12
VSD05M - SOLENOID OPERATED DIRECTIONAL VALVES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM CONTINENTAL HYDRAULICS SOLENOID OPERATED DIRECTIONAL VALVES VSD05M

CONTINENTAL HYDRAULICS · PDF filevsd05m - solenoid opera ted directional valve s 5505 west 123rd street • savage, mn 55378-1299 / ph: 952.895.6400

Embed Size (px)

Citation preview

Page 1: CONTINENTAL HYDRAULICS  · PDF filevsd05m - solenoid opera ted directional valve s 5505 west 123rd street • savage, mn 55378-1299 / ph: 952.895.6400

VSD05M - SOLENOID OPERATED DIRECTIONAL VALVES

5505 WEST 123RD STREET • SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM

CONTINENTAL HYDRAULICS

SOLENOID OPERATED DIRECTIONAL VALVESVSD05M

Page 2: CONTINENTAL HYDRAULICS  · PDF filevsd05m - solenoid opera ted directional valve s 5505 west 123rd street • savage, mn 55378-1299 / ph: 952.895.6400

2 WWW.CONTINENTALHYDRAULICS.COM - [email protected]

ACCURATEVS

D05M

- SO

LENO

ID O

PERA

TED

DIRE

CTIO

NAL V

ALVE

S

VSD05MSOLENOID OPERATED DIRECTIONAL VALVES

DESCRIPTIONThese valves conform to NFPA D05 and ISO 4401 mounting standards. They are available in both 3 way and 4 way styles.

All versions are available in 2 position spring offset, 2 position detent, 2 position spring centered and 3 position spring centered versions.

A wide range of spools are available.

Standard and CSA approved versions are available.

TYPICAL PERFORMANCE SPECIFICATIONS

MAXIMUM OPERATINGPRESSURE

P - A - B Ports

Standard 4600 psi 320 bar

CSA 4000 psi 275 bar

T Port DC

STD 3000 psi 210 bar

CSA 2500 psi 172 bar

AC ALL 2000 psi 140 bar

FLOW RATEDC 38 gpm 145 lpm

AC 32 gpm 120 lpm

MOUNTING SURFACENFPA D05,

ISO 4401-05-04-0-05

MAXIMUMWEIGHT

AC 8.0 lbs 3.6 kg

DC 10.6 lbs 4.8 kg

RANGE TEMPERATURES

Ambient - 4 to +130°F -20 to +54°C

FluidStandard - 4 to +180°F -20 to +82°C

CSA -4 to +150°F -20 to +66°C

FLUID VISCOSITY

Range 60 -1900 SUS 10 - 400 cSt

Recommended 120 SUS 25 cSt

FLUID CONTAMINATION ISO 4406:1999 Class 20/18/15

Page 3: CONTINENTAL HYDRAULICS  · PDF filevsd05m - solenoid opera ted directional valve s 5505 west 123rd street • savage, mn 55378-1299 / ph: 952.895.6400

[email protected] - WWW.CONTINENTALHYDRAULICS.COM 3

SEAL

A Buna (STD)

G Viton

MECHANICALOMIT IF NOT REQUIRED

RSingle Solenoid Operator At

‘B’ Port End.

WD Wash-Down

ELECTRICAL OPTION

OMITPlug-in terminal

solenoids or lead wires

BConnection box with

terminal posts and lights

VSD05M - L -- - -

TYPICAL ORDERING CODE:

VSD05M-3A-AB5A-60L-B VSD05M-3A-A-33L-B

IDENTIFICATION CODE

DESIGN LETTER

Spool TypeSee Next Page

SOLENOIDS - See the codes on page 10

VSD05M - SOLENOID OPERATED DIRECTIONAL VALVES

FUNCTION

1Single Solenoid

2 PositionSpring Offset

2Dual Solenoid

2 PositionDetented (No Spring)

3Dual Solenoid

3 PositionSpring Centered

5Single Solenoid

2 PositionSpring Centered

6Single Solenoid

2 PositionEnergize To Center

9Single Operator

2 Position - 3 WaySpring Offset

CONNECTION BOX OPTIONSOMIT IF NOT REQUIRED

See the codes on page 9

APPROVALS

OMIT STD VALVE

CSA CSA US/CAN

Page 4: CONTINENTAL HYDRAULICS  · PDF filevsd05m - solenoid opera ted directional valve s 5505 west 123rd street • savage, mn 55378-1299 / ph: 952.895.6400

4 WWW.CONTINENTALHYDRAULICS.COM - [email protected]

VSD0

5M -

SOLE

NOID

OPE

RATE

D DI

RECT

IONA

L VAL

VES

SPOOLS

NAME SYMBOL FUNCTION CENTER POSITION CROSSOVER FUNCTION MATCHING

A All ports blockedP→B or P→A

T blocked1, 2, 3, 5, 6

B All ports open All ports open 1, 2, 3, 5, 6

EP and A blocked,

and B→TAll ports blocked or

P and A blocked and B→T3, 5

FP blocked,

A→T and B→TP blocked and A→T or B→T

3, 5, 6

F1P blocked,

A and B restricted to TP blocked,

A or B restricted to T

3, 5

GP to A and B T blocked

P→B or P→A T blocked

HP and A to T,B blocked

All ports open, restricted

KP and B blocked,

and A→TP and B blocked and A→T

or all ports blocked

LP→T,

A and B blockedAll ports open, restricted

QP and B to T,

A blockedAll ports open, restricted 3, 5

X - All ports blocked 9

These are the standard configurations. Contact Continental Hydraulics for special versions.

Page 5: CONTINENTAL HYDRAULICS  · PDF filevsd05m - solenoid opera ted directional valve s 5505 west 123rd street • savage, mn 55378-1299 / ph: 952.895.6400

[email protected] - WWW.CONTINENTALHYDRAULICS.COM 5

VSD05M - SOLENOID OPERATED DIRECTIONAL VALVES

PRESSURE DROPS ∆P-Q SHIFTED VALVE(OBTAINED WITH VISCOSITY OF 170 SUS - 36 CST AT 70°F - 21°C)

PRESSURE DROPS ∆P-Q CENTRAL POSITION

SPOOLFLOW CURVE NUMBER

P→A P→B A→T B→T

A 2 2 1 1

B 3 3 1 1

E, F, F1, K, 1A, 2A, 1B, 2B 3 3 2 2

H, L, Q 1 1 2 2

G 1 1 1 1

SPOOLFLOW CURVE NUMBER

P→A P→B A→T B→T P→T

B, L, H, Q 5

E 6

F 6 6

G 3 3

K 6

PERFORMANCE CURVE

CURVE SPOOL

1 A, B, G, 9X

2 L

3 1A

4 1A-R

5 F

6 1B

7 F1

8 E, K

9 H, Q

DC VOLTAGE

Page 6: CONTINENTAL HYDRAULICS  · PDF filevsd05m - solenoid opera ted directional valve s 5505 west 123rd street • savage, mn 55378-1299 / ph: 952.895.6400

6 WWW.CONTINENTALHYDRAULICS.COM - [email protected]

VSD0

5M -

SOLE

NOID

OPE

RATE

D DI

RECT

IONA

L VAL

VES

NOTES:1. The values indicated in the graphs are relevant to the standard valve. The DC Performance Curve used a 42L coil, the AC Performance Curve used a 60L coil, and the AC Low Force Curve used a 68L coil. 2. Valve performance was tested in a four way circuit (full loop). Performances may be reduced from that shown when used in a three-way circuit (half circuit), i.e. A or B port plugged.3. The values have been obtained according to ISO 6403 norm with solenoids at rated temperature and supplied with voltage equal to 90% of the nominal voltage. The value have been obtained with filtration according to ISO 4406:1999 class 18/16/13.

PERFORMANCE CURVE

CURVE SPOOL

1 A, B, G, 9X

2 L

3 1A

4 F, F1

5 K, E

6 H, Q

CURVE SPOOL

1 1B, 2B, G

2 1B-R

3 1A

4 1A-R

5 B

6 A

7 2A

8 F

AC VOLTAGE

AC VOLTAGE - LOW FORCE

Page 7: CONTINENTAL HYDRAULICS  · PDF filevsd05m - solenoid opera ted directional valve s 5505 west 123rd street • savage, mn 55378-1299 / ph: 952.895.6400

[email protected] - WWW.CONTINENTALHYDRAULICS.COM 7

VSD05M - SOLENOID OPERATED DIRECTIONAL VALVES

OVERALL AND MOUNTING DIMENSIONS - CONNECTION BOX VERSIONDimensions in mm [IN]VSD05M-2*, 3*

Mounting surface with sealing rings:5 pcs.AS568-014 90 Shore A

Connection Box

Manual OverrideIntegrated in the Tube.

Manual OverrideIntegrated in the Tube.

Coil Removal Space

Coil Removal Space

SOL. ‘A’SOL. ‘B’

SOL. ‘B’

VSD05M-1*, 5*, 6*, 9*

Page 8: CONTINENTAL HYDRAULICS  · PDF filevsd05m - solenoid opera ted directional valve s 5505 west 123rd street • savage, mn 55378-1299 / ph: 952.895.6400

8 WWW.CONTINENTALHYDRAULICS.COM - [email protected]

VSD0

5M -

SOLE

NOID

OPE

RATE

D DI

RECT

IONA

L VAL

VES

OVERALL AND MOUNTING DIMENSIONS - DIN STYLE VERSIONDimensions in mm [IN]VSD05M-2*, 3*

VSD05M-1*, 5*, 6*, 9*

Mountingsurfacewith sealingrings: 5 pcs.AS568-014 90Shore A

Coil with DIN style shape (DIN 43650) Connector

DC Coil Shape: Round

AC Coil Shape: Square

Coil Removal Space

Coil Removal Space

SOL. ‘A’SOL. ‘B’

Manual OverrideIntegrated in the Tube.

Manual OverrideIntegrated in the Tube.

Page 9: CONTINENTAL HYDRAULICS  · PDF filevsd05m - solenoid opera ted directional valve s 5505 west 123rd street • savage, mn 55378-1299 / ph: 952.895.6400

[email protected] - WWW.CONTINENTALHYDRAULICS.COM 9

VSD05M - SOLENOID OPERATED DIRECTIONAL VALVES

ELECTRICAL CHARACTERISTICSValves are available with an electrical connection box or with DIN 43650 solenoids in both AC andDC voltages. Deutsch DT04 or lead wires are also available in DC voltages only.

CONNECTION BOX OPTIONSTo simplify the connections and prevent wiring mistakes, we offer the option with connection boxes with quick connect pin receptacles, already wired.

Valves are available with receptacles on solenoid side ‘A’ or ‘B’ and several connector styles.

Below are the codes to be included in the box ‘option’ of the ordering code, depending on theversion you choose.

Wiring diagrams below show the standard connections for 3-pin, 4-pin and 5-pin connectors. Thecommercially available mating “female” connector are not included.

CODE PIN SHAPE PORT END NOTES

5A 5Male Mini

A Single and DualSolenoid5H 5 B

3A 3Male Mini

ASingle Solenoid Only

3H 3 B

4A 4

Male Micro

A

For DC Current Only. Different Wiring.See Schematics.

D4A 4 A

4 4 B

D4 4 B

5 PIN RECEPTACLEMale mini receptacles conform to NFPA/T3.5.29 R1 - 2007 used with single or double solenoid valve.

26 mm [1” ] Wrench

3 PIN RECEPTACLEMale mini receptacles conform to NFPA/T3.5.29 R1 - 2007 used with single solenoid valve.

26 mm [1” ] Wrench

4 PIN RECEPTACLEMale micro receptacles (M12x1 thread) used with DC valve only.

23 mm [7/8] Wrench

1 Lead to Solenoid B2 Lead to Solenoid A3 Ground Lead (Green)4 Lead to Solenoid A5 Lead to Solenoid B

1 Ground Lead (Green)2 Lead to Solenoid3 Lead to Solenoid

4A & 41 Brown Lead to Solenoid A2 White No Connection3 Blue Common Lead to Sol. A & B4 Black Lead to Solendoid B

D4A & D41 Brown No Connection2 White Lead to Solenoid A3 Blue Common Lead to Sol. A & B4 Black Lead to Solendoid B

Page 10: CONTINENTAL HYDRAULICS  · PDF filevsd05m - solenoid opera ted directional valve s 5505 west 123rd street • savage, mn 55378-1299 / ph: 952.895.6400

10 WWW.CONTINENTALHYDRAULICS.COM - [email protected]

VSD0

5M -

SOLE

NOID

OPE

RATE

D DI

RECT

IONA

L VAL

VES

SOLENOIDSListed below the types of solenoids available and the numbers to be added in the solenoid box on page 3.

PLUG-IN TERMINAL SOLENOID DIN 43650 This solenoid has three terminal posts. Use bi-polar connectors that meet ISO 4400 / DIN 43650(EN 175301-803). Protection against atmospheric agent: IP 65

CONNECTION BOX SOLENOIDS This is a two pin solenoid which connects to the circuit board. Wiring is done on the terminal stripinside the box.

WASHDOWN OPTION (CODE WD)The wash-down option with the electrical box is designed for an IP65 rating. This option uses a special cover without the mounting bolt access holes and uses silicone sealant to help seal between the coil and core tube.

The DIN, Deutsch and lead wire coils versions of the wash-down option uses silicone sealant to help seal between the coil and core tube.

DIN CONNECTION

CODE

BOX CONNECTION

CODE

VOLTAGE & FREQ.

[VOLT - HERTZ]

VOLTAGE LIMITS

[MIN - MAX]

RESISTANCE±10%[OHM]

INRUSH CURRENT

[A]

HOLDING CURRENT

[A]

HOLDING POWER

[W]

33 60120 - 60110 - 50

108 - 12699 - 116

9.25

6.20.911.1

4543

34 61240 - 60 220 - 50

216 - 252198 - 231

382.93

0.480.53

4543

NOT AVAILABLE 68120 - 60110 - 50

108 - 13299 - 121

16.43.73.8

0.380.41

2221

42 - 24 V DC 21 - 26 12 2 2 48

44 - 12 V DC 10 - 13 3.2 3.75 3.75 45

- 70 24 V DC 21 - 26 13.1 1.8 1.8 44

- 75 12 V DC 10 - 13 3.3 3.6 3.6 44

Page 11: CONTINENTAL HYDRAULICS  · PDF filevsd05m - solenoid opera ted directional valve s 5505 west 123rd street • savage, mn 55378-1299 / ph: 952.895.6400

[email protected] - WWW.CONTINENTALHYDRAULICS.COM 11

VSD05M - SOLENOID OPERATED DIRECTIONAL VALVES

APPLICATION DATAFLUIDS All pressure drops shown on these data pages are based on 170 SUS fluid viscosity and 0.87 specific gravity. For any other specific gravity (G1) the pressure drop (∆P) will be approx. ∆P1 = ∆P (G1/G). See the chart for other viscosities.

Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type (phosphate esters) use FPM seals (code G). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical department.

Using fluids at temperatures higher than 180 degrees F causes the accelerated degradation of seals as well as degradation of the fluids physical and chemical properties.

From a safety standpoint, temperatures above 130 degrees F are not recommended.

FLUIDVISCOSITIES

Cst 10 14.5 32 36 43 54 65 76 86 108 216 324 400

SUS 60 75 150 170 200 250 300 350 400 500 1000 1500 1900

MULTIPIER 0.77 0.81 0.97 1.00 1.04 1.10 1.15 1.20 1.24 1.31 1.56 1.72 1.83

INSTALLATIONValves with centering and return springs can be mounted in any position without impairing correct operation. Valves with mechanical detent should have horizontal mounting.

Valves are fixed by means of screws or tie rods on a flat surface with planarity and roughness equal to or better than those indicated in the relative symbols. If minimum values are not observed, fluid can easily leak between the valve and support surface.

RANGE TEMPERATURES:

Ambient - 4 to +130 °F -20 to +54 °C

FluidSTD - 4 to +180 °F -20 to +82 °C

CSA - 4 to +150 °F -20 to +66 °C

FLUID VISCOSITYRange 60 -1900 SUS 10 - 400 cSt

Recommended 120 SUS 25 cSt

FLUID CONTAMINATION ISO 4406:1999 Class 20/18/15

SEAL KIT

BOLT KIT

Buna Seal Kit 1015300

Viton Seal Sit 1015301

BD05-175 131110

Page 12: CONTINENTAL HYDRAULICS  · PDF filevsd05m - solenoid opera ted directional valve s 5505 west 123rd street • savage, mn 55378-1299 / ph: 952.895.6400

VSD0

5M -

SOLE

NOID

OPE

RATE

D DI

RECT

IONA

L VAL

VES

FORM NO. 1015299. REV. 09/2013. © 2012 CONTINENTAL HYDRAULICS. ALL RIGHTS RESERVED. PRODUCT SPECIFICATIONS AND APPEARANCE ARE SUBJECT TO CHANGE WITHOUT NOTICE.

ABOUT CONTINENTAL HYDRAULICSRugged, durable, high-performance, ef�cient—the reason Continental Hydraulics’ products are used in some of the most challenging applications across the globe. With a commitment to quality customer

support and innovative engineering, Continental’s pumps, valves, power units, mobile and custom products deliver what the markets demand. Continental has been serving the food production, brick

and block, wood products, automotive and machine tool industries since 1962. Learn how our products survive some of the most harsh environments.

[email protected] WEST 123RD STREET • SAVAGE, MN 55378-1299 / PH: 952.895.6400 / FAX: 952.895.6444 / WWW.CONTINENTALHYDRAULICS.COM