2
The Basics Low Surface Area Mesh Handling Color Mesh Mesh Weight (g/m 2 ) Pore Size (mm 2 ) Fiber Diameter (microns) Length of Fiber (cm/cm 2 ) Surface Area Ratio 1 Thickness (microns) Pliability 3 (N) Suture Pull-Out Strength 2 (N) Mesh Color Uphold LITE Vaginal Support System (BSC) 25 2.8 100 35.4 1.11 200 0.53 17.0 Blue w/ Natural Center Stripe Exair Device, NovaSilk Mesh (Coloplast) 24 1.4* 75 58.5 1.40 279 0.15 12.1 Natural Elevate Device, IntePro Lite Mesh (ASTORA) 26 1.8* 75 63.4 1.52 381 0.15 17.3 Natural Comprehensive Mesh Specifications For Transvaginal Mesh Kits LITE Mesh (featured in Uphold LITE Vaginal Support System with Capio SLIM Suture Capturing Device) is more than just a light-weight mesh. It is a balance of: Low Surface Area, Enhanced Handling Characteristics and features Blue Material. Mesh Mesh Weight (g/m 2 ) Pore Size (mm 2 ) Fiber Diameter (microns) Length of Fiber (cm/cm 2 ) Surface Area Ratio 1 Thickness (microns) Pliability 3 (N) Suture Pull-Out Strength 2 (N) Mesh Color LITE Mesh (BSC) 25 2.8 100 35.4 1.11 200 0.53 17.0 Blue w/ Natural Center Stripe Uphold (BSC) 40 1.6 100 47.6 1.63 200 0.59 20.3 Natural w/ Center Stripe Uphold LITE Mesh (BSC) Mesh Mesh Weight (g/m 2 ) Pore Size (mm 2 ) Fiber Diameter (microns) Length Fiber (cm/cm 2 ) Surface Area Ratio 1 Thickness (microns) Pliability 3 (N) Suture Pull-Out Strength 2 (N) Mesh Color LITE Mesh (BSC) 25 2.8 100 35.4 1.11 200 0.53 17.0 Blue w/ Natural Center Stripe NovaSilk (Coloplast) 24 1.4* 75 58.5 1.40 279 0.15 12.1 Natural NovaSilk Mesh (Coloplast) Mesh Mesh Weight (g/m 2 ) Pore Size (mm 2 ) Fiber Diameter (microns) Length of Fiber (cm/cm 2 ) Surface Area Ratio 1 Thickness (microns) Pliability 3 (N) Suture Pull-Out Strength 2 (N) Mesh Color LITE Mesh (BSC) 25 2.8 100 35.4 1.11 200 0.53 17.0 Blue w/ Natural Center Stripe IntePro Lite ASTORA 26 1.8* 75 63.4 1.52 381 0.15 17.3 Natural IntePro Lite Mesh (ASTORA) *These products have a large pore with a single fiber crossing over the pore. These pore values were measured using the cross-fiber as a defining segment of the pore. 1 Surface area ratio and fiber length within 1cm 2 of mesh were calculated from measured mesh weight (g/m 2 ) and measure fiber diameter. 2 Suture pull-out testing per ASTM D882 in transverse direction of knit. 3 Pliability (Stiffness) measured using a modified ASTM D4032 (single layer of mesh 50mm x 90mm). 4 Samples sizes range from 1-5 for non-BSC mesh products vs. 20 or more samples tested for BSC PFR Kits. Averages recorded where multiple samples were measured. All photographs taken by Proxy BioMedical. All Data is the product of bench-testing. Bench Test results may not necessarily be indicative of clinical performance. Data on file.

Comprehensive Mesh Specifications - Boston Scientific · For Uphold LITE: CAUTION: the Federal Law (USA) restricts these devices to sale by or on the order of a physician trained

  • Upload
    lamdat

  • View
    212

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Comprehensive Mesh Specifications - Boston Scientific · For Uphold LITE: CAUTION: the Federal Law (USA) restricts these devices to sale by or on the order of a physician trained

The Basics Low Surface Area Mesh Handling Color

Mesh

Mesh Weight(g/m2)

Pore Size

(mm2)

Fiber Diameter (microns)

Length of Fiber

(cm/cm2)

Surface Area

Ratio1

Thickness (microns)

Pliability3 (N)

Suture Pull-Out

Strength2 (N)MeshColor

Uphold LITE Vaginal Support System (BSC) 25 2.8 100 35.4 1.11 200 0.53 17.0

Blue w/Natural

Center Stripe

Exair™ Device, NovaSilk™ Mesh (Coloplast) 24 1.4* 75 58.5 1.40 279 0.15 12.1 Natural

Elevate™ Device,IntePro™ Lite™ Mesh (ASTORA) 26 1.8* 75 63.4 1.52 381 0.15 17.3 Natural

Comprehensive Mesh SpecificationsFor Transvaginal Mesh Kits

LITE Mesh (featured in Uphold™ LITE Vaginal Support System with Capio™ SLIM Suture Capturing Device) is more than just a light-weight mesh. It is a balance of: Low Surface Area, Enhanced Handling Characteristics and features Blue Material.

Mesh

Mesh Weight(g/m2)

Pore Size

(mm2)

Fiber Diameter (microns)

Length of Fiber

(cm/cm2)

SurfaceAreaRatio1

Thickness (microns)

Pliability3 (N)

Suture Pull-Out Strength2

(N)MeshColor

LITE Mesh(BSC) 25 2.8 100 35.4 1.11 200 0.53 17.0

Blue w/Natural

Center Stripe

Uphold(BSC) 40 1.6 100 47.6 1.63 200 0.59 20.3

Natural w/ Center Stripe

Uphold LITE Mesh (BSC)

Mesh

Mesh Weight(g/m2)

Pore Size

(mm2)

Fiber Diameter (microns)

Length Fiber

(cm/cm2)

SurfaceAreaRatio1

Thickness (microns)

Pliability3 (N)

Suture Pull-Out Strength2

(N)MeshColor

LITE Mesh(BSC) 25 2.8 100 35.4 1.11 200 0.53 17.0

Blue w/Natural

Center Stripe

NovaSilk(Coloplast) 24 1.4* 75 58.5 1.40 279 0.15 12.1 Natural

NovaSilk Mesh (Coloplast)

Mesh

Mesh Weight(g/m2)

Pore Size

(mm2)

Fiber Diameter (microns)

Length of Fiber

(cm/cm2)

SurfaceAreaRatio1

Thickness (microns)

Pliability3 (N)

Suture Pull-Out Strength2

(N)MeshColor

LITE Mesh(BSC) 25 2.8 100 35.4 1.11 200 0.53 17.0

Blue w/Natural

Center Stripe

IntePro LiteASTORA 26 1.8* 75 63.4 1.52 381 0.15 17.3 Natural

IntePro Lite Mesh (ASTORA)

*These products have a large pore with a single fiber crossing over the pore. These pore values were measured using the cross-fiber as a defining segment of the pore.

1 Surface area ratio and fiber length within 1cm2 of mesh were calculated from measured mesh weight (g/m2) and measure fiber diameter. 2 Suture pull-out testing per ASTM D882 in transverse direction of knit. 3 Pliability (Stiffness) measured using a modified ASTM D4032 (single layer of mesh 50mm x 90mm). 4 Samples sizes range from 1-5 for non-BSC mesh products vs. 20 or more samples tested for BSC PFR Kits.

Averages recorded where multiple samples were measured. All photographs taken by Proxy BioMedical.

All Data is the product of bench-testing. Bench Test results may not necessarily be indicative of clinical performance. Data on file.

Page 2: Comprehensive Mesh Specifications - Boston Scientific · For Uphold LITE: CAUTION: the Federal Law (USA) restricts these devices to sale by or on the order of a physician trained

For Uphold LITE: CAUTION: the Federal Law (USA) restricts these devices to sale by or on the order of a physician trained in use of a surgical mesh for transvaginal repair of pelvic organ prolapse.

Refer to package insert provided with this product for complete Indications for Use, Contraindications, Warnings, Precautions, Adverse Events, and Instructions prior to using these products.

CAUTION: The law restricts these devices to sale by or on the order of a physician. Indications, contraindications, warnings, and instructions for use can be found in the product labeling supplied with each device. Information for use only in countries with applicable health authority registrations. Material not intended for use in France.

Products shown are for INFORMATION purposes only and may not be approved or for sale in certain countries.

Please check availability with your local sales representative or customer service.

Accordingly for medical devices: CAUTION: Federal (U.S.) law restricts this device to sale by or on the order of a physician.

Bench test results may not necessarily be indicative of clinical performance. Data on file.

All images are owned by Boston Scientific.

All trademarks are the property of their respective owners.

Ordering Information

Order Number Description

M0068318170 Uphold™ LITE Vaginal Support System with Capio™ SLIM Suture Capturing DeviceIncludes: (1) Capio SLIM Suture Capturing Device and (1) Uphold LITE Mesh Assembly

Boston Scientific Corporation300 Boston Scientific WayMarlborough, MA 01752www.pelvic-floor-institute.com

Ordering Information 1.888.272.1001

© 2016 Boston Scientific Corporation or its affiliates. All rights reserved.