Concept and results for a new kind of portable SMPS + C system (Sequential Mobility Particle Sizer + Counter) Christian GERHART 1 , Hans GRIMM 1 and Mathias RICHTER 2 1 GRIMM AEROSOL Technik GmbH, Dorfstrasse 9, D-83404 Ainring, Germany. 2 G.I.P GmbH, Research Department, Mühlbecker Weg 38,0671 Pouch, Germany. INTRODUCTION Concept and results for a new kind of portable nucleous condensation counter and classifier are presented. This new family of portable real time SEQUENTIAL MOBILITY PARTICLE SIZER and COUNTER (SMPS+C) is designed for mobility and easy setup for laboratory and field use. An integrated battery assures hours of operation, a data logger system storage of all optioned results and a user friendly powerful software easy operation. This technology not only simplifies the SMPS operation, but it permits new on site or on board applications up to a remote wireless telephone operation. COUNTER CONCEPT Instead of using several individual components combining to an operational system, all necessary items and appropriate functions have been combined into one portable system. This means the well known principle of “Nucleus Condensation Counting” was improved in such a way that: 1. an integrated air and DMA control system permits the attachment of any of Grimm classifiers, reducing not only the overall size, but also handling and system manipulation, 2. an integrated microprocessor system permits the operation of the complete system without an attached computer, status lights and a digital display show the measurement conditions, 3. the alcohol saturation chamber gets only as much alcohol from the integrated tank as needed, eliminating possible spill into the optic – an automatic refill system for external alcohol tanks assures long term operation, 4. a new moisture elimination system assures long reliable field measurements even at a high humidity in the sample air – alcohol exchange is not required, 5. the sample outlet air has an alcohol odor adsorber, 6. an additional port permits the attachment of external gas and/or climatic sensors, helping a better judgement of the sampling and measurement data obtained, 7. measurement, instrument and sensor data of up to ½ year can be stored on a removable data storage card, 8. the single counter and even the complete SMPS+C system can be operated remotely via a telephone modem, 9. an internal heat exchange system reduces drastically the electric power consumption, permitting hours of continuous operation with the integrated lead battery. Table 1. Performance of the Particle Counter Parameter Range Min. particle size in [nm] (50%) 4.5 Max. concentration [P/l] 10 10 Count Rate [P/l] 10 7 Sample flow rate [l/min] 0.3 or 1.5

Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Concept and results for a new kind of portable SMPS + C system (Sequential Mobility Particle Sizer + Counter)

Christian GERHART1, Hans GRIMM1 and Mathias RICHTER2

1 GRIMM AEROSOL Technik GmbH, Dorfstrasse 9, D-83404 Ainring, Germany. 2 G.I.P GmbH, Research Department, Mühlbecker Weg 38,0671 Pouch, Germany.

INTRODUCTION Concept and results for a new kind of portable nucleous condensation counter and classifier are presented. This new family of portable real time SEQUENTIAL MOBILITY PARTICLE SIZER and COUNTER (SMPS+C) is designed for mobility and easy setup for laboratory and field use. An integrated battery assures hours of operation, a data logger system storage of all optioned results and a user friendly powerful software easy operation. This technology not only simplifies the SMPS operation, but it permits new on site or on board applications up to a remote wireless telephone operation.

COUNTER CONCEPT Instead of using several individual components combining to an operational system, all necessary items and appropriate functions have been combined into one portable system. This means the well known principle of “Nucleus Condensation Counting” was improved in such a way that:

1. an integrated air and DMA control system permits the attachment of any of Grimm classifiers, reducing not only the overall size, but also handling and system manipulation,

2. an integrated microprocessor system permits the operation of the complete system without an attached computer, status lights and a digital display show the measurement conditions,

3. the alcohol saturation chamber gets only as much alcohol from the integrated tank as needed, eliminating possible spill into the optic – an automatic refill system for external alcohol tanks assures long term operation,

4. a new moisture elimination system assures long reliable field measurements even at a high humidity in the sample air – alcohol exchange is not required,

5. the sample outlet air has an alcohol odor adsorber, 6. an additional port permits the attachment of external gas and/or climatic sensors,

helping a better judgement of the sampling and measurement data obtained, 7. measurement, instrument and sensor data of up to ½ year can be stored on a

removable data storage card, 8. the single counter and even the complete SMPS+C system can be operated remotely

via a telephone modem, 9. an internal heat exchange system reduces drastically the electric power consumption,

permitting hours of continuous operation with the integrated lead battery.

Table 1. Performance of the Particle Counter Parameter Range Min. particle size in [nm] (50%) 4.5 Max. concentration [P/l] 1010

Count Rate [P/l] 107

Sample flow rate [l/min] 0.3 or 1.5

Page 2: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

CLASSIFIER CONCEPT Any of the tree Grimm column classifiers are completely controled by the counter unit. Sheath air and sample air flow are supplied by the counter. The flows are controlled and monitored inside the counter with the internal microcontroller unit. For the user it is not any more possible to manipulate the flows which is very important for the reproducebility, intercomparison of different grimm SMPS+C systems and the relieability of the results. Table 2: Parameter of Grimm DMA classifier

Model: Small Medium Long Range [nm] 3 –150 7 – 350 17 – 875 Min. scan speed [s] * < 30 < 50 < 100 Particles Solids and non volatile droplets Sample air [l/min] 0.3 0.3 0.3 Sheath air [l/min] 3.0 3.0 3.0 Sheath air supply From counter Impactor Integrated and exchangeable Neutralizer Am-241 source in stainless steel housing Classifier Stainless steel Length [cm] 12.5 (5inch) 38 (15inch) 63 (25inch) Diameter of cylinder [cm] 8 (2.8inch) Weight [kg] 3.4 4.5 7.8 Power supply None, via counter *Prescan mode

SOFTWARE AND DATA REDUCTION CONCEPT The 32-bit software includes the comunication module to the SMPS+C system for setting the measurement parameters and for resolving the measured data. The raw data is immediately calculated by transfer algorithm for data reduction and presented in a grafic module. An integrated satistic module summarizes the results in several parameters of a particle size distribution like mean, mode, logN-fit parameter etc. The Grimm SMPS+C system uses the stepping technology for a clear data reduction method. Different types of sequencing/stepping techniques in the software are available:

• the normal measurement mode (~ 3 – 6 min) • fast mode (~ 1,5 – 3 min) • prescan mode (<1 – 1,5 min)

depending on the DMA length. The data reduction method for the Grimm SMPS+C is developed and built up at the University of Vienna (Reischl). The calculations include the transferfunction of the Grimm classifiers, the Fuchs theory and all required geometric and time-dependent parameters. The system is validated in comparison with a reference system for aerosol size measurement < 1000 nm described by Winklmayr, et al. 1990.

CONCLUSIONS With the Grimm SMPS+C a new generation of field and laboratory particle sizer and counter was built up. Focused on mobility, ruggedness and stand alone operation an up-to-date compact high-tech concept for reliable and reproducible results. With this complete mobile and portable system for the first time field tests even under rough treatment got possible – the construction of the system allows measurements during cross-country trips and flights in aeroplanes.The application ranges from climate research, workplace and medical studies to emission investigations such as exhaust gas and filter-efficiency tests.

Page 3: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Concept and results for a new kind of Concept and results for a new kind of portable SMPS + C systemportable SMPS + C system((SSequentialequential MMobilityobility PParticlearticle SSizerizer + + CCounterounter))

Page 4: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 2

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system

ContentsContents

1. 1. CounterCounter conceptconcept2. 2. Classifier conceptClassifier concept3. Software 3. Software conceptconcept4. 4. SummarySummary

Page 5: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 3

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system1. Counter Concept

-Mobility-

••Pumps + Pumps + control integratedcontrol integrated

•Integrated alcohol tank

•Alcohol only in saturated fleece

•H2O-drain off

•Battery operated

Page 6: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 4

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system

Alcohol Tank

Air-Flow Pumps

Intelligence + Memory

Condensate Exit

Heating/Cooling

Saturator/Condenser

fleece inside

1. Counter Concept-Mobility-

Page 7: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 5

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system1. Counter Concept

-Mobility-

•Pumps + control integrated

••Integrated alcoholIntegrated alcohol tanktank

••Alcohol onlyAlcohol only inin saturated fleecesaturated fleece

•H2O-drain off

•Battery operated

Page 8: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 6

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system1. Counter Concept

-Mobility-

Problem I : Problem I : alcohol spill alcohol spill and and odorodor Active CarbonFilter

Cond

ense

r 10°

C- Due to mobility alcohol spill possible into the optic

- Integrated alcohol tank with- automatic feeding and - level control system - and refill automatic

Saturator 35°C

Page 9: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 7

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system1. Counter Concept

-Mobility-

•Pumps + control integrated

•Integrated alcohol tank

•Alcohol only in saturated fleece

••HH22OO--draindrain offoff

•Battery operated

Page 10: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 8

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system1. Counter Concept

-Mobility-

Problem II : Problem II : condensation condensation of ambient of ambient humidityhumidityin in the condenserthe condenser

-condensated water in the alcohol reducescount-efficiency Saturator 35°C

Cond

ense

r 10°

C

Automatic Micropump

-long-term environmentalmonitoring without efficiency loss

Page 11: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 9

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system

ContentsContents

1. 1. CounterCounter conceptconcept2. 2. Classifier conceptClassifier concept3. Software 3. Software conceptconcept4. Outlook /4. Outlook / SummarySummary

Page 12: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 10

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system2. Classifier Concept

-Design-Differential mobility analyzer

Large: 15 - 900 nm

Medium: 7 - 340 nm

Small: 5 - 100 nm

Page 13: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 11

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system

Integrated high-voltage power supply(power and control -16bit- by counter)

Interchangeable impactor nozzles (sample inlet)

Sheath air from counter

Sample flow to counter

Neutralizer: Am-241 source attachable

Differential mobility analyzer

2. Classifier Concept-Design-

Page 14: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 12

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system

ContentsContents

1. 1. CounterCounter conceptconcept2. 2. Classifier conceptClassifier concept3. Software 3. Software conceptconcept4. Outlook /4. Outlook / SummarySummary

Page 15: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 13

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system

32-bit software for counter and complete SMPS+C systems32-bit software for counter and complete SMPS+C systems

•Setup of parameters•Zero test with classifier•Immediate result presentation withconversion calculations

•Data transfer by pcmcia•Schedule and alarm management

•Data presentation: frequency, cumulative distribution, number, ...., volume (mass), etc.

•Statistical analysis: modes, deviations, etc.

•Data fitting (logN, RRSB, mulitmodal)

•Data export (ASCII, MS-Excel)

3. Software Concept-Features-

Page 16: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 14

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system

Data Inversion:(Number Size Distribution Function)

with: α(dP,i) = station. charging state (Fuchs, 1963)Tr(Z) = transfer function of DMAF(dP) = orig. number size distribution

Solved only if:•Knowledge on DMA Tr(Z)•Knowledge on charge distribution α(dP,i)•Limited upper particle size (impactor => < 900 nm)•Fixed voltage steps / mobility channels

∑∞

=

⋅⋅=1

)()(),()(i

PPPC dFZTriddF α

by REISCHL (1991)Only with a sequential stepping method and well defined delay timesof the respective DMA and the counter is the calculation back to the

original input aerosol size distribution possible.

Only with a sequential stepping method and well defined delay timesof the respective DMA and the counter is the calculation back to the

original input aerosol size distribution possible.

3. Software Concept-Calculation-

Page 17: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 15

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system

dP [nm]10 100 1000

dN /

dlgd

P [1

/cm

3 ]

0

1e+5

2e+5

3e+5

4e+5

5e+5

6e+5

NORMAL

dP [nm]10 100 1000

dN /

dlgd

P [1

/cm

3 ]

0

1e+5

2e+5

3e+5

4e+5

5e+5

6e+5

NORMALFAST

• normal mode (~ 3 – 6 min)

• fast mode(~ 1,5 – 3 min)

• prescan mode (<1 – 1,5 min)

depending on the DMA length

3. Software Concept-Results-

Page 18: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 16

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system

dP [nm]10 100 1000

dN /

dlnd

P [1

/cm

3 ]

0

1000

2000

3000

4000

5000

6000

7000

8000

NORMAL• normal mode

(~ 3 – 6 min)

• fast mode(~ 1,5 – 3 min)

• prescan mode (<1 – 1,5 min)

depending on the DMA lengthdP [nm]

10 100 1000

dN /

dlnd

P [1/

cm3 ]

0

1000

2000

3000

4000

5000

6000

7000

8000

NORMALFAST

3. Software Concept-Results-

Page 19: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 17

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system

ContentsContents

1. 1. CounterCounter conceptconcept2. 2. Classifier conceptClassifier concept3. Software 3. Software conceptconcept4. 4. SummarySummary

Page 20: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 18

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system4. Summary

•• no no free liquidsfree liquids, no, no spillspill -- saturator with fleecesaturator with fleece

•• very compactvery compact allall--inin--oneone designdesign

•• controlcontrol andand supplysupply of DMA of DMA integratedintegrated

•• HH22O O condensation outletcondensation outlet && data storagedata storage

cards for longcards for long time time measurementsmeasurements

•• remote control by telephoneremote control by telephone

•• stepping for clear data reductionstepping for clear data reduction

Page 21: Concept and results for a new kind of ... - ETH Conference · 6th International ETH-Conference on Nanoparticle Measurement – 2002 Dr. Christian Gerhart 6. Concept and results for

Grimm Aerosol Technik GmbH & Co. KGGrimm Aerosol Technik GmbH & Co. KG6th International ETH-Conference onNanoparticle Measurement – 2002

Dr. Christian Gerhart 19

ConceptConcept andand results forresults for aa new kindnew kind of portable SMPS + C systemof portable SMPS + C system

ENDEND