Company Background
• Founded in Cleveland, Ohio (1947)
• 17 facilities worldwide (4 US/13 Overseas)
• US: (Arkansas, North Carolina, New Mexico, Ohio)
• Americas: (Canada, Mexico, Brazil)
• EMEA: (UK, Poland, Spain, South Africa)
• Asia-Pac: (Australia, Thailand, China, Indonesia, Malaysia, New Zealand)
• 2500+ employees worldwide
• Publically traded on NASDAQ (PLPC)
• Acquired Direct Power and Water corp. in 2007
Ballasted Roof Mounts
Power Xpress™
BPRM – Ballasted PowerRail™ Mount
Pole Mounted Racks
TPM – Top of Pole Mount
MPM-G2 – Multi Pole Mount, 2nd Generation
Power Xpress
Roof Mounts
Power Rail™
PRODUCT DISCUSSION
5° and 10° options
Fully ballasted
No penetrations
Full containment ballast trays
Integrated grounding
Pre-assembled clamps
Minimal parts
3/8” EPDM roof protection
Ballast reports
Power Xpress™
Power Fab CRS-G2
RAD Hardware Compatible
Integrated Grounding
New Tilt bracket
Integrated Ballast Pan
Achieve low distributed loads
Installs in High Wind Zones
Spec Inter-row shading
spacing
3/8” EPDM Protective Gasket
EPDM to protect roof
RAD Hardware Compatible
Ballast Pans act as spacers
Single Tool assembly
Capable of installs up to 150mph
Zero degree tilt
BRPM Features/ Selling Points
Great for homes with limited roof space due to shading, orientation, or slope
On-line Configurator tool available
Manufacturer Recommended Foundations
Module Specific Design
Six seasonal elevation set points (15-65 degrees)
Single Pole Ground Penetration
High Wind Version rated up 130mph
Mounts up to 15 60-cell modules per pole
Upgrades and Options Available
Powder Coating
Galvanized Steel and/or anodized aluminum
TPM Technical Discussion
Uses Heavy Duty P14 Module rails
Seasonal Adjustability
RAD Hardware Compatible
Square Horizontal Tubing
Integrated Wire Management
Capable of High Ground Clearance
Multiple Foundation options
POWER-FAB MPM-G2 Multi-Pole Mount G2 Racking System
Fewer Parts to install = Lower
Installed Costs
Form meets Function
Wire Management Lends to a
Professional Looking installation
Helical, Concrete, Pile Driven Pier
Compatibility
Residential, Commercial and
Agricultural applications
POWER-FAB MPM-G2 Multi-Pole Mount G2 Racking System
• Embedded Concrete
• Concrete Blocks/Footers
• Pile Driven Systems in Compacted Soil
• Earth Screws
Augured Hole
Embedded Concrete
Concrete Blocks
Driven Pole Earth Screw
MPM-G2 Foundations
MPM - Load Sharing – Why is it beneficial?
Reduced Foundation Size
Load is spread over multiple pipes/piers
More Pipes/Piers = Less Load Per Pipe/Pier
Foundation Size is also Related to Site and Install Criteria
Cheaper Pipe/Labor:
Smaller Pipe Sizes Used
Pipe Usually Sold by Weight
Smaller Pipe More Available than Larger Pipe
Smaller Pipe/Piers = Less Labor
Increased Ground Clearance
Load Sharing allows for Taller Installs
Can used as a Shade Structure
MPM-G2 - Technical Discussion
How Do the Different Design Criteria Relate? Ground Snow Load vs. Ground Clearance vs. Max Tilt Angle
Ground Clearance
Affects Overall Height of System
Taller Systems require Stronger Pipe and Bigger Foundations
Can be used to Elevate rack above Snow Accumulation
Max Tilt Angle
Steeper Tilts Increase Snow Slough Value
Must Have Ground Clearance Above Snow Levels
Steeper Tilts are Affected by the Elements More Severely
MPM-G2 - Technical Discussion
Relationships Between Criteria
MPM4 is Unavailable in Excessive Conditions
High Snow Loads and Low Ground Clearances
High Wind Speeds and Snow Loads
Low Tilt Angles and High Snow Loads
Pier Frequency
More Piers in Excessive Conditions
Excessive Wind/Snow Require More to Support Rack
High Wind Speeds = More Pressure
Square Footage of Array Requires More Support
MPM-G2 - Technical Discussion
Power Peak™ Structure
Pile Driven Vertical Posts Strong Back Assy.
Module Rails Vertical Attachment
Strut Attachment
Power Peak
Power Peak™
Material Specs
Structural Aluminum Alloys
– Extruded – 6000 Series
– Fabricated – 5052 H-32
Stainless Steel Alloys – Type 304
Galvanized Steel ASTM-A123
Plastics
** Racking Materials selected for superior corrosion
resistance and strength to last the life of the module
Power Peak™ Component Features
1) Strong Back Assembly
Factory Preassembled with preset
module rail mounts
2” Vertical adjustment
Field adjustable strut
2) Module Rails One piece, lightweight aluminum Portrait or Landscape module mounting Built-in cable tray for wire management
3) Module Clamp Assembly Fast ¼ turn twist-in field assembly Integrated grounding
Strong-Back
Assembly
Module Rail
Clamp Assembly
Module Rail
Power Peak
Type 1
Crystalline Bedrock
Type 2
Sedimentary and Foliated Rock
Type 3
Sandy Gravel and/or Gravel
Type 4
Sand, Silty or Clayey Sand, Silty Gravel and Clayey Gravel
Type 5
Clay, Sandy Clay, Silty Clay, Clayey Silt, Silt and Sandy Silt
Soil Types
Power Peak™
Site Specific Design
Save Money in the field
– Field Adjustability
– Pre-Assembly
Material Specification
Finish Specification
– G90 vs ASTM 123A
In Stock right here in Minneapolis to hold 12-40 modules
PowerRail Features/ Selling Points
Many different attachment options
RAD Hardware Compatible
Various Types of L-Feet
Wire Management
Reduced Install Time/ Reduced Labor
Wire Management
RAD Hardware
Reduced Cost
P6 vs P8
Design Friendly
Can attach to all types of structures
Industry Leading Customer Support
• Product Support Specialists
• Specification Tools
• Product Configuration Tools
• Selection and Pricing Guides
• Design Guidelines
• Request for Quote Forms
• Engineering Support
• CAD drawings
• Structural Calculations – wind, seismic, dead loads
• Full Scale Wind Tunnel reports for ballasted systems
• Foundation Recommendations - CAD drawings
• 3rd Party PE certification
• Assembly Instructions & Installation Guidelines