2
APVVSG1401A Preview Compact & Lightweight Design for 4 HP & 5 HP The new design of VRV IV S system has been optimised, with the height for 4 HP & 5 HP reduced to only 990mm. This design gives the building a sleek look from the outside view and the clear view of the scenery without any blockage from the inside of the building. The VRV IV S system is now slim and compact. The highly space saving outdoor units are able to maximise utilisation of installation space. It is an ideal air conditioning system for residential, small offices and shops. Specification* Model name RXMQ4AVE RXMQ5AVE RXMQ6AVE RXMQ8AVE RXMQ9AVE HP 4 HP 5 HP 6 HP 8 HP 9 HP M/C M/C M/C New New 220 ~ 230V Single phase 50Hz * Tentative figures Power Supply Outlook Dimension H x W x D (mm) 990 x 940 x 320 990 x 940 x 320 1,345 x 900 x 320 1,430 x 940 x 320 1,430 x 940 x 320 Weight Kg 78 85 125 150 150 Sound dB(A) 52 53 55 57 58 Cooling Capacity (KW) 11.2 14 16 22.4 24 COP (O-Unit) 3.80 3.54 3.67 3.58 3.32 *The specifications, designs and information in this brochure are subject to change without notice Preliminary Note: Specifications are based on the following conditions; • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions. DAIKIN AIRCONDITIONING (SINGAPORE) PTE LTD 10 Ang Mo Kio Industrial Park 2 Singapore 56950 Tel: 6583 8888 (Main Line) Tel: 6311 8686 (Service Call Centre) www.daikin.com.sg Inside view of a condominium unit Height reduce to 990mm VRV IV S 4 HP, 5 HP VRV III-S 4 HP, 5 HP Outside view of a condominium 380 ~ 415V Three phase 50Hz Refrigerant Type R-410A

Compact & Lightweight Design Specification* Height …suwantawe.com/assets/daikin-VRV-IV-S.pdf · The new design of VRV IV S system has been ... 6583 8888 (Main Line) Tel: 6311 8686

  • Upload
    lamminh

  • View
    225

  • Download
    4

Embed Size (px)

Citation preview

Page 1: Compact & Lightweight Design Specification* Height …suwantawe.com/assets/daikin-VRV-IV-S.pdf · The new design of VRV IV S system has been ... 6583 8888 (Main Line) Tel: 6311 8686

APVVSG1401A Preview

Compact & Lightweight Design for 4 HP & 5 HPThe new design of VRV IV S system has been

optimised, with the height for 4 HP & 5 HP

reduced to only 990mm. This design gives

the building a sleek look from the outside view

and the clear view of the scenery without any

blockage from the inside of the building. The

VRV IV S system is now slim and compact. The

highly space saving outdoor units are able to

maximise utilisation of installation space. It is

an ideal air conditioning system for residential,

small offices and shops.

Specification*

Model name RXMQ4AVE RXMQ5AVE RXMQ6AVE RXMQ8AVE RXMQ9AVE

HP 4 HP 5 HP 6 HP 8 HP 9 HP

M/C M/C M/C New New

220 ~ 230V Single phase 50Hz

* Tentative figures

Power Supply

Outlook

Dimension H x W x D (mm) 990 x 940 x 320 990 x 940 x 320 1,345 x 900 x 320 1,430 x 940 x 320 1,430 x 940 x 320

Weight Kg 78 85 125 150 150

Sound dB(A) 52 53 55 57 58

Cooling Capacity (KW) 11.2 14 16 22.4 24

COP (O-Unit) 3.80 3.54 3.67 3.58 3.32

*The specifications, designs and information in this brochure are subject to change without notice Preliminary

Note: Specifications are based on the following conditions;

• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

DAIKIN AIRCONDITIONING (SINGAPORE) PTE LTD10 Ang Mo Kio Industrial Park 2 Singapore 56950Tel: 6583 8888 (Main Line) Tel: 6311 8686 (Service Call Centre) www.daikin.com.sg

Inside view of a condominium unit

Height reduce to 990mm

Height reduce to 990mm

VRV IV S4 HP, 5 HP

VRV III-S4 HP, 5 HP

Inside view of a condominium unit

Outside view of a condominium

380 ~ 415VThree phase 50Hz

Refrigerant Type R-410A

Page 2: Compact & Lightweight Design Specification* Height …suwantawe.com/assets/daikin-VRV-IV-S.pdf · The new design of VRV IV S system has been ... 6583 8888 (Main Line) Tel: 6311 8686

Enhanced LineupTo suit the variety of room sizes, VRV IV S introduces the new capacity range; 8 HP and 9 HP.

VRV Indoor Units

Enhanced range of indoor unit choices

The VRV IV S system is highly space saving. It offers slim and compact outdoor units to achieve maximum utilization of the installation space. It is an ideal air conditioning system for residential, small offices and shops.

*M/C represents Model Change

Nighttime quiet operation function

Automatic modeMode 1.

Set on the outdoor PCB. Time of maximum temperature is memorised. The low operating mode will become active 8 hours*1 after the peak temperature in the daytime, and operation will return to normal 10 hours*2 after that. The operation sound level for the night mode can be selected from 47 dB(A) (Step 1), 44 dB(A) (Step 2) and 41 dB(A) (Step 3).

Starting time and ending time can be input. (An external control adaptor for outdoor unit, DTA104A61 or DTA104A62, and a locally obtained timer is necessary.)

Manual modeMode 2.

Combinations of modes 1 and 2 can be used depending on your needs.

Combined modeMode 3.

*1. Initial setting. Can be selected from 6, 8 and 10 hours.*2. Initial setting. Can be selected from 8, 9 and 10 hours.

Operation sound level selectablefrom 3 steps for the night mode

Automatic modeMode 1.

Note: • This function is available in setting at site.• The relationship of outdoor temperature (load) and time shown in the graph is just an example.

Peak in outdoor temperature

Capa

city

%

8 hrs 10 hrs

Oper

atio

n so

und

dB(A

)

47

8:00 12:00 16:00 20:00 0:00 4:00 8:00

50

100

500

Load

%

Night mode endsNight mode starts Night mode endsNight mode starts

Night Mode

44

41

(Initial setting)(Initial setting)

Step 1: 47 dB(A)

Step 2: 44 dB(A)

Step 3: 41 dB(A)

The capacity reduction rate differs depending on the operation sound level step selected.

Energy SavingVRV IV S provides greater energy

saving as compared to VRV III-S,

especially for 6 HP.

Higher Coefficient of Performance (COP)

3.2

4HP 5HP 6HP 8HP 9HP

3.4

3.63.53

3.79 3.80

3.543.58

3.32

3.8

4

Incr

ease

5%

Note: BP units are necessary for residential indoor units.

Type Model Name

Residential indoor units with connection to BP units25 35

25 35

2.5 kW 3.5 kW

50 60 71

50 60 71

5.0 kW 6.0 kW 7.1 kWRated Capacity

Capacity Index

(700 mm width type)

(900/1,100 mm width type)

FCQ-BVE

FFQ-BV1B

FBQ-BV1

FDKS-EAVMB

FDKS-C(A)VMB

FTKS-DVM

FTKS-BVMA

FTKS-FVM

Ceiling Mounted Cassette

Ceiling MountedBuilt-in

Slim CeilingMounted Duct

Wall Mounted

Ceiling MountedCassette (Compact Multi Flow)

8 types 22 models

VRV indoor units only

14Max.

indoorunits VRV indoor units

BP unit

Residential indoor units

14Max.

indoorunits

3.49

3.67

Type Model Name Capacity Range

Capacity Index

Floor StandingDuct FXVQ-MY1

ConcealedFloor Standing FXNQ-MAVE

Floor Standing FXLQ-MAVE

FXMQ-MAVE

FXKQ-MAVE

FXCQ-MVE

FXUQ-AVEB

FXZQ-MVE

FXFQ-LUV1

FXFQ-SVM

FXMQ-PVE

Wall Mounted FXAQ-PVE

Ceiling Suspended

Ceiling MountedDuct

Ceiling MountedCassette Corner

4-Way FlowCeiling Suspended

Ceiling MountedCassette (Double Flow)

Ceiling MountedCassette (Compact Multi Flow)

Ceiling MountedCassette (Round Flow)

Ceiling MountedCassette (Round Flow with Sensing)

Slim Ceiling Mounted Duct

FXHQ-MAVE

(900/1,100 mm width type)

(700 mm width type)

FXDQ-NBVET(without drain pump)

FXDQ-PBVET(without drain pump)

FXDQ-PBVE(with drain pump)

FXDQ-NBVE(with drain pump)

20

0.8 HP 1.25 HP 1.6 HP1 HP 2 HP 2.5 HP 3 HP 4 HP 5 HP 6 HP3.2 HP

25 40 50 62.5 71 80 100 125 14031.25

20 25 40 50 63 71 80 100 125 140

8 HP

200

20032

Max.

Max.

VRV III-S

4 HP 8 HP

M/C*

6 HP

M/C*

5 HP

M/C*

M/C*

6 HP6 HP 8 HP

M/C*

5 HP4 HP4 HP

M/C*

NEW

9 HP9 HP

NEW