3
, Series 5500-8000 High quality acrylic enclosures built to customer specifications up to 125 ft 3  (3540l). Configure for any contained environment such as uncontrolled SEALED WORKING CHAMBER, CONTAMINATION CONTROL ENCLOSURE, MIXING CHAMBER or CONTROLLED HUMIDITY and/or TEMPERATURE ENVIRONMENT.  Use for storage, conditioning, assembly, testing etc. of raw material or product in electronic, electrostatic, biomedical, pharmaceutical, military, university research, R&D plus other applications. Features: Built to customer specifications Up to 125 ft 3 (3540 l) work space   ¼”or 3/8” (6 or 9mm) clear & white acrylic   PS30 welded seams Single or multi-door access 8” (203mm) glove or bare hand iris access Optional Static Dissipative Acrylic Available RH & temperature control Optional cart with ESD casters CUSTOM ENCLOSURES

Controlled Humidity

Embed Size (px)

Citation preview

Page 1: Controlled Humidity

8/3/2019 Controlled Humidity

http://slidepdf.com/reader/full/controlled-humidity 1/3

, Series 5500-8000High quality acrylic enclosures built to customer specifications up to 125 ft 3 (3540l). Configure for any contained environment such as uncontrolledSEALED WORKING CHAMBER, CONTAMINATION CONTROL ENCLOSURE,

MIXING CHAMBER or CONTROLLED HUMIDITY and/or TEMPERATUREENVIRONMENT. Use for storage, conditioning, assembly, testing etc. of rawmaterial or product in electronic, electrostatic, biomedical, pharmaceutical,military, university research, R&D plus other applications.

Features:Built to customer specifications

Up to 125 ft 3 (3540 l) work space

¼”or 3/8 ” (6 or 9mm) clear & white acrylic

PS30 welded seams

Single or multi-door access

8” (203mm) glove or bare hand iris access

Optional Static Dissipative Acrylic

Available RH & temperature control

Optional cart with ESD casters

CUSTOM ENCLOSURES

Page 2: Controlled Humidity

8/3/2019 Controlled Humidity

http://slidepdf.com/reader/full/controlled-humidity 2/3

General Description:Custom chambers and systems etc can vary anywhere from modifications to standard ETSacrylic enclosures such as size, adding doors and extenders, HEPA filters, addition or removalof glove and access ports, addition of nonstandard operating systems etc to a totally newdesign.

Shown below are several examples of custom systems utilizing lift-off and removable side paneldesigns, extensions, HEPA filtering, and adding nonstandard operating systems

Chamber on wheeled base Cooling added to chamber Custom size with double door

Temp & dry gas added Extender column added Filter and fan added

Performance Characteristics:The ability of an enclosure to maintain and hold a given humidity level is a function of cabinetdesign (size, shelves and doors), frequency of access, and operating systems and controllersused. The following charts show the time typically required to decrease and increase humidity ina 13 ft 3 (370 l) enclosure (Blue = RH, Red = T ° C) using an ETS humidity control system withCALCOMMS software.

Rate of humidity decrease Rate of humidity increase

Page 3: Controlled Humidity

8/3/2019 Controlled Humidity

http://slidepdf.com/reader/full/controlled-humidity 3/3

Available Humidity/Temperature Control Configurations:Series 5500 Custom Enclosures can be ordered as a freestanding enclosure, equipped withcustomer selected controllers and operating systems including

Dual purge N 2 gas valve with or without controlSingle point (5% RH, N 2, etc.) controlled low humidity systemAdjustable dehumidification system (desiccant/pump or gas valve)Adjustable ultrasonic humidification systemMicroprocessor based humidity control systems, (optional software pkg.)

Standard Humidity/Temp. Operating Systems & Accessories:Custom enclosures can be configured using the following operating systems and accessories:

Dehumidification: Accessories:1.0 lb Desiccant/Pump @ 0.6 cfm Antechamber2.5 lb Desiccant/Pump @1.2 cfm 5 lb jar of desiccantSelf-regenerating molecular sieve HEPA Filters

Dry Gas Hypalon GlovesHumidification: Iris Ports (12 overlapping silicone layers)Ultrasonic, ½ Gal tank Static dissipative acrylic (ESD protective)Hi flow, 1 & 3 transducer systems Access door without portsCooling: ShelvesLiquid CO 2 or N 2 to Gas Metal-free work spaceThermoelectric: 100, 150, 200, 300, 400W Vibration-free configuration (external pumps)Heating: CartElectric: 250, 400, 500, & 800W 3 rd Parameter Monitoring

Requires linear sensor outputO2, CO 2, Pressure, ph etc.

Specifications:Material: Fans: (As required)

¼”, 3/8 ” (6, 9mm) clear & white acrylic 32 or 110 cfm (900 or 2700 l/min) ea.¼”, 3/8 ” ESD Acrylic: R s = 10 6 -10 9 Ω (specify 115 or 230 VAC)

Construction: Access Ports (As required):Acrylic: PS30 welded seams ¼” (6mm) hose barbs ESD Acrylic: solvent cement seams ¼” (6mm) quick disconnects

all panels bonded to GND 1” (25.4mm) hose barbsRTG: <1x10 9 Ω 3/8”, ½” (9, 12mm) compression fittings

Doors: 1½” (31.4mm) cable pass-through3/8 ” (12mm) clear acrylic, ½-turn latch(es) Dimensions (Max ):

Seal: 47”x47”x119” (120x120x302 cm)¼” (6mm) Poron, non-setting gasket Weight:

Operating Range (Function of operating systems): Determined by cabinet sizeHumidity: <5 – >80% Warranty:Temperature: <32 – 135 ° F (0-55 ° C) One (1) year

Specifications subject to change without notice 2/08