CONNTRACTOOR PLAN SUBMIT

 

   

TAL

 

 

OBTAINING FIRE SUPPRESSION PERMITS

o Complete commercial permit application (copy available on building

department website: http://www.cityhall.lima.oh.us/index.aspx?NID=196

o Submit 4 sets of plans for review

o 1 set will be forwarded to the fire department having jurisdiction for comment

o Upon approval 2 sets will be returned to contractor with permit

o Building department will email copy of permit to fire department having

jurisdiction upon issuance. (see Contact List – Appendix A)

o Ready for system installation when permit has been issued

SYSTEM INSTALLATION

o System is to be installed in accordance with all approved construction

documents

o System must be installed as code compliant in accordance with all NFPA

standards and building codes.

 

 

SCHEDULING INSPECTIONS

o Contractor completes and sends (via fax or email) a fire protection request form (see appendix B) to fire department having jurisdiction.

o Contractor to call fire inspector to schedule inspection date and time.

o Fire inspector to notify building department of scheduled inspection date and time.

o Tests and inspections to be witnessed jointly by fire inspector and

building inspector.

o All new and modified systems affecting more than 20 heads shall be tested at 200 psi without loss of pressure for 2 hours.

EXCEPTION: modifications that cannot be isolated shall

not require testing in excess of system working pressure.

INSPECTION OF LIMITED AREA OR MODIFIED SYSTEMS HAVING 20 HEADS OR LESS

o Fire inspector and building inspector reviews construction documents for approvals and completeness.

o Inspectors verify that all piping and devices are according to approved documents (OBC 109.1).

o Inspectors will give final approval upon compliance of all system

components.

INSPECTION OF NEW OR MODIFIED SYSTEMS HAVING MORE THAN 20 HEADS

o Fire inspector and building inspector reviews construction documents for approvals and completeness.

o Inspectors verify pressure gauge for 200psi and begin 2-hour hydrostatic test.

o Inspectors verify that all piping and devices are according to approved

documents (OBC 109.1).

o If no loss of pressure and no violations were observed, the inspectors will sign the building permit.

 

 

o If violations including loss of pressure were observed, the inspectors

will leave an inspection form identifying the violations.

o If system is to be covered by ceilings or other building finishes, an additional inspection may be necessary to verify pipe installation is in compliance with approved plans before concealment.

o If sprinkler piping is to be painted, it must be inspected by the building

inspector prior to covering to ensure the correct type of pipe was installed.

o The fire alarm acceptance test and approval of all newly installed

tamper switches, flow or alarm devices must be completed prior to scheduling a final suppression inspection.

o Contractor must provide a completed material and test certificate. (see

Appendix C – Contractor’s Material and Test Certificate for Above ground Piping)

o Inspectors review construction documents for approvals and

completeness.

o Inspectors will verify the installation of the Hydraulic calculation sign, stock of spare sprinkler heads and general information sign. NOTE: spare special sized heads are not required.

o Inspectors will check for signage on all valves.

o Inspectors will verify head type and placement.

o Inspectors will check to ensure a ceiling is provided for pendant heads

when applicable and escutcheon plates are installed.

o Inspectors will check for obstructions to the sprinkler heads.

 

 

o If lenebusude

violations wave an inspeeded. If nouilding permuppression evices, inclu

were observpection repoo violations mit under Fisystem willuding any r

ved during ort form onwere obse

ire Suppresl not be grarequired off

the inspect site identif

erved the inssion Final.anted prior tf-site monito

tion the insfying the cospectors w Final apprto testing floring.

pectors wilorrections will sign the roval of the ow and tam

l

fire mper

Department Chief Addresss Phone E‐mail

Allen County EMA Russ Decker 333 N. Main St. Lima, Ohio 45801 419‐993‐1404 [email protected]

American Twp FD Tom Hadding 105 W. Main St. Elida, OH 45807 419‐339‐3921 [email protected]

Bath Twp. FD Joseph Kitchen 1787 N. Dixie Hwy. Lima, OH 45801 419‐221‐0550 [email protected]

Beaverdam‐Richland FD Bob Swisher 201 W. Main St. Beaverdam, OH 45808 419‐643‐3891 [email protected]

Bluffton FD Jon Kinn 402 N. Main St. Bluffton, OH 45817 419‐358‐8606 firechief@bluffton‐ohio.com

Bluffton EMS Jan Basinger P.O. Box 63 Bluffton, OH 45817 419‐358‐8606 basingerj@bluffton‐ohio.com

Cairo‐Monroe Twp. FD Wes Buettner 101 W. Main St. Cairo, OH 45820 419‐641‐5735 [email protected]

Delphos FD Kevin Streets 125 E. 2nd St. Delphos, OH 45833 419‐695‐2911 [email protected]

Harrod FD Lynn Dray

123 N. Walnut St. Harrod, OH 45850     P.O. 

Box 227 Harrod, OH 45850 419‐648‐4282 [email protected]

Invincible Fire Co. Dave Evans 204 S. Canal St. Spencerville, OH 45887 419‐647‐4615 [email protected]

Lafayette‐Jackson Twp. FD Bob Hutchinson

215 E. Sugar St. Lafayette, OH 45854               

P.O. Box 7107 Lafayette, OH 45854 419‐649‐3791 [email protected]

Lima FD Mark Heffner 433 S. Main St. Lima, OH 45804‐1287 419‐221‐5160 [email protected]

Perry Twp. FD Rick Phillips 2408 E. Breese Rd. Lima, OH 45806 419‐221‐2345 [email protected]

Shawnee Twp. FD Todd Truesdale 2526 Ft. Amanda Rd. Lima, OH 45804 419‐222‐2986 [email protected]

Spencerville EMS Julie Sheets 111 S. Pearl St.Spencerville, OH 45887 419‐647‐6369 [email protected]

Westminster Rural FD Jordan Striff 682 Faulkner Rd. Harrod, OH 45850 419‐648‐6443 [email protected]

ALLEN COUNTY FIRE DEPARTMENT CONTACTS APPENDIX A

 

 

Appendix B

Fire Protection Inspection Request Form

 

Jobsite Address:

Scheduled Date & Time:

Fire Alarm Witness Test Fire Suppression Permit No.

Fire Suppression Hydrostatic Test

HVAC Test Fire Alarm Permit No.

Electrical System Test

Suppression Rough-in

Final Suppression

Contractor Contact Person:

Contact Phone No.

No. Fire Alarm Devices No. Fire Alarm Devices No. HVAC Devices No. Electrical Systems

   Manual Pull Stations Egress Control Devices Smoke Control System Generator Test

   A/V Units Hold Open Devices Duct Detectors Fire Pump Test

   Smoke/ Heat Detectors Fire Shutter Smoke Dampers

Fire Suppression

Systems    Electric Strikes Sprinkler Flow Alarm Hood/Suppression Alarm

   Other: Sprinkler Tamper Device FM 200 Sprinkler Heads

   Stairway Pressurization Risers

Fire Protection Company:

F/A Installer Signature: Date:

F/S Installer Signature: Date:  

Print Form

jfm9300
Text Box
Appendix C
jfm9300
Text Box
Aboveground Piping Certificate (page 1)
jfm9300
Text Box
jfm9300
Text Box
Aboveground Piping Certificate (page 2)
jfm9300
Text Box
jfm9300
Text Box
jfm9300
Text Box
Aboveground Piping Certificate (page 3)
jfm9300
Text Box