36
Control and Measure Instruments innovation > technology > future

Control and Measure Instruments - dosya.ertek.comdosya.ertek.com/pdf/Kataloglar/Seko/Seko Kontrol 500-502 - 40-42... · Kontrol 500-502 Single and twin-parameter control instruments

Embed Size (px)

Citation preview

Controland MeasureInstruments

innovation > technology > future

seko > water & industry > control and measuring instruments02

Kontrol 500-502 Single and twin-parametercontrol instruments

l pH / ORPl Conductivityl Dissolved Oxygenl Chlorinel Chlorine Dioxidel Hydrogen Peroxidel Ozonel Peracetic Acidl Turbidityl Suspended solids

Parameters

l Waste Waterl Drinking Waterl Cooling Towersl Boilerl Legionella disinfectionl Reverse Osmosisl Sludgel Crate Washl Galvanic Processl Dioxide Stationl CIPl Irrigationl Swimming Pooll Fish Farmingl Sea waterl Dairy

Applications

FeaturesGraphic display and Keypad128 by 64 pixel resolutionmonochrome display with graphicicons to show digital output status,Data logging, washing cycle, alarms.Simultaneous flashing values for themeasurement (numeric + bargraph)and temperature readings.Analogue scrolling output values.Five control keys for instrumentcalibration and configuration.

Enclosure Boxand Power SupplyWall mounting ABS plastic materialIP65 (144x144)Panel mounting IP54 (96x96)Universal Power Supply100÷240 Vac 50/60 Hz

Manual controlsThe user-friendly programming stepmenu makes starting up and checkingthe control and dosing system easy.

Kont

rol 5

00-5

02

The Kontrol 500-series are advanced controllers designed for high-end applications. The units feature independentproportional PID-enabled control outputs, RS 485 serial port with MODBUS protocol, USB port on request, probe qualitychecking, a variety of outputs and full data logging capability. The user has full programming authority.

innovation > technology > future 03

Data loggingInternal Flash Memory with recordsinterval from 1 to 99 min. (near to16000 records)Visualization key for stored data intabular and graphic form. Type: Circular (F.I.F.O.) or Filling.

RS485 Serial portTo set-up and to acquire/capture realtime data or to download stored dataon PC or laptop (CommunicationSoftware Master Controller NETrequired).MODBUS RTU communication protocol

USB portTo download recorded data onremovable memory Usb Pen Drive(upon request).

Measure InputHigh measuring resolution withprobe quality control.Modular measuring systemChlorine measure for sea waterapplication.

Digital InputDedicated to disable all controlleroutput functions.

Current outputs4÷20mA Galvanic isolation Two independent programmableOutput Measures with PID routineregulation.

Relay OutputsFour independent relais, two set points,one alarm remote output, onbackwashing probe output.On/OFF, Timed routine function setting.

Measure range

pH 0 ÷14,00 pHORP ± 1500 mV

Conductivity 0÷20 /200 /2.000 /20.000 /200.000 μSInductive Conductivity 0÷10.000 /10.000 /100.000 /999.999 μSDissolved Oxygen 0÷20,0 ppm or mg/l - 0÷200% SATChlorine and Chlo. Dioxide 0÷0,50/1,00 /2,00 /5,00 /10,0 /20,0 /200,0 ppmHydrogen Peroxide 0÷500 /1000 /2000 /10.000 /100.000 ppmOzone (03) 0÷0,5 /2,00 /5,00 /10,00 ppmPeracetic Acid 0÷500 /2000 /10.000 /20.000 ppmTurbidity 0,00÷1,00 /10,0 /100 NTU/FTUSuspended Solids Turbidity 0,0÷4,00 /40,0 /400 /4.000 NTU/FTU - 0÷30 gr/lTemperature with PT100/PT1000 0÷100°C (32÷212 °F)

Product lineCode Model Description

Code Description

K500PR Kontrol PR 500

K500CD Kontrol CD 500

K500ID Kontrol ID 500

K500OX Kontrol OX 500

K500CL Kontrol CL 500

K500T1 Kontrol TB 500

for pH or ORP values

for Conductivity values

for Inductive Conductivity values

for Dissolved Oxygen values

for Chlorine values

for Turbidity values

K500T2 Kontrol TS 500 for Suspended Solid Turbidity values

K502PR Kontrol PR-PR 502

K502PD Kontrol PR-CD 502

K502PO Kontrol PR-OX 502

K502PC Kontrol PR-CL 502

K502CC Kontrol CD-CL 502

K502TO Kontrol TB-OX 502

for pH/ORP - pH/ORP values

for pH/ORP - Conductivity values

for pH/ORP - Dissolved Oxyge values

for pH/ORP - Chlorine values

for Conductivity - Chlorine values

for Turbidity - Dissolved Oxygen values

K502TX Kontrol TS-OX 502 for Suspended Solids Turbidity - Dissolved Oxygen values

K502PI Kontrol PR-ID 502 for pH/ORP - Inductive Conductivity values

Kontrol 500 Single parameter

Product line Kontrol 502 Double parameters

The unit’s Software enables the following measures: H2O2 - O3 - ClO2 - C2H4O3

l pH / ORPl Conductivityl Dissolved Oxygenl Chlorinel Chlorine Dioxidel Hydrogen Peroxidel Ozonel Peracetic Acidl Turbidity

Parameters

l Waste Waterl Drinking Waterl Cooling Towersl Boilerl Legionella disinfectionl Reverse Osmosisl Sludgel Crate Washl Galvanic Processl Dioxide Stationl CIPl Irrigationl Swimming Pooll Fish Farmingl Sea waterl Dairy

Applications

FeaturesGraphic display and Keypad128 by 64 pixel resolutionmonochrome display with graphicicons to show digital output status,Data logging, washing cycle, alarms.

Simultaneous flashing values for themeasurement (numeric + bargraph)and temperature readings.

Four control keys for instrumentcalibration and configuration.

Enclosure Boxand Power SupplyWall mounting ABS plastic materialIP65 (144x144)

Panel mounting IP54 (96x96)

Universal Power Supply100>240 Vac 50/60 Hz

Kont

rol 2

00

Kontrol 200Single-parameter controlinstrumentThe Kontrol 200-series are advanced controllers designedfor simpler high-end applications. The units feature anindependent proportional control output, probe qualitychecking and a variety of outputs . The user has fullprogramming authority.

seko > water & industry > control and measuring instruments04

K200TB Kontrol TB 200 for Turbidity values

Manual controlsThe user-friendly programming stepmenu makes starting up and checkingthe control and dosing system easy.

Measure InputHigh measuring resolution with probequality control.

A modular measuring system

Chlorine measure in sea waterapplication.

Digital InputDedicated to disable all controlleroutput functions

Current outputs4÷20mA Galvanic isolation One independent programmableOutput Measures.

Relay OutputsFour independent relais, two set points,one alarm remote output, onbackwashing probe output.

On/OFF, Timed routine function setting.

Measure range

pH 0 ÷14,00 pHORP ± 1500 mV

Conductivity 0÷20 /200 /2.000 /20.000 /200.000 μSInductive Conductivity 0÷10.000 /10.000 /100.000 /999.999 μSDissolved Oxygen 0÷20,0 ppm or mg/l - 0÷200% SAT (*)

Chlorine and Chlo. Dioxide 0÷0,50/1,00 /2,00 /5,00 /10,0 /20,0 /200,0 ppmHydrogen Peroxide 0÷500 /1000 /2000 /10.000 /100.000 ppmOzone (03) 0÷0,5 /2,00 /5,00 /10,00 ppmPeracetic Acid 0÷500 /2000 /10.000 /20.000 ppmTurbidity 0,00÷40 NTU/FTU (**)

Temperature with PT100/PT1000 0÷100°C (32÷212 °F)

Code Description

Product lineCode Model Description

K200PR Kontrol PR 200

K200CD Kontrol CD 200

K200ID Kontrol ID 200

K200OX Kontrol OX 200

K200CL Kontrol CL 200

for pH or ORP values

for Conductivity values

for Inductive Conductivity values

for Dissolved Oxygen values

for Chlorine values

Kontrol 200 Single parameter

By software it is available the following measures:H2O2 - O3 - ClO2 - C2H4O3

(*): Dissolved Oxygen probe Oxysens ® only(**): Turbidimetric probe 462/SWP only

innovation > technology > future 05

Kontrol 800Multi-parameter controlinstrumentThe Kontrol 800 is a dedicated multi-parameter controllerfor complex applications that require a number ofchemical parameters to be checked at the same time. Theunit features independent proportional control outputmeasures, two programmable frequency outputs, RS 485serial port with MODBUS protocol, three relais outputs,probe quality checking and Data logging capability.

l pH / ORPl Conductivityl Chlorinel Chlorine Dioxide

Parameters

l Waste Waterl Drinking Waterl Cooling Towersl Boilerl Legionella disinfectionl Reverse Osmosisl Sludgel Crate Washl Galvanic Processl Dioxide Stationl CIPl Irrigationl Swimming Pooll Fish Farmingl Sea waterl Dairy

Applications

FeaturesGraphic display and KeypadSimultaneous value of the measure,Temperature and Relay status.

4-line, 20-character AlphanumericDisplay.

Seven control keys for instrumentcalibration and configuration.

Enclosure Boxand Power SupplyWall mounting ABSplastic material IP65.

Universal Power Supply100÷240 Vac 50/60 Hz

Manual controlsThe user-friendly programming stepmenu makes starting up and checkingthe control and dosing system easy.

Data loggingInternal Flash memory to load recordmeasures values.

Type: Circular (F.I.F.O.) or Filling.

Kont

rol 8

00

seko > water & industry > control and measuring instruments06

Measure range

pH 0÷14,00 pHORP ± 200 mV

Conductivity 1÷200/10÷2000/100÷20.000 μSChlorine (Amperometric Cell)

(Potentiostatic Cell)

0÷5,00 ppm (*)

Chlorine and Chlo. Dioxide 0÷0,50 /1,00 /2,00 /5,00 /10,0 /20,0 /200,0 ppm

with PT100/PT1000 0÷100°C (32÷212 °F)

Product lineCode Model Description

Code Description

K800L01 Kontrol CL 800 for Amperometric Chlorine values

K800L06 Kontrol CLP 800 for Free and Total Potentiostatic Chlorine values

Kontrol 800 Single parameter

RS485 Serial portFor set-up and real-time dataacquisition from remote or for storeddata download on PC or laptop(Communication software Sekonetrequired).

MODBUS RTU communication protocol.

Measure InputHigh measuring resolution with probequality control.

Modular measuring system.

Chlorine measure in sea waterapplication.

Digital InputDouble channel, Voltage Input andReed level input to disable all functioncontroller output.

Current outputs4÷20mA Galvanic isolation Two (2) programmable OutputMeasure.

Frequency Outputs1÷120 Pulse/Minutes open collectorIsolation channel.

Two (2) programmable OutputMeasure.

Relay OutputsThree (3) independent relais,Three (3) set point measure with powercontact.

One Alarm remote dry contact One Set point Measure dry contact.

On/OFF, Timed, Proportional routinefunction setting.

K800L02 Kontrol PR 800

K800L03 Kontrol PC 800

K800L04 Kontrol PRC 800

for pH/ORP - pH/ORP values

for pH/Amperometric Chlorine values

for pH/ORP - Amperometric Chlorine values

K800L05 Kontrol PR+EC 800 for pH/ORP - Conductivity values

K800L07 Kontrol PCP 800 for pH + Potentiostatic Chlorine values

K800L08 Kontrol PRCP 800 for pH /ORP + Potentiostatic Chlorine values

K800L09 Kontrol PRCP+CA 800 for pH/ORP + Pot. and Amperometric Chlorine values

Product line Kontrol 800 Double parameters

Temperature

(*): Amperometric Chlorine CU+PT

innovation > technology > future 07

Phot

omet

er S

yste

m

seko > water & industry > control and measuring instruments08

Multi parameterphotometer instrument

The Seko Photometer System is a DPD reference point for Chlorine control. The combination of water sampling and reagents ensuremaximum measurement precision. The unit itself is a compact miniature analysis laboratory dedicated to Chlorine measurement.

Photometer System

l pH / ORPl Free and Total Chlorinel Combined Chlorine by software

Parameters

l Waste Waterl Drinking Waterl Boilerl Legionella disinfectionl Crate Washl Dioxide Stationl Irrigationl Swimming Pooll Sea water

Applications

FeaturesThe unit has the following innovative features:

– New hydraulic device with water drain dedicated tochemical reagents used for chlorine measure. Therefore itallows to reduce the water amount used for chlorinemeasure. The water dedicated to pH and Redox probes itmay be to restored in the compensating basin, whileonly the water with chemical DPD reagent will bedischarged in special tank to observes the local law.

– Fast installation thanks to quick coupling for Inlet andOutlet water.

– Optical unit assure a High accuracy Chlorine measurewith a 520 nm sensor and LED light device.

Moreover:

– The Peristaltic pump with 4 mechanical support assurechemical reagent saving.

– Reagent level controlled by level probes.– The chemical powder to dilute before the use is a good

solution safety to keep it ready in every place.

Graphic display and KeypadLCD STN 340x128 backlighted.

Visualisation of: measurements (simultaneous up to 4values + trend line), digital outputs condition, storagecondition, malfunctions.

Using keypad with 4 embossed keys.

Photometer Entry levelPhotometer System

Measure range

pH 0÷14,00 pH

ORP ± 1500 mV

Chlorine (Photometric chamber) 0÷5,00 ppm (*)

Temperature with PT100/PT1000 0÷100°C (32÷212 °F)

Product lineCode Model Description

Code Description

SPT2CL Photometer

SPT2CT Photometer

Free Chlorine

Total Chlorine

Photometer System Single parameter

SPT3CL(*) Photometer

SPT4CL Photometer

SPT5CL Photometer

Free Chlorine and pH

Free Chlorine, pH and Redox

Free, Total and Combined Chlorine, pH, Redox

Product line Photometer System Multi parameters

Internal data logger4 Mbit flash memory equal to 16000records

Recording interval00:00 to 99:99 min

Type: circular / fill

Display: table / graph(1 for each parameter).

Analogue outputs1 for each measured parameter(excluding comb. chlorine)

Type: 0.00 / 4.00 to 20.00 mAGalvanically isolated

Programming limit:lower / upper / reverse

Maximum load: 500 Ohms - Alarmoutput NAMUR compliant 2.4 mA (with4÷20 mA range)

PID control function can be activatedon the pH output

Set point relay outputsTwo (2) for Primary measure + for pHmeasurement (only mod. 4001-3)

Programming for Hysteresis, workingtime and Daily hourly activation notsubject to the measured value:- ON - OFF- 00.00 to 05:00 ppm Cl 2- 00:00 to 14.00 pH

Working time: 000 to 999 sec.

Relays 5A resistiveload up to 230 Vac

Alarm Relay OutputTwo (2) for Primary measure+ Two (2) for pH measurement(only mod. 4001-3)

Programming for Hysteresis, workingtime and Daily hourly activation notsubject to the measured value:- ON - OFF- 00.00 to 05:00 ppm Cl 2- 00:00 to 14.00 pH

Working time: 000 to 999 sec.

Relays 3A resistive load up to 230Vac

(*): DPD Method

(*): Sea water application on demand code SPT3CLMW0001

SPL3CL Photometer Free Chlorine, pH and Redox

Product line Photometer Entry level Multi parameters

innovation > technology > future 09

seko > water & industry > control and measuring instruments10

l pH / ORPl Conductivityl Chlorinel Chlorine Dioxidel Flow Rate

Parameters

l Waste Waterl Drinking Waterl Cooling Towersl Boilerl Legionella disinfectionl Reverse Osmosisl Crate Washl Galvanic Processl Dioxide Stationl CIPl Irrigationl Swimming Pooll Sea water

Applications

FeaturesGraphic display and KeypadSimultaneous value of the measure,Temperature and Relay status.

2-line, 16 character AplhanumericDisplay.

Four control keys for instrumentcalibration and configuration.

Enclosure Boxand Power SupplyFour (4) mechanical box:Wall mounting PP (IP65)

Panel mouting:96x96 IP65 Front panel48x96 IP40Din-Rail (6 modules) IP40

Universal Power Supply100÷240 Vac 50/60 Hz and 24Vac/dc

Kont

rol 4

0-42

Kontrol 40-42 Single and multiple-parametercontrol instruments

The Kontrol 40 and 42 are single and multiple-parameter controllers respectively. These very user-friendly systemscombine advanced performance and simple design. Single-parameter units are available in four different casings,ensuring perfect fit at the right price.

innovation > technology > future 11

Measure range

pH 0÷14,00 pH

ORP ± 1500 mV

Conductivity 1÷200/10÷2000/100÷20000/200÷50000 μS

Chlorine (Amperometric Cell)

(Potentiostatic Cell)

0÷5,00 ppm

Chlorine and Chlo. Dioxide 0÷0,50 /1,00 /2,00 /5,00 /10,0 /20,0 /200,0 ppm

*setting by software following unit measures: l/s, l/h, m³/h, GPM.

Flow Rate 99 999,99 Liters/second

with PT100 0÷100°C (32÷212 °F)

Product lineCode Model Description

Code Description

SPR040 Kontrol 40 for pH/ORP values

SCD040 Kontrol 40 for Conductivity value

SCL040 Kontrol 40 for Potentiostatic Chlorine value

SFX040 Kontrol 40 for Flow Rate value

Kontrol 40 Single parameter

Manual controlsThe user-friendly programming stepmenu makes starting up and checkingthe control and dosing system easy.

Measure InputHigh measuring resolution with probequality control.

Modular measuring system

Chlorine measure in sea waterapplication

Digital InputVoltage Input to disable all functioncontroller output.

Current outputs4÷20mA Galvanic isolation One(1) programmable measurementoutput.

Relay OutputsTwo (2) independent function, two Setpoint Measure, dry contact.

Software-set alarm functions.

Routine function settings : ON/OFF,Timed or proportional

K042PR Kontrol 42

K042PD Kontrol 42

K042PC Kontrol 42

for pH/ORP and pH/ORP values

for pH/ORP and Conductivity values

for pH/ORP and Chlorine values

K042CF Kontrol 42 for Chlorine and Flow Rate values

K042PF Kontrol 42 for pH/ORP and Flow Rate values

K042DF Kontrol 42 for Conductivity and Flow Rate values

Product line Kontrol 42 Double parameters

Temperature

seko > water & industry > control and measuring instruments12

l pH / ORPl Conductivity

Parameters

l Waste Waterl Drinking Waterl Cooling Towersl Boilerl Reverse Osmosisl Galvanic Processl Irrigationl Swimming Pool

Applications

FeaturesGraphic display and Keypad2-line, 16 character AplhanumericDisplay.

Four control keys for instrumentcalibration and configuration.

Enclosure Boxand Power SupplyFour (4) mechanical box:

Wall mounting PP (IP65)

Panel mouting:

96x96 IP65 Front panel

48x96 IP40

Din-Rail (6 modules) IP40

Universal Power Supply100÷240 Vac 50/60 Hz

Kont

rol 2

0 - 2

2

Kontrol 20-22 Single or multi-parametercontrol instruments

The Kontrol 20 and 22 are simplified, bare-bones single and multiple-parameter controllers respectively. Thesetrustworthy systems combine reliable high-end performance and simple design. Single-parameter units are availablein four different casings, ensuring perfect fit at the right price.

innovation > technology > future 13

Measure range

pH 0÷14,00 pH

ORP ± 1500 mV

Conductivity 1÷200/10÷2000/100÷20000 μS

with PT100 0÷100°C (32÷212 °F)

Product lineCode Model Description

Code Description

SPR020 Kontrol 20 for pH/Redox values

SCD020 Kontrol 20 for Conductivity value

Kontrol 20 Single parameter

Measure InputHigh measuring resolution with probequality control.

Digital InputVoltage Input to disable all functioncontroller output.

Current outputs 4÷20mA One (1) programmable measure output.

Relay OutputsTwo (2) independet functions, Set PointMeasure, dry contact.

Software to set alarm functions.

ON/OFF routine function settings.

K022PR Kontrol 22 for pH and Redox values

Product line Kontrol 22 Double parameters

Temperature

seko > water & industry > control and measuring instruments14

pH/Redox Probes

Features:· Low maintenance sealed unit· Gel filled reference cell· BNC connection with Boot plastic Cover· Cable length 6 or 1,5 meter· Pellon Diaphragm high accuracy

Features:· Low maintenance sealed unit· Gel filled reference cell· S7 connection· Pellon Diaphragm high accuracy

Features:· Low maintenance sealed unit· Gel filled reference cell· S8 connection with PG 13,5 mm· Glass Body· Diaphragm open hole

Field Application:

· General laboratory

· Drinking Water

· Swimming pools

· Water monitoringand control plan

SPH-1 / SRH-1Field Application:

· Waste water

· Drinking Water

· Cooling Towers

· Irrigation

SPH-2Field Application:

· Waste water

· Drinking Water

· Cooling Towers

· Legionella disinfection

· Galvanic Process

SPH-3 WWSRH-3 PT

Features:· Low maintenance sealed unit· Gel filled reference cell· S8 connection with PG 13,5 mm· Glass Body for High TemperatureEnviromental

· Diaphragm 2 Sigle pore

Field Application:

· Waste water

· Drinking Water

· Reverse Osmosis

· Cleaning in place (CIP)

· Galvanic Process

SPH-4 HP

Features:· Low maintenance sealed unit· Gel filled reference cell· S8 connection with PG 13,5 mm· Glass Body for High Pressure Enviromental· Three ceramic diaphragm type

Field Application:

· Ammonia application

· Chromium plating

· Reverse Osmosis

· Bisulphite application

· Galvanic Process

SPH-4 HTSRH-4 HT-PT

Field Application:

· Highly acidic solutions

· Chromium plating

· Reverse Osmosis

· Bisulphite application

· Galvanic Process

SPH-4 LC

Features:· Low maintenance sealed unit· Gel filled reference cell by External Refill· S7 connection with PG 13,5 mm plastic nut· Glass Body for low pressure Enviromental· Highly acidic solutions· One Sleeve diaphragm type

innovation > technology > future 15

SPH-1 1.5M Code 9900105001

SPH-1 6M

SPH-2

SPH-3 WW

SPH-4 HP

SPH-4 HT

SPH-4 LC

Mea

sure

men

tra

nge

Min

.co

nduc

tivi

ty

Tem

pera

ture

rang

e

Pres

sure

rang

e

Body

mat

eria

l

Mem

bran

em

ater

ial

Refe

renc

eel

ectr

olyt

e

Dia

phra

gmty

pe

Elec

tric

alco

nnec

tion

Mec

hani

cal

mou

ntin

g

p H

Code 9900105002 p H

Code 9900105003 p H

Code 9900105005 p H

Code 9900105006 p H

Code 9900105007 p H

Code 9900105008 p H

SRH-1-1.5M Code 9900105031 R e d o x

SRH-1- 6M Code 9900105032 R e d o x

SRH-3 PT Code 9900105033 R e d o x

SRH-4 HT - PT Code 9900105034 R e d o x

pH/Redox Probes

2÷12 50 μS/cm 0÷60°C 0÷4 bar Epoxy Glass GEL 1 Ceramic 1,5m cable + BNC Standard Ø 12

2÷12 50 μS/cm 0÷60°C 0÷6 bar Epoxy Glass GEL 1 Standard 6m cable + BNC Standard Ø 12

2÷12 50 μS/cm 0÷60°C 0÷6 bar Epoxy Glass GEL 1 Standard S7 PG 13.5

2÷12 5 μS/cm 0÷80°C 0÷6 bar Glass Glass GEL 1 Open hole S8 PG 13.5

0÷14 5 μS/cm 0÷130°C 0÷6 bar Glass Glass GEL 2 Single Pore S8 PG 13.5

0÷14 5 μS/cm 0÷130°Cat 6 bar

0÷16 barat 25°C Glass Glass GEL 3 Ceramic S8 PG 13.5

0÷14 0.2 μS/cm -10÷40°C 0,5 bar Glass Glass GEL 1 Sleeve S7 PG 13.5

±1000mV - 0÷60°C 0÷4 bar Epoxy Platinum

wire GEL 1 Ceramic 1,5m cable + BNC Standard Ø 12

±1000mV - 0÷60°C 0÷6 bar Epoxy Platinum

wire GEL 1 Standard 6m cable + BNC Standard Ø 12

±2000mV - 0÷80°C 0÷6 bar Glass Platinum

wire GEL 1 Open hole S8 PG 13.5

±2000mV -

0÷130°Cat 6 bar

0÷16 barat 25°C Glass Platinum

wire GEL 3 Ceramic S8 PG 13.5

SRH-1 6M - AU Code 9900105083 R e d o x±2000

mV - 0÷60°C 0÷6 bar Epoxy Gold GEL 1 standard 6m cable + BNC Standard Ø 12

* S7 connection: it is a electrical connection only** S8 connection: S7 on the top electrical probe connection and PG 13.5 mm mechanical connection

Measure range

seko > water & industry > control and measuring instruments16

Features:l Costant Cell:

- 0,1 cm¯¹ or K=10- 0,2 cm¯¹ or K=5- 1,0 cm¯¹ or K=1

l Body material: PVC (60°C )l Electrodes material: Stainless steel 316L l Mechanical Connection: ½ Gas M Pvc

Field Application:

· Waste Water

· Drinking Water

· Cooling Towers

· Irrigation

C-K10/5 /1 CT-K10

Features:l Costant Cell: 1 cm¯¹ or K=1l Body material: Glass (130°C )l Electrodes material: Platinuml Mechanical Connection: ∅12 mm

Field Application: - Waste Water- Drinking Water- Cooling Towers- Boiler- Reverse Osmosis- CIP- Irrigation- Fish Farming- Dairy

C-K1 PT

Features:l Costant Cell: 0,1 cm¯¹ or K=10l Body materia:l PP (80°C) l Electrodes material: Stainless steel 316Ll Mechanical Connection :¾ Gas M PP

Field Application:

- Waste Water

- Drinking Water

- Cooling Towers

- Reverse Osmosis

- Irrigation

CT-K5

Features:l Costant Cell: 0,1 cm¯¹ or K=10l Body material: PP (80°C) l Electrodes material: Stainless steel 316Ll Mechanical Connection: ¾ Gas M PP

Field Application:

- Waste Water

- Drinking Water

- Cooling Towers

- Reverse Osmosis

- Irrigation

Without temperature sensor

Without temperature sensor With temperature sensor (PT100)

CT-K1

Features:l Costant Cell: 0,1 cm¯¹ or K=10l Body material PP (80°C) l Electrodes material: Stainless steel 316Ll Mechanical Connection: ¾ Gas M PP

Field Application:

- Waste Water

- Drinking Water

- Cooling Towers

- Reverse Osmosis

- Irrigation

With temperature sensor (PT100)With temperature sensor (PT100)

The seko range of conductivity probes is speciallydesigned for use in industrial environments inconjunction with seko measurement instruments.The various available models make it possible to coveran extremely wide measurement range. There areversions with temperature sensors and special versionswith graphite or platinum probes, PTFE cell bodies andIP67 connectors.

Measurement of conductivity is performed bysuspending the two metallic electrodes of the probe inthe solution to be measured. The passage of the currentbetween the two electrodes indicates the electricalresistance of the liquid, and therefore its conductivity.

The measurement is influenced by the temperature. Insaline solutions, measurement variations of 2% / °C canoccur. This variation can even reach 7% / °C. Therefore,conductivity probes without temperature sensors shouldonly be used if the solution being tested is maintainedat a temperature between 15°C and 25 °C, restricting thepotential for error to 10%.

Note All the models are guaranteed for a maximumpressure of 6 bars.

Conductivity Probes

innovation > technology > future 17

C-K10 Code 9900101012

C-K5

C-K1

C-K1-PT

CT-K10

CT-K5

CT-K1

Mea

sure

men

tra

nge

Cons

tant

[C-K

]

Tem

pera

ture

rang

e

Pres

sure

rang

e

Body

mat

eria

l

Mou

ntin

gPr

oces

s

Cabl

e

W i t h o u t t e m p e r a t u r e

Code 9900101011 W i t h o u t t e m p e r a t u r e

Code 9900101010 W i t h o u t t e m p e r a t u r e

Code 9900101013 W i t h o u t t e m p e r a t u r e

Code 9900101103 ( P T 1 0 0 ) W i t h t e m p e r a t u r e

Code 9900101102 ( P T 1 0 0 ) W i t h t e m p e r a t u r e

Code 9900101101 ( P T 1 0 0 ) W i t h t e m p e r a t u r e

Conductivity Probes

0,01÷500μS C=0,1 cm-1 K=10cm 60°C 6(*) PP-AISI 316 1/2” G.M. 5 m

0,1÷1000μS C=0,2 cm-1 K=5cm 60°C 6(*) PP-AISI 316 1/2” G.M. 5 m

1÷5000μS C=1 cm-1 K=1cm 60°C 6(*) PP-AISI 316 1/2” G.M. 5 m

1÷20000μS C=1 cm-1 K=1cm 120°C 6(*) Glass - Platinum Ø 12 mm 6 m

0,01÷500μS C=0,1 cm-1 K=10cm 80°C 6(*) PP-AISI 316 3/4” G.M. Plug (**)

Plug (**)

Plug (**)

0,5÷2000μS C=0,2 cm-1 K=5cm 80°C 6(*) PP-AISI 316 3/4” G.M.

5÷5000μS C=1 cm-1 K=1cm 80°C 6(*) PP-AISI 316 3/4” G.M.

(*) The maximum pressure of 6 bars is guaranteed at 25 °C. As the temperature increases, the pressure decreases linearlyand at 50° or 80 °C, the maximum pressure is 1 bar.

(**) To be used in conjunction with CC series cables.

Measure range

CT-K1-SS

Features:l Costant Cell: 0,1 cm¯¹ or K=10l Body material: PVDF (80°C) l Electrodes material: Stainless steel 316Ll Mechanical Connection: ¾ Gas M PP

Field Application:

- Waste Water

- Drinking Water

- Cooling Towers

- Reverse Osmosis

- Irrigation

CT-K1-GR

Features:l Costant Cell: 0,1 cm¯¹ or K=10l Body materia:l PVC (60°C) l Electrodes material: Graphite l Mechanical Connection: ¾ Gas M PP

Field Application:

- Waste Water

- Drinking Water

- Cooling Towers

- Reverse Osmosis

- Irrigation

With temperature sensor (PT100)With temperature sensor (PT100)

Features:l Costant Cell: 1 cm¯¹ or K=1l Body material: PVC (60°C )l Electrodes material: Graphite l Mechanical Connection: ∅12 mm

Field Application:

- Waste Water

- Drinking Water

- Cooling Towers

- Reverse Osmosis

- CIP

- Irrigation

- Fish Farming

CT-K1 G

With temperature sensor (PT100)

Mea

sure

men

tra

nge

Cons

tant

[C-K

]

Tem

pera

ture

rang

e

Pres

sure

rang

e

Body

mat

eria

l

Mou

ntin

gPr

oces

s

Cabl

e

7 m

5 m or 10 m

5 m or 10 m

CT-K1-G Code 9900101124 ( P T 1 0 0 ) W i t h t e m p e r a t u r e

5÷20000μS C=1 cm-1 K=1cm 60°C 6(*) PVC Graphite PG 13,5 mm

CT-K1-SS ( P T 1 0 0 ) W i t h t e m p e r a t u r e

1÷20000μS C=1 cm-1 K=1cm 100°C 6(*) PTFE 1” G.M.

CT-K1-GR ( P T 1 0 0 ) W i t h t e m p e r a t u r e

1÷20000μS C=1 cm-1 K=1cm 50°C 6(*) PVC 1” G.M.

Conductivity Probes

Measure range

Code 9900316009 (5m) 9900316010 (10m)

Code 9900316007 (5m) 9900316008 (10m)

(*) The maximum pressure of 6 bars is guaranteed at 25 °C.As the temperature increases, the pressure decreases linearlyand at 50° or 80 °C, the maximum pressure is 1 bar.

seko > water & industry > control and measuring instruments18

Conductivity Probes

19

Inductive Probes

Ind

uctive Probes

The S411/IND series of inductive sensors has been engineered and developed to produce an electrodethat is very powerful but at the same time competitive. The result has been obtained by moulding the sensormade using polypropylene reinforced with fibreglass.

This sensor offers all the advantages of the inductive cond. measurement method, including the absenceof passivation of the conventional conductivity electrodes. All the sensors in the S411/IND range are temperature-compensated, and are also designed for inline, submersion or tank installation.

SENSOR S411/IND

-5 to 60 °C (without freezing)

Glass-reinforced polypropylene

Inductive Probes

Temperature

Contact materials

PT1000 wiresTemp. compensation

Standard 5 metreCable

½" BSP maleConnection

IP67Protection rating

PVC with Viton gasketsMaterials

-5 to 60 °C (without freezing)Operating temperature

600 or 1200 mmSubmersion length

Standard bracket or optional flangeAssembly

From vacuum to 6.5 bar (100 psi)Operating pressure

1000 μS to 1 SimensConductivity Range

100 μS to 1000 μSResolution

Code 6100011441

Measure range Inductive Probes

S411/IND S411/IND/E S411/IND/T IN

S411/IND/T

innovation > technology > future

Inductive Probes

The OXYSENS® is anelectrochemical oxygen sensordesigned for applications in water,e.g. waste water treatment,swimming pools or fish farms. It iseasy to maintain, because themembrane and the electrolytedon’t need to be replaced. Theresponse time of the OXYSENS® isfast, it is almost independent offlow and insensitive to soiling.

OXYSENS®

The S423/N/OPT sensor with anintegrated temperature sensor isbased on luminescent opticaltechnology. Without calibrationrequirements and thanks to anultra low power technology, theS423/N/OPT sensor meets thedemands of field works and shortor long term campaigns. Withoutoxygen consumption, thistechnology allows you an accuratemeasure in all situation andespecially in very low oxygenconcentrations.

The S423/N/OPT sensor storescalibration and history data withinthe sensor. This allows you a “plugand play” system without re-calibration. Thanks to the UniversalModbus RS485 protocol, TheS423/N/OPT sensor can beconnected to all devices commonlyused (Datalogger, Controller,Automat, Remote System…).

S423/C OPT

The paddlewheel flow sensorSFW is designed to be used withevery kind of solid-free liquid.The sensor can measure flowfrom 0.15 m/s (0.5 ft/s)producing a frequency outputsignal highly repeatable.

A new electronic, with a push-pull output, is now available fora safe connection to any kind ofPLC/instrument digital input.

A special family of fittingsensures installation into all pipematerial in sizes from DN15 toDN600 (0.5" to 24").

SFWThe SFWE insertion magmeterscan measure flow rate in bothmetal and plastic pipes.No moving parts allow themeasurement of liquids withsuspended solids as long asconductive and homogeneous.The sensors can be assembled intothe standard FLS fittings forinstallation from DN15 to DN600(0.5" to 24").They offer frequency output to usewith FLS flow instrumentation and4-20 mA output for long distancetransmission and PLC connection.Special versions for salt-waterapplications (high concentration ofchlorides as sea water) and for hightemperature conditions.

SFWE

Flow

Sens

or

Flow

Sens

or

Dis

solv

ed O

xig

en P

robe

s

Dis

solv

ed O

xig

en P

robe

s

Flow Sensor

seko > water & industry > control and measuring instruments20

Dissolved Oxigen Probes

OXYSENS® S423/C OPT (35mm)Measurement of the electrical current affected by the

partial pressure of oxygen Optical measure by luminescence

40ppb÷40ppm 0,00 to 20,00 mg/L / 0,00to 20,00 ppm / 0-200% [Resolution 0,01]

Dissolved Oxigen Probes

Measuring method

Measurement of the electrical current affected by thepartial pressure of oxygen Optical measure by luminescence

-Modbus RS-485 (standard)

and SDI-12 (option)

Measuring method

Signal interface

Water applications: Waste water treatment,swimming pools, fish farms; composting facilities

Urban wastewater treatment, industrial effluenttreatment, surface water monitoring, drinking waterApplication fields

Square wave, frequency: 45 Hz per m/s [13.7 Hz per ft/s] nominal4÷20 mA with K330 output kit mounted

4÷20 mA - Isolated Square wave, frequency: 0-500HzOpen collector: flow directionOutputs

5 to 24 VDC ± 10% regulated 12 to 24 VDC ± 10% regulated(reverse polarity and short circuit protected)Power supply

Measurement range

< 0.5% [relative to current in air] ± 0,1mg/L / ±0,1 ppm / ±1%Accuracy

98% Max. 60 s at 25 °C 90% of the value in less than 60 secondsResponse time

≥ 0.03 m/s No necessary moveRequired flow

NTC 22 kOhm CTNTemperature sensor

-10÷60°C -10÷60°CStorage temperature

0÷60°C 0÷50°CTemperature range

0÷4 Bar 0÷5 BarPressure range

Stainless steel 1.4435, silicone, EPDM Stainless Steel INOX 316LBody material

OPTIFLOW No membraneMembrane material

Silver platinum combination No electrolyteReference electrolyte

5 m cable 10 m cableElectrical connection

4500 -Minimum reynolds

±0.75% of full scale ±1% of reading +1.0 cm/sLinearity

±0.5% of full scale ±0.5% of readingRepeatability

16 bar - 25°C8.6 bar - 70°C

Maximum processPressure/Temperature

PG 13.5 35mmMechanical mounting

-670 ± 50 mV 5 to 12 voltsPolarization voltage

Code 9900316005

Code 990031701X PVC SFW1 / SFW2Code 990031704X Stainless Steel SFW1 / SFW2 Code 9900317041 Mag SFW2

Code 9900317040 Mag SFW1

Measure range Flow SensorSFW SFWE

0.15 to 8m/s [0.5 to 25ft/s] 0.15 to 8m/s [0.5 to 25ft/s]

Flow Sensor

Working range

PVC-Cbody:10 bar - 25°C1.5 bar - 80°C

PVDFbody:10 bar - 25°C1.5 bar - 100°C

Brass&SSbody:25 bar - 120°C25 bar - 100°C

Water and waste water treatment, raw water intake, industrialwater distribution, textile industry, swimming pools, Spas andaquariums, HVAC, processing and manufacturing industry.

Application fields

Materials Sensor body:CPVC or PVDF

or 316L SS

O-rings:EPDMor FPM

Rotor:ECTFE

(Halar®)

Shaft:Ceramic(Al2O3)

Bearings:Ceramic(Al2O3)

Sensorbody:316L SS

PVDF

O-rings:EPDMor FPM

Electrodes:

316L SS

Dissolved Oxigen Probes

Water and industrial waste water treatment, water distribution,processing and manufacturing industry, textile finishing, chemicalproduction, cooling and Heating systems, swimming pools and Spas.

Code 9900105091 35mm

innovation > technology > future 21

Measure range

Models F-CL 1 F-CL 2 F-CL 3 F-CL 4 F-CL 5 F-CL 6 F-CL 7 F-CL 8 F-CL 9 F-CL 10

0÷10 ppm 0÷200ppm

0÷2ppm

0÷1ppm

0÷5ppm

0÷1ppm

0÷5ppm

0÷0,5ppm

Measurerange

4÷8 pH 4÷12 pH 4÷11 pH 4÷8 pH 5÷9 pH 4÷8 pH

F-CL 11

0÷5ppm

4÷8 pHpH range

1 minutes - 90% of measure (100% of measure after 15 minutes)Response time

30 L/h 80 L/h 30 L/hFlow rate

45 °C 50 °C 70 °C 45 °C

Silver chlorine with gold

Temperature

Silver chlorine with gold GoldSensor material

Wire connection with screwElectricalconnection

Ø 24mmMechanicalmounting

InorganicFree

Chlorine

Code9900101140

Code9900101141

Code9900101142

Code9900101146

Code9900101148

Code9900101149

Code9900101150

Code9900101152

Code9900101153

Code9900101159

Code9900101173

OrganicFree

ChlorineInorganic Free Chlorine

Applicationfields

M20Membrane

Pote

ntio

stat

icPr

obes

CLPROBES

M48 M48G

M20 M20–

M20 M20

ECL1Electrolyte

ECC1 ECS1Gel

ECL1 ECL1EAS1 Gel

ECL1 ECL1

This range consists of potentiostatic amperometric probes tomeasure free or total chlorine for applications such as: watertreatment, swimming pools, industrial applications and more.

The wide range of probes allows a better choice depending onthe parameter to be tested, thus obtaining a more accuratemeasurement.

l The two-wire interface allows quick and easy installation.

l Calibration of the probe is guided by theKontrol CL500 instrument .

(*) with Snap-RingF-CL 2 • F-CL 3 • T-CL 1 can be used in sea water application with special electrolites

Measure range

1 bar 0,5 bar 5 bar (*) 8 bar (*) 0,5 bar 1 barPressure

seko > water & industry > control and measuring instruments22

Potentiostatic Probes

CLPr

obes

Hol

der

M20

l In/Out: 8x12 mm (tube)l Material Plexiglas without colorl Hydraulic - By Passl Pressure 5 barl Temperature 60°C

FeaturesPSS-PLEXI

Code 9900103047 PSS-PLEXI [FLUX/PH]Code 9900103048 PSS-PLEXI [FLUX/PH/RX]Code 9900103049 PSS-PLEXI [FLUX/CL-A]Code 9900103050 PSS-PLEXI [FLUX/PH/CL-A]Code 9900103051 PSS-PLEXI [FLUX/PH/RX/CL-A]Code 9900103052 PSS-PLEXI [FLUX/PH/CL-P]Code 9900103053 PSS-PLEXI [FLUX/CL-P]Code 9900103054 PSS-PLEXI [FLUX/PH/RX/CL-P]Code 9900103055 PSS-PLEXI [FLUX/PH/RX/CL-A/CL-P]Code 9900103056 PSS-PLEXI [FLUX/CL-P/CL-P]

F-CL12 F-CL13 T-CL 1 T-CL 2 D-CL D-CL 2 D-CL 3 PAA 1 H202 1 H202 2

0÷2ppm

0÷5ppm

0÷10ppm

0÷10ppm

1÷14 pH

0÷1ppm

0÷2000ppm

0÷200ppm

0÷500ppm

4÷12 pH 4÷11 pH 4÷14 pH 5÷9 pH 2÷11 pH

1 minutes - 90% of measure (100% of measure after 15 minutes)

30 L/h 80 L/h 30 L/h

45 °C 50 °C 70 °C 45 °C

Silver chlorine with gold Gold Silver chlorine with gold

Wire connection with screw

Ø 24mm

OrganicFree

Chlorine

Code9900101174

Code9900101177

Code9900101143

Code9900101172

Code9900101144

Code9900101151

Code9900101154

Code9900101157

Code9900101158

Code9900101156

InorganicFree

ChlorineTotal Chlorine Chlorine Dioxide

Per AceticAcid

Hydrogen Peroxide Ozone Bromine

M48 M48 M48M48– EPS7/W

M20 M20

ECC1

M48G

ECS1Gel

EDC41EAS1 Gel M7N EOZ1

EBR1Gel

03 1

0÷2ppm

1÷14 pH

Code9900101175

03 2

0÷5ppm

Code9900101176

BR 1

0.05÷10ppm

6.5÷9.5 pH

0,5 bar 1 bar 5 bar (*) 8 bar (*) 1 bar 5 bar (*) 1 bar 0,5 bar

Code9900101179

Potentiostatic Chlorine Probesinnovation > technology > future 23

and Modular probe holder

ECP1Gel

ECP1Gel

seko > water & industry > control and measuring instruments24

Turbidimetric Probesand Suspended Solid probes

The principle of measurement is the deviation oflight produced by suspended particles in theliquid. Thanks to the dual sensor is possible tomake measurements of turbidity at low and verylow concentrations with high accuracy andrepeatability.

Avoiding contact with the measuring liquid, theoptical LED technology make the system stableover time and minimize the need for re-calibration. The cell is installed directly in line, themaximum allowable pressure is 4 or 6 bar, pipe orbypass. The flow velocity does not affect themeasurement.

Turb

idim

etri

cpr

obes

Features:· Black Plastic Body

· Turbidity Measure with Led light with

Field Application:

· Waste water

· Drinking Water

· Swimming pool

· Sewage Treatment

S462/PVC/SWP

Turb

idim

etri

cpr

obes Features:

· SS AISI 316 material

· Turbidity Measure with Ledlight with Resistors sensor

· Threaded Connection 1" GAS

· Cables included

Field Application:

· Sewage Treatment

· Sludge application

· Waste water

· Fish farming

S461/T

Turb

idim

etri

cpr

obes

Features:· SS AISI 316 material

· Solid Measure with Led lightwith Resistors sensor

· Threaded Connection 2 1/2" M GAS

· Two cables included

Field Application:

· Sewage Treatment

· Drinking Water

· Waste water

· Cleaning in place

S462/SS

Resistors sensorThreaded Connection 1" GAS

Cables included

Resistors sensorThreaded Connection 1" GAS

Cables included

Susp

ende

d So

lids

prob

es

Features:· SS AISI 316 material

· Solid Measure with Led lightwith Resistors sensor

· Threaded Connection 1" GAS

· Cables included

Field Application:

· Sewage Treatment

· Sludge application

· Waste water

S461/S

Resistors sensorThreaded Connection 1" GAS

Cables included

Resistors sensorThreaded Connection 2 1/2" F GAS

Two cables included

Features andBenefitsReliable concentration measurementusing optical measuring process

Infrared light pulsing beams scattering method

Black rigid PVC sensor body

No mechanically moving parts

Measured value pre-processing in sensorresulting in low signal transmission sensitivity

innovation > technology > future 25

S462/PVC

Scattering at 180°Light absorption

Scattering at 180°Light absorption

Scattering at 90°Light absorption

0÷45°C

0÷6bar

12÷24 Vdc

12÷24 Vdc

12÷24 Vdc

2 cables5m

- Water treatment plants , downstream offiltration and decantation.Process section;

- Aging facilities of wastewater reuse foragricultural or industrial purposes;

- Food industry particularly in theproduction of beverages, wine, beer etc.;

- Pool water.

S462/SS

0,00÷100NTU/FTU

0,00÷/4/40 /400

/4000

0,00÷100NTU/FTU

0÷90°C

0÷6bar

5mcable

S461/T

0÷60°C

0÷4bar

10mcable

Wastewater, primary water, industrialwater, recirculating water.

Mea

sure

men

tm

etho

d

Mea

sure

men

tra

nge

Tem

pera

ture

rang

e

Pres

sure

rang

e

Pow

ersu

pply

Elec

tric

alco

nnec

tion

2½“F

2½“M

1“GASTh

read

edco

nnec

tion

Appl

icat

ions

field

Measure range

Code 9900316021

PVC blackTransparent PVC door

Stainless Steel INOX 316Tempered glass window

Stainless Steel INOX 316Special Optical Glass or Viton

Body

mat

eria

l

T u r b i d i m e t r i c

Code 9900316006

Code 9900316022 T u r b i d i m e t r i c

Turbidimetric ProbesMeasure range

Sospended Solid Probes

S461/S

Scattering at 90°Light absorption

0÷60°C

0÷4bar

10mcable

Wastewater, primary water, industrialwater, recirculating water.

20 gr/l

Mea

sure

men

tra

nge

Mea

sure

men

tra

nge

Tem

pera

ture

rang

e

Pres

sure

rang

e

Pow

ersu

pply

Elec

tric

alco

nnec

tion

1“GAS

Thre

aded

conn

ecti

on

Appl

icat

ions

field

Code 9900316025

Stainless Steel INOX 316Special Optical Glass or Viton

Body

mat

eria

l

S o s p e n d e d S o l i d

Scattering at 180°Light absorption

12÷24 Vdc

12÷24 Vdc

0,00÷40NTU/FTU

S462/SWP

0÷45°C

0÷6bar

2 cables5m

Pool water2½“FPVC blackTransparent PVC door

Code 9900316024 T u r b i d i m e t r i c

T u r b i d i m e t r i c

seko > water & industry > control and measuring instruments26

Suspended Solid Probes

The 7520 SAV and 7540 SRH sensors areused for optical solids contentmeasurement in turbid water for up to150g solid matter/l.

Susp

ende

d So

lids

prob

es

7520 SAV-T/E

Susp

ende

d So

lids

prob

es

7540 SRH-T/E

l Solids content measurement ofsuspended matter in sewage treatmentplants: Primary sludge, digested sludge,thickened sludge, Inflow to centrifuge /press.

l Industrial quality control.

Applications

Features andBenefits

Reliable concentration measurementusing optical measuring process.

Infrared light pulsing beams scattering

method.

Black rigid PVC sensor body.

No mechanically moving parts.

Measured value pre-processing insensor resulting in low signaltransmission sensitivity.

Susp

end

ed S

olid

Prob

e

innovation > technology > future 27

7520 SAV-T/E 7540 SRH-T/E

139 x 38 ∅ mm 134 x 38 ∅ mm

220 x 38 ∅ mm 220 x 38 ∅ mm

Suspended Solid Probes

Mechanical data Dimension (Lx∅)Immersion type

Dimension (Lx∅)Installation type

Approx. 1Kg Approx. 1KgWeightImmersion type

Approx. 3Kg Approx. 3KgWeightInstallation type

Stainless steel SS 316 Ti Stainless steel SS 316 TiMaterials Sensor Body

Epoxy resin Epoxy resinSight glass

Viton® Viton®O-rings

0÷150°C 0÷150°COperating conditions Op. temperature

max 6 bar max 6 barOp. pressure

IP 68 IP 68Protection

Light absorption method Backscatter light methodMeasurement

range

Measuring principle

Light source 2 LEDs detectors 2 photodiodes Light source 2 LEDs detectors 2 photodiodesOptical components

Infrared light at 880 mmabsorption maximum

Infrared light at 880 mmabsorption maximumMeasuring light

0÷50g solid matter/l,dependent on sludge type

10÷150g solid matter/l,dependent on sludge typeMeasuring range

< 1% of measuring range end value < 1% of measuring range end valueAccuracy

Using four-beam pulsed light method Using four-beam pulsed light methodReference

T version 13mE version 1m + 10m extension cableCable lengths

With silica standard With silica standardCalibration

On demandOn demand

Measure range

Suspended Solid Probes

T version 13mE version 1m + 10m extension cable

seko > water & industry > control and measuring instruments28

Cables, buffer solutions and probe accessoriesImmersion probe holders

Sensors for measuring pH,Redox and Conductivitymust be installed in thesystem using special probeholders that ensure thecorrect mechanicalprotection and degree ofimpermeability.The pH and Redoxmeasurement probes canbe submerged in tanks,inserted in pipes or placedin sample draw downcontainers (Catch Pots).

The immersion models withadjustable flange can be used inconjunction with a counter-flangewhich allows quick and easyinstallation and removal. The P-IGrange with a floating platformadapts to the varying liquid level ofdeep water tanks. Thepolypropylene versions PIR-2-PP-xxx can house two sensors, e.g. pHand Redox.It is not recommended to use PHand/or Redox sensor in the sameprobe holder as a conductivity cell.

Prob

e A

cces

sori

es

Imm

ersi

onpr

obe

hold

er

PI

PI PVC 400 Code 9900100111

400 mm 1 40°C PVC

PI PVC 800 Code 9900100112

800 mm 1 40°C PVC

PI PVC 1000 Code 9900100115

1000 mm 1 40°C PVC

PI PVC 1500 Code 9900100113

1500 mm 1 40°C PVCIm

mer

sion

No.

of p

robe

s

Max

Tem

pera

ture

Mat

eria

lPIR PVC 200 Code 9900100101

100÷250 mm 1 40°C PVC

PIR PVC 400 Code 9900100102

100÷450 mm 1 40°C PVC

PIR PVC 800 Code 9900100103

100÷850 mm 1 40°C PVC

PIR PVC 1000 Code 9900100105

100÷1050 mm 1 40°C PVC

PIR PVC 1500 Code 9900100106

100÷1550 mm 1 40°C PVC

Imm

ersi

on

No.

of p

robe

s

Max

Tem

pera

ture

Mat

eria

l

Imm

ersi

onpr

obe

hold

er

PIRPVC

PI PVC 2000 Code 9900100116

2000 mm 1 40°C PVC

innovation > technology > future 29

PIR 2PP

Imm

ersi

onpr

obe

hold

er

PIR 2 PP 400 Code 9900100121

100÷450 mm 2 80°C PP

PIR 2 PP 800 Code 9900100122

100÷850 mm 2 80°C PP

PIR 2 PP 1000 Code 9900100124

100÷1050 mm 2 80°C PP

Imm

ersi

on

No.

of p

robe

s

Max

Tem

pera

ture

Mat

eria

l

PICIR PP 400 Code 9900100141

100÷450 mm 1 80°C PP

PICIR PP 800 Code 9900100142

100÷850 mm 1 80°C PP

PICIR PP 1000 Code 9900100144

100÷1050 mm 1 80°C PP

PICIR PP 1500 Code 9900100145

100÷1550 mm 1 80°C PP

Imm

ersi

on

No.

of p

robe

s

Max

Tem

pera

ture

Mat

eria

l

PCIRPP

Imm

ersi

onpr

obe

hold

er

PI G

PI G Code 9900100131

Floating 1 40°C PVC

B PI G Code 9900100132

2m anchorage arm - 40°C PVC

Imm

ersi

on

No.

of p

robe

s

Max

Tem

pera

ture

Mat

eria

l

Imm

ersi

onpr

obe

hold

er

FER

FER Code 9900100133

65 mm 140 mm 40°C4 holesØ 6 mm

Int.

Dia

met

er

Ext.

Dia

met

er

Max

Tem

pera

ture

Conn

ecti

on

PP

Mat

eria

l

Coun

ter-

flang

e

for quick removal

Probe holders with 3/4”probe attachment without protectionThese can house conductivity probes with threaded 3/4” G.Attachment with output cable or IP67 connector.

Probe Accessories

seko > water & industry > control and measuring instruments30

By-P

ass p

robe

hol

der

PSS 7 Single

By-pass 1 40°C 6 bar

PSS 7

By-pass 3 40°C 6 bar

Conn

ecti

on to

the

proc

ess

No.

opr

obes

Max

Tem

pera

ture

Max

Pre

ssur

e

Code 9900103021

Code 9900103008

PSS 7A

By-pass 3 40°C 6 bar

Code 9900103010

Tap probe holdersTap probe holders are used for in-line measurements where part ofthe sample is re-directed fromthe main pipe to the probeholder. The water can be drawnoff into the sampling circuit at apressure of 6 bars.

PSS 7Single

PSS 7PSS 7A

Back

was

hpr

obe

hold

er

PIAPVC

PIA PVC 400

400 mm 1 40°C 2÷6

PIA PVC 800

800 mm 1 40°C 2÷6

Imm

ersi

on

No.

of p

robe

s

Max

Tem

pera

ture

Max

Pre

ssur

e

100÷600

100÷600

1/h

Min

- M

ax

Code 9900100151

Code 9900100152

Immersion probeholders with spraycleaning These special probe holders canbe connected with a cleaningliquid injection unit. Regularcleaning of the probe ensureslinearity and stability of themeasurement over time,preventing the need for time-consuming manual intervention.Pr

obe

Acc

esso

ries

Cables, buffer solutions and probe accessoriesAccessories

innovation > technology > future 31

Out

flow

prob

e ho

lder

Probe Accessories

Pres

suri

zed

prob

e ho

lder

PSS 3

1/2” G.M. PG 13,5 or Ø 12 mm 60°C 7 bar

SPP

1” G.F. PG 13,5 60°C 16 bar

Conn

ecti

on to

the

proc

ess

Mec

hani

cal

Conn

ecti

on

Max

Tem

pera

ture

Max

Pre

ssur

e

PVC

PP + PVC

Mat

eria

l

Code 9900106670

Code 9900100134

SPP FIL

3/4” or 1” 1/4 G.M. PG 13,5 80°C 16 bar PP

Code 9900100135

Pressurized probeholdersPressurised probe holders areused to immerse the probedirectly into the pipe where thesample to be measured passes.The probe must always bepositioned vertically or slantingin the direction of the flow at amaximum of 45°. The probeholder connection line must befitted between two isolationvalves (input and output) inorder to permit the prevention ofthe flow during maintenance ofthe probes.

PSS 3

PSS-EC

SPP FILSPP

Outflow probe holdersfor conductivity probesBypass probe holder for conductivity probe model CTK1, 5 and 10

Made of black PVC with 3/4” mechanical connection and 1” GAS IN/OUT hydraulics.

OUTFLOW SECTION (PSS-COND-T)

Code 0000126035

seko > water & industry > control and measuring instruments32

Cables, buffer solutions and probe accessoriesAccessories

Prob

e A

cces

sori

es

Tem

pera

ture

sens

or

PT 100 NUT

3/4" GAS M

PT 100V

5 m 3-wire cable Standard Ø 12

Conn

ecti

on

Mec

hani

cal

Conn

ecti

on

PVC

Pyrex

Mat

eria

l

Code 9900101113

Code 9900105061

PT 100V PG

6 m 3-wire cable PG 13,5 Pyrex

Code 9900105062

TemperatureprobesIn order to correctly measurethe pH in environments withvariable temperatures, it isnecessary to correct theresponse error of the proberesulting from temperaturechange. The measuringinstrument must therefore beconnected to a specialtemperature sensor.

PT 100NUT

PT 100V PT 100VPG

Tem

pera

ture

sens

or

Electrical surge suppressor Allows the elimination of Eddy currentsAISI 304 material - Ø 12 mm.

Max Pressure 7 bar

Code 9900101134

RNC

1 m 2-wire cable

PT 100 NUT

1/2” GAS M PVC

Code 9900101113

1 m 2-wire cable

innovation > technology > future 33

Prob

eca

bles

CC

CE 1/B

1 mt. Mod. RG58 5 mm

CE 5/B

5 mt. Mod. RG58 5 mm

Leng

th

Type

of C

able

Crimping BNCSoldered BNC

Crimping BNCSoldered BNC

Term

inal

blo

ck

Code CE 9900108001 CEB 9900109001

Code CE 9900108003 CEB 9900109003

Code CE 9900108004 CEB 9900109004

Code CE 9900108006 CEB 9900109006

Code CE 9900110001 CEB 9900110101

Code CE 9900110002 CEB 9900110102

Code CE On demand CEB 9900110103

CE 10/B

10 mt. Mod. RG58 5 mmCrimping BNCSoldered BNC

CE 20/B

20 mt. Mod. RG58 5 mmCrimping BNCSoldered BNC

CE 10 HT(*)/B

10 mt. Mod. HT 5 mmCrimping BNCSoldered BNC

CE 20 HT(*)/B

20 mt. Mod. HT 5 mmCrimping BNCSoldered BNC

CE 30 HT(*)/B

30 mt. Mod. HT 5 mmCrimping BNCSoldered BNC

Cables forCTK Probewith 4-pole connectors

CC 5

5 mt. standard

CC 10

10 mt. standard

Leng

th

Vers

ion

4

4

No. p

oles

Code 9900110111

Code 9900110112

CC 15

15 mt. standard 4

Code 9900110113

Probe cables withS7 heads

Prob

eca

bles

CE

CE B

(*) HT - High Quality Cablefor higher protection fromelectical interference.

Probe Accessories

seko > water & industry > control and measuring instruments34

Cables, buffer solutions and probe accessoriesAccessories

Prob

e A

cces

sori

es

Prob

eca

bles

PE 10 /B

PE 10/B

10 mt. Mod. RG58 5 mm

PE 20/B

20 mt. Mod. RG58 5 mm

Leng

th

Type

of C

able

Crimping BNCSoldered BNC

Crimping BNCSoldered BNC

Term

inal

blo

ck

PE 20 HT(*) /B

20 mt. Mod. HT 5 mmCrimping BNCSoldered BNC

PE 30 HT(*) /B

30 mt. Mod. HT 5 mmCrimping BNCSoldered BNC

Extension Cables forBNC-F ProbeBNC-M Probe

(*) HT - High Quality Cablefor higher protection from electicalinterference.

Buffe

rsol

utio

n

ST PH

ST PH 4

pH 4,00 pH 20 °C

ST PH 7

pH 7,00 pH 20 °C

Solu

tion

Valu

e

250 ml

250 ml

Qua

ntity

Code 9900122007

Code 9900122008

ST PH 9

pH 9,22 pH 20 °C 250 ml

Code 9900122009

ST RX 465

Redox 465 mV 25 °C 250 ml

Code 9900122010

Certified buffersolutions

The precision and reliability of a pH,Redox or Conductivity measure-ment is determined by the buffersolution used for calibrating theprobe. The special double-plug con-tainer ensures that a new unpol-luted buffer is always available.

ST RX

ST MS 8

Conductivity 84 μS/cm 25°C

ST MS 14

Conductivity 1423 μS/cm 25°C

500 ml

500 ml

Code 9900122018

Code 9900122019

ST MS 128

Conductivity 12880 μS/cm 25°C 500 ml

Code 9900122020

ST MS

Code PE 9900108007 PEB 9900109007

Code PE 9900108008 PEB 9900109008

Code PE 9900110004 PEB 9900110104

Code PE 9900110005 PEB 9900110105

innovation > technology > future 35

ASV

Redu

ctio

nFl

ange

DEH

UM

IDIF

IER

Sign

al a

mpl

ifier

s

ASV Code TPM032VX0000

pH / Redox Amplifier Voltage Batterylasts 4 years

Mea

sure

men

t

Func

tion

Out

put

Pow

er su

pply

Dehumidifier andreduction flangefor Turby Sensor

Signal amplifiersBattery-poweredlive ASV signal amplifier In order to connect a pH or Redoxmeasurement probe at a distance ofover 15 meters, it is necessary to usethe ASV signal amplifier to beconnected between the probe cableand the extension cable of themeasurement instrument.

REDUCTIONFLANGE2”1/2 to 1/2” GAS F IN/OUT

DEHUMIDIFIERPower supply 230 Vac 50Hz4x6 mm hydraulic connections

Code 9900316011 Code 9900316012

Probe Accessories

For more information

seko is an International Group, developing, manufacturing and delivering its products in more than 50 countries,through its subsidiaries and an extended network of distributors, agents and authorized dealers.

seko is a leading manufacturer of dosing pumps and dosing systems with more than 40 years experience. This longactivity allowed seko to acquire a vast experience in diversified applications and to confirm its international successin many industrial fields through the supply of reliable solutions for the dosing, injection and transfer of liquids.

A Worldwide Group at your service

Ertek Yapı ve Makina Endüstri Ekipmanları San. ve Tic. Ltd. Ști.

Halkapınar Mah. Pamuk Plaza İș Merkezi 1082 Sokak No: 3 M 35170 Yenișehir Konak / İZMİR Tel: (0232) 469 43 53 Faks: (0232) 457 46 51

www.ertek.com • [email protected]

www.ertek.com