Upload
lamhanh
View
214
Download
0
Embed Size (px)
Citation preview
WHAT IS COMSLAB®?
-- A Combination of embossed, deep steel deck, concrete cover slab and one-way rebar that have cured together and bonded structurally to act as one element to provide slab reinforcement --
2-3” Bearing
Mid-Rise Residential
PRIMARY USES
High-Rise Residential
Mezzanines Multi-Level Storage
Building Re-Purpose
Hotels
Education Buildings
Long Span Deep Steel Deck bearing on L/B Steel Studs, Structural Steel, Concrete, Wood, ICF & Tilt up walls.
Loadbearing Cold-Form Steel Hot Rolled Structural Steel Reinforced Concrete & Masonry
Wood Frame ICF Tilt-Up Concrete
COMPATIBLE WITH ALL BEARING SYSTEMS
6
NESTABLE PROFILE REDUCES TRANSPORT & HANDLING COSTS
LIGHTWEIGHT PANELS ARE EASILY STORED AND MANEUVERED ON SITE
PANELS PRE-CUT TO YOUR PROJECT SPECIFICATION
ECONOMICAL TO TRANSPORT AND HANDLE
7
3. Perimeter Trims & Restraint Straps
SYSTEM COMPONENTS INSTALL QUICKLY & EASILY
EVEN IN TIGHT WORK ENVIRONMENTS
1. Fasten & Align End Closures to Supporting Structure
2. Place & Fasten Deck
4. Rib Reinforcement & Wire Mesh Placement
5. Secure Post Shoring
6. Place Concrete
9
MATERIAL AVINGS
70% LESS REBAR VS. CONVENTIONAL 7” SLAB
SIMPLE, ONE-WAY BAR REINFORCEMENT IN EACH TROUGH
10
65% LESS SHORING VS.
CONVENTIONAL CONCRETE SLAB
COMSLAB® is a permanent steel form that eliminates the need for temporary forms
WINNING PERFORMANCE
Long, clear spans (32’) allow for open concept designs
Shallow overall slab depth (10.5”) = low floor-to-floor height
Maximize usable interior height
➢Inverted reinforced ComSlab beam spanning concrete columns
Alternative to Concrete Column & Flat Slab
➢ ComSlab panels running perpendicular to Inverted ComSlab Beams
Alternative to Concrete Column & Flat Slab Cont’d
COMSLAB® & Tested & Listed ULC Design F909 - 1.0-HR Fire Resistant Rating Unprotected with 2.5” Concrete Topping; 1.5-HR Fire Resistant Rating Unprotected with 3.5” Concrete Topping
ULC Design D500 – 2.0-HR Fire Resistant Rating w/5/8” Drywall Membrane & 3.5” Concrete Topping
UL Design D930 – 2.0-HR Fire Resistant Rating Unprotected w/minimum 4.5” Concrete Topping & Modified Rebar Placement
SERVICE & SUPPORT
Fully engineered & tested
Certified load tables
Standard & custom construction details developed
Design assistance
Distribution available across Canada
Over 1000 installed projects completed in a variety of building types
Manufactured in Canada
TO LEARN MORE, OR TO RECEIVE A BUDGET QUOTATION FOR YOUR UPCOMING PROJECT, PLEASE CALL OR EMAIL:
Mark Gordon BUSINESS DEVELOPMENT [email protected] 604-590-5100 604-830-0582 (MOBILE)