Ibis Medical is one of the pioneering medical equipment

companies in India, to provide high quality, affordable

neonatology equipments.

Since 2008, we have built up an impressive array of products

focusing primarily on meeting the needs of NICUs across the

country. Our success has been hard earned. We have worked

hard to continuously improve our products, by listening to our

customers, understanding their unique requirements and trying

to replicate those needs.

Our LED based phototherapies are rated among the best

performing machines in India, providing relief to babies with swift

& effective performance. Our product facilities meet

international standards and our products are certified by national

& international certification agencies.

Ibis Medical is also one of the leading manufacturers of Infant

Radiant Warmers with installations across reputed hospitals all

over India. In addition to our equipment range, we started to

providing simple yet very effective solutions for neonatologists &

nursing staff by launching our NICU Vitals range.

Ibis Medical was incubated at National Institute of Technology,

Calicut. NIT provides us with a strong R&D focused technical

support. It additionally provides us with the necessary financial

support in form of equity participation.

Page 3: Committed to Next Generation · PDF fileparent-infant bonding while in jaundice treatment. Light should cover maximum surface area Effective Surface area Should be greater than
Page 4: Committed to Next Generation · PDF fileparent-infant bonding while in jaundice treatment. Light should cover maximum surface area Effective Surface area Should be greater than

LED PHOTOTHERAPY

I Rex 10 I Rex 20

I REX 10 Provides all benefits of High Bright Blue LED

technology in compact and affordable Design

Meets AAP Guideline of Phototherapy *

Device Timer Tracking Overall usage of LED source

NO Ultraviolet / No Infrared rays which may causes skin

rashes to Hyperthermia to the infants

Low Power consumption <15 W

The effective way of Phototherapy

treatment , that is safe , gentle and easy to use

Intensity Control from 15 – 70 Micro Watt

Manual Intensity Control

Analogue Timer for LED usage monitoring

24 High Bright Blue LED for treatment

Independent White LED for Observation

Double Side option

Set your own irradiance I REX Series LED Phototherapy with Intensity control facility

Basic LED PhototherapyDouble Surface

Basic LED Phototherapywith Trolley

NEW

Enhanced Performance NEW

Ibis

Page 5: Committed to Next Generation · PDF fileparent-infant bonding while in jaundice treatment. Light should cover maximum surface area Effective Surface area Should be greater than

I Rex 30

I Rex 40

Digital Intensity Control Facility

15 – 70 Micro Watt

Patient and Total usage Timer digital Display

24 High Bright Blue LED for treatment

Independent White LED for Observation

Double Side Option available

Check and Set your desired intensity for the treatment with

Inbuilt Radiometer sensor *

IREX 40 comes with Thermistor Temperature sensor facility,

which will send out an alarm on infant's Hypo/Hyperthermia

possibility. Thus providing greater safety during baby's

treatment.

*sensor can be bought separately

The New benchmark in LED Phototherapy

IREX 30 B / IREX 40

Premium LED Phototherapy with trolley

LED PHOTOTHERAPY

Irradiance Sensor Thermistor Temp. Sensor

Ibis

Page 6: Committed to Next Generation · PDF fileparent-infant bonding while in jaundice treatment. Light should cover maximum surface area Effective Surface area Should be greater than

BLANKET PHOTOTHERAPY

IRex Blanket

Revolutionizing the phtototherapy treatment by providing

completely portable and maintenance free system.

Designed for

parent bondingAn ideal solution for

promote ‘kangaroo care’ and

parent-infant bonding while in jaundice treatment.

Light should cover maximum surface area

Effective Surface area

Should be greater than

302

mW /cm /nm

Light Intensity / Irradiance

430 490 nm -Light Wave Length

I Rex cover 40 X 25 cm surface area from underneath of the baby.

2I Rex blanket giving > 35 mW /cm /nm

450 - 475 nm

Performance factor Clinical guidelines I Rex blanket specifications

Superior PerformanceMeets International guideline for phototherapy*

Ibis

Page 7: Committed to Next Generation · PDF fileparent-infant bonding while in jaundice treatment. Light should cover maximum surface area Effective Surface area Should be greater than

Specification ICOR E 10 BD I CORE 10 T I CORE 10 B I CORE 10 Basic

Mode of opera�on - Servo and Manual √ √ √ √

Infra Red Ceramic Heater ( Quartz Heater *) √ √ √ √

Thermistor Temperature Sensor √ √ √ √

Independent Display for Set and Pa�ent Temp √ √ √Cri�cal alarms- Audio and Visual

Observa�on Lamp - LED

Apgar Timer

Count down and rese�able �mer

Inbuilt Bed

Inbuilt Tray

Inbuilt Drawer with Tray

Detachable Trolley Op�onal

√√ √ √ √√ √ √ √

√ √ √

√ √ √

√√

ICore 10 Basic

ICore 10 TWith Double Surface Phototherapy

I Core Infant warmers are incorporated with high performance processors which offer more accurate temperature sensing. The easy to use control panel, incorporates easy accessibility and greater visibility, with clear colour coded LEDs for setting desired temperatures & viewing current temperature.

Safety features include all audio-visual alarms with High temperature cutoff.

The clean straight design provides an aesthetically appealing look. The modular design also helps in engineering the warmer to meet your needs.

Technology makes affordable...

ICore 10 Series

INFANT RADIANT WARMER

ICore 10 - BD

ICore 10 B

Ibis

Page 8: Committed to Next Generation · PDF fileparent-infant bonding while in jaundice treatment. Light should cover maximum surface area Effective Surface area Should be greater than
Page 9: Committed to Next Generation · PDF fileparent-infant bonding while in jaundice treatment. Light should cover maximum surface area Effective Surface area Should be greater than

Infantometer Mat

A space saving, easy and accurate solution for baby length measuring Measuring range - 8 to 75 cm Dimension - 95 x 25 x 10 cm Wall Hanging possible Washable material

An impressive portfolio of NICU consumable requirement

NICU VITALS

Head Circumference Tape

Non stretchable ultra soft MaterialInch and centimeter measurementMeasuring range 5 - 50 cm/ 2- 20 inch Reusable Quantity : 3 Pieces / Box

Measuring Range : 1 - 70 cms / 1 - 30 inches DisposableQuantity /Box - 25 Nos Material - PaperSpace for fill patient Information

NICU VITALS

Disposable

Head Circumference Tape

Paper made disposable solutions for measuring infants head circumference.Measuring range 5 - 50 cm/ 2- 20 inch Disposable Quantity : 25 Pieces / Box

Disposable Measuring Tape

MUAC Tape

Mid upper arm circumference tape as per Unicef standard.

Measuring range upto 26.5 cm

Material: Flexible non tearable PVC

Colour code: Red 0- 11.5 cms, Yellow 11.5 - 12.5 cms, Green 12.5 - 26.5 cms

Ibis

Page 10: Committed to Next Generation · PDF fileparent-infant bonding while in jaundice treatment. Light should cover maximum surface area Effective Surface area Should be greater than

Baby Weighing Machine

Oxygen Hood

Neontal Gonad Protector

An added safety protection for Goand /Overy and an easy way to optimize the radiation dose to infant. Studies are recommending X –ray shield for newborn goand area while taking

1chest XrayUsage of Gonad pro will helps to reduce the possibility of neoplasia and gentic

2disorders occurring due to excess number of X rays

A Simple and perfect eye protector for N e o n a t a l p h o t o t h e r a p y. H i g h l y recommending green material – anti allergic and soft Single patient only

Neonatal Eye protectorI-Pro

Infant Trolley

Medium Small

Ibis Vein Viewer

A unique infant vein viewerAn easy solution for infant vein detectionRechargeable Li-ion battery Three High Bright Red LED1 year replacement guarantee

NICU VITALS

Ibis

Size : Term (without adjuster)

Size : Pre-Term (without adjuster)

Size : Universal (with adjuster)

Page 11: Committed to Next Generation · PDF fileparent-infant bonding while in jaundice treatment. Light should cover maximum surface area Effective Surface area Should be greater than

50+ Dealers250+ Hospitals

2000 + Machinesin INDIA

Gro

wth

2008 2015-16

Ibis Growing globally

Growing Satisfied Customers

Page 12: Committed to Next Generation · PDF fileparent-infant bonding while in jaundice treatment. Light should cover maximum surface area Effective Surface area Should be greater than

45/279 , Koothappady Road,

Anjumuri, Thammanam P.O., Ernakulam - 682 032, India

M: 09446507619, T: 0484 [email protected]

Ibis Medical Equipment & Systems Pvt. Ltd.

TECHNOLOGY PARTNER

NIT�CALICUT

www.ibismedical.net

Ibis

Quality Certifications

ISO 13485:2003 CertifiedCE CertifiedISO 9001-2008 Certified