CONCIERGE 100PROFESSIONAL SERIESELECTRONIC DEADBOLT
USER GUIDE
IMPORTANT SAFETY INFORMATION 1TOOLS NEEDED FOR NEW INSTALLATION 2COMPONENTS OF ELECTRONIC KEYPAD DEADBOLT 3DOOR PREPARATION 4 - 7INSTALLATION 8 - 13OVERVIEW OF FUNCTIONS 14KEYPAD LIGHTS & WARNINGS 15CODES INFORMATION 16PROGRAMMING 1.AUTOMATICBOLTDIRECTIONADJUSTMENT 17 2.CHANGEPROGRAMMINGCODE 18 3.ADD/DELETEUSERENTRYCODE 19 4.DELETEALLUSERENTRYCODESATONCE 20 5.TEMPORARILYDISABLEALLUSERCODES 21 6.CREATEADISPOSABLEUSERENTRYCODE 22 7.“AUTOLOCK”FUNCTION 23 8.MUTEON/OFF 24 9.RESTOREFACTORYSETTING 25OPERATION 26 - 27TROUBLESHOOTING GUIDE 28 - 29 INFORMATION PAGE 30 WARRANTY 31
CONTENTS
IMPORTANT SAFETY INFORMATION
! WARNING1. Donotuseanyabrasivesoranychemicalproductscontaininganysubstanceofalcohol,benzene,
hydrochloricacidornitricacid,andavoidsharporscratchingobjectstocleanthislockset.2. Donotletanywaterorliquidintolocksetduringinstallationprocess.
! IMPORTANT SAFETY INSTRUCTION1. Donotattempttodisassembleanyinternalcomponentsofthelocksetpersonally.Youmayrunthe
riskofvoidingthelimitedwarranty.2. Donotdroporhitthelockset.3. Donotusesharpobjectstopresskeybuttons.4. Alwayscreateabackupofinformationyouwanttokeep(suchasprogrammingcodeanduse
codes).Pleaseusethelastpageofthisbookletasyourreference.5. Pleasechangeprogrammingcodebeforeoperatingthislockset.
! CARE AND MAINTENANCEThe following care instructions should be followed to ensure a long lasting finish:1. Removelocks,ordonotinstalllocks,priortopaintingyourdoor.2. Periodicallycleanwithmildsoapandasoftclothonly.
®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.1
• PENCIL• CHISEL• TAPEMEASURE• HAMMER• PHILLIPSSCREWDRIVER• 1”(25mm)&1/8”(3mm)DRILLBITS• 2-1/8”(54mm)HOLEBORINGKIT• POWERDRILL• 2”(51mm)6DCOMMONNAIL• 4-AA1.5VALKALINEBATTERIES
TOOLS NEEDED FOR NEW INSTALLATION
2 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.
®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.3
COMPONENTS OF ELECTRONIC KEYPAD DEADBOLT
INTERIORBATTERYCOVER
WOODSCREWS
METALSCREWS
MOUNTINGBOLTS
MOUNTINGPLATE
INTERIORASSEMBLY
WOODSCREWS
LATCHRUBBERGASKET
CYLINDERTORQUEBLADE
CYLINDEREXTERIORASSEMBLY
ICWIRE
4 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.
TEMPLATE
CENTERLINE
MARKDOOREDGEAPPROXIMATELY3”TO6”(75mmTO150mm)ABOVETHEENTRYKNOBORLEVER
DOOR PREPARATION1 MARK DOOR WITH TEMPLATE (ATTACHED SEPARATELY)
Note: If replacing an existing lock or installing in a pre-drilled door, begin with page 8. a. UseTEMPLATEtomarkcenterlineondoorfordeadboltabout3”to6”(75mmto150mm)above theexistingknoborlever. b. Standsodoorswingstowardsyou.Aligntemplateoncenterlineandfoldtemplateasshown.
CENTERLINE
BACKSET
DRILL1/8”(3mm)PILOTHOLE
1”(25mm)
2-1/8” (54mm)
DRILL1/8”(3mm)PILOTHOLE
®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.5
DOOR PREPARATION
2 MARK AND DRILL PILOT HOLES Selectbackset.Markanddrillpilotholes asshown.
6 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.
DOOR PREPARATION
3 USING THE TEMPLATE MARKS AS A GUIDE a. Drilla2-1/8”(54mm)holeonthedoorfacefrombothsidestopreventwoodfromsplitting. b. Drilla1”(25mm)holeinthedooredgeforthelatch. c. Usethelatchfaceplateasapatternforthemortiseandpilotholes.Chisel1/8”(3mm)deep. Faceplateshouldfitflush. Note: for drive-in latch, simply insert latch.
a. b. c.
2-1/8”(54mm)
1”(25mm)
FACEPLATE
OUTLINE
CHISEL1/8”(3mm)DEEP
®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.7
DOOR PREPARATION
4 PREPARE DOOR JAMB AND INSTALL STRIKE PLATE a. Toidentifythecenterofthestrike:insertthelatch,closethedoor; usingthelatchfaceplateasaguide,markhorizontalcenterlineand outlineofthestrike.Ensurethecenterofthefaceplateandthe centerofthestrikearealigned. b. Chisel5/64”(2mm)deepalongthestrikeoutlinetoallowthestrike tobealignedwiththedoorframe. c. Insertthestrikeandtightenitwithwoodscrews.
Door jamb hole dimension a. 1-3/16(30mm) b. 1-3/8”(35mm) c. 1”(25mm)
Strike dimension d. 9/32”(7mm) e. 2-15/16”(75mm) f. 1-5/16”(33mm)
a.
b.
c.
A
B
C
D
E
F
8 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.
INSTALLATION 6 WAY LATCH
1 6 WAY LATCH To Change Latch Faces1. Useaflat-headscrewdrivertoseparate
thefaceplateformthebackplate.2. Snaptheselectedfaceplateontothe
backplate.
Latch Backset AdjustmentTorotatethelatchcaseasfollowingillustrationforbackset2-3/4”(70mm)orreversedirectionfor2-3/8”(60mm)
Drive-in InstallationMakesuretheroundfaceplateisproperlyalignedasillustratedandsnapittothelatchcase. DRIVE-INLATCH
2-3/4”(70mm)
1B
®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.9
INSTALLATION
2 INSTALL LATCH IN MORTISED AREA OR DRIVE-IN LATCH Ifyourdoorissetuptouseastandardtypelatch,pleaseinstallitwiththe3/4”(20mm)screws thatareprovided.Ifyouusethedrive-inlatch,pleasetapitintoplace.
BACKSET
FACEPLATE
3/4”(20mm)WOODSCREWS
OR
DRIVE-INLATCH TAPLATCHFLUSH
WOODBLOCK(NOTINCLUDED)
10 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.
INSTALLATION
3 a. Makesurelatchisinretractedposition. b. Insertthecylinderintoexteriorassemblywithcylindertorquebladeinsertedthroughhubofthe latchinahorizontalposition. c. PasstheICwireunderthelatchtotheinteriorsideofthedoor.
a. b. c.
ICWIRE
®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.11
INSTALLATION
4 INSTALL INSIDE THE MOUNTING PLATE a. CarefullypasstheICwirethroughthewirehole onthemountingplate. b. Makingsurethattheexteriorassemblyand cylinderarepressedflushagainsttheexterior door,insertthemountingboltsandtighten. c. Checktheverticalalignmentforthemounting plateandexteriorassembly. d. Test.Usingthekey,retractandextendthebolt afewtimestotestforsmoothaction. e. Ifactionfeelsrough,loosenscrewsandrealign themountingplateandexteriorassembly.
KEEPPARALLEL
MOUNTINGPLATE
MOUNTINGBOLTS
ICWIRE
12 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.
INSTALLATION - DOOR HANDING
5 IDENTIFY THE DOOR HANDING a. Facethedoorfrominside b. Thedooris“left-handed”ifthehingesareonthelefthandsideofthedoor. c. Thedooris“right-handed”ifthehingesareontherighthandsideofthedoor.
6 ADJUST INTERIOR TURN PIECE a. Turntheturnpiecetotheleftwhenitisa“right-handed”door. b. Turntheturnpiecetotherightwhenitisa“left-handed”door.
LEFT-HANDED RIGHT-HANDED
INTERIOR
EXTERIOR
HINGEDOOR
®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.13
INSTALLATION - RECEIVER MODULE
7 INSTALL RECEIVER MODULE a. Removethebatterycover(pushitupandpullitout). b. ConnecttheICwiresandensurethecylindertorquebladeisengagedwiththeturnpiecethen attachtheinteriorassemblytothedoorwiththemetalscrews. c. Insert4(AA)1.5Valkalinebatteriesandplacethecoverbackontotheinteriorassembly.
BATTERYCOVER
METALSCREWS
WOODSCREWS
a. b. c.
14 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.
OVERVIEW OF FUNCTIONS
1. PROGRAMMING BUTTON ProgrammingButtonisforenteringcodes, clearingerrors,andsettingfunctions. It’salsoa“Lock”Button.2. KEYPAD WITH NUMBER BUTTONS Forinputtingcodes,4-10digitsinlength.3. CYLINDER Retract/Expandlatchboltbykeyfromoutside.4. RUBBER GASKET Topreventwaterleakingthrough exteriorassembly.5. BATTERY COVER6. BATTERY HUB Four(AA)AlkalineBatteries (soldseparately)7. “R” BUTTON (RESET) Restoredefaultsetting8. TURN PIECE Retract/Expandthelatchbolt frominside.
1
2
3
4
6
7
8
5
®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.15
KEYPAD LIGHTS & WARNINGS
LED INDICATOR LIGHT1. Flashes“Green”oncewhenoperatingfunctionisperformedproperly.2. Flashes“Green”twicewhenprogrammingfunctionisperformedproperly.3. Flashes“Red”threetimeswhenoperatingfunctionwasnotperformedproperly.4. Flashes“Red”fivetimesfollowingfiveunauthorizedentryattempts-thekeypadwillbedisabledfor
45seconds.5. Flashes“Orange”threetimeswhensystemwasrestoredtodefaultsetting.6. Flashes“Orange”slowlywhileinprogrammingmode.
AUDIO WARNINGS1. One“Beep”-operatingfunctionwasperformedproperly.2. Two“Beeps”-programmingfunctionwasperformedproperly.3. Three“Beeps”-operatingfunctionwasnotperformedproperly.
LOW BATTERY WARNINGLEDindicatorflashes“Red”andconstant“Beep”soundisonfor10seconds.Pleasereplacebatteries.
Note: • The lock can still be operated via regular key. • All settings are stored in the memory and will not be affected even when the batteries are replaced.
16 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.
CODE INFORMATION
PROGRAMMING CODE1. Programmingcodeprovidesabilitytoprogram/reprogramthedeadbolt,andchange/delete/add
individualusercodes.2. Programmingcodecannotbeusedtounlockthedeadbolt.3. Onlyoneprogrammingcodeisallowed,4-10digitsinlength.4. Thefactorypresetprogrammingcodeis0-0-0-0,andcanbechangedanytimeifneeded.
USER ENTRY CODE1. Userentrycodeallowstheindividualusertolockandunlockthedeadbolt.2. Thefactorypresetuserentrycodeis1-2-3-4.Pleasedeleteitandcreateyourpersonal,uniqueuser
entrycodeassoonasthedeadboltisinstalled.3. Userentrycodecanbe4-10digitsinlength.4. Maximumof6userentrycodescanbeprogrammedintoonedeadbolt.5. Anindividualuserentrycodecanbechanged/deleted/addedtothelocksetonlybyusingavalid
programmingcode.
®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.17
PROGRAMMING
AUTOMATIC BOLT DIRECTION ADJUSTMENT
Deadboltthrowdirectionisautomaticallyadjustedtoleftorright-handeddoor.
1. Deadboltshouldbeinunlockedposition.2. Makesuretheinteriorthumbturnpositionisidentifiedproperlyaccordingtodoorhanding. (seepage12).
FUNCTION STEPS
DetectLeft/RightHandDoorInstallation
EnterProgramming
Code
Press“0”
18 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.
PROGRAMMING
CHANGE PROGRAMMING CODE
IMPORTANT: The factory preset programming code is 0-0-0-0 and needs to be changed to a unique6 digit number before operating the deadbolt.
1. Deadboltshouldbeinunlockedposition.2. LEDindicatorflashes“Orange”whileinprogrammingmode.LEDindicatorflashes“Green”twice
with2long“Beeps”whenprogrammingfunctionisperformedcorrectly.LEDindicatorlightflashesthreetimeswiththree“Beeps”whenprogrammingfunctionisperformedincorrectly.
Note: wait for at least 6 seconds or press and repeat programming steps if programming error was committed.
3. Everyprogrammingstepshouldbeperformedin6secondsorless.
FUNCTION STEPSChange
ProgrammingCode
EnterProgramming
Code
Press“4”
EnterProgramming
Code
®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.19
PROGRAMMING
ADD/DELETE USER ENTRY CODE
1. Userentrycodescanbedeletedindividually.Youcanreusethesamenumberasacodeevenifitwasdeletedbefore.
2. Thefactorypresetuserentrycodeis1-2-3-4.Pleasedeleteitandcreateyourpersonaluniqueuserentrycodeoncethedeadboltisinstalled.
FUNCTION STEPS
AddNewUserEntryCode
EnterProgramming
Code
Press“1”
EnterNewUserEntry
Code
DeleteExistingUserEntryCode
EnterProgramming
Code
Press“2”
EnterUserEntryCodeyouwanttodelete
20 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.
PROGRAMMING
DELETE ALL USER ENTRY CODES AT ONCE
1. Alluserentrycodescanbedeletedatonce.Youcanstillreusethesamenumbersasnewcodeseveniftheyhavebeendeletedbefore.
2. “Auto-Lock”and“KeypadLock”functionswillbeinvalidafterdeletingalluserentryuserentrycodes,andthedeadboltcanonlybeoperatedbyregularkey.Thefunctionswillberestoredwhenthenewuserentrycodesarecreated.
FUNCTION STEPS
DeleteallUserEntryCodesatonce
EnterProgramming
Code
Press“3”
®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.21
PROGRAMMING
TEMPORARILY DISABLE ALL USER CODES
1. “Auto-Lock”and“KeypadLock”functionswillbeinvalidwhenalluserentrycodesaretemporarilydisabled.Thedeadboltcanonlybeoperatedbyregularkeyatthistime.
2. Repeattheprogrammingstepstorestorealluserentrycodes.
FUNCTION STEPS
Disable/EnableallUserEntryCodes
EnterProgramming
Code
Press“8”
22 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.
PROGRAMMING
CREATE A DISPOSABLE USER ENTRY CODE
1. Disposableentrycodecanonlybeusedonce.2. Youcanreusethesamenumberasadisposableuserentrycodeagain.
FUNCTION STEPSCreate
DisposableUserEntryCode
EnterProgramming
Code
Press“9”
EnterNewDisposableEntrlyCode
®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.23
PROGRAMMING
“AUTO-LOCK” FUNCTION
1. Thedoorwillbeautomaticallylockedwithin10to99secondswhen“Auto-Lock”functionisenabled.2. Thedeadboltcomeswith“Auto-Lock”functiondisabledfromthefactory.3. “Auto-Lock”timedelayispresetto30seconds.Itcanbeadjustedto10to99secondsifneeded.4. Thesystemwillsignalanoperatingerrorifthedeadboltfailstolatchproperly.Re-entervaliduser
entrycodetounlockthedoorandretractthelatchbolt.“Auto-Lock”functionisnowrestored.
FUNCTION STEPS
Auto-LockON/OFF
EnterProgramming
Code
Press“5”
Auto-LockTimeDelay
EnterProgramming
Code
Press“6”
EnterSeconds(10to99)
24 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.
PROGRAMMING
MUTE ON/OFF
1. Audible“Beep”alertswhenpressingkeypadbuttons,duringprogrammingoroperatingerrors,canbeturnedoffifneeded.
2. LEDindicatorlightwillstillfunctionwhenmuted.3. Motoroperatingsoundcannotbemuted.
FUNCTION STEPS
MuteON/OFF
EnterProgramming
Code
Press“7”
®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.25
PROGRAMMING
RESTORE FACTORY SETTING
1. Removebatterycoverandlocate“R”button.2. Press“R”buttonforatleast5secondsuntilyouhearthreelong“Beeps”.3. Thedeadboltisnowresetbacktothefactorysetting: -programmingcode0-0-0-0 -userentrycode1-2-3-44. Repeatautomaticboltdirectionadjustment(seepage17)beforeyouproceedtoprogrammingany
otherfunctinintothedeadbolt.
26 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.
OPERATION
LOCK OPERATION
TO LOCK1. Press oruseregularkeytolockthedeadboltfromoutside.2. Turnthumbturnpiecetolockthedeadboltfrominside.
TO UNLOCK1. Entervaliduserentrycodeandpress ,oruseregularkeytounlockthedeadboltfromthe
outside.2. Turnthumbturnpiecetounlockthedeadboltfromtheinside.
®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.27
OPERATION
SECURITY MODE
1. Thekeypadwillbeautomaticallydeactivatedfor45secondsafter5unauthorizedentryattempts.2. Thedeadboltcanbelockedandunlockedbytheregularkeyundersecuritymode.
28 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.
QUESTIONS ANSWERS
A.I’mnotabletochangetheprogrammingcode.
1.Makesurethateveryprogrammingstepiscompletedinunder6seconds.
B.Whattypeofbatteriesdoyourecommend?
1.Forbestresults,pleaseusenewnon-rechargeablealkalinebatter-ies.(4-AA1.5V)
C.Howlongwillthelockoperateononesetofbatteries?
1.Basedon15operationsperday,asinglesetofalkalinebatterieswilloperatethelocksetforoverayear.
TROUBLESHOOTING GUIDE - INSTALLATION
QUESTIONS ANSWERS
A.Ijustcompletedtheinstallation,butamunabletooperateitmanually.WhatshouldIdo?
1.Checkthealignmentbetweenthestrikeholeandthelatchtoensurethereisunobstructedmovementofthelatchbolt.
2.Makesurethetorquebladeisproperlyinsertedintothelatchhubinahorizontalposition.
3.RepeattheAutomaticBoltDirectionroutine(seepage17).
B.SometimeswhenIoperatethelock
manuallyI“feel”abumpwhileturningthethumbturnorkey.
1.Theelectromechanicalcomponentsofthelocksetareoutofsync.Tore-synchronizethesystemplease“lock”andthen“unlock”thedeadboltusingthekeypad.
C.Inampressinganybuttononthekeypadanditdoesn’tseemtorespondatall.
1.Checktoseeifthebatteriesareproperlyinstalled.2.Re-installnewbatteriesifthe“LowBatteryWarning”ison.3.CheckforproperconnectionbetweentheICwires.
®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.29
TROUBLESHOOTING GUIDE - OPERATION
QUESTIONS ANSWERS
A.I’mnotabletochangetheprogrammingcode.
1.Makesurethateveryprogrammingstepiscompletedinunder6seconds.
B.Whattypeofbatteriesdoyourecommend?
1.Forbestresults,pleaseusenewnon-rechargeablealkalinebatter-ies.(4-AA1.5V)
C.Howlongwillthelockoperateononesetofbatteries?
1.Basedon15operationsperday,asinglesetofalkalinebatterieswilloperatethelocksetforoverayear.
30 ®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.
INFORMATION PAGE
NAME USER CODE
IMPORTANT NOTE:1. Donotshareyourprogrammingcodewithanyoneelse.2. Keepawrittencopyofallvalidusercodesinasafeplace.(Youmayusethetablebelowtorecord
yourinformation)3. Youareadvisedtore-programallcodesifyoulostanysecurityinformationinthetable.
PROGRAMMING CODE
Taymor’s CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT is manufacturedunderthehigheststandardsofqualityandworkmanship.TaymorLocksarewarrantedtobefreefromfinishdefectsfor5(five)yearsandfreefrommechanical,materialandworkmanshipdefectstotheoriginalconsumerpurchaserforthelifeoftheproductaslongastheoriginalownerownshis/herhome.Taymorwillreplacefreeofcharge,duringthewarrantyperiod,anypart that fails tomeet thewarrantyundernormal installationanduseas longas theproducthasbeencaredforaccordingtothecareinstructionslistedinthepackageandonthewebsite.Electroniccomponentsofthislockarelimitedto1(one)yearfromthedateofpurchase.
Formoredetailssee www.taymor.com
CONCIERGE 100PROFESSIONAL SERIESELECTRONIC DEADBOLT
WARRANTY
®REGISTEREDTRADEMARKOFTAYMORINDUSTRIESLTD.31