4
Ref: BROCHURE_EXPORT_1016_EN_v.1.0 - Edition: 04/09/2019 CRISTALENS INDUSTRIE 4 rue Louis de Broglie - 22300 Lannion - FRANCE Tel +33 (0)2 96 48 92 92 - Fax +33 (0)2 96 48 97 87 www.cristalens.fr MULTIFOCAL TORIC HYDROPHOBIC INTRAOCULAR LENSES PRELOADED A technology designed for continuous sharp binocular vision from 40 to 90 cm without compromising distance vision Complementary implants with continuous phase PRELOADED IN Two complementary profiles: PLUS MID

Complementary implants with continuous phase · 0.4 0.5 MTF@50c/ mm- pupil 3 mm add (D) - corneal plane-0.5 0.51 1.52 2.5 0.3 Complementary MTFs Propagation of optical rays with ARTIS

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Complementary implants with continuous phase · 0.4 0.5 MTF@50c/ mm- pupil 3 mm add (D) - corneal plane-0.5 0.51 1.52 2.5 0.3 Complementary MTFs Propagation of optical rays with ARTIS

Ref

: BR

OC

HU

RE

_EXP

OR

T_10

16_E

N_v

.1.0

- E

dit

ion

: 04

/09/

2019

CRISTALENS INDUSTRIE4 rue Louis de Broglie - 22300 Lannion - FRANCETel +33 (0)2 96 48 92 92 - Fax +33 (0)2 96 48 97 87

www.cristalens.f r

MULTIFOCAL TORIC HYDROPHOBIC INTRAOCULAR LENSES

PRELOADED

A technology designed for continuous sharp binocular vision from 40 to 90 cm without

compromising distance vision

Complementary implants with continuous phase

PRELOADED

IN

Two complementary profiles:

PLUSMID

Page 2: Complementary implants with continuous phase · 0.4 0.5 MTF@50c/ mm- pupil 3 mm add (D) - corneal plane-0.5 0.51 1.52 2.5 0.3 Complementary MTFs Propagation of optical rays with ARTIS

Continuous phase

Discontinuous phase

SYMBIOSE MID example

Distance visionIntermediate to near vision

SYMBIOSE PLUS example

Trifocal example

INNOVATIVE BINOCULAR TECHNOLOGY➤ Optimized optical profiles, calculated with innovative design and simulation tools developed by Cristalens Industrie for diffractive technology.

MTFs’ complementarity 1 2 3

Theoretical diagram: MTF & PTF @50c/mm – Pupil 3 mm

IOLs WITH PROGRESSIVE COMPLEMENTARITY➤ ARTIS SYMBIOSE MID and PLUS are designed with progressive depth of field complementary in binocular vision to provide «full focus» vision from 40 to 90 cm without compromising distance vision.

IOLs WITH PHASE CONTINUITY ➤ The through-focus continuous phase insures image sharpness throughout depth of field from intermediate to near vision.4

LEGEND:

__ Through-focus MTF = contrast__ Through-focus phase

2 3

SUPERIOR CONTINUUMFOR INTERMEDIATE VISION

ARTISSYMBIOSE

MID

SUPERIOR CONTINUUM FOR NEAR VISION

ARTISSYMBIOSEPLUS

+

Distance of vision Infinity 1 m 80 cm 66 cm 50 cm 40 cm 35 cm

0

0

0.1

0.2

0.4

0.5

MTF

@50

c/m

m- p

up

il 3

mm

add (D) - corneal plane

-0.5 0.5 1 1.5 2 2.5

0.3 Complementary MTFs

Propagation of optical rays with ARTIS SYMBIOSE MID & PLUS diffractive profiles

MID

PLUS

ARTIS SYMBIOSE MIDINTERMEDIATE VISION

ARTIS SYMBIOSE PLUSNEAR VISION

CONTINUOUS SHARP VISIO

N

FROM 40 TO 90 CM

Page 3: Complementary implants with continuous phase · 0.4 0.5 MTF@50c/ mm- pupil 3 mm add (D) - corneal plane-0.5 0.51 1.52 2.5 0.3 Complementary MTFs Propagation of optical rays with ARTIS

1 Castignoles F, New EDOF IOL set, 36th ESCRS congress, Vienna, Austria, September 22-28 2018. 2 Castignoles F, Lamy S, New set of complementary extended-depth-of-focus IOL: comparison with the state-of-the-art, ARVO meeting, Vancouver, Canada, April 28- May 2 2019.3 Philippaki E, Gobin L, Mandoda J, Lamy S, Castignoles F. Optical evaluation of new-design multifocal IOLs with extended depth of focus. J Opt Soc Am A Opt Image Sci Vis. 2019 May 1;36(5):759-767.4 Mandola J, Castignoles F, Philipakki E. Optical evaluation of new-design multifocal IOLs with extended depth of focus, VPO conference, Athens, Greece, August 29-31 2018. 5 K Weston, R Nicholson, C Bunce… An 8-year retrospective study of cataract surgery and postoperative endophthalmitis: injectable intraocular lenses may reduce the incidence of postoperative endophthalmitis. Br J Ophthalmol. 2015 Oct;99(10):1377-80.

Simulation of optotypes from distance to near vision for a 3 mm pupil 2

ARTIS SYMBIOSE®: IMAGE SIMULATION

SHARP & CONTINUOUS BINOCULAR VISION FROM 40 TO 90 CM

COMPARISON WITH EXISTING TECHNOLOGIES➤ Constant contrast➤ Vision continuity at all intermediate to near distances

- UNBALANCED CONTRAST NO NEAR VISION

- DISCONTINUITY BETWEEN NEAR AND INTERMEDIATE VISION

TRIFOCALADD. 1.66 or 1.75D

≅ 80 cm

3.33D ou 3.5D≅ 40 CM

3.25D≅ 40 CM

1.75D ≅ 82 CM

TRIFOCALADD. 2.17 D ≅ 60 cm

EDOF ARTIS SYMBIOSE®

BINOCULAR VISION

FAR

INTE

RN

EA

R80

CM

60 C

M

CONTINUOUS SHARP

VISION

FROM 40 TO 90 CM

4 5

ARTIS SYMBIOSE®

RESULTS

Preloaded system personalized for Cristalens Industrie’s hydrophobic IOLs: 2 mm incision size.

Preloaded IOLs tend to reduce endophthalmitis5 due to the absence of manipulation of the intraocular lens.Remove the lens holder, hydrate for 1 minute, protect your IOL with viscoelastic product, clip the cartridge and everything is ready for injection:

➤ IOL inspection possible before injection,➤ Easy to use,➤ No need for help,➤ IOL stays hydrated,➤ One of your hands is free (unlike a screw loading system).

OPTIMIZED PRELOADED SYSTEM

Distance

5 m

90 cm

80 cm

70 cm

60 cm

50 cm

40 cm

37 cm

EDOF TRIFOCAL SYMBIOSE MID PLUS

Page 4: Complementary implants with continuous phase · 0.4 0.5 MTF@50c/ mm- pupil 3 mm add (D) - corneal plane-0.5 0.51 1.52 2.5 0.3 Complementary MTFs Propagation of optical rays with ARTIS

• TORIC MULTIFOCAL •

TECHNICAL SPECIFICATIONS

Lens type For implantation in the capsular bag

Optic diameter 6.00 mm (from +10.0D to +25.0D)5.80 mm (from +25.5D to +35.0D)

Overall diameter 10.79 mm (from +10.0D to +35.0D)10.50 mm (from +25.5D to +35.0D)

Design One-piece square edge on 360°

Optic design

Diffractive multifocal extended depth of focus, with binocularcomplementarityAspherical with negative spherical aberration to partly correct corneal spherical aberrationDiffractive pattern on the anterior face, biconvex

Angulation 5°

Material Hydrophobic CBK 1.8 from Cristalens

Dioptric powers From +10.0D to +35.0D by 0.5D

Additions (at IOL plane) MID: Superior intermediate vision / PLUS: Superior near vision

Estimated A-Constant (SRK-T) 119.3 Ultrasound biometry119.7 Interference laser biometry

Suggested Anterior ChamberDepth (ACD)

5.77 mm Ultrasound biometry6.03 mm Interference laser biometry

Refractive index 1.54

Sterilization Ethylene oxide

Injection system Preloaded system

Recommended incision size 2.0 mm

Optic design

Diffractive multifocal extended depth of focus, with binocularcomplementarity and variable toricityAspherical with negative spherical aberration to partly correct corneal spherical aberrationDiffractive pattern on the anterior face, toricity and marks onthe posterior face, biconvex

Dioptric powers From +10.0D to +35.0D by 0.5D

Addition (at IOL plane) MID: Superior intermediate vision / PLUS: Superior near vision

Cylinder powers +0.75D / +1.50D (+2.25D / +3.00D / +3.75D on request)

Also available in TORIC version to correct corneal astigmatism for astigmatic patients:

• MULTIFOCAL •

6 7

ARTIS SYMBIOSE® CALCULATOR

Eye selection

Computed toric iol

Post-operative predictions

Pre-operative information

RIGHT EYE (OD)

Diopter (D)

Flat axis:

Steep axis:

Pre-operative astigmatism:

Crossed cylinder (at corneal plane):

Recommended cylindrical power*:

Cristalens toric IOL:

IOL axis of placement:

Estimated residual astigmatism:

* I want to select a different cylindrical power than the one suggested

Include posterior corneal astigmatism

Millimeter (mm)

K1

K2

IOL spherical power (SEQ)

Keratometry data in

D

D

D

x

x

x

@

LEFT EYE (OS)

▶▶

▶▶

▶▶ ▶▶

30.00

0.00 D

0.00 D

90°

90°

30.00 90

Calculation Print New calculation

MID