© 2010 IBM Corporation
Configurar Equipos Storage en el TPC
© 2010 IBM Corporation
2
4 FC
16 FC
Brocade B64 Fabric
TPC 4.2.1 ServerW2008
4 FC
2 FC
X FC
TPC 4.2.1 demo platform
SVC 6.1 ClusterCF8 nodes
CIMOMs serverIP : 10.3.41.21
DS5000A DS8800XIV Site2
Brocade M48 Fabric
Storwize V7000
x FC
© 2010 IBM Corporation
3
Tipos de conexion al TPC
Dependiendo del tipo de Storage, el TPC se comunica a esos equipos a través de dos formas:
-Interfase nativa-Agente CIMOM
Los equipos que se comunican por interfase nativa son:•DS8000•SAN Volume Controller•XIV•Storwize V7000
Los equipos que deben utilizar un agente CIMOM instalado en un servidor son:•DS3K, DS4K, DS5K•Switches y Directores Brocade•Librerias de backup•Equipos antiguos como Shark
Los equipos que tienen un agente CIMOM embebido en el mismo equipo:•DS8000 con firmware antiguo •Switches Cisco
© 2010 IBM Corporation
4
Native CLI
SMIS protocol
© 2010 IBM Corporation
5
4 FC
16 FC
Brocade B64 Fabric
TPC 4.2.1 ServerW2008
4 FC
2 FC
X FC
TPC Management / CIMOM Agents (SMIS Protocol)
SVC 6.1 ClusterCF8 nodes
DS5000A DS8800XIV Site2
Brocade M48 Fabric
Storwize V7000
x FC
Brocade CIMOMDev : B64 & M48
SMIS
SMISDS5000 CIMOMDev : DS5000A & B
CIMOMs serverIP : 10.3.41.21
© 2010 IBM Corporation
6
4 FC
16 FC
Brocade B64 Fabric
TPC 4.2.1 ServerW2008
4 FC
2 FC
X FC
TPC Management / Native Interfaces
SVC 6.1 ClusterCF8 nodes
DS5000A DS8800XIV Site2
Brocade M48 Fabric
Storwize V7000
x FC
Brocade CIMOMDev : B64 & M48
SMIS
SMISDS5000 CIMOMDev : DS5000A & B
CIMOMs serverIP : 10.3.41.21
Native Interface
Native Interface
Native Interface
Native Interface
© 2010 IBM Corporation
7
4 FC
16 FC
TPC 4.2.1 ServerW2008
4 FC
2 FC
X FC
TPC Management / Out of Band- Fabric Agents (snmp Protocol)
SVC 6.1 ClusterCF8 nodes
DS5000A DS8800XIV Site2
Brocade M48 Fabric
Storwize V7000
x FC
Brocade CIMOMDev : B64 & M48
DS5000 CIMOMDev : DS5000A & B
CIMOMs serverIP : 10.3.41.21
M48 snmp agentB64 snmp agent
snmp
snmp
© 2010 IBM Corporation
8
Como configurar un nuevo Storage en TPC
Configurar el nuevo Storage utilizando el “Configure Devices” wizard
© 2010 IBM Corporation
9
“Configure Devices” wizard
© 2010 IBM Corporation
10
“Configure Devices” wizard
© 2010 IBM Corporation
11
“Configure Devices” wizard : DS8000
© 2010 IBM Corporation
12
“Configure Devices” wizard : XIV
© 2010 IBM Corporation
13
“Configure Devices” wizard : SVC or Storwize V7000
© 2010 IBM Corporation
14
“Configure Devices” wizard : Other / CIMOM agent
© 2010 IBM Corporation
15
CIMOM Agents configuration détail CIMOM Brocade :
– Location & IP: IP del servidor en donde está instalado el agente– Protocol & port : http / 5990– Interrop name space : /interop– Devices managed : Según sea el caso
CIMOM DS5000 :– Location & IP: IP del servidor en donde está instalado el agente– Protocol & port : http / 5988– Interrop name space : /interop– Devices managed : Según sea el caso
© 2010 IBM Corporation
16
CIMOM Agents configuration : Brocade1) CIMOM Agent definition in TPC :
2) CIMOM Agent configuration (devices managed ) on windows server :File C:\SMIAgent\agent\server\jserver\bin\provider.xml (modificar las Ips segun el caso)
© 2010 IBM Corporation
17
CIMOM Agents configuration : LSI
2) Agregar la definición del CIMOM Agent en el TPC en caso no exista
1) En el servidor en donde está instalado el CIMOM:a)Ingresar a la ruta de configuración del agente CIMOM (ver nota)b)En esa ruta abrir el archivo firmware_soportado.txt y validar si el firmware del equipo DS se encuentra dentro de los firmware indicados en el archivo, caso contrario buscar otro CIMOM. SI SE AGREGA UN STORAGE CON UN FIRMWARE NO SOPORTADO PUEDE CAUSAR INDISPONIBILIDAD AL EQUIPO STORAGEc)Abrir el archivo ArrayHosts.txt y escribir la IP de una de las controladoras del DS.d)Reiniciar el servicio cimserver
Nota:Las rutas varian según la versión de CIMOM:-10.50.G0.04 (Win): C:\Program Files\EngenioProvider\SMI_SProvider\bin-10.15.GG.07 (Win): C:\Program Files\lsi\pegasus\provider\array-10.19.GG.21 (Win): C:\Program Files\lsi\pegasus\provider\array
-10.15.GG.07 (AIX): /opt/lsi/pegasus/providers/array/
© 2010 IBM Corporation
18
Storage systems configuration detail
Configuration details in TPC server of following storage subsystems used on the demo platform :
SVC cluster Storwize V7000 DS5000 Switches Brocade
© 2010 IBM Corporation
19
Agregar un SVC al TPC
© 2010 IBM Corporation
20
“Configure Devices” wizard : Define an SVCUse existing uploaded key: This selection is the default. If you select this action, theAdmin Username and Admin Password fields are optional.
Upload new key:If you select this action, the Admin Username and Admin Passwordfields are required. Public key content is extracted from the private key that is provided in the Private SSH Key field and is uploaded to SAN Volume Controller or Storwize V7000.
Admin UsernameIf you selected Upload new key in the Select Key list, enter the name of a user who has the administrator role for the SAN Volume Controller or Storwize V7000 cluster
© 2010 IBM Corporation
21
“Configure Devices” wizard : Define an SVC
© 2010 IBM Corporation
22
“Configure Devices” wizard : Define an SVC
© 2010 IBM Corporation
23
“Configure Devices” wizard : Define an SVC
In the field Use a monitoring group or template, click the arrow and selectmonitoring group. When you include the SAN Volume Controller or StorwizeV7000 cluster in a monitoring group, Tivoli Storage Productivity Center managesthe cluster and a collection of other storage systems in the same manner.
In the field Select monitoring group, click the arrow and select SubsystemStandard Group.
© 2010 IBM Corporation
24
“Configure Devices” wizard : Define an SVC
© 2010 IBM Corporation
25
“Configure Devices” wizard : Define an SVC
© 2010 IBM Corporation
26
“Configure Devices” wizard : Define an SVC
© 2010 IBM Corporation
27
“Configure Devices” wizard : Define an SVC
© 2010 IBM Corporation
28
“Configure Devices” wizard : Define an SVC
Probe detail (log file)
© 2010 IBM Corporation
29
Agregar un Storwize al TPC
© 2010 IBM Corporation
30
“Configure Devices” wizard : Define a Storwize V7000
© 2010 IBM Corporation
31
“Configure Devices” wizard : Define a Storwize V7000
© 2010 IBM Corporation
32
“Configure Devices” wizard : Define a Storwize V7000
© 2010 IBM Corporation
33
“Configure Devices” wizard : Define a Storwize V7000
And then continue as for an SVC cluster
© 2010 IBM Corporation
34
Agregar un DS5000 al TPC
© 2010 IBM Corporation
35
“Configure Devices” wizard : Define DS5000
IP CIMON
© 2010 IBM Corporation
36
“Configure Devices” wizard : Define DS5000
© 2010 IBM Corporation
37
“Configure Devices” wizard : Define DS5000
© 2010 IBM Corporation
38
“Configure Devices” wizard : Define DS5000
© 2010 IBM Corporation
39
“Configure Devices” wizard : Define DS5000
© 2010 IBM Corporation
40
“Configure Devices” wizard : Define DS5000
© 2010 IBM Corporation
41
“Configure Devices” wizard : Define DS5000
© 2010 IBM Corporation
42
“Configure Devices” wizard : Define DS5000
© 2010 IBM Corporation
43
“Configure Devices” wizard : Define DS5000
© 2010 IBM Corporation
44
Switches definition
© 2010 IBM Corporation
45
Brocade Switches definition : define CIMOM
© 2010 IBM Corporation
46
Brocade Switches definition : define CIMOM
© 2010 IBM Corporation
47
Brocade Switches definition : CIMOM DiscoveryStart a CIMOM Discovery Job without option “Scan local subnet”
© 2010 IBM Corporation
48
Brocade Switches definition : Switches discovery
2 Brocade switches discovered by the CIMOM Discovery job
© 2010 IBM Corporation
49
Brocade Switches definition : Probe the Fabrics
© 2010 IBM Corporation
50
Brocade Switches definition : Probe log file
© 2010 IBM Corporation
Subir / Bajar servicios de TPC
51
© 2010 IBM Corporation
Subir servicios de TPC
Subir los servicios de TPC en el orden indicado a continuación (del 1 al 3). El detalle de cada punto se encuentra en los siguientes slides.
1.Subir la instancia db2inst1 de DB2
2.Subir el servicio de Data Server del TPC
3.Subir el servicio de Device Server del TPC
52
© 2010 IBM Corporation
Subir servicios de TPC – Instancia de DB2
Logearse al servidor de TPC AIX (129.39.178.94) via SSH
Pasar a modo sudo. Subir la instancia de la BD para ello ejecutar los
siguientes comandos:– > su – db2inst1
– > db2start
– > exit
53
© 2010 IBM Corporation
Subir servicios de TPC – Data Server / Device Server
Logearse al servidor de TPC AIX (129.39.178.94) via SSH
Pasar a modo sudo. Subir servicios del Data Server:
– > startsrc -s TSRMsrv1
– tpcdsrv1 start --- TPC 5: /opt/IBM/TPC/data/server/tpcdsrv1 start
Subir servicios del Device Server:– > /opt/IBM/TPC/device/bin/aix/startTPCF.sh
54
© 2010 IBM Corporation
Bajar servicios de TPC
Bajar los servicios de TPC en el orden indicado a continuación (del 1 al 2). El detalle de cada punto se encuentra en los siguientes slides.
1.Bajar el servicio de Device Server del TPC
2.Bajar el servicio de Data Server del TPC
55
© 2010 IBM Corporation
Bajar servicios de TPC – Data Server / Device Server
Logearse al servidor de TPC AIX (129.39.178.94) via SSH Pasar a modo sudo -su. Bajar servicios del Device Server:
– > /opt/IBM/TPC/device/bin/aix/stopTPCF.sh
●Verificar: ps -eaf | grep deviceServer Bajar servicios del Data Server:
– > stopsrc -s TSRMsrv1
– TPC 5 /opt/IBM/TPC/data/server/tpcdsrv1 stop
●Verificar: ps -eaf | grep DataServer.jar– Nota: En caso no bajar y aparece:*PRD* root@ibmtpc01> stopsrc -s TSRMsrv1
0513-006 The Subsystem, TSRMsrv1, is currently stopping its execution.
56
© 2010 IBM Corporation
57
EJECUTAR:
*PRD* root@ibmtpc01> ps -fea | grep TSRMsrv1
root 11403504 10289174 1 Aug 27 - 115:53 /opt/IBM/TPC/jre/java15/bin/java -DTivoliTSRM.servicePipe=/etc/Tivoli/TSRM/lock/TSRMsrv1 -Dsun.net.inetaddr.ttl=300 -Xmx1024m com.tivoli.itsrm.server.Server
*PRD* root@ibmtpc01> kill -9 11403504
*PRD* root@ibmtpc01> ps -fea | grep TSRMsrv1
root 11403506 5373954 0 10:19:56 pts/0 0:00 grep TSRMsrv1
*PRD* root@ibmtpc01> stopsrc -s TSRMsrv1
0513-004 The Subsystem or Group, TSRMsrv1, is currently inoperative.
© 2010 IBM Corporation
Bajar servicios WAS, TIP, SRA, TCR
/opt/IBM/TPC/agent/bin/agent.sh stop /opt/IBM/TPC/ewas/profiles/ReplicationServerProfile/bin/stopServer.sh
replicationServer /opt/IBM/tipv2/profiles/TIPProfile/bin/stopServer.sh server1 -username
db2inst1 -password P455w0rd /opt/IBM/tipv2Components/TCRComponent/bin/stopTCRserver.sh server1
db2inst1 P455w0rd /usr/ibm/common/acsi/bin/acsisrv.sh -stop
cd /opt/IBM/tipv2Components/TCRComponent/bin stopTCRserver.sh server1
58
© 2010 IBM Corporation
Subir servicios WAS, TIP, SRA, TCR
/opt/IBM/TPC/agent/bin/agent.sh start /opt/IBM/TPC/ewas/profiles/ReplicationServerProfile/bin/startServer.sh
replicationServer /opt/IBM/tipv2//profiles/TIPProfile/bin/startServer.sh server1 /opt/IBM/tipv2Components/TCRComponent/bin/startTCRserver.sh server1
cd /opt/IBM/tipv2Components/TCRComponent/bin startTCRserver.sh
59