CSB LOA 24 Control unit BO Control unit BO BRAHMA ................................. CSB.240 CEM ECEE ................................ CSB.241 DANFOSS.................................. CSB.243 DUNGS ..................................... CSB.244 ELESTA ...................................... CSB.244 HONEYWELL .............................. CSB.244 LANDIS & GYR - STAEFA - SIEMENS ...............................................CSB.247 PACTROL ................................... CSB.252 RIELLO ...................................... CSB.253 RV ............................................ CSB.254 SATRONIC.................................. CSB.254 SIT ............................................. CSB.258 Insulation transformer .............. CSB.259 Micro ammeter ......................... CSB.259 Connector ................................. CSB.259 Ignition spark detector ..............CSB.262 Control and Flame security Sit control unit Cell Microammeter Double connector

Control Box - Boiler Parts - Boilerparts.co.ke

Embed Size (px)

DESCRIPTION

Control Box parts from the following manufacturer(s):BRAHMA - CSB.240CEM ECEE - CSB.241DANFOSS - CSB.243DUNGS - CSB.244ELESTA - CSB.244HONEYWELL - CSB.244LANDIS & GYR - STAEFA - SIEMENS - CSB.247PACTROL - CSB.252RIELLO - CSB.253RV - CSB.254SATRONIC - CSB.254SIT - CSB.258Insulation transformer - CSB.259Micro ammeter - CSB.259Connector - CSB.259Ignition spark detector - CSB.262

Citation preview

CSB

LOA 24

Controlunit

BO

Cont

rol u

nit

BO

BRAHMA ................................. CSB.240

CEM ECEE ................................CSB.241

DANFOSS .................................. CSB.243

DUNGS ..................................... CSB.244

ELESTA ......................................CSB.244

HONEYWELL ..............................CSB.244

LANDIS & GYR - STAEFA -SIEMENS ...............................................CSB.247

PACTROL ................................... CSB.252

RIELLO ...................................... CSB.253

RV ............................................ CSB.254

SATRONIC ..................................CSB.254

SIT .............................................CSB.258

Insulation transformer .............. CSB.259

Micro ammeter ......................... CSB.259

Connector .................................CSB.259

Ignition spark detector ..............CSB.262

Control and Flame security

Sit control unit

Cell

Microammeter

Double connector

Control unit

CSB.238

BO

Cont

rol u

nit

Classifi cation by brand and manufacturer references

CEM

ECE

E

MA 26 501300 CSB.241

MA 28 501310 CSB.241

MA 29 501320 CSB.241

MA 310-12 501100 CSB.241

MA 41 501370 CSB.242

MA 410-1 501010 CSB.241

MA 43 501350 CSB.242

MA 45 501380 CSB.242

MA 46 501385 CSB.242

MA 510-1 501010 CSB.241

MA 510-1 501009 CSB.241

MA 52 501375 CSB.241

MA 53 501374 CSB.241

MA 55 501376 CSB.242

MA 55D 501373 CSB.242

MA 55E 501379 CSB.242

MA 55H 501377 CSB.242

MA 55R 501378 CSB.242

MA 610-1 501020 CSB.241

MA 710 501020 CSB.241

MA 72 501330 CSB.241

MA 73 501340 CSB.241

MA 800 501040 CSB.241

MA 803 501050 CSB.241

MA 810 501060 CSB.241

MA 86-02 501391 CSB.241

MA 86-04 501391 CSB.241

MA 86-05B 501391 CSB.241

MA 86-11 501392 CSB.241

MA 87-02 501391 CSB.241

MA 910 501020 CSB.241

DANF

OSS

BHO 62-7034/7234 see 505156 CSB.243

BHO 62D-7035/7235 see 505156 CSB.243

BHO 64.1-7037 see 505157 CSB.243

BHO 64-7036/7236 see 505156 CSB.243

BHO 72.10 57H6102 505156 CSB.243

BHO 72.11 57H6103 505157 CSB.243

BHO 73.10 57H6104 505158 CSB.243

BHO 74.10 57H6105 505159 CSB.243

FFW 507320 CSB.244

DUNG

S

DGAI 19.2 509000 CSB.244

DGAI 69 509005 CSB.244

VDK200A 509001 CSB.244

VPS504 509003 CSB.244

VPS504 509004 CSB.244

W-FM20 V3.02 502 407103 CSB.244

HON

EYW

ELL

S4560 A 1024 508019 CSB.249

S4560 A 1032 508035 CSB.249

S4560 B 1006 508057 CSB.249

S4560 B 1022 508028 CSB.249

S4560 B 1048 508009 CSB.249

S4560 B 1063 508036 CSB.249

S4560 C 1004 508062 CSB.249

S4560 C 1038 508024 CSB.249

S4560 C 1053 508038 CSB.249

S4560 CB 1022 508012 CSB.249

S4560 D 1077 508020 CSB.249

S4560 D 1135 508039 CSB.249

S4560 D 1143 508034 CSB.249

S4560 D 1150 508059 CSB.249

S4560 M 1036 508025 CSB.249

S4561 A 1007 508056 CSB.249

S4561 A 1015 508040 CSB.249

BRAH

MA

AT5 504031 CSB.240

AT5/TR1 504030 CSB.240

CM11 504036 CSB.240

CM11F 504050 CSB.240

CM191.1 504003 CSB.240

CM191.2/T1.5 504049 CSB.240

CM31 504039 CSB.240

CM31 504040 CSB.240

CM31 40030 CSB.240

CM31 504055 CSB.240

CM31F 504005 CSB.240

CM32 504002 CSB.240

CM32 504037 CSB.240

CM32 504038 CSB.240

CM32 504051 CSB.240

CM32 504052 CSB.240

CM32 PR 504056 CSB.240

CM391.2 504035 CSB.240

CM391.2 504057 CSB.240

CM391.2 504060 CSB.240

CM391.2 40029 CSB.240

DM 32 504054 CSB.240

EM41 37201031 402010 CSB.240

ER1 see 402023 CSB.240

ER1H see 402023 CSB.240

FR1 504044 CSB.240

G22/03 seule 504019 CSB.240

G22/09 seule 504023 CSB.240

G33/03 504006 CSB.240

GF2/03 seule 504018 CSB.240

GF3/03 seule 504004 CSB.240

M300/02 504027 CSB.240

MF2/02 504033 CSB.240

OF1PR 504058 CSB.240

OR3/B 431131 CSB.240

SM11 504024 CSB.240

SM152.2 504001 CSB.240

SM152.2 504059 CSB.240

SM191.2 504048 CSB.240

SM192.2 504053 CSB.240

SR3/02 504028 CSB.240

SR3/TR see 504029 CSB.240

SR3/TR01 504029 CSB.240

SR3/TR15 504026 CSB.240

SR3V 504047 CSB.240

TEC3 431260 CSB.240

TM11-37059010 504042 CSB.240

TM31-37065010 504043 CSB.240

VE3-2/05 504025 CSB.240

XM11F 40054 CSB.240

CEM

ECE

E

AE25 501900 CSB.242

GA 2410 501615 CSB.242

GA 2510 501620 CSB.242

GB 650 501656 CSB.242

GB 650.1 501622 CSB.242

GE 143 501600 CSB.242

GE 145 501605 CSB.242

GE 236-01 501650 CSB.242

GE 296 501601 CSB.242

GE 633 501630 CSB.242

GE 650 501656 CSB.242

GE 733 501631 CSB.242

GE 735 501632 CSB.242

GU 336-01 501655 CSB.243

MA 152.01 sur devis CSB.241

MA 23 501360 CSB.241

MA 25 501300 CSB.241

HON

EYW

ELL

S4561 B 1005 508041 CSB.249

S4561 B 1013 508042 CSB.249

S4561 B 1039 508007 CSB.249

S4562 A 1055 508005 CSB.249

S4562 C 1069 508006 CSB.249

S4562 DM 1006 40503 CSB.249

S4565 A 2019 508026 CSB.244

S4565 A 2027 508003 CSB.244

S4565 A 2035 508050 CSB.244

S4565 A 2050 508021 CSB.244

S4565 A 2068 508053 CSB.244

S4565 A 2076 508082 CSB.244

S4565 AD 2056 508016 CSB.244

S4565 AD 2072 508004 CSB.244

S4565 AD 2080 508079 CSB.244

S4565 AF 1007 508054 CSB.244

S4565 AF 1064 508060 CSB.244

S4565 B 2066 404049 CSB.244

S4565 BD 2021 508073 CSB.244

S4565 BF 1005 508052 CSB.244

S4565 BF 1047 508051 CSB.244

S4565 BF 1054 508074 CSB.244

S4565 BF 1062 508029 CSB.244

S4565 BF 1112 508043 CSB.245

S4565 BF 1161 508071 CSB.245

S4565 BM 1080 508072 CSB.244

S4565 C 1025 508058 CSB.244

S4565 C 1132 508075 CSB.244

S4565 CD 1021 508076 CSB.245

S4565 CD 2029 508002 CSB.244

S4565 CF 1045 508001 CSB.245

S4565 CF 1052 508063 CSB.244

S4565 CF 1060 508046 CSB.245

S4565 D 1007 508047 CSB.244

S4565 DD 1003 508081 CSB.245

S4565 DD 1045 431171 CSB.245

S4565 DF 1050 508078 CSB.245

S4565 DM 1029 508064 CSB.245

S4565 DM 1045 508048 CSB.244

S4565 P 2024 508008 CSB.244

S4565 QM 1012 508065 CSB.245

S4565 RF 1000 508077 CSB.244

S4565 SD 2005 508069 CSB.244

S4565CD2037 508083 CSB.245

S4565D1023 508084 CSB.245

S4570 AS 1012 508030 CSB.245

S4570 BS 1002 508011 CSB.245

S4570 BS 1010 508027 CSB.245

S4570 BS 1028 508067 CSB.245

S4570 BS 1036 508031 CSB.245

S4570 LS 1000 508033 CSB.245

S4570 LS 1026 508066 CSB.245

S4570 LS 1059 454064 CSB.245

S4570 LS 1091 508086 CSB.245

LAND

IS &

GYR

- ST

AEFA

- SI

EMEN

S

LAE 1/1355 502172 CSB.247

LAL 1.25 502091 CSB.247

LAL 2.14 502092 CSB.247

LAL 2.25 502094 CSB.247

LAL 2.65 502093 CSB.247

LDU 11 523A27 502111 CSB.252

LEC 1/8 853 502173 CSB.249

LFE 10 502170 CSB.249

LFE 50 502001 CSB.249

LFL 1.122 502107 CSB.250

LFL 1.133 502004 CSB.250

LFL 1.148 502112 CSB.250

LFL 1.322 502101 CSB.250

LFL 1.322F 502104 CSB.250

LFL 1.333 502109 CSB.250

Manufact. Ref. Ref Page Manufact. Ref. Ref Page Manufact. Ref. Ref Page

Control unit

CSB.239

Cont

rol u

nit

BO

LAND

IS &

GYR

- ST

AEFA

- SI

EMEN

S

LFL 1.335 502102 CSB.250

LFL 1.622 502110 CSB.250

LFL 1.622F 502103 CSB.250

LFL 1.635 502106 CSB.250

LGB 21 130A27 502205 CSB.250

LGB 21 330A27 502177 CSB.250

LGB 21 350A27 502206 CSB.250

LGB 21 550A27 502024 CSB.250

LGB 22 230B27 502182 CSB.250

LGB 22 330A27 502178 CSB.250

LGB 41 258A27 502179 CSB.250

LGC 22 002C271 502180 CSB.250

LGK 16.322A27 502113 CSB.250

LGK 16.622A27 502060 CSB.250

LGK 16.635A27 502114 CSB.250

LME 21 230A2 502012 CSB.250

LME 22 232A2 502017 CSB.251

LME 11 330A2 502010 CSB.250

LME 21 120A2 502011 CSB.250

LME 21 33A2 502013 CSB.250

LME 21 35A2 502014 CSB.250

LME 21 55A2 502015 CSB.251

LME 22 131A2 502016 CSB.251

LME 22 233A2 502018 CSB.251

LME 22 331A2 502019 CSB.251

LME 23 331A2 502020 CSB.251

LME 23 351A2 502021 CSB.251

LME 44 056A2 502022 CSB.251

LME 44 057A2 502023 CSB.251

LMG 21 230A27 see 502012 CSB.251

LMG 21 330B27 see 502013 CSB.251

LMG 22 233A27 see 502018 CSB.251

LMG 22 330A27 see 502019 CSB.251

LMO 24 111A2 502385 CSB.247

LMO 44 255A2 502383 CSB.247

LMO 54 200B2BU 420035 CSB.247

LMO 54 200B2BU 420035 CSB.247

LMO 54 210B2V 424005 CSB.247

LMO 54 210B2V 424005 CSB.247

LMO 64 302A2B 432022 CSB.247

LMO 82 100C2WH 407024 CSB.247

LMO 82 100C2WH 407024 CSB.251

LMO 82 100C2WH 407024 CSB.247

LMO14 111A2 ou B2 502006 CSB.247

LMO14 111A2 ou B2 502006 CSB.247

LOA 14 171B2V 424004 CSB.247

LOA 24 502052 CSB.247

LOA 26 502049 CSB.247

LOA 36 502048 CSB.247

LOA 44 see 502383 CSB.247

LOK 16 250A27 502056 CSB.247

PACT

ROL

CSA 12 448065 CSB.253

CSA 6 448066 CSB.253

CSS 01-24R/E 448050 CSB.253

CSS01.12 448064 CSB.253

CSS01-12SJV11 448062 CSB.253

CSS01-24JV03 448063 CSB.253

P14 110 AL 443010 CSB.253

P16 AFT 448014 CSB.253P16 HIJ 409701 448010 CSB.253P16B 402701 see 448009 CSB.253P16C /FL402801 see 448005 CSB.253P16D /402901 448005 CSB.253P16DI / S (NF) 400601/V03 448002 CSB.253

P16DI /400601 448001 CSB.253

P16FI (CE)406203 448007 CSB.253

RIEL

LO

483 SE see 404894 CSB.252

503 SE 404062 CSB.252

508 SE 404067 CSB.254

509 SE 404019 CSB.254

520 SE 404071 CSB.254

522 RBO 404021 CSB.254

525 SE 404068 CSB.254

530 SE 404894 CSB.254

531 SE 404895 CSB.254

535 RSE 404025 CSB.254

550SE =550 SMD 404640 CSB.254

552SE 404265 CSB.254

553SE 404638 CSB.254

555SE 404024 CSB.254

MG 569 404020 CSB.254

RMG88.62A2 404268 CSB.254

RV

05125001 Type 448002 CSB.255

05125004 Type 453009 CSB.255

0514 Type 453005 CSB.255

SATR

ONIC

Elcopen Analyser defect 402025 CSB.255

Elcopen Analyser defect 402025 CSB.257

DKG 972 507049 CSB.257

DKG 972 507049 CSB.257

DKG 972 mod 21 507065 CSB.257

DKO 970 507009 CSB.255

DKO 972 507012 CSB.255

DKO 974 507014 CSB.255

DKO 976 507015 CSB.255

DKW 972 507059 CSB.255

DKW 972 + prolong. 507060 CSB.255

DKW 976 507061 CSB.255

DKW 976 + prolong. 507062 CSB.255

DMG971 507063 (except Guillot) CSB.257

FFW 930 FIOUL - GAZ 507320 CSB.257

EM41 Kit replace-ment relay 402024 CSB.257

ER1 Kit replace-ment relay voir 402023 CSB.240

ER1H Kit replace-ment relay 402023 CSB.240

MMG 810-33 507056 CSB.257

MMG 811-63 507058 CSB.257

MMI 810-33 507037 CSB.257

MMI 810-35 507034 CSB.257

MMI 811-35 replaced by 507063 (except guillot) CSB.257

MMI 812-23 replaced by 507033 CSB.257

MMI 812-33 replaced by 507033 CSB.257

MMI 813.1 mod 23 507042 CSB.257

MMI 815 mod 10 replaced by 507049 CSB.257

MMI 815 mod 5 replaced by 507049 CSB.257

MMI 962-23 507033 CSB.257

MMO 872

replaced by 507060 + (Detector IRD1010 following brand if IRD810 or 910 or 911 in position or cell UVD codes 507003)

CSB.255

MMO 876

replaced by 507062 + (Detector IRD1010 following brand if IRD810 or 910 or 911 in position or cell UVD codes 507003)

CSB.255

SG 113 406009 CSB.257

SG 513 406020 CSB.257

SATR

ONIC

SH 113 406013 CSB.255

SH 213 mod C1 406019 CSB.256

TF 801 507005 CSB.254

TF 802 507006 CSB.254

TF 804 507007 CSB.255

TF 830 507051 CSB.255

TF 830.3 507064 CSB.255

TF 832 507053 CSB.255

TF 834 see 507001 CSB.255

TF 834.3 507001 CSB.255

TF 834E.3 see 507001 CSB.255

TF 836 507050 CSB.255

TF 840 507054 CSB.255

TF 844 507057 CSB.255

TF 874 405002 CSB.255

TF 974 507016 CSB.255

TFI 812-2 maxi 120 Kw mod 10 507043 CSB.257

TFI 812-2 maxi 350 Kw mod 5 507041 CSB.257

TFI 812-2 mod 10E replaced by 507049 CSB.257

TMG 740.3 type 32-32 replaces TMG 740.2 type 32-32

507032 CSB.257

TMG 740.3 type 43-35 replaces TMG 740.2 type 45-54

507039 CSB.257

TMO 720-4-35 507020 CSB.255

TTG 760 FN replaced by 507058 CSB.257

TTG 760 FN replaced by 507058 CSB.257

TTG 760-33 replaced by 507056 CSB.257

TTG 760-33 replaced by 507056 CSB.257

TTO 810-35

replaced by 507060 + (cell MZ ref 507101 If cell FZ in position or detector IRD1010 following brand or cel UVD ref 507003)

CSB.255

TTO 836-35

replaced by 507062 + (cell MZ ref 507101 If cell FZ in position or detector IRD1010 following brand or cel UVD ref 507003)

CSB.255

TTO 872

replaced by 507060 + (Detector IRD1010 following brand if IRD810 or 910 or 911 in position or cell UVD codes 507003)

CSB.255

TTO 876

replaced by 507062 + (Detector IRD1010 following brand if IRD810 or 910 or 911 in position or cell UVD codes 507003)

CSB.255

SIT

0.503.501 503009 CSB.258

0.503.501 503010 CSB.258

0.503.501 503011 CSB.258

0.537.002 DMT type 404026 CSB.258

0.537.301 DMT type 431015 CSB.258

0.577.009 503002 CSB.258

0.577.211 503005 CSB.258

0.577.304 503007 CSB.258

0.577.308 503003 CSB.258

0.577.311 503004 CSB.258

0.577.503 471003 CSB.258

0.577.504 503001 CSB.258

0.577.701 503013 CSB.258

0.577.702 503012 CSB.258

0.577.705 503006 CSB.258

Classifi cation by brand and manufacturer referencesManufact. Ref. Ref Page Manufact. Ref. Ref Page Manufact. Ref. Ref Page

Control unit

CSB.240

BO

Cont

rol u

nit

BRAHMA CONTROL BOXFUEL type

Fuel burners compatible with a fuel flow less than 30 kg/hour.

Type Pre Purge Safety Time Detection RefCharacteristic : 1 fi ring rateG33/03 15 10 Cell 504006Characteristic : 1 fi ring rateG22/03 only one 15 10 Cell 504019G22/09 only one *

10 10 Cell 504023Characteristic : 2 fi ring ratesGF2/03 only one 15 5 Cell 504018GF3/03 only one 20 5 Cell 504004Characteristic : for FERROLIFR1 10 10 Cell 504044Characteristic : for BALTUROR3/B 20 5 Cell 431131TEC3 10 10 Cell 431260Characteristic : for ELCO

ER1 10 5 Cellsee

402023

ER1H 15 5 Cellsee

402023

** replaces models G22/05, G22/06 and G22/07

NOTE :

Application Ref

ECOFLAM - FRANCO BELGE - FBR - THERMITALsee

504006JOANNES - BALTUR - BIASI - FINTERM - THERMOMATIC - CGA FRANCO BELGE - ECOFLAM - DREIZLER - CHAUFFAGE FRANÇAIS - IDÉAL CLIMA - JUHATHERM - TERMONAFTA -MAZECO - SLCF - SANT ANDRÉA - BLOWTHERM - THERMOMEC

504019

BALTUR - HS FRANCE- FIM - CTC - THERMOMATIC - RADIANT ECOFLAM - FRANCO BELGE - FONDITAL - PORCHER - CTC - CGA 504023JOANNES - THERMOMEC - FINTERM - THERMOMATIC - DREIZLER - JUHATHERM - TERMONAFTA -BLOWTHERM 504018FER-FERROLI 504044BALTUR 431131BALTUR 431260

CELL

1 2 3Description Mark Ref

FC7/R side shot 1 504207FC8/R frontal shot 2 504210TEC3 blue frontal and side shot 3 431259FC13 red frontal and side shot 3 431141FC13AL ELCO pluggable - 402002

BASE

Description RefG22 - GF2 - G22Z 504015

GAS type

1 2Type Pre Purge Safety Time Detection Mark Ref

AT5 15" 5" Io 1 504031AT5/TR1 15" 10" Io 1 504030CM11 20" 10" Io 2 504036CM11F 15" 5" Io 2 504050Characteristic : BPSCM31 30" 10" - 2 504039CM31 30" 5" - 2 504040Characteristic : FRISQUETCM31 15" 5" Io 2 40030Characteristic : SEETCM31F 10" 5" - 1 504005CM32 30" 15" lo 2 504002CM32 20" 10" Io 2 504037Characteristic : SLCFCM32 5" 5" - 2 504038CM32 30" 10" - 2 504051Characteristic : SLCFCM32 - - - 2 504052CM 191.1 - - Io 1 504003CM191.2/T1.5 15" 10" Io 1 504049CM391.2 15" 5" lo 1 40029CM391.2 * 20" 10" Io 1 504035Characteristic : GAZ INDUSTRIE gas relay 20sDM 32 - - - - 504054M300/02 30" 2" Io/UV 1 504027MF2/02 30" 2" Io/UV 1 504033SM11 1.5" 5" Io 2 504024SM152.2 30" 10" lo 1 504001Characteristic : EMATSM191.2 20" 10" Io 1 504048CM391.2 1 504057Characteristic : CHAFFOTEAUXSM192.2 - - - 1 504053SR3/TR01 30" 3" Io/UV 1 504029SR3/02 30" 3" Io 1 504028Characteristic : SLCF

SR3/TR 30" 3" - 1 See504029

SR3/TR15 15" 3" Io/UV 1 504026Characteristic : COUSSEMENTSR3V 20" 3" Io 1 504047TM11-37059010

15" 10" Io - 504042TM31-37065010

15" 10" Io - 504043VE3-2/05 30" 2" Io 1 504025Characteristic : FRISQUETXM11F 15" 5" Io 2 40054Characteristic : ELCOEM41 37201031

30" 3" Io 3 402010Characteristic : CHAUFFAGE FRANÇAISCM391.2 - - - 504060

Characteristic : ACCORONICM31 - - - 504055

Characteristic : (CLIMAIR) ROBURCM32 PR - - - 504056

Characteristic : GUILLOTSM152.2 - - - 504059

Characteristic : replaces OF1OF1PR - - - 504058

* Hydromotrix

3

Control unit

CSB.241

Cont

rol u

nit

BO

NOTE :Application Ref

JOANNES - FINTERM 504031EMAT 504036GEMINOX - PENSOTTI 504050EMAT - BPS - WESPER 504039EMAT- ACCORRONI - NALSON - WESPER 504040EMAT- CHAUFFAGE FRANÇAIS 504037AERMAX- APEN GROUP - GENERFEU - SOLYGAZ - THERMOVUR CHAUFFAGE FRANÇAIS 504038AERMAX 504051ABIG - PENSOTTI - IMMERGAS 504049EMAT - BALTUR FRISQUET - CHAUFFAGE FRANÇAIS 504035EMAT 504048CHAUFFAGE FRANÇAIS 504029CHAUFFAGE FRANÇAIS - ACCORRONI - WESPER 504026JOANNES 504042JOANNES 504043FRISQUET 40054FRANCO BELGE-JOANNES-MAZECO-ECOFLAM - FINTERM CHAUFFAGE FRANÇAIS 504027WESPER-ACCORRONI-EMAT-JOANNES - FINTERM 504033UNIGAS - WESPER - ACCORRONI - BALTUR - ECOFLAM - EMAT-EUROWARM - FRANCO BELGE - AERMAX - APEN GROUPGENERFEU - SOLYGAS - THERMOVUR - CGA - COLLARD TROLART - PORCHER - LAMBORGHINI - SANT ANDRÉA

504028ECOFLAM-JOANNES-BALTUR - PORCHER - CHAUFFAGE FRANÇAIS 504025

CELL

1 2Description Mark Ref

UV 1 Ø22 mm 1 504218FC11 Ø8 mm frontal shot 2 504215

BASE

Description Ref

for MF2 504013for AT5 / TR-CM391 504014for AT5 / SR302 / M300 / VE3-2 504016for SR3 / TR / CM191 504017

CEM ECEE FUEL CONTROL UNITOLD FUEL MODEL

Fuel burners compatible with a fuel flow less than 30 kg/hour.

Type Cell Pre PurgePre

IgnitionPost-

IgnitionSafety Time

Ref

Characteristic : 2 fi ring rates 220VMA 310-1 8205 30" 30" 20" 5" or 10" 501100Characteristic : replaced by MA 510-1MA 410-1 8205 30" 5" 15" 5" or 10" 501010Characteristic : 220VMA 510-1 8205 30" 30" 15" 5" or 10" 501010Characteristic : 380VMA 510-1 8205 30" 30" 15" 5" or 10" 501009

Type Cell Pre PurgePre

IgnitionPost-

IgnitionSafety Time

Ref

Characteristic : 220VMA 610-1 8205 10" 10" 6" 10" 501020Characteristic : 220V replaced by MA 610MA 710 8205 - - 6" 10" 501020Characteristic : single phase 110/220VMA 800 8205 - - - 10" 501040Characteristic : three phase 220/380VMA 803 8205 - - - 10" 501050Characteristic : single phase 220VMA 810 8205 - - - 10" 501060Characteristic : Replaced by MA610MA 910 8205 10" 10" - 10" 501020Characteristic : MA 152.01 8205 24" 24" 18" 5"/8" on request

REPLACEMENT INDEXOLD BOX NEW MODEL Notes

MA 22 MA 26 BASE without replacementMA 25 MA 26 Cell Replaced by 8206MA 86-02 MA 86-05 BASE without replacementMA 87-02 MA 86-05 Cell without replacement

20 type

Pull out equipment. Use with Fuel-oil burner

Type Cell Pre PurgePre

IgnitionPost-

IgnitionSafety Time

Ref

Characteristic : 2 fi ring ratesMA 23 8208 15" 12" 2" 10" 501360Characteristic : replaced by MA 26MA 25 8208 15" 15" 2" 10"Characteristic : Cell 8210/8211MA 26 8206 10" 10" 5" 10" 501300MA 28 8206 - - - 10" 501310MA 29 8206 10" 10" - 10" 501320

PROTECTOBLOC type

Pull out equipment. Use with CEM motor and protectobloc transformer

Type Cell Pre PurgePre

IgnitionPost-

IgnitionSafety Time

Ref

Characteristic : motor 90WMA 72 8205 5" 5" - 10" 501330Characteristic : motor 150WMA 73 8205 5" 5" - 10" 501340

MA 52 8209 12/7" 2" 2" 10" 501375

MA 53 8207 10" 10" - 10" 501374Characteristic : replaced by MA 86-05MA 86-02 8212 7" 10" - 10" 501391MA 86-04 8212 7" 5" 1" 10“ 501391

MA 86-05B 8212 5/7" 5/7" 0,5" 10" 501391

MA 86-11 8212 5/7" 5/7" 0,5" 10" 501392Characteristic : replaced by MA 86-05MA 87-02 8212 - - 12" 10" 501391

Control unit

CSB.242

BO

Cont

rol u

nit

CEM ECEE FUEL CONTROL UNIT41/43/45/46/ 55 type

Type Cell Pre PurgePre

IgnitionPost-

IgnitionSafety Time

Ref

Characteristic : 2 fi ring ratesMA 41 8212 15" 15" 40" 5" 501370MA 43 8212 10" 10" 15" 10" 501350Characteristic : Security on stray lightMA 45 8212 10" 10" 3" 10" 501380MA 46 8212 10" 10" 3" 10" 501385

MA 55 8209 10" 10" 3" 10" 501376Characteristic : Used with preheater

MA 55H 8209 10" 10" 3" 10" 501377Characteristic : maintains the tension even if the klixon heater breaks

MA 55R8207/8209

10" 10" 3" 10" 501378Characteristic : ionizationMA 55E - 10" 10" 3" 10" 501379Characteristic : Remote control

MA 55D8207/8209

10" 10" 3" 10" 501373

CELL

1 2 3 5

4 6 7Description Mark Ref

8205 for MA 800/72/73/152-01 types (supplied without fl ange) 1 5012208206 use with MA 26/28/29 (side and frontal shots) 2 5012608207 use with MA 55R - no fl ange 3 5012618208 use with MA 23 and 25 5 5012908209 use with MA 23 / 25 / 52 / 55 4 5015008210 use with MA 26/28/29 (side Ø17 shots) 2 see 5012608211 use with MA 26/28/29 (side Ø14 shots) 7 5015108212 use with MA 86/ 41/43/45/46 6 5015208212 RR same model extended for GIANOLA 6 501530

BASE

1 2 3Description Mark Ref

S801 for MA 800/803/810 1 501200SP06 for MA 152.01 - GE 232/236 3 501202S20 for all MA 20 types 2 501250S401 for MA 40 and 55 types 2 501252S72 for MA 72 2 501255S73 for MA 73 - 501256S407 for MA 52 2 501257S803 for MA 803 exclusively 1 501410

CEM ECEE CONTROL UNITGAS FLAME

Pull out equipment - Transistor amplifier detects gas flame with a ionization electrode.

FEATURES : � Monophased voltage : 220V +10% +15% 50Hz � Contact of fl ame relay : 220V 2A � Current of fl ame ensuring a correct operation: between 5 and 120 micro amps � Consumption : 3VA � Ambiant temperature : 50°C maxi � Response time of the fl ame relay : lower than 0,5 second with the appearance and the extinction of the fl ame.

Description Ref

AE 25 ionization detector 501900

GA / GB / GE type

Type Pre PurgePre

IgnitionPost-

IgnitionSafety Time

Ref

Characteristic : Blown air burner

GA 2410 30" - - 5" 501615Characteristic : atmospheric burner

GA 2510 5"/10" - - 5" 501620Characteristic : Used absolutely with an air pressure switchRelay GB 650 replaces completely GE 650 subject to short circuit of the terminals 12 and 13 which do not exist on the GE 650.

GB 650 0" - - 4" 501656Characteristic : ionization sensor

GB 650.1 0" - - 4" 501622Characteristic : blown air burner

GE 143 20" - - 5" 501600Characteristic : atmospheric burner

GE 145 10" - - 5" 501605Characteristic : monotube blown air burner

GE 236-01 60" 3" 3" 2" 501650Characteristic : -

GE 296 - - - - 501601Characteristic : not recyclic

GE 633 3" - 3" - 501630Characteristic : can work with shunt on air manostat

GE 650 10" - - 8" 501656Characteristic : 2 fi ring rates

GE 733 30" - 2" 2,5" 501631GE 735 30" - 40" 4,5" 501632

Control unit

CSB.243

Cont

rol u

nit

BO

GU (UV) type

Control and security equipment with flame monitoring by UV sensitive cell.

Type Pre PurgePre

IgnitionPost-

IgnitionSafety Time Ref

Characteristic : ignition spark controlGU 336-01 60“ - 2“ 4“ 501655

CELL

1 2 3Description Mark Ref

8300 UV Detector 1 5016908301 UV Detector industrial model 2 501691SYLVANIA UV P607.88 - Ø22 mm - 4 pin plugs 3 502312

BASE

1 2 3Description Mark Ref

SP06 for GE 218/230/232/236/650/GB650/ GU330/336 - MA 152.01 1 501202S402 for GE 143 / 145 3 501204S412 for GE 733 / 735 2 501205

SPARK DETECTORLinked to a flame detector circuit that uses ionization electrode, the system detects a flame signaling a spark.It replaces the UV cell for ignition spark detection when the use is compromized.

Description RefDA 51 for GE 633/ 733 501660

SEE THE INSTALLATION DRAFT AT THE END OF THIS CHAPTER

DANFOSS CONTROL BOXBHO 62/64/72/74 type

Type Pre PurgePre

IgnitionPost-

IgnitionSafety Time

Ref

Characteristic : Landis & Gyr switch positionReplaced by 505154 after exhaustion of stocks BHO 62 - 7034/7234 13" 13" 15" 10" see 505156Characteristic : Landis & Gyr switch positionBHO 64.1 - 7037 6" 6" 20" 10" see 505157Characteristic : Danfoss switch positionBHO 62D-7035/7235 13" 13" 15" 10" see 505156

BHO 62/64/72/74 type (continuation)

Type Pre PurgePre

IgnitionPost-

IgnitionSafety Time

Ref

Characteristic : Landis & Gyr switch positionBHO 64 - 7036/7236 13" 13" 15" 10" see 505156Characteristic : electronic box with diagnostic blinking light replaces BHO64BHO 72.10 57H6102 13" 15" 15" 10" 505156Characteristic : electronic box with diagnostic blinking light replaces BHO64.1BHO 72.11 57H6103 16" 20" 20" 10" 505157Characteristic : electronic box with diagnostic blinking light replaces BHO64ABHO 73.10 57H6104 13" 2" 15" 10" 505158Characteristic : electronic box with diagnostic blinking light equivalent LMO44BHO 74.10 57H6105 25" 2" 5" 5" 505159

CELL

Description Ref

LD (6 LUX) 057H 7079 - with length 780 mm 505260LD (6 LUX) lg 65,5mm 057H 7079/7279 - with length780 mm 505263LDS (2 LUX) 057H 7085 - with length 500 mm 505261LDS long 057H 7091 for BENTONE - DEVILLE - HS FRANCE 505262

ADAPTER

Description Ref

BHO 70 ADAPTER KIT 505411

BASE

Description Ref

Base 057H 7010 - 057H 7011 for BHO 61/62/62D/64.1 505401

FRA / FRU type Flame control relay used for fl ame control on semi-automatic installations .

Control unit

CSB.244

BO

Cont

rol u

nit

DANFOSS CONTROL UNITFFW type for FRA / FRU replacement

For fuel or gas, atmospheric or ventilated burner.For semi-automatic installation. � Ionization monitoring or cell UVZ or infrared IRD 1020 detector

Description Ref

FFW FUEL - GAS 507320BASE 507300ZT 870 Transformer 805913AZ5 Pilot burner 708790

DUNGS CONTROL BOXDGAI 19 type

DGAI 19.2 control box for atmospheric gas burner, 220VA - 600 Kw, ionization electrode detection.

Type Pre PurgePre

IgnitionPost-

IgnitionSafety Time

Characte-ristic

Ref

DGAI 19.2 4" 5" 4" 13"/8" - 509000DGAI 69 50" 1" 0" - - 509005

VDK / VPS / W-F

1 2 3

4

TypePre

PurgePre

IgnitionPost-

IgnitionSafety Time

Mark Ref

VDK200A 02 type - - - - 1 509001VPS504 02 type - - - - 2 509003VPS504 04 type - - - - 3 509004W-FM20 V3.02 502

- - - 2/5" 4 407103

ELESTA CONTROL BOX ACCESSORYReplacement cell

Description Ref8209 Fuel oil fl ame control cell /all types of control boxes 501500

HONEYWELL CONTROL BOXS4565 GAS type

TypePre

PurgePre

IgnitionPost-

IgnitionSafety Time

Ref

Relay used by GEMINOX

S4565 A 2027 - - - - 508003Relay used by DE DIETRICH - RADIANT

S4565 A 2019 - - - - 508026Relay used by DE DIETRICH - ZAEGEL HELD- ST ROCH -COUVIN

S4565 A 2035 - - - - 508050Relay used by CHAFFOTEAUX - ZAEGEL HELD

S4565 A 2050 - - - 5" 508021Relay used by ACV

S4565 A 2068 - - - - 508053S4565 AD 2080 - - - - 508079Relay used by ROCA

S4565 A 2076 - - - - 508082Relay used by RIELLO - BERETTAS4565 B 2066 replace S4565 B 2017

- - - - 404049

Relay used by RIELLO - SIME - CALORTECNICA

S4565 CF 1052 - - - - 508063Relay used by RIELLO

S4565 RF 1000 - - - - 508077Relay used by DE DIETRICH - CICH - IDEAL STANDARD - APEN GROUP CALORTECNICA - THERMITALS4565 C 1025 - - - - 508058Relay used by VIESSMANN

S4565 C 1132 - - - - 508075Relay used by ACTI - SOLARONICS-GUILLOT-GAZ INDUSTRIE

S4565 D 1007 - - - - 508047Relay used by GEMINOX

S4565 AD 2072 - - - - 508004S4565 BM 1080 - - - - 508072S4565 DM 1045replaced by S4565 DM 1086

- - - - 508048

Relay used by RADIANT SPACE RAY

S4565 P 2024 - - - - 508008Relay used by FERROLI

S4565 AD 2056 - - - - 508016S4565 CD 2029 - - - 10" 508002Relay used by SIME - UNICAL - SAUNIER DUVAL (THELIA 30E)

S4565 AF 1007 - - - - 508054Relay used by CHAUFFAGE FRANÇAIS

S4565 AF 1064 - - - - 508060Relay used by FRANCO BELGE

S4565 BD 2021 - - - - 508073Relay used by DE DIETRICH - IDEAL CLIMA

S4565 BF 1005 - - - - 508052Relay used by DE DIETRICH

S4565 SD 2005 - - - - 508069Relay used by SOLARONICS

S4565 BF 1047 - - - - 508051Relay used by THERMITAL - VIESMANN

S4565 BF 1054 - - - - 508074Relay used by IDEAL CLIMA- AO SMITH - CHAPPEE -IDEAL STANDARD- THERMITAL

S4565 BF 1062 - - - - 508029

Control unit

CSB.245

Cont

rol u

nit

BO

S4565 GAS (continuation)

TypePre

PurgePre

IgnitionPost-

IgnitionSafety Time

Ref

Relay used by DE DIETRICH - OERTLI - ROCAS4565 BF 1112 - - - - 508043S4565 BF 1161 - - - - 508071Relay used by UNICALS4565 CD 1021 - - - - 508076S4565 DF 1050 - - - - 508078Relay used by BIASI - MANAUT - RIELLO - ALLIANCES4565 DD 1003 - - - - 508081Relay used by UNICAL - APEN GROUPS4565 DM 1029 - - - - 508064Relay used by RIELLO - DOMUS- HERMANS4565 CF 1045 - - - - 508001Relay used by DEVILLE-ZAEGEL HELD- ST ROCH COUVINS4565 CF 1060 - - - - 508046Relay used by BALTUR - HERMANNS4565 DD 1045 - - - 10“ 431171Relay used by BERETTAS4565 QM 1012 - - - - 508065Relay used by GENERFEUS4565D1023 508084Relay used by ZAEGEL HELDS4565CD2037 508083

S4560 / S4561 /S4562 /S4570 GAS type

Type Pre PurgePre

IgnitionPost-

IgnitionSafety Time

Ref

Relay used by ACV - INOX G-GES4560 A 1024 - 4" 2,5" 5" 508019Relay used by FRANCO BELGE - BONGIOANNIS4560 A 1032 - 4" 2,5" 10" 508035Relay used by ROCAS4560 B 1006 - 4" 2,5" 10" 508057Relay used by NESTOR MARTIN - GUILLOT - ATLANTICS4560 B 1022 - 4" 2,5" 5" 508028Relay used by BUREXS4560 B 1048 - - - - 508009Relay used by SOLARONICS - GUILLOTS4560 B 1063 - 4" 10" 25" 508036 -S4560 C 1004 - - - - 508062Characteristic : DEVILLES4560 C 1038 8" 4" -- 5" 508024Characteristic : UNICAL - ACCORRONI - AO SMITH - ATI -BOSCHETTI - ICIS4560 C 1053 24" 4" - 10" 508038Characteristic : burner with GEMINOX fan ground boiler w/burner (replaces S4560 D 1028)S4560 D 1077 10" 35" - 5" 508020Characteristic : ACTICharacteristic : ACTI - SOLARONICS - INTERCALS4560 D 1135 24" 4" - 25" 508039Characteristic : CHAPPEES4560 D 1143 16" 4" - 25" 508034Characteristic : -S4560 D 1150 - - - - 508059Characteristic : GEMINOXS4560 M 1036 - - - - 508025

S4560/S4561/S4562/S4570 GAS type (continuation)

Type Pre PurgePre

IgnitionPost-

IgnitionSafety Time

Ref

Characteristic : NESTOR MARTINS4560 CB 1022 - - - - 508012Characteristic : UNICAL - SANT ANDREA - FER - FERROLIS4561 A 1007 - - - - 508056Characteristic : FER - FERROLIS4561 A 1015 - - - - 508040Characteristic : FER - FERROLI - VAILLANTS4561 B 1013 - - - - 508042Characteristic : IDEAL CLIMA - BALTURS4561 B 1005 - - - - 508041Characteristic : CHAUFFE FRANÇAIS - FERROLIS4561 B 1039 - - - - 508007Characteristic : FERROLIS4562 A 1055 - - - - 508005S4562 C 1069 - - - - 508006S4562 DM 1006 - - - - 40503Characteristic : AUERS4570 AS 1012 - - - - 508030Characteristic : DE DIETRICHS4570 BS 1002 - 17" 1" 10" 508011S4570 BS 1036 - 17" 3" 10" 508031S4570 LS 1026 - - - - 508066Characteristic : SOLARONICS - GUILLOTS4570 BS 1010 - - - - 508027Characteristic : FRANCO BELGES4570 BS 1028 - - - - 508067Characteristic : SOLARONICS - GUILLOTS4570 LS 1000 30" 35" 1" 5" 508033Characteristic : REZNOR-GAZ INDUSTRIE-SOLARONICSS4570 LS 1059 15" - - 5" 454064Characteristic : SOLARONICSS4570 LS 1091 - - - - 508086

CONTROL and FLAME SECURITYfor HONEYWELL INDUSTRIAL BURNERS

CELL

1

2

Description Mark RefUV Cell C7027A1049 Monoblock tube frontal shot IP677 Fixing 1/2“ NPT - Cable 2,4m - Temperature -18 to +102°C

1 508202

UV Cell C7027A1056 Monoblock tube frontal shot IP677 Fixing 1/2“ NPT - Cable 2,4m - Temperature -18 to +102°C

1 508203

UV Cell C7027A1064 Monoblock tube frontal shot IP677 Fixing 1/2“ NPT - Cable 7m - Temperature -18 to +102°C

1 508204

UV Cell C7027A1023 Monoblock tube frontal shot IP677 Fixing 1“ NPT - Cable 1,8m - Temperature -18 to +121°C

2 508205

UV Cell C7061A1020-ST001 IP677 - Temperature -40 to +80°C with amplifi er lens 3 508206

3

Control unit

CSB.246

BO

Cont

rol u

nit

CONTROL and FLAME SECURITYfor HONEYWELL INDUSTRIAL BURNERS PROGRAMMER

Universal programmer pluggable to Q 7800 baseAPAVE D 15/97 -43.2 approved

Description Ref

EC7850A1072 - 230Vac - post purge : 2s 508227

BASE

For 7800 type

Description Ref

Q7800A1005 plastic version 508208

PRE-VENTILATION CARD

Range of purge timer

Description Ref

ST7800A1013 - 7s 508224ST7800A1039 - 30s 508225

AMPLIFIER

For UV : R7824/47/49/61/86 - Pluggable - additional modules

Description Ref

R7849A1023 standard - 2s - for C7027/35/44 detector 508219R7861A1026 Auto-verifying - 2s - for C7061 detectorAPAVE D 15/97 -43.2 approved 508220

For flame electrode : R7847A/B - Pluggable - additional modules

Description Ref

R7847A1033 standard - 2s - for C7012A/G detector 508217R7847B1031 Auto-verifying - 2s - electrodes detectorAPAVE D 15/97 -43.2 approved 508218

MANUAL REMOTE RESET MODULE

Description Ref

S7820A1007 only remote reset 508222

RELAY

Primary relay with reversing switch

Description RefR4343D1041-ST005 Standard amplifi er incorporated - Ioniza-tion 115/230Vac - 2 reversing switches : 4A cos ϕ 6,35 508209R4343E1048-ST005 UV standard amplifi er incorporated for mini Cell C7027 or C7035 - 115/230Vac - 2 reversing switches : 4A cos ϕ 6,35

508210

Half automatical industrial relays - Universal relay- 115/230VAC Start auto control for pluggable amplifier R72xx - 2 independant relays

Description RefR4348B1057 Output and LED meter contact rating 4-20MA Gives an indication of fl ame current strength (onlynfor measure not for security) IP54 APAVE D 15/95 -40.1 approved

508212

R4348B1008 Standard model - without fl ame current jack socket - IP54 508211

BASE

Description Ref

Base box R4348 508200

AMPLIFIER

1 2

For UV : R7824/47/49/61/86 - Pluggable - additional modules

Description Mark RefR7323B1026 standard (U.V.) - 2s - for detector C7027/35/44 1 508216R7323B1018 standard (U.V.) - 2s 1 508215R7061A1016 Auto-verifying (U.V.) - 2s - for detector C7061 APAVE D 15/86 -10.3 approved 2 508213R7247A1005 Auto-verifying (U.V.) - 2s - for detector C7012E APAVE D 15/95 -40.1 approved 2 508214

SEAL CONTROL PROGRAMMER

Air pressure control LED display

Description Ref

A4021A1002 230 Vac 508201

BASE

Description Ref

ZL030001 Seal control base 508226

Control unit

CSB.247

Cont

rol u

nit

BO

ADAPTER

Adapter 4-20mA for M9184 (internal connection)

Description Ref

Q7230A005 4 - 20mA 508207

LANDIS & GYR STAEFA - SIEMENS FUEL CONTROL BOXLOA type

Type Pre PurgePre

IgnitionPost-

IgnitionSafety Time

Ref

Characteristic : Special VIESSMANN

LOA 14 171B2V - - - - 424004Characteristic : alternative for LOA 22 + decrease voltage security

LOA 24 13" 13" 0/13" 10" 502052Characteristic : Will replace LOA 24 when no more available.

LMO 24 111A2 (1)(2) 16" 15" 10" 10" 502385

Characteristic : Special CHAPPEE - IDEAL STANDARD

LMO14 111A2 ou B2 (1)(2) 16" 15" 10" 10" 502006

Characteristic : Special WEISHAUPT

LMO 82 100C2WH (1)(2) - - - 3s gas

5s fuel 407024

Characteristic : Special BUDERUS

LMO 54 200B2BU (1)(2) - - - 7s 420035

Characteristic : Special VIESSMANN

LMO 54 210B2V (1)(2) - - - - 424005

Characteristic : decrease voltage protection

LOA 26 13" 13" 15" 10" 502049Characteristic : 2 fi ring rates + 30 kg/h

LOA 44 25" 25“ 5/8" 5" see 502383

Characteristic : Will replace LOA 24 when no more available.

LMO 44 255A2 (1)(2) 26" 25" 5" 5" 502383

Characteristic : Special BENTONE

LMO 64 302A2B (1)(2) - - - - 432022

Characteristic : voltage light - fl ame light

LOA 36 13" 13" 15" 10" 502048

(1) Automatic failure detection box.3 blinking different colors signal a defect.(2) Use with QRB1 or QRC1. No needs to replace the base.

LAL ... /LOK type

Type Pre PurgePre

IgnitionPost-

IgnitionSafety Time

Ref

Characteristic : 3 stages remote lockout + Switch for airdamper QRB1

LAL 1.25 22.5" 27.5"/2.5" 22,5"/5" 5" 502091Characteristic : 3 stages remote lockout +Switch for airdamper RAR or QRB1

LAL 2.14 14" 14"/2" 10"/4" 5" 502092LAL 2.65 67.5" 27.5"/2.5" 22.5"/5" 5" 502093Characteristic : photo resistant or electric cell + air pressure + QRB1

LAL 2.25 27.5" 27.5"/2.5" 22,5"/5" 5" 502094Characteristic : Detection by RAR 7 or RAR 6

LOK 16 250A27 27.5" 27.5"/2.5" 15" 5" 502056

ADDITIONAL TECHNICAL OVERVIEWIMPORTANT : For telegestion, replace LAL by LOK 16.In that case move the polarization pins.

Box typeLAL LOK 16

250A271.25 2.14 2.25 2.65

Intermittent functioning X X X X -

Permanent functioning - - - - X

Voltage 230V X X X X X

Box model M X X X X X

Contact MO = motor (synchrone)

X X X X X

Programmable starter X X X X X Decrease voltage Protection X X X X X Remote control release X X X X XCell QRB X X X X -Cell QRB X X X X -

Cell RAR - X X X X

Contact 2 Ev X X X X X

Contact air fl ap X X X X X

Temperature adjustment or boiler pressure

X X X X X

LAE typeNOTE : Adjustable preventilation from 8" to 63".Total preventilation and post ventilation cannot exceed 90" (when Pre-purge = 8", post-purge = 82" etc...)Adjustable security delay from 0“ to 9"

Type Pre PurgePre

IgnitionPost-

IgnitionSafety Time

Ref

LAE 1/1355 30" 3" -: 5" 502172

FLAME DETECTORYellow flame detector box for fuel oil burner flame control. Use with cell RAR7 and RAR8.Use with program LEC1.

Description Ref

LAE 10 502171

Control unit

CSB.248

BO

Cont

rol u

nit

LANDIS & GYR STAEFA - SIEMENS FUEL CONTROL BOXCell

1

Description Mark Ref

QRB1A with cable L800mm for WEISHAUPT lg 65mm 1 407137QRB1A with AMP II n°9 for WEISHAUPT lg 65mm 2 407144QRB1B with AMP III for CHAPPEE - IS - BAXI Cell lg 50mm- lg 190mm 2 401061QRB1A with AMP III n°13 for WEISHAUPT lg 65mm 3 407143QRB1A for LAI - LAB- LAC - LOA - and LAL1 Ø9 mm 4 502221QRB1A A068B70B 4 502025QRB1B A048B70B 4 502026QRB1B A068B70B 4 502027QRB1B D022X20B 4 502029QRB1B D025B40B 4 502031

5 6 7

8 9Description Mark Ref

QRB1B A148B70B - 502226QRB1B high sensibility 5 502222QRB1B wire 1,50 m 6 502224QRC1 UV sensitive.Use with boxes ref: LOA & LMO (except LOA 25 & LOA 28) 7 502235

QRB1B specifi c CUENOD and ELCO 8 502223QRB1B 4MST with AMP II for KORTING 9 502225QRC1.A1.170C27A 7 502234

10 11 12

Description Mark Ref

QRB1B C036B40A 13 502028QRB1B 4MST with AMP II for WEISHAUPT Lg 56 mm 10 407011QRB1B with AMP III n°13 for WEISHAUPT Lg 65 mm 10 407043QRB3 for LAI - LAB - LAL1 - LOA - LAC - LAE 11 502230RAR7 selenium cell replaces RAR2 12 see 502261

RAR8 selenium cell replaces RAR3 12 see 502261

RAR9 Cell 12 502261

BASE

1 2Description Mark Ref

AGK 86.10A27 for Weishaupt WG30 2 407086AGK4 104.13450 for LAE 10 - LAI - LAB - LF1 - LFM height 20 mm 1 502350AGK4 104.90250 for LAI - LAB - LF1 - LFM - height 27 mm 1 502351

2 3 4

13

BASE

1 2Description Mark Ref

AGK11 for LOA - LGA - LMO 2 502352AGK85.22A27 for WEISHAUPT 2 502355AGM410.490500 for LAL 1 502367AGM16 for LOK16 - 502354

ADAPTER KF type

Allows the replacement of old control boxes without re-wiring LAI - LAB - LAC LFA - LFB - LFi - LFM

Description Ref

KF 8819 in replacement of LAI et LAB by LOA 502370KF 8826 in replacement of LAL 12.1 by LOA 24 (MONARCH) QRB1 407300KF 8852 in replacement of LFI 7 by LGB 502378KF 8880 in replacement of LFM by LGB2(burner with fan) 502360KF 8862 in replacement of LFM by LB41 (atmospheric burner) 502381IMPORTANT : Fix these adapters between the new box and the old box base

CONTROL BOX TESTERLANDIS & GYR - STAEFA - SIEMENS KF 8840 type

The fixed adapter, located between the base and the box, indicates the activa-tion program, and at the same time measures the voltage control through the pin plugs. There are 2 measuring sockets to control the flame signal and one simulation selector

Description Ref

KF 8840 TESTER 502199

LAI / LAB / RBQ REPLACEMENT INDEXThe adapters are necessary when out- of -production security boxes need to be replaced.The new KITS, are easy to fix and avoid the replacement of the base ; they are designed to keep the same height position.When a replacement is needed, a wiring modification may be necessary : the instructions are then provided.

OLD RELAY ADAPTATION KIT

RefType New Relay Primary all Adapter

Cell

with noneLAI 1/2/4 - LAB 16.3 type 01

LOA 24 QRB1/3 KF 8819 - X 502062LAI 12 type 01 LOA 24 QRB1/3 KF 8826 - X LAI 12.1 LOA 24 QRB1/3 KF 8826 - X LAB 1 LOA 44 QRB1/3 KF 8819 - X 502063LAB 15 / 15.1 LOA 44 QRB1/3 KF 8819 - X 502063LAB 16.3 type 3 LOA 44 QRB1/3 KF 8819 X 502063RBQ 31 / 34 LAL 1.25 QRB3 re-wire - - - RBQ 33 LAL 1.25 QRB3 re-wire - - -

Control unit

CSB.249

Cont

rol u

nit

BO

LAI / LAB by LOA type REPLACEMENT KIT

LOA 21 & LOA 22 , have been stopped in january. 1997.Those are replaced by ref: LOA 24 ,CE conform.

Description for Replacement KIT Composition Ref

KIT LAILAI 1 / LAI2 / LAI 2.2/ LAI 4 /LAB 16.3 type 01

LOA 24 + KF 8819no cell replacement 502062

KIT LABLAB 1/ LAB15 /15.1

LAB 16.3 type 03LOA 44 + KF 8819no cell replacement 502063

LANDIS & GYR STAEFA - SIEMENS FUEL CONTROL BOXLAC 1/2/3 REPLACEMENT INDEXThe adapters are necessary when out-of-production security boxes need to be replaced.The new KITS, are easy to fix and avoid the replacement of the base ; they are designed to keep the same height position.When a replacement is needed, a wiring modification may be necessary : the instructions are then provided.

Old boxADAPTATION KIT

Replaced by Primary all Adapter

Characteristic : -

LAC 1.013 LAL 2.14 QRB1 -

LAC 1.025 LAL 1.25 QRB1 -

LAC 1.035 LAL 1.25 QRB1 -

Characteristic : QRB1 & QRB3 are used according to burner type.

LAC 1.125 LAL 2.65 QRB1/3 -

LAC 2.013 LAL 2.14 QRB1 -

LAC 2.025 LAL 1.25 QRB1 -

LAC 2.035 LAL 1.25 QRB1 -

Characteristic : QRB1 & QRB3 are used according to burner type.

LAC 2.125 LAL 2.65 QRB1/3 KF 8808

Characteristic : -

LAC 3.013 LAL 2.14 QRB1 KF 8810

Characteristic : If there is any control connection to screw 8 or 14, replace the LAC3 with a LAL 2.25 type.

LAC 3.025 LAL 1.25 QRB1 KF 8810

Characteristic : If there is any control connection to screw 8 or 14, replace the LAC3 with a LAL 2.25 type.

LAC 3.035 LAL 1.25 QRB1 KF 8810

Characteristic : QRB1 & QRB3 are used according to burner type.

LAC 3.125 LAL 2.65 QRB1/3 KF 8808

RAQ / RAI / LAB10 REPLACEMENT INDEXOUT OF PRODUCTION boxes. Base re-wiring and a new cell are necessary

Old box Replaced by Cell

RAQ 15.1 LAE 1/1 355 RAR 7/8/9

RAQ 15.2 LAE 1/1 355 RAR 7/8/9

RAQ 15.3 LAE 1/1 355 RAR 7/8/9

RAQ 10.1/2 LAE 10 RAR 7/8/9

RAI 20 LAE 10 RAR 7/8/9

RAI 15.1 LAE 1/1 355 RAR 7/8/9

RAI 15.3d LAE 1/1 355 RAR 7/8/9

RAQ 15.4d LAE 1/1 355 RAR 7/8/9

LAB 10 LAE 10 RAR 7/8/9

LANDIS & GYR STAEFA - SIEMENS MIXED CONTROL BOX

MIXED LEC type

Scheduler for double monitoring with detector LAE 10 or LFE 10.NOTE : Adjustable preventilation from 8“ to 63“.Total Preventilation time + post-ventilation can not exceed 90“ (when Preventilation = 8“, post-ventilation = 82“ etc...)

TypePre-

PurgePre-

IgnitionPost-

IgnitionSafety Time Ref

LEC 1/8 853 30" 3" - 5" 502173

MIXED LFE10 type

Blue flame detector used for fuel or gas. Link with LEC program.

Description Ref

LFE 10 502170

BASE

1Description Mark Ref

AGG4 104.1713 (AE) 1 502364AGK4 104.13450 for LFE 10 2 502350

RWA REPLACEMENT INDEXOld box Replaced by Cell

RWA2 LEC1 NONE

LANDIS & GYR STAEFA - SIEMENS GAS CONTROL BOXLFE type

TypePre-

PurgePre-

IgnitionPost

IgnitionSafety Time

Ref

LFE 50 * - - - - 502001NOTE : * Control box of flame that works with a LEC1 relay. The direction is done with a QRA50M (frontal shot) or QRA51M (side shot)

2

Control unit

CSB.250

BO

Cont

rol u

nit

LANDIS & GYR STAEFA - SIEMENS GAS CONTROL BOXLFI 7 / LFM 1 type

LFI relay provides automatic activation and monitoring of blown air gas burner (monotube 1 firing rate). LFM relay is used for automatic control and activa-tion of gas burner (with 1 or 2 stages; with or without a fan).

TypePre-

PurgePre-

IgnitionPost

IgnitionSafety Time

Ref

Characteristic : instant steam generator LFI 7-13 8" 0,5" 3" 3"Characteristic : -LFI 7-33 30" 0,5" 3" 3"Characteristic : atmospheric burnerLFI 7-35 30" 0,5" 5" 5"Characteristic : ignition spark controlLFM 1-33F 30" 0,5" 3" 3"Characteristic : atmospheric burnerLFM 1-35 30" 0,5" 5" 5"

LFL type

Flame control by UV or ionization

Type Pre Purge Pre Ignition Post-

Ignition Safety Time

Ref

Characteristic : steam generator LFL 1.122 14" 4" 2" 2" 502107Characteristic : - LFL 1.133 14" 4" 3" 3" 502004Characteristic : 2 ionization sensors possible LFL 1.148 14" 2" 4" 4" 502112Characteristic : burner 1 or 2 tubes 3 fi ring rates remote control release + air damper ionization or UV LFL 1.322 37,5" 4"/2" 2"/4" 2"/4" 502101 LFL 1.335 37,5" 5"/2,5" 2,5"/5" 2,5"/5" 502102Characteristic : burner 1 or 2 tubes 3 fi ring rates remote control release + air damper ionization or UVLFL 1.622 66" 4"/2" 2"/4" 2"/4" 502110LFL 1.333 32" 6" 3" 3" 502109With spark detection by QRE1. Control by ionization or UV. Characteristic : burner 1 or 2 tubes 3 fi ring ratesremote control release+ air damper ionization or UV monitoringLFL 1.622F 66" 4"/2" 2"/4" 2"/4" 502103Characteristic : -LFL 1.322F 37,5" 4"/2" 2"/4" 2"/4" 502104Characteristic : gas and mixedLFL 1.635 67,5" 5"/2,5" 2,5" 2,5" 502106

LGB 21 / 22 / 41 typeBox for small or medium power gas burners, with orwithout a fan. Flame monitoring by ionization sensor or UV sensor. Lower voltage Security . Remote control release . Air pressure control when startup.When operating without any motor, it is necessary to cable on plug 3 a resistance type AGK 2500 A 27 (except for LGB41) When a LFI is replaced you must adapt the monitoring module UV A6Q2.1A27 ref 502321.

Type Pre Purge Pre

Ignition Post-

Ignition Safety Time

Ref

Characteristic : steam generator 2 fi ring rates

LGB 21 130A27 7" 2" 2,4" 3" 502205Characteristic : 2 fi ring rates

LGB 21 330A27 30" 2" 2,4" 3" 502177LGB 21 350A27 30" 2" 4" 5" 502206

see replacementindex page CSB.252

LGB 21 / 22 / 41 type (continuation)

Type Pre Purge Pre

Ignition Post-

Ignition Safety Time

Ref

Characteristic : -LGB 21 550A27 - - - - 502024

Characteristic : 2 fi ring progressive ratesLGB 22 330A27 30" 3" 2,4" 3" 502178Characteristic : BENTONELGB 22 230B27 - - - - 502182

Characteristic : 2 fi ring rates /atmospheric burnerLGB 41 258A27 18" 2" 4" 5" 502179

NOTE : For the startup with ignition spark control use QRE1 for LGB 21/22 and 41.

LGC 22 type

Type Pre Purge Pre

Ignition Post-

Ignition Safety Time

Ref

Characteristic : Box for wall unit gas boilerspecifi c to BROTJE (270961) LGC 22 002C271 1,5" - - 10" 502180

LGK type

LGK 16.622A27 self-controled detection circuit, linked to a ionization sensor or UV cell like QRA 53/55 ; same program as LFL boxesNOTE : LGK 16 Necessary for self or remote heating plant. It replaces the LFL relay.

Description Ref

LGK 16.622A27 502060LGK 16.322A27 502113LGK 16.635A27 502114

LME type

Can replace LGB and LMG boxes and detect any defect (blinking reset button) When operating with UV sensor, you must use a control module (AGQ3 Ref 502323)

Type Pre Purge Pre

Ignition Post-

Ignition Safety Time

Ref

Characteristic : defect box detectionLME 11 330A2 30" 2" - 3" 502010Characteristic : defect box detection replaces LGB 21.130A27 and LMG 21.130B27LME 21 120A2 7" 2" - 3" 502011Characteristic : defect box detection replaces LGB 21.230A27 and LMG 21.230B27LME 21 230A2 20" 3" - 3" 502012Characteristic : defect box detection replaces LGB 21.330A27 and LMG 21.330B27LME 21 33A2 30" 2" - 3" 502013Characteristic : defect box detection LGB 21.350A27 et LMG21.350B27LME 21 35A2 30" 2" - 5" 502014

Control unit

CSB.251

Cont

rol u

nit

BO

LME type (continuation)

Type Pre Purge Pre

Ignition Post-

Ignition Safety Time

Ref

Characteristic : defect box detection replaces LGB 21.550A27 and LMG 21.550B27

LME 21 55A2 50" 2" - 5" 502015Characteristic : defect box detection replaces LGB 22.130A27 and LMG 22.130B27

LME 22 131A2 50" 3" - 3" 502016Characteristic : defect box detection replaces LGB 22.230A27 and LMG 22.230B27

LME 22 232A2 20" 3" - 3" 502017Characteristic : defect box detection replaces LMG 22.330B27

LME 22 233A2 20" 3" - 3" 502018Characteristic : defect box detection replaces LGB 22.330A27

LME 22 331A2 30" 3" - 3" 502019Characteristic : defect box detection replaces LGB 32.330A27

LME 23 331A2 30" 1" - 5" 502020Characteristic : defect box detection replaces LGB 32.350A27

LME 23 351A2 30" 1" - 5" 502021Characteristic : defect box detection replaces LGB 41.255A27

LME 44 056A2 9" 2" - 5" 502022Characteristic : defect box detection replaces LGB 41.258A27

LME 44 057A2 9" 2" - 5" 502023

LMG/ LMO typeThese control boxes can replace the LGB types(the detection and defect analysis).It uses reset switches that blink.example : � flame detection defect - 2 blinks � pressure air defect - 3 blinksThe analysis is stored even when device is off.When operating without any motor, it is necessary to cable on plug 3 a resis-tance type AGK 2500 A 27 (except for LGB41)when a LFI is replaced you must adapt the monitoring module UV A6Q2.1A27 ref 502321.

TypePre-

PurgePre-

IgnitionPost-

IgnitionSafety Time

Ref

Characteristic : defect box detection

LMG 21 230A27 20" 2" - 3" See 502012

LMG 21 330B27 30" 2" - 3" See 502019

LMG 22 330A27 30" 3" - 3" See 502019

LMG 22 233A27 20" 3" - 3" See 502018

Characteristic : Limp mixed gas and fuel for Weishaupt

LMO 82 100C2WH - - - 3" 407024

Cell

1

Description Mark Ref

QRA 2 UV detection cell for gas or mixed burner RED SPOT 2 502310

QRA 2M UV detection cell, same application, high sensitivity GREEN SPOT - 502311

QRA 10C UV Cell - 502308QRA 10MC UV high sensitivity cell - 502309QRA 55 UV Cell of 70 mm for LGK 16 1 502320QRA 50M UV Cell 3 502002QRA 51M UV Cell 4 502003

3 42

LAMP / REPLACEMENT BULB

Description Ref

UV LAMP standard for QRA ref AGR 45 02 11310 502313UV LAMP high sensitivity ref AGR 45 02 0650M 502314

BASE

1Description Mark Ref

AGG4 104.1713 (LFE1) - 502362AGK11 for LOA - LGA - LMO 1 502352AGK 4101 13450 for LFI - LFE10 - LFM - LAE 10 2 502350AGK 4101 90250 same base for these different models height 27 mm instead of 20 mm - 502351LGK16 BASE AGM17 3 502356LFL BASE 4104 0550 - 502366AGK85.22A27 for Weishaupt - 502355

KF ADAPTER

Description Ref

KF 8852 in replacement of LFI 7 by LGB 502378KF 8853K in replacement of LFI 7 by LGB22 502361KF 8880 in replacement of LFM by LGB 2 502360KF 8862 in replacement of LFM by LGB 41 502381

SPARK DETECTORQRE 1 spark ignition electronical detector. Used on burner controlled by ionization whose light fl ow is higher than 15% of the nominal capacity

Description RefQRE 1 see 502032QRE1 150 502032

RC CIRCUITEssential when LFI / LFM et LGA- LGB - LMG are connected to 220V mono electric supply (between 2 phases).

Description Ref

RC circuit 502316

UV MONITORING MODULEAGQ1.1A27 for relay type LGB... LMGAdditional module for gas burner flame monitoring with UV sensor type QRA...Under base assembly.

Description Ref

AGQ1.1A27 for relay type LGB... LMG 502321AGQ3.1A27 for relay type LME 502323

2 3

Control unit

CSB.252

BO

Cont

rol u

nit

LANDIS & GYR STAEFA - SIEMENS GAS CONTROL BOX LFG / LFI / LFM REPLACEMENT INDEXNot necessary to rewire, when replacing

Type Replaced by Primary cell Adapter noneCharacteristic : -

LFG 1.33 LGB21 330A27orLMG21 330A27

502177 or 502007 502350 X

LFI 713 LGB 21 130A27 Io KF8852 X

LFI 733 LGB 21 330A27 orLMG 21 330A27 Io KF8852 X

LFI 735 LGB 21 330A27 Io KF8852 XCharacteristic : Check that terminal 4 stays connected to the old baseFor UV type, add module AGQ ref Diff 502321LFM 1.33 LFM 1.33F LFM1.35

LGB 21 330A27 orLMG 21 330A27 Io/UV

KF8880except

CUENODX

LFM 1.35 LGB 21 350A27 orLGB 22 330A27 orLMG22 330A27

Io/UV KF8880 X

Characteristic : Check that terminal 4 stays connected to the old base.Replacements for atmospheric burners LFM 1.33 LFM 1.33F LFM1.35

LGB 41 258A27 Io KF8862 X

LFC / LFI REPLACEMENT INDEXOLD BOX ADAPTATION KIT

Type Replaced byPrimary

cellAdapter

Cellwith none

Characteristic : -LFC 1.1 LGA 41 173A 27 Sensor Io - - XLFI 5.19 type 02 LGA 41 173A 27 Sensor Io - - XCharacteristic : without ventilator 1 fi ring rateLFI 1 série 02 LGA 41 173A 27 Sensor Io - - XCharacteristic : without ventilator 2 fi ring ratesLFI 1 série 02 LGA 52 150A 27 Sensor Io - - X

LFA / LFB / REPLACEMENT INDEXOLD BOX ADAPTATION KIT

Type Replaced byPrimary

cellAdapter

Cellwith none

Characteristic : when ignition spark detected, use boxes type F+QRE Ref 502315

LFA 2.12LFL 1.122 type 02

Io - - X

Characteristic : (1) when ignition spark detected, use boxes type F+QRE Ref 502315(2) LFA ionization fl ame monitoring(3) LFB UV fl ame monitoringLFA (2) or LFB (3)1.32/ 1.322 (1)2.32 /2.322 (1)

LFL 1.322type 02

Io or UV - - X

4.32/ 4.322 (1) - - XLFA (2) or LFB (3)1.33/ 1.355 2.33/ 2.355 LFL 1.335

type 01Io or UV

- - X

4.33/ 4.355 (1) - - -

LFA (2) or LFB (3)1.62/ 1.622 (1)2.62/ 2.622 (1)

LFL 1.622type 02

Io or UV - - X

4.62/ 4.622 (1) - - XLFA (2) or LFB (3)1.63/ 1.635 2.63/ 2.695

LFL 1.635type 01

Io or UV - - X

LFD REPLACEMENT INDEXType Replaced by Ref

Base for re-wiring ref

Cell

Characteristic :(1) use these models for atmospheric burnersLFD 1.33 type 02

LFL 1.335 or LGB 41 (1)

502102 or 502179 (1)

502366 or 502350

none

LFD 2.35LFL 1.335 or LGB 41 (1)

502102 ru 502179 (1)

502366 or 502350

none

LFD 2.38LFL 1.335 or LGB 41 (1)

502102 or 502179 (1)

502366 or 502350

none

RAI / RAQ REPLACEMENT INDEXOUT OF PRODUCTION boxes. Base re-wiring and a new cell are necessary, when you take a new box.

OLD BOX Replaced by Cell

RAI 15.2 LFE 1/8 853 Io

RAI 15.1 LFE Io or QRA2

RAI 15.3d LFE Io or QRA2

RAQ 10.1 LFE 10 Io

RAI 20 LFE 10 Io or QRA

LDU type CONTROL BOX

The Leak detector LDU11 is designed for double shuttingsgas installations .After each activation cycle, the box programs automatically the seal control, and prevents the burner to start in case of internal leakage

Description Ref

LDU 11 523A27 type 220 volts 502111

PACTROL CONTROL BOXP14 type

Description Ref

P14 110 AL for radiant gas (selfcontrol gas) 443010

P16 type

Range of Control boxes, completely automatic, for atmospheric or air (forced up to 60 kw) burners. The case includes an ignition generator and a single or double electrode .The range of PACTROL P16 controls alternatively the ignition and the flame for burners up to 60 Kw (forced air) or above. Supplied without base.

TypePre

PurgePre

IgnitionPost-

IgnitionSafety Time

Ref

Characteristic : 1 fi ring rate

P16C /FL402801 - 6"-12" - 5" see 448005

Characteristic : 2 fi ring rates

P16D /402901 - 6"-12" - 5"-10" 448005P16DI /400601 - 6"-12" - 5"-10" 448001P16DI / S (NF)400601/V03

- 6"-12" - 5" 448002

P16FI (CE)406203 - 30" - 5" 448007P16 HIJ 409701 - 10" - 20" 448010Characteristic : -

P16B 402701 - - see 448009

P16 AFT - - 448014

Control unit

CSB.253

Cont

rol u

nit

BO

CFR - CSS - CSA type

Type Pre Purge Pre IgnitionPost-

IgnitionSafety Time

Ref

Characteristic : -CSS 01-24R/E 20" - - 7" 448050Characteristic : 2 electrodes ignition and detectionCSS01.12 9" - - 12" 448064Characteristic : same electrode ignition and detectionCSS01-12SJV11 9" - - 12" 448062Characteristic : -CSS01-24JV03 30" - - 24" 448063CSA 12 10" - - 12" 448065CSA 6 10" - - 6" 448066

CONNECTOR

Description Ref

CONNECTOR 10 terminals for P16 448012CONNECTOR 12 terminals for P16 448013

BASE

Description Ref

Base for box CSS01.24 448051

APPLICATION INDEXType Manufacturer

P 16 A / FL 402601 SOLARONICS

P 16 C / FL 402801 FERROLI (NEF) / SOLARONICS / SOLARTUBE/DIFOTHERM

P 16 D / FL 402901 SPAO RAY/FADIME / LAIDETP 16 DI / FL 400601 SCHWANKP 16 DIA / FL 400601 / V07 GENERFEU/KUBBLER

P 16 DI /S (NF) 400601/ V03 GAZ INDUSTRIE / EMAT / DIFOTHERM/FADIME/AIRGARRY/JETTO

P 16 FI (CE) 406203 BABCOCK / AIRCALOP 16 402701 EMATP 16 FIS 406203 / V01 (CE) AIRCALOP 16 H 403402 BABCOCK / SCHWANKP 16 HI - J 409701 SCHWANK / BABCOCKCSS 01 - 24 RE REZNOR / CIATCFR V 401400 -P 14 110 AL GENERFEUCSS 01 - 12 GENERFEUCSS 01 - 12 SJV 11 ETACSS 01 - 24 JV 03 HAMWORTHY / POWELL DUFFRYNCSA 12 SARGICSA 6 SARGI / SMITH INDUSTRIE

RIELLO FUEL CONTROL BOXACCESSORIES for 480 SE

1

Description Mark Ref

Replacement kit / cell 300 5737 1 404185Spare plug for replacement kit 2 404890

503 SE type

NOTE : The RMO 503 SE (new model) with its release button replaces the 503SE, but not the old version of the 502SE.

Type CellPre

PurgePre

IgnitionPost

IgnitionSafety Time

Manufactu-rer ref.

Ref

503SE 2 + 3 34" 8" 7" 5" 300.1150 404062

483/520/522 RBO/530/531 SE/535 RSE type

1

Type CellPre

PurgeSafety Time

Manufacturer ref.

Mark Ref

483 SE* 3 10" 5" see 530 SE - 520 SE** 3 6" 4" 300.1132 Mectron

Four 1 404071

530 SE 3 10" 10" 300.1156 replaces 483 SE 404894

531 SE 3 10" 10"300.1158

for burner with preheater

404895

522 RBO 3 10" 10" 300.3896 for RL28 to 190 burner 2 404021

535 RSE - - -300.8652 for burner

with preheater 404025

* replacement of 483 SE by 530 SE , except when delay timer on 483 SE is out of order (531 SE with Base in that case.)** Replacement box kit + coil

550 / 552 / 553 SE type

Control box for blue flame burner (Gulliver BLU BG1).

Type CellPre

Purge

Pre Igni-tion

Post Igni-tion

Safety Time

Manufac-turer ref.

Ref

550SE =550 SMD *

IRD 5" - - - 300.1168 404640552SE - 8" - - - 300.1174 404265553SE - - - - - 300.1175 404638555SE - - - - - 300.8850 404024* A wiring modification is sometimes necessary.

2

2

Control unit

CSB.254

BO

Cont

rol u

nit

RIELLO FUEL CONTROL BOXCELL

1

4 5

7

Description Mark Ref

Replacement kit of Cell 300 5737 1 404185Spare plug for replacement KIT 2 404890Cell 300 2280 for 483/530/531 SE /520 5 404891Cell 300 7839 for 552 / 553 SE 3 404639Cell 300 7492 for 550 SE 4 404637Cell 300.8646 for 535 SE 6 404088MZ770S Cell 300.2548 7 404098

BASE

1 2Description Mark Ref

BASE 300 2256 for 502/503/505/506/508 SE 1 404061BASE 300 2278 for 483/520/530 SE 2 404889BASE 300 2310 for 531 SE 2 404896

DELAY TIMER

Description Ref

Delay timer 300 2301 G20D 404641

RIELLO GAS CONTROL BOX505 - 506 - 508 SE type

The RMG 508SE with its release button replaces the 508SE, but not the old version of the 505 + 506SE NOTE : Wiring modification supplied with the box

Type CellPre

Purge

Pre Igni-tion

Post Igni-tion

Safety Time

Manufacturer ref.

Ref

508SE Ionizat. 38" - 2,5" 3" 300.1138 404067

509SE ionizat. 35" - 2,5" 3" 300.1139 for FS 10/15/20 404019

2 3

6

525 SE / RMG 88 type

Type Cell Pre Purge

Pre Igni-tion

Post Igni-tion

Safety Time

Manufac-turer ref. Ref

525SE Io 30" - - 5" 300.1164 404068RMG88.62A2 - - - - 3" 301 3073 404268

566 / 568 SE / MG 569 typeBlue flame, oil burner control box (GULLIVER BLU BS 1/2/3/4)

Type Cell Pre Purge

Pre Igni-tion

Post Igni-tion

Safety Time

Manufac-turer ref. Ref

MG 569 replaced 568SE and 566SEIoniza-tion - - - - 300.1176 404020

BASE

1 2

Description Mark Ref

BASE 300 2256 for 505 /506 / 508 1 404061BASE 300 2307 for 525 2 404069

RV GAS CONTROL BOX05 type

Description Ref

Model 05125001 for EMAT (RS22) replaced by P16DIS 448002Model 0514 for SOLARONICS (SR21/31/41/42/62/82) 453005Model 05125004 for SOLARONICS/TRATHERM/RENDAMAX replaced model 05125002 and 05125003 453009

SATRONIC FUEL CONTROL BOXTF type

Pull-out equipment for oil burner control and security . Flame monitoring byphoto-resistant cell .

Type Pre Purge Pre IgnitionPost-

IgnitionSafety Tme Ref

Characteristic : 1 fi ring rate - Replaces TF 701 on 1 fi ring rate burners

TF 801 12" 12" 20" 10" 507005Characteristic : 2 fi ring rates same for 2 fi ring rates burners.

TF 802 12" 12" 20" 10" 507006

Control unit

CSB.255

Cont

rol u

nit

BO

TF type(continuation)

Type Pre Purge Pre IgnitionPost-

IgnitionSafety Tme Ref

Characteristic : 2 fi ring rates.

TF 804 12" 12" 3" - 5" 10" 507007Characteristic : With amplifi er of the detection circuit. Replaces without changing the base the TF 730 with an extension cable for the release button.

TF 830 12" 12" 18" 10" 507051Characteristic : . 220/240V -50Hz 5VA for ECOFLAM

TF 830.3 10" 10" 10" 10" 507064 TF 974 10" 10" 10" 10" 507016Characteristic : 2 fi ring rates.

TF 832 12" 12" 24" 10" 507053 TF 840 12" 12" 5" 10" 507054Characteristic : For burner with pre-heating 1 fi ring rate. Replaces without changing the base the TF 734 with an extension cable for the release button.

TF 834 12" 12" 18" 10" see507001

Characteristic : Security low voltage.

TF 834.3 12" 12" 20" 10" 507001Characteristic : Security low voltage no Post-ignition.

TF 834E.3 12" 12" - 10"see

507001

Characteristic : For burner with pre-heating 2 Firing rates.

TF 836 12" 12" 25" 10" 507050Characteristic : 1 or 2 fi ring rates.

TF 844 12" 12" 5" 10" 507057Characteristic :

TF 874 12" 12" 25" 10" 405002Note : TF700 boxes are replaced by Type 800 while adding an extension cable ref 507301 adjusting the reset switch level

TMO /TTO/MMO/DKW/DKO type

Pull-out equipment with flame monitoring by photo-resistant cell (on medium and high power burners). �Remote control release. �With or without recycling.

Type Pre PurgePre

IgnitionPost-

IgnitionSafety Time

Ref

Characteristic : - TMO 720-4-35 30" 30" 10" 5" 507020Characteristic : 2 fi ring rates TTO 810-35 30" 30" 20" 5" (1) TTO 836-35 30" 30" 20" 5" (2)Characteristic : - TTO 872 30" 30" 20" 5" (3)Characteristic : Use with preheater TTO 876 20" 20" 4" 5" (4)Characteristic : - MMO 872 10" 23,5" 8,5" 5" (3)Characteristic : preheater MMO 876 10" 23,5" 8,5" 5" (4)Characteristic : - DKO 970 - - - - 507009 DKO 972 - - - - 507012 DKO 974 - - - - 507014 DKO 976 - - - - 507015Characteristic : Replaces TTO 810-35/ TTO 872-MMO 872 DKW 972 + prolong. 10" 23,5" 8,5" 5" 507060Characteristic : Replaces TTO 836-35/ TTO 876-MMO 876 DKW 976 + prolong. 10" 23,5" 8,5" 5" 507062

TMO /TTO/MMO/DKW/DKO typeType Pre Purge

Pre Ignition

Post-Ignition

Safety Time

Ref

Characteristic : - DKW 972 10" 23,5" 8,5" 5" 507059 DKW 976 10" 23,5" 8,5" 5" 507061Characteristic : Special CUENOD - ELCO SH 113 - - - - 406013replacement KitER1 relay - - - - see

402023replacement KitER1H relay - - - - 402023Elcopen Analyser defect - - - - 402025NOTE : DXX type boxes, have a defect detection device. The reset switch blinks in a coding type, which indicates the defect location. A pocket size terminal type SATROPEN and PC module type SATROCOM are available on request.(1) Replaced by 507060 + (MZ cell ref 507101 if FZ cell stands or detec-tor IRD1010 depending on brand or cell UVD ref 507003).(2) Replaced by 507062 + (MZ r cell ef 507101 if FZ cell stands or detec-tor IRD1010 depending on brand or cell UVD ref 507003).(3) Replaced by 507060 + (detector IRD1010 depending on brand if IRD810 or 910 or 911 stands or cell UVD ref 507003).(4) Replaced by 507062 + (IRD1010 detector depending on brand if IRD810 or 910 or 911 stands or cell UVD ref 507003).

CELL

1Description Mark Ref

* FZ 711 S OERTLI and DE DIETRICH. special box Square plug - Red side detection 1 To consult

us* FZ 711 S white Cell - side and frontal detection for TTO 910 - TMO 720 2* It is necessary to change Cell and the box

SATRONIC FUEL CONTROL BOXCELL

1 2

3 4

Description Mark RefMZ 770 S Cell reduced, to be used only with boxes TF730-1/ TF730/ 733/734 & TF 821/822/830/834/840/740.1 - Supplied with FZ transformation taper

1 507101

MZ 770 long GIERSCH 4 507102MZ 770 S long BROTJE 3 507103Sheath and joint for MZ 770 BROTJE 2 430112

SH type

Type Pre Purge Pre IgnitionPost-

IgnitionSafety Time

Ref

Characteristic : Special CUENOD - ELCOSH 213 mod C1 - - - 5" 406019

2

Control unit

CSB.256

BO

Cont

rol u

nit

IRD INFRARED DETECTORFOR FUEL

1The monitoring function follows the infrared light vibration principle.

Description Mark Ref

MAN- BUDERUS IRD 1010 white axial shot - 507339BROTJE- BALTUR IRD 1010 blue side shot 2 430412KORTING IRD 1010 blue axial shot 1 507342NOTE : IRD 810/910/911 and 820/920 are replaced by type 1010 and 1020.you must know the brand of the device to find the right IRD detector.

BASE

1 2 3

Description Mark Ref

TF 804/836/844 2 507308TF 701/730/734/801/802/830/832/834/840 / 874TTO - MMO 1 507300TMO 720 3 507310S98 for DKW/DKG/DKO/DMG - 507004

ACCESSORIES

1Description Mark Ref

Extension to fi nd the same height with ref : TF 801 & 802 and ref : TF 701 1 507301Extension specifi c to BROTJE 1 430733BROTJE Joint Cell support - 430700BROTJE Glass Cell support - 430699

FR 870 MODEL

Application : � When it’s hard to reach heating equipment. � If burner fails, diffi cult to be reactivated. � Remote control reset is a necessary.

Description RefFR 870 compatible with ref : TF 800/ TFI 800 / MMI / MMG and TTO 876 507304

2

KBR and TF REPLACEMENT INDEXOLD BOX

Replaced by

ADAPTATION KITRefAdapter Extension Cell

with noneTF20/TF21A

TF 832Base to re-wire

507300

yes507301

Use Cell MZ507101

- -TF22KBR611KBR612

KBR612ATF 832

Base to re-wire

507300

yes507301

Use Cell MZ507101

- -KBR614AKBR617A/AC

TF 740 TF 840 - -Use

Cell MZ507101

- 507023

TF 701/TF714 TF 832 - - - - 507006TF 704 TF 834 - - - - 507007

TF 721 TF 832 - -Use

Cell MZ507101

- -

TF 821TF 822 TF 832 - -

Use Cell MZ507101

- -

TF 730 TF 832 - -Use

Cell MZ507101

- -

TF 734 TF 834 - -Use

Cell MZ507101

- -

TF 740 TF 840 - - Use Cell MZ507101 - -

TMO / TTO / MMO REPLACEMENT INDEXOLD BOX Replaced by Note

TTO 750-1 DKW972 Change Cell TTO 810 model 35 DKW972 Change CellTTO 836 model 35 DKW976 Change CellTTO 872 DKW972 Change CellTTO 876 DKW976 Change CellMMO 872 DKW972 Change CellMMO 876 DKW976 Change CellTMO 720

TMO 720.4 -TMO 720.2 TMO 721

SATRONIC GAS CONTROL BOX MMI/ MMG/ DKG/ DMG/ TTG/ SG type

Pull-out equipment with flame monitoring using ionization or UV cell (for medium and high power burners). Remote control release. With or without recycling.

Type Pre Purge Pre-

Ignition Post-

Ignition Safety Time

Ref

Characteristic : 2 Firing rates ionization replace box TTI 790-33

MMI 810-33 33" 3,5" 2,5" 1" 507037Characteristic : 2 Firing rates

MMI 810-35 30" 3" - 5" 507034Characteristic : 1 or 2 Firing rates detection by ionization or IRD

MMI 811-35 30" - - 5"replaced by 507063(except Guillot)

Characteristic : 1 Firing rate ionization with air fl ap control

MMI 812-33MMI 812-23

63" 3,5" 2,5" 1"replaced by 507033

Control unit

CSB.257

Cont

rol u

nit

BO

Type Pre Purge Pre-

Ignition Post-

Ignition Safety Time

Ref

Characteristic : 2 Firing rate ionization with air fl ap control

MMI 813.1 mod 23

63" 3,5" 2,5" 1" 507042

Characteristic : -

MMI 815 mod 5MMI 815 mod 10

- - - 5"or 10"replaced by507049

Characteristic : 1 Firing rate ionization with air fl ap control

MMI 962-23 63" 3,5“ 2,5" 1" 507033Characteristic : 2 Firing rates replaces without changingthe base the TTG 760-33 with an extension cable for the reset switch

MMG 810-33 30" - 3" 5" 507056Characteristic : 2 Firing rates

MMG 811-63 57" 3" 2,5" 3" 507058Characteristic : replaces box MMI 811 mod. 35

DMG971 - 24" - 3"507063

(except Guillot)

Characteristic : replaces box MMG 810-33

TTG 760-33 30" - 3" 3"replaced by507056

Characteristic : with control of parasite light and 2 Firing rates

TTG 760 FN 60" - 3" 3" replaced by507058

Characteristic : -

DKG 972 - - - 10“ 507049DKG 972 mod 21

- - - 21" 507065

Characteristic : Special CUENOD - ELCO

SG 113 - - - - 406009SG 513 - - - - 406020Kit replacement relay EM41

- - - - 402024

Elcopen Analy-ser defect

- - - - 402025

NOTE : DXX type boxes have a defect detection device. The reset switch blinks in a coding type, which indicates the defect location. A pocket size terminal type SATROPEN and a PC module type SATROCOM are availableon request.

TFI / DKG type

Pull-out equipment with flame monitoring using ionization or UV cell (for medium and high power burners). Remote control release. With or without recycling.

Type Pre Purge Pre

Ignition Post-

Ignition Safety Time

Ref

Characteristic : Special for REZNOR TFI 812-2 mod 10E

- - - 10"replaced by 507049

Characteristic : - DKG 972 - - - 10" 507049Characteristic : for atmospheric gas burner 2 fi ring ratesreplaces box TFI 712-10. For remote control reset use FR 870 ref 507304. TFI 812-2 maxi 120 Kw mod 10

-- 10" non 10" 507043Characteristic : for atmospheric gas burner 2 fi ring ratesreplaces box TFI 712 without changing the base ; with an exten-sion cable for reset switch. TFI 812-2 maxi 350 Kw mod 5

- 15" - 5" 507041

NOTE : DXX type boxes, have a defect detection device. The reset switch blinks in a coding type, which indicates the defect location. A pocket size terminal type SATROPEN and PC module type SATROCOM are availableon request

TTG type

Type Pre Purge Pre Igni-

tion Post-

Ignition Safety Time

Ref

Characteristic : replaced by MMG 810-33

TTG 760-33 30" - 3" 3"replaced by507056

Characteristic : with control of parasite light and 2 fi ring rates.

TTG 760 FN 60" - 3" 3" replaced by 507058

TMG typeProgrammable control box and ionization flame monitoring .Designed for gas burner models, the TMG can be used with a UV sensor on fuel-oil burner equipment.

Type Pre

Purge Pre

Ignition Post-

Ignition Safety Time

Ref

Characteristic : for fuel-oil and gas burner (2 Firing rates)TMG 740.3 model 32-32replaces TMG740.2 model 32-32

30" 3" - 2" 507032

TMG 740.3 model 43-35replaces TMG740.2 model 45-54

30" 3" 5" 5" 507039

FFW type to REPLACE FRA - FRU DANFOSSFor Atmospheric, ventilated, fuel or gas burner � For semi-automatic installation. � Flame formation delay : 1 second. � Flame safety time delay : 1 second.Control by Ionization or cell UVZ or infrared detector IRD 1020.

Description Ref

FFW 930 FUEL - GAS 507320

SATRONIC GAS CONTROL BOX CELL

Description Ref

UVZ 780 red spot - UV fl ame control cell for MMG 810 and 811 507111UVZ 780 white spot - UV fl ame control cell for TMG 740-2 and 740-3 +TTG 507112

UV DETECTION LAMP

Description Ref

SYLVANIA UV detection Lamp P607.08 Ø 22mm - 4 pin plugs 502312

Control unit

CSB.258

BO

Cont

rol u

nit

IRD INFRARED DETECTOR

For Gas The monitoring function follows the infrared light vibration principle

Description RefOLYMP -HG-HLG IRD 1020 BLEUE side shot ( IRD 920 replacement with IRD 1020 needs a M93 support) 507341

NOTE : IRD 810/910/911 and 820/920 are replaced by type 1010 and 1020. you must know the brand of the device to find the right IRD detector.

ACCESSORIES

1

Description Mark Ref

M93 Magnetic support for IRD 1020 - 507350ZT 870 Transformer 1 805913AZ 5 Burner 2 708790

BASE

1The extension for TFI is used to adjust the height on the old boxes (The new ones are lower)

Description Mark Ref

TMG 740 1 507307TTG - FN - MMI 811/ 812 - MMG 811/ 812 - TTG - TTI MMI 810 - MMG 810- TTI 790 - TF 804 /836/844 - 507308

TFI/TMG740 3 507300DKG/DMG/DKO - 507004Extension TFI 812 2 507301Extension specifi c BROTJE - 430733

IBR - BR - GBR - TTG TFI - MMI - TMA - TMG TTI REPLACEMENT INDEX

OLD BOX Kit or replacement box RefReplaced by Adapter

IBR 661 TME 780 (on request)

Base to re-wire (esti-mat request)

cell to change (UVZE est req.)

-

BR 661 TMG 740-3 (Ref 507032)

Base to re-wire (ref 507302) cell to

change (ref 507112)-

GBR 681 or GBR 681/74

MMI 810.33 (Ref 507037)

Base to re-wire (Ref 507308) -

TTG 760.33 MMG 810 mod 33

Terminal 1 and 9 rewire on base 507056

TTG 760 FN MMG 811 mod 63 - 507058

TFI 712F-1 /TFI 712FTFI 812-1 mod 5 TFI 812-2 mod 5 Provide switch exten-

tion 507301 507041TFI 712-1 /TFI 712TFI 812-1 mod 10

TFI 812-2 mod 10

Provide switch exten-tion 507301 507043

TFI 812-2 mod 10E DKG 972 - 507049MMI 810 mod 32 MMI 810.33 - 507037

MMI 811 mod 35 DMG 971 Caution: pressure

switch wiringto terminals 4 and 7

507063(except Guillot)

2

2 3

IBR - BR - GBR - TTG TFI - MMI - TMA - TMG TTI REPLACEMENT INDEX (continuation)

OLD BOX Kit or replacement box RefReplaced by Adapter

MMI 812 mod 23 MMI 812 mod 33MMI 812-1 mod 23MMI 812 mod 63

MMI 962-1 mod23 - 507033

MMI 815 mod 5MMI 815 mod 10 DKG 972 - 507049TMG 720 /TMG 740 TMG 740-1

TMG 740-3 mod 32-32 - 507032

TMG 740-2 mod 45-54

TMG 740-3 mod 43-35 - 507039

TTI 790-33 MMI 810-33 terminal 1 & 9 rewire on Base 507037

SIT GAS CONTROL BOX503 and 537 type

Type Pre Purge Pre

Ignition Post-

Ignition Safety Time Ref

Characteristic : RIELLO - SEET0.503.902 - - - - 503008Characteristic : WOLF - DE DIETRICH0.503.501 - - - - 503009Characteristic : BALTUR - ARIANE - SIME - HERMANN - UNICAL 0.537.301 type DMT 1,5" - - 10" 431015Characteristic : BENESSERE - PRONTACQUE SALVASPAZIO BERETTA - RIELLO0.537.002 type DMT 1,5" - - 7,5“ 404026Characteristic : DOMUSA (CGAS 000130)0.537.201 - - - - 503010

Characteristic : -0.537.501 - - - - 503011

577 typeType Pre Purge

Pre Ignition

Post-Ignition

Safety Time Ref

Characteristic : GAZ INDUSTRIE

0.577.503 30" - - 30" 471003Characteristic : GAZ INDUSTRIE - BIASI

0.577.504 5" - - 30" 503001Characteristic : ACV

0.577.009 - - - 5" 503002Characteristic : EMAT

0.577.308 - - - 5" 503003Characteristic : SAUNIER - UNICAL

0.577.311 1,5" - - 10" 503004Characteristic : OERTLI - DE DIETRICH

0.577.211 - - - 55" 503005Characteristic : DE DIETRICH

0;577.705 - - - 10" 503006Characteristic : SAUNIER

0.577.304 1,5" - - 10" 503007Characteristic : DE DIETRICH

0.577.702 - - - - 5030120.577.701 - - - - 503013

Control unit

CSB.259

Cont

rol u

nit

BO

STANDARD INSULATION TRANSFORMERFEATURES :

� IN : 220- 240V OUT : 260-280V � 50 -60 HZ � Power : 20VA � Connection : Terminal faston 6,35 mm

Sizes Fixation Entraxe

L l H F E G HT

64 54 52 72 44 - -

Description Ref

INSULATION TRANSFORMER 805961NOTE : To increase and regulate the ionization sensor signal

USE: To increase and regulate the ionization sensor signal in control box installa-tions which are not earthed neutral wired.

APPLICATION :The ionization sensor wire comes from the control box, goes through the isola-tion transformer secondary and returns to the sensor. The isolation transformer primary is supplied through the same supply as the control box..

Note: be careful this transformer is a primary and secondary transformer. The fact of using the primary and the secondary is harmful.

MICROAMMETER type MAP portable

USE � The micro Ammeter MAP measures the very low intensity of the ionization and UV cell current for fuel blue fl ame burners with ionization sensor. � Checks functionning state of fl ame detection : �By ionization (burner with electrode) �By UV cell � Measurement -10µA / 0 / +10µA, -50µA/ 0 /-50µA ou -100µA / 0 / -100µA (according to the selected model). Its zero allows measurement even if the wires are commutated.

A micro Ammeter is installed in series (on the same line as the probe or the cell to be measured).

Description Ref

MAP -10/0/+10µA Size : L 140 x H 85 x E 55 mm 906567MAP -50/0/+50µA Size : L 140 x H 85 x E 45 mm 906565MAP -100/0/+100µA Size : L 140 x H 85 x E 55 mm 906562

IONIZATION CURRENT MONITORING - RC MODULE

Improves the value of the ionization current when, in the electric feeder systems, the zero lead has a weak potential difference with the mass of the burner. Bipolar connection between the zero lead and the mass of the burner. � Size : L 25 x P10 x H 18m

Description Ref

Module RC model ARC4 66890660 502316

VARIOUS AMP and MULTICONTACT CONNECTOR

12

3 4

Description Mark Ref

With 3 wires cable 0,40 m for RAPA valve, SUNTEC, DANFOSS Electrovalve 3 803030

With 3 wires cable 0,40 m for RAPA valve, SUNTEC, DANFOSS Electrovalve 3 803034

With 3 wires cable 0,80 m for RAPA valve, SUNTEC, DANFOSS Electrovalve 3 803029

With 3 wires cable for ELCO, CUENOD ignition transformer 3 803031

Straight male 3 pin plugs 4 803032Straight female 3 pin plugs 1 803033Cable with connector for preheater 2 see 803036

Angle connector Female 3 pin plugs 1 470003

DOUBLE CONNECTOR

Description Ref

Double contact connector WEISHAUPT - connector DIN 407100

x 6

x 6

x 6

x 1

Control unit

CSB.260

BO

Cont

rol u

nit

DOUBLE CONNECTORWIELAND type1

2Many burners are connected with a 6 male poles plug. The same piece can be connected between different installation equipment such as the circulator, and the regulation and control board. For the 6 poles plug, we choose the locking type. Anyway, the 2 parts stay pluggable, with or without a locking system.

Description Mark Ref

Male 3 poles 2 803050Female 3 poles 2 803051Male 4 poles - 803040Female 4 poles - 803041Male 5 poles - 803010Female 5 poles - 803011Male 6 poles 1 803001Female 6 poles 1 803002Male 7 poles - 803020Female 7 poles - 803021

PRE-WIRED BASEBROTJE

Type Characteristic Manufacturer ref Ref

0.501 M for ESB 24-28 521185 4303740.501 M for ESB 32-41 521192 -0.30U for EB-U 17-25 533577 4303680.32U Blue Jet

533577430368

0.32.1 - 0.31.1 - 0.30.1 4303680.501 M for DU 19 539098 -0.41.1 - 0.42 536004 4307150.112 without starter Base wired with

preheater530309 -

0.112 without starter 530316 -

CHAPPEE

1

Type Manufacturer ref Mark Ref

Characteristic : Base wired with preheater

TIGRA CF 500 58539863 1 401031TIGRA CF 500 58539864 2 401032Characteristic : Base wired with preheaterLANDIS type

TIGRA CF 500 58539910 1 401042

2

CUENOD

Type Manufacturer ref Ref

Characteristic : -

NC 4 gas - NC 6 gas - NC 9 gas grey cap 13010521 406008Characteristic : Base wired with preheater

NC 4 - NC 6 - NC 9 grey cap 13010979 406011

DE DIETRICH

1

Type Manufacturer ref Mark Ref

Characteristic : Base wired without preheater

MX10 -M1.4S - M1.5S - M1.6S M1.5CS - M1.6CS - M14S M18S M19S - M18CS - M19CS - M10CS

9790-7598 1 405700

Characteristic : Base wired without preheater

M104 9795-5503 1 439118M10R -M16RS -M17RS -M16RCS M1.4RCS 9790-7599 405701

Characteristic : Base wired with preheater

M1.3RS -M1.4RS - M1.3RCS M1.4RCS M10RD - M10RCS M10RCS 9790-7597 2 405702

M104 9795-5504 2 439119

ELCO

TypeManufacturer

refRef

Characteristic : Only SIP66 Base not wired, used to repair SIP 45/46/63/64/65 pre-wired base

- CAS 106295 803061Characteristic : SIP45 Base wired without preheater

EL 01A2H /A3H/ A5H CAS 106244 402101Characteristic : Base wired without preheater

EL 03B20V/30V - EL 1B3/B5/B8 - EL02B16 CAS 106684 402102Characteristic : SIP45 Base wired without preheater

EL 03.20H / 20V/ 30H/ 30VEL 01 A3/ A5/ A8 - EL 02.9/02.15 CAS 106156 402100

Characteristic : SIP65 Base wired without preheater

EL 03.20 1D/1DO - EL03.30 1D/1DOEL02.9 1D/1DO - EL02.15 1D/1DO SIP 065 402104

2

Control unit

CSB.261

Cont

rol u

nit

BO

IDEAL STANDARD

TypeManufacturer

refRef

Characteristic : Base wired with preheaterHELIS 500 / HELIS MI500 58539863 401031Characteristic : Base wired without preheaterHELIS 500 / HELIS MI500 58539864 401032Characteristic : Base wired with preheater LANDIS typeHELIS 500 / HELIS M500 58539910 401042

OERTLI

1 2

TypeManufacturer

refMark Ref

Characteristic : Base wired without preheaterOES 310 LE - OES 130 LE 102102 1 405700Characteristic : Base wired with preheater OES 310 LEV 101754 2 405701OES 130 LEV 102104 2 405702

Control unit

CSB.262

BO

Cont

rol u

nit

IGNITION SPARK DETECTORDEFINITION :Linked to a flame detector circuit that uses ionization electrode, the system detects a flame signaling a spark.It replaces the UV cell for ignition spark detection when the use is compromized.

IGNITION SPARK DETECTOR model DA51 ECEE ref : diff 501660

IGNITION SPARK DETECTOR model QRE1 Landis and Gyr ref : diff 502315ormodel RT1 Brahma ref : diff 504220

Note : In both cases, the high frequency wave created by the ignition spark, provides a necessary contact when ionization sensor current goes through. The detection avoids trouble in case of short-circuit electrode.

INFORMATION

On fuel or gas burners, the modernization and miniaturization of control boxes allow rapid and safe maintenance, through the use of microprocessors.

On the new generation relays, breakdowns indeed are automatically detected by electronics, thus enabling quick diagnosis and reducing attendance.

LMO (replacing soon LOA relays) and LMG (replacing soon LGB relays) have a very fi ne process. Through a blinking light code, they show the cause of the failure

Failure code tables

LMOBlinking code CauseBlinking 2x

••no fl ame at the end of “TSA” � Defective or clogged fuel valves � Defective or clogged cell � Bad burner adjustment or no fuel � Defective ignition system

Blinking 4x

••••parasite light when burner starts

Blinking 7x

•••••••fl ame disappearing too often � Defective or clogged fuel valves � Defective or clogged cell � Bad burner adjustment

Blinking 8x

••••••••Time control of the fuel preheater

Blinking 10x

••••••••••Bad wiring, internal defect or output con-

tacts

LMGBlinking code Cause

Blinking 2 x ••

no fl ame at the end of "TSA" � Defective or clogged fuel valves � Defective or clogged electrode/cell � Bad burner adjustment

Blinking 3x •••

Pressure switch does not close� Defective "LP"� "LP" not adjusted � the fan does not function

Blinking 4x ••••

Pressure switch does not open; parasite light when burner starts� Defective "LP" � "LP" not adjusted

Blinking 5x ••••• parasite light during preventilation or internal defect

Blinking 7x •••••••

fl ame stops during the operation � Bad burner adjustment � Defective or clogged fuel valves� Short circuit between ionization electrode and earth

Blinking 18x ••••••••••••••••••

the pressure switch opens during preventilation or operation � "LP" badly adjusted� fl ame stops for the 4th time

Blinking 19x •••••••••••••••••••

defective ouptput contacts� Bad wiring

� Or another power supply at the output Blinking 20x ••••••••••••••••••••

internal defect