1
SOFTWARE TO HELP CHOOSING AN INFRA RENAL ABDOMINAL AORTIC ANEURYSM ENDOPROTESE Guilherme V Meirelles, Renam Alexandrino - Instituto Meirelles de Cirurgia Vascular- NO CONFLICT OF INTEREST. - NO INDUSTRY SPONSOR COMPARING THE MEASUREMENTS PROVIDE BY THE SURGEONS, WITH INDUSTRY IFU ENDOPROTESES SIZE OPTIONS (DIAMETER AND LENGTH ) RESULTING IN HOW MUCH OUR CHOICE IS AVAILABLE AND IN SIDE IFU ANEURYSM NECK ANGEL - DIAMETER - LENGTH (CLOTH - CALCIFICATION – NECK SHAPE) DISTANCE FROM INFRA RENAL TO AORTIC BIFURCATION DISTAL AORTA DIAMETER COMMON ILIAC ARTERY DIAMETER - LENGTH ACCESS - EXTERNAL ILIAC DIAMETER and tortuosity m m m m m m m m m m m m m m m m 5 POINTS OF MEASUREMENTS I F U FOR STENT GRAFTS NECK ANGLE NECK LENGTH AORFIX ≤ 90 o ≥ 15 mm INCRAFT E - TEGRA ≤ 60 o ≤ 75 o ≥ 10 mm ≥ 15 mm ENDURANT < 60 o ≤ 75 o ≥ 10 mm ≥ 15 mm POWERLINK / AFX ≤ 60 o ≥ 15 mm EXCLUDER / C3 HERCULES ≤ 60 o ≤ 60 o ≥ 15 mm ≥ 10 mm ZENITH BRAILE / LINUS ≤ 60 o ≤ 60 o ≥ 15 mm ≥ 15 mm ANACONDA ORTIC ≤ 90 o ≤ 60 o ≥ 15 mm ≥ 15 mm TRIOVANCE < 60 o ≤ 75 o ≥ 10 mm ≥ 15 mm OVATION at 13 mm - ≥ 16mm to ≤ 30mm ≤ 45 o ≤ 60 o < 10 mm ≥ 10 mm I F U FOR STENT GRAFTS ENDOPROTESE MAIN BODY LENGTH BIFURCATION DIAMETER AORFIX 81 mm ≥ 18 mm INCRAFT E-TEGRA 86 mm 80 to 100 mm ≥ 18 mm ≥ 18 mm ENDURANT 70 mm (23)- 80 mm ≥ 18 mm AFX 60 mm (+10mm) ≥ 15 mm C3 HERCULES 70–80 / 90 mm (31-35) 80 mm ≥ 18 mm ≥ 18 mm ZENITH alfa BRAILE / LINUS 70 to 128 mm 75 mm ≥ 18 mm ≥ 18 mm ANACONDA ORTIC 77 mm 80 mm ≥ 18 mm ≥ 19 mm TRIOVANCE OVATION 80 - 120mm 80 mm Extensions DiameterX 0.7 ≥ 18 mm DIAMETER MIM 7 MM MAX 25 MM LENGTH FIXATION MIN ≥ 10 MM MAX NEED >20 MM COMMON ILIAC ARTERY ACCESS EXTERNAL ILIAC DIAMETER consider 4.7 mm until 30mm CALCIFICATION 5.3 mm >34mm CLOTH TORTUOSITY ( APPROXIMATE 45 OPTIONS FOR EACH COMPANY ) OFF LABEL 10,000 to 20,000 I F U AORTA NECK DIAMETER min AORTA NECK DIAMETER max AORFIX 19 mm 29 mm INCRAFT E-TEGRA 17 mm 19 mm 31 mm 32 mm ENDURANT 19 mm 32 mm POWERLINK / AFX 18 mm 32 mm Gore C3 HERCULES 19 mm 17 mm 32 mm 30 mm ZENITH ALPHA BRAILE / LINUS 18 mm 19 mm 32 mm 29 mm ANACONDA ORTIC 16 mm 20 mm 31 mm 32 mm TRIOVANCE 16 mm 32 mm OVATION at 13 mm renal 16 mm < 30mm

COMMON ILIAC ARTERY ACCESS OFF LABEL · common iliac artery access external iliac diameter consider ≥ 4.7 mm until 30mm calcification ≥ 5.3 mm >34mm cloth tortuosity ( approximate

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: COMMON ILIAC ARTERY ACCESS OFF LABEL · common iliac artery access external iliac diameter consider ≥ 4.7 mm until 30mm calcification ≥ 5.3 mm >34mm cloth tortuosity ( approximate

SOFTWARE TO HELP CHOOSING AN INFRA RENAL ABDOMINAL AORTIC ANEURYSM ENDOPROTESE

Guilherme V Meirelles, Renam Alexandrino - Instituto Meirelles de Cirurgia Vascular- NO CONFLICT OF INTEREST. - NO INDUSTRY SPONSOR

COMPARING THE MEASUREMENTS PROVIDE BY THE SURGEONS, WITH

• INDUSTRY IFU

• ENDOPROTESES SIZE OPTIONS (DIAMETER AND LENGTH )

RESULTING IN HOW MUCH OUR CHOICE IS AVAILABLE AND IN SIDE IFU

• ANEURYSM NECK

• ANGEL - DIAMETER - LENGTH (CLOTH - CALCIFICATION – NECK

SHAPE)

• DISTANCE FROM INFRA RENAL TO AORTIC BIFURCATION

• DISTAL AORTA DIAMETER

• COMMON ILIAC ARTERY

• DIAMETER - LENGTH

• ACCESS - EXTERNAL ILIAC DIAMETER and tortuosity

m

m m

m

m

mm

m

m

m

m

m

m

m

m

m

5 POINTS OF MEASUREMENTS

I F U FOR STENT

GRAFTS

NECK ANGLE NECK LENGTH

AORFIX ≤ 90o ≥ 15 mm

INCRAFT

E - TEGRA

≤ 60o

≤ 75o

≥ 10 mm

≥ 15 mm

ENDURANT < 60o

≤ 75o

≥ 10 mm≥ 15 mm

POWERLINK / AFX ≤ 60o ≥ 15 mm

EXCLUDER / C3

HERCULES

≤ 60o

≤ 60o

≥ 15 mm ≥ 10 mm

ZENITH

BRAILE / LINUS

≤ 60o

≤ 60o

≥ 15 mm

≥ 15 mm

ANACONDAORTIC

≤ 90o

≤ 60o

≥ 15 mm ≥ 15 mm

TRIOVANCE < 60o

≤ 75o

≥ 10 mm≥ 15 mm

OVATIONat 13 mm - ≥ 16mm to ≤ 30mm

≤ 45o

≤ 60o

< 10 mm≥ 10 mm

I F U FOR

STENT

GRAFTS

ENDOPROTESE

MAIN BODY LENGTH

BIFURCATION

DIAMETER

AORFIX 81 mm ≥ 18 mm

INCRAFT

E-TEGRA

86 mm

80 to 100 mm

≥ 18 mm

≥ 18 mm

ENDURANT 70 mm (23)- 80 mm ≥ 18 mm

AFX 60 mm (+10mm) ≥ 15 mm

C3

HERCULES

70–80 / 90 mm (31-35)

80 mm

≥ 18 mm

≥ 18 mm

ZENITH alfa

BRAILE /

LINUS

70 to 128 mm

75 mm

≥ 18 mm

≥ 18 mm

ANACONDA

ORTIC

77 mm

80 mm

≥ 18 mm

≥ 19 mm

TRIOVANCE

OVATION

80 - 120mm

80 mm

Extensions DiameterX 0.7

≥ 18 mm

DIAMETER

MIM 7 MM

MAX 25 MM

LENGTH FIXATION

MIN ≥ 10 MM

MAX NEED >20 MM

COMMON ILIAC ARTERY ACCESS

EXTERNAL ILIAC

DIAMETER

consider

≥ 4.7 mm until 30mm CALCIFICATION

≥ 5.3 mm >34mm CLOTH

TORTUOSITY

( APPROXIMATE 45 OPTIONS FOR EACH

COMPANY )

OFF LABEL

10,000 to 20,000

I F U AORTA

NECK

DIAMETER

min

AORTA NECK

DIAMETER

max

AORFIX 19 mm 29 mm

INCRAFT

E-TEGRA

17 mm

19 mm

31 mm

32 mm

ENDURANT 19 mm 32 mm

POWERLINK / AFX

18 mm 32 mm

Gore C3

HERCULES

19 mm

17 mm

32 mm

30 mm

ZENITH ALPHA

BRAILE / LINUS

18 mm

19 mm

32 mm

29 mm

ANACONDAORTIC

16 mm20 mm

31 mm 32 mm

TRIOVANCE 16 mm 32 mm

OVATION at 13 mm renal

16 mm < 30mm