Connector Housing (PCH)

1U 2U 3U 4U 1U 2U 3U 4U

Configurations YES YES YES YES YES YES NO YES

Fiber Capacity (SC/ST) 24 48 72 144 24 48 N/A 144

Fiber Capacity (LC Duplex) 48 96 144 288 48 96 N/A 288

Splice Capacity (Single Fiber) 48 96 144 288 24 96 N/A 144

Height (in.) 1.75 3.5 5.25 7 1.75 3.5 N/A 7

Width (in.) 17 17 17 17 17 17 N/A 17

Depth (in.) 17 17 17 17 16 16.5 N/A 16

Weight (lbs.) 11 14.2 17 17.6 11 12.6 N/A 16.5

32Corning Internal.

© 2015 Corning Incorporated ..

Corning Rack Mounted Hardware SolutionsWhen do I chose one over the other?

Purchase CCH for the following:• Standard every-day rack-mounted connector

installation and splicing (inside the housing) where ease of use, intuitiveness, and maximizing capacity is key

• Installations where cost effectiveness and availability are paramount

Purchase PCH for the following:• The look, fit, and feel of a primarily

metallic housing is preferred• Optimized integration with CCS Plug &

Play Modules and Trunks

33Corning Internal.

© 2015 Corning Incorporated ..

Offering: The Hutton Menu

• Warehousing and distribution• Order fulfillment and management• Procurement management• Asset tagging• Staging and kitting• Cable processing• Jumper assembly• Microwave configuration & test• Support pallet bundling• Final mile delivery• Cabinet integration• RMA and advanced replacement• Spares management• Engineering Support

Hutton’s Unmatched Menu of Wireless Services

34Corning Internal.

© 2015 Corning Incorporated ..

In-Building DAS Value Proposition

• Business Segment Solely Focused and Dedicated to In-Building DAS

• Engineering Resources for Design and Technical Support

• Complete offering of In-Building DAS Products for One-Stop Sourcing

• Stocking Programs with Key Supplier Partners• Bundling and Staging Capabilities for Complete, Just

In Time, On Site Project Deliveries

35Corning Internal.

© 2015 Corning Incorporated ..

In-Building DAS Product Offering

• Fiber DAS Active Equipment• Repeaters/BDA’s • Coaxial cables, connectors, jumpers and accessories• Antennas, antenna mounts, lightning protection,

grounding, etc.• Passive components, such as couplers and splitters• Equipment racks, back-up power, test equipment,

installation aids and tools• Fiber cabling, jumpers/pigtails and accessories

36Corning Internal.

© 2015 Corning Incorporated ..