201 W. Colfax Ave., Dept. 205
Denver, CO 80202
720.865.2709 or [email protected]
Design Review General Appl ication Checkli stDesign review is a collaborative process used to examine projects in designated historic areas or properties for architectural design and compatibility with
-scribes or studies the proposal. To comply with the required submittal standards of Denver Landmark Preservation, submitted documentation shall clearly illustrate the existing conditions as well as any proposed alteration(s).
Submit this form, completed, with the required submittal documentation
Project Address:
The following is REQUIRED:1. Complete Application for Design Review
2. Plans / drawings / sketches that adequately depict the project
3. Details and materials of the project
4. Color photos of existing conditions
Please note: If the proposal includes demolition of an existing structure a separate demolition application will need to be approved.
Review is based on a comparison of the proposal and the Secretary of the Interior’s Standards, Design Guidelines for Landmark Structures and Districts, Landmark Preservation Ordinance; Chapter 30 Revised Municipal Codebuilding or zoning review. Please submit plans to those agencies for comment.
Community Planning & Development
General Application Checklist
LEGAL DISCLAIMER: This Advisory should not be used as a substitute for codes and regulations. The applicant is responsible for compliance with all code, guideline and/or rule requirements, whether or not described in this Advisory.
Landmark Preservation
/ /1
1730 Blake Street
✔
✔
✔
✔
LANDMARK CERTIFICATE OF APPROPRIATENESS – Application
Design review for this project will not begin until a complete application and required submittal materials are received. Landmark Preservation reserves the right to delay consideration and/or action on a submittal in the event that information is missing and/or changed at the time of the scheduled de-sign review or public hearing. Please use the appropriate project checklist for guidance. A pre-application review is required first for certain projects.
SUBJECT PROPERTY INFORMATION
Property Address
Property Type/Use 1 or 2 Unit Building (Single Family Home, Duplex) Historic District
Commercial
Multi-Unit Residential Other
Applicant Name: Street:
Company: City:
Phone: Zip:
ITEMIZED LISTING OF PROPOSED WORK ITEMS - only listed items will be reviewed:
[Example: Replace roof shingles, Construct 2-car detached garage, etc.] Only work listed below will be considered.
Materials of work:
(Example: Type of window materials, siding, roofing, etc.)
Amount of demolition of original features/materials
square feet
APPLICATIONS ARE NOT CONSIDERED COMPLETE UNTIL ALL INFORMATION REQUIRED ON THE APPROPRIATE SUBMITTAL CHECKLIST IS SUBMITTEDI attest that no additional exterior work or window work will occur under this application (sign, and print application).
Design Review Deadline: The filing deadline is 4 weeks prior to scheduled Landmark Preservation Commission (LPC) meetings, and 23 days (3 weeks and 2 days) prior to the first Thursday of each month for the Lower Downtown Design Review Board (LDDRB). A complete application, including full supporting documentation, is due in the Landmark Preservation office by 12:00pm (noon) on the filing deadline. Landmark staff will determine whether LPC or LDDRB review is required based on adopted design guidelines. Staff will contact the applicant regarding staff comments, meeting dates (if applicable) and any additional materials that may be required.To submit electronically: Email this form and supporting materials to [email protected]. Electronic submission should include two attachments: one pdf with the completed form (“yourname-app.pdf”) and one pdf that combines all supporting materials (“yourname-app-materials.pdf”). File size should not exceed 25MB combined. Contact us if you are having trouble with your electronic submission.To submit in person: Submit this form and supporting materials to the Records Counter weekdays between 7:30am and 4:30pm on the 2nd floor of the Webb Munici-pal Building, 201 W. Colfax Ave.
All submittals become the property of the City & County of Denver. Submittals are open records.
Submittals will be posted online or made available to any party that requests a copy. 201 W. Colfax Ave., Dept. 205Denver, CO 80202
720.865.2709 or [email protected]
Landmark Preservation
Community Planning & Development
Application
3/15/16
1730 Blake Street (Hedges-Atkins Supply Co. Building)
✔ Lower Downtown
Jennifer Woods, AICP 4383 Tennyson St, Unit 1DMcCool Development Solutions Denver, CO
303.547.0072 [email protected]
Paint portion of front façade awning systemInstallation of sconcesNew address signage
Please see attached list.
N/A
Digitally signed by Jennifer Woods DN: cn=Jennifer Woods, o=McCool Development Solutions, ou, [email protected], c=US Date: 2019.11.12 11:15:57 -07'00'
4383 Tennyson Street, #1D Denver, Colorado 80212 Phone: 720.465.4320 www.mccooldevelopment.com
, 2020
ATTN: Jessica White City and County of Denver Community Planning & Development, Landmark Review 201 W. Colfax Ave., Dept. 205 Denver, CO 80202
RE: Design Review Application for Landmark Preservation, 1730 Blake St. (Hedges-Atkins Supply Co.)
Jessi,
Please find our submittal packet for distribution to the Lower Downtown Design Review Commission members for their meeting . The contents of this package include :
Complete application.
Plans, drawings and sketches depicting the project.
Details and materials list.
Color photos of existing conditions.
Thank you,
Jennifer Woods, AICP Senior Planner Office: 720.465.4320 ext.102 Direct: 303.547.0072 [email protected]
4383 Tennyson Street, #1D Denver, Colorado 80212 Phone: 720.465.4320 www.mccooldevelopment.com
Design Review Application Details and Materials List: 1730 Blake St. (Hedges-Atkins Supply Co. Building)
Sheet: Aluminum-Framed Storefront Entry System
Sheet: Elevation Downlight Sconce TYPo Fixture type: Insight Lighting: Hess Varallo 485 Downlight ONLYo Lamp type: LEDo Materials: Extruded aluminum housing with aluminum end capso Power source Integral DC Transformer/ 277Vo Wattage: 11 W/FTo Color Temperature: 3000K
Paint Color 1 & 2 Sheet: Detail of Storefront Entry
o Concealed Overhead Closero Aluminum-framed Storefront Door, Transom and Sidelights: FP
Coated (Dark Gray)o Vertical Pull: Rookwood 2610 Stainless Steelo Safety Glazing on glass (clear)o GWB Bulkhead (New and/or existing)o Dimensional letter signage, mill-finished aluminumo Fastened to HSS with Threaded Signage Studo C6 Framing (painted dark gray)
Attached Product Specifications: Varello 485 LED LCM3 LED Channel Letter Modules
BLAKE STREET
HEDGES-ATKINS SUPPLY BUILDING1730 BLAKE STREET
NEW ENTRY DOORS
NEW DOWNLIGHT SCONCE
ARCHITECTURAL SITE PLAN03/09/2020
HEDGES-ATKINS SUPPLY BUILDING1730 BLAKE STREET DENVER, CO 80202
0' ' ' ' '10 20 40 80
DAYTIME RENDERING03/09/2020
HEDGES-ATKINS SUPPLY BUILDING1730 BLAKE STREET DENVER, CO 80202
NIGHT TIME RENDERING03/09/2020
HEDGES-ATKINS SUPPLY BUILDING1730 BLAKE STREET DENVER, CO 80202
EXISTING AWNINGS TO BE REMOVED
EXISTING TENANT ENTRY TO REMAIN
1EXISTING STOREFRONT ENTRANCE TO BE REMOVED
EXISTING AWNINGS TO BE REMOVED
V.I.F3' - 1"
V.I.F
3' - 1 1/4"V.I.F3' - 1"
15' -
0 "
V.I
.F
EXISTING TENANT ENTRY TO REMAIN
EXISTING ELEVATION03/09/2020
ELEVATION 1 - NORTH
0' ' ' ' '4 8 16 32
0' ' ' ' '4 8 16 32
KEY PLAN - MAIN ENTRANCE
HEDGES-ATKINS SUPPLY BUILDING1730 BLAKE STREET DENVER, CO 80202
1
ALUMINUM-FRAMED STOREFRONT ENTRY SYSTEM
EQ6' - 0"EQ
EXISTING TENANT ENTRY TO REMAIN
9' - 3" V.I.F
V.I.
F
15' -
0 "
TO
RE
MA
IN
PLAN03/09/2020
HEDGES-ATKINS SUPPLY BUILDING1730 BLAKE STREET DENVER, CO 80202
KEY PLAN - MAIN ENTRANCE
0' ' ' ' '4 8 16 32
DOWNLIGHT SCONCE TYP
EQ
EQEQ EQ
DIMENSIONAL LETTER SIGNAGE - SEE DETAILS
PAINT COLOR 1(SEE RENDERING)
PAINT COLOR 2 (SEE RENDERING)
7' -
6"V.I.
F
11' -
0"
DOWNLIGHT ALIGN WITH SECOND FLOOR
EXISTING TENANT ENTRY TO REMAIN
NEW ELEVATION03/09/2020
ELEVATION 1 - NORTH
0' ' ' ' '4 8 16 32
LIGHT FIXTURE INFO (EXTERIOR SCONCES):
FIXTURE TYPE: INSIGHT LIGHTING: HESS VARALLO 485 DOWNLIGHT ONLYLAMP TYPE: LEDMATERIALS: EXTRUDED ALUMINUM HOUSING WITH ALUMINUM END CAPSPOWER SOURCE: INTEGRAL DC TRANSFORMER/277V WATTAGE: 11 W/FT LIGHTING INTENSITY: 2164 LM/WATTCOLOR TEMPERATURE: 3000K
9' -
6 1
/2"
VIF
9' - 3" VIF
EQ6' - 0"EQCONCEALED OVERHEAD CLOSER
ALUMINUM-FRAMED STOREFRONT DOOR, TRANSOM AND SIDELIGHTS: FP COATED (DARK GRAY - SEE RENDERING)
SAFETY GLAZING (CLEAR)
VERTICAL PULL: ROCKWOOD RM3300, STAINLESS STEEL
5' -
10"
1' -
2"
A
B
C
0' 6' 12'3"1'
INSULATED GLAZING
SEALANT BOTH SIDES
GWB BULKHEAD (NEW AND/OR EXISTING)
ALUMINUM STOREFRONT FRAMING
DEFLECTION TRACK
A
INSULATED GLAZING
SEALANT BOTH SIDES ALUMINUM
STOREFRONT FRAMINGB
0' 3" 1'6"
INSULATED GLAZING
SEALANT BOTH SIDES
ALUMINUM STOREFRONT FRAMING
C
11"
2' - 6"
DIMENSIONAL LETTER SIGNAGE, MILL-FINISHED ALUMINUM.
0' 6" 1' 2'
DETAILS03/09/2020
DETAIL OF STOREFRONT ENTRY
For the complete line of specialtyLED® products, visitus online at barronltg.com.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
Model: Date:
Accessories:
Job Name: Type:
1 of 310820069 02/15
LCM3The LCM Series LED Modules are powered by 5630 SMD LEDs encapsulated in a thermoplastic molded housing. The LCM3 utilizes three LEDs per module, offering high performance yet low operating costs for commercial signage applications. These modules can be easily manipulated, mounted on any surface and require no maintenance. The LED modules are supplied in a string of up to 50 modules that can be individually cut based on customer needs. LCMs are ideal for channel letter lighting, back and cove lighting, halo effects and accent lighting.
FEATURES
LED modules per string)
back of each module
TECHNICAL SPECIFICATION
2 of 3
WW (Warm White) WP (Pure White) WC (Cold White) R (Red)
LED / Module 3 3 3 3
CCT or Wavelength 3000K 6000K 9000K 620-625nm
Wattage per Module 1.2W 1.2W 1.2W 1.2W
Voltage 12V 12V 12V 12V
Current 100mA 100mA 100mA 100mA
Lumens / Module 94 94 94 38
Lumen Output (lm/ft) 188 188 188 76
TECHNICAL INFORMATION
Example: LCM3-WC-20
Series Color # of Modules
LCM3 WW1 = Warm White (3000K) XX2 = # of Continuous Modules
WP1 = Pure White (6000K)
WC1 = Cold White (9000K) Notes
R = Red 1 Color tempuratures can vary ±5%2
ORDERING INFORMATION
PRODUCT SPECIFICATIONS
Powered by a 5630 SMD LED chip CRI 75
aluminum PCB modules
white (9000K) and red
pre-drilled holes for a more secure installation (hardware not provided)
DIMENSIONS
3 of 3
Note: All transformers are to be installed per NEC requirements. Wire leads on the 12 volt product are 18 gauge. Transformer is to be mounted within 10 feet of product. If transformer is mounted more than 10 feet from product, voltage drop and maximum operating distances should be taken into account when making transformer selection. Dimming transformer does not include dimming controller.
Example: XFMR-DIM-12-60
Part Number Description Dimensions (AxBxC)
12VDC DIMMING TRANSFORMER ORDERING INFORMATION (ORDER AS SEPARATE LINE ITEM)
Example: XFMR-12-60
Part Number Description Dimensions (AxBxC)
12VDC NON-DIMMING TRANSFORMER ORDERING INFORMATION (ORDER AS SEPARATE LINE ITEM)
Color Photos of Existing Conditions: Front Facade
BLAKE STREET
HEDGES-ATKINS SUPPLY BUILDING1730 BLAKE STREET
03/09/2020HEDGES-ATKINS SUPPLY BUILDING1730 BLAKE STREET DENVER, CO 80202
0' ' ' ' '10 20 40 80
Main Entry 1
Main Entry 2
Main Entry 3
Main Entry 4
Secondary Entry 1(To Remain)
3
Secondary Entry 2(To Remain)