4
^ HAMMOND mm www.hammfg.com 1418 304 Stainless Steel Single Door Enclosures - NEMA 4X Continuous Hinge, Clamped Cover 0.4' nw 3 _^__^ * Y t ---. 1 - """"Kn ,_r°_ r_ i L 1 r ej i L 1 * j 1 1 n EH 3.25 X-«- ~| J z t •-2.00 v 2.00 "^ | r n*] i ~ ~ i iioii i LJ i i-1 * "'Hi::*- > 1 1 LI l_l © a \ il * l\ : \ Lr \<a ^ 'C ^ ii^ L •- r— |_ i ^f lh- r & ~~ fi\ 1 ^ F - 1 i ]- €) _/ s -O -(L 1 i 0.88 : I 0.88 2.00 . 1 IT /- BONDING / STUD = $>- GROUND /STUD 3 t ^_j o n ) -r£= «t «S 50 1 n. i f _ T. I J f M TYP J_ When A= 30 36 42 48 60 M= 7.00 9.00 9.88 11.38 14.38 Front View Side View -"• [-•-0.94 4 •*s PIANO HINGE M2.38 A ^CENTER OF DOOR _N»j ~ir H yritr GASKET .375-16 COLLAR STUD \ 12 GA V TPANEL \£b t ft *0.88| 1 1.20 t 0.75 ^L \ t BODY STIFFENER -J /MOUNTING FEEf 0 19 Section Y-Y 0.63 Section Z-Z O Vertical stiffener required on KK, LL & M only. © Omit center body stiffener if A is less than 41". © Padlocking hasp and staple. O Omit 2 middle studs if A is less than 31". © Omit body stiffeners if A or B is less than 29". © Omit 2 middle studs if B is less than 31". O Omit door stiffener if A or B is less than 31" except if AxB is 42"x30". Literature pocket supplied loose. Number of door clamps varies to enclosure size. Panel Size Mtg.Centers Part No. 1418N4SSB6 2 1418N4SSG6 2 1418N4SSCR6 2 1418N4SSC6 2 1418N4SSD6 2 1418N4SSE6 1418N4SSB8 1418N4SSC8 2 1418N4SSD8 2 1418N4SSER8 1418N4SSH8 1418N4SSE8 1418N4SSJ8 1418N4SSKR8 1418N4SSF8 1418N4SSK8 1418N4SSKK8 1418N4SSL8 A 16 16 16 '20 20 24 16 20 20 20 24 24 24 24 30 30 30 36 B 12 16 20 16 20 20 12 16 20 24 16 20 24 30 20 24 30 24 C 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8 8 D 13 13 13 17 17 21 13 17 17 17 21 21 21 21 27 27 27 33 E 9 13 17 13 17 17 9 13 17 21 13 17 21 27 17 21 27 21 F 9.5 10,0 14.0 10.0 14.0 14.0 9.5 10.0 14.0 18.0 10.0 14.0 18.0 24.0 14.0 18.0 24.0 18.0 Ship G Wt. Ibs. 17.25 17.25 17.25 21.25 21.25 25.25 17.25 21.25 21.25 21.25 25.25 25.25 25.25 25.25 31.25 31.25 31.25 37.25 28 30 38 38 40 61 32 38 52 61 61 61 75 89 72 89 100 100 Panel Size Part No. 1418N4SSM8 1418N4SSP8 1 1418N4SSS8 1 1418N4SSC10 1418N4SSE10 1418N4SSL10 1418N4SSM10 1418N4SSO10 1 1418N4SSJ12 1418N4SSK12 1418N4SSM12 1418N4SSLL12 1 1418N4SSS12 1 1418N4SST12 1 1418N4SSK16 1418N4SSM16 1418N4SSS16 1 A 36 42 48 20 24 36 36 42 24 30 36 36 48 60 30 36 48 B 30 36 36 16 20 24 30 30 24 24 30 36 36 36 24 30 36 C 8 8 8 10 10 10 10 10 12 12 12 12 12 12 16 16 16 D 33 39 45 17 21 33 33 39 21 27 33 33 45 57 27 33 45 E 27 33 33 13 17 21 27 27 21 21 27 33 33 33 21 27 33 Mtg.Centers Ship F 24 30 30 10 14 18 24 24 18 18 24 30 30 30 18 24 30 1 Meets UL standards G 37.25 43.25 49.25 21.25 25.25 37.25 37.25 43.25 25.25 31.25 37.25 37.25 49.25 61.25 31.25 37.25 49.25 2 Flat Wt. Ibs. 121 177 207 47 66 108 125 17S 71 95 136 202 225 270 100 149 290 panel Meets UL standards : Flat panel Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise © Hammond Manufacturing Quality Enclosures. Service Excellence. Canada: 519.822.2960 or 905.456.3770 USA: 716.631.8281 Data Subject to change without notice W1

Continuous Hinge, Clamped Cover · PDF fileNEMA 250-1997. Type 2 Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with

Embed Size (px)

Citation preview

^ HAMMONDmm

www.hammfg.com

1418 304 Stainless Steel Single Door Enclosures - NEMA 4XContinuous Hinge, Clamped Cover

0.4'nw

3

_^__^

* Y

t

---.

1 -

""""Kn,_r°_r_

iL1

r

ej

iL1

*j1

1 nEH3.25

X-«-~|J

z

t

•-2.00

v

2.00 — "| r

n*] i ~ ~i

i ioii iLJ i i-1 *

"'Hi::*-> 1 1

LI l_l

©

a\

il * l\ :— \ Lr\<a ^

'C

^

ii

L•-

r—|_

i

^f

lh-

r

&

~~

fi\

1

„^

F

- 1i

]-

€)_/s

-O-(L

1

i

0.88 :

I

0.88

2.00

.

1

IT

/- BONDING/ STUD

= $>- GROUND/STUD

3 t^_j o n«

n

)

— - r£=«t

«S

50

1

n.

i

f_T.

I

J

fM

TYP

J_

When A=

3036424860

M=

7.009.009.88

11.3814.38

Front View Side View

-"• [-•-0.94

4

•* —

s PIANOHINGE

M2.38

A

^CENTER OF DOOR

_N»j~i — rHyritr

GASKET

.375-16COLLAR STUD

\ 12 GAV TPANEL\£b t ft

*0.88|

1 1.20

t

0.75

^L\ t BODY STIFFENER -J /MOUNTING FEEf

0 19 Section Y-Y

0.63

Section Z-Z

O Vertical stiffener required on KK, LL & M only.© Omit center body stiffener if A is less than 41".© Padlocking hasp and staple.O Omit 2 middle studs if A is less than 31".© Omit body stiffeners if A or B is less than 29".© Omit 2 middle studs if B is less than 31".O Omit door stiffener if A or B is less than 31"

except if AxB is 42"x30".

Literature pocket supplied loose.Number of door clamps varies to enclosure size.

Panel Size Mtg.CentersPart No.

1418N4SSB62

1418N4SSG62

1418N4SSCR62

1418N4SSC62

1418N4SSD62

1418N4SSE61418N4SSB8

1418N4SSC82

1418N4SSD82

1418N4SSER81418N4SSH8

1418N4SSE81418N4SSJ8

1418N4SSKR81418N4SSF8

1418N4SSK81418N4SSKK8

1418N4SSL8

A

16

1616

'2020241620202024

24242430303036

B

12

1620162020121620241620243020243024

C

6

66666888

88

8888888

D

13

13131717

21131717

1721212121272727

33

E

913171317179

1317

2113172127172127

21

F

9.5

10,014.0

10.014.014.09.5

10.014.0

18.010.014.018.024.014.018.024.018.0

ShipG Wt. Ibs.

17.2517.2517.2521.2521.2525.2517.2521.2521.2521.2525.25

25.2525.25

25.2531.2531.2531.2537.25

283038384061323852

61616175

897289

100100

Panel SizePart No.

1418N4SSM81418N4SSP81

1418N4SSS81

1418N4SSC101418N4SSE10

1418N4SSL101418N4SSM10

1418N4SSO101

1418N4SSJ12

1418N4SSK121418N4SSM12

1418N4SSLL121

1418N4SSS121

1418N4SST121

1418N4SSK16

1418N4SSM161418N4SSS161

A

364248

2024

36364224

3036364860303648

B

303636162024303024

2430

3636

36243036

C

888

1010101010121212

1212

1216

1616

D

3339451721

33333921273333455727

3345

E

27

33331317212727212127

333333212733

Mtg.Centers ShipF

24

30301014

182424181824

303030182430

1 Meets UL standards

G

37.25

43.2549.25

21.2525.25

37.2537.25

43.2525.25

31.2537.25

37.2549.25

61.2531.2537.2549.252 Flat

Wt. Ibs.

1211772074766

108125

17S7195

136202225270100149290

panel

Meets UL standards : Flat panel

Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise

© Hammond Manufacturing

Quality Enclosures. Service Excellence.Canada: 519.822.2960 or 905.456.3770 USA: 716.631.8281 Data Subject to change without notice

W1

*• HAMMONDWT E N C L O S U R E S

www.hammfg.com

s£>13i|s§51*&8S 8'Isr- 3

fd

I

1418 304 Stainless Steel Single Door Enclosures - NEMA 4XContinuous Hinge, Clamped Cover

Application• Designed for use as instrument

enclosures, electric, hydraulic orpneumatic control housings,electrical junction boxes or terminalwiring enclosures.

• Provides protection whereequipment may be hosed down orotherwise be very wet, or in specificapplications where corrosion is aserious problem.

Standards• UL 508 Type 3R, 4, 4X, and 12• CSA Type 3R, 4, 4X, and 12• Complies with

« NEMAType3R, 4, 4X, 12 and 13« JIC EGP-1-1967 unless marked1

« I EC 529, IP66

Construction• Formed 14 gauge Type 304

stainless steel bodies and doors.• Smooth, continuously welded seams

without knockouts, cutouts or holes.» Door and body stiffeners are

provided in the larger enclosures forextra rigidity.

• Welded brackets provide forenclosure mounting.

• Formed lip on door and enclosureexcludes flowing liquids andcontaminants.

• Stainless steel continuous hinge .ondoor may be removed by pulling thestainless steel hinge pin.

• Door is secured with easily operatedstainless steel clamps.

• Provision for padlocking.« Oil resistant gaskets are permanently

secured and mechanically retained." A removable 12 gauge inner panel is

included.• Collar studs are provided for

mounting inner panels.• A bonding stud is provided on the

door and a grounding stud isprovided in the enclosure.

» A literature pocket is provided for theinside of the door.

InnerPanel

Included

Finish* Cover and enclosure are natural

stainless steel with a smoothbrushed finish.

» Removable inner panel is finished inwhite powder coating.

Accessories« Additional inner panels...see page 380* Air conditioners...see page 347-353* Blowers...see page 357" Breather kits...see page 371* Door clamping hardware...see page 374* Door Stop kits...see page 389

" Drip Shield kits...see page 389* Enclosure stabilizers...see page 393

* Filter fans...see page 358-365* Floor Stand kits...see page 390

* H eate rs... see page 368-369* Lock kit...see page 375* Louvered ventilating plates...see page 392* Quick release clamp...see page 374

« Terminal kit assemblies...see page 383

* Thermostats...see page 377" Window kits...see page 387

Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise

100© Hammond Manufacturing

Quality Enclosures. Service Excellence.Canada: 519.822.2960 or 905.456.3770 USA: 716.631.8281 Data Subject to change without notice

£ HAMMONDHr I

General AccessoriesPanels & Panel Accessories

www.hammfg.com

Panels for 1414 Series and PJ Series Enclosures14 gauge steel panels are finishedin white.

• Aluminum panels are 0.080 type5052 H-32 aluminum, unpainted.

" Panels and mounting hardware areincluded with 1414 Seriesenclosures.

" Mounting hardware is included withPJ Series enclosures, order panelseparately.

For Use WithSteel AluminumPart No. Part No.

14R050314R0505 14A050514R0705 14A0705

14R070714R0907 14A090714R090914R110514R1109 14A110914R1111

14R130714R1311 14A131114R150914R1513 14A1513

P1868 A1868P2068 A2068

PanelLength

4.88

4.886.75

6.758.75

8.7510.7510.7510.75

12.7512.75

14.7514.7516.8818.44

Width

2.88

4.884.88

6.886.88

8.884.888.88

10.88

6.8810.88

8.8812.8814.8814.44

1414Height Width

6

68

810

1012

1212

1414

1616—

4

66

88

106

1012

812

1014—

For Use WithPJ Series

Height Width— —

7.04 7.04 :8.94 7.06_ _

11.08 9.20• — • ' — '— —

13.08 11.20— —— _""'':: •:'«:*

15.08 13.20_ —

17.22 15.34

19.34 17.34 : :

20.94 16.94

Panels for 1418, 1447, and Series 2000 Wallmount Enclosures

Cl§sr«&iv,MWor\fDin«O3-P«/»

12 gauge steel finished in white." Larger panels have two, or four

formed flanges.• Some larger panels are 10 gauge.• Panels and mounting hardware are

included with 1418 and 1447 Seriesenclosures.

• Mounting hardware is included withSeries 2000 enclosures, order panelseparately.

,

PanelPart No.

18P09091

18P092118P13091

18P13131

18P17091

18P17131iwr 1 1 117

18P17171

18P211318P2117

18P212118P2709

18P271318P271718P272118P2727

t8P332118P332718P333318P392118P392718P393318P452118P452718P453318P573318P6927 ff!f'K':>m18P69331 Flat Panel

Length

9

913

1317..—

17

2121

2127

2727

2727

3333

3339

3939

4545

4557

6969

Technical references and DXF downloads available at www.hammfg.com

Width

9

219

13 : :

9

1317

1317

219

1317

2127

2127

3321

2733

2127

3333

2733

All dimensions

For Use With EnclosureHeight

12

1216

1620

2020

2424

2430

3030

3030

3636

3642

4242

4848

Width

12

ms^l 24 :12

1612

16IV20

«-vv 16

20

24 ;:>4P;112

' • . • • : • • " { : : ' . 1.6. • ' : i • i - - : ' . ;20

: . :24. HI III

30

: . - . ' ; . . . • :24:--:.30

36 vpSf24

30 3Si36

2430

48 3660

7272

in inches

36

."'!?"• 3036

unless specified otherwise

380© Hammond Manufacturing

Quality Enclosures. Service Excellence.Canada: 519.822.2960 or 905.456.3770 USA: 716.631.8281 Data Subject to change without notice

*i HAMMONDmm E N C L O S U R E S

www.hammfg.com

Industry Definitons (NEMA Standards)

»3-3

?'&)

3

|Hi

|

Definitions Pertaining to Non-Hazardous LocationsType 1 Enclosures constructed for indoor use to provide adegree of protection to personnel against incidental contactwith the enclosed equipment, and to provide a degree ofprotection against falling dirt. NEMA 250-1997.

Type 2 Enclosures constructed for indoor use to provide adegree of protection to personnel against incidental contactwith the enclosed equipment, to provide a degree ofprotection against falling dirt, and to provide a degree ofprotection against dripping and light splashing of liquids.NEMA 250-1997.

Type 3 Enclosures constructed for either indoor or outdooruse to provide a degree of protection to personnel againstincidental contact with the enclosed equipment; to provide adegree of protection against falling dirt, rain, sleet, snow,and windblown dust; and that will be undamaged by theexternal formation of ice on the enclosure. NEMA 250-1997.

Type 3R Enclosures constructed for either indoor oroutdoor use to provide a degree of protection to personnelagainst incidental contact with the enclosed equipment; toprovide a degree of protection against falling dirt, rain, sleet,snow; and that will be undamaged by the external formationof ice on the enclosure. NEMA 250-1997.

Type 3S Enclosures constructed for either indoor or outdooruse to provide a degree of protection to personnel againstincidental contact with the enclosed equipment; to provide adegree of protection against falling dirt, rain, sleet, snow, andwindblown dust; and in which the external mechanism(s)remain operable when ice laden. NEMA 250-1997.

Type 4 Enclosures constructed for either indoor or outdooruse to provide a degree of protection to personnel againstincidental contact with the enclosed equipment; to provide adegree of protection against falling dirt, rain, sleet, snow,windblown dust, splashing water, and hose-directed water;and that will be undamaged by the external formation of iceon the enclosure. NEMA -250 1997.

Type 4X Enclosures constructed for either indoor oroutdoor use to provide a degree of protection to personnelagainst incidental contact with the enclosed equipment; toprovide a degree of protection against falling dirt, rain, sleet,snow, windblown dust, splashing water, hose-directed water;and corrosion; and that will be undamaged by the externalformation of ice on the enclosure. NEMA -250 1997.

Type 5 Enclosures constructed for indoor use to provide adegree of protection to personnel against incidental contactwith the enclosed equipment; to provide a degree of protectionagainst falling dirt; against settling airborne dust, lint, fibers,and flyings; and to provide a degree of protection againstdripping and light splashing of liquids. NEMA 250-1997.

Type 6 Enclosures constructed for either indoor or outdooruse to provide a degree of protection to personnel againstincidental contact with the enclosed equipment; to provide adegree of protection against falling dirt; against hose-directed water and the entry of water during occasionaltemporary submersion at a limited depth; and that will beundamaged by the external formation of ice on theenclosure. NEMA-250 1997.

Type 6P Enclosures constructed for either indoor or outdooruse to provide a degree of protection to personnel againstincidental contact with the enclosed equipment; to provide adegree of protection against falling dirt; against hose-directedwater and the entry of water during prolonged submersion ata limited depth;. and that will be undamaged by the externalformation of ice on the enclosure. NEMA-250 1997.

Type 12 Enclosures constructed (without knockouts) forindoor use to provide a degree of protection to personnelagainst incidental contact with the enclosed equipment; toprovide a degree of protection against falling dirt; againstcirculating dust, lint, fibers, and flyings; and against drippingand light splashing of liquids. NEMA 250-1997

Type 12K Enclosures constructed (with knockouts) forindoor use to provide a degree of protection to personnelagainst incidental contact with the enclosed equipment; toprovide a degree of protection against falling dirt; againstcirculating dust, lint, fibers, and flyings; and against drippingand light splashing of liquids. NEMA 250-1997

Type 13 Enclosures constructed for indoor use to provide adegree of protection to personnel against incidental contactwith the enclosed equipment; to provide a degree of protectionagainst falling dirt; against circulating dust, lint, fibers, andflyings; and against spraying splashing, and seepage of water,oil and noncorrosive coolants. NEMA 250-1997

Definitions Pertaining To Hazardous (Classified)LocationsType 7 Enclosures constructed for indoor use in hazardouslocations classified as Class I, Division 1, Groups A, B, C, orD, as defined in NFPA70. NEMA 250-1997

Type 8 Enclosures constructed for either indoor or outdooruse in hazardous locations classified as Class I, Division 1,Groups A, B, C, or D, as defined in NFPA70. NEMA 250-1997

Type 9 Enclosures constructed for indoor use in hazardouslocations classified as Class II, Division 1,Groups E, F, or G,as defined in NFPA70. NEMA 250-1997

Type 10 Enclosures constructed to meet the requirementsof the Mine Safety and Health Administration, 30 CFR, Part18. NEMA 250-1997. NEMA 250-1997

Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise

398© Hammond Manufacturing

Quality Enclosures. Service Excellence.Canada: 519.822.2960 or 905.456.3770 USA: 716.631.8281 Data Subject to change without notice