Cooling-channel configurations. Baffle, bubbler, and thermal pin. Thermal pin heat transfer efficiency. Residual flow stresses due to frozen-in molecular orientation. Residual thermal stress in a "free-quenching" part. Thermal-induced residual stress caused by unbalanced cooling. - PowerPoint PPT Presentation

Citation preview

Page 1: Cooling-channel configurations

Cooling-channel configurations Cooling-channel configurations

Page 2: Cooling-channel configurations

Baffle, bubbler, and thermal Baffle, bubbler, and thermal pinpin

Page 3: Cooling-channel configurations

Thermal pin heat transfer Thermal pin heat transfer efficiencyefficiency

Page 4: Cooling-channel configurations

Residual flow stresses due to Residual flow stresses due to frozen-in molecular orientationfrozen-in molecular orientation

Page 5: Cooling-channel configurations

Residual thermal stress in a Residual thermal stress in a "free-quenching" part"free-quenching" part

Page 6: Cooling-channel configurations

Thermal-induced residual Thermal-induced residual stress caused by unbalanced stress caused by unbalanced cooling cooling

Page 7: Cooling-channel configurations

The pvT curves The pvT curves

Page 8: Cooling-channel configurations

Processing and design Processing and design parameters that affect part parameters that affect part shrinkage shrinkage

Page 9: Cooling-channel configurations

Differential shrinkage for both Differential shrinkage for both unfilled and filled materials unfilled and filled materials

Page 10: Cooling-channel configurations

Part warpage due to non-Part warpage due to non-uniform cooling uniform cooling

Page 11: Cooling-channel configurations

Larger volumetric shrinkage Larger volumetric shrinkage due to the high crystallization due to the high crystallization level level

Page 12: Cooling-channel configurations

The poor cooling of the mold The poor cooling of the mold wall on the ribbed sidewall on the ribbed side

Page 13: Cooling-channel configurations

Part design with thickness Part design with thickness variationvariation

Page 14: Cooling-channel configurations

A thin uniform wall with ribs is A thin uniform wall with ribs is preferred to a thick wall preferred to a thick wall

Page 15: Cooling-channel configurations

Jetting(I)Jetting(I)

Page 16: Cooling-channel configurations

Jetting(II)Jetting(II)

 

                 

                        

Page 17: Cooling-channel configurations

Air TrapsAir Traps

Page 18: Cooling-channel configurations

HesitationHesitation

Page 19: Cooling-channel configurations

Weld lines and meld lines (I)Weld lines and meld lines (I)

Page 20: Cooling-channel configurations

Weld lines and meld lines Weld lines and meld lines (II)(II)

Page 21: Cooling-channel configurations

Weld lines and meld lines (III)Weld lines and meld lines (III)

Page 22: Cooling-channel configurations

Sink marks and voidsSink marks and voids

Page 23: Cooling-channel configurations

FlashFlash

Page 24: Cooling-channel configurations

Black specks/black streaksBlack specks/black streaks

 

                               

                                    

Page 25: Cooling-channel configurations

BrittlenessBrittleness

Page 26: Cooling-channel configurations

Burn marksBurn marks

Page 27: Cooling-channel configurations

DelaminationDelamination

Page 28: Cooling-channel configurations

Fish eyes Fish eyes

Page 29: Cooling-channel configurations

FlashFlash

Page 30: Cooling-channel configurations

Flow marks Flow marks

Page 31: Cooling-channel configurations

RipplesRipples

Page 32: Cooling-channel configurations

Cause of ripples Cause of ripples

Page 33: Cooling-channel configurations

Silver streaks Silver streaks

Page 34: Cooling-channel configurations

CAE provides an integrated CAE provides an integrated environmentenvironment

Page 35: Cooling-channel configurations

设计方案 设计方案 11

  长流道要求高压力 观察报告:流动长度与零件长度一样。 问题:加长流动长度一般需要加大注射压力来填充零件。

 熔体前沿以不同的速度流动

观察报告:在恒定的填充速度下,熔体前沿的速度( MFV)随时间变化,这与熔体前沿的面积(MFA)有关。 问题:不同的 MFV将引起零件表面分子或者纤维方向不一致,可能引起收缩和翘曲。

扇形浇口开在一侧,保持恒定的填充速度曲线 

Page 36: Cooling-channel configurations

设计方案 设计方案 22

设计修改:中心浇口  中心浇口使流动长度变短

观察报告:设计的浇口在零件的几何中心。 方案改进:与设计 1相比流动长度的最大值减小了,这样所需的注射压力也减小了。

 变化的熔体前沿速度仍存在      问题:       初期的放射形的填充形式会残留下来,这是不希望      看 到的。

Page 37: Cooling-channel configurations

设计方案 设计方案 33

设计修改:取理想的填充速度曲线 

取可变的填充速度曲线,获得恒定的熔化前沿速度

方案改进:使用 CAE分析软件所建议的最佳填充速度曲线可以消除MFV的变化。 

Page 38: Cooling-channel configurations

设计方案 设计方案 44

可变的填充速度曲线   恒定的熔体前沿速度 观察报告:

熔体前沿的推进在轮廓间的距离恒定,这表明MFV恒定。

 最佳填充时间 方案改进:通过注射时间扫描找到最加填充时间范围,以使注射压力最小。

Page 39: Cooling-channel configurations

设计方案 设计方案 4 (4 ( 续续 ))

  太高的注射压力 观察报告:如果所需压力超过机器的最大压力,那么必须改变工艺条件或者设计方案。

 比较供选的工艺方案 反复迭代设计:分析比较可选方案的熔体和模壁的温度﹑浇口和流道的设计或零件的厚度,反复比较所有的方案,选择最佳方案。

Page 40: Cooling-channel configurations

设计方案 设计方案 55

设计修改:改变浇口设计 改变浇口设计 方案改进: 

如果注射压力一直很高,那么可以考虑使用多浇口来减小流动长度。这样将会减少所需的注射压力。

再次使用 CAE软件可以很快确定正确的浇口位置和最佳填充速度曲线。

Page 41: Cooling-channel configurations

设计方案 设计方案 66

设计修改:三浇口,热浇注系统

更低的注射压力和更短的流动长度 方案改进:用多个浇口可使流动长度显著减小,以便减小所需注射压力。

如果要减小流体废料和进一步减小在流道中的压力损失,可以考虑使用热流道系统。

 多个浇口将会导致熔接缝 问题:    多浇口系统的主要缺陷是熔接缝。 CAE分析软件可以预测熔接缝位置。 如果熔接缝的位置是不可接受的,那么就必须修改设计(如改变浇口的位置或尺寸)。

Page 42: Cooling-channel configurations

设计方案 设计方案 77

设计修改:电子阀浇口,实现浇口连续的打开和关闭的控制

  最初只有中心浇口的电子阀打开 方案改进:将电子阀顺序打开可以在保持多浇口的同时消除熔接缝。

当熔体到达时候,下面的浇口再打开

在熔体到来之前,下面的浇口一直关闭。当熔体到达时浇口才打开。

Page 43: Cooling-channel configurations

设计方案 设计方案 7 (7 ( 续续 ))

  熔体温度分布 方案改进: 由 CAE显示的熔体温度分布说明了在填充的过程中零件不同位置温度随时间的变化。

 模壁的剪切力分布 进一步改进:当最大剪切力超过一定的水平时,熔体的破裂和空间的不稳定性就会发生。 CAE所显示的模壁剪切压力分布可精确的指出潜在的问题。

Page 44: Cooling-channel configurations