14
E 2 envitech engineering Company No: IP0178893-T CORPORATE CATALOG AARON ONG, Sales Manager 48, Persiaran Wira Jaya Timur 46, 31350 Ipoh, Perak DR Tel: 05-3138795, Fax: 05-3115542, Mobile: 012-5059161 Web: www.envitech-engrg.com Email: [email protected]

Company No: IP0178893 -T CORPORATE CATALOG · PDF fileCompany No: IP0178893 -T CORPORATE CATALOG ... Among such legislation is the Occupational Safety & Health Act 1994 USECHH

  • Upload
    phamdat

  • View
    214

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Company No: IP0178893 -T CORPORATE CATALOG · PDF fileCompany No: IP0178893 -T CORPORATE CATALOG ... Among such legislation is the Occupational Safety & Health Act 1994 USECHH

E2 envitech engineering Company No: IP0178893-T

CORPORATE CATALOG

AARON ONG, Sales Manager

48, Persiaran Wira Jaya Timur 46, 31350 Ipoh, Perak DR Tel: 05-3138795, Fax: 05-3115542, Mobile: 012-5059161

Web: www.envitech-engrg.com Email: [email protected]

Page 2: Company No: IP0178893 -T CORPORATE CATALOG · PDF fileCompany No: IP0178893 -T CORPORATE CATALOG ... Among such legislation is the Occupational Safety & Health Act 1994 USECHH

E2 envitech engineering Company No: IP0178893-T 48, Persiaran Wira Jaya Timur 46, 31350 Ipoh, Perak DR Tel: 05-3138795, Fax: 05-3115542, Mobile: 012-5059161 Web: www.envitech-engrg.com

COMPANY PROFILE

CORPORATE POLICY

The dynamism of ENVITECH ENGINEERING is reflected in our four -step mission:

• To become a one stop advisor, supplier, contractor and partner to our customers.

• To provide unmatched customer service by providing personal attention & professional

service.

• To provide quality products and services at affordable prices.

• To promote care for the environment of the Earth we live in.

ENVITECH ENGINEERING (Established 2002) is a contraction of two words “ENVIronmental TECHnology”. The E2 (E Squared) logo hints at a background of mathematics and creative engineering, the basis of our expertise. ENVITECH ENGINEERING is primarily focused on providing engineering products and services to a wide variety of industries offering turnkey solutions ranging from advisory services, detailed design/drawings to installation and maintenance. We form a vital backbone for national growth through our specialization in engineering processes and services. Drawing upon our wealth of engineering expertise & experience, we provide the following products and services: • Air Pollution Control Systems & Advisory Services • Ventilation, Exhaust Fans and Systems • Hygiene Technician Services • Piping and Pumping Systems • FRP Tanks, Vessels, Customised Works & Furniture • Steel Tanks, Frames, Structural Works etc. • Laboratory Construction & Cleanroom Systems • Industrial Coating, Flooring & Liner Systems • Safety Products, Equipment & PPEs • General Commercial & Industrial Works ENVITECH ENGINEERING offers superior products coupled with prompt and efficient service and creates solutions tailored specifically for each customer’s unique needs, large or small. Our products and services are suitable for: • Power Generation, Water Treatment and Utility Plants • Hospitals, Pharmaceuticals and Laboratories • Chemical Manufacturing Plants & other factories • SMR, Latex and Rubber Glove Factories • Commercial Buildings and High Rises • Schools, Colleges and Higher Education Institutions • Naval and Military Installations All inquiries, no matter how big or small, complex or simple, are welcome.

Page 3: Company No: IP0178893 -T CORPORATE CATALOG · PDF fileCompany No: IP0178893 -T CORPORATE CATALOG ... Among such legislation is the Occupational Safety & Health Act 1994 USECHH

E2 envitech engineering Company No: IP0178893-T 48, Persiaran Wira Jaya Timur 46, 31350 Ipoh, Perak DR Tel: 05-3138795, Fax: 05-3115542, Mobile: 012-5059161 Web: www.envitech-engrg.com

MS Skid Tank

FRP Chemical Tanks

FRP Slurry Tank

Pressed Steel Panel Tank SS Pharmaceutical Tank FRP Panel Tank for Hospital On High Tower

SS Cadaver Storage Tank for Medical College

Page 4: Company No: IP0178893 -T CORPORATE CATALOG · PDF fileCompany No: IP0178893 -T CORPORATE CATALOG ... Among such legislation is the Occupational Safety & Health Act 1994 USECHH

E2 envitech engineering Company No: IP0178893-T 48, Persiaran Wira Jaya Timur 46, 31350 Ipoh, Perak DR Tel: 05-3138795, Fax: 05-3115542, Mobile: 012-5059161 Web: www.envitech-engrg.com

ENVITECH Quikscrub Acid Fume Scrubber Systems Features: • High Efficiency • Low Maintenance • Fully Automatic • Full Range of Options • Corrosion Resistant FRP or Stainless Steel Application: • Chemical Plants • Water Treatment Plants • Rubber Mills • Rubber Glove Manufacturing • Electroplating

Above – 36,000 cfm Quikscrub Odour Scrubber with Service Tower for Rubber Mill Left - 6,000 cfm Quikscrub Emergency Chlorine Scrubber System for Water Treatment Plant Right – 1,000 cfm ENVITECH Ecoscrub Air Washer System for Malay-Sino Chemical Industries Sdn. Bhd., Ipoh.

ENVITECH Ecoscrub Low Cost Air Washer System for • Fume Cupboards • Laboratories • Other Low End Applications Features: • Low Cost • Low Maintenance • Simple Design • Quick Delivery & Installation

envitech engineering Always At the Forefront of Environmental Protection.

Page 5: Company No: IP0178893 -T CORPORATE CATALOG · PDF fileCompany No: IP0178893 -T CORPORATE CATALOG ... Among such legislation is the Occupational Safety & Health Act 1994 USECHH

E2 envitech engineering Company No: IP0178893-T 48, Persiaran Wira Jaya Timur 46, 31350 Ipoh, Perak DR Tel: 05-3138795, Fax: 05-3115542, Mobile: 012-5059161 Web: www.envitech-engrg.com

Always At the Forefront

Fully Automatic Dust Collection Systems for: • Wood & Timber • Furniture • Metal Casting • Cement • Calcium Carbonate • Kaolin • Ceramic • Pigment • Food • Rubber Glove industries • Water Treatment industries. All Systems come complete with Bag/Envelope Filters, Jet Pulsing mechanism, timer card, exhaust fan, exhaust ducting, rotary valve and others.

(Above) Envitech 1,200 cfm system for water treatment plant METROPOLITAN UTILITY CORPORATION SDN. BHD. Year: April 1996 Project Price: RM 63,800 (Left) Envitech 2,000 cfm High Pressure system for Ferrous Dust

ACME FERRITE PRODUCTS SDN. BHD., IPOH. Year: December 2003 Project Price: RM 76,800

envitech engineering Always At the Forefront of Environmental Protection.

Page 6: Company No: IP0178893 -T CORPORATE CATALOG · PDF fileCompany No: IP0178893 -T CORPORATE CATALOG ... Among such legislation is the Occupational Safety & Health Act 1994 USECHH

E2 envitech engineering Company No: IP0178893-T 48, Persiaran Wira Jaya Timur 46, 31350 Ipoh, Perak DR Tel: 05-3138795, Fax: 05-3115542, Mobile: 012-5059161 Web: www.envitech-engrg.com

We Supply & Service: Ducted Axial Fans Centrifugal Fans Wall Propeller Fans

Design, Installation Testing & Commissioning of Various Types of Exhaust Hoods, Ducting & Local Exhaust Ventilation

Both Pictures Above: PP Slotted Booth Hoods for Water Treatment Plants Left: Taper Hood for Laboratory AA Spectrometer Right: Canopy Hoods for oven exhaust

Page 7: Company No: IP0178893 -T CORPORATE CATALOG · PDF fileCompany No: IP0178893 -T CORPORATE CATALOG ... Among such legislation is the Occupational Safety & Health Act 1994 USECHH

E2 envitech engineering Company No: IP0178893-T 48, Persiaran Wira Jaya Timur 46, 31350 Ipoh, Perak DR Tel: 05-3138795, Fax: 05-3115542, Mobile: 012-5059161 Web: www.envitech-engrg.com

Air Pollution Control Seminar for Jabatan Alam Sekitar, Chimney Design & Submission to Jabatan Computerised Fan Balancing Kota Bharu, Kelantan and UKM. 29 April 2002 Alam Sekitar For Approval

Air Monitoring Service for Lee Rubber Co. Pte Ltd (Above) Ammonia Gas Monitoring for Lee Latex Penang Oct 2004 Pte Ltd. Taiping, Perak. Aug 2004

(Right) Air Monitoring For Acme Ferrite Products Sdn. Bhd. Ipoh. Nov 2003 (Left) Air Capacity Measurement For Imerys Honaik Sdn. Bhd. Feb 2005

(Right) Air Capacity Measurement for Kota

Trading SB, N. Sembilan. May 2005

(Left) Fume Cupboard testing for YTL Cement Bhd. Padang Rengas Nov 2008

(Right ) Reports, Drawings and Documentation

ALL INQUIRIES WELCOME!

We provide Registered Hygiene Technician II Services (DOSH Reg: JKKP HIE 127/171-3/2 (136))

Page 8: Company No: IP0178893 -T CORPORATE CATALOG · PDF fileCompany No: IP0178893 -T CORPORATE CATALOG ... Among such legislation is the Occupational Safety & Health Act 1994 USECHH

E2 envitech engineering Company No: IP0178893-T 48, Persiaran Wira Jaya Timur 46, 31350 Ipoh, Perak DR Tel: 05-3138795, Fax: 05-3115542, Mobile: 012-5059161 Web: www.envitech-engrg.com

INSPECTION & TESTING WHAT IS INSPECTION & TESTING OF LEV SYSTEMS ? Inspection & Testing is the step by step procedural inspection and testing of LEV (Local Exhaust Ventilation) systems in order to check its operating characteristics, parameters and specifications. Typical characteristics & parameters include face or slot velocity, duct velocity, chimney velocity, static pressure, fan speed, motor bhp etc. Instruments used include, where applicable, pitot probe, digital tachometer, smoke tubes, thermocouple, digital velocimeter etc.

WHY PERFORM INSPECTION & TESTING?

1. To compare against supplier or manufacturers’ specifications 2. To comply with legislation or Government directives. 3. To comply with approved Standards 4. To check physical health of system and reveal performance 5. As a basis for maintenance and future modification of system

1. Comparison with suppliers’/manufacturers’ specifications How does one check a system e.g., an exhaust fan, installed by a supplier complies with its own specifications? For instance, if the supplier indicates that the system is designed for operation at a capacity of 10,000 CFM (cubic feet per minute), does the system actually operate at that capacity? And if not, how much is the variance or difference? The results obtained from an Inspection & Testing can form the basis of acceptance or rejection of the system by the customer. 2. Compliance with legislation or Government directives All owners/operators of LEV systems installed in the country are required to observe the relevant Act and Regulations concerning the operation of such systems. Among such legislation is the Occupational Safety & Health Act 1994 USECHH 2000 Regulations which require the “engineering control equipment” to be “… examined and tested for its effectiveness by a hygiene technician…” every twelve months interval. Regulation 40 of the Clean Air Regulations 1978 Environmental Quality Act 1974 requires any “control equipment” in use to be “in proper operation” at all times. Both regulations are enforced by the Department of Safety & Health and the Department of Environment respectively. The Department of Environment also publishes a Technical Guideline entitled, “Technical Guidelines Series Number DOE-2-2004 - Perform ance Monitoring of Air Pollution Control System”. 3. Compliance with approved Standards LEV systems are required to be designed according to approved standards in order to guarantee optimum performance. If a system is not designed accordingly, the system will fail to do the job that it was meant for. An Inspection & Testing will reveal whether a system complies or not with approved standards The American Conference of Governmental Industrial Hygienists (ACGIH) and the American Society of Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE) both publish technical design and engineering standards in their internationally accepted handbooks.

4. Physical Health of System and Revelation of Performance Inspection & Testing allows LEV systems to be evaluated on their “health” status via the measurement and/or observation of its vital parameters such as static pressure, velocity, capacity, condition, vibration, temperature etc. Abnormal pressure readings, for instance, may indicate blockage along the system and further measurements can usually determine the location and cause of the problem. Observation on air movement devices, for example, may reveal reversed impeller direction, or severe vibration indicating the need for impeller balancing services, a very common occurrence.

5. Basis for Design, Maintenance/Repair and Future Modification of system LEV systems need to be periodically maintained, sometimes repaired, in order to maintain their original designed performance. Inspection & Testing determines the correct form of maintenance and type of spares necessary. Also, at some point during their lifespan, LEV systems may need to be modified to cater for revised performance parameters such as an increase or decrease in capacity or pressure. Air Monitoring carried out and its subsequent calculations can reveal the quantum of changes necessary to effect the modification. Whether it is just a calculation for a different pulley size for the air movement device or perhaps a new size for the exhaust duct, the possibilities are endless. January 2005

Checking efflux velocity of chimney

A digital velocimeter

Checking motor speed

Page 9: Company No: IP0178893 -T CORPORATE CATALOG · PDF fileCompany No: IP0178893 -T CORPORATE CATALOG ... Among such legislation is the Occupational Safety & Health Act 1994 USECHH

E2 envitech engineering Company No: IP0178893-T 48, Persiaran Wira Jaya Timur 46, 31350 Ipoh, Perak DR Tel: 05-3138795, Fax: 05-3115542, Mobile: 012-5059161 Web: www.envitech-engrg.com

SS304 tank c/w Exhaust Hood SS304 Hospital Scrub Sink SS304 Nested Tanks

SS304 Cadaver Storage Tank for Medical College

SS304 Wash Basin with Dissection Table SS304 Cadaver Dissection Trolley SS304 Bowl for Hospital Operation Theatre SS304 Pail for Bodily Fluids SS304 Scrub Sink

SS304 Cabinet with Tempered Glass Doors

SS 304 Sinks with swan neck taps and Emergency Eyewash SS 304/316 Process Chemical Tanks We design and fabricate to custom requirements all types and sizes of Stainless Steel Process/Pressure/Jacketed Tanks & Miscellaneous items in the following areas:

1. Hospital/Medical 2. Pharmaceutical 3. Food Processing 4. Chemical 5. Rubber Glove 6. Military

Page 10: Company No: IP0178893 -T CORPORATE CATALOG · PDF fileCompany No: IP0178893 -T CORPORATE CATALOG ... Among such legislation is the Occupational Safety & Health Act 1994 USECHH

E2 envitech engineering Company No: IP0178893-T 48, Persiaran Wira Jaya Timur 46, 31350 Ipoh, Perak DR Tel: 05-3138795, Fax: 05-3115542, Mobile: 012-5059161 Web: www.envitech-engrg.com

We Design, Fabricate, Install, Sell, Service & Maintain All Kinds of Laboratory Fitting & Furniture for Schools, Colleges & Industries

CHEMICAL RESISTANT LABORATORY FURNITURE, CONSTRUCTION & RENOVATION

CALL 0 1 2 - 5 0 5 9 1 6 1 FOR MORE INFORMATION

PP/Epoxy Sink Lab. Water Taps Lab. Gas Taps Stainless Steel Cart

Perchloric Acid Hood/ Fume Cupboard

Emergency Shower & Eyewash

Flammable Storage Cabinet

FRP Exhaust Fan With FRP Chimney

Wall Bench with Ecolab Fume Cupboard Epoxy Floor

Wall Bench

Hexagonal Island

Seamless Epoxy Flooring Wall Bench with Reagent Rack

Neutralizing Tank

Page 11: Company No: IP0178893 -T CORPORATE CATALOG · PDF fileCompany No: IP0178893 -T CORPORATE CATALOG ... Among such legislation is the Occupational Safety & Health Act 1994 USECHH

E2 envitech engineering Company No: IP0178893-T 48, Persiaran Wira Jaya Timur 46, 31350 Ipoh, Perak DR Tel: 05-3138795, Fax: 05-3115542, Mobile: 012-5059161 Web: www.envitech-engrg.com

We undertake Design and Construction of Cleanrooms from FS209E Class 1 to Class 100K Standards or equal. We also supply: • Air showers • Pass-thru boxes • Cleanbench • Filters • Tacky Mats • Various Stain less Steel furniture

(Above) FS209E Class 100000 Cleanroom with: • Epoxy SL Floor • Class 100 Cleanbench • Epoxy Coated Partitions

(Above) Testing and Commissioning of Cleanroom using MetOne 4-Channel Particle Counter.

(Above) ISO 14644 Class 8 Material Buffer Room (Left) Particle count in progress

Right) ISO 14644 Class 7 Sampling Room for Non Sterile Raw Material (Left) SS Washing Sink with Emergency Eyewash

Page 12: Company No: IP0178893 -T CORPORATE CATALOG · PDF fileCompany No: IP0178893 -T CORPORATE CATALOG ... Among such legislation is the Occupational Safety & Health Act 1994 USECHH

E2 envitech engineering Company No: IP0178893-T 48, Persiaran Wira Jaya Timur 46, 31350 Ipoh, Perak DR Tel: 05-3138795, Fax: 05-3115542, Mobile: 012-5059161 Web: www.envitech-engrg.com

Gas Metering System for Chlorine

Self Priming Pump Inline Centrifugal Booster Pump

Magnetic Sealless Recirculation Pump Cast Iron Centrifugal Pump

Left: Hands free Sensor Tap Right: Elbow action Medical Tap

Page 13: Company No: IP0178893 -T CORPORATE CATALOG · PDF fileCompany No: IP0178893 -T CORPORATE CATALOG ... Among such legislation is the Occupational Safety & Health Act 1994 USECHH

E2 envitech engineering Company No: IP0178893-T 48, Persiaran Wira Jaya Timur 46, 31350 Ipoh, Perak DR Tel: 05-3138795, Fax: 05-3115542, Mobile: 012-5059161 Web: www.envitech-engrg.com

We supply, lay and install Epoxy Flooring of various thickness grades and

finishes for industries and commercial buildings.

Preparation of Chemicals Mixing Process

Smoothing and Levelling Pouring

Trowelling Spike Rolling Finished Floor

Page 14: Company No: IP0178893 -T CORPORATE CATALOG · PDF fileCompany No: IP0178893 -T CORPORATE CATALOG ... Among such legislation is the Occupational Safety & Health Act 1994 USECHH

E2 envitech engineering Company No: IP0178893-T 48, Persiaran Wira Jaya Timur 46, 31350 Ipoh, Perak DR Tel: 05-3138795, Fax: 05-3115542, Mobile: 012-5059161 Web: www.envitech-engrg.com

WHY COMPROMISE ON SAFETY? We supply, deliver, install and maintain a wide range of Personal Protective Equipment, Professional Fall Arrest Equipment and Safety Devices such as: Other PPEs available: SCBA, Face masks, Gas Detectors, Stretchers, Visors, Safety Signage, Fireman’s helmet, NBC suit, Escape Apparatus etc.

Safety Lanya rd

I T A L Y

3 point full body harness

2 point full body harness

Work position belt & seat harness

Work positioning belt

Safety Tripod

Professional Safety helmets

Professional ultrabright headlamps

2.5 & 10m Retractable

Fall Arresters

Emergency Showers & Eyewash

Flammable Safety Cabinet

Chemical Safety Mobile Cart

Product Safety Training Before Delivery

Fall Arrestor System for Loading Bays