2
Characteristics: • Commercial WPM is suitable for use for both internal and external waterproofing. • It is water based and safe to use with minimum odour. • For Green Building requirements - Commercial WPM is solvent free and suitable for confined areas. • It also meets the benchmark for VOC’s in the Green Building Council of Australia Ratings. • Commercial WPM complies with AS4858:2004 Q(Internal membranes) and AS4654.1:2012 (external membranes) as a Class Ill Elastomeric liquid applied membrane. • Commercial WPM may be used as an undertile exposed trafficable pedestrian membrane) and can also be used as an exposed membrane for light foot traffic applications. • Commercial WPM does not require the use of reinforcing fabric and is UV resistant. • It can be used over concrete, F/C sheet, plasterboard, timber and most building materials. • It can also be used above or below floor screeds. Preparation: • All concrete should have a wood float finish and be cured for at least 6 weeks prior to waterproofing. • Rendered surfaces should be allowed to cure for at least 7 days weeks prior to waterproofing. • All fibre cement sheets, compressed fibre cement, plasterboard structural particle board and plywood must comply with the relevant building code and be fixed in accordance with the manufacturers instructions. • All surfaces must be clean, dry, free of excessive movement, oil, dust grease, curing compounds, paint and any other loose or contaminating materials. • The surface must be smooth with no protrusions or major irregularities. • All screws and nail heads must be sealed with epoxy or a suitable sealant, (do not use acid cured silicones or waterbased products). • Hairline cracks may be filled with the first coat of Commercial WPM. Cracks up to 2mm and control joints should be filled with a suitable sealant like neutral cure silicone or P/U construction sealant and then be taped using a 50mm wide, fabric reinforced duct tape. Internal sheet joints should also be treated in the same way. • For interior concrete, render, uncoated F/C sheet and other interior absorbent substrates, use RLA Universal primer as a primer before using Commercial WPM. • Allow to dry for about 15-30 minutes. • For exterior concrete or for coated waterproof type external or internal F/C sheet use one coat of Dryflex Moisture Barrier water based epoxy as the primer. • If the concrete contains moisture use 2 coats of Dryflex Moisture Barrier (see Dryflex Moisture Barrier Data Sheet) to form an hydrostatic membrane. • Allow to dry for at least 16 hours at 25°C before applying Commercial WPM. Preparation: (continued) • At wall floor junctions,apply neutral silicone or polyurethane sealant (do not use acid cured silicone or water based sealants) to form a radiused fillet of at least 25mm diameter creating a bond breaker of at least 15mm. • Allow the sealant to “surface dry’’ before applying membrane. • On external concrete all parrapets, joints and penetrations should be detailed as described in AS4654.2:2012 - External Waterproofing. • On external sheeting, consult the manufacturers recommendations for any special instructions regarding priming and jointing, otherwise prepare in accordance with AS4654. Application: • Commercial WPM should be applied in accordance with AS3740:2010forinternal applications and in accordance with AS4654.2:2009 for external applications. • After preparing the substrate as above, use a paintbrush, roller or airless spray system to apply 2 or 3 heavy coats allowing the product to completely dry between coats. • The coating should form a seamless film that comes down the wall, across the floor and into the waste. Inspect each coat for pinholes, bubbles or defects and repair on next coat. • On flat balconies, membrane should extend over the edge and around to the drip mould. • Dry film thickness for under tile applications should be about 1.00mm after 2 coats. For use as a trafficable membrane, film thickness should be 1.5mm after 3 coats. • Protect the membrane from water, bad weather and damage until it is fully cured. Do not tile or lay screed over membrane until it is fully cured. • If water seal testing is required for more than 1 hour, allow membrane to re-dry for an extra day after draining. COMMERCIAL WPM Dryflex fibre reinforced • Waterbased polyurethane waterproofing membrane • Undertile membrane for bathrooms, balconies • Does not require reinforcing tape • Fast drying and UV stable • Complies with AS4858:2004 Class III TEN YEAR GUARANTEE

COMMERCIAL WPM - RLA Grouprlagroup.com.au/.../tds_1475710495CommercialWPMDataSheet.pdfCharacteristics: • Commercial WPM is suitable for use for both internal and external waterproofing

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: COMMERCIAL WPM - RLA Grouprlagroup.com.au/.../tds_1475710495CommercialWPMDataSheet.pdfCharacteristics: • Commercial WPM is suitable for use for both internal and external waterproofing

Characteristics:

•CommercialWPMissuitableforuseforbothinternalandexternalwaterproofing.

• Itiswaterbasedandsafetousewithminimumodour.

•ForGreenBuildingrequirements-CommercialWPMissolventfreeandsuitableforconfinedareas.

• ItalsomeetsthebenchmarkforVOC’sintheGreenBuildingCouncilofAustraliaRatings.

•CommercialWPMcomplieswithAS4858:2004Q(Internalmembranes)andAS4654.1:2012(externalmembranes)asaClassIllElastomericliquidappliedmembrane.

•CommercialWPMmaybeusedasanundertileexposedtrafficablepedestrianmembrane)andcanalsobeusedasanexposedmembraneforlightfoottrafficapplications.

•CommercialWPMdoesnotrequiretheuseofreinforcingfabricandisUVresistant.

• Itcanbeusedoverconcrete,F/Csheet,plasterboard,timberandmostbuildingmaterials.

• Itcanalsobeusedaboveorbelowfloorscreeds.

Preparation:

•Allconcreteshouldhaveawoodfloatfinishandbecuredforatleast6weekspriortowaterproofing.

•Renderedsurfacesshouldbeallowedtocureforatleast7daysweekspriortowaterproofing.

•Allfibrecementsheets,compressedfibrecement,plasterboardstructuralparticleboardandplywoodmustcomplywiththerelevantbuildingcodeandbefixedinaccordancewiththemanufacturersinstructions.

•Allsurfacesmustbeclean,dry,freeofexcessivemovement,oil,dustgrease,curingcompounds,paintandanyotherlooseorcontaminatingmaterials.

•Thesurfacemustbesmoothwithnoprotrusionsormajorirregularities.

•Allscrewsandnailheadsmustbesealedwithepoxyorasuitablesealant,(donotuseacidcuredsiliconesorwaterbasedproducts).

•HairlinecracksmaybefilledwiththefirstcoatofCommercialWPM.Cracksupto2mmandcontroljointsshouldbefilledwithasuitablesealantlikeneutralcuresiliconeorP/Uconstructionsealantandthenbetapedusinga50mmwide,fabricreinforcedducttape.Internalsheetjointsshouldalsobetreatedinthesameway.

•Forinteriorconcrete,render,uncoatedF/Csheetandotherinteriorabsorbentsubstrates,useRLAUniversalprimerasaprimerbeforeusingCommercialWPM.

•Allowtodryforabout15-30minutes.

•ForexteriorconcreteorforcoatedwaterprooftypeexternalorinternalF/CsheetuseonecoatofDryflexMoistureBarrierwaterbasedepoxyastheprimer.

• Iftheconcretecontainsmoistureuse2coatsofDryflexMoistureBarrier(seeDryflexMoistureBarrierDataSheet)toformanhydrostaticmembrane.

•Allowtodryforatleast16hoursat25°CbeforeapplyingCommercialWPM.

Preparation: (continued)•Atwallfloorjunctions,applyneutralsiliconeorpolyurethanesealant(donotuseacidcuredsiliconeorwaterbasedsealants)toformaradiusedfilletofatleast25mmdiametercreatingabondbreakerofatleast15mm.

•Allowthesealantto“surfacedry’’beforeapplyingmembrane.

•Onexternalconcreteallparrapets,jointsandpenetrationsshouldbedetailedasdescribedinAS4654.2:2012-ExternalWaterproofing.

•Onexternalsheeting,consultthemanufacturersrecommendationsforanyspecialinstructionsregardingprimingandjointing,otherwiseprepareinaccordancewithAS4654.

Application:

•CommercialWPMshouldbeappliedinaccordancewithAS3740:2010forinternalapplicationsandinaccordancewithAS4654.2:2009forexternalapplications.

•Afterpreparingthesubstrateasabove,useapaintbrush,rollerorairlessspraysystemtoapply2or3heavycoatsallowingtheproducttocompletelydrybetweencoats.

•Thecoatingshouldformaseamlessfilmthatcomesdownthewall,acrossthefloorandintothewaste.Inspecteachcoatforpinholes,bubblesordefectsandrepaironnextcoat.

•Onflatbalconies,membraneshouldextendovertheedgeandaroundtothedripmould.

•Dryfilmthicknessforundertileapplicationsshouldbeabout1.00mmafter2coats.Foruseasatrafficablemembrane,filmthicknessshouldbe1.5mmafter3coats.

•Protectthemembranefromwater,badweatheranddamageuntilitisfullycured.Donottileorlayscreedovermembraneuntilitisfullycured.

• Ifwatersealtestingisrequiredformorethan1hour,allowmembranetore-dryforanextradayafterdraining.

COMMERCIAL WPM

Dryflex fibre reinforced

•Waterbasedpolyurethanewaterproofing membrane

•Undertilemembraneforbathrooms, balconies

•Doesnotrequirereinforcing tape

• FastdryingandUVstable

•ComplieswithAS4858:2004 Class III

TENYEAR

GUARANTEE

Page 2: COMMERCIAL WPM - RLA Grouprlagroup.com.au/.../tds_1475710495CommercialWPMDataSheet.pdfCharacteristics: • Commercial WPM is suitable for use for both internal and external waterproofing

Cleanup:

•Spills,toolsandequipmentcanbecleanedwithwaterwhileCommercialWPMisstillwet.

Coverage:

•Variesgreatlydependingonsubstrateporosityandroughness.Onsmoothconcreteroughly:

•2coatsforinternaluseapprox1½Litrespersquaremetre.

•3coatsforexternaltrafficuseapprox2¼Litrespersquaremetre.

Packaging/Shelf Life:

•CommercialWPMisavailablein15Land4Lpails.

•WhenstoredunopenedinacooldryplaceCommercialWPMwillhaveashelflifeof12months.

ManualHandling:

•Manualhandlingofthispailwithoutduecareandattentionmayresultinpersonalinjury.

HandyTips:

•WaterproofingshouldbecarriedoutinaccordancewiththeappropriateAustralianStandardLargeexteriorjobsandintricateinteriorworkshouldbecarriedoutbyaprofessionalthatisfamiliarwiththesestandards

•DIYapplicatorsmayneedtoseekmoredetailedinformation.

•DonotapplyCommercialWPMintemperaturesabove35°Corbelow5°C.

•Donotusewherethereisnegativehydrostaticpressure(sealwithDryflexMoistureBarrier)

www.rlapolymers.com.auTECHNICAL ENQUIRIES TOLL FREE No.1800 752 679

Disclaimer: The information supplied is to the best of our knowledge true and accurate. The actual application of the product is beyond the manufacturers control. Any failure or damage caused by the incorrect usage of the product is not the responsibility of the manufacturer. The manufacturer insists that all workmanship must be carried out in accordance with AS 3958.1-2007. It is also the responsibility of the end user to ensure that the literature in their possession is the latest issue.

HeadOffice:

215ColchesterRd,Kilsyth,VIC3137

Ph:(03)97281644

Fax:(03)97286009

NSW:

363WentworthAve,PendleHill,NSW2145

Ph:(02)96367444Fax:(02)96367688

Queensland:

25ComputerRd,Yatala,QLD4207

Ph:(07)38074022Fax:(07)38074755

SouthAustralia:

BladeRunnerDistributors2SeaforthAve,SomertonPark,SA5044

Ph:(08)83585200Fax:(08)83585300

WesternAustralia:

Ph:1800242931

IssueDate-27.01.2015

TechnicalDataAppearance Greyviscousliquid.

BulkDensity 1.25

Re-CoatTime 4-6hours@25°C

DryingTime 12-16hours@25°C

FullCure 3days@25°C

ApplicationTemperature 5°Cto35°C

VOCContent <2grams

Elongationatbreak 350%

TensileStrength 5MPa

Min.DryFilmThickness 0.75-1.00mm(undertile) 1.20-1.50mm(exteriortraffic)

wall tile

wall board

framing

silicon sealant

silicon sealant

joist

�oor tile (goes under wall tile)

tile adhesive

screed

membrane�oor sleet

RLA �ex tape

membrane

balcony

aluminum angle

drainage �ange

drainage pipe

membrane

�oor substrate

It is preferable to rebate the drainage �ange into the substrate and glue down with silicone.

tile adhesive

RLA �ex tape

backing rod

tile

silicon sealant

membrane

wall or �oor sleet

wall tile

wall board

framing

silicon sealant

silicon sealant

joist

�oor tile (goes under wall tile)

tile adhesive

screed

membrane�oor sleet

RLA �ex tape

membrane

balcony

aluminum angle

drainage �ange

drainage pipe

membrane

�oor substrate

It is preferable to rebate the drainage �ange into the substrate and glue down with silicone.

tile adhesive

RLA �ex tape

backing rod

tile

silicon sealant

membrane

wall or �oor sleet

wall tile

wall board

framing

silicon sealant

silicon sealant

joist

�oor tile (goes under wall tile)

tile adhesive

screed

membrane�oor sleet

RLA �ex tape

membrane

balcony

aluminum angle

drainage �ange

drainage pipe

membrane

�oor substrate

It is preferable to rebate the drainage �ange into the substrate and glue down with silicone.

tile adhesive

RLA �ex tape

backing rod

tile

silicon sealant

membrane

wall or �oor sleet

•Not designed for use in planter boxes, retaining walls or below ground.•Commercal WPM is not classified as hazardous.•For a full MSDS, please contact your nearest RLA Office.