4
Pre Galvanised Conduits Hot dip Galvanised Conduits HANGZHOU EVT ELECTRICAL CO., LTD. Steel conduit Conduit . Class 4 Hot dip galvanised inside and out Meets Class 4, heavy protection both inside and outside, as specified in BS 4568, BS 50086 and BS 61386. BS 4568 / BS EN 61386 – class 4 External Length Lengths Metres bundle bundle 20mm 25mm 32mm BS 4568 / BS EN 61386 – class 3 BSI Conduits & Fittings Class 3 External surface in line galvanised Meets Class 3 heavy protection outside as Class 4 and medium protection inside as Class 2, as specified in BS 4568, BS 50086 and BS 61386. Telephone: +86 (571)82452866 Fax: +86 (571)82351218 3750mm 3750mm 3750mm 20 15 10 per small per small 75 56.25 37.5 Wall Thickness Diameter 1.60mm 1.60mm 1.60mm External Length Lengths Metres bundle bundle 20mm 25mm 32mm 3750mm 3750mm 3750mm 20 15 10 per small per small 75 56.25 37.5 Wall Thickness Diameter 1.60mm 1.60mm 1.60mm Classes 1

Conduit Classes - EVT bs.pdf · Steel conduit Conduit. Class 4 Hot dip galvanised inside and out ... This family of standards is very similar to and is now replacing the BS EN 50086

Embed Size (px)

Citation preview

Page 1: Conduit Classes - EVT bs.pdf · Steel conduit Conduit. Class 4 Hot dip galvanised inside and out ... This family of standards is very similar to and is now replacing the BS EN 50086

Pre Galvanised Conduits

Hot dip Galvanised Conduits

HANGZHOU EVT ELECTRICAL CO., LTD.Steel conduit

Conduit

.

Class 4Hot dip galvanised inside and out

Meets Class 4, heavy protection both inside and outside, as specified in BS 4568, BS 50086 and BS 61386.

BS 4568 / BS EN 61386 – class 4

External

Length Lengths Metres

bundle bundle

20mm

25mm

32mm

BS 4568 / BS EN 61386 – class 3

BSI Conduits & Fittings

Class 3External surface in line galvanised

Meets Class 3 heavy protection outside as Class 4 and medium protection inside as Class 2, as specified in BS 4568, BS 50086 and BS 61386.

Telephone: +86 (571)82452866 Fax: +86 (571)82351218-

3750mm

3750mm

3750mm

20

15

10

per small per small

75

56.25

37.5

Wall ThicknessDiameter

1.60mm

1.60mm

1.60mm

External

Length

Lengths Metres bundle bundle

20mm

25mm

32mm

3750mm

3750mm

3750mm

20

15

10

per small per small

75

56.25

37.5

Wall ThicknessDiameter

1.60mm

1.60mm

1.60mm

Classes

1

Page 2: Conduit Classes - EVT bs.pdf · Steel conduit Conduit. Class 4 Hot dip galvanised inside and out ... This family of standards is very similar to and is now replacing the BS EN 50086

Covers

BSG

Gaskets

BSL

BS302B

BS301B

BS212B

BS211B

BS202B

BS201B

BS102B

BS101B

BS112

BS111

BS402EP

BS401EP

BS301EP

BS302EP

BS212EP

BS211EP

BS202EP

BS201EP

BS102EP

BS101EP

BS322

BS321

BS242

BS241

BS232

BS231

BS412

BS411

BS312

BS311

BS222

BS221

BS402

BS401

BS302

BS301

BS212

BS211

BS202

BS201

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

BS102

BS101

BSI Conduit & Fittings

Boxes (malleable)

Boxes (miscellaneous)

Galvanised terminal extension

Part no Size Per box

20mm

25mm

Galvanised through extension

Part no Size Per box

20mm

25mm

Galvanised angle extension

Part no Size Per box

20mm

Galvanised tee extension

Part no Size Per box

20mm

Galvanised tangent tee box

Part no Size Per box

20mm

25mm

Galvanised tangent angle

Part no Size Per box

20mm

25mm

Fittings

HANGZHOU EVT ELECTRICAL CO., LTD.

Telephone: +86 (571)82452866 Fax: +86 (571)82351218-

Galvanised Y box

Part no Size Per box

20mm

25mm

Galvanised H box

Part no Size Per box

20mm

Galvanised back outlet box

Part no Size Per box

20mm

Galvanised terminal and back outlet box

Part no Size Per box

20mm

25mm

Galvanised through and back outlet box

Part no Size Per box

20mm

25mm

Galvanised tee and back outlet box

Part no Size Per box

20mm

Galvanised angle and back outlet box

Part no Size Per box

20mm

Galvanised terminal box

Part no Size Per box

20mm

25mm

Galvanised through box

Part no Size Per box

20mm

25mm

Galvanised tee box

Part no Size Per box

20mm

25mm

Galvanised intersection box

Part no Size Per box

20mm

25mm

Galvanised angle box

Part no Size Per box

20mm

25mm

Galvanised U box

Part no Size Per box

20mm

25mm

10025mm

100

100

Galvanised tangent tee box

Part no Size Per box

20mm

25mm

100 25mm

100 25mm

100

Galvanised tee extension

Part no Size Per box

20mm

100 25mm

10025mm

100 25mm

100 25mm

Galvanised small box lids 2 hole – steel

Part no Per box

100

Galvanised small box lids 2 hole – steel

Part no Per box

100

2

Page 3: Conduit Classes - EVT bs.pdf · Steel conduit Conduit. Class 4 Hot dip galvanised inside and out ... This family of standards is very similar to and is now replacing the BS EN 50086

MU25-3

MU20-3

MU25-1

MU20-1

100

100

100

200

100

200

MU25

MU20

Inspection Tees

Inspection Elbows

Solid Bends

Inspection Lines (malleable)

Inspection Bends

250

500

1000

1000

BSR4

BSR3

BSR2

BSR1

FB3

FB2

FB1

1000

1500

2000

Brass Bushes Female

500

1000

2000

500

1000

2000

63-2L

62-2L

61-2L

63-2S

62-2S

61-2S

Long Bushes

Short Bushes

Brass Bushes Male

Galvanised Spacer Bar Saddles

Galvanised Distance Saddles

Nipples (steel)

BSA33

BSA32

BSA31

BSA23

BSA22

BSA21

Circle LocknutsHexagonal Locknuts

Flanged Couplers (malleable)

32mmX6

25mmX6

20mmX6

BSA13

BSA12

BSA11

32mmX3

25mmX3

20mmX3

BSA3

BSA2

BSA1

1000

1500

2000

U203U202UV201

U32U25U20

100150200

5005001000

200300400

BSNP3BSNP2BSNP1

1000

1000100

BSCP2

BSCP1

(Complete with BMMMLead Washer)

200

300

400

BSFC3

BSFC2

BSFC1

200

300

400

63-1

62-1

61-1

Solid Couplers

Fittings

Galvanised milled edge lockrings

Part no Size Per box

20mm

25mm

32mm

Part no Size Per box

20mm

25mm

32mm

Part no Size Per box

20mm

25mm

32mm

Galvanised flanged couplers

Part no Size Per box

20mm

25mm

32mm

Crampets (flat)

Galvanised crampets

Part no Size Per box

20mm

25mm

Galvanised steel nipples

Part no Size Per box

20mm 25mm 32mm

Saddles

Part no Size Per box

20mm 25mm 32mm

Part no Size Per box

20mm 25mm 32mm

Telephone: +86 (571)82452866 Fax: +86 (571)82351218-

BSI Conduit & Fittings

Galvanised light pattern locknuts

Part no Size Per box

1000

1500

2000

32mmX6

25mmX6

20mmX6

32mmX3

25mmX3

20mmX3

1000

1500

2000

Galvanised light pattern locknutsPart no Size Per box

1000

1500

2000

Female brass bush

Part no Size Per box

20mm

25mm

32mm

Reducers

Galvanised reducers

Part no Size Per box

20 x 16mm

25 x 20mm

32 x 20mm

32 x 25mm

Galvanised solid bend (steel)

Part no Size Per box

SBEN20G 20mm 25

SBEN25G 25mm 10

Part no Size Per box

20mm

25mm

Part no Size Per box

20mm

25mm

Part no Size Per box

20mm

25mm

HANGZHOU EVT ELECTRICAL CO., LTD.

3

Page 4: Conduit Classes - EVT bs.pdf · Steel conduit Conduit. Class 4 Hot dip galvanised inside and out ... This family of standards is very similar to and is now replacing the BS EN 50086

subsequent manufacturing processes.

Technical Notes

smooth and uniform finish with an excellent appearance.external bore of the Class 3 conduit tubes have a very(typical zinc thickness above 80 microns). The

and most cast products including circular conduit boxesClass 4 conduit tube (typical zinc thickness 50 microns)

significantly and may exceed 5 microns a year.

where necessary protected by zinc or paint coatings.

from appropriate grades of steel, malleable iron or brass,

Our BSI conduit fittings and conduit tubes are manufactured

and storage of the products.

These notes are intended to provide information and

guidance on standards, materials, finishes and the handling

We hope this section will assist stockists of our products,

their customers, including electrical contractors, and the

consultants responsible for preparing specifications. Please

contact us to seek further assistance or to raise any specific

queries you may have.

Materials and Finishes

Galvanised CoatingsUnprotected iron and steel will usually rust rapidly when

exposed to moisture and air. Zinc coatings prevent this

primarily by acting as a tough barrier between these metals

and the environment. Even if there is minor damage to the

galvanised coating then sacrificial erosion of the zinc will

continue to inhibit corrosion.

Rates of erosion of galavanised coatings reflect a number of

factors primarily the presence of moisture and atmospheric

pollutants such as sulphur dioxide (SO2). In warm dry

conditions loss of zinc may be less than 0.1 micron a year

but in coastal, marine or polluted environments this rises

It is important to understand the different types of zinc

coating available.

Hot dip galvanising after manufacture involves immersing

the article in molten zinc after all production processes,

other than tapping of threads, have been completed. It

provides the greatest amounts of protection and is used on

Pre-galvanised or mill galvanised steel is coated at the steel

mill by a hot dip process. Here the zinc coating thickness

is typically just under 20 microns and may be disrupted by

Zinc plated products have a much lower zinc thickness,

typically 7-8 microns which is applied electrolytically. It is

used to protect components such as fasteners and nipples

where other methods are not practical.

Storage of ConduitNewly galvanised articles have a bright, shiny surface finish

although this rapidly weathers to a matt dull appearance

as the protective patina develops. Ideally galvanised

products, in particular when newly galvanised should be

stored in warm dry conditions, preferably under cover. It

is important to prevent freshly galvanised steel becoming

wet, particularly if air is not free to circulate, since these

conditions lead to formation of a white powdery deposit

know as wet storage stain or white rust. Should this occur

the deposits can easily be removed by mild abrasion. The

reduction in the zinc coating thickness is rarely significant

and can be easily checked with an electronic thickness

gauge to confirm that the anticipated maintenance free

period remains adequate.

Standards

BS 4568 : Part 1 and Part 2 : 1970These national standards cover the supply of metric product including the most popular 20mm, 25mm and 32mm sizes and remain the best source of detailed dimensional information on these products. Part 2 includes ‘standards sheets’ which cover the main product groups. Top Tubes Electrical products comply with these sheets for example, small circular boxes sheet 4, large circular boxes sheet 5, distance saddles sheet 23.

BS EN 50086 SeriesThis ‘family’ of European standards was drawn up to cover conduit systems and was ultimately intended to replace national standards. They employ defined tests to cover measurement of parameters such as resistance to compression and impact strength with graded classifications which allow the standard to cover both metal products and plastic equivalents. It should be noted that many plastic equivalents to metal conduit systems are less strong, may be subject to more restricted temperature installation

typically exceed the performance required to meet the most stringent mechanical and strength tests. Resistance to corrosion tests remain virtually unchanged from those included in BS 4568.

BS EN 61386 SeriesThis family of standards is very similar to and is now replacing the BS EN 50086 series. They are intended to cover ‘Conduit Systems for Cable Management’ and their content is identical with the International standard IEC 61386.

and.standards

BSI Conduit & Fittings HANGZHOU EVT ELECTRICAL CO., LTD.

Telephone: +86 (571)82452866 Fax: +86 (571)82351218-

limits or could prove problematic under fire conditions. Our BSI conduit products

4