From Our Reference Tel Fax
ST-ESS/PRM3 Martin Herold
Installation instruction
Security Systems
Grasbrunn
20 Feb 2013
Page 1 of 12
Issue Topic Upgrading BRS Appliance from BRS version 8.10 to version
8.11 Description
Content 1 Introduction ......................................................................................................................... 1 2 Upgrading BRS application from v8.10 to v8.11 .................................................................. 2
2.1 Saving configuration file ............................................................................................... 2 2.2 Uninstalling BRS v8.10 ................................................................................................ 3 2.3 Installing BRS v8.11 .................................................................................................... 4
3 Configuring BRS Web Server settings ................................................................................ 6 3.1 Configuring DCOM Permissions .................................................................................. 6
4 Upgrading BVIP ConfigManager from v4.33 to v4.41 ........................................................ 11 4.1 Uninstalling BVIP ConfigManager v4.33 .................................................................... 11 4.2 Installing BVIP ConfigManager v4.41 ........................................................................ 12
1 Introduction This document describes the software upgrade of BRS Appliance from v8.10 to v8.11. Note: The image on the SATA-DOM is not touched by this instruction. After resetting the BRS Appliance from the SATA-DOM, the earlier BRS version 8.10 is installed on the BRS Appliance again. To upgrade the unit to v8.11 this instruction has to be followed again then. To upgrade BRS Appliance from v8.10 to v8.11, perform the following steps:
• Upgrading BRS application from v8.10 to v8.11 (see chapter 2) • Configuring BRS Web Server settings (see chapter 3) • Upgrading BVIP ConfigManager from v4.33 to v4.41 (see chapter 4)
From Our Reference Tel Fax
ST-ESS/PRM3 Martin Herold
Installation instruction
Issue
Topic Upgrading BRS Appliance from BRS version 8.10 to version 8.11
Security Systems
Grasbrunn
20 Feb 2013
Page 2 of 12
2 Upgrading BRS application from v8.10 to v8.11 To upgrade BRS application from v8.10 to v8.11, perform the following steps:
1. Saving configuration file (see page 2) 2. Uninstalling BRS v8.10 (see page 3) 3. Installing BRS v8.11 (see page 4)
2.1 Saving configuration file To save the BRS configuration file
1. Logon Windows as administrator (during startup press Shift key to get the logon mask) 2. Right-click Bosch Recording Station, select Run as administrator.
3. Logon BRS as Administrator
4. System > Configuration
In Options > under Configuration data, click Save.
From Our Reference Tel Fax
ST-ESS/PRM3 Martin Herold
Installation instruction
Issue
Topic Upgrading BRS Appliance from BRS version 8.10 to version 8.11
Security Systems
Grasbrunn
20 Feb 2013
Page 3 of 12
5. Save vidsys.prm in e.g. D:\ and click Save.
6. Click OK. 7. Exit Configuration and exit BRS application.
2.2 Uninstalling BRS v8.10 To uninstall BRS v8.10
1. Start > Control Panel > Programs > Uninstall a program > select Bosch Recording Station and click Uninstall.
From Our Reference Tel Fax
ST-ESS/PRM3 Martin Herold
Installation instruction
Issue
Topic Upgrading BRS Appliance from BRS version 8.10 to version 8.11
Security Systems
Grasbrunn
20 Feb 2013
Page 4 of 12
2. Click Yes.
3. Click Finish to restart the system.
4. Logon Windows as administrator (during startup press Shift key to get the logon mask)
2.3 Installing BRS v8.11 To install BRS v8.11
1. Install BRS application version 8.11.0.116 (Setup.exe) from e.g. BRS 8.11 Setup DVD (BRS Tower) or USB memory stick (BRS rackmount). Follow the instructions on the screen.
2. Keep Setup Type Bosch Recording Station (recorder/receiver) selected > click Next.
From Our Reference Tel Fax
ST-ESS/PRM3 Martin Herold
Installation instruction
Issue
Topic Upgrading BRS Appliance from BRS version 8.10 to version 8.11
Security Systems
Grasbrunn
20 Feb 2013
Page 5 of 12
3. Keep default path > click Next.
4. Click Finish to restart the system.
5. Login Windows as administrator (during startup press Shift key to get the logon mask) 6. Right-click Bosch Recording Station, select Run as administrator. 7. Usually the configuration is kept, BRS is starting up.
If requested, load the BRS Configuration file, saved in chapter 2.1.
8. Restart the system, BRSuser logs on automatically.
From Our Reference Tel Fax
ST-ESS/PRM3 Martin Herold
Installation instruction
Issue
Topic Upgrading BRS Appliance from BRS version 8.10 to version 8.11
Security Systems
Grasbrunn
20 Feb 2013
Page 6 of 12
3 Configuring BRS Web Server settings To configure the Web Server logon Windows as administrator (during startup press Shift key to get the logon mask) Note: Do not start BRS application during configuring the Web Server. To configure BRS Web Server for BRS v8.11, perform the following steps:
1. Configuring DCOM Permissions (see page 6)
3.1 Configuring DCOM Permissions To configure DCOM permissions
1. Control Panel > System and Security > Administrative Tools > Component Services >
2. Component Services > Computers > My Computer > DCOM Config 3. Quit 2 warning windows with click on No. 4. Right-click VirtualInputs > Properties.
From Our Reference Tel Fax
ST-ESS/PRM3 Martin Herold
Installation instruction
Issue
Topic Upgrading BRS Appliance from BRS version 8.10 to version 8.11
Security Systems
Grasbrunn
20 Feb 2013
Page 7 of 12
5. Tab Security Under Launch and Activation Permissions, select Customize, click Edit.
6. In Launch and Activation Permissions, click Add…
7. In the Select Users or Groups dialog box, click Advanced…
From Our Reference Tel Fax
ST-ESS/PRM3 Martin Herold
Installation instruction
Issue
Topic Upgrading BRS Appliance from BRS version 8.10 to version 8.11
Security Systems
Grasbrunn
20 Feb 2013
Page 8 of 12
8. Click Find Now. Then select IUSR, and then click OK.
9. The name is displayed in Select Users or Groups dialog box.
Click OK.
10. Select IUSR, > in the Allow column, select Local Activation.
11. Click OK.
From Our Reference Tel Fax
ST-ESS/PRM3 Martin Herold
Installation instruction
Issue
Topic Upgrading BRS Appliance from BRS version 8.10 to version 8.11
Security Systems
Grasbrunn
20 Feb 2013
Page 9 of 12
12. Under Access Permissions select Customize, click Edit.
13. In Access Permissions, click Add…
14. In the Select Users or Groups dialog box, click Advanced…
From Our Reference Tel Fax
ST-ESS/PRM3 Martin Herold
Installation instruction
Issue
Topic Upgrading BRS Appliance from BRS version 8.10 to version 8.11
Security Systems
Grasbrunn
20 Feb 2013
Page 10 of 12
15. Click Find Now. Then select IUSR, and then click OK.
16. The name is displayed in Select Users or Groups dialog box.
Click OK.
17. Select IUSR, > in the Allow column, select Local Access.
18. Click OK, and then click OK again. 19. Close Component Services, and then close Control Panel. 20. Reboot the computer.
From Our Reference Tel Fax
ST-ESS/PRM3 Martin Herold
Installation instruction
Issue
Topic Upgrading BRS Appliance from BRS version 8.10 to version 8.11
Security Systems
Grasbrunn
20 Feb 2013
Page 11 of 12
4 Upgrading BVIP ConfigManager from v4.33 to v4.41 To upgrade BVIP ConfigManager from v4.33 to v4.41, perform the following steps:
1. Uninstalling BVIP ConfigManager v4.33 (see page 11) 2. Installing BVIP ConfigManager v4.41 (see page 12)
4.1 Uninstalling BVIP ConfigManager v4.33 To uninstall BVIP ConfigManager v4.33
1. Logon Windows as administrator (during startup press Shift key to get the logon mask) 2. Start > Control Panel > Programs > Uninstall a program
> select Bosch Configuration Manager 04.33.0023.0 and click Uninstall/Change.
3. Click Yes.
4. Click OK.
5. Close Control Panel.
From Our Reference Tel Fax
ST-ESS/PRM3 Martin Herold
Installation instruction
Issue
Topic Upgrading BRS Appliance from BRS version 8.10 to version 8.11
Security Systems
Grasbrunn
20 Feb 2013
Page 12 of 12
4.2 Installing BVIP ConfigManager v4.41 To install BVIP ConfigManager v4.41
1. Install ConfigManager version 4.41.0037 from e.g. BRS 8.11 Setup DVD \Tools\BVIP Configuration Manager\ Setup_ConfigManager_04.41.0037.0.exe (BRS Tower) or USB memory stick (BRS rackmount). Follow the instructions on the screen.
2. De-select iqn-Mapper, de-select DSA E-Series Discovery and click Next.
3. Keep default path > click Install.
4. Click Finish.
5. Reboot the computer.