20
January 2003 CA08102001E For more information visit: www.cutler-hammer.eaton.com Contents Operator Interfaces 48-1 48 0480000 Vol. 2, Ref. No. [1133] Operator Interfaces Description Page Product Family Overview Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-2 PanelMate Technology Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-2 Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-2 Operator Stations Micro PanelMate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-3 PanelMate 1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-5 PanelMate Power Pro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-6 PanelMate ePro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-8 PanelMate PC Pro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-9 Configuration Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-10 Connectivity — Utilities, Interfaces & Cables . . . . . . . . . . . . . . . . . . . . . . . . . 48-13 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-19 PanelMate Operator Interface 0480000

Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

CA08102001E For more

Co

-1

Operator Interfaces 48

January 2003Vol. 2, Ref. No. [1133]

ntents

48

0480

000

Op

era

tor

Inte

rfaces

Description Page

Product Family Overview

Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-2

PanelMate Technology Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-2

Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-2

Operator Stations

Micro PanelMate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-3

PanelMate 1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-5

PanelMate Power Pro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-6

PanelMate ePro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-8

PanelMate PC Pro. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-9

Configuration Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-10

Connectivity — Utilities, Interfaces & Cables . . . . . . . . . . . . . . . . . . . . . . . . . 48-13

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-19

PanelMate Operator Interface

information visit: www.cutler-hammer.eaton.com

0480000
Page 2: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

48-2

48

Operator InterfacesProduct Family Overview

PanelMate

For more information visit: www.cutler-hammer.eaton.com

January 2003Vol. 2, Ref. No. [1134]

Product DescriptionMachine builders and manufacturing system designers increasingly recog-nize the benefits of using electronic operator interface devices to replace pushbuttons, lights, gauges and other traditional hardwired devices.

Most choose dedicated operator inter-face systems because they are easy to use, fully integrated and cost effective.

PanelMate: The Industry StandardPanelMate units are flexible, expand-able, cost-effective alternatives to traditional operator control panels. A single PanelMate unit easily replaces panels that once contained numerous pushbuttons, indicator lights, thumb-wheels, message displays and alarm annunciators.

PanelMate Technology Benefits■ Replaces conventional control

panels at less than half the cost.■ Gives operators more information

for better control decisions.■ Standardizes operator stations and

minimizes operator training.■ Saves processor memory by

utilizing Boolean logic and math functions.

■ Reduces hardwiring costs and minimizes installation time.

■ Adds advanced capabilities such as machine diagnostics, troubleshooting, trending and alarms at no additional cost.

■ Automates documentation.■ Meets tight panel space

requirements.

Application DescriptionPanelMate System ComponentsEach PanelMate system requires component selection from three major categories:

■ Operator Stations — The on-line unit or operator interface

■ Configuration Software — PC-based software, used to configure and transfer applications to and from the Operator Station

■ Connectivity — includes optional cables, hardware interfaces and software utilities

PanelMate Systems — How to Specify and Order■ First, select the most appropriate

Operator Station, Display Type and Size, and Operator Input options for the customer’s application.❑ The selection of the Operator Sta-

tion model line is driven by such considerations as the size and complexity of the operator inter-face application, as well as the economic factors of the overall control system.

❑ The Display Type is chosen based on the operator’s needs — text only, text and graphics, color or grayscale. Display Size is selected based on application complexity and the operator’s proximity to the Operator Station.

❑ Operator Input options include either TouchPanel™ (keypad) or touchscreen operator stations (depending on model line). Crite-ria for selection of the best input method include environmental factors (airborne particles, grease, etc.), and application design (numeric input, one-touch con-trol, etc.).

■ Second, select the appropriate con-figuration editing software for the chosen Operator Station. Note: If the customer already has config-uration software, they may only need a software upgrade.

■ Finally, select required connectivity features, such as interface cables, optional high-speed interface cards, and, for some Allen-Bradley driv-ers, licensing enabler utilities. Eaton’s Cutler-Hammer interface cables are ideal for system and application testing. For actual plant floor applications, custom cables are generally required to meet cus-tomers’ requirements for length, environment, termination, etc. Note: In order to specify the proper cabling and other connectivity options, you must know the target PLC or control-ler that the operator station will interface to. Required information may include the PLC brand, Model Number, software/firmware revision level, and hardware/software interface type.

Table 48-1. PanelMate Operator Stations at a Glance Model Description Typical

ApplicationPrice RangeU.S. $

D830 Micro PanelMate 2 x 20 LCD Display, 20 Keys including numeric keypad Small applicationswith Micro PLC

570.

D840 Micro PanelMate 3.0" Graphic LCD Display, 20 Keys including numeric keypad Small to mediumapplications

825.

PanelMate 1000 5.0" Monochrome LCD Display, TouchPanel Small to mediumapplications

1,655.to 1,980.

PanelMate Pro LT 1100 7.4" Grayscale, 7.7" Color DSTN Full VGA, TouchPanel or Touchscreen

Small applications 995.to 1,595.

PanelMate Power Pro 1700 7.4" Grayscale, 7.7" Color Dual-Scan, 8.4" Color TFT Displays,Full VGA, TouchPanel or Touchscreen

Small to medium applications

1,860.to 4,135.

PanelMate Power Pro 3000 10.4" Color TFT Display, Full VGA, TouchPanel or Touchscreen

Medium to large applications

4,965.to 6,310.

PanelMate Power Pro 5000 14" Color TFT Display, Full VGA, TouchPanel or Touchscreen

Medium to large applications,extended visibility

7,240.to 7,995.

PanelMate ePro Display sizes ranging from 7.7" Color DSTN to 18" Color TFT,Touchscreen (Blind nodes also available)

Small to large applications starting at2,600.

PanelMate PC Pro PanelMate PC Runtime Hardware Key and License Large applications, PC applications, OPC connectivity

1,815.

CA08102001E

Page 3: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

CA08102001E For more

-3

48Operator InterfacesOperator Stations

Micro PanelMate

January 2003Vol. 2, Ref. No. [1135]

48

Micro PanelMate

Micro PanelMate Overview

Simplified Machine ControlThe Micro PanelMate series of products offers unsurpassed capabilities in elec-tronic operator interfaces. All are designed for use with Eaton’s Cutler-Hammer D50 and D300 PLCs, and most other brands of PLCs.

Operator Features■ Large, bright Liquid Crystal Displays

(LCD) with LED backlight make these units easy to view.

■ Membrane keypads offer tactile feedback so that operators receive a physical response for sure and accu-rate operation.

■ Navigation keys, definable function keys, selection and enter keys allow operators to easily step through screens to start, run and monitor their equipment.

On-Line Operation■ High/Low limits for data entry fields

eliminate the potential for errone-ous data being allowed into the PLC data table.

■ An 8-bit scaling value converts values coming from the PLC into operator-recognizable data. Values can be displayed in decimal, binary, hex and ASCII.

■ 15 levels of password protection allow for the same pages to be used for both maintenance and operation personnel with access to only the appropriate data.

Simplified ConfigurationThe configuration software offers an easy way to configure the Micro Panel-Mate family of products. Its upward/downward compatibility means you don’t have to re-invent your application as you move up in features of the dif-ferent models. The WYSIWYG (What You See Is What You Get) editing and off-line verification testing of displays work together for effortless integration.

information visit: www.cutler-hammer.eaton.co

Features■ Data Tag Reference Editor allows for

tags to be created or imported from many PLC programming software packages, reducing application development time.

■ Download files from Excel and Word®, and sort, copy, paste, etc. Once the database has been cre-ated, use it for any host driver with simple modifications to references.

■ A resident simulator allows you to “dry-run” your entire application saving you “on-the-floor” debug time. No need to have the Micro PanelMate and PLC tied together. Trigger screens, enter data and try your entire application before down-loading it.

■ A memory usage monitor calculates the total memory consumed by the application after each integrity check. See at a glance the memory available while configuring your application.

■ Fly-by prompting with tool tips as you move your cursor over the icons and a dialogue bar along the bottom of the editor software elimi-nate confusion and make configura-tion simpler.

■ Single piece construction withcaptive mounting studs for panel mounting, and designed for NEMA 4, 4X and 12 installation when prop-erly mounted in a correspondingly-rated enclosure.

■ Micro PanelMate security is pro-vided with assignable four digit combination locks for data access fields.

■ Meet UL, CSA and UL Class I Division 2 Groups A, B, C, D require-ments and CE requirements.

m

Page 4: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

48-4

48

D830 Micro PanelMate

Operator InterfacesOperator Stations

Micro PanelMate

For more information visit: www.cutler-hammer.eaton.com

January 2003Vol. 2, Ref. No. [1136]

D830 Micro PanelMate

Product DescriptionWith the capability to view and edit PLC data on the same page, define pushbuttons and selector switches per page, and display two pages simultaneously, the D830 changes the definition of a text-based product.

Features■ The 2 line x 20 character display

provides operator information. Messages can scroll both vertically and horizontally to provide up to 255 characters of information, without changing screens.

■ Four function keys (F1, F2, YES, NO) are re-definable on each page and can be configured as momentary pushbuttons, maintained selector switches, exclusive selector switches or page triggers. Two definable nav-igation keys (PREV/NEXT) allow for simple “Step Through” operation.

■ The 10-digit keypad along with ENTER, SELECT, LOCK and CANCEL keys makes changing production variables simple.

■ Meets UL, CSA, CE and UL Class I Division 2 Groups A, B, C D requirements.

Technical Data

Specifications■ Display Type: Liquid crystal display

with LED backlight■ Resolution: 2 x 20 character resolution,

5.5 mm characters■ Number of Simultaneous Trigger

Pages: 2■ Operator Entry

❑ Membrane keypad ❑ 4 navigation❑ 2 definable function keys❑ ENTER, SELECTION, LOCK,

CANCEL

■ Mounting: Single piece construction with captive mounting studs

■ NEMA Rating: NEMA 4, 4X, 12 Note: When properly mounted in a correspondingly rated enclosure.

■ Connections: 25 pin D-shell port for connection to PLCs

■ Power Supply❑ Voltage: 24V DC❑ Consumption: 100 mA

■ Dimensions in Inches (mm): 5.03 H x 7.98 W x 1.41 D (127.8 x 202.7 x 35.8)

■ Ship Wt.: 1.5 lbs (.68 kg)

Product SelectionTable 48-2. D830 Micro PanelMate

D840 Micro PanelMate

Product DescriptionThe D840 Micro PanelMate is a highly functional graphical interface at a price associated with text-based units. Push-buttons and selector switches can be assigned custom bitmap images so operators can respond quicker than to text commands. The D840 supports multiple font sizes, dynamic graphics, recipes, and up to 8 variables simultaneously.

Features■ The 128 x 64 display has the capability

to display bitmap images such as pushbuttons and switches to enhance operator understanding and response.

■ Like the D830, the tactile membrane keypad, navigation, re-definable function, and command keys allow operators a simple way to step through changing production variables.

■ Meets UL, CSA, CE and UL Class I Division 2 Groups A, B, C, D requirements.

Technical Data

Specifications■ Display Type: Liquid crystal display

with LED backlight■ Display Size: 1-3/8 x 2-1/4 inch

(34.9 x 57.2 mm)■ Resolution: 128 x 64 pixel, text and

graphics ■ Number of Simultaneous Trigger

Pages: 2■ Operator Entry:

❑ Membrane keypad ❑ 4 navigation❑ 2 definable function keys❑ ENTER, SELECTION, LOCK,

CANCEL

■ Mounting: Single piece construc-tion with captive mounting studs

■ NEMA Rating: NEMA 4, 4X, 12Note: When properly mounted in a corre-spondingly rated enclosure.

■ Connections: 25 pin D-shell port for connection to PLCs

■ Power Supply❑ Voltage: 24V DC❑ Consumption: 150 mA

■ Dimensions in Inches (mm): 5.03 H x 7.98 W x 1.41 D (127.8 x 202.7 x 35.8)

■ Ship Wt.: 1.5 lbs (.68 kg)

Product SelectionTable 48-3. D840 Micro PanelMate

D830 Micro PanelMate

Description CatalogNumber

PriceU.S. $

Base unit withD50/D300 PLC driver

D830MPM 570.

D840 Micro PanelMate

Description CatalogNumber

PriceU.S. $

Base unit withD50/D300 PLC driver

D840MPM 825.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . PM-1

CA08102001E

Page 5: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

CA08102001E For more

-5

48Operator InterfacesOperator Stations

PanelMate 1000

January 2003Vol. 2, Ref. No. [1137]

48

PanelMate 1000

PanelMate 1000

Product DescriptionThe PanelMate 1000 is a cost-efficient, easy-to-integrate alternative to smaller (6+ pilot devices) hardwired operator panels in PLC-based machine control systems.

Control functions such as machine status indication and pushbutton-style control are accomplished using built-in templates displayed on a compact, vivid, backlit screen. Sealed control buttons and fast screen updates simu-late the action and performance of hardwired pushbuttons. Higher level functions such as machine setup, diagnostic indication and alarm annunciation can be configured easily on this intuitive video control panel.

With DOS-based, off-line, “fill-in-the-blank” configuration software, the PanelMate Series 1000 greatly reduces machine design, assembly and modifi-cation time compared to hardwired operator control panels. The Panel-Mate 1000 is compatible with many brands of PLCs and intelligent control devices.

The PanelMate 1000 is designed for NEMA 4 and NEMA 12 panel-mount installations. Stainless steel front pan-els are available for NEMA 4X installa-tions.

FeaturesApplication flexibility is provided in hardware features that include:

■ Packaging designed for NEMA 4/12 installation

■ Nonvolatile Flash memory■ RS-232C/RS-422 Serial Port for PLC

communications■ Available direct connection to Allen-

Bradley Remote I/O, Data Highway™ and Data Highway Plus

■ Built-in annunciator for control but-ton actuation and alarm conditions

■ System diagnostics■ 5" diagonal backlit monochrome

Liquid Crystal Display (LCD)■ Meets UL, CSA and CE requirements■ 320 x 240 pixels resolution■ 7.8 H x 9.0 W x 1.8 D inches

(198 x 229 x 46 mm)■ 4 redefinable membrane control

buttons, TouchPanel, cancel key and numeric keypad

■ Connector for optional AcceleratI/On™ Interface

Software Features■ 8-page capacity■ 20-alarm summary capacity■ 100-message capacity

Product SelectionThe PanelMate 1000 video control panel is an LCD-based (Liquid Crystal Display), 8-page video control panel.

Table 48-4. PanelMate 1000 Video Control PanelsDescription Catalog

NumberPriceU.S. $

5" Backlit LCD Display8 Page, Monochrome Painted8 Page, Monochrome Stainless

1218218S

1,655.1,980.

Accessories . . . . . . . . . . . . . . . . . . . . . . . Page 48-19Discount Symbol . . . . . . . . . . . . . . . . . . . PM-1

information visit: www.cutler-hammer.eaton.com

Page 6: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

48-6

48

Operator InterfacesOperator Stations

PanelMate Power Pro

For more information visit: www.cutler-hammer.eaton.com

January 2003Vol. 2, Ref. No. [1138]

PanelMate Power Pro

PanelMate Power Pro OverviewThe PanelMate Power Pro operator stations are a cost-efficient, easy-to-integrate alternative to traditional hard-wired operator panels in control systems. The PanelMate Power Pro products pack the latest advanced-technology operator interface func-tionality into a unique, versatile line of flatpanel designs.

The PanelMate Power Pro products have the same cutout and stud pattern as earlier mode PanelMate products and offer increased capabilities.

Control functions, such as machine status indication and pushbutton-style control, are accomplished using built-in templates displayed on a vivid screen. The PanelMate Power Pro simulates the action and performance of hard-wired pushbuttons using sealed, recessed membrane control buttons on the TouchPanel version or on-screen buttons on the touchscreen version. The proven intuitive operation remains the same in all PanelMate products.

Operators select templates or exclusive PowerGraphics™ by moving a finger around the TouchPanel or touchscreen. After selecting a template, the operator performs control actions by pressing control buttons. New functionality also allows users to navigate and initiate control action with just one touch (touch-screen only), if such functionality is configured for the unit using the Panel-Mate Power Pro Windows-based configuration software.

Simplified Machine Control■ Higher level functions such as

machine setup, diagnostics, alarming, trending and custom graphics can be configured easily using the Panel-Mate Power Pro configuration soft-ware. This intuitive software significantly reduces the time and effort needed to create your applica-tion. The software also provides complete compatibility of configura-tion files with other PanelMate Series products (Version 2.1 or later).

■ For realistic representations of machines and processes, the Power-Graphics delivers detailed pixel graphics capability in the full palette of 256 VGA colors. These object-based graphics systems provide scalable multi-layer images, Power-Blink™ eight-state blinking and Power Animation™ for fast operator recognition of dynamic machine characteristics.

■ Application flexibility is provided by hardware features that include: ❑ Approved for use in Type 4, 4X

and 12 installations when properly mounted in a correspondingly rated enclosure. Stainless steel models available for PanelMate Power Pro 3000 and 5000 series.

❑ Executive firmware stored in non-volatile flash memory for easy upgrades.

❑ Battery-backed clock that can be synchronized externally.

❑ Two RS-232/RS-422 serial ports for communications or printing alarms and messages (except PM 1100 Models).

❑ Optional, high-speed, network interface boards for connectivity to a variety of networks.

❑ System diagnostics.❑ All PanelMate Power Pro systems

meet UL, CSA, CE requirements and UL/CSA Class I Division 2 Groups A, B, C, D requirements.

❑ All PanelMate Power Pro models have up to 100-page, 5000-message capacity.

❑ PanelMate Pro LT supports up to 64 I/O references (expandable up to 512 I/O points) and a single communication driver.

■ Display features on all units provide VGA (640 x 480) resolution with:❑ 256-level grayscale on the gray-

scale versions or 256-color palette on color versions.

■ TouchPanel for all models include a display with electronics module and membrane keypad with off-screen 3 x 5 cell control selection, cancel key and numeric entry keypad, with 4 redefinable membrane control buttons to the right of the display. The PanelMate 5000 units have five membrane control buttons.

■ Touchscreen for all models include a display with electronics module and on-screen 3 x 5 cell control selec-tion, 4 redefinable on-screen control buttons, on-screen cancel key and non-intrusive, pop-up, on-screen numeric keypad. The PanelMate 5000 units have five on-screen con-trol buttons.

Displays Available■ 7.4-inch grayscale LCD Flatpanel

(PM Pro LT 1100, PMPP 1700)■ 7.7-inch color DSTN Flatpanel (PM

Pro LT 1100, PMPP 1700)■ 8.4-inch color TFT Flatpanel

(PMPP 1700)■ 10.4-inch color TFT Flatpanel

(PMPP 3000)■ 14-inch color TFT Flatpanel

(PMPP 5000)■ Split Architecture 14-inch color TFT

Flatpanel (PMPP 5000)■ All models available in touchscreen

and TouchPanel

CA08102001E

Page 7: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

CA08102001E For more

-7

48Operator InterfacesOperator Stations PanelMate Power Pro

January 2003Vol. 2, Ref. No. [1139]

48

PanelMate Pro LT 1100

Product DescriptionThe PanelMate Pro LT 1100 is available with a 7.4-inch gray-scale LCD or 7.7-inch color Dual Scan (DSTN) display with full VGA resolution and 256 shades/colors. Models are available with either touchscreen (acrylic) or TouchPanel for operator input and can be mounted in a 4-inch deep enclosure. The PanelMate Pro LT 1100 supports applications with up to 64 I/O references and a single communication driver. The number of supported I/O references can be upgraded to 512 I/O points (done in blocks of 64 I/O points — see 1100TAG Options). The PanelMate Pro LT 1100 requires 24V DC power input.

Product SelectionTable 48-5. PanelMate Pro LT 1100 Operator Stations

1 Discount Symbol PM-2.

PanelMate Power Pro 1700 — Flatpanel

Product DescriptionThe PanelMate Power Pro 1700 is available with a 7.4-inch grayscale LCD, 7.7-inch color Dual-Scan (DSTN) or 8.4-inch color TFT display with full VGA resolution and 256 shades/colors. Models are available with either touchscreen (acrylic) or TouchPanel for operator input and can be mounted in a 4-inch deep enclosure. The PanelMate Power Pro models require 24V DC power input.

Product SelectionTable 48-6. PanelMate Power Pro 1700 Operator Stations

PanelMate Power Pro 3000 — Flatpanel

Product DescriptionThe PanelMate Power Pro 3000 is available with a 10.4-inch color TFT display with full VGA resolution and 256 colors. Models are available with either touchscreen (glass or acrylic) or TouchPanel for operator input and with painted steel or stainless steel front panels. These units can be mounted in a 5-inch deep enclosure. The PanelMate Power Pro models require 24V DC power input.

Product SelectionTable 48-7. PanelMate Power Pro 3000 Operator Stations

PanelMate Power Pro 5000 — Flatpanel

Product DescriptionThe PanelMate PowerPro 5000 features a large, easy-to-see 14-inch color TFT display with full VGA resolution and 256 colors. Models are available with a touchscreen (glass) or TouchPanel for operator input and with painted steel or stainless steel. The TouchPanel versions are available with either of two designs — single-piece front panel or the split architecture design. The TouchPanel models can be mounted in a 19-inch rack. The cutout and stud patterns for all models are the same as earlier versions of PanelMate products that featured the 14-inch display, including the PanelMate I/II/III. The PanelMate Power Pro models require 24V DC power input. The PanelMate Power Pro 5000 can also be ordered with an AC power converter mounted on the back.

Product SelectionTable 48-8. PanelMate Power Pro 5000 Operator Stations

Description CatalogNumber

PriceU.S. $

7.4” Grayscale LCD Display 1TouchPanelTouchscreen

1155K1155T

995.995.

7.7” Color DSTN Display1

TouchPanelTouchscreen

1175K1175T

1,595.1,595.

Description CatalogNumber

PriceU.S. $

7.4” Grayscale LCD DisplayTouchPanelTouchscreen

1755K1755T

1,860.1,860.

7.7” Color DSTN DisplayTouchPanelTouchscreen

1775K1775T

2,790.2,790.

8.4” Color TFT DisplayTouchPanelTouchscreen

1785K1785T

4,135.4,135.

Description CatalogNumber

PriceU.S. $

10.4" Color TFT TouchPanel Painted TouchPanel Stainless Touchscreen Painted, glass Touchscreen Stainless, glass Touchscreen Painted, acrylic Touchscreen Stainless, acrylic

3985K3985SK3985T3985ST3985AT3985SAT

4,965.5,900.4,965.5,900.5,380.6,310.

Description CatalogNumber

PriceU.S. $

14" Color TFT, Single Piece Front PanelTouchPanel PaintedTouchPanel Stainless SteelTouchPanel Painted with AC Power ConverterTouchscreen PaintedTouchPanel Stainless SteelTouchscreen Painted with AC Power Converter

5585K5585SK5585K-AC5585T5585ST5585T-AC

7,240.7,995.7,460.7,240.7,995.7,460.

14" Color TFT, Split Architecture DesignTouchPanel PaintedTouchPanel Stainless SteelTouchPanel Painted with AC Power Converter

5285K5285SK5285K-AC

7,240.7,995.7,460.

Accessories . . . . . . . . . . . . . . . Pages 48-19 – 48-20Discount Symbol . . . . . . . . . . . PM-1

information visit: www.cutler-hammer.eaton.com

Page 8: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

48-8

48

Operator InterfacesOperator Stations

PanelMate ePro

For more information visit: www.cutler-hammer.eaton.com

January 2003Vol. 2, Ref. No. [1140]

PanelMate ePro

Product DescriptionThe PanelMate ePro combines the best features of the PanelMate operator interface and open platform comput-ing to create a very powerful operator interface solution. The PanelMate ePro is designed to meet the growing use of open networks, such as Ethernet, to communicate and share data on the factory floor.

All ePro models are available in three versions. The standard version features PanelMate PC Pro operator interface software. The Extended Edition (XE) includes everything in the standard version with additional pre-loaded application software featuring recipe management, message displaying, trend viewing and document viewing. The Special Edition (SE) supports the same applications provided in the Extended Edition, only the software is not preloaded so customers can load their required versions of Eaton’s Cutler-Hammer ePro software.

Features■ On-board Ethernet■ Client support for OPC/DDE■ Support for optional OPC servers

(over 40 available)■ Can communicate with up to 32

devices■ Can run on up to 32 simultaneous

networks■ Comes equipped with one ISA slot

for high speed interface cards■ Uses flash memory (no rotating

media)■ Provides instantaneous shutdown■ Configured using the same configu-

ration software as PanelMate Power Series and Power Pro products

■ Supports existing PanelMate Power Pro and Power Series applications

■ Supports 200 pages of display information

■ Supports unlimited I/O references■ Supports 65,000 local messages■ Integrates easily with PLC tag files■ Provides one-touch pushbuttons for

non-critical operations and two-touch pushbuttons (select and activate) for critical operations

■ Provides multiple software pass-word protection

■ Comes with many display size and type options including a blind node (no display)

■ Full VGA resolution (640 x 480), 256 colors

Standards and Certifications■ CE■ UL/cUL and CSA Hazardous Locations,

Class I, Div. 2, Groups A, B, C, D ■ Emissions — CISPR 22 Class A —

Radiated and Conducted ■ Noise Immunity: IED 801-2, 3, 4, 6, 8

and IEC 61000-4-2, 3, 4, 5, 6, 8

Technical Data■ Voltage 24V DC, -15%/+20%■ Approved for Type 4, 4X and 12

installations when properly mounted in a correspondingly rated enclosure

Product SelectionTable 48-9. PanelMate ePro Operator Stations

1 10.4" and 18.1" color TFT displays available from Cutler-Hammer.2 Contact factory.

Note: Contact your sales representative for updates on new product offerings and additional technical data details.

Description CatalogNumber

PriceU.S. $

PanelMate ePro 7.7" Color DSTN DisplayExtended EditionSpecial Edition

7575T-87575T-8XE7575T-8SE

2,850.3,850.

2

PanelMate ePro 8.4" Color TFT DisplayExtended EditionSpecial Edition

7585T-87585T-8XE7585T-8SE

4,195.5,195.

2

PanelMate ePro 10.4" Color TFT DisplayExtended EditionSpecial Edition

7585T-107585T-10XE7585T-10SE

5,025.6,025.

2

PanelMate ePro Blind Node (no display1)Extended EditionSpecial Edition

75007500XE7500SE

2,600.3,600.

2

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . PM-1

CA08102001E

Page 9: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

CA08102001E For more

-9

48Operator InterfacesOperator Stations PanelMate PC Pro

January 2003Vol. 2, Ref. No. [1141]

48

PanelMate PC Pro

Product DescriptionPanelMate PC Pro is an on-line version of the PanelMate Power Pro executive software and communication drivers, designed to run on an industry-standard Intel-based personal computer and the Windows NT 4.0 operating system. PanelMate PC Pro is a full 32-bit, Win-dows NT-compliant software package with 32-bit Windows NT PLC drivers, created to take advantage of standard, open architecture hardware and soft-ware developed by other vendors, while maintaining the PanelMate’s leg-endary simplicity and ease of use.

PanelMate PC Pro and Industrial PCPanelMate PC Pro software can be installed on any PC running Windows NT 4.0 or greater which meets the fol-lowing minimum requirements:

■ Intel Pentium 133 MHz (200 MHz recommended)

■ 32 MB DRAM (64 MB recommended)■ 1GB Hard Drive ■ VGA controller and monitor ■ Pointing Device (touchscreen

preferred)■ Windows NT Workstation V 4.0

Benefits■ PanelMate PC Pro allows the user to

tap into the valuable data in Panel-Mate from other PC applications because PanelMate PC Pro is open — Bring data from the plant level down to PanelMate, or feed data from PanelMate PC Pro to other information systems in the plant.

■ PanelMate PC Pro adheres to Win-dows standards and is 100% Win-

dows compatible, allowing you to use the extensive networking capa-bilities of Windows NT.

■ Use of an open hardware/software platform allows the customer to precisely meet their ever-changing needs with easy processor or capac-ity upgrades, using off-the-shelf hardware. Supplemental functionality can be added using off-the-shelf software, allowing the user to incor-porate control, operator interface, analysis, reporting, communications, etc., into one workstation.

■ Use an efficient, Dynamic Link Library (DLL) interface to connect the tried-and-true PanelMate operator interface with Steeplechase’s popular Visual Logic Controller soft logic PC control package.

■ PanelMate PC Pro has the same func-tionality as the PanelMate Power Pro and is fully compatible with applica-tions created for PanelMate Power Series/PanelMate Power Pro prod-ucts. Any Power Series/Power Pro application will run on PanelMate PC Pro.

Note: When purchasing a PanelMate ePro Operator Interface, PanelMate PC Pro is already integrated and ready to run.

Product Selection Table 48-10. PanelMate PC Pro Runtime Hardware Key and License

Note: Runtime software is included with PanelMate Configuration Software #PMPROSW and #PMPROSWSL.

Description CatalogNumber

PriceU.S. $

Runtime Hardware Key to Enable PanelMate PC Pro Runtime SoftwareKey connects to the PC parallel port and has pass-through capabilities. The hardware key is required for PanelMate on-line operation.

PMPC-RT 1,815.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . PM-1

information visit: www.cutler-hammer.eaton.com

Page 10: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

48-10

48

Operator InterfacesConfiguration Software

PanelMate

For more information visit: www.cutler-hammer.eaton.com

January 2003Vol. 2, Ref. No. [1142]

Micro PanelMate Configuration Software

Product DescriptionWhen installed on a Windows-based PC, this software permits access to all configuration operations. The easy, fill-in-the-blanks software provides WYSIWYG (What You See Is What You Get) creation of pages. In addition, you can down-load pages and PLC communication interfaces, options and completed pages from your personal computer.

A minimum 386-based personal computer with VGA graphics, 4 MB RAM and Windows 3.1 or higher is required to run the configuration software. Twenty megabytes of free hard disk space is required to load the configuration software with all the PLC communication interfaces and to configure a typical configuration. To fully view configurations, 256 colors are needed. Software is supplied on 3-1/2" high density diskettes.

Note: Configuration software can be installed and used on one or more personal computers or on a shared access computer network, so long as all use takes place at no more than one (1) site at any time.

Configuration software can be used to configure an unlim-ited number of PanelMate units. You only need to buy one package for each series you are using. RS-485/RS-232 Adapter is needed (#D50CPM485).

Product SelectionTable 48-11. Windows Configuration Software for Micro PanelMate

Communication Enable Utility for Micro PanelMate

Table 48-12. Communication Enable Utility

Note: See D800ENABLEDH on Page 48-14 for DH-485 communications.

PanelMate 1000 Configuration Software

Features■ PC-based configuration editor■ Password protection■ International character set support■ Page selection by operator and/or PLC■ System diagnostics■ User-definable on-line system prompts to permit non-

English or customized text■ Alarm summary page

Standard Fixed Size Templates■ Indicator Templates■ Readout Templates■ Bar Templates■ Display Templates■ Table Templates■ Maintenance Templates

PLC Communication InterfacesCommunication interfaces for the following programmable controllers:

■ Allen-Bradley PLC-2, PLC-3, PLC-5 and SLC-500■ Eaton’s Cutler-Hammer D200, D500■ GE Fanuc Series 5, Series 6, Series 6+ and Series 90■ Mitsubishi “A” Series and “FX” Series■ Modicon Modbus ASCII/RTU■ Omron “C” Series plus CV500, CV1000■ Reliance AutoMate■ Siemens S5 Series, 3964R Protocol■ Simatic TI 305/405 and 500/505 Series■ Square D SyMax■ Westinghouse NumaLogic

AcceleratI/On High-Speed Direct Connectivity Available■ Allen-Bradley Data Highway and Data Highway Plus■ Allen-Bradley Remote I/O Link

When installed on a DOS-based PC, this software permits “WYSIWYG” (What You See Is What You Get) page creation on your PC. The easy fill-in-the-blank approach permits link-ing pages to the PLC and downloading a PLC driver, options and completed pages to the PanelMate 1000 on-line unit.

Product SelectionTable 48-13. Configuration Software for PanelMate Series 1000

Description CatalogNumber

PriceU.S. $

Windows Configuration Software with Communication Software Interfaces for all major PLCs:AB SLC 500 DH-485, PLC-5 DF1, SLC-5/03, 5/04 DF1AB Micrologix DF1GE 90 Series with SNP ProtocolMitsubishi FX SeriesModicon Modbus RTUOmron Host LinkSiemens S5 SeriesEaton’s Cutler-Hammer D50, D300ASCII CommunicationsIncluded in package:D800CBLXFRD800DWNLDD800ENABLEManuals

D800CCSSET 409.

Description CatalogNumber

PriceU.S. $

Micro PanelMateRequired for each individual D830, D840 or D850 that will use any non-Cutler-Hammer PLC commu-nications interface other than DH-485.

D800ENABLE 52.Description Catalog

NumberPriceU.S. $

PanelMate Series 1000 DOS-Based Configuration Software and manual with Communication Software Interfaces for all major PLCs and High Speed Industrial NetworksSupport for AB, CH, GE, MB, MI, OM, RE, SD, SI, TI, WE. Permits the installation and use of the Software on one or more computers or in a shared access computer network, so long as all use takes place at no more than one (1) site at any time.

1220 515.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . PM-1

CA08102001E

Page 11: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

CA08102001E For more

11

48-Operator InterfacesConfiguration Software PanelMate

January 2003Vol. 2, Ref. No. [1143]

48

PanelMate Power Pro, PanelMate Power Series,PanelMate PC Pro and PanelMate ePro Configuration Software

Application DescriptionWindows-based configuration software is used to create PanelMate Power Series/PanelMate Power Pro configu-rations off-line on a PC. It also permits the editing of character-based configu-rations from earlier-version Panel-Mate Series products. The following items can be configured:

■ One-touch control (for touchscreen models)

■ PowerGraphics■ PowerAnimation■ 8-state PowerBlink (for 256-level/color

models)■ 3-level Password protection■ International character set support■ Page change by operators and/or

PLC■ User-definable on-line system

prompts to permit non-English or customized text that can be toggled with standard on-line prompts by operators

■ Alarm window with a 100-alarm capacity

Features■ Indicator Templates ■ Readout Templates ■ Bar Templates ■ Display Templates ■ Trend Templates ■ Table Templates ■ Variable-Size Control Button

Templates ■ Pop-Up Maintenance Window ■ Alarm Window■ Advanced Trend Templates ■ Tag Name File Support ■ Expression Management ■ 3000 Symbol Factory Clip Art

PLC Communication InterfacesCommunication interfaces are avail-able for the following programmable controllers and are downloaded from the configuration software.

Note: Multiple interfaces may be run simul-taneously on PanelMate Power Pro 1700, 2000, 3000, 4000 and 5000 units.

■ Allen-Bradley PLC-2, PLC-3, PLC-5 and SLC-500

■ Eaton’s Cutler-Hammer D50, D300, D320

■ GE Fanuc Series 5, 6, 90■ Mitsubishi “A” Series and “FX”

Series■ Modicon Modbus ASCII/RTU■ OMRON “C” Series plus CV500,

CV1000

■ PLC-Direct DL 405 Family■ Square D SyMax■ Siemens S5 Series, 3964R Protocol,

AS511■ Simatic TI 305/405 and 500/505

Series■ Reliance Automate■ Toshiba T2

High Speed Direct Connectivity Available■ Allen-Bradley Data Highway and

Data Highway Plus■ Allen-Bradley Remote I/O Link■ GE Fanuc GEnius I/O Network■ DeviceNet■ Modicon Modbus Plus■ PROFIBUS

Transfer CablesPanelMate configuration software packages #PMPROSW and #PMPROSWSL include a PanelMate 1100, 1700, 2000, 3000, 4000, 5000 (#0518) Transfer Serial Cable.

Product SelectionTable 48-14. Windows Configuration Software for PanelMate Power Pro, PanelMate Power Series, PanelMate PC Pro and PanelMate ePro

Automation Update Service MembershipAll purchases of PanelMate Power Pro software qualify you for product announce-ments and free service releases from the Automation Update Service when you register using the forms included in the software packages.

Description CatalogNumber

PriceU.S. $

PanelMate Power Pro Windows Configuration Software and Manuals with Communication Software Interfaces for all major PLCs and High Speed Industrial Networks on CD-ROM with Tag and ExpressionManagement and Symbol Factory Clipart. Support for AB, CH, DN, GE, GEIO, MB, MBP, MI, OM, PD, RE, RO, SD, SI, TB, TI. #PMPROSW includes transfer serial cable for PM1700, 2000, 3000, 4000, 5000 (#0518). #PMPROSW includes electronic copies of manuals in .PDF format and a hard copy of the Getting Started manual. Seat license.

PMPROSW 515.

Site License — See PMPROSW PMPROSWSL 1,550.PanelMate Power Pro Upgrade from previous PanelMate Power Series Software to PanelMate Power Pro software version on CD-ROM. Requires earlier version of PanelMate Power Series software for installation.

PMPROSWUP 140.

PanelMate Power Pro Software Upgrade — Site LicenseRequires previous installation of PanelMate Power Pro Software Site License (PMPROSWSL). On CD-ROM.

PMPROSWSLUP 409.

PanelMate Power Pro Hardcopy documentation set. Electronic copies of these manuals are included on the CD of #PMPROSW and #PMPROSWUP.

PMPROMANUAL 363.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . PM-1

information visit: www.cutler-hammer.eaton.com

Page 12: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

48-12

48

Operator InterfacesConfiguration Software

PanelMate

For more information visit: www.cutler-hammer.eaton.com

January 2003Vol. 2, Ref. No. [1144]

PanelMate ePro and PanelMate PC Pro CommunicationsThe PanelMate ePro and PanelMate PC Pro (Catalog Number PMPC-RT) can communicate with a myriad of PLCs and hardware platforms using many different protocols and network strategies. In order to provide these connectivity solutions, the following communications are supported.

OLE for Process Control (OPC)PanelMate ePro and PanelMate PC Pro include OPC client support. This means that OPC servers can be used to pro-vide connectivity solutions for many different types of com-munication protocols. OPC provides a fast, precise, economic and efficient solution to communication needs. Eaton’s Cutler-Hammer has formed a partnership with Kepware, the leading supplier of OPC connectivity solutions, so that the following OPC servers are available to be used with the PanelMate ePro and PanelMate PC Pro.

Table 48-15. OPC Servers

Also, by using the OPC client/server strategy and special hardware the PanelMate ePro and PanelMate PC Pro can connect to a variety of high-speed networks. Authorized con-nectivity solutions are available from SST and Square D.

■ SST ControlNet Interface Card and OPC Server —5136-CN ISA

■ SST Profibus DP Interface Card and OPC Server —5136-PBMS ISA

■ Square D Modbus Plus SA-85 Interface Card — SA-85-300 ISA (OPC server purchased separately — see KEPMBP OPC server in Table 48-15).

Note: For communications using Allen-Bradley’s Data Highway Plus protocol, customers can purchase an ISA interface board from Eaton’s Cutler-Hammer (Catalog Number D712-DHP-ISA). The com-munication driver used with the board is provided with the Panel-Mate Configuration Software.

Dynamic Data Exchange (DDE)Using the Microsoft standard DDE interface, PanelMate PC Pro data can be easily and efficiently shared with any other applications that support DDE, such as Microsoft Excel, Microsoft Access, Visual Basic and Visual C++. PanelMate PC Pro’s built-in DDE connectivity provides simple integration with other applications for report generation, recipe man-agement, machine setup, data analysis and archiving.

Supplied DriversThe PanelMate Configuration Software (PMPROSW) includes communication support for many different commu-nication protocols and strategies. The following drivers are available for use with PanelMate ePro and PanelMate PC Pro.

Table 48-16. Available Drivers

Note that the PanelMate ePro supports RS-232 communica-tions only. A converter is required for RS-422 and RS-485 communications.

Description CatalogNumber

PriceU.S. $

Kepware OPC Servers for Allen-Bradley- Ethernet for PLC5, SLC505- ControlLogix Ethernet- PLC5, SLC500, MicroLogix DF1 Serial

KEPABSUITE 795.

OPC Server for Analog DevicesOPC Server for AromatOPC Server for Bailey/Fischer & Porter Micro-DCI

KEPANDKEPAROKEPMDC

795.795.795.

OPC Server for ContrexOPC Server for Contrex M-SeriesOPC Server for Cutler-Hammer D50/320/32LT

KEPCTXKEPCTMKEPCHD

795.795.795.

Kepware OPC Servers for GE Fanuc- Ethernet 90-30/90-70- Ethernet Global 90-30/90-70/EGD- SNP Serial- SNPX Serial- CCM Serial

KEPGESUITE 795.

OPC Server for IdecOPC Server for Intelligent Actuator Super SEL(Type E & G)

OPC Server for Koyo DirectOPC Server for Koyo K SequenceOPC Server for Mitsubishi A SeriesOPC Server for Mitsubishi FXOPC Server for Mitsubishi FX Net

KEPIDEKEPIAS

KEPKDNKEPKKSKEPMTAKEPMFXKEPMFN

795.795.

795.795.795.795.795.

Kepware OPC Servers for Modicon- Modbus OPEN Ethernet TCP/IP- Modbus Plus (requires SA-85 card from Square D)

- Modbus ASCII Serial- Modbus RTU Serial- Modbus RTU Slave Serial

KEPMODSUITE 795.

Kepware OPC Servers for Omron- Host Link Serial- Process Suite Serial- FINS Ethernet- FINS Serial

KEPOMSUITE 795.

OPC Server for Optimation OptiLogicOPC Server for Partlow ASCIIOPC Server for PLC Direct (Koyo) EBC EthernetOPC Server for PLC Direct (Koyo) ECOM EthernetOPC Server for Siemens S5 AS511

KEPOOPKEPPAAKEPKEEKEPKECKEPSS5

795.795.795.795.795.

OPC Server for S7-200 PPIOPC Server for Simatic 505OPC Server for Simatic 505 EthernetOPC Server for Square D SY/MAXOPC Server for TIWAY Host Adapter

KEPSS7KEPSI5KEPS5EKEPSQDKEPTIW

795.795.795.795.795.

OPC Server for Toshiba ASCII Computer LinkOPC Server for Toyopuc SerialOPC Server for Telemecanique Uni-TelwayOPC Server for Yokogawa DarwinOPC Server for Yokogawa DX

KEPTOSKEPTPSKEPTELKEPYODKEPYDX

795.795.795.795.795.

Driver Type Communication Type for Controller from Supplier

Allen-Bradley DH+ Requires Communication Board Catalog Number D712-DHP-ISA

Allen-Bradley DH 485 RS-232 by using A-B KF3 module

Allen-Bradley DF1 Serial RS-232, RS-422

Cutler-Hammer D50/D300 RS-422, RS-485

GE Master/Slave RS-232, RS-422

GE Peer to Peer RS-232, RS-422

GE Series 90 Network RS-422

GE Series 90 Point to Point RS-422

Modicon ASCII RS-232

Omron RS-232, RS-422

Reliance RS-232

Siemens S7 RS-232

Steeplechase VLC (Netsolver) DLL

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . PM-1

CA08102001E

Page 13: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

CA08102001E For more

13

48-Operator InterfacesConnectivity PanelMate — Utilities, Interfaces & Cables

January 2003Vol. 2, Ref. No. [1145]

48

Communication Utilities

Transfer Serial CableOne 6-foot, RS-232 cable with DB9 connectors on each end, for upload/download between standard serial PC communica-tion port and PanelMate serial port. Adapter for converting DB9 connector to a DB25 connector is also included.

Table 48-17. Transfer Serial Cable 1

1 Transfer serial cables for 1100, 1700, 2000, 3000, 4000 and 5000 are included in configuration software package #PMPROSW and #PMPROSWSL (includes #0518).

Transfer UtilityWindows utility allowing configuration, options and com-munication interfaces to be uploaded and downloaded between a PC and a unit, but does not permit configuration. Users can transfer configurations while the originator main-tains central control and protection against alterations.

Note: All PanelMate Configuration Software packages include a transfer utility as an integral part of the software. This is a separate utility for OEMs and others that do not want to give configuration or change capability to the person using this utility.

Table 48-18. Transfer Utility

On-Line Printing for PanelMate Series 500“One-time use” diskette. Enables RS-232 serial port #2 of the PanelMate 500 to transmit on-line alarm messages to a printer creating hard copy documentation of alarms. For Series 500 Models #542L, #542V, #542LM and #542VM.

Table 48-19. On-Line Printing

Converter Cables for PanelMate 500 and PanelMate Power Series 1500Cable that allows the conversion from a 9-pin D-Shell connector to a RJ11 or RJ45 phone jack-style connector.

Table 48-20. Converter Cables

Cable Making Kit for PanelMate 500 and PanelMate Power Series 1500Kit includes 10 RJ11 and 10 RJ45 connectors, 5 Phoenix plugs and 100 ft. (30m) of cable for making as many as 10 PLC communications cables. Also includes a crimping tool for attaching RJ11/RJ45 connectors to the cable.

Table 48-21. Cable Making Kits

Driver Memory Expansion KitIncludes option memory module, installation disk and elec-trostatic protection. The kit enables more than one PLC communication interface to run simultaneously in the target Power Series on-line unit.

Table 48-22. Driver Memory Expansion Kit

Note: Not required for PanelMate Power Pro 1700, 3000 or 5000.

Description CatalogNumber

PriceU.S. $

For Micro PanelMate(Included in D800CCSSET software packages)

D800CBLXFR 83.

PanelMate 500, 1500 0818 83.

1000, 1700, 2000, 3000, 4000, 5000 Additional 0518 83.

Description CatalogNumber

PriceU.S. $

For Micro PanelMate D800XFR 104.

PanelMate Power Series/PanelMate Power Pro and PanelMate 500

0621 104.

PanelMate 1000 (DOS Utility) 1221 104.

Description CatalogNumber

PriceU.S. $

For PanelMate 500(For Models 542L, 542LM, 542V, 542VM only)

0811 104.

Description CatalogNumber

PriceU.S. $

RS-485/422 from DB9(M) to RJ45(M)(1 foot/.3m)

0819 83.

RS-232 from DB9(M) to RJ11(M) (1 foot/.3m) 0820 83.

RS-232 from RJ11(M) to DB9(M) 0821 83.

Description CatalogNumber

PriceU.S. $

For PanelMate 500 and PanelMate Power Series 1500

1512 409.

Description CatalogNumber

PriceU.S. $

For PanelMate Power Series 2000, 3000, 4000, 5000

Required to run more than one PLC driver simultaneously in a target on-line unit.

0721 270.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . PM-1

information visit: www.cutler-hammer.eaton.com

Page 14: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

48-14

48

Operator InterfacesConnectivity

PanelMate — Utilities, Interfaces & Cables

For more information visit: www.cutler-hammer.eaton.com

January 2003Vol. 2, Ref. No. [1146]

Allen-Bradley Connectivity

Remote I/O, Data Highway, Data Highway Plus

Accelerate/On InterfaceLicensed under A-B patented technology, the interface provides a communication port for connecting directly to the user’s choice of Allen-Bradley PLC networks: Remote I/O Link, Data Highway or Data Highway Plus. Can be used simultaneously with PanelMate 1700, 2000, 3000, 4000 and 5000 serial ports.

Table 48-23. Remote I/O, Data Highway, Data Highway Plus

Note: Includes royalty for license under Allen-Bradley patented technology.

Allen-Bradley PLC Network Upload/Download“One-time use” diskette enables the PanelMate unit to upload and download PanelMate configurations to PCs via Allen-Bradley PLC networks. This Upload/Download feature can be used to conduct the following operations without having to disconnect the PanelMate Unit from the PLC, or open the enclosure to access the serial ports:

■ Download configurations from a PC in a central location to PanelMate units on a network.

■ Upload PanelMate configurations (while units are monitoring and controlling) to a PC for backup.

■ Download new PanelMate software enhancements to units. Note: Requires Accelerate/On Interface (#XX41) and WindowsConfiguration Software or Transfer Utility option #0621.

■ Requires A-B RSLinx-OEM version 2.0 or higher or A-B Interchange software.

Table 48-24. Allen-Bradley PLC Network Upload/Download

PanelMate PC Data Highway PlusTable 48-25. Data Highway Plus

Allen-Bradley DH-485 (SLC-500) Communications“One-time use” diskette. Licensed under A-B patented technology, this option enables communications to Allen-Bradley SLC-500 PLCs through the DH-485 network in a single target Power Series on-line unit. A-B 1747-AIC Module is only required when simultaneous interface to PanelMate and PLC programming equipment is desired.

Table 48-26. DH-485

Note: Includes royalty for license under Allen-Bradley patented technology.

Micro PanelMateTable 48-27. Micro PanelMate

Description CatalogNumber

PriceU.S. $

AcceleratI/On™ InterfaceDirect connect to Remote I/O Link, Data Highway or Data Highway PlusPanelMate Power Series 2000PanelMate Power Series 3000, 4000, 5000PanelMate 500, PanelMate 1000, PanelMate 1500 and PanelMate Power Pro 1700

PanelMate Power Pro 3000, 5000

244107411241

1251

1,065.1,065.

640.

1,065.

Description CatalogNumber

PriceU.S. $

One-time use diskette. Enables upload/download on operator station.

0524 327.

Description CatalogNumber

PriceU.S. $

ISA 1 Port PanelMate PC Adapter D712-DHP-ISA 1,430.

Description CatalogNumber

PriceU.S. $

Allen-Bradley DH-485 (SLC-500) CommunicationsOne-time use diskettePanelMate Power Series 2000PanelMate Power Series 3000, 4000, 5000 and PanelMate Power Pro 3000, 5000PanelMate 500, PanelMate 1500 and PanelMate Power Pro 1700

24250725

1525

311.311.

114.

PanelMate 1000 1225 114.

Description CatalogNumber

PriceU.S. $

Communications Enable Utilitywith DH-485D800ENABLEDH is required for each D830, D840 or D850 that will use Allen-Bradley SLC500 DH-485 PLC Communications Interface.

D800ENABLEDH 166.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . PM-1

CA08102001E

Page 15: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

CA08102001E For more

15

48-Operator InterfacesConnectivity PanelMate — Utilities, Interfaces & Cables

January 2003Vol. 2, Ref. No. [1147]

48

Allen-Bradley Communication Cables Table 48-28. PLC Interface Cables for Micro PanelMate

PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000 and 5000 and PanelMate Power Pro 1100, 1700, 3000 and 5000One 15-foot (4.6m) cable, unless otherwise stated, for commu-nications between a PanelMate 1100, 1700, 2000, 3000, 4000 or 5000 unit serial port and the PLC communications port using D-Shell connectors.

Table 48-29. PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000 and 5000 and PanelMate Power Pro 1100, 1700, 3000 and 5000

Eaton’s Cutler-Hammer Connectivity

Eaton’s Cutler-Hammer Communication CablesTable 48-30. PLC Interface Cables for Micro PanelMate

PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000, 5000 and PanelMate Power Pro 1100, 1700, 3000, 5000One 15-foot (4.6m) cable, unless otherwise stated, for commu-nications between a PanelMate 1100, 1700, 2000, 3000, 4000 or 5000 unit serial port and the PLC communications port using D-Shell connectors.

Table 48-31. PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000, 5000 and PanelMate Power Pro 1100, 1700, 3000, 5000

DeviceNet ConnectivityThe PanelMate DeviceNet implementation features the ability to “monitor” status from other slave devices without the need for active involvement from the master device. When installed on DeviceNet, PanelMate can update its screens with data from the slave devices or from the PC. It can also input control (pushbutton) operations or numeric informa-tion to the PC. These capabilities permit PanelMate units to function as complete control and monitoring stations on DeviceNet.

DeviceNet Interface for PanelMate PC Pro is via the Steeple-chase Visual Logic Controller (VLC) Software package.

Table 48-32. DeviceNet Interface 1

1 Discount Symbol 3CD-2.

Description CatalogNumber

PriceU.S. $

Allen-Bradley SLC 500 DH-485 PLC CableAllen-Bradley SLC 500 DF1 PLC CableAllen-Bradley PLC-5 DF1 PLC Cable

D800CBLAB1D800CBLAB6D800CBLAB7

83.83.83.

Description CatalogNumber

PriceU.S. $

1785-KE, 1771-KC, KD, KE, KF, KG1770-KF2A, KF2B, 1775-KAAB SLC503/504 (RS-232) Channel 0AB PLC5 (RS-232) Channel 0, DF1

AB21AB22AB25AB26

83.83.83.83.

AB 1747 AIC for SLC 500 (DH-485 INTFC) (Replaces AB23)AB SLC 500 Direct (6 ft./1.8m) Cable (Replaces AB24)AB PLC5 (RS-422) Channel 0, DF1 Cable (Replaces AB27)AB 1747 AIC for SLC 500, CPU Connector (J1) AB Micro Logix Adapter Cable (1 ft./.3m) (DB9F to DB9M)

AB23AAB24AAB27AAB28AAB29

83.83.83.83.83.

Description CatalogNumber

PriceU.S. $

C-H D50/D300 PLC Cable D800CBLCH1 83.

Description CatalogNumber

PriceU.S. $

Eaton’s Cutler-Hammer D200 Cable (Replaces CH21)Eaton’s Cutler-Hammer D50/D150/D300/D320 (RS-485) Cable (Replaces CH22)

CH21ACH22A

83.83.

Description CatalogNumber

PriceU.S. $

For all PanelMate 1500 and PanelMate 500 and PanelMate Power Pro 1700, 3000, 5000

For all Power Series 2000, 3000, 4000, 5000

1245DN

0745DN

730.

730.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . PM-1

information visit: www.cutler-hammer.eaton.com

Page 16: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

48-16

48

Operator InterfacesConnectivity

PanelMate — Utilities, Interfaces & Cables

For more information visit: www.cutler-hammer.eaton.com

January 2003Vol. 2, Ref. No. [1148]

General Electric Connectivity

GE Fanuc GEnius I/O Interface to GE PLCsThis interface provides a communication port for connection to GE Series 6 and Series 90 PLCs over the GEnius I/O Network.

Table 48-33. GEnius I/O Interface

General Electric Communication CablesTable 48-34. PLC Interface Cables for Micro PanelMate

PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000, 5000 and PanelMate Power Pro 1100, 1700, 3000, 5000One 15-foot (4.6m) cable, unless otherwise stated, for commu-nications between a PanelMate 1100, 1700, 2000, 3000, 4000 or 5000 unit serial port and the PLC communications port using D-Shell connectors.

Table 48-35. PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000, 5000 and PanelMate Power Pro 1100, 1700, 3000, 5000

Mitsubishi Connectivity

Mitsubishi Communication CablesTable 48-36. PLC Interface Cables for Micro PanelMate

PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000, 5000 and PanelMate Power Pro 1100, 1700, 3000, 5000One 15-foot (4.6m) cable, unless otherwise stated, for commu-nications between a PanelMate 1100, 1700, 2000, 3000, 4000 or 5000 unit serial port and the PLC communications port using D-Shell connectors.

Table 48-37. PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000, 5000 and PanelMate Power Pro 1100, 1700, 3000, 5000

Description CatalogNumber

PriceU.S. $

GEnius I/O InterfaceFor all PanelMate 1500 and PanelMate Power Pro 1100, 1700, 3000, 5000For all Power Series 2000, 3000, 4000, 5000

1243

0543

1,105.

1,105.

Description CatalogNumber

PriceU.S. $

General Electric Series 90 PLC Cable D800CBLGE2 83.

Description CatalogNumber

PriceU.S. $

Series 90 (RS-422) Com 311/711 ModuleSeries 90 (RS-232) Com 311/711 ModuleSeries 6/6+ (RS-422) Com 2 – J1 PortSeries 6/6+ (RS-232) Com 2 – J2 Port

GE22GE23GE24GE25

83.83.83.83.

Series 90 Programming Port (Replaces GE21) GE21A 83.

Description CatalogNumber

PriceU.S. $

Mitsubishi FX Series PLC Cable D800CBLMI1 83.

Description CatalogNumber

PriceU.S. $

A Series — AJ71C24 Module (RS-232)FX/FXo Series — (RS-232/RS-422) Converter

MI21MI23

83.83.

A Series — AJ71C24 Module (RS-422) Cable (Replaces MI22)

MI22A 83.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . PM-1

CA08102001E

Page 17: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

CA08102001E For more

17

48-Operator InterfacesConnectivity PanelMate — Utilities, Interfaces & Cables

January 2003Vol. 2, Ref. No. [1149]

48

Modicon Connectivity

Modicon Modbus Plus PLC Network Upload/Download“One-time use” diskette enables the PanelMate unit to upload and download PanelMate configurations to PCs via Modicon Modbus Plus PLC networks. This Upload/Down-load feature can be used to conduct the following operations without having to disconnect the PanelMate Unit from the PLC, or open the enclosure to access the serial ports:

■ Download configurations from a PC in a central location to PanelMate units on a network.

■ Upload PanelMate configurations (while units are moni-toring and controlling) to a PC for backup.

■ Download new PanelMate software enhancements to units. Note: Requires Modbus Plus Interface, Configuration Software or Transfer Utility option #0621.

Table 48-38. Modicon Modbus Plus Network Upload/Download

Modbus Plus Communications and PanelMate This interface provides a communication port for connection to Modicon PLCs over the Modbus Plus network. Interface mounts to the back of the on-line unit and can be mounted in a 4-inch (102 mm) deep enclosure.

Table 48-39. Modbus Interface

Modicon Communication CablesTable 48-40. PLC Interface Cables for Micro PanelMate

PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000, 5000 and PanelMate Power Pro 1100, 1700, 3000, 5000One 15-foot (4.6m) cable, unless otherwise stated, for commu-nications between a PanelMate 1100, 1700, 2000, 3000, 4000 or 5000 unit serial port and the PLC communications port using D-Shell connectors.

Table 48-41. PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000, 5000 and PanelMate Power Pro 1100, 1700, 3000, 5000

Omron Connectivity

Omron Communication CablesTable 48-42. PLC Interface Cables for Micro PanelMate

PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000, 5000 and PanelMate Power Pro 1100, 1700, 3000, 5000One 15-foot (4.6m) cable, unless otherwise stated, for commu-nications between a PanelMate1100, 1700, 2000, 3000, 4000 or 5000 unit serial port and the PLC communications port using D-Shell connectors.

Table 48-43. PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000, 5000 and PanelMate Power Pro 1100, 1700, 3000, 5000

PROFIBUS DP Connectivity

PROFIBUS DP InterfaceThis PROFIBUS DP Slave Adapter interface provides com-munications between a PanelMate operator interface and a PROFIBUS network without requiring any additional com-munications modules. A maximum of one interface can be installed on each PanelMate unit.

Table 48-44. PROFIBUS DP Interface

Description CatalogNumber

PriceU.S. $

One-time use diskette. Enables upload/download on operator station. To operate, customer requires:1) Modbus Plus Interface (1248, 0748-1, 0748-2)

to be installed in unit2) Windows Configuration Software OR

Transfer Utility Option #0621 on the PC

0548 327.

Description CatalogNumber

PriceU.S. $

Direct Modbus Plus InterfacePanelMate 500PanelMate Power Series 1500 andPanelMate Power Pro 1700, 3000, 5000

PanelMate Power Series 2000, 3000, 4000, 5000 (single channel)

12441248

0748-1

665.665.

665.

Modicon Modbus PLC Communications DriverPanelMate 1000 (1X use diskette)

1224 166.

Description CatalogNumber

PriceU.S. $

Modicon 9-Pin Modbus PLC Cable D800CBLMB1 83.Modicon Micro PLC Cable D800CBLMB2 83.

Description CatalogNumber

PriceU.S. $

9-Pin Modbus MB21 83.Micro PLC (RJ-45) Modbus Cable MB22 83. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . PM-1

Description CatalogNumber

PriceU.S. $

Omron Host Link PLC Cable D800CBLOM1 83.

Description CatalogNumber

PriceU.S. $

C Series (RS-232)CV Series (RS-232)

OM21OM22

83.83.

C Series (RS-422) Cable (Replaces OM23)CV Series (RS-422) Cable (Replaces OM24)

OM23AOM24A

83.83.

CS/CQ Series (RS-232) Cable OM25 83.

Description CatalogNumber

PriceU.S. $

PROFIBUS DP Slave I/O InterfaceFor all PanelMate Power Series 1500, PanelMate Power Pro 1100, 1700, 3000, 5000

1247 1,030.

For all PanelMate Power Series 2000, 3000, 4000, 5000

0544 1,030.

information visit: www.cutler-hammer.eaton.com

Page 18: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

48-18

48

Operator InterfacesConnectivity

PanelMate — Utilities, Interfaces & Cables

For more information visit: www.cutler-hammer.eaton.com

January 2003Vol. 2, Ref. No. [1150]

Siemens Connectivity

Siemens Communication CablesTable 48-45. PLC Interface Cables for Micro PanelMate

PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000, 5000 and PanelMate Power Pro 1100, 1700, 3000, 5000One 15-foot (4.6m) cable, unless otherwise stated, for commu-nications between a PanelMate 1100, 1700, 2000, 3000, 4000 or 5000 unit serial port and the PLC communications port using D-Shell connectors.

Table 48-46. PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000, 5000 and PanelMate Power Pro 1100, 1700, 3000, 5000

Simatic TI Connectivity

Simatic TI Communication Cables

PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000, 5000 and PanelMate Power Pro 1100, 1700, 3000, 5000One 15-foot (4.6m) cable, unless otherwise stated, for commu-nications between a PanelMate 1100, 1700, 2000, 3000, 4000 or 5000 unit serial port and the PLC communications port using D-Shell connectors.

Table 48-47. PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000, 5000 and PanelMate Power Pro 1100, 1700, 3000, 5000

Square D Connectivity

Square D Communication Cables

PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000, 5000 and PanelMate Power Pro 1100, 1700, 3000, 5000One 15-foot (4.6m) cable, unless otherwise stated, for commu-nications between a PanelMate 1100, 1700, 2000, 3000, 4000 or 5000 unit serial port and the PLC communications port using D-Shell connectors.

Table 48-48. PLC Interface Cables for PanelMate Power Series 2000, 3000, 4000, 5000 and PanelMate Power Pro 1100, 1700, 3000, 5000

Description CatalogNumber

PriceU.S. $

Siemens Semantic SS Series PLC Cable D800CBLSI1 83.

Description CatalogNumber

PriceU.S. $

Siemens (RS-232)Siemens S7 HMI Cable

SI21SI22

83.83.

Description CatalogNumber

PriceU.S. $

TI 500, 305 (RS-232)TI 405 (RS-232)TI 545 (RS-232)

TI21TI22TI23

83.83.83.

TI 435 (RS-422 Cable (Replaces TI24)TI 305-02DM, TI 405 DCM (RS-422) Cable (Replaces TI25)

TI 545-1101 (RS-422) Cable (Replaces TI26)TI 545-12102, 1104, 1105 Cable (Replaces TI27)

TI24ATI25A

TI26ATI27A

83.83.

83.83.

Description CatalogNumber

PriceU.S. $

PLC Processor Cable (Replaces SD21)NIM Network Interface Module Cable (Replaces SD22)

SD21ASD22A

83.83.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . PM-1

CA08102001E

Page 19: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

CA08102001E For more

19

48-Operator InterfacesAccessories PanelMate

January 2003Vol. 2, Ref. No. [1151]

48

Accessories

Table 48-49. For PanelMate 500 and PanelMate Power Series 1500

Table 48-50. For PanelMate 1000

Table 48-51. For PanelMate 1100, 1500, 1700, 2000, 3000, 4000, 5000

Table 48-52. For PanelMate 1100, 1700, 2000, 3000, 4000, 5000

Power Supplies

Table 48-53. Power Supplies for Micro PanelMate D830, D840, D850; PanelMate 500; PanelMate Power Series 1500; PanelMate 1000; PanelMate Power Pro 1100, 1700, 3000, 5000

1 Does not support PanelMate Power Pro 1100, 1700, 3000, 5000 or ePro.

Description CatalogNumber

PriceU.S. $

Multi-Drop AdapterExternal stand-alone device that can mount to a PanelMate 500/1500 which allows easy daisy-chaining and termination of the PanelMate on DH-485/RS-485/RS-422 networks. The device supports both RJ45 and Phoenix-type connectors. [Includes 9 inch (229 mm) connection cable to connect to the PanelMate 500/1500.]

1511 83.

Description CatalogNumber

PriceU.S. $

Support KitIncludes Transfer Utility Option #1221

1212 161.

Description CatalogNumber

PriceU.S. $

Configuration Storage ModuleMemory unit that allows transfer of one configu-ration to or from the target PanelMate unit.

0614 399.

Description CatalogNumber

PriceU.S. $

Audio Feedback Kit 0807 145.

Description CatalogNumber

PriceU.S. $

115V AC to 24V DC Power Conversion Module 1 1216 161.

115/230V AC to 24V DC Power Conversion Module (Replaces 1219A)

1219B 245.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . PM-1

information visit: www.cutler-hammer.eaton.com

Page 20: Contents Operator Interfaces - MAssetRecovery · 2018. 8. 11. · utilizing Boolean logic and math functions. ... Like the D830, the tactile membrane keypad, navigation, re-definable

48-20

48

Operator InterfacesAccessories

PanelMate

For more information visit: www.cutler-hammer.eaton.com

January 2003Vol. 2, Ref. No. [1152]

Mounting Adapter CollarsAllows the installation of PanelMates in shallower enclosures or in place of other models.

Table 48-54. PanelMate 1500, 1700, 2000, 4000 Mounting Adapter Collars/Plates

1 Require cutting and drilling.

PanelMate Power Pro Overlay KitsTable 48-55. PanelMate Power Pro Overlay Kits

PanelMate Pro LT 1100 TagsThe PanelMate Pro LT 1100 I/O Reference Point Expansion is an upgrade kit that includes a hardware key and download software. The upgrades are provided on the hardware key and are downloaded to a PanelMate Pro LT 1100 from a PC using the provided hardware key and software. The PanelMate Pro LT supports 64 I/O points as standard and can be upgraded to support a maximum of 512 I/O points (7 upgrades installed).

Table 48-56. PanelMate Pro LT Expansion

2 Discount Symbol PM-2.

Description CatalogNumber

PriceU.S. $

Plates24XX TouchPanel to 1500/1700 TouchPanel 126XX/27XX TouchPanel to 1500/1700 TouchPanel 126XX/27XX Touchscreen to 1500/1700 Touchscreen 1

24XX TouchPanel to 1500/1700 Touchscreen26XX/27XX TouchPanel to 1500/1700 Touchscreen Collars24XX TouchPanel to 1500/1700 TouchPanel Collar26XX/27XX TouchPanel to 1500/1700 TouchPanel Collar

1524TP1527TP1527TS1524TPTS1527TPTS

1524TPCOLLAR1527TPCOLLAR

202.202.202.202.202.

202.202.

Models #42XX Keyboard Shelf OnlyPainted SteelStainless Steel

28042805

440.665.

Description CatalogNumber

PriceU.S. $

PanelMate Power Pro 1700T Anti-glare Overlay Kit, 5/kitPanelMate Power Pro 1700T Clear Protective Overlay Kit, 5/kitPanelMate Power Pro 3000K/T Anti-glare Overlay Kit, 5/kitPanelMate Power Pro 3000K/T Clear Protective Overlay Kit, 5/kitPanelMate Power Pro 5000K/T Anti-glare Overlay Kit, 5/kitPanelMate Power Pro 5000K/T Clear Protective Overlay Kit, 5/kit

17AGT17CPT39AG39CP55AG55CP

104.104.104.104.104.104.

Description CatalogNumber

PriceU.S. $

I/O Reference Point Expansion (64 points per upgrade) 2

1 x 64 I/O point expansion5 x 64 I/O point expansion

10 x 64 I/O point expansion50 x 64 I/O point expansion

1100TAG11100TAG51100TAG101100TAG50

306.1,345.2,380.

10,350.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . PM-1

CA08102001E