Construction with purlins
Unipur insulated roofpanelsTechnical details
UNILIN Systems
Ridge beam
UNILINroof panel
Wall plate
Intermediate
Tiling battens
beam
2
UNILIN Systems
UNILINroof panel
Tiles
Overhanging eaves
Unipur insulated roof panelsTechnical details
Breathable underlay
Sarking felt dressedinto gutter
Note: bolts and holdingdown straps not shown for convenience
3
overlapmin. 150mm
Wall plate
Concrete block
SpacerFascia
Soffit
Ridge
Unipur insulated roof panelsTechnical details
Ridge beam
UNILINroof panel
Breathable
Optional spacer
Unilin Systems
underlay
4
Hip
Unipur insulated roof panelsTechnical details
Optional spacer on hip rafter
Note: Check the angle degree before cutting diagonally
Unilin Systems5
UNILINroof panel
Lead lining
Valley rafter
Breathable underlay
Plywood
Tile
Valley
Unipur insulated roof panelsTechnical details
Note: Check the angle degree before cutting diagonally
Unilin Systems
6
Verge
Unipur insulated roof panelsTechnical details
Timber Tiling batten roof panelUNILIN
Purlin (fixed into the internal wall)
Strap
Chamferd edge
FasciaSoffit
Airspace
Unilin Systems7
Dormer window
Unipur insulated roof panels
Trimmer
PUR-foam
Trimmer
Trimmer
Technical details
underlay
A-A
B-B
Trimmer
Unilin Systems
Breathable
8
UNILIN Systems
Rooflights
Unipur insulated roofpanelsTechnical details
Trimmer for rooflights
Rooflights larger then 2 sqm must be supported on beams
9
Chimney
Unipur insulated roof panelsTechnical details
UNILINroof panel
Lead gutter
(f.i. mineral wool)Incombustible material
Flue liner
Flue
Lead
Chimney
Breathable
Underlay
Unilin Systems
underlay
10
Partywall
Unipur insulated roof panelsTechnical details
Purlin Purlin
Partywall
Gypsumboard
Fire resistant PU-foam
PurlinPartywall
Non- combustiblefire stopping material
Option 1:
Option 2:
Non-combustible fire stoppingmaterial (f.i. fire resistant PU-foam)
Purlin
Gypsumboard (min 9mm)
Gypsumboard (min 9mm)
Unilin Systems
11
Type 1 Type 2 Type 3
0 to 60° 0 to 60° 0 to 60°
Type 4 Type 5 Type 6
30 to 90° 30 to 60° 30 to 90°
Type7 Type 8
30 to 90° 30 to 60°
L. : total lengthl : internal lengthα : angle°
α
L.
lα
L.
α
L.
l
α
L.
lα
L.
lα
L.
α
L.
lα
L.
Angle cut types
Unipur insulated roof panelsTechnical details
specify :
UNILIN Systems12
α
L.
Type 0
Angle dimensions, degrees °°
Unipur insulated roof panelsTechnical details
mm (α)
2000 63°30 200 %2230
1950 63°00 195 %2190
1900 62°15 190 %2140
1850 61°30 185 %2120
1800 61°00 180 %2050
1750 60°15 175 %2010
1700 59°30 170 %1970
1650 58°45 165 %1930
1600 58°00 160 %1880
1550 57°00 155 %1840
1500 56°15 150 %1800
1450 55°30 145 %1760
1400 54°30 140 %1720
1350 53°30 135 %1680
1300 52°30 130 %1640
1250 51°15 125 %1600
1200 50°15 120 %1560
1150 49°00 115 %1520
1100 47°45 110 %1480
1050 43°30 105 %1450
1000 45°00 100 %1410
950 43°30 095 %1380
900 42°00 090 %1340
850 40°15 085 %1310
800 38°30 080 %1280
750 37°00 075 %1250
700 35°00 070 %1220
650 33°00 065 %1190
600 31°00 060 %1160
550 28°45 055 %1140
500 26°30 050 %1110
450 24°15 045 %1090
400 21°45 040 %1070
350 19°15 035 %1060
300 16°45 030 %1040
250 14°00 025 %1030
200 11°15 020 %1020
150 08°30 015 %1010
ba
1000 mm
α
b angle in
a degrees
mm
13
UNILIN Systems