Conventional Jackets Figure 1: Conventional Jacket "Conventional jackets" can be divided into two (2) main categories: baffled and non-baffled. Baffled jackets often utilize what is known as a spirally wound baffle. The baffle consist of a metal strip wound around the inner vessel wall from the jacket utility inlet to the utility outlet. The baffle directs the flow in a spiral path with a fluid velocity of 1-4 ft/s. The fabrication methods does allow for small internal leakage or bypass around the baffle. Generally, bypass flows can exceed 1/3 to 1/2 of the total circulating flow. Conventional baffled jackets are usually applied with small vessels using high temperatures where the internal pressure in more than twice the jacket pressure. Spirally baffled jackets are limited to a pressure of 100 psig because vessel wall thickness becomes large and the heat transfer is greatly reduced. In the case of an alloy reactor, a very costly vessel can result. For high temperature applications, the thermal expansion differential must be considered when choosing materials for the vessel and jacket. Design and construction details are given in Division 1 of the ASME Code, Section VIII, Appendix IX, "Jacketed Vessel". Heat Transfer Coefficients: Conventional Jackets without Baffles (h j D e / k) = 1.02 (N Re ) 0.45 (N Pr ) 0.33 (D e / L) 0.4 (D jo / D ji ) 0.8 (N Gr ) 0.05 Eq. (1)

Conventional Jackets

Embed Size (px)

Citation preview

Page 1: Conventional Jackets

Conventional Jackets

Figure 1: ConventionalJacket

"Conventional jackets" can be divided into two (2) main categories: baffled and non-baffled. Baffled jackets often utilize what is known as a spirally wound baffle. The baffle consist of a metal strip wound around the inner vessel wall from the jacket utility inlet to the utility outlet. The baffle directs the flow in a spiral path with a fluid velocity of 1-4 ft/s. The fabrication methods does allow for small internal leakage or bypass around the baffle. Generally, bypass flows can exceed 1/3 to 1/2 of the total circulating flow.

Conventional baffled jackets are usually applied with small vessels using high temperatures where the internal pressure in more than twice the jacket pressure.

Spirally baffled jackets are limited to a pressure of 100 psig because vessel wall thickness becomes large and the heat transfer is greatly reduced. In the case of an alloy reactor, a very costly vessel can result. For high temperature applications, the thermal expansion differential must be considered when choosing materials for the vessel and jacket. Design and construction details are given in Division 1 of the ASME Code, Section VIII, Appendix IX, "Jacketed Vessel".

Heat Transfer Coefficients: Conventional Jackets without Baffles

(hj De / k) = 1.02 (NRe) 0.45 (NPr) 0.33 (De/ L) 0.4 (Djo/ Dji) 0.8 (NGr) 0.05 Eq. (1)

Figure 2: Schematic of ConventionalJacket

Where:hj = Local heat transfer coefficient on the jacket side

Page 2: Conventional Jackets

De = Equivalent hydraulic diameterNRe = Reynolds NumberNPr = Prandtl NumberL = Length of jacket passageDjo = Outer diameter of jacketDji = Inner diameter of jacketNGr = Graetz number

The Reynolds Number is defined as:

NRe = DVρ/μWhere D is the equivalent diameter, V is the fluid velocity, ρ is the fluid density, μ and is the fluid viscosity.

The Prandtl Number is defined as:

NPr = Cp μ / kWhere Cp is the specific heat, μ is the viscosity, and k is the thermal conducitivity of the fluid.

The Graetz Number is defined as:

NGr = (m Cp) / (k L)Where m is the mass flow rate, Cp is the specific heat, k is the thermal conducitivity, and L is the jacket passage length.

The equivalent diameter is defined as follows:

De = Djo-Dji for laminar flowDe = ((Djo)2 - (Dji)2)/Dji for turbulent flow

Page 3: Conventional Jackets

Conventional Jackets with Baffles

For conventional jackets with baffles, the following can be used to calculate the heat transfer coefficient:

hj De/k= 0.027(NRe)0.8 (NPr)0.33 (µ/µw)0.14 (1+3.5 (De/Dc) ) ( For NRe > 10,000) Eq. (2)hj De/k = 1.86 [ (NRe) (NPr) (Dc/De) ] 0.33 (µ/µw)0.14 ( For NRe < 2100 ) Eq. (3)

Figure 3: Schematic of Conventional Jacketwith Baffle

Two new variables are introduced. Dc is defined as the centerline diameter of the jacket passage. It is calculated as Dji + ((Djo-Dji)/2). The viscosity at the jacket wall is now defined as µw. When calculating the heat transfer cofficients, an effective mass flow rate should be taken as 0.60 x feed mass flow rate to account for the substantial bypassing that will be expected. De is defined at 4 x jacket spacing. The flow cross sectional area is defined as the baffle pitch x jacket spacing.