34
14/1 Siemens Industry, Inc. Industrial Controls Catalog Contents Pages Introduction System overview 6/2 AS-Interface specification 6/4 ASIsafe Introduction 6/6 AS-Interface safety monitors 6/8 AS-Interface safety modules 6/11 3SF1 position switches 6/14 Plastic enclosures 6/15 Metal enclosures 6/17 3SF1 Position switches with separate actuator 6/21 Plastic enclosures 6/22 Metal enclosures 6/23 Accessories 6/24 3SF1 Position switches with solenoid interlocking 6/25 Plastic enclosures 6/26 Metal enclosures 6/27 3SF1 hinge switches 6/28 Plastic enclosures 6/28 Metal enclosures 6/29 3SF2 Cable-operated switches for AS-Interface 6/30 SIRIUS EMERGENCY STOP mushroom pushbuttons for AS-Interface 6/31 AS-Interface F adaptors for EMERGENCY-STOP devices 6/34 Masters Masters for SIMATIC S7 6/35 CP 243-2 6/35 CP 343-2P, CP 343-2 6/36 Network transitions DP/AS-i LINK Advanced 6/38 DP/AS-Interface Link 20E 6/41 DP/AS-i F-Link 6/43 IE/AS-i LINK PN IO 6/47 Contents Pages Slaves I/O modules for operation in the field, high degree of protection 6/50 Digital I/O modules, IP67 – Introduction 6/50 Digital I/O modules, IP67 – K60 6/51 Digital I/O modules, IP68/IP69K – K60R 6/53 Digital I/O modules, IP67 – K45 6/55 Digital I/O modules, IP67 – K20 6/57 Digital I/O modules, IP67 – User modules 6/59 Analog I/O modules, IP67 – K60 6/60 I/O modules for operation in the control cabinet 6/63 Introduction 6/63 SlimLine 6/64 F90 module 6/66 Flat module 6/67 Special integrated solutions 6/68 AS-Interface communication modules 6/68 Modules with special functions 6/70 Counter modules 6/70 Ground-fault detection modules 6/71 Overvoltage protection module 6/71 AS-Interface connection for LOGO! 6/73 Contactors and contactor assemblies 6/74 SIRIUS 3RT20 contactors 6/74 SIRIUS 3RA24 contactor assemblies for wye-delta starting 6/75 SIRIUS 3RA27 function modules for AS-Interface 6/76 Motor starters for operation in the control cabinet 6/78 SIRIUS 3RA6 compact feeders 6/78 3RA61 direct-on-line starter 6/81 3RA62 reversing starter 6/82 Accessories 6/83 Add-on modules for AS-Interface 6/88 Infeed system for 3RA6 6/90 continued on next page Siemens complete AS-Interface offering is found in Section 6 of the Siemens IK PI 2012 Catalog In this section you will find the Table of Contents for Section 6 of the Siemens IK PI 2012 catalog and overview information on AS-Interface and ASIsafe. A PDF version of Section 6 on AS-Interface can be viewed from the Siemens’ on-line version of this 2014 Industrial Controls Catalog. Control Circuit Components AS-Interface, IO Link

Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

14/1Siemens Industry, Inc.Industrial Controls Catalog

Siemens / Industrial Controls Previous folio: new page

Contents Pages

IntroductionSystem overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/2AS-Interface specification . . . . . . . . . . . . . . . . . . . . . . . . 6/4

ASIsafeIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/6AS-Interface safety monitors . . . . . . . . . . . . . . . . . . . . . . 6/8AS-Interface safety modules . . . . . . . . . . . . . . . . . . . . . 6/113SF1 position switches . . . . . . . . . . . . . . . . . . . . . . . . . 6/14 Plastic enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/15 Metal enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/173SF1 Position switches with separate actuator . . . . . . 6/21 Plastic enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/22 Metal enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/23 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/243SF1 Position switches with solenoid interlocking . . . . 6/25 Plastic enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/26 Metal enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/273SF1 hinge switches . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/28 Plastic enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/28 Metal enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/293SF2 Cable-operated switches for AS-Interface . . . . . . 6/30SIRIUS EMERGENCY STOP mushroom pushbuttons for AS-Interface . . . . . . . . . . . . . . . . . . . . 6/31AS-Interface F adaptors for EMERGENCY-STOP devices . . . . . . . . . . . . . . . . . . . . . 6/34

MastersMasters for SIMATIC S7 . . . . . . . . . . . . . . . . . . . . . . . . 6/35CP 243-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/35CP 343-2P, CP 343-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/36

NetworktransitionsDP/AS-i LINK Advanced . . . . . . . . . . . . . . . . . . . . . . . . . 6/38DP/AS-Interface Link 20E . . . . . . . . . . . . . . . . . . . . . . . 6/41DP/AS-i F-Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/43IE/AS-i LINK PN IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/47

Contents Pages

SlavesI/O modules for operation in the field,high degree of protection . . . . . . . . . . . . . . . . . . . . . . . 6/50Digital I/O modules, IP67 – Introduction . . . . . . . . . . . . 6/50Digital I/O modules, IP67 – K60 . . . . . . . . . . . . . . . . . . 6/51Digital I/O modules, IP68/IP69K – K60R . . . . . . . . . . . . 6/53Digital I/O modules, IP67 – K45 . . . . . . . . . . . . . . . . . . 6/55Digital I/O modules, IP67 – K20 . . . . . . . . . . . . . . . . . . 6/57Digital I/O modules, IP67 – User modules . . . . . . . . . . 6/59Analog I/O modules, IP67 – K60 . . . . . . . . . . . . . . . . . . 6/60I/O modules for operation in the control cabinet . . . . . 6/63Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/63SlimLine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/64F90 module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/66Flat module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/67Special integrated solutions . . . . . . . . . . . . . . . . . . . . . 6/68AS-Interface communication modules . . . . . . . . . . . . . 6/68Modules with special functions . . . . . . . . . . . . . . . . . . 6/70Counter modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/70Ground-fault detection modules . . . . . . . . . . . . . . . . . . 6/71Overvoltage protection module . . . . . . . . . . . . . . . . . . . 6/71AS-Interface connection for LOGO! . . . . . . . . . . . . . . . 6/73Contactors and contactor assemblies . . . . . . . . . . . . . . 6/74SIRIUS 3RT20 contactors . . . . . . . . . . . . . . . . . . . . . . . 6/74SIRIUS 3RA24 contactor assemblies forwye-delta starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/75SIRIUS 3RA27 function modules for AS-Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/76Motor starters for operation in the control cabinet . . . . 6/78SIRIUS 3RA6 compact feeders . . . . . . . . . . . . . . . . . . . 6/78 3RA61 direct-on-line starter . . . . . . . . . . . . . . . . . . . . 6/81 3RA62 reversing starter . . . . . . . . . . . . . . . . . . . . . . . 6/82 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/83 Add-on modules for AS-Interface . . . . . . . . . . . . . . . 6/88 Infeed system for 3RA6 . . . . . . . . . . . . . . . . . . . . . . 6/90

continued on next page

Siemens complete AS-Interface offering is found in Section 6 of the Siemens IK PI 2012 Catalog .

In this section you will find the Table of Contents for Section 6 of the Siemens IK PI 2012 catalog and overview information on AS-Interface and ASIsafe.

A PDF version of Section 6 on AS-Interface can be viewed from the Siemens’ on-line version of this 2014 Industrial Controls Catalog.

Control Circuit ComponentsAS-Interface, IO Link

Page 2: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

14/2 Siemens Industry, Inc.Industrial Controls Catalog

Contents Pages

Motor starters for operation in the field,high degree of protection . . . . . . . . . . . . . . . . . . . . . . . 6/97SIRIUS M200D motor starters . . . . . . . . . . . . . . . . . . . 6/97 General data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/97 M200D motor starters for AS-Interface . . . . . . . . . . . 6/98 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/103SIRIUS MCU motor starters . . . . . . . . . . . . . . . . . . . . 6/107 General data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/107 MCU motor starters for AS-Interface . . . . . . . . . . . 6/109Motor starters for AS-Interface, 24 V DC . . . . . . . . . . 6/114SINAMICS G110D distributed converters . . . . . . . . . . 6/1173SF5 pushbuttons and indicator lights . . . . . . . . . . . . 6/121Enclosures and front panel modules for AS-Interface . . 6/121 General data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/121 With standard fittings . . . . . . . . . . . . . . . . . . . . . . . 6/122 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/123 Customized equipment . . . . . . . . . . . . . . . . . . . . . . 6/124 Front panel module . . . . . . . . . . . . . . . . . . . . . . . . . 6/1258WD4 signaling columns . . . . . . . . . . . . . . . . . . . . . . . 6/130

PowersupplyunitsanddatacouplingsAS-Interface power supply units . . . . . . . . . . . . . . . . . 6/135S22 .5 data decoupling modules . . . . . . . . . . . . . . . . . 6/136

TransmissionmediaAS-Interface shaped cables . . . . . . . . . . . . . . . . . . . . . 6/138

SystemcomponentsandaccessoriesRepeater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/139Extension Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/140Addressing units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/141Analyser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/143Other accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/146

SoftwareAS-Interface Function Block Library for SIMATIC PCS 7 . . . . . . . . . . . . . . . . . . . . . . . . . 6/149

CatalogNo.Prefix Description

3RA24 Contactor Assemblies for Wye-Delta Starting

3RA27 Contactor Function Modules for AS-Interface

3RA6 Compact Starter

3RG783 SIMATIC FS600 Laser Scanner

3RK11 Safety Monitor, Analog I/O Modules

3RK12 Compact Safety Modules, I/O Modules, Counter Modules, Communication Modules

3RK13 Enclosed Motor Starters

3RK14Compact Safety Modules, I/O Modules, Communication Modules, Ground Fault Protection Modules, Connections for LOGO!

3RK19 Accessories

3RK22 I/O Modules

3RK24 I/O Modules, Communication Modules

3RK27 ASI System Manual

3RK31 DP/AS-i F-Link

3RK43 MCU Enclosed Motor Starters

3RV19 Accessories for Compact Starter

3RX90 ASI Shaped Cables

3RX95 ASI Power Supplies

3S83 E-Stop Components

3SE50 Position Switches & Interlock Accessories

3SF1 Position Switches & Key Interlock Switches

3SF2 Cable Operated Switches

3SF54 F Adapters for E-Stops

3SF55 AS-i Slaves for Pilot Devices

3SF58 Pilot Device Stations, Front Panel Module

3SF59 Pilot Device Accessories

6GK12 Repeater/Extender

6GK14 DP/AS-i Links

6GK19 Manuals for SIMATIC S7 Masters

6GK7 Masters for SIMATIC S7

6SL35 SINAMICS G110D Drives

8WD4 Signal Columns

Control Circuit ComponentsAS-Interface

Page 3: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

14/3Siemens Industry, Inc.Industrial Controls Catalog

Contents Pages

IntroductionTransmission technology . . . . . . . . . . . . . . . . . . . . . . . . . 7/2Communication overview . . . . . . . . . . . . . . . . . . . . . . . . 7/3

MastersIO-Link master module for ET 200S . . . . . . . . . . . . . . . . 7/4 IO-Link 4SI electronic module4SI SIRIUS electronic module . . . . . . . . . . . . . . . . . . . . . 7/5 IO-Link master module for ET 200eco PN . . . . . . . . . . . 7/6

InputmodulesGeneral data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7/7IO-Link K20 modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7/8

ContactorsandcontactorassembliesSIRIUS 3RT20 contactors,3-pole, 3 . . . 30 HP . . . . . . . . . 7/9SIRIUS 3RA23 reversing contactor assemblies . . . . . . 7/11SIRIUS 3RA24 contactor assemblies for wye-delta starting . . . . . . . . . . . . . . . . . . . . . . . . . 7/13SIRIUS 3RA27 function modules for IO-Link . . . . . . . . 7/15

SIRIUS3RB2electronicoverloadrelays3RB24 for IO-Link, up to 630 A . . . . . . . . . . . . . . . . . . . 7/17 for high-feature applicationsAccessories for 3RB24 . . . . . . . . . . . . . . . . . . . . . . . . . 7/22

Contents Pages

SIRIUS3RA6compactfeedersSIRIUS 3RA64, 3RA65 compact feeders for IO-Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7/24Accessories for compact feeders for IO-Link . . . . . . . . 7/26

SIRIUS3UG48monitoringrelaysforstand-aloneinstallationforIO-LinkGeneral data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7/27Line monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7/29Voltage monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7/31Current monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7/32Power factor and active current monitoring . . . . . . . . . 7/33Speed monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7/35Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7/37

SIRIUS3RS14,3RS15temperaturemonitoringrelaysforIO-LinkGeneral data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7/38Relay, digitally configurable for 1 sensor . . . . . . . . . . . 7/40Relay, digitally configurable for up to 3 sensors . . . . . . 7/42Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7/44

Control Circuit ComponentsIO Link

Siemens complete IO-Link offering is found in Section 7 of the Siemens IK PI 2012 Catalog .

In this section you will find the Table of Contents for Section 7 of the Siemens IK PI 2012 catalog and overview information on IO-Link.

A PDF version of Section 7 on IO-Link can be viewed from the Siemens’ on-line version of this 2014 Industrial Controls Catalog.

Page 4: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

14/4 Siemens Industry, Inc.Industrial Controls Catalog

AS-InterfaceIntroduction

Communication overview

2/4 Siemens IC 10 N · 04/2013

2

OverviewAS-Interface is an open, international standard according to EN 50295 and IEC 62026-2 for process and field communication. Leading manufacturers of actuators and sensors all over the world support the AS-Interface. Interested companies are pro-vided with the electrical and mechanical specifications by the AS-Interface Association.

AS-Interface is a single master system. For automation systems from Siemens, there are communications processors (CPs) com-munications modules (CMs) and routers (links) that control the process or field communication as masters, and actuators and sensors that are activated as AS-Interface slaves.

BenefitsA key feature of AS-Interface technology is the use of a shared two-conductor cable for data transmission and the distribution of auxiliary power to the sensors/actuators. A power supply unit which meets the requirements of the AS-Interface transmission method and has an external data decoupling module if required is used for the distribution of auxiliary power. The AS-Interface cable used for the wiring is mechanically coded and hence pro-tected against polarity reversal and can be easily contacted by the insulation piercing method.

Elaborately wired control cables in the control cabinet and mar-shalling racks can be replaced by AS-Interface.

The AS-Interface cable can be connected to any points thanks to a specially developed cable and connection by the insulation piercing method.

With this concept you become extremely flexible and achieve high savings.

Application

I/O data exchangeThe AS-i master transmits automatically the inputs and outputs between the control system and the digital and analog AS-Interface slaves.

Slave diagnostics information is forwarded to the control system when required.

AS-Interface masters according to the AS-Interface Specifica-tion V2.1 or V3.0 support integrated analog value processing. This means that data exchange with analog AS-Interface slaves is just as easy as with digital slaves.

Command interfaceIn addition to I/O data exchange with binary and analog AS-Interface slaves the AS-Interface masters provide a number of other functions through the command interface.

Hence it is possible, for example, for slave addresses to be is-sued, parameter values transferred or configuration information read out from user programs.

You can find more information on the Internet, see http://support.automation.siemens.com/WW/view/en/51678777

Control andmonitoring system

Telecontrol and substation control

Remote access, e.g. via teleservice

Field device for intrinsically safe area

Coupler

Sensors

Field devices

Sensors Compactstarter

Compactstarter

Compactfeeder Field device

Power supply

Signalling column

Powersupply

1200

1242 7

Compactstarter

Protection and monitoring devices

PC/PG/IPC

PROFIBUS PA

Laptop

Motion ControlSystems

Notebook

SINAMICS

SIMOCODE

ASM456

PC

Security

AccessPoint

Link

AccessPoint

IWLAN

Database Server

ModuleControllerLOGO!

sevalSsevalS

AS-Interface

Link

AccessPoint

Link

Control andmonitoring system

Telecontrol and substation control

Remote access, e.g. via teleservice

Field device for intrinsically safe area

Coupler

Sensors

Field devices

Sensors Compactstarter

Field device

1200

1242 7

Compactstarter

Protection and monitoring devices

PC/PG/IPC

PROFIBUS PA

Laptop

Motion ControlSystems

Notebook

SINAMICS

SIMOCODE

ASM456

PC

Security

AccessPoint

Link

AccessPoint

IWLAN

Database Server

Module

AccessPoint

Link

G_I

K10

_XX

_200

02

IC10N_02_03.fm Page 4 Tuesday, December 17, 2013 9:02 PM

Siemens / Industrial Controls Previous folio: LV1 2/11, 14/5

As-InterfaceIntroduction

Communication overview

Page 5: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

14/5Siemens Industry, Inc.Industrial Controls Catalog

AS-InterfaceIntroduction

2/5Siemens IC 10 N · 04/2013

System components

2

OverviewTo implement communication, a system installation has the fol-lowing main components: • Master interface modules for central control units such as SI-

MATIC S7, ET 200 distributed peripherals, or routers from PROFIBUS/PROFINET to AS-Interface

• Power supply units, if required in combination with a data de-coupling module for the power supply to the slaves

• AS-Interface shaped cables

• Network components such as repeaters and extension plugs (cannot be used for AS-i Power24V)

• Modules for connection of standard sensors/actuators• Actuators and sensors with integrated AS-i slave• Safety modules for transmitting safety-oriented data through

AS-Interface• Addressing units for setting the slave addresses during com-

missioning

Example of a configuration with the system components

Features

24 V DCpower supply

AS-Interfacepower supply

AS-Interfacepower supply

Digital and analog K20, K45, K60 field modules

Safe position switch with door interlock

3RA2 load feeders

3RA6 compact starters

SIRIUS M200D motor starters or G110D frequency converters

Load feeders with safe AS-i outputs

Safe EMERGENCY-STOP and field module

Signaling columns

Pushbuttons Indicator lights

Safe and standard control cabinet modules S22.5 and S45

S7-1200 with CM 1243-2

DP/AS-i F-Link

SIMATIC/SIMOTION

DP/AS-i Link AdvancedDP/AS-i Link 20E

S7-300CP343-2(P)

PROFINET

AS-Interface

Industrial EthernetPROFIBUS DP

IE/AS-i Link PN IO

G_I

K10

_XX

_200

27j

S7-300CP343-2(P)

CM AS-i Master für ET 200SP

S7-200mit CP243-2

MSS ASIsafe

MSS Advanced

SINUMERIK

Standard EN 50295 / IEC 62026-2

Topology Line, star or tree structure (same as electrical wiring)

Transmission medium Unshielded two-wire cable (2 x 1.5 mm2) for data and auxiliary power

Connection methods Contacting of the AS-Interface cable by insulation piercing method

Maximum cable length • 100 m without repeater• 200 m with extension plug • 300 m with two repeaters in series connection • 600 m with extension plugs and two repeaters

connected in parallel Larger cable lengths are also possible when additional repeaters are connected in parallel

Maximum cycle time • 5 ms in full expansion with standard addresses• 10 ms in full expansion with A/B addresses,

profile-specific for Spec 3.0 slaves

Number of stations per AS-Interface line

• 31 slaves acc. to AS-Interface Spec. V2.0• 62 slaves (A/B technology) acc. to

AS-Interface Spec. V2.1 and V3.0• Integrated analog value transmission

Number of binary sensors and actuators

• Max. 124 DI/124 DO according to Spec. V2.0• Max. 248 DI/186 DO according to Spec. V2.1• Max. 496 DI/496 DO according to Spec. V3.0

Access control • Cyclic polling master/slave procedure• Cyclic data acceptance from host (PLC, PC)

Error safeguard Identification and repetition of faulty message frames

IC10N_02_03.fm Page 5 Tuesday, December 17, 2013 9:02 PM

Siemens / Industrial Controls Previous folio: LV1 2/12, 14/6

As-InterfaceIntroduction

System components

Page 6: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

14/6 Siemens Industry, Inc.Industrial Controls Catalog

AS-InterfaceIntroductionAS-Interface specificationSpecification 2.0, 2.1 and 3.0

2/6 Siemens IC 10 N · 04/2013

2

Overview

Scope of the AS-Interface specification

Basic data of AS-Interface Specification 2.0• AS-Interface Specification 2.0 describes a fieldbus system

with an AS-i master and up to 31 AS-i slaves. • Each AS-i slave has up to 4 digital inputs and 4 digital outputs. • With full expansion, the complete transmission of all input/out-

put data requires max. 5 ms cycle time.

Expansions of AS-Interface Specification 2.1AS-Interface Specification 2.1 enables the number of network stations to be doubled from 31 to 62 as follows: • The standard slaves continue to occupy one AS-i address

(1...31). • Slaves with extended addressing divide an address into an A

address (1A...31A) and a B address (1B...31B). Up to 62 A/B slaves can be connected accordingly to one AS-Interface network.

• Mixed operation of standard slaves and A/B slaves is possible without difficulty. The AS-i master identifies automatically which type of slave is connected. No special adjustments are required of the user.

Another function of the AS-Interface Specification V2.1 is the in-tegrated analog value transmission function. Access to both an-alog values and digital values is possible without the need for any special function blocks.

Expansions of AS-Interface Specification 3.0• AS-Interface Specification 3.0 enables the connection of

nearly 1000 digital inputs/outputs (profile S-7.A.A: 8DI/8DO as A/B slave).

• New profiles have also enabled the option of expanded ad-dressing for analog slaves.

• Acceleration of analog value transmission through "Fast Ana-log Profile".

• Variable use of analog modules: Optional parameterization of resolution (12/14 bit) and 1- and 2-channel capability.

• Asynchronous serial protocol 100 baud or 50 baud, bidirec-tional.

AS-Interface master for A/B slaves

To be able to operate A/B slaves on an AS-Interface network you must use master modules that meet the minimum requirements of Specification 2.1.

The AS-Interface specification relevant for the respective slave is noted in the "Selection and ordering data".

For the exact slave profile see AS-Interface system manual.

Communication cycle

Each address is queried in max. 5 ms cycle time. If two A/B slaves are operated on one basic address (e.g. 12A and 12B), a maximum 10 ms will be required for updating the data of both slaves.

All slave types can be mixed and used on a single AS-Interface network.More information, e.g. whether an AS-Interface slave is a stan-dard slave or an A/B slave, can be seen in the section "Selection and ordering data" or the "AS-Interface system manual".

More information

AS-Interface system manualMore information is available in the AS-Interface system manual.

The German AS-Interface system manual can be downloaded free of charge, see http://support.automation.siemens.com/WW/view/en/26250840

The English AS-Interface system manual can be downloaded free of charge, see http://support.automation.siemens.com/WW/view/en/26250840

A print version of the AS-Interface system manual is also avail-able under the following order number. • German 3RK2 703-3AB02-1AA1• English 3RK2 703-3BB02-1AA1

AS-Interface Specification Maximum number of slaves Number of digital inputs Number of digital outputsDigital Analog ASIsafe DI DO

Version 2.0 31 31 31 31 × 4 = 124 31 × 4 = 124

Version 2.1 62 31 31 62 × 4 = 248 62 × 3 = 186

Version 3.0 62 62 31 62 × 8 = 496 62 × 8 = 496

AS-Interface specification Available mastersVersion 2.1 CP 243-2 (S7-200)

Version 3.0 CP 343-2, 343-2P (S7-300 / ET 200M), DP/AS-i Link Advanced, DP/AS-i F-Link, DP/AS-Interface Link 20E, IE/AS-i Link PN IO, CM 1243-2 (S7-1200), CM AS-i Master ST for ET 200SP new

AS-Interface specification Maximum cycle time (digital signals)Version 2.0 5 ms

Version 2.1 5 ms with 31 slaves 10 ms with 62 slaves

Version 3.0 5 ms with 31 slaves10 ms with 62 slaves, supplementary, up to 20 ms with A/B slaves using 4DI/4DO, up to 40 ms with A/B slaves using 8DI/8DO

IC10N_02_03.fm Page 6 Tuesday, December 17, 2013 9:02 PM

≤ ×

Ωµ

Siemens / Industrial Controls Previous folio: LV1 2/13, 14/7

As-InterfaceIntroductionAS-Interface specificationSpecification 2.0, 2.1 and 3.0

Page 7: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

14/7Siemens Industry, Inc.Industrial Controls Catalog

IO-LinkIntroduction

2/17Siemens IC 10 N · 04/2013

Communication overview

2

OverviewIO-Link is an open communication standard for sensors and ac-tuators - defined by the Profibus User Organization (PNO). IO-Link technology is based on the point-to-point connection of sensors and actuators to the control system.

Parameter and diagnostics data are transmitted in addition to the cyclic operating data for the connected sensors/actuators. The simple, unshielded three-wire cable customary for standard sensors is used for this purpose.

Benefits

Engineering• Standardized, open system for greater flexibility (non-Siemens

IO-Link devices can be integrated in engineering)• Uniform, transparent configuring and programming through

integrated engineering (SIMATIC STEP 7)• Unassigned SIMATIC function blocks for easy parameteriza-

tion, diagnostics and read-out of measured values• Efficient engineering thanks to pre-integration into SIMATIC

HMI• Low error rate in CAD circuit diagram design as a result of

reduced control current wiring

Installation and commissioning• Faster assembly with minimized error rate as a result of re-

duced control current wiring• Less space required in the control cabinet• Low-cost circuitry where there are several feeders by making

full use of existing components

Operation and maintenance• High transparency in the system right down to field level and

integration into power management systems• Reduction in downtimes and maintenance times thanks to sys-

tem-wide diagnostics and faster fault correction• Support of predictive maintenance• Shorter changeover times, even for field devices, by means of

parameter and recipe management

ApplicationIO-Link can be used in the following main applications:• Easy connection of complex IO-Link sensors/actuators with a

large number of parameters and diagnostic data to the control system

• Replacement of sensor boxes for connecting binary sensors with the IO-Link input modules optimized in terms of cabling

• Optimized cable connection of switching devices to the con-trol system

• Simple transmission of energy values from the device to the control system for integration into a user program or power management

In these cases, all the diagnostics data are transmitted to the higher-level control system through IO-Link. The parameter set-tings can be changed during operation. Central data storage means that it is possible to exchange an IO-Link sensor/actuator without a PC or programming device.

Integration in STEP 7Integration of the device configuration in the STEP 7 environment guarantees: • Quick and easy engineering • Consistent data storage• Quick localization and rectification of faults

Control andmonitoring system

Telecontrol and substation control

Remote access, e.g. via teleservice

Field device for intrinsically safe area

Coupler

Sensors

Field devices

Sensors Compactstarter

IO-Link module

Compactstarter

Compactfeeder Field device

Signalling column

IO-Linkmaster

1200

1242 7

Compactstarter

Protection and monitoring devices

Protection and monitoring devices

PC/PG/IPC

PROFIBUS PA

Laptop

Motion ControlSystems

Notebook

SINAMICS

SIMOCODE

ASM456

PC

Security

AccessPoint

Link

AccessPoint

IWLAN

Database Server

ModuleControllerLOGO!

sevalSsevalS

AccessPoint

Link

Control andmonitoring system

Telecontrol and substation control

Remote access, e.g. via teleservice

Field device for intrinsically safe area

Coupler

starter

Compactstarter

Compactfeeder Field device

Signalling column

1200

1242 7

PC/PG/IPC

PROFIBUS PA

Laptop

Motion ControlSystems

Notebook

SINAMICS

SIMOCODE

ASM456

PC

Security

AccessPoint

Link

AccessPoint

IWLAN

Database Server

ModuleControllerLOGO!

Slaves Slaves

AccessPoint

Link

G_I

K10

_XX

_300

49

IC10N_02_12.fm Page 17 Tuesday, December 17, 2013 9:13 PM

IO-LinkIntroduction

Communication overview

Page 8: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

14/8 Siemens Industry, Inc.Industrial Controls Catalog

IO-LinkIntroduction

System components

2/18 Siemens IC 10 N · 04/2013

2

Overview

IO-Link product family

To implement communication, a system installation has the following main components: • An IO-Link master• Several IO-Link devices, usually sensors (RFID systems),

actuators or combinations of these• A standard 3-wire sensor/actuator cable

Example of a configuration with the system components

Standard sensors

Controller S7-300/S7-400

SIMATICET 200eco PN

with IO-Link master

ET 200SP (ET 200S)with IO-Link master

Actuators

Engineering and visualization

Visualization: SIMATIC HMIWinCC

IO-Link engineering: SIMATIC S7-PCT

SIRIUS3RA6 compact starters

K20 IO-Link module

SIRIUS3RA2 load feeders

with 3RA27 function modules

SIRIUS3RB24

overload relays

SIRIUS3RS14/3RS15 relays

Switching cabinet installation Field installation

RFID systemRF200

RFID systemRF200

SIRIUS contactor 3RT2 with SIRIUS 3RR24 relay

SIRIUS

relay3UG48

PROFINET

IO-Link

IK10

_301

41b

IC10N_02_12.fm Page 18 Tuesday, December 17, 2013 9:13 PM

Siemens / Industrial Controls Previous folio: LV1 2/14, 14/8

Product Category: AS-Interface

IO-LinkIntroduction

System components

Page 9: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

14/9Siemens Industry, Inc.Industrial Controls Catalog

Siemens / Industrial Controls Previous folio: LV1T 2/106 & LV1 2/74

Product Category: AS-Interface

IO-LinkIntroduction

2/19Siemens IC 10 N · 04/2013

System components

2

Compatibility of IO-LinkIO-Link guarantees compatibility between IO-Link-capable modules and standard modules as follows: • IO-Link sensors can be operated both on IO-Link modules

(masters) and standard input modules.• IO-Link sensors/actuators as well as today's standard sen-

sors/actuators can be used on IO-Link masters.• If conventional components are used in the IO-Link system,

then of course only the standard functions are available at this point.

Analog signalsAnother advantage of IO-Link technology is that analog signals are digitized already in the IO-Link sensor itself and are digitally transmitted by the IO-Link communication. As the result, faults are prevented and there is no extra cost for cable shielding.

Enhanced through IO-Link input modulesIO-Link compatibility also permits connection of standard sen-sors/actuators, i.e. conventional sensors/actuators can also be connected to IO-Link. This is particularly effective with the IO-Link input modules, which allow several sensors to be con-nected at one time via a cable to the controller.

Load feeders and motor startersThrough IO-Link it is possible to control not only sensors but also actuators in the form of load feeders and motor starters.

Possibilities for connecting load feeders and motor starters to IO-Link or in the conventional way

Grouping of motor startersThe SIRIUS controls allow four starters to be combined to form a group.

Connection of a motor starter group made up of three 3RA64 direct-on-line starters and a 3RA65 reversing starter

In this way up to 16 starters can be operated on a single IO-Link master. This leads to a reduction in the installation space and control wiring required.

srosneSsrosneS Actuators Actuators

Point-to-pointconnection through IO-Link

Classicwiring

ET 200S with digital I/O modules

K20Sensorbox

ET 200SP (ET 200S)with IO-Link master

NS

A0_

0048

9c

IC10N_02_12.fm Page 19 Tuesday, December 17, 2013 9:13 PM

IO-LinkIntroduction

System components

Page 10: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

14/10 Siemens Industry, Inc.Industrial Controls Catalog

IO-LinkIntroduction

System components

2/20 Siemens IC 10 N · 04/2013

2

Overload and monitoring relaysBy combining overload/monitoring relays with IO-Link it is now possible to send data that has already been recorded and

evaluated in the monitoring relays directly to the controller. This avoids the use of duplicated sensors.

Possibilities for connecting overload relays to IO-Link or in the conventional way

Wireless communicationUsing an upstream IWLAN client module, such as SCALANCE W746-1PRO, allows IO-Link to be be integrated into the PROF-INET world via a distributed I/O. Possible uses include acting as an alternative to fault-prone cable carrier or collector wire tech-nology. The individual diagnostics options offered by

the various IO-Link devices provide greater transparency for the production process. Just like the parameter data for a device, these diagnostics data can be evaluated remotely using the possibilities offered by SIMATIC. This supports remote mainte-nance down to the lowest level in the field.

Wireless communication between Industrial Ethernet and IO-Link components

3

1 22

1

1

Feeder

PLC

Motor

Monitoring relay3UG46

Monitoring relay3UG46

Monitoring relay3UG46

Analog signal

converter

Current transfor-

mers

Signaling of limit value violation plus measurement data transmission to PLCAutonomous operation without PLCSignaling of limit value violation to PLC

1

2

PLC

IO-Link master

Monitoring relay 3UG48

Monitoring relay 3UG48

Monitoring relay 3UG48 Feeder

Motor

Signaling of limit value violation plus measurement data transmission to PLCAutonomous operation without PLC

1

23

IC01

_001

75

IO-Link

Pump station Maintenance station

Control room

Compact starter3RA6

ET 200SP (ET 200S)with IO-Link master

IC01

_001

98a

Industrial Ethernet

IO-Link

SCALANCE W784 Access Point

SIMATIC HMI KTP 1500 Basic

SIMATICS7-300

SCALANCE W786-xPRO Outdoor Access Point

IC10N_02_12.fm Page 20 Tuesday, December 17, 2013 9:13 PM

Siemens / Industrial Controls Previous folio: LV1T 2/108 & LV1T 2/109

IO-LinkIntroduction

System components

Page 11: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

14/11Siemens Industry, Inc.Industrial Controls Catalog

IO-LinkIntroduction

2/21Siemens IC 10 N · 04/2013

System components

2

IO-Link components

1) http://support.automation.siemens.com/DE/view/en/37936752 2) http://support.automation.siemens.com/DE/view/en/38487085 3) http://support.automation.siemens.com/DE/view/en/38006560 4) http://support.automation.siemens.com/DE/view/en/29801139/133100

IO-Link master, software, cables

CM 4x IO-Linkfor ET 200SP

MastersIO-Link master modules for ET 200SP

• CM 4x IO-Link

IO-Link master modules for ET 200S

• IO-Link 4SI electronic module

• SIRIUS 4SI electronic modules

IO-Link master modules for ET 200eco PN

Software

STEP 7 PCT

STEP 7 PCTEngineering software for configuring the IO-Link master modules for ET 200SP, ET 200S and ET 200eco

• Available as a stand-alone version or integrated into STEP 7 (Version 5.5 SP1 or later)

• Retrieving parameter and diagnostics data from the IO-Link devices connected to the master

• Monitoring of the process image of the IO-Link devices

• Open interface for importing further IODDs

• Freely available for download from Industry Online Support1)

IO-Link Call function block

IO-Link Call function blockSTEP 7 function block for easy acyclical data exchange in the user program

• Freely available for download from Industry Online Support2)

WinCC flexible template project

WinCC flexible template projectEasy integration of IO-Link devices into the user pro-gram by using ready-made WinCC flexible templates

• Freely available for download from Industry Online Support3)

IODD filesIO-Link Device Description (IODD) files provide the device description for IO-Link

• Comprehensive IODD catalog of SIEMENS IO-Link devices

• Freely available for download from Industry Online Support4)

Cable3-wire standard cable

IO-Link devices

K20 input module

Detection with IO-LinkIO-Link input modulesK20 input module

• 4 inputs, M12 connections

• 8 inputs, standard M8 connections

BOOL

IOL_CALL

DWORDINT

DONEBUSY

INTINT

NEL_DRTNI

INTANY

BOOLERROR

IOL_STATUSSTATUS

BOOLBOOL

INT

BOOL

DWODWO

REQ

IDCAP

PORTIOL_INDEXIOL_SUBINDEX

LENRECORD_IOL_DATA

RD_WR

IC01_00197

IO-Link devices (continued)

SIMATIC RF210R,SIMATIC RF220R, SIMATIC RF260R

IO-Link RFID systemsSIMATIC RF200 RFID system in the HF range• SIMATIC RF210R, SIMATIC RF220R,

SIMATIC RF260R products• Simple identification tasks (read-only), such as

reading an ID number• No RFID-specific programming, ideal for those

new to RFID• Simple connection via master modules for IO-Link,

such as SIMATIC ET 200S and ET 200eco• Use with the tried and tested ISO 15693 transponders

(MOBY D)

Switching with IO-Link

SIRIUS 3RA27 11 function module for IO-Link

Contactors and contactor assembliesPower contactors for switching motors• SIRIUS 3RT2 contactors, 3-pole, up to 18.5 kW• Contactor assemblies• SIRIUS 3RA23 reversing contactor assemblies• SIRIUS 3RA24 contactor assemblies for wye-delta

starting• SIRIUS 3RA27 function modules for IO-Link• For direct-on-line starters, reversing starters and

wye-delta starters

See chapter 2

SIRIUS 3RA64 direct-on-line starter

Motor starters for use in the control cabinetSIRIUS 3RA6 compact starters• 3RA64 direct-on-line starters• 3RA65 reversing starters• Infeed systems for 3RA6

See chapter 4

Contactors with IO-Link

SIRIUS 3RB24 overload relays

Overload relaysSIRIUS 3RB24 solid-state overload relays for IO-Link• Evaluation module• Current measuring modules from 0.3 to 630 A• Controlling direct-on-line, reversing and star-delta

starters via IO-Link in conjunction with contactors• Full motor protection• Diagnostics and current value transmission via IO-Link

See chapter 3

Monitoring with IO-Link

SIRIUS 3UG48 monitoring relays

Monitoring relaysSIRIUS 3UG48 monitoring relays for IO-Link • Monitoring voltage, current, power, speed or p.f.

according to device design• ON-delay and tripping delay time can be adjusted

See chapter 11

SIRIUS 3RS14 temperature moni-toring relays

SIRIUS 3RS14, 3RS15 temperature monitoring relays for IO-Link• Temperature monitoring with connected sensors• Two limit values, can be adjusted separately

See chapter 11

SIRIUS 3RR24 monitoring relays

SIRIUS 3RR24 monitoring relays for IO-Link• Monitoring of current, phase failure, open circuit and

phase sequence • Designed for mounting on 3RT2 contactors

See chapter 2

IC10N_02_12.fm Page 21 Tuesday, December 17, 2013 9:13 PM

≤ ×

Ωµ

IO-LinkIntroduction

System components

Page 12: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

14/12 Siemens Industry, Inc.Industrial Controls Catalog

IO-LinkIntroduction

IO-Link specification

2/22 Siemens IC 10 N · 04/2013

2

Overview

Principles of the IO-Link specificationAccording to the IO-Link specification, communication functions as follows: • Transmission takes place via an unshielded three-wire cable

no more than 20 m long, of the kind normally used for standard sensors.

• Analog values which have already been digitized are transmit-ted in the form of message frames, which may correspond to +/- 10 V or 4 to 20 mA.

• Digital communication from 0 to 24 V on the so-called C/Q cable

• Most of the values transmitted are measured values from the sensors which include the units.

• The sensors and actuators are described by the IO-Link Device Description (IODD).

• While the IO-Link specification permits an infinite number of ports, an IO-Link master currently only supports four ports. Only one IO-Link device (slave) can be connected to each port (point-to-point connection).

• Transmission parameters between IO-Link master and the de-vices: 1 start bit. 8 data bits, 1 parity bit and 1 stop bit.

• The transmission rates between IO-Link master and the de-vices are as follows:- via COM1: 4 800 bps - via COM2: 38 400 bps - via COM3: 230 400 bps

• The average cycle time is 2 ms for the reading/writing of 16 data bits at a transmission rate of 38 400 bps.

IO-Link protocolFor the dialog between device and master, IO-Link uses a stan-dard protocol, the standard asynchronous communication inter-face (UART) in "semi-duplex" mode.

The IO-Link protocol supports both the Standard IO mode (SIO) and the IO-Link communication mode (COM).

The structure of the protocol and its message frames depends on the types of data to be transmitted.

Data typesIn the IO-Link specification a distinction is made between the fol-lowing data types:

Process data

The process data of the devices are transmitted cyclically in a data frame, provided the process data width does not exceed 2 bytes. In the case of larger process data widths up to 32 bytes, parts are transmitted one after the other in several cycles. As of Version V1.1 of the specification, up to 32 bytes of process data can be transferred in a single cycle.

Service data (SD)

With the aid of the service data, parameter values or device sta-tuses can be read out. It is also possible to write the parameter values or transmit commands via the service data. Service data are always exchanged acyclically and in response to an inquiry from the IO-Link master.

Events

Via events it is possible to transmit device events or statuses such as contamination, overheating, short circuits etc., from the the device via the IO-Link master to the PLC or to visualize them.

The events are sent on the initiative of the devices via the "event flag", which the master evaluates. The master itself can also gen-erate events.

Three categories of event are defined:• Error signals (errors)• Maintenance data (warnings)• Device functions (notifications)

M-sequence (message frames)Parameter data, events and process data can be transmitted ei-ther in an M-sequence (message frame) or in separate M-se-quences (message frame).

Data storageAs of Specification V1.1, a data storage concept has been cre-ated for IO-Link. In this concept, the IO-Link device initiates the storage of its data on a higher-level parameter server. In the event that a device is replaced, the parameter server can restore the original parameterization. It is therefore possible to replace the devices without re-parameterization.

The IO-Link master can contain the parameter server. The pa-rameter server can also be implemented centrally in the PLC or in a system server. In this case the IO-link master passes on the corresponding information.

IO-Link masterThe IO-Link master is the interface to higher-level control sys-tems. The IO-Link master presents itself as a normal fieldbus node, and is integrated into the appropriate network configurator via the relevant device description (e. g. GSD, FDCML, EDS etc.).

IO-Link Device Description (IODD)The IO-Link Device Description (IODD) has been defined to pro-vide a full, transparent description of system characteristics as far as the IO-Link device. It is based on the open XML standard.

The IODD contains information on communication characteris-tics, device parameters, identification, process and diagnostics data, and is supplied by the manufacturer. The design of the IODD is the same for all devices from all manufacturers, and is always presented in the same way by the IODD Interpreter Tools. This therefore ensures that the handling is the same for all IO-Link devices, whatever the manufacturer.

New in IO-Link specification 1.1The IO-Link specification is currently available in Version 1.1, and is currently standardized as IEC 61131-9 (CDV).

Specification 1.1 offers the following new features compared with the previous specification 1.0:• New variable M-sequences allow transmission of up to 32

bytes of process or service data in a single cycle.• Data storage concept

IO-Link master

Interface hardware:compatible with sensors according to IEC 60947-5-2 and actuatorsCommunication and switching possible alternately

IO-Link device

IC01

_001

76

41

L+

C/Q

L–

23

SIOStandard IOswitching operation

SIO / IO-Link

COMSerial, bidirectional communication

IC10N_02_12.fm Page 22 Tuesday, December 17, 2013 9:13 PM

IO-LinkIntroduction

IO-Link specification

Page 13: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/1Siemens Industry, Inc.Industrial Controls Catalog

Siemens / Industrial Controls Previous folio: 15/1

Contents Pages

LOGO!ProgrammableRelaysIntroduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15/2

LOGO!ModularBasicVariantsLOGO!.24,.12/24RC,.24RC,.230RC . . . . . . . . . . . 15/3.-.15/4

LOGO!ModularPureVariantsLOGO!.24Co,.12/24RCo,.24RCo,.230RCo. . . . . 15/5.-.15/64

LOGO!ModularExpansionModulesLOGO!.DM8.24,.DM8.12/24R,.DM8.24R,.DM8.230R. . 15/7LOGO!.DM16.24,.DM16.24R,.DM16.230R. . . . . . . . . . 15/7LOGO!.AM2,.AM2.PT100. . . . . . . . . . . . . . . . . . . . . . . . 15/7

LOGO!Contact&LOGO!TD. . . . . . . . . . . . . . . . . . . . 15/8

LOGO!Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15/9.

LOGO!Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15/10

SITOPPowerSupplies&PowerSecurityComponentsIntroduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15/11

Low.Wattage,.Single.Phase.Power.Supplies.. (15.-.96.Watts). . . . . . . . . . . . . . . . . . . . . . . . 15/12.-.15/13

Basic,.Single.Phase.Power.Supplies.. (36.-.300.Watts). . . . . . . . . . . . . . . . . . . . . . . 15/14.-.15/15

Standard,.Single.Phase.Power.Supplies... (60.-.960.Watts). . . . . . . . . . . . . . . . . . . . . . . 15/16.-.15/17

Standard,.Three.Phase.Power.Supplies.. (120.-.960.Watts). . . . . . . . . . . . . . . . . . . . . . 15/18.-.15/19

Special.design.power.supplies.in.Single.. and.Three.Phase.(30.-.720.Watts). . . . . . . . . 15/20.-.15/21

Expansion.Modules:.Signaling,.Redundancy,.. Buffer,.&.Diagnostic.Modules. . . . . . . . . . . . . . . . . . 15/22

DC.Uninterruptible.Power.Supplies . . . . . . . . . 15/23.-.15/26

SIMATICNetEthernet.Infrastructure.Components.Overview. . . . . . 15/27

LOGO! Logic Module & SITOP Power Supplies

Page 14: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/2 Siemens Industry, Inc.Industrial Controls Catalog

Further information see Siemens Catalog ST 70 Further information about LOGO! Logic Module on the internet: www.siemens.com/logo

Siemens / Industrial Controls Previous folio: ST-70 2013 pg2-2

Overview

LOGO! logic module• The compact, easy-to-use and low-cost solution for simple

control tasks• Compact, easy to operate, universally applicable without

accessories• "All in one": Integrated display and operator panel• 36 different functions can be connected at the click of a button

or by means of PC software; up to 130 times over • Functions are easily changed at the press of a key.

No more time-consuming rewiring

LOGO! logic moduleIntroduction

LOGO! logic module

Page 15: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/3Siemens Industry, Inc.Industrial Controls Catalog

LOGO! modular basic variants

Siemens / Industrial Controls Previous folio: ST-70 2013 pg2-3 & 2-4

Further information see Siemens Catalog ST 70 Further information about LOGO! Logic Module on the internet: www.siemens.com/logo

LOGO! logic moduleLOGO! modular

Overview • The space-saving basic variants• Interface for the connection of expansion modules, up to

24 digital inputs, 16 digital outputs, 8 analog inputs and 2 analog outputs can be addressed

• With connection option for LOGO! text display TD(can be connected to all LOGO! 0BA6 basic variants)

New in LOGO! 0BA7 variants:• Ethernet interface for communication with SIMATIC Controller,

SIMATIC Panel and PC• Networking of max. 8 LOGO! devices• Use of standard SD card or SIMATIC memory card

Ordering data .oNredrO.oNredrO

LOGO! logic module 24C 6ED1 052-1CC01-0BA624 V DC power supply, 8x 24 V DC digital inputs, of which 4 can be used in analog mode (0 to 10 V), 4x 24 V DC digital outputs, 0.3 A, integral time switch; 200 function blocks can be inter-linked,modular expansion capability

LOGO! logic module 12/24RC 6ED1 052-1MD00-0BA612/24 V DC power supply, 8x 12/24 V DC digital inputs, of which 4 can be used in analog mode (0 to 10 V)4x 10 A relay outputs, integral time switch; 200 function blocks can be inter-linked,modular expansion capability

LOGO! logic module 24RC 6ED1 052-1HB00-0BA624 V AC/DC power supply, 8x 24 V AC/DC digital inputs, 4x 10 A relay outputs, integral time switch; 200 function blocks can be inter-linked,modular expansion capability

LOGO! logic module 230RC 6ED1 052-1FB00-0BA6115/230 V AC/DC power supply, 8x 115/230 V AC/DC digital inputs, 4x 10 A relay outputs, integral time switch; 200 function blocks can be inter-linked, modular expansion capability

LOGO! logic module 12/24RCE 6ED1 052-1MD00-0BA712/24 V DC power supply, 8x 12/24 V DC digital inputs, of which 4 can be used in analog mode (0 to 10 V)4x 10 A relay outputs, integral time switch; 400 function blocks can be inter-linked,Ethernet interface,modular expansion capability

LOGO! logic module 230RCE 6ED1 052-1FB00-0BA7115/230 V AC/DC power supply, 8x 115/230 V AC/DC digital inputs, 4x 10 A relay outputs, integral time switch; 400 function blocks can be inter-linked, Ethernet interface, modular expansion capability

Page 16: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/4 Siemens Industry, Inc.Industrial Controls Catalog

Ordering data Order No. Order No.AccessoriesLOGO! TD text display 6ED1 055-4MH00-0BA04-line text display, can be con-nected to all LOGO! 0BA6 Basic and Pure versions, including con-necting cable

LOGO! ManualGerman 6ED1 050-1AA00-0AE8English 6ED1 050-1AA00-0BE8French 6ED1 050-1AA00-0CE8Spanish 6ED1 050-1AA00-0DE8Italian 6ED1 050-1AA00-0EE8Chinese 6ED1 050-1AA00-0KE8LOGO! Memory Card 6ED1 056-1DA00-0BA0Program module for copying, with know-how protection

LOGO! battery card 6ED1 056-6XA00-0BA0Battery module for backingup the integral real-time clock (not LOGO! 24)

LOGO! memory/battery card 6ED1 056-7DA00-0BA0Combined program and battery module, with know-how protection and for backing up the integral real-time clock (not LOGO! 24)

LOGO! PROM 6AG1 057-1AA01-0BA6Programming device used to simul-taneously reproduce program mod-ule contents on up to 8 program modules

LOGO!Soft Comfort V7.0 6ED1 058-0BA02-0YA1For programming on the PC inLAD/FBD; executes on Windows 7, VISTA, XP, NT4.0, 2000, 98SE, Linux and MAC OSX; on CD-ROM

LOGO!Soft Comfort V7.0 upgrade 6ED1 058-0CA02-0YE1Upgrade from V1.0 to V7.0

LOGO! PC cable 6ED1 057-1AA00-0BA0For program transfer between LOGO! and the PC

LOGO! USB PC cable 6ED1 057-1AA01-0BA0For transferring the program between LOGO! and PC, including driver on CD-ROM

LOGO! modem cable 6ED1 057-1CA00-0BA0Adapter cable for analog modem communication

Front panel mounting setWidth 4 MW 6AG1 057-1AA00-0AA0Width 4 MW, with keys 6AG1 057-1AA00-0AA3Width 8 MW 6AG1 057-1AA00-0AA1Width 8 MW, with keys 6AG1 057-1AA00-0AA2

Siemens / Industrial Controls Previous folio: 15/14

Further information see Siemens Catalog ST 70 Further information about LOGO! Logic Module on the internet: www.siemens.com/logo

LOGO! logic moduleLOGO! modular

LOGO! modular basic variants

Page 17: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/5Siemens Industry, Inc.Industrial Controls Catalog

Siemens / Industrial Controls Previous folio: 15/15

Further information see Siemens Catalog ST 70 Further information about LOGO! Logic Module on the internet: www.siemens.com/logo

LOGO! logic moduleLOGO! modular

Overview • The cost-optimized basic variants• Interface for the connection of expansion modules, up to

24 digital inputs, 16 digital outputs, 8 analog inputs and2 analog outputs can be addressed

• With connection option for LOGO! TD text display(can be connected to all LOGO! 0BA6 basic variants)

Ordering data .oNredrO.oNredrO

LOGO! logic module 24Co 6ED1 052-2CC01-0BA624 V DC power supply, 8 digital inputs 24 V DC, of which 4 can be used in analog mode (0 to 10 V), 4 digital outputs 24 V DC, 0.3 A, integrated time switch; without display and keyboard; 200 function blocks can be inter-linked,modular expansion capability

LOGO! logic module 12/24RCo 6ED1 052-2MD00-0BA612/24 V DC power supply, 8 digital inputs 12/24 V DC,of which 4 can be used in analog mode (0 to 10 V), 4 relay outputs 10 A, integral time switch; without display and keyboard; 200 function blocks can be inter-linked,modular expansion capability

LOGO! logic module 24RCo 6ED1 052-2HB00-0BA624 V AC/DC power supply, 8 digital inputs 24 V AC/DC, 4 relay outputs 10 A, integral time switch; without display and keyboard; 200 function blocks can be inter-linked,modular expansion capability

LOGO! logic module 230RCo 6ED1 052-2FB00-0BA6115/230 V AC/DC power supply, 8 digital inputs 115/230 V AC/DC, 4 relay outputs 10 A, integral time clock; without display and keyboard; 200 function blocks can be inter-linked,modular expansion capability

AccessoriesLOGO! TD text display 6ED1 055-4MH00-0BA04-line text display, can be connected to all LOGO! 0BA6 Basic and Pure versions, including con-necting cable

SIPLUS LOGO! TD text display 6AG1 055-4MH00-2BA0(extended temperature range-10 ... +60 °C and medial loading)

4-line text display, can be connected to all LOGO! 0BA6 Basic and Pure versions, including con-necting cable

LOGO! ManualGerman 6ED1 050-1AA00-0AE8English 6ED1 050-1AA00-0BE8French 6ED1 050-1AA00-0CE8Spanish 6ED1 050-1AA00-0DE8Italian 6ED1 050-1AA00-0EE8Chinese 6ED1 050-1AA00-0KE8LOGO! Memory Card 6ED1 056-1DA00-0BA0Program module for copying, with know-how protection

LOGO! battery card 6ED1 056-6XA00-0BA0Battery module for backing up the integral real-time clock(not LOGO! 24)

LOGO! modular pure variants

Page 18: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/6 Siemens Industry, Inc.Industrial Controls Catalog

Siemens / Industrial Controls Previous folio: 15/16

Further information see Siemens Catalog ST 70 Further information about LOGO! Logic Module on the internet: www.siemens.com/logo

LOGO! logic moduleLOGO! modular

Selection and ordering data (continued)

LOGO! memory/battery card 6ED1 056-7DA00-0BA0Combined program and battery module, with know-how protection and for backing up the integral real-time clock (not LOGO! 24o)

LOGO! PROM 6AG1 057-1AA01-0BA6Programming device used to simul-taneously reproduce program module contents on up to 8 program modules

LOGO!Soft Comfort V7.0 6ED1 058-0BA02-0YA1For programming on the PC in LAD/FBD; executes on Windows 7, VISTA, XP, NT4.0, 2000, 98SE, Linux and MAC OSX; on CD-ROM

LOGO!Soft Comfort V7.0 upgrade 6ED1 058-0CA02-0YE1Upgrade from V1.0 to V7.0

LOGO! PC cable 6ED1 057-1AA00-0BA0For program transfer between LOGO! and the PC

LOGO! USB PC cable 6ED1 057-1AA01-0BA0For transferring the program between LOGO! and PC, including driver on CD-ROM

LOGO! modem cable 6ED1 057-1CA00-0BA0Adapter cable for analog modem communication

LOGO! Starter kits (0BA6)LOGO! TD Starter kitLanguage-neutral with LOGO! 12/24RCo + LOGO! TD

6ED1 057-3BA10-0AA6

LOGO! modular pure variants

Page 19: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/7Siemens Industry, Inc.Industrial Controls Catalog

LOGO! logic moduleLOGO! modular

2/14

Overview • Expansion modules for connection to LOGO! modular• With digital inputs and outputs, analog inputs, or analog

outputs

Ordering data .oNredrO.oNredrO

LOGO! DM8 24 6ED1 055-1CB00-0BA0Supply voltage 24 V DC, 4 digital inputs 24 V DC, 4 digital outputs 24 V DC, 0.3 A

LOGO! DM16 24 6ED1 055-1CB10-0BA0Supply voltage 24 V DC, 8 digital inputs 24 V DC,8 digital outputs 24 V DC, 0.3 A

LOGO! DM8 12/24R 6ED1 055-1MB00-0BA1Supply voltage 12/24 V DC, 4 digital inputs 12/24 V DC, 4 relay outputs 5 A

LOGO! DM8 24R 6ED1 055-1HB00-0BA0Supply voltage24 V AC/DC,4 digital inputs 24 V AC/DC, 4 relay outputs 5 A

LOGO! DM16 24R 6ED1 055-1NB10-0BA0Supply voltage 24 V DC,8 digital inputs 24 V DC,8 relay outputs 5 A

LOGO! DM8 230R 6ED1 055-1FB00-0BA1Supply voltage 115/230 V AC/DC, 4 digital inputs 115/230 V AC/DC, 4 relay outputs 5 A

LOGO! DM16 230R 6ED1 055-1FB10-0BA0Supply voltage 115/230 V AC/DC, 8 digital inputs 115/230 V AC/DC, 8 relay outputs 5 A

LOGO! AM2 6ED1 055-1MA00-0BA0Supply voltage 12/24 V DC,2 analog inputs 0 ... 10 V or 0 ... 20 mA, 10-bit resolution

LOGO! AM2 PT 100 6ED1 055-1MD00-0BA1Supply voltage 12/24 V DC, 2 analog inputs Pt100, temperature range -50 °C ... 200 °C

LOGO! AM2 AQ 6ED1 055-1MM00-0BA1Supply voltage 24 V DC, 2 analog outputs 0 to 10 V, 0/4 to 20 mA

AccessoriesLOGO! ManualGerman 6ED1 050-1AA00-0AE8English 6ED1 050-1AA00-0BE8French 6ED1 050-1AA00-0CE8Spanish 6ED1 050-1AA00-0DE8Italian 6ED1 050-1AA00-0EE8Chinese 6ED1 050-1AA00-0KE8LOGO! Memory Card 6ED1 056-1DA00-0BA0for copying, with know-how protection

LOGO!Soft Comfort V7.0 6ED1 058-0BA02-0YA1For programming on the PC in LAD/FBD; executes on Windows 7, VISTA, XP, NT4.0, 2000, 98SE, Linux and MAC OSX; on CD-ROM

LOGO!Soft Comfort V7.0 upgrade 6ED1 058-0CA02-0YE1Upgrade from V1.0 to V7.0

LOGO! PC cable 6ED1 057-1AA00-0BA0For program transfer between LOGO! and the PC

Further information see Siemens Catalog ST 70 Further information about LOGO! Logic Module on the internet: www.siemens.com/logo

LOGO! modular expansion modules

Page 20: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/8 Siemens Industry, Inc.Industrial Controls Catalog

LOGO! logic moduleLOGO! modular

Overview Ordering Data Order No.

• Switching module for the direct switching of resistive loads and motors

• 4-line backlit LCD, 128x64 pixel resolution• 24 VDC/VAC input voltage, includes connecting cable (2.5M)

& mounting hardware• 6 screen navigation keys and 4 user function buttons• Power-on screen and backlight activate function• Text, numeric display and timer/counter set point changes• Advanced bar-graph and text ticker features

LOGO!ContactModule for direct switching of resistive consumers up to 20 A and motors up to 4 kW

Switching voltage 24 V 6ED10574CA000AA0Switching voltage 230 V 6ED10574EA000AA0

LOGO! TD Text Display 6ED10554MH000BA0

Further information see Siemens Catalog ST 70 Further information about LOGO! Logic Module on the internet: www.siemens.com/logo

LOGO! contact & LOGO! TD

Page 21: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/9Siemens Industry, Inc.Industrial Controls Catalog

Overview

The flat power supply unit for distribution boardsThe new miniature power supply units now offer even greater performance in the smallest space: The efficiency has been improved across the entire load range, and the power loss in

no-load operation has been cut in half. The wide-range input now also allows operation with direct voltage, the switch-on behavior has been optimized for capacitive loads, and the operating temperature range has been extended to +70 °C. The power supplies with logic module design can be used extremely flexibly in numerous applications – thanks to their flat, stepped profile in distribution boards, for example.

Essential product features• 2 performance classes, each with 5 V, 12 V, and 15 V• 3 performance classes with 24 V• Flat LOGO! design• Wide-range input for 85 V to 264 V AC or 110 V to 300 V DC• Constant current for connection of loads with high inrush

current• Power reserve on starting up through 1.5 times the rated

current for capacitive loads• Adjustable output voltage• Green LED for "Output voltage OK"• Temperature range from –20 °C to +70 °C• Comprehensive certification, e.g. ATEX and GL

Ordering data .oNredrO.oNredrO

LOGO!Power 5 VStabilized power supply; output: 5 V DC/3 A• Input rated value:

100 … 240 V AC; extended operating temperature range: up to +70 °C

6EP1 311-1SH03

Stabilized power supply; output: 5 V DC/6.3 A• Input rated value:

100 … 240 V AC; extended operating temperature range: up to +70 °C

6EP1 311-1SH13

LOGO!Power 12 VStabilized power supply; output: 12 V DC/1.9 A• Input rated value:

100 … 240 V AC; extended operating temperature range: up to +70 °C

6EP1 321-1SH03

Stabilized power supply; output: 12 V DC/4.5 A• Input rated value:

100 … 240 V AC; extended operating temperature range: up to +70 °C

6EP1 322-1SH03

LOGO!Power 15 VStabilized power supply; output: 15 V DC/1.9 A• Input rated value:

100 … 240 V AC; extended operating temperature range: up to +70 °C

6EP1 351-1SH03

Stabilized power supply; output: 15 V DC/4 A• Input rated value:

100 … 240 V AC; extended operating temperature range: up to +70 °C

6EP1 352-1SH03

LOGO!Power 24 VStabilized power supply; output: 24 V DC/1.3 A• Input rated value:

100 … 240 V AC; extended operating temperature range: up to +70 °C

6EP1 331-1SH03

Stabilized power supply; output: 24 V DC/2.5 A• Input rated value:

100 … 240 V AC; extended operating temperature range: up to +70 °C

6EP1 332-1SH43

Stabilized power supply; output: 24 V DC/4 A• Input rated value:

100 … 240 V AC; extended operating temperature range: up to +70 °C

6EP1 332-1SH52

LOGO! logic moduleLOGO! Power

Further information see Siemens Catalog ST 70 Further information about LOGO! Logic Module on the internet: www.siemens.com/logo

LOGO! Power

Page 22: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/10 Siemens Industry, Inc.Industrial Controls Catalog

Siemens / Industrial Controls Previous folio: 15/17

Overview

• The user-friendly software for creating control programs on a PC

• Creation of control programs in Function Block Diagram (FBD) or Ladder Diagram (LAD)

• Plus testing, simulation, online testing and archiving of control programs

• Professional documentation via numerous comment and print functions

Minimum system requirementsWindows 98 SE, NT 4.0, ME, 2000, XP (32 bit),Vista or 7 (32/64 bit)• PC Pentium.• 90 MB free disk capacity.• 64 MB RAM.• SVGA graphics card with minimum resolution 800x600

(256 colors).

Mac OS X• Mac OS X 10.4 with J2SE 1.5.0• Mac OS X 10.5 with J2SE 1.6.0• PowerMac G3, G4, G4 Cube, IMac, PowerBook G3, G4 or

iBook.

Linux• Tested with SUSE Linux 10 SP2, kernel 2.6.16• Runs on all Linux distributions on which the Java 2 SDK

Version 1.3.1 runs.• Please refer to your relevant Linux distribution for the

necessary hardware requirements.

Ordering data Order No.

LOGO!Soft Comfort V7.0 6ED1 058-0BA02-0YA1For programming on the PC inLAD/FBD; executes on Windows 7 (32/64 bit), VISTA, XP, NT4.0, 2000, 98SE, Linux and MAC OSX;on CD-ROM

LOGO!Soft Comfort V7.0 upgrade 6ED1 058-0CA02-0YE1Upgrade from V1.0 to V7.0

LOGO! logic moduleLOGO! Power

LOGO! software

Page 23: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/11Siemens Industry, Inc.Industrial Controls Catalog

SITOP Power SuppliesSwitched Mode Regulated Technology

Introduction

DC Power supplies for single phase applications 15 watts to 96 watts

DC Power Supplies for basic, single phase applications 36 watts to 300 watts

• Wide input voltage range on AC and DC networks for wide range of application uses, worldwide

• Output voltages of 5, 12, 15, or 24 VDC

• Wide operating temperature range from -20° to +70° C

• Worldwide agency approvals allow for universal applications

• Designed for basic applications that require switched-mode, regulated technology at a competitive price.

• SITOP Lite available in 24 VDC 2.5A, 5A, or 10 A

• SITOP Direct Mount available in 12 VDC and 24 VDC output voltages up to 300 Watts

• SITOP Direct Mount: direct wall mounting, allowing for variable mounting positions

DC Power supplies for standard and demanding single phase applications 60 watts to 960 watts

DC Power Supplies for three-phase applications 120 watts to 960 watts

• SITOP Smart available in 12 VDC or 24 VDC output voltages

• SITOP Modular 5A and 10A can be used on single phase and three phase networks

• Built-in relay contact for feedback to upper level control system for most units

• SITOP Smart 24 VDC/10A wall-mount version available for high shock and vibration requirements

• Comprehensive certifications for HazLoc and Marine applications

• Great for use with power security add-on modules

• Robust metal housing and metal DIN rail clip

• SITOP Smart available in 24 VDC 10A, 20A, or 40A

• SITOP Modular available in 24VDC and 48VDC output voltages

• Integrated signaling contact for “24 V OK”, high efficiencies, and slim, compact design

• Extra power of 150% for brief operational overloads for most units. SITOP Modular units feature power boost of 300% for 25ms for tripping protective devices.

• Great for use with power security add-on modules

Power Security Add-ons DC Uninterruptible Power Supplies

• The signaling module with signal contacts and remote ON/OFF function optimally integrates SITOP modular devices without integral signaling contact into automated plants.

• For maximum availability, the redundancy module decouples SITOP power supplies of the same type.

• The buffer module bridges short power failures up to 3 seconds with capacitors as energy storage.

• The SITOP select diagnosis and the newer, selectivity module offer selective protection of individual 24 V paths against over-load and short-circuits. With this protection and by means of fast fault localization, downtimes can be reduced to a minimum.

• DC UPS Modules (6A, 15A or 40A) in conjunction with battery modules (ranging from 1.2 Ah to 12 Ah) offer high security and availability of the power network

• DC UPS with capacitor back-up with with integrated energy storage 2.5 or 5 kWs, combinable with up to three expansion modules for absolutely maintenance free back-up thanks to high-capacity double layer capacitors

• The new DC UPS 1600 modules now offer reliable back-up in conjunction with DC UPS 1100 battery modules in 1.2, 3.2, or 7 Ah with even more possibilities for diagnostics and system integration thanks to an integrated web server and the option of an Ethernet/PROFINET interface

Page 24: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/12 Siemens Industry, Inc.Industrial Controls Catalog

SITOP Power SuppliesLow Wattage, Single Phase Switched-Mode TechnologyLOGO! Power: The flat power supply unit for distribution boards

Overview

These miniature power supply units offer great performance in a small space. They feature high efficiencies across the entire load range and lower power losses in no-load operation. The wide-range input allows operation on both AC and DC networks and the switch-on behavior has been optimized for capacitive loads. The operating temperature range has been extended to -20°C to +70°C allowing these power supplies with logic module design to be used in numerous applications - particularly suited for use in distribution boards thanks to their flat, stepped profile.

n 2 peformance classes each for 5 VDC, 12 VDC, and 15 VDC

n 3 performance classes for 24 VDC units

n Flat, stepped profile design

n Wide-range input for 85 - 264 VAC or 110 - 300 VDC

n Constant current for connection of loads with high inrush current

n Power reserve on starting up through 1.5x rated current

Selection and ordering data

Output Voltage (V DC)

Output Current (A)

Power (W)

Rated Input Voltage

Dimensions (WxHxD) mm

Ambient Temperature

Efficiency Short Circuit Protection

Certificates Approvals

Order No.

5 3 15 85..264 VAC110..300 VDC

54x90x55 -20°C…+70°C 77% Constant Current

CE, cULus, GL, ABS, ATEX, NEC Class2, Class I Div 2, FM

6EP1311-1SH03

12 1.9 23 85..264 VAC110..300 VDC

54x90x55 -20°C…+70°C 80% Constant Current

CE, cULus, FM,GL, ABS, ATEX,NEC Class 2,Class I Div 2

6EP1321-1SH03

15 1.9 29 85..264 VAC110..300 VDC

54x90x55 -20°C…+70°C 80% Constant Current

CE, cULus, cCSAus,ATEX, Class IDiv 2, GL , ABS

6EP1351-1SH03

24 1.3 31 85..264 VAC110..300 VDC

54x90x55 -20°C…+70°C 85% Constant Current

CE, cULus, FM,GL, ABS, ATEX,NEC Class 2,Class I Div 2

6EP1331-1SH03

5 6.3 32 85..264 VAC110..300 VDC

72x90x55 -20°C…+70°C 83% Constant Current

CE, cULus, GL, ABS, ATEX, Class I Div 2

6EP1311-1SH13

12 4.5 54 85..264 VAC110..300 VDC

72x90x55 -20°C…+70°C 85% Constant Current

CE, cULus, cCSAus,ATEX, Class IDiv 2, GL, NEC Class 2

6EP1322-1SH03

15 4 60 85..264 VAC110..300 VDC

72x90x55 -20°C…+70°C 85% Constant Current

CE, cULus, FM,GL, ABS, ATEX,cCSAus Class IDiv 2, NEC Class 2

6EP1352-1SH03

24 2.5 60 85..264 VAC110..300 VDC

72x90x55 -20°C…+70°C 88% Constant Current

CE, cULus, FM,GL, ABS, ATEX,cCSAus Class IDiv 2

6EP1332-1SH43

24 4 96 85..264 VAC110..300 VDC

90x90x55 -20°C…+70°C 89% Constant Current

CE, cULus, cCSAus,ATEX, Class IDiv 2, GL

6EP1332-1SH52

Page 25: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/13Siemens Industry, Inc.Industrial Controls Catalog

SITOP Power SuppliesLow Wattage, Single Phase Switched-Mode Technology

SITOP Compact: The slim power supply unit for control boxes

Overview

Thanks to the extremely space-saving slim design, this power supply series for lower performance ranges is especially suited to distributed applications in control boxes or in small control cabinets. These power supplies are characterized by their low power losses throughout the load range. The losses are extremely low even while idling, which makes them great for supply machines and plants which are frequently in stand-by mode. These power supply units have a wide range input for AC and DC networks and plug-in terminals that facilitate the electrical connection.

n Small mounting surface thanks to its slim design

n Wide-range input for 85 - 264 VAC or 110 - 300 VDC

n Low energy consumption during no-load operation or stand-by

n High efficiency across the entire load range

n Up to 28% energy savings in comparison to similar devices

n Plug-in terminals for easy electrical connection

Selection and ordering data

Output Voltage (V DC)

Output Current (A)

Power (W)

Rated Input Voltage

Dimensions (WxHxD) mm

Ambient Temperature

Efficiency Short Circuit Protection

Certificates Approvals

Order No.

24 0.6 14 85..264 VAC110..300 VDC

22.5x80x100 -20°C…+70°C 82% Auto Restart

CE, cULus, cCSAus, ATEX, Class I Div 2 GL, ABS, NEC Class 2

6EP1331-5BA00

12 2 24 85..264 VAC110..300 VDC

30x80x100 -20°C…+70°C 82% Auto Restart

CE, cULus, cCSAus,ATEX, Class IDiv 2, GL ABS

6EP1321-5BA00

24 1.3 31 85..264 VAC110..300 VDC

30x80x100 -20°C…+70°C 86% Auto Restart

CE, cULus, cCSAus,ATEX, Class IDiv 2, GL, ABS, NEC Class 2

6EP1331-5BA10

24 2.5 60 85..264 VAC110..300 VDC

45x80x100 -20°C…+70°C 89% Auto Restart

CE, cULus, cCSAus,ATEX, Class IDiv 2, GL, ABS, NEC Class 2

6EP1332-5BA00

12 6.5 78 85..264 VAC110..300 VDC

52.5x80x100 -20°C…+70°C 85% Auto Restart

CE, cULus, cCSAus,ATEX, Class IDiv 2, GL, ABS

6EP1322-5BA10

24 3.7 89 85..264 VAC110..300 VDC

52.5x80x100 -20°C…+70°C 87% Auto Restart

CE, cULus, cCSAus,ATEX, NEC Class 2, GL, ABS, Class I

6EP1332-5BA20

24 4 96 85..264 VAC110..300 VDC

52.5x80x100 -20°C…+70°C 88% Auto Restart

CE, cULus, cCSAus,ATEX, Class IDiv 2, GL, ABS

6EP1332-5BA10

Page 26: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/14 Siemens Industry, Inc.Industrial Controls Catalog

SITOP Power SuppliesBasic, Single Phase Switched-Mode Technology

SITOP Lite: Low-cost basic power supply

Overview

This new range of power supplies is designed for standard requirements in industrial environments and offers all important functions at a favorable price, of course without compromising quality and the proverbial SITOP reliability. The wide range input with manual switchover supports connection to a wide range of 1-phase supply systems.

Thanks to the narrow width, the primary switched-mode units require little space on the DIN rail, and the good efficiency results in low thermal losses in the control cabinet. Short-circuit and overload protection as well as UL approval for export ensure problem- free use.

n 24 VDC/ 2.5A, 5A,10A for industrial applications with standard requirements

n 1-phase wide-range input with manual switch-over

n Narrow mounting width

n High degree of efficiency

n Parallel connection possible

n Ambient temperature range of 0…+60°C (above +45°C with derating)

Selection and ordering data

Output Voltage (V DC)

Output Current (A)

Power (W)

Rated Input Voltage

Dimensions (WxHxD) mm

Ambient Temperature

Efficiency Short Circuit Protection

Certificates Approvals

Order No.

24 2.5 60 85..132/ VAC170…264 VAC(manual switch)

32.5x125x125 0°C…+60°C 85% Constant Current

CE, cULus 6EP1332-1LB00

24 5 120 85..132/ VAC170…264 VAC(manual switch)

50x125x125 0°C…+60°C 86% Constant Current

CE, cULus 6EP1333-1LB00

24 10 240 85..132/ VAC170…264 VAC(manual switch)

70x125x125 0°C…+60°C 90% Constant Current

CE, cULus 6EP1334-1LB00

Page 27: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/15Siemens Industry, Inc.Industrial Controls Catalog

SITOP Power SuppliesBasic, Single Phase Switched-Mode Technology

SITOP Direct Mount: Cost-effective power supply for wall mounting

Overview

This attractively priced regulated power supplies can be screwed directly onto the wall. The rugged aluminum enclosure with IP20 degree of protection can be variably mounted in different positions, even in applications with high temperatures and high shock and vibration requirements.

The wide-range input enables connectivity to the most diverse supply networks worldwide and ensures reliable 12 V DC or 24 V DC supply even if there are large voltage fluctuations. Short circuit and overload protection as well as international certifica-tions ensure problem free and universal use.

n Wall mounting for variable mounting positions

n Aluminum, IP 20 enclosure

n High shock and vibration resistance for harsh environments

n 1 phase wide-range input 85..264 VAC

n UL 508 rated

Selection and ordering data

Output Voltage (V DC)

Output Current (A)

Power (W)

Rated Input Voltage

Dimensions (WxHxD) mm

Ambient Temperature

Efficiency Short Circuit Protection

Certificates Approvals

Order No.

12 3 36 85..264 VAC 97x98x38 -10°C…+70°C 84% Auto Restart

CE, cULus, cURus

6EP1321-1LD00

24 2.1 50 85..264 VAC 97x128x38 -10°C…+70°C 86% Auto Restart

CE, cULus, cURus

6EP1331-1LD00

24 3.1 74 85..264 VAC 97x128x38 -10°C…+70°C 86% Auto Restart

CE, cULus, cURus

6EP1332-1LD00

12 8.3 100 85..264 VAC 97x158x38 -10°C…+70°C 84% Auto Restart

CE, cULus, cURus

6EP1322-1LD00

24 4.1 98 85..264 VAC 97x158x38 -10°C…+70°C 86% Auto Restart

CE, cULus, cURus

6EP1332-1LD10

24 6.2 149 85..264 VAC 97x178x38 -10°C…+70°C 86% Auto Restart

CE, cULus, cURus

6EP1333-1LD00

24 12.5 300 85..264 VAC 105x199x38 -10°C…+70°C 86% Auto Restart

CE, cULus, cURus

6EP1334-1LD00

Page 28: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/16 Siemens Industry, Inc.Industrial Controls Catalog

SITOP Power SuppliesStandard, Single Phase Switched-Mode TechnologySITOP Smart: The powerful standard power supply

Selection and ordering data

Output Voltage (V DC)

Output Current (A)

Power (W)

Rated Input Voltage

Dimensions (WxHxD) mm

Ambient Temperature

Efficiency Short Circuit Protection

Certificates Approvals

Order No.

24 2.53 (to 45°C)

60 85..132/ VAC170…264 VAC (automatic switch

32.5x125x125 -10°C…+70°C 85% Constant Current

CE, cULus, ATEX, GL, Class I Div 2

6EP1332-2BA20

24 56 (to 45°C)

120 85..132/ VAC170…264 VAC (automatic switch

50x125x125 -10°C…+70°C 88% Constant Current

CE, cULus, ATEX, GL, Class I Div 2

6EP1333-2BA20

12 7 84 85..132/ VAC170…264 VAC (automatic switch

50x125x125 -10°C…+70°C 84% Constant Current

CE, cULus, ATEX, GL, Class I Div 2

6EP1322-2BA00

24 1012 (to 45°C)

240 85..132/ VAC170…264 VAC (automatic switch

70x125x125 -10°C…+70°C 87% Constant Current

CE, cULus, ATEX, GL, Class I Div 2

6EP1334-2BA20

12 14 168 85..132/ VAC170…264 VAC (automatic switch

70x125x125 -10°C…+70°C 87% Constant Current

CE, cULus, ATEX, GL, Class I Div 2

6EP1323-2BA00

24 1012 (to 45°C)

240 85..132/ VAC170…264 VAC (automatic switch

70x125x125 0°C…+60°C 90% Constant Current

CE, UL, CSA, ATEX, GL, Class I Div 2

6EP1334-2AA01-0AB0

24 2024 (to 45°C)

480 85..132/ VAC170…264 VAC (automatic switch

115x145x150 0°C…+70°C 90% Auto Restart

CE, UL, CSA, ATEX, GL, Class I Div 2

6EP1336-2BA10

Overview

SITOP smart is the optimum power supply for standard applications in 12 VDC or 24 VDC. They offer compact dimensions, a strong performance, and a favorable price. Despite its compactness it offers an outstanding overload with-stand capability. Thanks to the extra power feature with 1.5 times the rated current for 5 seconds, even large loads can be switched on without any problems. With a continuous rated power of 120 percent, the slim power supply units are among the most reliable of their kind. Numerous certifications facilitate the universal and global use and permit their use in hazardous areas.

n Output voltages in 12 VDC or 24 VDC

n All 24 VDC units feature 120% continuous overload at 45°C or less

n All units with extra power of 1.5x rated current for 5s/min

n All 12 VDC and 24 VDC units (except the Wallmount variation) feature automatic input range detection and an integrated relay contact

n SITOP Smart Wallmount 24V/10 A version for applica-tions that require high shock and vibration

Page 29: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/17Siemens Industry, Inc.Industrial Controls Catalog

SITOP Power SuppliesStandard, Single Phase Switched-Mode Technology

SITOP Modular: The technology power supply for demanding solutions

Selection and ordering data

Output Voltage (V DC)

Output Current (A)

Power (W)

Rated Input Voltage

Dimensions (WxHxD) mm

Ambient Temperature

Efficiency Short Circuit Protection

Certificates Approvals

Order No.

24 5 120 85..264 VAC/176..550 VAC (manual switch)

70x125x125 -25°C…+70°C 87% Constant Current or Latching Shutdown

CE, cULus, GL, ABS, ATEX, Class I Div 2, SEMI F471)

6EP1333-3BA00

24 10 240 85..264 VAC/176..550 VAC (manual switch)

90x125x125 -25°C…+70°C 87% Constant Current or Latching Shutdown

CE, cULus, GL, ABS, ATEX, Class I Div 2, SEMI F471)

6EP1334-3BA00

24 20 480 85..275 VAC88..350 VDC

90x125x125 -25°C…+70°C 93% Constant Current or Latching Shutdown

CE, cULus, GL, ABS, ATEX, Class I Div 2

6EP1336-3BA10

24 20 480 85..132/ VAC176…264 VAC (manual switch)

160x125x125 0°C…+70°C 89% Constant Current or Latching Shutdown

CE, cULus, GL, ABS, ATEX

6EP1336-3BA00

24 40 960 85..132/ VAC176…264 VAC (manual switch)

240x125x125 0°C…+70°C 88% Constant Current or Latching Shutdown

CE, cULus, ATEX

6EP1337-3BA00

1) At input voltage 208 to 230 VAC

Overview

SITOP modular fulfills the highest functionality requirements, e.g. for use in complex plants and machines. The wide-range input allows a connection to almost any electrical power system worldwide and ensures a high degree of safety even if there are large voltage fluctuations. The power boost provides up to three times the rated current for brief periods. In the event of an overload, you have two options: Constant current with automatic restart or latching shutdown. The newly innovated PSU100M features a DC input voltages and an integrated signaling contact.

n SITOP Modular 5A and 10A feature extra wide input voltage range for uses on either 1-phase or 3-phase networks in one unit

n SITOP Modular PSU100M 24V/20A features integrated relay contact, DC input voltage range, and high efficiency of 93%

n All units feature power boost of 3x rated current for 25ms

n Load sharing functionality makes this the ideal product for use with power security add-ons (e.g. Redundancy Modules)

Page 30: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/18 Siemens Industry, Inc.Industrial Controls Catalog

SITOP Power SuppliesStandard, Three Phase Switched-Mode TechnologySITOP Smart: The powerful standard power supply

Overview

SITOP smart is the optimum power supply for many applica-tions in 24 VDC. They offer compact dimensions, a strong performance, and a favorable price. Despite its compactness it offers an outstanding overload withstand capability.

Thanks to the extra power feature with 1.5 times the rated current for 5 seconds, even large loads can be switched on without any problems. With a continuous rated power of 120 percent, the slim power supply units are among the most reli-able of their kind. Numerous certifications facilitate the univer-sal and global use and permit their use in hazardous areas.

n Output voltages in 24 VDC

n All units feature 120% continuous overload at 45°C or less.

n All units feature extra power of 1.5x rated current for 5s/min

n All units with built-in signaling contact for “24 V DC ok”

n Robust metal housing and metal DIN rail clip

n Expandable with power security add-on components

Selection and ordering data

Output Voltage (V DC)

Output Current (A)

Power (W)

Rated Input Voltage

Dimensions (WxHxD) mm

Ambient Temperature

Efficiency Short Circuit Protection

Certificates Approvals

Order No.

Smart Family24 10 240 340…550 V 3 AC 90x145x150 0°C…+70°C 91% Auto

RestartCE, cULus, ATEX, Class I Div 2, GL

6EP1434-2BA10

24 20 480 340…550 V 3 AC 90x145x150 0°C…+70°C 91% Auto Restart

CE, cULus, ATEX, Class I Div 2, GL

6EP1436-2BA10

24 40 960 340…550 V 3 AC 150x145x150 0°C…+70°C 91.5% Auto Restart

CE, cULus, ATEX, Class I Div 2, GL

6EP1437-2BA20

Page 31: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/19Siemens Industry, Inc.Industrial Controls Catalog

SITOP Power SuppliesStandard, Three Phase Switched-Mode Technology

SITOP Modular: The technology power supply for demanding solutions

Overview

SITOP modular fulfills the highest functionality requirements,e.g. for use in complex plants and machines. The wide-range input allows a connection to almost any electrical power system worldwide and ensures a high degree of safety even if there are large voltage fluctuations.

The power boost provides up to three times the rated current for brief periods. In the event of an overload, you have two options: Constant current with automatic restart or latching shutdown. The newly innovated PSU300M features a DC input voltages and an integrated signaling contact.

n SITOP Modular 5A and 10A feature extra wide input voltage range for uses on either 1-phase or 3-phase networks in one unit

n Output voltages in 24 VDC and 48 VDC

n SITOP Modular PSU300M 24V/20A, 24V/40A, 48V/10A features integrated relay contact, extra power of 1.5x rated current, and high efficiency of 93%

n All units feature power boost of 3x rated current for 25ms

n Robust metal housing and metal DIN Rail clip

n Load sharing functionality makes this the ideal product for use with power security add-ons (e.g. Redundancy Modules)

Selection and ordering data

Output Voltage (V DC)

Output Current (A)

Power (W)

Rated Input Voltage

Dimensions (WxHxD) mm

Ambient Temperature

Efficiency Short Circuit Protection

Certificates Approvals

Order No.

Modular Family24 5 120 85..264 VAC/

176..550 VAC(manual switch)

70x125x125 -25°C…+70°C 87% Contant Current or latching shutdown

CE, cULus, GL, ABS, ATEX, Class I Div 2, SEMI F471)

6EP1333-3BA00

24 10 240 85..264 VAC/176..550 VAC(manual switch)

90x125x125 -25°C…+70°C 87% Contant Current or latching shutdown

CE, cULus, GL, ABS, ATEX, Class I Div 2, SEMI F471)

6EP1334-3BA00

24 20 480 320…575 V 3 AC 70x125x125 -25°C…+70°C 93% Contant Current or latching shutdown

CE, cULus, GL, ABS, SEMI F47, ATEX, Class I Div 2

6EP1436-3BA10

48 10 480 320…575 V 3 AC 70x125x125 -10°C…+70°C 93% Constant Current or Latching Shutdown

CE, cULus, GL, ABS, ATEX, Class I Div 2

6EP1456-3BA00

24 20 480 340...550 V 3 AC 160x125x125 0°C…+70°C 90% Auto Restart

CE, UL, CSA, GL, ABS, SEMI F47

6EP1436-3BA00

24 40 960 320...550 V 3 AC 150x125x150 -25°C…+70°C 93% Auto Restart

CE, UL, CSA, GL, ABS, SEMI F47, ATEX, Class I Div 2

6EP1437-3BA10

24 40 960 340…550 V 3 AC 240x125x125 0°C…+70°C 90% Auto Restart

CE, UL, CSA, SEMI F47

6EP1437-3BA00

48 20 960 340…550 V 3 AC 240x125x125 0°C…+60°C 90% Auto Restart

CE, UL, CSA, GL, ABS

6EP1457-3BA00

1) At input voltage 208 to 230 VAC

Page 32: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/20 Siemens Industry, Inc.Industrial Controls Catalog

Selection and ordering data

Output Voltage (V DC)

Output Current (A)

Power (W)

Rated Input Voltage

Dimensions (WxHxD) mm

Ambient Temperature

Efficiency Short Circuit Protection

Certificates Approvals

Order No.

PSU300E Family24 5 120 320…575 V 3 AC 42x125x125 0°C…+60°C 90% Auto

RestartCE, cULus, ATEX, cCSAus Class I Div 2, GL

6EP1424-3BA0

PSU300B Family12 20 240 320…575 V 3 AC 70x125x125 -25°C…+60°C 86% Contant

Current or latching shutdown

CE, cULus 6EP1433-0AA00

24 17 408 320…575 V 3 AC 70x125x125 -25°C…+70°C 93% Contant Current or latching shutdown

CE (cULus pending)

6EP1436-3BA20

24 30 720 320…575 V 3 AC 150x125x125 -25°C…+70°C 93% Contant Current or latching shutdown

CE, cULus 6EP1427-3BA00

SITOP Power SuppliesThree Phase Power Supplies in Special DesignSITOP in Special Design: Well prepared for special tasks and conditions

OverviewSITOP PSU300E: three-phase power supply with low output and removable plug-in terminals.

n Sturdy metal enclosure is only 42 mm wide and does not require mounting distances on the sides to other devices

n Low heat generation due to the high efficiency level of 90%

n The wide input range of 320 V to 550 V 3AC allows for mains buffering times of 50 ms, thus enabling use in unstable three-phase systems

n Removable plug-in terminals simplify the connection to AC and DC

n An LED and an integrated “DC 24 V OK” signaling contact indicate the status of the output voltage

n Output voltage can be adjusted from 24 V to 29 V

SITOP PSU300B: three-phase power supply optimized for battery charging

n Available in output in 12 VDC and 24 VDC output voltages

n High efficiencies up to 93%

n Slim, compact design without the need for lateral mounting clearance

n Constant current characteristic makes them optimal for battery charging

n Wide range input for voltages 3AC 320 to 575 V allow for use in traditional three-phase applications

Page 33: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/21Siemens Industry, Inc.Industrial Controls Catalog

SITOP Power SuppliesSingle Phase Power Supplies in Special Design

SITOP in Special Design: Well prepared for special tasks and conditions

Overview SIMATIC Design:

n The original SIMATIC power supplies merge perfectly into the PLC network in terms of their design and functionality.

n SIMATIC S7-200: this flat power supply unit is also used for low installation depths

n SIMATIC S7-1200: the compact PM1207 power module supplies power to the S7-1200 micro PLC.

n SIMATIC S7-300: these innovative power supplies feature automatic switchover on 120/230 VAC networks and a slimmer design than older versions of the PS307

n SIMATIC S7-1500: the compact PM1507 power modules supply power to the newly released, SIMATIC S7-1500 PLC

Other Types: n DC/DC Converter: features a narrow DIN rail housing and

needs a 24 V DC input voltage - it can also be used in conjuc-tion with a DC UPS to provided an uninterruptible 12 VDC.

n Dual: the electronics power supply for the control cabinet; the industry-standard rail mounted device has two 15 VDC outputs for loads that may require ±15 V DC

n Flexi: limitless diversity thanks to variable output. Allows flexible adjustment between 3 and 52 VDC so just one standard power supply can be used for different voltages

n PSU400M: compact DC/DC converter with wide DC input voltage range from 200 to 900 VDC. Ideally suited for use with frequency-controlled drive systems

SITOP Power Supplies

Selection and ordering data

Output Voltage (V DC)

Output Current (A)

Power (W)

Rated Input Voltage

Dimensions (WxHxD) mm

Ambient Temperature

Efficiency Certificates Approvals

Order No.

SIMATIC DesignSIMATIC S7-200 24 3.5 84 85..132 V AC/

176..264 VAC(auto switch)

160x80x62 0°C…+60°C 84% CE, cULus 6EP1332-1SH31

SIMATIC S7-1200 24 2.5 60 85..132 V AC/176..264 VAC(auto switch)

70x100x75 0°C…+60°C 83% CE, cULus, ATEX, cCSAusClass I Div 2, GL, ABS

6EP1332-1SH71

SIMATIC S7-300 24 2 48 85..132 V AC/170..264 VAC(auto switch)

40x125x120 0°C…+60°C 84% CE, cULus, ATEX, cULus Class I Div 2, GL, ABS

6ES7307-1BA01-0AA0

24 5 120 85..132 V AC/170..264 VAC(auto switch)

60x125x120 0°C…+60°C 86% CE, cULus, ATEX, cULus Class I Div 2, GL, ABS

6ES7307-1EA01-0AA0

24 10 240 85..132 V AC/170..264 VAC(auto switch)

80x125x120 0°C…+60°C 90% CE, cULus, ATEX, cULus Class I Div 2, GL, ABS

6ES7307-1KA02-0AA0

SIMATIC S7-1500 24 3 72 85..132 V AC/176..264 VAC(auto switch)

50x141x135 0°C…+60°C 87% CE, cULus, FM, ATEX, pending: cULus Class IDiv 2, GL, ABS

6EP1332-4BA00

SIMATIC S7-1500 24 8 192 85..132 V AC/176..264 VAC(auto switch)

75x147x135 0°C…+60°C 91% CE, cULus, FM, ATEX, pending: cULus Class IDiv 2, GL, ABS

6EP1333-4BA00

Other TypesDC/DC 12 2.5 30 24 VDC

(18.5..30.2 V DC)32.5x125x125 0°C…+60°C 80% CE, cULus 6EP1621-2BA00

Dual 2x15 3.5 105 93..264 V AC 75x125x125 0°C…+60°C 80% CE 6EP1353-0AA00

Flexi 3.52 10 max 120W

85..132 V AC/170…264 V AC

75x125x125 0°C…+60°C 84% CE, cULus 6EP1353-2BA00

PSU400M 24 20 480 200…900 V DC(start-up from 400 V DC)

90x125x125 -25°C…+70°C

95% CE, cULus, GL (ABS pending)

6EP1536-3AA00

Page 34: Control Circuit Components AS-Interface, IO Link · 2019-07-18 · sensors that are activated as AS-Interface slaves. Benefits A key feature of AS-Interface technology is the use

15/22 Siemens Industry, Inc.Industrial Controls Catalog

Overview

A power supply unit on its own cannot guarantee a fault-free 24 V DC supply. Power failures, extreme variations in the mains voltage, or a faulty load can bring plant operation to a standstill and cause high costs. The expansion modules offer everything from extensive protection against interference on the primary and secondary side right up to complete all-round protection.

n Signaling Module: Module for snapping onto the side of the basic unit SITOP modular (6EP1x3x-3BA00, 6EP1457-3BA00); automatic contacting, with floating signaling contacts for “Output voltage o.k.” and “Operating readiness o.k.”; with signal input for switching the basic unit ON/OFF remotely.

n Buffer Module: Module for mains buffering; parallel con-nection at output of 24 V basic units (6EP1x3x-3BAxx); buffering time 200 ms at 40 A to 1.6 s at 5 A load current; multiplication possible through parallel connection; maxi-mum buffer time 10 s.

n Redundancy Module: Module for redundancy mode. Floating relay contact and green LED for signaling “Infeed 1 and 2 o.k.”, switching threshold adjustable between 20 to 25 V DC.

n Selectivity/Select Diagnosis Module: Module for distrib-uting the 24 V DC supply over up to four load circuits and their monitoring for overload; selective shutdown of faulty

SITOP Power SuppliesPower Security Add-On Modules

SITOP Expansion Modules

Selection and ordering data

Output Voltage (V DC)

Output Current (A)

Power (W)

Rated Input Voltage

Dimensions (WxHxD) mm

Ambient Temperature

Efficiency Certificates Approvals

Notes Order No.

SITOP Expansion ModulesSignaling N/A N/A 84 Contact

Rating:240 V AC/ 6 A

25x125x125 0…+60°C N/A CE, UL, CSA

6EP1961-3BA10

Buffer 24 40 60 24 V DC (24..28.8 VDC)

70x125x125 0…+60°C N/A CE, UL, CSA, GL, ABS, ATEX, Class I Div 2

6EP1961-3BA01

Redundancy 24 10* 48 24 V DC (19..29 VDC)

30x80x100 -20°…+60°C 97% CE, cULus Decouple of 2 5 A or one 10A power supply per redundancy module

6EP1964-2BA00

24 3.5* 120 24 V DC (19..29 VDC)

30x80x100 -20°…+60°C 95% CE, cULus, NEC Class 2

Decoupling and limitation of the output to Class 2 limit (100 W) of 2 power supplies 5 to 40.

6EP1962-2BA00

Redundancy 24 40* 240 24 V DC (24..28.8 VDC)

70x125x125 0…+60°C 97% CE, cULus, cCSAus Class I Div 2,ATEX, GL, ABS

Decouple of 2 5 to 20 A or one 40A power supply per redun-dancy module

6EP1961-3BA21

Selectivity 24 4 x 3A (0.5A…3A)

72 24 V DC (22...30 VDC)

72x80x72 0…+60°C 97% CE, UL, cURus, cCSAus Class I Div 2, ATEX, GL (ABS pending)

Individual load circuits can be switched on sequentially. Status indication via 3-color LED per channel; remote reset with 24 V signal and reset via pushbuttonper channel; common signal-ing contact

6EP1961-2BA116EP1961-2BA31**

24 4 x 10 A(3A...10 A)

192 24 V DC (22...30 VDC)

72x80x72 0…+60°C 97% CE, UL, cURus, cCSAus Class I Div 2, ATEX, GL (ABS pending)

6EP1961-2BA216EP1961-2BA41**

Select Diagnosis 12 4 x 10 A(2A...10 A)

30 24 V DC (22...30 VDC)

72x90x90 0…+60°C 97% CE, UL, cURus, cCSAus Class I Div 2, ATEX

Status indication via 2-color LED per channel; common reset via pushbutton, plug-in fuseper channel; status indication via 3-color LED per channel; common signal-ing contact.

6EP1961-2BA00

*Total Current**With single channel signaling for individual channel specific analyses