Radiographic Contrast Media

RAD TECH 255 SPECIAL PROCEDURES

MERRILLS VOL2RTA BOOK CH 19

Page 3: Contrast media 1

Subject Contrast

• Range of differences in the intensity of the x-ray beam, after it has been attenuated by the subject (patient).

Page 4: Contrast media 1

Low Subject Contrast

What can be done to attain medical information-

• see the difference between muscle, organs or vessels

Define and outline – organ structure and function

Page 5: Contrast media 1

Contrast media

• Defines subtle differences in subject contrast

• Increases atomic number of area injected

• Results in a SHORTER scale of subject contrast

Page 6: Contrast media 1

Purpose of Contrast Media

• To enhance subject contrast or render high subject contrast in a

tissue that normally has low subject contrast.

Page 7: Contrast media 1

Atomic Number

• Fat = 6.46

• Water = 7.51

• Muscle = 7.64

• Bone = 12.31

Page 8: Contrast media 1

Radiographic Contrast : Influenced by…

• Radiation Quality (KVP)

• Film Contrast

• Radiographic object (Patient)

Page 9: Contrast media 1

KVP TYPE OF CONTRAST USED DETERMINES KVP RANGE•

BARIUM 90 – 120 kVp

IODINES 70 – 80 kVp(Ionic / Nonionic Water or Oil)

Page 10: Contrast media 1

INJECTABLECONTRAST MEDIA

for RT 255 procedures

INVASIVE PROCEDURESThe “o-grams”

Page 11: Contrast media 1

ALWAYS TAKE

A “SCOUT”

BEFORE CONTRAST INJECTION

√ PATHOLOGY

√ TECHNIQUE

√ PREP & PRIOR CONTRAST

√ POSITIONING

Page 12: Contrast media 1

SPECIAL “o-grams”

• Venogram• Arthrogram• Sialogram• Myelogram• Arteriogram• Angiogram• Galactogram• Hystersalpingogram…….. etc

Page 13: Contrast media 1
Page 14: Contrast media 1
Page 15: Contrast media 1

CONTRAST INJECTION

Page 16: Contrast media 1

DOUBLE CONTRAST WITH IODINE - HIP Arthorgram

Page 17: Contrast media 1

To check fertility

Page 18: Contrast media 1
Page 19: Contrast media 1

LYMPHANGIOGRAM

Page 20: Contrast media 1

Galactography - Breast Duct

Page 21: Contrast media 1

Cerebral Angiogram

Page 22: Contrast media 1
Page 23: Contrast media 1

SPECIAL PROCEDURESARE INVASIVE

ALWAYS GET PATIENT’S HISTORY AND CONSENT BEFORE

BEGINNING OR GIVING ANY CONTRAST

MEDIA

Page 24: Contrast media 1

CONSENTS

• SIGNED AND WITNESSED• AFTER PROCEDURE HAS BEEN EXPLAINED• CHECK DEPARTMENT PROTOCOL• WHO’S RESPONSIBLE ??????

Page 25: Contrast media 1

CONSENTS

• ASSAULT verbal threat of harm

• BATTERYUnlawful touching - unauthorized treatment“X-RAY” TAKEN ON WRONG PATIENT

• FALSE IMPRISONMENTRestraints require permission

from patient or authorized person

Page 26: Contrast media 1

BLOOD WORK LAB TESTS to check function of kidneys prior to

injection of contrast • WATCH THE UPPER LIMITS• BUN = BLOOD UREA NITROGEN• Merrills pg 214 range is 8 to 25 pg 242 range is 10 - 20

always check with RAD when level above 20• CREATININE levels range:• pg 214 (0.6 - 1.5) pg 242 (0.05 - 1.2)

always check with RAD when level above 1.2 • Indicates function of kidneys • Diseases / dehydration / kidney failure

Page 27: Contrast media 1

EGFR (new test)

• Estimated • Glomerular • Filtration • Rate

• More advanced test for • CREATININE levels

Page 28: Contrast media 1

Review of Contrast Agents

Types of ContrastRoutes of AdminstrationChemical Components

Page 29: Contrast media 1

Contrast Media changes the density of the organs

Therefore changing the Subject contrast will change the Radiographic contrast and film contrastMay need to INCREASE TECHNIQUE FROM SCOUT IMAGE

Page 30: Contrast media 1

Contrast Media (review)

• Negative contrast• (AIR OR CO2)

• Radiolucent

• Low atomic # material

• Black on film

• Positive contrast • (all others)

• Radiopaque

• High atomic # material

• White on film

Page 31: Contrast media 1

Types of Contrast Media

• Radiolucent-• negative contrast agent• x-rays easily penetrate • areas- appear dark on films

Negative Contrast Media• Air and gas

• complications• emboli-air pockets in

vessels• lack of oxygen

• Radiopaque- • positive contrast agent- • absorbs x-rays• appears light

Positive Contrast Agents• BARIUM • IODINES

Both + & - can be used in same study

Page 32: Contrast media 1

2 BASIC TYPESOF CONTRAST material

• BARUIM Z# 56

• NON WATER SOLUABLE

• GI TRACT ONLY INGESTED OR RECTALLY• KVP 90 – 120*

• IODINE Z# 53• WATER SOLUABLE• POWDER• LIQUID• INTRAVENOUS OR• Intrathecal• GI TRACT• Also OIL based• KVP BELOW 90*

Page 33: Contrast media 1

Methods of Administrationof Contrast Material

• INGESTED – (ORAL)

• RETROGRADE – AGAINST NORMAL FLOW

• INTRATHECAL – Spinal canal

• PARENTERAL (IV, Intrathecal)– Injecting into bloodstream– (anything other than oral)

Page 34: Contrast media 1

Contrast media for SPECIAL PROCEDURES

Diagnostic agents that are injected into

• Circulatory System, Joint Spaces, Ducts

• Body orifices/organs: uterus, breast, salivary & lymph glands

Page 35: Contrast media 1

BARIUM – a review

BARUIM SULFATENot used in Special Procedures

Page 36: Contrast media 1

Barium Sulfate

• High atomic number• Not soluble in water• Used to coat the lining of organs• Supplied in different thicknesses• Used

– Esophogram, UGI, Small Bowel,Lower GI or BE

Page 37: Contrast media 1

Ba ADVERSE REACTIONS

• BARIUM INERT• SUSPENSION MAY CAUSE ALLERGY• OCG TABLETS (IODINE) ALLERGY• AFTER EXAM – MAY SOLIDIFY DIFFICULT TO

EVACUATE• INCREASE FLUIDS, MILD LAXATIVE

• EXTRAVASATION OF CONTRAST INTO PERITONEUM

Page 38: Contrast media 1

Extravasation of BA in abd

Page 39: Contrast media 1

Ingested CONTRASTGastrografin or Hypaque

• High atomic #– Close to iodine

• Water soluble

• Similar usage as Barium

Page 40: Contrast media 1

GASTROGRAFINAdverse Reactions

• Water soluble, safe in the abdominal cavity–Safe to use if perforation is suspected

• Very harmful to the lung tissue–Do not use if aspiration is possible

Page 41: Contrast media 1

Gastro – Pathology present

• Bowel • Obstruction

• Note contrast• Seen in

kidneys as well

Page 42: Contrast media 1

IODINEIONIC OR NON IONIC

WATER OR OIL BASE

Page 43: Contrast media 1

IODINATED CONTRASTiodine z # 53

• WATER BASED

• INJECTED• VESSELLS/DUCTS• INGESTED• Organ function/flow• OPEN WOUNDS

• OIL BASED• INJECTED• NEVER VESSELLS• ONLY DUCTS• NOT INGESTED• OPEN WOUNDS

Page 44: Contrast media 1

INJECTION OF IODINEinto Vessels

• ALWAYS A WATER BASED IODINATED COMPOUND

• BOLUS INJECTION• INFUSION DRIP

• IONIC VS• NON IONIC• CONTRAST

• 50 -70 % CONCENTRATE

Page 45: Contrast media 1

IODINE WATER BASED CONTRAST

• IONIC• LESS $$$

• MORE REACTIONS

• NON IONIC• MORE $$$

• LESS REACTIONS

Page 46: Contrast media 1

CONTRAST MEDIAIODINE

is either: IONIC or NON-IONIC • Osmolarity• # Of Particles (Cations + And Anions -)

– In Solution Per Kilogram Of Water• High Osmolarity

– =more Cations And Anions• Can Upset Homeostasis• Nonionic Have No Charged Particles

Page 47: Contrast media 1

Contrast AgentsIONIC• High Osmolality

(Higher risk of complications)

– Diatrizoate sodium (Hypaque)

– Iothalamate meglumine (Conray)

NON-IONIC• Low Osmolality

(Lower risk of complications)

• Gadodiamide (Omniscan) – Iodixanol (Visipaque) – Iopamidol (Isovue) – Iopromide (Ultravist) – Ioversol (Optiray)

Page 48: Contrast media 1

• Less money• More reactions

• More money• Less reactions

Page 49: Contrast media 1

OIL – BASED

IODINECONTAST

Instilled in ORGAN

Page 50: Contrast media 1

Oil Based Iodine• Fatty Acids• Insoluble in water

– White on the radiograph = Radiopaque• Uses

– Broncography (lungs)– Tear ducts– Salivary glands– Lymphatic system– Hysterrosalpingogram– Galactography (breast ducts)

• FAT EMBOLUS IF IT GETS INTO • BLOOD VESSEL

Page 51: Contrast media 1

Newer Contrast Agents Balance Safety and Visualization