NX-Series PROFINETTM Coupler Unit Connection Guide SIEMENS Corporation PLC (P-210287)

1

NX-series PROFINETTMCoupler Unit

Connection Guide

SIEMENS Corporation PLC SBCA-xxxx

Page 2: [Connection Guide] NX-PNC SIEMENS RevA01

NX-Series PROFINETTM Coupler Unit Connection Guide SIEMENS Corporation PLC (P-210287)

2

目 次

1. Related Manuals .......................................................................................... 3

2. Precautions .................................................................................................. 4

3. Overview ...................................................................................................... 5

4. Applicable Devices and Device Configuration ........................................ 6

4.1. Applicable Devices ................................................................................ 6

4.2. Device Configuration ............................................................................. 7

4.3. Network Information .............................................................................. 9

5. Communication Procedure ...................................................................... 10

5.1. Work Flow ............................................................................................ 10

5.2. Slave Terminal Setup ........................................................................... 12

5.3. Offline Configuration of SIEMENS TIA Portal...................................... 20

5.4. Download to SIEMENS PLC ............................................................... 35

5.5. Configuring a PROFINET Device ........................................................ 39

6. Revision History ........................................................................................ 47

Page 3: [Connection Guide] NX-PNC SIEMENS RevA01

3

1. Related Manuals To ensure system safety, always read and follow the information provided in all Safety

Precautions and Precautions for Safe Use in the manuals for the devices that are used in the

system.

Manufacture Cat. No. Model Manual name

OMRON W536 NX-EIC202 Machine Automation Controller

NX-series EtherNet/IP™ Coupler Unit

User’s Manual

OMRON W504 - Sysmac Studio Version 1 Operation Manual

SIEMENS - MELSEC-S7-1200 S7-1200 Programmable Controller

System Manual

Page 4: [Connection Guide] NX-PNC SIEMENS RevA01

4

2. Precautions

(1) Understand the specifications of devices which are used in the system. Allow some margin

for ratings and performance. Provide safety measures, such as installing a safety circuit, in

order to ensure safety and minimize the risk of error occurrence.

(2) To ensure system safety, make sure to always read and follow the information provided in

all Safety Precautions and Precautions for Safe Use in the manuals for each device which is

used in the system.

(3) The user is encouraged to confirm the standards and regulations that the system must

conform to.

(4) It is prohibited to copy, to reproduce, and to distribute a part or the whole of this document

without the permission of OMRON Corporation.

(5) The information contained in this document is current as of March 2021. It is subject to

change for improvement without notice.

The following notations are used in this document.

Indicates a potentially hazardous situation which, if not avoided,

may result in minor or moderate injury, or may result in serious

injury or death. Additionally there may be significant property

damage.

Indicates a potentially hazardous situation which, if not avoided,

may result in minor or moderate injury or property damage.

Precautions for Correct Use

Precautions on what to do and what not to do to ensure proper operation and performance.

Additional Information

Additional information to read as required.

This information is provided to increase understanding or make operation easier.

Symbol

The filled circle symbol indicates operations that you

must do.

The specific operation is shown in the circle and

explained in the text. This example shows a general

precaution for something that you must do.

Page 5: [Connection Guide] NX-PNC SIEMENS RevA01

5

3. Overview This document summarizes the procedures and programs required to connect an OMRON

Corporation NX-series PROFINET Communication Coupler Unit (hereinafter referred to as

"NX-PNC") + various NX-series Units to a Siemens PLC for PROFINET communication.

This document describes the procedures for connecting MITSUBISHI PLC to

EtherNet/IP Coupler Unit via socket communications.

For operations and system configurations that are not specified in this

document, obtain the manuals of the component devices of the system and

check the information in each manual, including safety precautions, precautions

for safe use.

Page 6: [Connection Guide] NX-PNC SIEMENS RevA01

6

4. Applicable Devices and Device Configuration

4.1. Applicable Devices

The applicable devices are as follows.

Manufacture Name Model

OMRON PROFINET Coupler Unit NX-PNC202

SIEMENS CPU Unit S7-1200

Precautions for Correct Use

In this document, the devices with models and versions listed in 4.2. Device Configuration are

used as examples of applicable devices to describe the procedures for connecting the

devices and checking their connections.

You cannot use devices with versions lower than the versions listed in 4.2.

To use the above devices with models not listed in 4.2. or versions higher than those listed in

4.2., check the differences in the specifications by referring to the manuals before operating

the devices.

Additional Information

This document describes the procedures for establishing the network connections and

performing PRFINET communications. It does not provide information on operation,

installation, wiring method, device functionality, or device operation, which is not related to

the connection procedures. Refer to the manuals or contact the manufacture of the product.

Page 7: [Connection Guide] NX-PNC SIEMENS RevA01

7

4.2. Device Configuration

The hardware components to reproduce the connection procedures in this document are as

follows.

Manufacture Name Model Version

OMRON NX-series PROFINETTM Coupler Unit

NX-PNC202 Ver.1.0

OMRON NX-series Unit NX-[][][][] -

OMRON Sysmac Studio SYSMCAC-SE2[][][] Ver1.19 SIEMENS CPU Unit S7-1200 - SIEMENS Ethernet Switch SCALANCE XB208 - SIEMENS TIA Portal -

- Personal computer (OS: Windows10)

LAN cable (STP (shielded, twisted-pair) cable

of Ethernet category 5 or higher) -

- USB cable (For connecting NX-PNC202) (USB 2.0 type B connector)

- 24 VDC power supply (Unit power supply)

- 24 VDC power supply (I/O power supply)

Precautions for Correct Use

The connection has been checked with the models and versions listed in this document. If

you use a model or version that is not listed here, please check the differences in

specifications in the instruction manual before starting work.

PC Tool: TIA Portal

PROFINET Coupler Unit NX-PNC202

PC Tool: Sysmac Studio

PLC: S7-1200

NX-Units NX-ID3343 NX-OD3153

USB Cable

LAN Cable

USB

Communic

ation Ethernet Switch:

XB208

Signal Cable

Page 8: [Connection Guide] NX-PNC SIEMENS RevA01

8

Additional Information

For the IO loopback signal line, connect Port 1 of NX-ID3343 and NX-OD3253.

Page 9: [Connection Guide] NX-PNC SIEMENS RevA01

9

4.3. Network Information

The network information (IP address/Subnet mask) for this configuration is as follows.

192.168.0.100 / 24

PC

PNC Coupler Unit NX-PNC202

PLC: S7-1200

Ethernet Switch XB208

192.168.0.2 / 24

192.168.0.1 / 24

192.168.0.3 / 24

Page 10: [Connection Guide] NX-PNC SIEMENS RevA01

10

5. Communication Procedure This chapter describes the procedures to communicate between SIEMENS PLC and

NX-PNC.

It is assumed that the NX-PNC is in the factory default settings.

5.1. Work Flow

The procedure to connect SIEMENS PLC and NX-PNC by Ethernet and to communicate is as

follows.

5.2. Slave Terminal Setup Configure the slave terminal settings.

5.2.1. Hardware Settings

Attach the NX Unit to the NX-PNC, set

the hardware switches and connect the

cables.

5.2.2. Parameter Settings

Sets the parameters of the slave

terminal.

5.3. Offline Configuration of SIEMENS TIA Portal Configure offline settings for SIEMENS

TIA Portal.

5.3.1. Create a Project

Create a project in TIA Portal and add a

CPU unit.

5.3.2. Ethernet Switch Configuration Settings

Add a switching hub to the

configuration.

5.3.3. Installing the GSD file

Install the GSD file of NX-PNC into TIA

Portal.

5.3.4. Adding and Setting Remote IO Stations

Add a remote IO station.

5.3.5. Assigning a PROFINET Network Station

Assign a PROFINET network IO

station.

5.3.6. IP Address Setting (PLC) Set the IP address of the PLC.

5.3.7. Set the IP address ( Switch , NX-PNC)

Set the IP address of the switching

HUB and NX-PNC.

Page 11: [Connection Guide] NX-PNC SIEMENS RevA01

11

5.4. Download to SIEMENS PLC Download the configuration to the

SIMENS PLC.

5.4.1. Compiling the Configuration Compile the project.

5.4.2. Download the configuration to the PLC Download the project to the PLC.

5.5. Configuring a PROFINET Device Set the IP address and device name of

the PROFINET device.

5.5.1. Updating the Device List on PROFINET

Update the devices on the network,

including the PLC.

5.5.2. Change the PROFINET settings of the

PLC

Set the IP address and device name of

the PLC.

5.5.3. Change PROFINET setting of remote IO

station

Set the IP address and device name of

the switching HUB and NX-PNC.

5.5.4. Checking the PROFINET network

connection

Check the PROFINET network

connection.

Page 12: [Connection Guide] NX-PNC SIEMENS RevA01

12

5.2. Slave Terminal Setup

Set up slave terminal.

Install Sysmac Studio on Personal computer in advance.

Hardware Settings

1 Make sure that NX-PNC is

powered OFF.

2 Connect each NX Unit to EIP

Coupler.

3 Check the location of the NX-PNC's hard switches and connectors based on the figure on the right.

4 Make sure that all DIP switches

are OFF.

SW1-SW4 is All Off

Page 13: [Connection Guide] NX-PNC SIEMENS RevA01

13

5 Make sure that all rotary switches

are zero.

ADR No.x161: 0

ADR No.x160: 0

Page 14: [Connection Guide] NX-PNC SIEMENS RevA01

14

Parameter Settings Set the parameters for Slave Terminal.

Parameters are set from Sysmac Studio.

Install Sysmac Studio and the USB driver on Personal computer in advance.

Additional Information

For information on how to install SysmacStudio and USB driver, refer to A-1

Driver Installation for Direct USB Cable Connection in Appendices of the Sysmac Studio

Version 1 Operation Manual (Cat. No. W504).

Additional Information

An NX-PNC and NX Unit on the Slave Terminal can be used without settings of unit operation

and configuration information of the NX Unit by support software. In this case, the default

setting of the NX Unit is used for operation.

1 Connect NX-PNC and

Personal computer via a USB,

and then turn ON the power

supply to Slave Terminal.

2 Start Sysmac Studio.

3 Sysmac Studio starts.

Click New Project.

NX-PNC

PC Sysmac Studio

USB

Communication

Page 15: [Connection Guide] NX-PNC SIEMENS RevA01

15

4 The Project Properties dialog

box is displayed.

*In this document, New Project

is used as the project name.

Select Slave Terminal from

the pull-down list of Category.

5 Make sure that PROFINET

Coupler is selected in the

Device field.

Click Create.

6 The New Project dialog box is displayed. The following panes are

displayed in this window. Left: Multiview Explorer Middle top: EIP Tab Page Top right: Toolbox

The following tabs are

displayed in the bottom middle

of this window.

Output Tab Page Build Tab Page

Multiview Explorer

Output Tab Page Build Tab Page

Toolbox

EIP Tab Page

Page 16: [Connection Guide] NX-PNC SIEMENS RevA01

16

7 From Multiview Explorer,

double-click Configuration >

PROFINET > NX-PNC202.

8 Double-click NX-PNC202

under Configurations and

Setup -

PROFINET in the Multiview

Explorer.

9 A confirmation dialog box is

displayed. Check the contents

and click OK.

10 When an online connection is

established, a yellow bar is

displayed under the toolbar.

Page 17: [Connection Guide] NX-PNC SIEMENS RevA01

17

11 Right-click the device icon of

Coupler Unit and select

Compare and Merge with

Actual Network

Configuration.

12 The Compare and Merge with

Actual Unit Configuration

dialog box is displayed.

Page 18: [Connection Guide] NX-PNC SIEMENS RevA01

18

13 Click Apply Actual Unit

Configuration.

14 Click OK.

15 Right-click the device icon of

Coupler Unit and select

Coupler Connection (USB) -

Transfer to Coupler from the

Menu.

16 The Transfer to Coupler dialog

box is displayed.

Click Configuration

information + Unit operation

settings + Unit application

Data.

Page 19: [Connection Guide] NX-PNC SIEMENS RevA01

19

17 A confirmation dialog box is

displayed. Check the contents

and click Yes.

A screen is displayed stating

"Transfer to Coupler".

18 Right-click NX-ENC202 and

select Coupler Connection

(USB) - Offline

Page 20: [Connection Guide] NX-PNC SIEMENS RevA01

20

5.3. Offline Configuration of SIEMENS TIA Portal

SIEMENS TIA Portal V16 (hereinafter referred to as TIA Portal) is used for offline

configuration.

Please install TIA Portal on your PC in advance.

Create a Project

1 Launch the TIA Portal. Double-click on the icon on your desktop.

2 Select "Create new project”.

3 Specify the Project name and the Path where you want to create the project, and select Create.

Select "Create".

Page 21: [Connection Guide] NX-PNC SIEMENS RevA01

21

4 Select "Device & network".

5 Select "Add new device" and

then "Controllers".

6 Select

[Contorollers]

-[SIMATIC S7-1200]

-[CPU 1212C DC/DC/DC]

-[6ES6 212-1AE-40-0XB0]

Page 22: [Connection Guide] NX-PNC SIEMENS RevA01

22

7 Select "Add".

8 The CPU will be added to the

project and the Device View will

be displayed.

Page 23: [Connection Guide] NX-PNC SIEMENS RevA01

23

Ethernet Switch Configuration Settings In this section, you will configure the settings to add the Ethernet switch configuration to the

project using the TIA Portal.

1 Double-click [Devices &

networks] from the list in the

[Devices] tab of the [Project

tree].

2 Click on the "Topology view" tab.

Page 24: [Connection Guide] NX-PNC SIEMENS RevA01

24

3 Select the Hardware catalog

tab, select [6GK5

208-0BA00-2AB2], drag it, and

drop it on the Topology View

screen to place it.

The [6GK5 208-0BA00-2AB2]

will be displayed in the [Network

Components]

-[IE switches]

-[SCALANCE X-200

managed]-[SCALANCE

XB-200].

-[SCALANCE XB208].

[Network Components] -[IE

switches] -[SCALANCE X-200

managed]-[SCALANCE

XB-200]-[SCALANCE XB208].

4 Verify that Switch_1

(SCALANCE XB208) has been

added as shown in the figure on

the right.

Page 25: [Connection Guide] NX-PNC SIEMENS RevA01

25

Installing the GSD file In this section, we will install the GSD file for NX-PNC.

1 Select "Manage general station

description files (GSD)" from the

list in the "Option" tab of the TIA

Portal.

2 In the Installed GSDs tab, click

the Select Source path button to

add the GSD file.

3 When the GSD file you added is

displayed, check the box and

press [Install].

Page 26: [Connection Guide] NX-PNC SIEMENS RevA01

26

Adding and Setting Remote IO Stations In this section, we will use TIA Portal to add and configure a remote IO station networked to a

Siemens PLC.

1 Double-click on "Devices & networks".

2 Select the Topology view tab.

3 Select the Hardware catalog tab,

select NX-PNC, drag it, and drop

it on the Topology View screen to

place it.

NX-PNC is located under

Other field devices

-[PROFINET IO] -[I/O

-[I/O] -[OMRON Corporation].

-[OMRON Corporation] -[NX

Remote I/O

-[NX Remote I/O Bus Coupler].

Select [Other field devices]

-[PROFINET IO] -[I/O] -[OMRON

Corporation] -[NX Remote I/O

Bus Coupler] to display.

Page 27: [Connection Guide] NX-PNC SIEMENS RevA01

27

Assigning a PROFINET Network Station In this section, we will use TIA Portal to configure the network connection of the remote IO

child station networked to the Siemens PLC.

1 Double-click on [Devices & networks] in the [Project tree].

2 Select the Network view tab.

Page 28: [Connection Guide] NX-PNC SIEMENS RevA01

28

3 Drag from the Ethernet port (green frame) of PLC_1, release the dragging when the black connection line appears, and click on the Ethernet port (green frame) of Switchch_1 to draw the connection line.

4 Follow the same procedure as step 3 to connect between PLC_1 and NX-PNC.

As shown in the figure on the right, all network lines will be connected.

5 Switch to [Topology view],

double-click the name of

NX-PNC202, and change the

name of "NX-PNC202" to "io_1".

Page 29: [Connection Guide] NX-PNC SIEMENS RevA01

29

6 Drag from the Ethernet port of PLC_1 (green frame), stop dragging when the black line extends, and click again on the P1 port of Switch_1 (upper left corner) to connect.

As shown in the figure on the right, you can set up the wiring from the X1 port of PLC_1 to the P1 port of Switch_1.

7 Similarly, set up the wiring

between the P2 port of Switch_1

and the X1 port of io_1 and

connect them.

Page 30: [Connection Guide] NX-PNC SIEMENS RevA01

30

IP Address Setting (PLC) In this section, we will use the TIA Portal to set the IP address of the Siemens PLC.

1 Double-click PLC_1 in the [Topology view] to display the [Device view].

When the cursor is placed on the CPU displayed in the [Device view] and it is focused with a blue frame, double-click it to display the Properties.

2 Properties tab General] tab From the list of PROFINET interface[X1]] -[Ethernet address] and set the IP address and

subnet mask to the following values.

IP address: 192.168.0.1 Subnet mask: 255.255.255.0

3 Properties tab General] tab From the list of PROFINET interface[X1]] -[Operating mode] and make sure that IO device is

unchecked. This indicates that PLC_1 is the

master station.

Page 31: [Connection Guide] NX-PNC SIEMENS RevA01

31

4 Properties tab General] tab From the list of PROFINET interface[X1]] -[Advanced options] -[Port[X1

P1]] -[Port[X1 P1]] -[Port[X1 P1]] -[Port

interconnection from the list of PROFINET

interface[X1] -[Advanced options] -[Port[X1 P1]] -[Port interconnection], and confirm that the connection destination of PLC_1 is port 1 of Switch_1.

Local port: Indicates the own

station. Partner port: Indicates the partner station.

Page 32: [Connection Guide] NX-PNC SIEMENS RevA01

32

Set the IP address ( Switch , NX-PNC) In this section, you will set the IP address of the remote IO child station side using TIA Portal.

Set the IP address of the Ethernet switch and NX-PNC.

1 Select Switch_1 from the Device view screen to display Switch_1, then double-click the device to display its Properties.

2 Properties tab General] tab From the list of PROFINET interface[X]] -[Ethernet addresses] from the list of [PROFINET

interface[X]]-[Ethernet addresses], and set the IP address and subnet mask as follows.

IP address: 192.168.0.2 Subnet mask: 255.255.255.0

3 Properties tab General] tab From the list of PROFINET interface[X]] -[Advanced options] -[Port [X1 P1]] -[Port [X1 P1]] -[Port

interconnection and make sure that port 1 of Switch_1 is connected to port X1 of PLC_1.

Page 33: [Connection Guide] NX-PNC SIEMENS RevA01

33

4 Properties tab General] tab From the list of PROFINET interface[X]] -[Advanced options] -[Port [X1 P2]] -[Port [X1 P2]] -[Port

interconnection and make sure that port 2 of Switch_1 is connected to port 1 (X1 P1) of io_1 (NX-PNC).

5 Select io_1 from the Device view screen to display io_1, then double-click the device to display its Properties.

6 Properties tab General] tab From the list of PROFINET interface[X]] -[Ethernet addresses] from the list of [PROFINET

interface[X]]-[Ethernet addresses], and set the IP address and subnet mask as follows.

IP address: 192.168.0.3 Subnet mask: 255.255.255.0

Page 34: [Connection Guide] NX-PNC SIEMENS RevA01

34

7 Properties tab General] tab From the list of PROFINET interface[X]] -[Advanced options] -[Port [X1 P1 R]] -[Port [X1 P1 R]] -[Port

interconnection and confirm that the connection destination for io_1 (NX-PNC) is port 2 (X1 P2) of Switch_1.

8 Properties tab General] tab From the list of PROFINET interface[X]] -[Advanced options] -[Port [X1 P2 R]] -[Port interconnection]]. and confirm that the connection

destination for port 2 of io_1 (NX-PNC) is set to "Any partner".

Page 35: [Connection Guide] NX-PNC SIEMENS RevA01

35

5.4. Download to SIEMENS PLC

Download the settings to the SIEMENS PLC.

Download the settings to the SIEMENS PLC via TIA Portal.

Compiling the Configuration To download the file, run the compilation and make sure it is error-free.

1 Right-click [PLC_1[CPU 1212C DC/DC/DC]] in the list of [Device] tab of [Project tree], and select [Compile] - [Hardware and software(only changes)] in the context menu list.

-[Hardware and software(only changes)

Select [Hardware and software(only changes)] from the context menu list.

2 Make sure that there are zero errors displayed in the compilation results shown in the window at the bottom of the tool.

Page 36: [Connection Guide] NX-PNC SIEMENS RevA01

36

Download the configuration to the PLC Download the configuration to the Siemens PLC.

参考

Make sure that the IP address of the source PC of the download to be configured is in the

same network segment as the Siemens PLC.

In this manual, the IP address of the source PC is set to "192.168.0.100".

1 Right-click on [PLC_1[CPU 1212C DC/DC/DC]] in the [Devices] tab list of the [Project tree].

in the [Devices] tab list of the [Project tree] and click [Download to device] from the context menu.

Download to device -[Hardware and software(only

changes) Select [Download to device] - [Hardware and software(only changes)] from the context menu.

2 Select the network interface of the source PC and press "Start search" to search for the PLC on the network.

Page 37: [Connection Guide] NX-PNC SIEMENS RevA01

37

3 When a PLC is found, the result of the finding will be displayed.

With the destination device (PLC_1) selected, press the "Load" button.

You can check if the destination device is correct by turning on the "Flash LED" check box. When the check is ON, the front LED of the target device will blink.

4 Press the "Load" button. (The transfer will start.)

5 Select "Start module" and click the "Finish" button.

Page 38: [Connection Guide] NX-PNC SIEMENS RevA01

38

参考

When "Load" is executed, if the screen looks like the following, you will be asked if you want

to STOP the RUN of the PLC. Change the "Stop modules" setting from "No action" to "Stop

all" to stop the ladder program, and then click the "Load" button.

Page 39: [Connection Guide] NX-PNC SIEMENS RevA01

39

5.5. Configuring a PROFINET Device

Set the IP address and device name of the PROFINET device.

Updating the Device List on PROFINET

1 From the list of [Devices] in the [Project tree], browse to [Online access] and select [Update accessible devices] for the NIC of the PC that is using TIA Portal.

2 The device list will be updated.

Page 40: [Connection Guide] NX-PNC SIEMENS RevA01

40

Change the PROFINET settings of the PLC

1 Expand the tree of a[192.168.0.100].

, and double-click "Online & diagnostics

The figure on the right shows

the device with the following settings in the PLC.

Device name: a IP: 192.168.0.100

The following settings are used for the PLC.

Device name: a

IP address: 192.168.0.100

2 Open [Functions]-[Assign IP address].

Set IP address to "192.168.0.1". Set Subnet mask to

"255.255.255.0 Click the "Assign IP address"

button.

Page 41: [Connection Guide] NX-PNC SIEMENS RevA01

41

3 [Functions] -[Assign PROFINET device name

-[Assign PROFINET device name].

and select Configured PROFINET device. Set the PROFINET device name

to Set the PROFINET device name

in the Configured PROFINET device to "plc_1" and click the "Assign name" button.

Page 42: [Connection Guide] NX-PNC SIEMENS RevA01

42

Change PROFINET setting of remote IO station

1 b Expand the [192.168.0.99] tree, and double-click "Online & diagnostics".

Double-click "Online & diagnostics".

The following settings are used for the Switch.

Device name: b

IP address: 192.168.0.99

2 Open [Functions]-[Assign IP address]

Set the IP address to Set IP address to "192.168.0.2"

and Subnet mask to "255.255.255.0

Click the "Assign IP address" button.

3 [Functions] -[Assign PROFINET device name

and select Configured PROFINET device. Set the PROFINET device name to "switch_1".

Page 43: [Connection Guide] NX-PNC SIEMENS RevA01

43

4 Click on the "Assign name" button.

5 nx-pnc202[00-00....] Expand the tree of "Online & diagnostics

Double-click "Online & diagnostics".

6 Open [Functions]-[Assign IP address].

Set IP address to "192.168.0.3" and Subnet mask to "255.255.255.0

Click the "Assign IP address" button.

Page 44: [Connection Guide] NX-PNC SIEMENS RevA01

44

7 [Functions] -[Assign PROFINET device name

-[Assign PROFINET device name].

and select Configured PROFINET device. Set the PROFINET device name

to Set the PROFINET device name in Configured PROFINET device to "io_1".

8 Click on the "Assign name" button.

Page 45: [Connection Guide] NX-PNC SIEMENS RevA01

45

Checking the PROFINET network connection Verify that the PROFINET network is configured correctly.

1 Select "PLC_1" in the [Project tree] and click the [Go online] button.

2 Select (check) the device (PLC_1) that you want to connect.

3 Press the "Go Online" button to go online.

Page 46: [Connection Guide] NX-PNC SIEMENS RevA01

46

4 If they are connected correctly, they will all be checked green.

Page 47: [Connection Guide] NX-PNC SIEMENS RevA01

47

6. Revision History

Revision

code

Revised date Revised content

A01 March 9, 2021 Draft

About Intellectual Property Rights and Trademarks

Microsoft product screen shots reprinted with permission from Microsoft Corporation.

Windows is a registered trademark of Microsoft Corporation in the USA and other countries.

Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other

countries for OMRON factory automation products.

Company names and product names in this document are the trademarks or registered

trademarks of their respective companies.