FREE5 YEARSparts & labour on all productsManufactured in the UK
GUARANTEE
Commercial Heating • Domestic Heating
twen
ty
�fth anniversary
twenty �fth anniv
ersa
ry251991-2016
Contents
Solutions for domestic & commercial applications p 4-5
Summary of product range - Commercial applications p 6-7
2 www.SmithsEP.co.uk
2. Domestic fan convectors p 32-37
3. Flame-effect fan convectors p 38-40
4. Natural convectors (perimeter heating) p 41
1. Commercial fan convectors p 8-29
5. Plinth Heaters - hydronic p 42-44
Glossary p 46
Summary of product range - Domestic applications p 30-31
6. Plinth Heaters - electric p 45
Co
nte
nts
If you require energy efficiencyand versatility in your heating,the Smith’s range of fanconvectors is the ideal solution.
3 www.SmithsEP.co.uk
Intr
od
uct
ion
Why choose Smith’s?
For over twenty-five years, Smith’s EP UK has been manufacturing andproviding an extensive range of commercial and domestic heating and watersolutions from our head office in the UK. Part of the global family-ownedUS-based business, the Swan Group, Smith’s works closely with architects,consultants, heating contractors and installers to deliver high quality fanconvectors with industry-leading warranties on time, with an aftercare andtechnical support service that is second to none.
We take an active, innovative approach to new product development andcreating bespoke heating products to fulfil the creative requirements of acompetitive and demanding customer base that spans the UK, Northern Europeand the US. We believe it’s essential to be flexible in our partnerships, whileremaining uncompromising on the high quality and care that goes into everyproduct in our range. Smith’s is an outward-looking, growing business and weare forging relationships with like-minded manufacturers across Europe toensure that we can provide additional new and essential heating or waterproducts in areas where we do not specialise and where our partners excel.
Our latest brochure showcases our principal commercial and domestic products,detailing the range of fan convectors that we provide. At the same time, wehave the ability and the will to work alongside clients at any point in theconstruction process, and collaborate to develop specific solutions for any andevery need. We take great pride and go to great lengths to leave our customersnot only satisfied but coming back again and again for heating solutions thatare perfect for your project, each and every time.
Gary Haynes MBA, B.Eng.(Hons)Managing Director
#ThinkSmiths
Solutions for domestic & commercial applications
Standard heating systems
4
How fan convectors work
Smith’s fan and flame-effect fan convectors work efficiently andeffectively with all types of wet central heating systems, includinggas, oil, electric, biomass or LPG boilers. They also require anelectrical connection to run the fan. Hot water from the centralheating system passes through the heat exchanger, transferring itsheat to the aluminium fins. Cooler air is drawn in by the fan andheated as it passes over the heat exchanger, before being expelledgently back into the room. This gives a more even temperaturespread and heats rooms in much less time than a traditional panelradiator. Each Smith’s fan convector includes a low temperaturecut-out system, preventing the product from operating until thesystem water temperature reaches a pre-set level. Electric versionsconnect to a standard electrical system via a fused spur.
Fan convectors use either AC or EC motor technology to drive thefan. AC motors typically provides the end user with a number offixed speeds whilst EC technology offers infinite control over thefan speed and heat output.
At home with Smith’s fan convectors
For a trained heating engineer, installing our fan convectors issimple because they use the same pipe work, fitting proceduresand heat loss calculations as radiators. We also provide installationguides for all our products via our website. With the heat outputswitch left on either normal or boost position, they will come onand off automatically with the central heating system. Each modelincludes a low temperature cut-out, which prevents the productoperating until the water temperature reaches a pre-settemperature. They can be used alone or paired with radiators andcan be sited almost anywhere to suit the size and style of thebuilding. Place them low on walls, above doorways or high up onother walls for safety or space considerations. Our renownedSpace Saver is designed to be sited in a plinth under a kitchenbase unit to create more storage space, worktop surface area orroom for additional white goods.
For those concerned about running costs, fan convectors use avery small amount of electricity to run the fan and/or bulb (flame-effect fan convectors only). Based on an annual usage of 1300hours with electricity charged at 15p per kWh, we calculateelectricity costs to be less than £5 per year for a fan convector andless than £10 per year for flame-effect fan convectors.
Natural Convectors(Perimeter Heating)Requiring connection to a wet central heating system, hot waterpasses through the heat exchanger, transferring its heat to thealuminium fins. The natural movement of air gently circulates overthe heat exchanger, is warmed and evenly distributed around theroom.
A typical central heating system combining condensingboiler, radiator, two EcoPowerad® fan convectors and aSpace Saver plinth heater.
www.SmithsEP.co.uk
Solu
tions
for c
omm
erci
al a
nd d
omes
tic a
pplic
atio
ns
Low temperature heating systems
5
Working with heat pumps
Renewable technology grows apace, with ground and air sourceheat pumps beginning to become a viable alternative to boilers asthe principal heat generator in homes around the UK.
Inherent in the heat pump’s design is that the smaller thetemperature difference between the heat source pump (air orground) and the heat sink/emitter (under-floor heating, fanconvector, radiator), the higher the energy efficiency of that heatpump. This higher efficiency means lower fuel bills and greatercarbon savings for that home.
Fan convectors can work very effectively at system temperatures aslow as 40°C. This allows your chosen heat pump to work close toits maximum levels of efficiency, which means it will reduce theuser’s energy costs and energy consumption in the way that it wasintended. By contrast, a standard radiator is designed to beefficient at higher temperatures, 45°C and above, whichautomatically reduces the heat pump’s efficiency by more than10%. In addition the size of the radiator has to be increasedsignificantly to cope with the lower system temperatures.
SAP* calculation comparison
An example SAP calculation shows that using a combination of anair source heat pump with a fan convector in a new build orexisting property, should show a reduction of at least 12% inrunning costs (and carbon usage) when compared with a radiatorand air source heat pump, and that using a fan convector in thisway achieves close to the efficiencies obtained by installing under-floor heating.
*The Standard Assessment Procedure (SAP) is the UK Government'srecommended method system for measuring the energy rating ofresidential dwellings.
Comparable fan convector v radiator on a low temperature system
Height Width Depth Weight
Fan convector 400mm 1210mm 95mm 14kg
Radiator 600mm 1800mm 180mm 63kg
www.SmithsEP.co.uk
Solu
tions
for c
omm
erci
al a
nd d
omes
tic a
pplic
atio
ns
Summary of product ranges - Commercial applications
6
Caspian UVEC and AC motors p8-11One heating solution for a variety ofapplications, suitable for high, low orceiling-mounted installation.Incorporating EC and AC motortechnology, the UV delivers heat quickly,efficiently and effectively. Heat outputsup to 19.2kW (65500 Btu/h).
Caspian LSTEC motors p18-19The Caspian LST is suitable for a rangeof low level installation projects in anyNHS Estates premises includinghospitals, clinics, surgeries and otherhealth care premises.
Caspian SkylineEC and AC motors p24-25Caspian Skyline fan convector fitssleekly into a 600mm x 600mm ceilingtile, providing easy access for bothinstallation and maintenance. Usingcurrent EC technology, it deliversdiscreet heating in schools, retail or foodunits and plumbs easily into the centralheating system. Heat outputs up to5.1kW(17500Btu/h).
Skyline®
AC motors p26The ceiling-mounted Skyline® providesthe perfect solution to heating largercommercial spaces. Units install simplyinto a standard 600mm x 600mmceiling tile space. There is also an all-electric model available. Heat outputsup to 5.5kW (18800 Btu/h).
Ecovector®/Sterling High AC motors p28-29Designed for unobtrusive fixing at highlevel and ideal for retail units, officesand nurseries. Both hydronic andelectric versions available plus a lowvoltage model for bathrooms. Heatoutputs up to 4.0 kW (13500 Btu/h).
SterlingElectric heaters p23Designed for unobtrusive fixing at highlevel and ideal for retail units, officesand nurseries. Heat outputs up to3.0kW. Hydronic versions available.
Caspian UVCEC and AC motors p12-17Heating only fan convector/fan coilproduct capable of being concealed onor behind walls at high or low level,within ceiling voids and on or belowfloors. Incorporating EC motortechnology the Universal delivers heatquickly, efficiently and effectively. Heatoutputs up to 14.5kW (49200 Btu/h).
Caspian HighAC motors p20-22Designed for unobtrusive fixing at highlevel, Caspian’s rapid response heatingis ideal for heating the large areas ofschools, churches, care homes, libraries,offices, and hospitals. Heat outputs upto 14.4kW (49200 Btu/h).
Sum
mar
y of
pro
duct
ran
ges
- Com
mer
cial
app
licat
ions
www.SmithsEP.co.uk/commercial
Caspian Low AC motors p20-22A floor or wall-mounted fan convectordeveloped for a diversity of applicationsin commercial installations. Available ina range of eight models and a lowsurface temperature casing for completesafety. Heat outputs up to 14.4kW(49200 Btu/h).
Caspian FFEC and AC motors p8-11Probably the most popular style ofcommercial fan convector in the UK,with EC technology and heat outputsup to 19.2kW (65500 Btu/h).
Caspian EXTEC and AC motors p8-11An extended version of FF model.Heat outputs up to 19.2kW (65500Btu/h).
Skyline E 4kWElectric heaters p27Like its hydronic sibling, this is designedfor unobtrusive fixing at high level andis ideal for retail units, showrooms andnurseries. Allows maximum use of wallspace with a safe, high-level heat source.Heat outputs up to 4.0kW. Hydronicversions available.
7
Sum
mar
y of
pro
duct
ran
ges
- Com
mer
cial
app
licat
ions
www.SmithsEP.co.uk/commercial
Applications chartDomesticRoom Best 444 Better 44 Good 4Kitchen/Utility Room Space Saver Plinth Ecovector® High Ecovector® Low Sterling High Eco-Powerad® Low
Bathroom/En-suite Space Saver Plinth Ecovector® High Sterling HighCloakroom Ecovector® High Sureline® Ecovector® Low Sterling High Eco-Powerad® Low Hall Ecovector® Vertical Ecovector® Low Sureline®
Eco-Powerad® LowLanding Ecovector® Low Ecovector® Vertical Eco-Powerad® Low Living Room/Dining Room Ecovector® Low Ecovector® Vertical Spacemaker Recessed Eco-Powerad® LowFireplace Hydroflame® Conservatory Ecovector® High Ecovector® Vertical Sterling HighBedroom Ecovector® Low Sureline® Ecovector® Vertical Eco-Powerad® LowHome Office/Study Ecovector® High Ecovector® Low Ecovector® Vertical Sterling High Eco-Powerad® Low
CommercialRoom Best 444 Better 44 Good 4Showroom Caspian UV/UVC/FF Skyline® Ceiling High Caspian Low Caspian High Ecovector® Sureline®
Caspian Skyline®
Shop Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Skyline® Sterling High
Entrance Hall/Corridor Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Sureline®
Sterling High Spacemaker Recessed
Reception Ecovector® Low Ecovector® Vertical Ecovector® High Eco-Powerad® Low Sureline® Sterling High Caspian High
Waiting Room Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Low Sterling High
Meeting Room/Hall/Club Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Skyline® Sterling High
Changing Room Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Skyline® Sterling High
Public House Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Skyline® Sterling High
Place of Worship Caspian UV/UVC/FF/EXT Ecovector® Low Ecovector® Vertical Caspian High Eco-Powerad® Low Sureline®
Caspian Low
School, Nursery Caspian UV/UVC/FF/EXT Skyline® Ceiling Ecovector® High Caspian LST/LL/HL Caspian High Sterling High Caspian Skyline® Sterling High
Care Home, Hospital Caspian UV/UVC/FF Skyline® Ceiling Ecovector® High Caspian Universal LST Caspian High Sterling High Caspian Skyline® Sterling High Sureline®
Library Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Low Caspian High Ecovector® High Eco-Powerad® Low Caspian Skyline® Sterling High
8
1. Commercial fan convectors
CaspianCaspian by Smith’s is a range of fan convectors suitable for all kinds of commercialapplications, from churches to office developments, with the ability rapidly heat largeareas with much greater efficiency than other heat emitters. Caspian fan convectors areboth a practical and high quality heating solution for any commercial project.
Incorporating the latest EC motor technology, which can result in running-cost savings ashigh as 80%, and with variable speed control as standard, the Caspian delivers heatquickly and quietly. AC motor models are available on request.
Like all Smith’s fan convectors, Caspians are compatible with most types of wet centralheating systems, functioning equally efficiently with conventional boilers, biomasstechnology or ground or air source heat pumps.
1.Co
mm
erci
al f
an c
onve
ctor
s
www.SmithsEP.co.uk/commercial
Caspian UV, FF and EXT
Motor
EC or AC
EC motors are BMS compliant
Finish
Casing: zinc-coated steel 1.2mm. Polyester powdercoated: white RAL 9010
Available to special order in any colour
Available with anti-microbial or anti-bacterial paint
Filter
Class G3, 100% polyester, non-washable
Installation
• Suitable for two-pipe central heating systems
• Maximum installation height for high or ceiling mounting - 4m to underside
• Pipework access holes on the rear and underside
• Key operated front access panels
• Bleed valve accessible on removal of front casing
• Unit must be earthed
Commissioning
Check water is hot enough to activate the low temperature cut-outthermostat
Controls
Variable heat output controller (mounted within the product)
Accessories
External control harness (for up to 4 products)
Plinth (150mm high) to suit each model, available in black or white
Adjustable low temperature cut-out (30°C to 90°C)
Wall mounted room thermostat
Proportional heat output controller
22mm flexible hoses (pair)
External controlharness
Plinth
Adjustable lowtemperaturecut-out
Wall mounted roomthermostat
Proportional heatoutput controller
22mm flexible hosesSee Glossary on page 46 for further information on Accessories
Principal Accessories
Caspian UV Caspian FF
Caspian EXT
9
Heat Output testing based on BS EN442 using mean water temperature, 18°C entering air temperature, 10 deg temperature drop.
Model Heat Output at 80° Heat Output at 75° Heat Output at 70°
Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)
Caspian 60 3.2 (10900) 4.5 (15500) 5.9 (20000) 2.9 (9900) 4.1 (14000) 5.3 (18100) 2.6 (8800) 3.7 (12500) 4.8 (16200)
Caspian 90 5.2 (17700) 7.8 (26500) 10.3 (35200) 4.8 (16300) 7.2 (24600) 9.6 (32800) 4.4 (15000) 6.7 (22700) 8.9 (30400)
Caspian 120 6.7 (22700) 10.7 (36500) 14.5 (49400) 6.1 (20937) 9.6 (32968) 13.2 (45000) 5.6 (19100) 8.7 (29800) 11.9 (40600)
Caspian 150 14.8 (50500) 15.4 (52500) 16.2 (55300) 13.7 (46700) 14.2 (48500) 15.2 (51900) 12.5 (42700) 13.1 (44700) 14.0 (47800)
Caspian 180 17.2 (58700) 18.2 (62100) 19.2 (65500) 16.2 (55300) 17.0 (58000) 18.0 (61400) 14.9 (50800) 15.7 (53600) 16.7 (57000)
Model Heat Output at 65° Heat Output at 60° Heat Output at 55°
Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)
Caspian 60 2.3 (7800) 3.2 (11100) 4.2 (14300) 2.0 (6800) 2.8 (9600) 3.6 (12400) 1.7 (5800) 2.4 (8200) 3.1 (10600)
Caspian 90 3.9 (13500) 6.0 (20400) 8.0 (27300) 3.5 (11900) 5.3 (18000) 7.1 (24200) 3.0 (10400) 4.6 (15800) 6.2 (21100)
Caspian 120 4.9 (16600) 7.7 (26400) 10.6 (36200) 4.1 (14100) 6.8 (23200) 9.4 (32000) 3.4 (11600) 5.8 (19700) 8.1 (27700)
Caspian 150 11.3 (38600) 11.9 (40600) 12.8 (43700) 9.9 (33800) 10.8 (36900) 11.6 (39600) 8.8 (30000) 9.7 (33100) 10.4 (35500)
Caspian 180 13.6 (46400) 14.4 (49100) 15.4 (52500) 12.4 (42300) 13.3 (45400) 14.1 (48100) 11.3 (38600) 12.0 (40900) 12.8 (43700)
Model Heat Output at 50° Heat Output at 45° Heat Output at 40°
Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)
Caspian 60 1.4 (4800) 2.0 (6800) 2.5 (8700) 1.1 (3800) 1.5 (5100) 1.9 (6300) 0.8 (2700) 1.0 (3400) 1.2 (4000)
Caspian 90 2.6 (8800) 3.9 (13400) 5.3 (18000) 2.0 (7000) 3.1 (10500) 4.1 (14000) 1.5 (5100) 2.2 (7500) 2.9 (10000)
Caspian 120 2.7 (9000) 4.8 (16300) 6.9 (23500) 2.0 (6700) 3.7 (12600) 5.4 (18400) 1.3 (4400) 2.6 (8900) 3.9 (13400)
Caspian 150 7.5 (25600) 8.2 (28000) 9.0 (30700) 6.2 (21200) 6.9 (23500) 7.5 (25600) 4.8 (16400) 5.4 (18400) 6.1 (21800)
Caspian 180 9.8 (33400) 10.5 (35800) 11.2 (38200) 8.4 (28700) 9.1 (31100) 9.4 (32100) 6.6 (22500) 7.3 (24900) 7.8 (26600)
Model Total Power Consumption
Flow & Return Mains Flexible Isolation Fused Low Medium High Water CapacityConnections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Watts) (Litres)
Caspian 60 22mm n/a n/a n/a n/a 3A 8 24 40 0.92
Caspian 90 22mm n/a n/a n/a n/a 3A 15 43 70 1.50
Caspian 120 22mm n/a n/a n/a n/a 3A 13 62 110 2.08
Caspian 150 22mm n/a n/a n/a n/a 3A 20 144 177 2.54
Caspian 180 22mm n/a n/a n/a n/a 3A 26 124 220 3.18
Model Sound Levels
High Medium Low Casting Fan(dBA) (dBA) (dBA) Colour Only
Caspian 60 50 42 33 White n/a
Caspian 90 53 42 34 White n/a
Caspian 120 58 46 35 White n/a
Caspian 150 59 47 36 White n/a
Caspian 180 59 48 38 White n/a
Correction factors
Mean Water Temperature °C
EATºC 80 to 40
15 1.10
21 0.93
Temperature Drop °C
20 15 10 5
Factor 0.89 0.95 1.00 1.04
Measured at 3m in front of floor mounted model.
Model Packed Weight Caspian UV 60 23KG Caspian UV 90 36KG Caspian UV 120 45KG Caspian UV 150 60KG Caspian UV 180 78KG
1.Co
mm
erci
al f
an c
onve
ctor
s
www.SmithsEP.co.uk/commercial
Model Packed Weight Caspian FF 60 24KG Caspian FF 90 39KG Caspian FF 120 46KG Caspian FF 150 61KG Caspian FF 180 76KG
Model Packed Weight Caspian EXT 60 30KG Caspian EXT 90 49KG Caspian EXT 120 58KG Caspian EXT 150 76KG Caspian EXT 180 95KG
1. Commercial fan convectors
10
1. Commercial fan convectors
Caspian
1.Co
mm
erci
al f
an c
onve
ctor
s
www.SmithsEP.co.uk/commercial
Caspian EXT
Caspian FF
Our active, innovative approach to new product development gives us the ability tocreate bespoke heating products for our clients and partners, developing specific one-offfan convector solutions for the demands of your project, should you require.
The Caspian range of fan convectors includes the UV, suitable for all locations, the FF,probably the most popular style of commercial fan convector in the UK, and the EXT, anextended FF model.
11
Caspian UV mounted low Caspian UV mounted high Caspian UV ceiling-mounted
1.Co
mm
erci
al f
an c
onve
ctor
s
www.SmithsEP.co.uk/commercial
Caspian diagrams showing different options
The Caspian UV, one heating solution, suitable for high, low or ceiling-mountedapplications, you can even turn it upside down.
Caspian UV
1. Commercial fan convectors
12
1. Commercial fan convectors
Caspian UVC
The Caspian UVC fan convector was developed for recessed or concealed heatingprojects. This is another versatile heating solution from Smith’s, suitable for high, low orceiling concealed installations and the UVC can even be turned upside down.
Compatible with all types of wet central heating systems and any commercial or domesticair source heat pump project, the Caspian UVC has four different main accessories. Theyfunction together in any combination to create the recessed or concealed heatingsolution required, depending on the project specification. AC motor models are availableon request.
The four main accessories (see p14) comprise: spigot inlet/outlets; cranked ducts, 90° forleft or right-handed use; a 1m adjustable straight air inlet/outlet duct, which can be usedalone or with additional lengths; and an inlet/outlet grille.
www.SmithsEP.co.uk/commercial
1.Co
mm
erci
al f
an c
onve
ctor
s
Listed buildings, including places of worship, hotels and stately homes can benefit from the Caspian UVC
13 www.SmithsEP.co.uk/commercial
1.Co
mm
erci
al f
an c
onve
ctor
s
Heat Output testing based on BS EN442 using mean water temperature, 18°C entering air temperature, 10 deg temperature drop.
Model Heat Output at 80° Heat Output at 75° Heat Output at 70°
Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)
Caspian UVC 60 3.2 (10900) 4.5 (15500) 5.9 (20000) 2.9 (9900) 4.1 (14000) 5.3 (18100) 2.6 (8800) 3.7 (12500) 4.8 (16200)
Caspian UVC 90 5.2 (17700) 7.8 (26500) 10.3 (35200) 4.8 (16300) 7.2 (24600) 9.6 (32800) 4.4 (15000) 6.7 (22700) 8.9 (30400)
Caspian UVC 120 6.7 (22700) 10.7 (36500) 14.5 (49400) 6.1 (20937) 9.6 (32968) 13.2 (45000) 5.6 (19100) 8.7 (29800) 11.9 (40600)
Caspian UVC 150 14.8 (50500) 15.4 (52500) 16.2 (55300) 13.7 (46700) 14.2 (48500) 15.2 (51900) 12.5 (42700) 13.1 (44700) 14.0 (47800)
Caspian UVC 180 17.2 (58700) 18.2 (62100) 19.2 (65500) 16.2 (55300) 17.0 (58000) 18.0 (61400) 14.9 (50800) 15.7 (53600) 16.7 (57000)
Model Heat Output at 65° Heat Output at 60° Heat Output at 55°
Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)
Caspian UVC 60 2.3 (7800) 3.2 (11100) 4.2 (14300) 2.0 (6800) 2.8 (9600) 3.6 (12400) 1.7 (5800) 2.4 (8200) 3.1 (10600)
Caspian UVC 90 3.9 (13500) 6.0 (20400) 8.0 (27300) 3.5 (11900) 5.3 (18000) 7.1 (24200) 3.0 (10400) 4.6 (15800) 6.2 (21100)
Caspian UVC 120 4.9 (16600) 7.7 (26400) 10.6 (36200) 4.1 (14100) 6.8 (23200) 9.4 (32000) 3.4 (11600) 5.8 (19700) 8.1 (27700)
Caspian UVC 150 11.3 (38600) 11.9 (40600) 12.8 (43700) 9.9 (33800) 10.8 (36900) 11.6 (39600) 8.8 (30000) 9.7 (33100) 10.4 (35500)
Caspian UVC 180 13.6 (46400) 14.4 (49100) 15.4 (52500) 12.4 (42300) 13.3 (45400) 14.1 (48100) 11.3 (38600) 12.0 (40900) 12.8 (43700)
Model Heat Output at 50° Heat Output at 45° Heat Output at 40°
Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)
Caspian UVC 60 1.4 (4800) 2.0 (6800) 2.5 (8700) 1.1 (3800) 1.5 (5100) 1.9 (6300) 0.8 (2700) 1.0 (3400) 1.2 (4000)
Caspian UVC 90 2.6 (8800) 3.9 (13400) 5.3 (18000) 2.0 (7000) 3.1 (10500) 4.1 (14000) 1.5 (5100) 2.2 (7500) 2.9 (10000)
Caspian UVC 120 2.7 (9000) 4.8 (16300) 6.9 (23500) 2.0 (6700) 3.7 (12600) 5.4 (18400) 1.3 (4400) 2.6 (8900) 3.9 (13400)
Caspian UVC 150 7.5 (25600) 8.2 (28000) 9.0 (30700) 6.2 (21200) 6.9 (23500) 7.5 (25600) 4.8 (16400) 5.4 (18400) 6.1 (21800)
Caspian UVC 180 9.8 (33400) 10.5 (35800) 11.2 (38200) 8.4 (28700) 9.1 (31100) 9.4 (32100) 6.6 (22500) 7.3 (24900) 7.8 (26600)
Model Total Power Consumption
Flow & Return Mains Flexible Isolation Fused Low Medium High Water CapacityConnections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Watts) (Litres)
Caspian UVC 60 22mm n/a n/a n/a n/a 3A 8 24 40 0.92
Caspian UVC 90 22mm n/a n/a n/a n/a 3A 15 43 70 1.50
Caspian UVC 120 22mm n/a n/a n/a n/a 3A 13 62 110 2.08
Caspian UVC 150 22mm n/a n/a n/a n/a 3A 20 144 177 2.54
Caspian UVC 180 22mm n/a n/a n/a n/a 3A 26 124 220 3.18
Model Sound Levels
High Medium Low Casting Fan(dBA) (dBA) (dBA) Colour Only
Caspian UVC 60 50 42 33 White n/a
Caspian UVC 90 53 42 34 White n/a
Caspian UVC 120 58 46 35 White n/a
Caspian UVC 150 59 47 36 White n/a
Caspian UVC 180 59 48 38 White n/a
Correction factors
Mean Water Temperature °C
EATºC 80 to 40
15 1.10
21 0.93
Temperature Drop °C
20 15 10 5
Factor 0.89 0.95 1.00 1.04
Measured at 3m in front of floor mounted model.
Model Packed Weight Caspian UVC 60 23KG Caspian UVC 90 36KG Caspian UVC 120 45KG Caspian UVC 150 60KG Caspian UVC 180 78KG
1. Commercial fan convectors
1. Commercial fan convectors
Caspian UVC
14 www.SmithsEP.co.uk/commercial
Caspian UVC
Motor
EC or AC
EC motors are BMS compliant
Finish
Casing: galvanised steel 1.2mm
Filter
Class G3, 100% polyester, non-washable
Installation
• Suitable for two-pipe central heating systems
• Unit must be earthed
Commissioning
Check water is hot enough to activate the low temperature cut-out
thermostat
Controls
Variable heat output controller (mounted within the product)
Accessories
• Adjustable low temperature cut-out (30°C to 90°C)
• External control harness (for up to four products)
• Proportional heat output controller
• 22mm flexible hoses (pair)
• White powder-coated steel inlet/outlet grille
• Anodised aluminium air inlet/outlet grille
• 90°C cranked air inlet/outlet duct
• 1m adjustable straight air inlet/outlet extension duct
• Circular spigot air inlet/outlet duct
External control harness
Adjustable lowtemperature cut-out
Proportional heat outputcontroller
Principal Accessories
22mm flexible hoses
90° cranked air inlet/outletCircular spigot airlet/outlet duct
Powder-coated steel inlet/outlet grille
1m adjustable straight airinlet/outlet extension duct
Anodised aluminium inlet/outlet grille
See Glossary on page 46 for further information on Accessories
1.Co
mm
erci
al f
an c
onve
ctor
s
15 www.SmithsEP.co.uk/commercial
UVC90 A = 818
B = 638
UVC 120 A = 1118
B = 938
529
70 AD
J.
'A'63'B'
5789 71
'B'
PIPE CENTRES
ELECTRICAL SUPPLYIN THIS SIDE
314205
76 238
205
ELECTRICAL SUPPLYIN THIS SIDE
46112
1 metre straight air inlet outletextension duct
UVC90 A = 640
B = 632
UVC120 A = 940
B = 932
'B'
'A'
231.3
1000
208
204
UVC90 A = 641
UVC120 A = 941
'A'
207
301
301
206
90° cranked airinlet outlet duct
Anodised aluminiuminlet outlet grille
UVC90 A = 675
B = 614
UVC120 A = 975
B = 914
Louvre Panel R90
'A'
245
222
Ø6.0
87.5 11.5
184
'B'
32
944
232
300 300172
117
Ø197
51
64
Circular spigot air inlet/outlet duct
All dimensions in mm
UVC120 A = 961
'A'
233
7
1.Co
mm
erci
al f
an c
onve
ctor
s
Powder coated steel inletoutlet grille
MAIN UNIT DIMENSIONS
MODEL A BUVC60 518 338UVC90 818 638UVC120 1118 938UVC150 1418 1238UVC180 1718 1538
90º CRANKED DUCT
MODEL AUVC60 341UVC90 641UVC120 941UVC150 1241UVC180 1541
1 METRE STRAIGHT DUCT
MODEL A BUVC60 518 338UVC90 818 638UVC120 1118 938UVC150 1418 1238UVC180 1718 1538
ALUMINIUM GRILLE
MODEL A BUVC60 375 314UVC90 675 614UVC120 975 914UVC150 1275 1214UVC180 1575 1514
CIRCULAR SPIGOT DUCT
MODEL A DUCTSUVC60 344 1UVC90 644 2UVC120 944 3UVC150 1244 4UVC180 1544 5
STEEL GRILLE
MODEL AUVC60 361UVC90 661UVC120 961UVC150 1261UVC180 1561
1. Commercial fan convectors
16
1. Commercial fan convectors
www.SmithsEP.co.uk/commercial
The Caspian UVC can be installed either on or behind walls at high and low level, inceiling voids and on or under floors. Detailed below are a number of applicationoptions than can be achieved with the Caspian UVC and Accessories. If in doubtplease contact us.
Caspian UVC
Floor mounted application
Air outlet
Air inlet option
Reversible
1.Co
mm
erci
al f
an c
onve
ctor
s
Suspended with spigots application
Suspended with ducts application
17
Air outlet
Air inlet option
Reversible
www.SmithsEP.co.uk/commercial
1.Co
mm
erci
al f
an c
onve
ctor
s1. Commercial fan convectors
18
1. Commercial fan convectors
Caspian LST
www.SmithsEP.co.uk/commercial
1.Co
mm
erci
al f
an c
onve
ctor
s
The LST solution for all properties under the Registered Homes Act 1984.
Smith’s Caspian LST fan convector fully complies with the NHS Estates Health GuidanceNotes, "Safe hot water and surface temperatures" (formally known as DN4) and itsoperation and compliance has been independently verified by BSRIA.
The Caspian LST is suitable for a range of low level installation projects in any NHSEstates premises including hospitals, clinics, surgeries and other health care premiseswhere heat emitters whose maximum surface temperature does not exceed 43°C arerequired.
Incorporating the latest EC motor technology, the three models (120, 90 and 60) are allhydronic and plumb into any wet two-pipe central heating system whether conventionalor renewable. The Caspian LST delivers heat quickly, efficiently and effectively and thereis also a range of additional controls and accessories available, as required.
Heat Output testing based on BS EN442 using mean water temperature, 18°C entering air temperature, 10 deg temperature drop.
Model Heat Output at 80° Heat Output at 75° Heat Output at 70°
Low Medium High Low Medium High Low Medium High kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Caspian LST 60 1.0 (3400) 1.6 (5400) 2.2 (7400) 0.9 (3200) 1.4 (4900) 1.9 (6600) 0.8 (2900) 1.3 (4400) 1.7 (5900)
Caspian LST 90 3.0 (10200) 3.5 (11800) 3.9 (13400) 2.8 (9600) 3.2 (11100) 3.7 (12600) 2.6 (9000) 3.0 (10400) 3.5 (11800)
Caspian LST 120 5.0 (17000) 5.3 (18300) 5.7 (19500) 4.7 (16000) 5.1 (17300) 5.5 (18600) 4.4 (15100) 4.8 (16400) 5.2 (17700)
Caspian LST 150 6.2 (21200) 6.7 (22900) 7.2 (24600) 6.0 (20500) 6.5 (22200) 7.0 (23900) 5.7 (19400) 6.2 (21200) 6.7 (22900)
Caspian LST 180 7.7 (26300) 8.2 (28000) 8.7 (29700) 7.5 (25600) 8.0 (27300) 8.5 (29000) 7.2 (24600) 7.7 (26300) 8.2 (28000)
Model Heat Output at 65° Heat Output at 60° Heat Output at 55°
Low Medium High Low Medium High Low Medium High kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Caspian LST 60 0.8 (2600) 1.1 (3900) 1.5 (5100) 0.7 (2400) 1.0 (3400) 1.3 (4400) 0.6 (2200) 0.8 (2900) 1.1 (3600)
Caspian LST 90 2.4 (8100) 2.8 (9500) 3.2 (10800) 2.1 (7300) 2.5 (8500) 2.9 (9800) 1.9 (6400) 2.2 (7600) 2.6 (8800)
Caspian LST 120 4.0 (13700) 4.4 (15100) 4.8 (16500) 3.6 (12200) 4.0 (13700) 4.4 (15200) 3.2 (10800) 3.6 (12300) 4.1 (13900)
Caspian LST 150 5.3 (18100) 5.8 (19800) 6.3 (21500) 4.9 (16700) 5.4 (18400) 5.9 (20100) 4.6 (15700) 5.1 (17400) 5.6 (19100)
Caspian LST 180 6.8 (23200) 7.3 (24900) 7.8 (26600) 6.4 (21800) 6.9 (23500) 7.4 (25300) 6.1 (20800) 6.6 (22500) 7.1 (24200)
Model Heat Output at 50°
Low Medium High kW (Btu/h) kW (Btu/h) kW (Btu/h)
Caspian LST 60 0.6 (1900) 0.7 (2400) 0.8 (2900)
Caspian LST 90 1.6 (5600) 2.0 (6700) 2.3 (7800)
Caspian LST 120 2.8 (9400) 3.2 (10900) 3.7 (12600)
Caspian LST 150 4.2 (14300) 4.7 (16000) 5.2 (17700)
Caspian LST 180 5.7 (19400) 6.2 (21200) 6.7 (22900)
Caspian LST
19 www.SmithsEP.co.uk/commercial
1.Co
mm
erci
al f
an c
onve
ctor
s
Caspian LSTMotor
EC only
EC motors are BMS compliant
Finish
Casing: zinc-coated steel 1.2mm. Polyester powdercoated: white RAL 9010
Available to special order in any colour
Available with anti-microbial or anti-bacterial paint
Filter
Class G3, 100% polyester, non-washable
Installation
• Suitable for two-pipe central heating systems
• Pipework access holes on the rear and underside
• Key operated front access panels
• Bleed valve accessible on removal of front casing
• Unit must be earthed
Commissioning
Check water is hot enough to activate the low temperature cut-outthermostat
Regulate the flow to achieve maximum performance
Controls
Variable heat output controller (mounted within the product)
Built-in room thermostat
Fan-only
Accessories
External control harness (for up to 4 products)
Plinth (150mm high) to suit each model, available in black or white
Wall mounted room thermostat
22mm flexible hoses (pair)
Caspian LST
Model Total Power Consumption
Flow & Return Mains Flexible Isolation Fused Low Medium High Water CapacityConnections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Watts) (Litres)
Caspian LST 60 22mm n/a n/a n/a n/a 3A 26 41 55 0.92
Caspian LST 90 22mm n/a n/a n/a n/a 3A 33 59 85 1.5
Caspian LST 120 22mm n/a n/a n/a n/a 3A 33 79 125 2.08
Caspian LST 150 22mm n/a n/a n/a n/a 3A 50 119 188 2.58
Caspian LST 180 22mm n/a n/a n/a n/a 3A 66 158 250 3.18
Model Sound Levels
High Medium Low Casting Fan(dBA) (dBA) (dBA) Colour Only
Caspian LST 60 50 43 35 White •
Caspian LST 90 53 45 37 White •
Caspian LST 120 57 48 38 White •
Caspian LST 150 59 47 36 White •
Caspian LST 180 59 47 36 White •
External controlharness
Measured at 3m in front of floor mounted model.
Plinth Wall mounted roomthermostat
22mm flexible hoses
All dimensions in mm
Model A B 60 595 470 90 895 770 120 1195 1070 150 1495 1370 180 1795 1670
Model Packed Weight Caspian LST 60 24KG Caspian LST 90 37KG Caspian LST 120 46KG Caspian LST 150 60KG Caspian LST 180 78KG
Model Pressure Drop
High Medium Low(kPa) (kPa) (kPa)
Caspian LST 60 1.5 1.1 0.9
Caspian LST 90 3.9 2.3 1.6
Caspian LST 120 7.3 5.5 5.3
Caspian LST 150 8.6 6.8 6.2
Caspian LST 180 11.3 8.6 7.9
EAT 20°C, MWT 75°C, 10°C temperature drop
1. Commercial fan convectors
20
Caspian High & Low
Model Heat Output at 80ºC Heat Output at 75ºC Low Medium High Low Medium High Low Level High Level kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Caspian LL 60/03 Caspian HL 60/03 3.2 (10900) 3.5 (12000) 3.7 (12800) 2.9 (9900) 3.2 (11000) 3.4 (11600)
Caspian LL 60/04 Caspian HL 60/04 4.0 (13500) 4.5 (15400) 5.1 (17300) 3.6 (12300) 4.1 (14000) 4.6 (15700)
Caspian LL 90/06 Caspian HL 90/06 6.2 (21100) 6.8 (23300) 7.4 (25100) 5.6 (19100) 6.2 (21200) 6.7 (22900
Caspian LL 90/07 Caspian HL 90/07 6.8 (23300) 7.7 (26300) 8.6 (29300) 6.2 (21200 7.0 (23900) 7.8 (26600)
Caspian LL 120/10 Caspian HL 120/10 9.5 (32300) 11.4 (39000) 12.5 (42800) 8.6 (29300) 10.4 (35500) 11.4 (38900)
Caspian LL 120/11 Caspian HL 120/11 10.5 (35700) 12.5 (42800) 13.4 (45800) 9.5 (32400) 11.4 (38900) 12.2 (41600)
Caspian LL 120/12 Caspian HL 120/12 11.4 (39000) 13.4 (45800) 14.4 (49200) 10.4 (35500) 12.2 (41600) 13.1 (44700)
Model Heat Output at 70ºC Heat Output at 65ºC Low Medium High Low Medium High Low Level High Level kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Caspian LL 60/03 Caspian HL 60/03 2.6 (8800) 2.8 (9700) 3.0 (10300) 2.3 (7800) 2.5 (8600) 2.7 (9200)
Caspian LL 60/04 Caspian HL 60/04 3.2 (10900) 3.6 (12500) 4.1 (14000) 2.8 (9700) 3.2 (11000) 3.6 (12400)
Caspian LL 90/06 Caspian HL 90/06 5.0 (17000) 5.5 (18800) 6.0 (20300) 4.4 (15100) 4.9 (16700) 5.3 (18100)
Caspian LL 90/07 Caspian HL 90/07 5.5 (18800) 6.2 (21300) 6.9 (23700) 4.9 (16700) 5.5 (18900) 6.2 (21000)
Caspian LL 120/10 Caspian HL 120/10 7.7 (26100) 9.3 (31600) 10.1 (34600) 6.8 (23200) 8.2 (28000) 9.0 (30700)
Caspian LL 120/11 Caspian HL 120/11 8.5 (28800) 10.1 (34600) 10.9 (37000) 7.5 (25600) 9.0 (30700) 9.6 (32900)
Caspian LL 120/12 Caspian HL 120/12 9.3 (31600) 10.9 (37000) 11.7 (39800) 8.2 (28000) 9.6 (32900) 10.3 (35300)
Caspian low surface temperature fan convectors have been specially developed for awide range of applications in larger spaces and commercial environments. With the abilityto rapidly heat large areas at low cost, Caspian commercial fan convectors are bothpractical and energy efficient. Fully compatible with renewable energy technology, suchas ground and air source heat pumps, Caspian can also enhance your environmentalcredentials. Supplied as standard in white but can be supplied in any colour.
Low Level
High Level
www.SmithsEP.co.uk/commercial
Model Heat Output at 60ºC Heat Output at 55ºC Low Medium High Low Medium High Low Level High Level kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Caspian LL 60/03 Caspian HL 60/03 2.0 (6900) 2.2 (7500) 2.3 (8000) 1.7 (6000) 1.9 (6600) 2.0 (7000)
Caspian LL 60/04 Caspian HL 60/04 2.5 (8500) 2.8 (9700) 3.2 (10800) 2.2 (7300) 2.5 (8400) 2.8 (9400)
Caspian LL 90/06 Caspian HL 90/06 3.9 (13200) 4.3 (14600) 4.6 (15800) 3.4 (11500) 3.7 (12700) 4.0 (13700)
Caspian LL 90/07 Caspian HL 90/07 4.3 (14600) 4.8 (16500) 5.4 (18400) 3.7 (12700) 4.2 (14300) 4.7 (16000)
Caspian LL 120/10 Caspian HL 120/10 5.9 (20200) 7.2 (24500) 7.9 (26800) 5.2 (17600) 6.2 (21300) 6.8 (23400)
Caspian LL 120/11 Caspian HL 120/11 6.6 (22400) 7.9 (26900) 8.4 (28700) 5.7 (19500) 6.8 (23300) 7.3 (25000)
Caspian LL 120/12 Caspian HL 120/12 7.2 (24500) 8.4 (28700) 9.0 (30800) 6.2 (21300) 7.3 (25000) 7.9 (26800)
1. Commercial fan convectors1.
Com
mer
cial
fan
con
vect
ors
21
Model Total Power Consumption Flow & Return Mains Flexible Isolating Fused Low Medium High Water Capacity Low Level High Level Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Watts) (Litres)
Hydronic
Caspian LL 60/03 Caspian HL 60/03 22mm n/a n/a n/a n/a 3A 29 36 51 0.56
Caspian LL 60/04 Caspian HL 60/04 22mm n/a n/a n/a n/a 3A 29 36 51 0.92
Caspian LL 90/06 Caspian HL 90/06 22mm n/a n/a n/a n/a 3A 53 60 98 0.72
Caspian LL 90/07 Caspian HL 90/07 22mm n/a n/a n/a n/a 3A 53 60 98 1.50
Caspian LL 120/10 Caspian HL 120/10 22mm n/a n/a n/a n/a 3A 53 99 114 2.08
Caspian LL 120/11 Caspian HL120/11 22mm n/a n/a n/a n/a 3A 60 114 135 2.08
Caspian LL 120/12 Caspian HL 120/12 22mm n/a n/a n/a n/a 3A 99 135 151 2.08
Model Sound Levels High Medium Low Casing Low Level High Level (dBA) (dBA) (dBA) Colour Fan-Only
Hydronic
Caspian LL 60/03 Caspian HL 60/03 40 37 34 White n/a
Caspian LL 60/04 Caspian HL 60/04 38 35 32 White n/a
Caspian LL 90/06 Caspian HL 90/06 43 40 37 White n/a
Caspian LL 90/07 Caspian HL 90/07 42 40 37 White n/a
Caspian LL 120/10 Caspian HL 120/10 44 42 37 White n/a
Caspian LL 120/11 Caspian HL 120/11 46 44 39 White n/a
Caspian LL 120/12 Caspian HL 120/12 48 46 42 White n/a Sound levels measured at 1.5m.
www.SmithsEP.co.uk/commercial
Model Heat Output at 50ºC Heat Output at 45ºC Low Medium High Low Medium High Low Level High Level kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Caspian LL 60/03 Caspian HL 60/03 1.5 (5100) 1.6 (5600) 1.7 (5900) 1.2 (3950) 1.3 (4350) 1.4 4650)
Caspian LL 60/04 Caspian HL 60/04 1.8 (6250) 2.1 (7100) 2.3 (8000) 1.4 (4900) 1.6 (5600) 1.8 (6300)
Caspian LL 90/06 Caspian HL 90/06 2.9 (9700) 3.2 (10800) 3.4 (11700) 2.2 (7600) 2.5 (8500) 2.7 (9100)
Caspian LL 90/07 Caspian HL 90/07 3.2 (10800) 3.6 (12200) 4.0 (13600) 2.5 (8500) 2.8 (9600) 3.1 (10600)
Caspian LL 120/10 Caspian HL 120/10 4.4 (15000) 5.3 (18100) 5.8 (19800) 3.4 (11700) 4.2 (14200) 4.6 (15600)
Caspian LL 120/11 Caspian HL 120/11 4.8 (16500) 5.8 (19800) 6.2 (21200) 3.8 (13000) 4.6 (15600) 4.9 (16600)
Caspian LL 120/12 Caspian HL 120/12 5.3 (18100) 6.2 (21200) 6.7 (22800) 4.2 (14200) 4.9 (16700) 5.2 (17900)
Model Heat Output at 40ºC Low Medium High Low Level High Level kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Caspian LL 60/03 Caspian HL 60/03 0.9 (3050) 1.0 (3400) 1.1 (3600)
Caspian LL 60/04 Caspian HL 60/04 1.1 (3800) 1.3 (4350) 1.4 (4900)
Caspian LL 90/06 Caspian HL 90/06 1.7 (5900) 1.9 (6600) 2.1 (7100)
Caspian LL 90/07 Caspian HL 90/07 1.9 (6600) 2.2 (7400) 2.4 (8300)
Caspian LL 120/10 Caspian HL 120/10 2.7 (9100) 3.2 (11000) 3.5 (12100)
Caspian LL 120/11 Caspian HL 120/11 2.9 (10000) 3.5 (12100) 3.8 (12900)
Caspian LL 120/12 Caspian HL 120/12 3.2 (11000) 3.8 (12900) 4.1 (13900)
Heat outputs tested in accordance with BS4856 using mean water temperature, 18°C entering air temperature,10°C temperature drop.
Correction factors
Mean Water Temperature °C
EATºC 80 to 40
15 1.10
21 0.93
Temperature Drop °C
20 15 10 5
Factor 0.89 0.95 1.00 1.04
Model Packed Weight Caspian LL 60/03 28KG Caspian LL 60/04 28KG Caspian LL 90/06 37KG Caspian LL 90/07 39KG Caspian LL 120/10 48KG Caspian LL 120/11 48KG Caspian LL 120/12 48KG Caspian HL 60/03 24KG Caspian HL 60/04 24KG Caspian HL 90/06 37KG Caspian HL 90/07 39KG Caspian HL 120/10 46KG Caspian HL 120/11 46KG Caspian HL 120/12 46KG
1.Co
mm
erci
al f
an c
onve
ctor
s1. Commercial fan convectors
22
Caspian High & LowMotorAC onlyFinishCasing: zinc-coated steel 1.2mm Polyester powder-coated: white RAL 9010Available to special order in any colourAvailable with anti-microbial paint or anti-bacterial paintFilterClass G3, 100% polyester, non-washableInstallation• Suitable for two-pipe central heating systems• Mounting brackets supplied for both models (low level models can sit on the floor)• Maximum installation height for high level mounted model - 4m to underside• Pipework access holes on the rear and underside (Low) and top (High)• Key operated front access panels• Bleed valve accessible on removal of front casing• Tamperproof control panel (low level models only)• Unit must be earthedCommissioningCheck water is hot enough to activate the low temperature cut-out thermostatControlsRocker switch - low/medium/high heat outputIlluminated rocker switch - on/offFacility to connect room thermostatLow temperature cut-out thermostat set to energise fan at approximately 35°CAccessoriesWall mounted room thermostatAdjustable low temperature cut-out (30°C to 90°C)Thermostat (T1) & auto speed control (T2) Low only
Model A 60 595 90 895 120 1195
Caspian Low Level
66
Pipe Centres 176
250
245
Electrical supply in this side
A
530
Caspian High Level
All dimensions in mm
www.SmithsEP.co.uk/commercialSee Glossary on page 46 for further information on Accessories
1. Commercial fan convectors1.
Com
mer
cial
fan
con
vect
ors
Adjustable lowtemperaturecut-out
Thermostat and autospeed control
Wall mounted roomthermostat
Tamperproof controlpanel
Caspian High & Low
Accessories
23 www.SmithsEP.co.uk/commercial
1.Co
mm
erci
al f
an c
onve
ctor
s1. Commercial fan convectors
Sterling
Sterling Electric E 3kW
Sterling Electric
Motor
AC only
Finish
Outer casing 0.9mm zinc-coated steel. Polyester powdercoated.
Paint specification: textured white, BS 4800 00A01 18%gloss
Side panels: Polymer - white
Installation
• Recommended installation height 2.3m (7ft 6") to underside
• Not suitable for bathrooms and other high humidity areas
• Angled mounting (optional)
• 13 amp fused spur required
• Unit must be earthed
Controls
Rocker switches for fan and element - fan-only/1kW/2kW/3kW
Built-in room thermostat
Overheat protection: thermal cut-out.
Manual reset procedure: switch power off at mains, wait 20minutes, switch power on.
Heat Output (kW)
Power Consumption (kW)
Fused Mains Sound Casing Fan-Only Model Spur Cable (m) Levels (dBA) Colour
Electric
Sterling E 3kW 1kW/2kW/3kW 1kW/2kW/3kW 13A n/a 39 White •
The Sterling fan-assisted electric heater is a great low cost solution providing effective anddependable heating for both small and large commercial areas, fitted unobtrusively abovehead height. It has been designed for rooms with limited lower wall space, such as shopsand libraries, in mind.
Additional information
Electric fan-assisted heaters cost around 15p per hour for each 1kW of heat.
Hydronic versions available - see page 28
Sound levels measured at 1.5m with the product installed at 2.2m high
All dimensions in mm
Model Packed Weight Sterling E 3kw 4KG
See Glossary on page 46 for further information on Accessories
24 www.SmithsEP.co.uk/commercial
1. Commercial fan convectors1.
Com
mer
cial
fan
con
vect
ors
Caspian Skyline
The latest addition to the Caspian range, Caspian Skyline fits into a 600mm x 600mmceiling tile, providing easy access for both installation and maintenance. It’s suitable forprojects in schools, retail or food units or where the heating needs to complement therest of the premise. Using current EC technology, it delivers discreet heating and plumbseasily into the central heating system.
The Caspian Skyline has been developed to provide a more easily installed ceiling tile fanconvector to complement the Smith’s range of Caspian commercial fan convectors andmay be used alone or in tandem with other Smith’s products. Plumbing easily into anywet central heating system, the Caspian Skyline will also work effectively and efficientlywith renewable heat sources, such as air or ground source heat pumps.
Correction factors
Mean Water Temperature °C
EATºC 80 to 40
15 1.10
21 0.93
Temperature Drop °C
20 15 10 5
Factor 0.89 0.95 1.00 1.04
Heat outputs tested in accordance with BS EN442 using mean water temperature, 18°C entering air temperature, 10°C temperature drop.
Model Heat Output at 80° Heat Output at 75° Heat Output at 70°
Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)
Caspian Skyline CT60 3.1 (10500) 4.1 (14000) 5.1 (17500) 2.7 (9200) 3.7 (12500) 4.6 (15700) 2.3 (8000) 3.2 (11000) 4.1 (14000)
Model Heat Output at 65° Heat Output at 60° Heat Output at 55°
Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)
Caspian Skyline CT60 2.3 (7700) 2.9 (10000) 3.6 (12200) 2.2 (7400) 2.6 (8900) 3.1 (10500) 1.5 (5000) 2.0 (6900) 2.6 (8700)
Model Heat Output at 50° Heat Output at 45° Heat Output at 40°
Low Medium High Low Medium High Low Medium High (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU) (KW/BTU)
Caspian Skyline CT60 0.8 (2600) 1.4 (4800) 2.1 (7000) 0.5 (1700) 0.9 (3000) 1.3 (4400) 0.2 (800) 0.4 (1300) 0.5 (1700)
25 www.SmithsEP.co.uk/commercial
Caspian Skyline
Motor
EC and AC
EC motors are BMS compliant
Finish
Casing: galvanised steel 1.2mm
Grille
Eggcrate core, white RAL 9010 complete with touch catches
Filter
Class G3, 100% polyester, non-washable
Installation
• Suitable for two-pipe central heating systems
• Maximum installation height – 4m to underside
• Unit must be earthed
Commissioning
Check water is hot enough to activate the low temperature cut-outthermostat
Controls
Variable heat output controller (mounted within the product)
Accessories
Adjustable low temperature cut-out (30°C to 90°C)
External control harness (for up to 4 products)
22mm flexible hoses (pair)
All dimensions in mm
Sound levels measured at 3.0m.
Model Total Power Consumption
Flow & Return Mains Flexible Isolation Fused Low Medium High Water CapacityConnections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Watts) (Litres)
Caspian Skyline CT60 22mm n/a n/a n/a n/a 3A 8 24 40 0.75
Model Packed Weight Caspian Skyline CT60 20KG
215 Heater Unit Grille
538
110275
570 Hanging Ctrs
50 5565
45
538
204
595563
595 595
500Hanging
Ctrs
External controlharness
Adjustable lowtemperaturecut-out
22mm flexible hoses
Model Sound Levels
High Medium Low Grille Fan(dBA) (dBA) (dBA) Colour Only
Caspian Skyline CT60 48 40 34 White n/a
See Glossary on page 46 for further information on Accessories
1.Co
mm
erci
al f
an c
onve
ctor
s1. Commercial fan convectors
Sound Levels Normal Boost Model (dBA) (dBA) Casing Colour Fan-Only
Hydronic
Skyline CT18 44 55 White •
Sound levels measured at 1.5m.
26
Skyline®
The Skyline® fits neatly into existing ceiling space - replacing a 600mm x 600mm ceilingtile and because it is ceiling mounted, it saves valuable wall space - particularly importantin retail units. It is unobtrusive and effective. Supplied as standard in white but casing canbe supplied in any colour.
Power Consumption Flow and Return Main Flexible Isolating Fused Normal Boost Water Capacity Model Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres)
Hydronic
Skyline CT18 22mm 1.5m n/a n/a n/a 3A 50 70 0.9
Skyline CT18Motor
AC only
Finish
Outer casing 0.7mm zinc-coated steel. Polyester powder-coated Paint specification: textured white, BS 4800 00A01 18% gloss
Installation
• Maximum installation height 3.2m (10'6") to underside
• Installed to 180mm - penetration depth in recess (excluding fittings)
• Four air inlet options: room only, void only, room and void, fresh air (spigot required)
• 600mm side clearance required
• Fixing brackets (4) supplied for connection to 6mm threaded rods or chains(rods and chains - not supplied)
• Blanking plates (2) supplied for air circulation options
• Unit must be earthed
• Supplied with remote operating switch
• Suitable for two-pipe central heating systems only
Commissioning
Check water temperature is hot enough to activate low temperature cut-out (LTC). The inclusion of an automatic air vent at the highest point isrecommended to avoid possible air locks
Controls
Two rocker fan switches - normal/off/boost, fan-heating/fan-only.
Low temperature cut-out thermostat set to energise fan at approximately 35°C
Accessories
Wall mounted room thermostat
Fresh air inlet spigot to suit 100mm flexible hose
Skyline CT1822
Pipe Centres
28
90
22mmFlow and Return Pipes
90
100
Heat exchangerdrain off valve
Outlet panel fits overceiling tile frame
Air in void or roomdamper at both ends
600
542
516centres
498
cent
res
600555
280
45 cent
res
Fixing points
www.SmithsEP.co.uk/commercial
Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Skyline CT18 3.5 (11900) 5.5 (18800) 3.1 (10700) 5.0 (16900) 2.8 (9600) 4.4 (15000) 2.5 (8700) 3.9 (13200)
Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Skyline CT18 2.3 (7900) 3.3 (11400) 2.1 (7000) 3.0 (10100) 1.8 (6000) 2.6 (8900) 1.5 (5100) 2.2 (7600)
Heat Output at 40ºC Normal Boost Model kW (Btu/h) kW (Btu/h)
Hydronic
Skyline CT18 1.2 (4100) 1.8 (6300)
Heat outputs tested in accordance with BS4856 using entering water temperatureand 340 l/h (75gph) flow rate.
Model Packed Weight Skyline CT18 20KG
See Glossary on page 46 for further information on Accessories
1. Commercial fan convectors1.
Com
mer
cial
fan
con
vect
ors
27 www.SmithsEP.co.uk/commercial
1.Co
mm
erci
al f
an c
onve
ctor
s
Skyline® E 4kW
Multiple positions (14) for suspension points
507
151
15600
600264
248
cent
res
Skyline® E 4kW
Finish
Outer casing 0.9mm zinc-coated steel. Polyester powder-coated Paint specification: textured white, BS 4800 00A01 18% gloss
Installation
• Maximum installation height 3.2m (10'6") to underside
• Minimum 150mm void space required for recessedinstallation
• Not suitable for bathrooms and other high humidity areas
• Two air inlet options: room only, room and void
• Maximum flexibility in installation: only 600mm - sideclearance required
• Facility for connection to 6mm threaded rod or chains (rods and chains - not supplied)
• 20 amp fused spur required
• Unit must be earthed
• Supplied with remote operating switch
Controls
Rocker switches for fan and element
Overheat protection: thermal cut-out. Manual reset procedure:switch power off at mains, wait 5 minutes, switch power on
Accessories
Surface mounting kit - 135mm. Provides a complete four-sided trim when fitted to a solid ceiling
Ceiling tile spacer - 85mm. Provides semi-recessed profile tomatch Skyline CT18 when used in ceiling tile frame
Room thermostats used in conjunction with Skyline E 4kWmust be rated at 20A minimum
The electric Skyline® fits neatly into existing ceiling space - replacing a 600mm x 600mmceiling tile and because it is ceiling mounted, it saves valuable wall space - particularlyimportant in retail units. It is unobtrusive and effective. Like its hydronic cousin, this high-output fan convector effectively heats large areas. Supplied as standard in white but canbe supplied in any colour.
Heat Output (kW) Power Consumption (kW) Fused Mains Sound Casing Fan-Only Model Normal Boost Normal Boost Spur Cable (m) Levels (dBA) Colour Electric
Skyline E 4kW 4.0 4.0 4.1 4.1 20A 1.5 40 White n/a
Skyline®
Additional information
Electric fan-assisted heaters cost around 15p per hour for each 1kW of heat.Hydronic model available.
1. Commercial fan convectors
28 www.SmithsEP.co.uk/commercial
The Ecovector® and Sterling Hydronic and Hydronic Low Voltage fan convectors provideeffective and dependable heating for both small and large commercial areas, fittedunobtrusively above head height. They work particularly well in shops and libraries, wherelower wall space is limited. Supplied as standard in white but casing can be supplied in anycolour.
Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Ecovector HL 1000 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400)
Ecovector HL 2300 2.3 (7850) 3.1 (10500) 2.1 (7000) 2.8 (9400) 1.9 (6400) 2.5 (8500) 1.7 (5700) 2.1 (7300)
Ecovector HL 2900 2.9 (10000) 4.2 (14500) 2.7 (9200) 4.0 (13500) 2.5 (8500) 3.5 (12000) 2.3 (7700) 3.2 (11000)
Ecovector HL 4000 4.0 (13500) 5.3 (18000) 3.7 (12500) 4.8 (16500) 3.3 (11300) 4.4 (15100) 3.0 (10400) 4.1 (13900)
Sterling 1000-240V 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400)
Hydronic Low Voltage
Ecovector HL 1000-12V 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400)
Sterling 1000-12V 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400)
Ecovector®
/Sterling High
Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Ecovector HL 1000 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000)
Ecovector HL 2300 1.4 (4800) 1.9 (6600) 1.4 (4700) 1.8 (6300) 1.2 (4100) 1.6 (5500) 1.1 (3600) 1.4 (4800)
Ecovector HL 2900 2.1 (7200) 2.9 (9800) 1.9 (6600) 2.6 (8900) 1.6 (5400) 2.3 (7800) 1.4 (4750) 2.0 (6800)
Ecovector HL 4000 2.7 (9100) 3.4 (11500) 2.4 (8200) 3.2 (10900) 2.1 (7150) 2.8 (9600) 1.8 (6300) 2.5 (8400)
Sterling 1000-240V 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000)
Hydronic Low Voltage
Ecovector HL 1000-12V 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000)
Sterling 1000-12V 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000)
Heat Output at 40ºC Normal Boost Model kW (Btu/h) kW (Btu/h)
Hydronic
Ecovector HL 1000 0.4 (1350) 0.5 (1800)
Ecovector HL 2300 0.9 (3000) 1.2 (4000)
Ecovector HL 2900 1.2 (4000) 1.7 (5700)
Ecovector HL 4000 1.6 (5300) 2.1 (7000)
Sterling 1000-240V 0.4 (1350) 0.5 (1800)
Hydronic Low Voltage
Ecovector HL 1000-12V 0.4 (1350) 0.5 (1800)
Sterling 1000-12V 0.4 (1350) 0.5 (1800)
Heat outputs tested in accordance with BS4856 using entering water temperatureand 340 l/h (75gph) flow rate.
Sound levels measured at 1.5m.
1. Commercial fan convectors1.
Com
mer
cial
fan
con
vect
ors
Sound Levels Normal Boost Casing Model (dBA) (dBA) Colour Fan-Only
Hydronic
Ecovector HL 1000 32 40 White •
Ecovector HL 2300 34 50 White •
Ecovector HL 2900 37 51 White •
Ecovector HL 4000 39 52 White •
Sterling 1000-240V 32 40 White •
Hydronic Low Voltage
Ecovector HL 1000-12V 32 39 White •
Sterling 1000-12V 32 39 White •
Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Model Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres)
Hydronic
Ecovector HL 1000 15mm 1.5m n/a n/a n/a 3A 20 25 0.28
Ecovector HL 2300 15mm 1.5m n/a n/a n/a 3A 20 32 0.32
Ecovector HL 2900 15mm 1.5m n/a n/a n/a 3A 33 50 0.52
Ecovector HL 4000 22mm 1.5m n/a n/a n/a 3A 40 60 1.04
Sterling 1000-240V 15mm 1.5m n/a n/a n/a 3A 20 25 0.28
Hydronic Low Voltage
Ecovector HL 1000-12V 15mm 0.45m • n/a n/a 3A 20 25 0.28
Sterling 1000-12V 15mm 0.45m • n/a n/a 3A 20 25 0.28
Wall mounted roomthermostat
Sterling Hydronic 1000-240V, 1000-12V
276
Electrical supplyin this side
124
37
96
112
540
5325
80Pipe Centres
29 www.SmithsEP.co.uk/commercial
Ecovector® HL 4000
276
Electrical supplyin this side
124
37
96
112
8825
80Pipe Centres
A
Pipe Centres690
Electrical supplyin this side
124
100
78
35
112276
All dimensions in mm
Model A 1000 470 1000-12V 470 2300 781 2900 1062 4000 1412
Ecovector® HL 1000, 1000-12V, 2300, 2900A
Model Packed Weight Ecovector HL 1000 7KG Ecovector HL 2300 11KG Ecovector HL 2900 15KG Ecovector HL 4000 18KG Sterling 1000-240v 7KG
Ecovector HL 1000-12V 8KG Sterling 1000-12V 8KG
Ecovector®/Sterling High Level
Motor
AC only
Finish
Front casing: zinc-coated steel. Polyester powder-coated: texturedwhite BS 4800 00A01 18% gloss
Side panels: polymer eggshell white
Installation
• Maximum installation height 2.1m (6’11”) to underside
• No top or side clearance required
• Unit must be earthed (except model 1000-12V)
• Suitable for two-pipe central heating systems
• Patress box not supplied for transformer (model 1000-12V)
Commissioning
Check water is hot enough to activate the low temperature cut-outthermostat. The inclusion of an automatic air vent at the highestpoint is recommended to avoid possible air locks
Controls
Two rocker switches - normal/off/boost, heating/fan-only
Low temperature cut out thermostat, set to energise fan atapproximately 35°C
Accessory
Wall mounted room thermostat
See Glossary on page 46 for further information on Accessories
1.Co
mm
erci
al f
an c
onve
ctor
s1. Commercial fan convectors
Summary of product ranges - Domestic applications
30
Sum
mar
y of
pro
duct
ran
ges
- Dom
esti
c ap
plic
atio
ns
Space Saver - HydronicPlinth heaters p42-44
Providing an alternative to the traditional radiator, the Smith’s Space Saver sits neatly inthe plinth at the bottom of your kitchen units to create space for extra cupboards, morework surface and additional appliances. Heat outputs up to 2.4kW (8200 Btu/h).
Hydroflame®
Fan convector p38-40
The Hydroflame® hydronic flame-effect fan convectors provide the visual appeal of a realfire but are safer and more energy efficient and fit on any internal or external wall surface,into a fireplace opening or in front of a fireplace surround, affording the homeowner ahuge degree of flexibility for room design and layout. Heat outputs up to 2.0kW (6800 Btu/h).
Ecovector® Vertical Fan convectors p36Designed for installation in narrowspaces like hallways, and other smallerrooms, this vertical low-level wall-mounted fan convector includeswireless thermostatic control. Heatoutput up to 2.6kW (8800 Btu/h).
Eco-Powerad®
Fan convector p35The fan convector of the future –energy efficient, responsive and capableof installation within most wet centralheating systems driven by either boilersor low temperature renewabletechnology. Heat outputs up to 3.9kW(13200 Btu/h).
SpacemakerFan convector p37
Floor-fitted fan convector, ideal forentrance halls and lobbies where wallspace is limited. Heat outputs up to1.6kW (5500 Btu/h).
Sureline®
Natural convectors p41A natural convector fitted at skirtinglevel - the ideal form of perimeterheating, providing gentle low-levelwarmth anywhere from hallways andconservatories to airing cupboards. Heat outputs up to 820W (2520Btu/h)per metre.
Ecovector®/Sterling High Fan convector p32-33Designed for unobtrusive fixing at highlevel and ideal for a wide range of livingareas. Both hydronic and electricversions available plus a low voltagemodel for bathrooms. Heat outputs upto 4.0 kW (13500 Btu/h).
Ecovector® Low Fan convector p34Combining stylish good looks withenergy efficiency, Ecovector® Lowincludes built-in thermostatic control.Heat outputs up to 3.5kW (12100Btu/h).
Space Saver - ElectricPlinth heaters p45
The Smith’s Space Saver SS80 sits neatlyin plinths just 8cm deep, common inScandinavian-style kitchens to createextra space for more cupboards,worktops, appliances or instead ofunderfloor heating.
www.SmithsEP.co.uk/domestic
31
Sum
mar
y of
pro
duct
ran
ges
- Dom
esti
c ap
plic
atio
ns
www.SmithsEP.co.uk/domestic
Applications chartDomesticRoom Best 444 Better 44 Good 4Kitchen/Utility Room Space Saver Plinth Ecovector® High Ecovector® Low Sterling High Eco-Powerad® Low
Bathroom/En-suite Space Saver Plinth Ecovector® High Sterling HighCloakroom Ecovector® High Sureline® Ecovector® Low Sterling High Eco-Powerad® Low Hall Ecovector® Vertical Ecovector® Low Sureline®
Eco-Powerad® LowLanding Ecovector® Low Ecovector® Vertical Eco-Powerad® Low Living Room/Dining Room Ecovector® Low Ecovector® Vertical Spacemaker Recessed Eco-Powerad® LowFireplace Hydroflame® Conservatory Ecovector® High Ecovector® Vertical Sterling HighBedroom Ecovector® Low Sureline® Ecovector® Vertical Eco-Powerad® LowHome Office/Study Ecovector® High Ecovector® Low Ecovector® Vertical Sterling High Eco-Powerad® Low
CommercialRoom Best 444 Better 44 Good 4Showroom Caspian UV/UVC/FF Skyline® Ceiling High Caspian Low Caspian High Ecovector® Sureline®
Caspian Skyline®
Shop Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Skyline® Sterling High
Entrance Hall/Corridor Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Sureline®
Sterling High Spacemaker Recessed
Reception Ecovector® Low Ecovector® Vertical Ecovector® High Eco-Powerad® Low Sureline® Sterling High Caspian High
Waiting Room Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Low Sterling High
Meeting Room/Hall/Club Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Skyline® Sterling High
Changing Room Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Skyline® Sterling High
Public House Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Vertical Caspian High Ecovector® High Caspian Skyline® Sterling High
Place of Worship Caspian UV/UVC/FF/EXT Ecovector® Low Ecovector® Vertical Caspian High Eco-Powerad® Low Sureline®
Caspian Low
School, Nursery Caspian UV/UVC/FF/EXT Skyline® Ceiling Ecovector® High Caspian LST Caspian High Sterling High Caspian Skyline® Sterling High
Care Home, Hospital Caspian UV/UVC/FF Skyline® Ceiling Ecovector® High Caspian Universal LST Caspian High Sterling High Caspian Skyline® Sterling High Sureline®
Library Caspian UV/UVC/FF Skyline® Ceiling Ecovector® Low Caspian High Ecovector® High Eco-Powerad® Low Caspian Skyline® Sterling High
Sound Levels Normal Boost Casing Model (dBA) (dBA) Colour Fan-Only
Hydronic
Ecovector HL 1000 32 40 White •
Ecovector HL 2300 34 50 White •
Ecovector HL 2900 37 51 White •
Ecovector HL 4000 39 52 White •
Sterling 1000-240V 32 40 White •
Hydronic Low Voltage
Ecovector HL 1000-12V 32 39 White •
Sterling 1000-12V 32 39 White •
32
The Ecovector® and Sterling Hydronic and Hydronic Low Voltage fan convectors provideeffective and dependable heating for both large and small rooms, fitted unobtrusivelyabove head height. They work particularly well in conservatories and areas wherelower wall space is limited. Supplied as standard in white but casing can be supplied inany colour.
Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Ecovector HL 1000 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400)
Ecovector HL 2300 2.3 (7850) 3.1 (10500) 2.1 (7000) 2.8 (9400) 1.9 (6400) 2.5 (8500) 1.7 (5700) 2.1 (7300)
Ecovector HL 2900 2.9 (10000) 4.2 (14500) 2.7 (9200) 4.0 (13500) 2.5 (8500) 3.5 (12000) 2.3 (7700) 3.2 (11000)
Ecovector HL 4000 4.0 (13500) 5.3 (18000) 3.7 (12500) 4.8 (16500) 3.3 (11300) 4.4 (15100) 3.0 (10400) 4.1 (13900)
Sterling 1000-240V 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400)
Hydronic Low Voltage
Ecovector HL 1000-12V 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400)
Sterling 1000-12V 1.0 (3500) 1.3 (4600) 1.0 (3300) 1.2 (4050) 0.9 (3100) 1.1 (3750) 0.8 (2800) 1.0 (3400)
Ecovector®
/Sterling High
2. Domestic fan convectors
Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Ecovector HL 1000 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000)
Ecovector HL 2300 1.4 (4800) 1.9 (6600) 1.4 (4700) 1.8 (6300) 1.2 (4100) 1.6 (5500) 1.1 (3600) 1.4 (4800)
Ecovector HL 2900 2.1 (7200) 2.9 (9800) 1.9 (6600) 2.6 (8900) 1.6 (5400) 2.3 (7800) 1.4 (4750) 2.0 (6800)
Ecovector HL 4000 2.7 (9100) 3.4 (11500) 2.4 (8200) 3.2 (10900) 2.1 (7150) 2.8 (9600) 1.8 (6300) 2.5 (8400)
Sterling 1000-240V 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000)
Hydronic Low Voltage
Ecovector HL 1000-12V 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000)
Sterling 1000-12V 0.7 (2550) 0.9 (3200) 0.6 (2100) 0.8 (2750) 0.5 (1850) 0.7 (2400) 0.5 (1600) 0.6 (2000)
Heat Output at 40ºC Normal Boost Model kW (Btu/h) kW (Btu/h)
Hydronic
Ecovector HL 1000 0.4 (1350) 0.5 (1800)
Ecovector HL 2300 0.9 (3000) 1.2 (4000)
Ecovector HL 2900 1.2 (4000) 1.7 (5700)
Ecovector HL 4000 1.6 (5300) 2.1 (7000)
Sterling 1000-240V 0.4 (1350) 0.5 (1800)
Hydronic Low Voltage
Ecovector HL 1000-12V 0.4 (1350) 0.5 (1800)
Sterling 1000-12V 0.4 (1350) 0.5 (1800)
www.SmithsEP.co.uk/domestic
Room SizeGuide* (m3)
29
66
-
-
29
33
25
25
Room SizeGuide* (m3)
29
66
-
-
29
33
25
25
Room SizeGuide* (m3)
29
66
-
-
29
33
25
25
*Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested inaccordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Fan-only option operational only when central heating system is switched off. Soundlevels measured at 1.5m.
Room SizeGuide* (m3)
29
66
-
-
29
33
25
25
2.D
omes
tic
fan
conv
ecto
rs
33
Ecovector®/Sterling HighFinish
Front casing: zinc-coated steel. Polyester, powder-coated: texturedwhite BS 4800 00A01 18% gloss
Side panels: polymer eggshell white
Installation
• Maximum installation height 2.1m (6’11”) to underside
• No top or side clearance required
• Unit must be earthed (except model 1000-12V)
• Suitable for two-pipe central heating systems
• Pattress box not supplied for transformer (model 1000-12V)
Commissioning
Check water is hot enough to activate the low temperature cut-outthermostat. The inclusion of an automatic air vent at the highestpoint is recommended to avoid possible air locks
Controls
Two rocker switches - normal/off/boost, heating/fan-only
Low temperature cut out thermostat, set to energise fan atapproximately 35°C
Accessory
Wall-mounted room thermostat
Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Model Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres)
Hydronic
Ecovector HL 1000 15mm 1.5m n/a n/a n/a 3A 20 25 0.28
Ecovector HL 2300 15mm 1.5m n/a n/a n/a 3A 20 32 0.32
Ecovector HL 2900 15mm 1.5m n/a n/a n/a 3A 33 50 0.52
Ecovector HL 4000 22mm 1.5m n/a n/a n/a 3A 40 60 1.04
Sterling 1000-240V 15mm 1.5m n/a n/a n/a 3A 20 25 0.28
Hydronic Low Voltage
Ecovector HL 1000-12V 15mm 0.45m • n/a n/a 3A 20 25 0.28
Sterling 1000-12V 15mm 0.45m • n/a n/a 3A 20 25 0.28
Ecovector® HL 1000, 1000-12V, 2300, 2900 Ecovector® HL 4000
276
Electrical supplyin this side
124
37
96
112
A
8825
80Pipe Centres
A
Pipe Centres690
Electrical supplyin this side
124
100
78
35
112276
Model A 1000 470 1000-12V 470 2300 781 2900 1062 4000 1412
www.SmithsEP.co.uk/domestic
2. Domestic fan convectors
Sterling Hydronic 1000-240V, 1000-12V
276
Electrical supplyin this side
124
37
96
112
540
5325
80Pipe Centres
All dimensions in mm
All dimensions in mm
2.D
omes
tic
fan
conv
ecto
rs
See Glossary on page 46 for further information on Accessories
2. Domestic fan convectors2.
Dom
esti
c fa
n co
nvec
tors
34
Ecovector®
LowEcovector® Low Level fan convectors provide warmth from the floor upwards and aremore energy efficient and effective than radiators. The Ecovector® can heat up a roommore quickly than radiators, thereby reducing the amount of time your boiler or heatpump is running - making it extremely efficient and cost effective. Ideal for new andexisting developments, due to ease of installation, the Ecovector® is available in a range ofmodels to suit varying room sizes and heat output requirements. Supplied as standard inwhite but casing can be supplied in any colour.
Total Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Model Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres)
Hydronic
Ecovector LL 1200 15mm 1.5m n/a n/a n/a 3A 17 21 0.29
Ecovector LL 2000 15mm 1.5m n/a n/a n/a 3A 26 55 0.58
Ecovector LL 2800 15mm 1.5m n/a n/a n/a 3A 43 76 0.83
Ecovector® Low LevelFinish
Front casing: zinc coated steel. Polyester, powder-coated:textured white BS 4800 00A01 18% gloss
Side panels: polymer eggshell white
Installation
• Mounting bracket supplied
• Unit must be earthed
• Suitable for two-pipe central heating systems
• Minimum height above floor level 150mm
• Maximum height above floor level 500mm
Commissioning
Check water is hot enough to activate the selectable lowtemperature cut-out thermostat
Controls
Rocker switch - normal/off/boost
Built-in room thermostat
Low temperature cut-out thermostat set to energise fan atapproximately 35°C
Electrical supplyin this sidePipe centres
A 115
6833
36
98
37
Ø15445
150
All dimensions in mm
Model A LL 1200 635 LL 2000 1025 LL 2800 1385
Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Ecovector LL 1200 0.8 (2600) 1.0 (3450) 0.7 (2250) 0.8 (2900) 0.6 (1900) 0.7 (2500) 0.5 (1600) 0.6 (2050)
Ecovector LL 2000 1.3 (4550) 1.7 (5900) 1.2 (4050) 1.6 (5300) 1.0 (3500) 1.3 (4400) 0.9 (3050) 1.1 (3700)
Ecovector LL 2800 1.9 (6400) 2.4 (8100) 1.5 (5200) 2.1 (7200) 1.3 (4500) 1.8 (6100) 1.2 (4000) 1.5 (5200)
Heat Output at 40ºC Normal Boost Model kW (Btu/h) kW (Btu/h)
Hydronic
Ecovector LL 1200 0.4 (1250) 0.5 (1600)
Ecovector LL 2000 0.7 (2500) 0.8 (2900)
Ecovector LL 2800 1.0 (3250) 1.2 (4200)
www.SmithsEP.co.uk/domestic
Room SizeGuide* (m3)
34
57
80
Room SizeGuide* (m3)
34
57
80
Room SizeGuide* (m3)
34
57
80
Room SizeGuide* (m3)
34
57
80
*Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested in accordancewith BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Sound levels measured at 1.5m.
See Glossary on page 46 for further information on Accessories
Sound Levels Normal Boost Casing Model (dBA) (dBA) Colour Fan-Only
Hydronic
Ecovector LL 1200 32 38 White n/a
Ecovector LL 2000 35 40 White n/a
Ecovector LL 2800 37 42 White n/a
Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Ecovector LL 1200 1.2 (4000) 1.6 (5400) 1.1 (3700) 1.4 (4800) 1.0 (3350) 1.3 (4300) 0.9 (3000) 1.1 (3900)
Ecovector LL 2000 2.0 (6900) 2.6 (8900) 1.9 (6400) 2.4 (8200) 1.6 (5500) 2.2 (7600) 1.5 (5000) 1.9 (6600)
Ecovector LL 2800 2.8 (9700) 3.5 (12100) 2.6 (9000) 3.2 (11050) 2.3 (8000) 2.9 (10000) 2.0 (6800) 2.6 (9000)
35 www.SmithsEP.co.uk/domestic
2. Domestic fan convectors
2.D
omes
tic
fan
conv
ecto
rs
Eco-Powerad®
The Eco-Powerad® is the fan convector of the future - energy efficient, responsive andsuitable for installation within most wet central heating systems, driven by either boilers orlow temperature renewable technology. Compact, with smooth lines to achieve visualsimplicity, the Eco-Powerad® also features low surface temperature casing for completesafety and possesses a very low operating sound - between 28 and 32 decibels. Suppliedas standard in white but can be supplied in any colour.
Model A Eco-Powerad 500 485 Eco-Powerad 1000 845 Eco-Powerad 1500 1210 Eco-Powerad 2000 1570
Eco-Powerad®
Finish
Front casing: zinc coated steel Polyester, powder-coated: white RAL 9010
Installation
• Mounting bracket supplied
• Unit must be earthed
• Suitable for two-pipe central heating systems
• Minimum height above floor level 150mm
• Maximum height above floor level 500mm
Commissioning
Check water is hot enough to activate the low temperature cut-out thermostat. Ensure system is balanced for evenheat distribution
Controls
Low temperature cut-out thermostat, set to energise fan atapproximately 35°C
Suitable for thermostatic radiator valves (TRV) - not supplied
Rocker switch - normal/low
Accessory
Wall-mounted room thermostat.
A
All dimensions in mm
26 26
400332
95
150 minElectrical supplyin this side
38
Model Sound Casing Flow & Mains Flexible Isolating Fused Total Power Water Levels* Colour Return Cable Transformer Hoses Valves Spur Consumption Capacity (dBA) Connections (Watts) (Litres)
Hydronic
Eco-Powerad 500 28 White 15mm 2m n/a n/a n/a 3A 15 0.17
Eco-Powerad 1000 30 White 15mm 2m n/a n/a n/a 3A 18 0.28
Eco-Powerad 1500 31 White 15mm 2m n/a n/a n/a 3A 33 0.44
Eco-Powerad 2000 32 White 15mm 2m n/a n/a n/a 3A 36 0.55
*Measured at 1.5m.
Heat Heat Heat Heat Heat Heat Heat Heat Heat Output Output Output Output Output Output Output Output Output
at 80ºC at 75ºC at 70ºC at 65ºC at 60ºC at 55ºC at 50ºC at 45ºC at 40ºCModel kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Eco-Powerad 500 0.9 (3100) 0.8 (2900) 0.8 (2750) 0.7 (2400) 0.6 (2050) 0.5 (1875) 0.5 (1700) 0.4 (1375) 0.3 (1050)
Eco-Powerad 1000 2.4 (8200) 2.1 (7150) 1.8 (6100) 1.6 (5450) 1.4 (4775) 1.2 (4100) 1.0 (3400) 0.8 (2725) 0.7 (2400)
Eco-Powerad 1500 2.6 (8900 2.4 (8200) 2.2 (7500) 2.0 (6825) 1.9 (6475) 1.7 (5800) 1.5 (5100) 1.2 (4100) 0.9 (3100)
Eco-Powerad 2000 3.9 (13200) 3.5 (11950) 3.2 (10900) 2.8 (9550) 2.5 (8525) 2.2 (7675) 2.0 (6800) 1.7 (5800) 1.3 (4600)
Wall-mounted room thermostat
Room SizeGuide* (m3)
14
29
43
57
*Room sizes given in cubic metres for general guidance only based on normal heat output (50ºC) for domestic applications - always calculate heat losses. Heat outputs tested inaccordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate.
At inlet water temperatures of 75°C and below, all Eco-Powerad models are classified as LST (low surface temperature) appliances.
See Glossary on page 46 for further information on Accessories
36
Ecovector®
VerticalEcovector® Vertical is ideal for hallways, alcoves and other places where space is limited.Ecovector® can heat up a room more quickly than radiators, thereby reducing the amountof time your boiler or heat pump is running - making it extremely efficient and costeffective. Ideal for new and existing housing developments, due to ease of installation.Supplied as standard in white but can be supplied in any colour.
Ecovector® Vertical
Finish
Front casing and side panels: zinc-coated steel. Polyester,powder-coated: textured white BS 4800 00A01 18% gloss
Installation
• Mounting bracket supplied
• Unit must be earthed
• Suitable for two-pipe central heating systems
• Minimum height above floor level 150mm, maximumheight above floor level 500mm
Commissioning
Check water is hot enough to activate the selectable lowtemperature cut-out thermostat
Controls
Rocker switch - normal/off/boost
Low temperature cut-out thermostat set to energise fan atapproximately 35°C
Wireless wall mounted thermostat included with this product All dimensions in mm
Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Model Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres)
Hydronic
Ecovector® VE 2500 15mm 1.5m n/a n/a n/a 3A 28 36 0.75
Sound Levels Normal Boost Casing Model (dBA) (dBA) Colour Fan-Only
Hydronic
Ecovector VE 2500 36 39 White n/a
Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Ecovector VE 2500 2.5 (8500) 2.6 (8800) 2.3 (7800) 2.4 (8200) 2.0 (6900) 2.1 (7300) 1.9 (6400) 2.0 (6700)
Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Ecovector VE 2500 1.7 (5800) 1.8 (6000) 1.5 (5100) 1.5 (5200) 1.3 (4400) 1.3 (4600) 1.1 (3800) 1.1 (3900)
Heat Output at 40ºC Normal Boost Model kW (Btu/h) kW (Btu/h)
Hydronic
Ecovector VE 2500 0.9 (3200) 1.0 (3400)
*Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested inaccordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Fan-only option operational only when central heating system is switched off.
www.SmithsEP.co.uk/domestic
Room SizeGuide* (m3)
71
Room SizeGuide* (m3)
71
Room SizeGuide* (m3)
71
Room SizeGuide* (m3)
71
330160
770
100 Min28
5438
22
16
Electrical Supplyin this side
PipeCtrs
See Glossary on page 46 for further information on Accessories
2. Domestic fan convectors2.
Dom
esti
c fa
n co
nvec
tors
37 www.SmithsEP.co.uk/domestic
2. Domestic fan convectors
2.D
omes
tic
fan
conv
ecto
rs
SpacemakerPerfect for places in the home where space is particularly limited. A fan convector thatinstalls flush with the floor, providing efficient and effective heat at low level. Ideal forspaces such as entrance halls, lobbies, circulation areas and applications where wall spaceis limited.
Spacemaker SST8
Finish
Anodised aluminium grille with removable centre section.
Installation
• Installs between floor joists or purpose made trenches inconcrete floors
• Air intake and discharge through grille
• Unit must be earthed
• Suitable for two-pipe central heating systems only
Commissioning
Check water temperature is hot enough to activate lowtemperature cut-out (LTC). Vent screw accessible throughgrille
Controls
Rocker switch - normal/off/boost, below grille
Low temperature cut-out thermostat set to energise fan atapprox. 35°C
Accessories
Wall-mounted room thermostat
194
397
298
236
35020
161
Air flow pattern
Floor cut out size:357 x 254
35Pipe
Centres
Spacemaker SST8
All dimensions in mm
Wall-mounted room thermostat
Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Spacemaker SST8 1.6 (5500) 2.2 (7500) 1.5 (5000) 2.1 (7100) 1.3 (4400) 1.8 (6100) 1.2 (4100) 1.7 (5800)
Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Model Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres)
Hydronic
Spacemaker SST8 15mm 1.5m n/a n/a n/a 3A 20 30 0.27
Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Spacemaker SST8 1.1 (3700) 1.5 (5100) 0.9 (3200) 1.3 (4500) 0.8 (2800) 1.2 (4000) 0.7 (2400) 1.0 (3400)
Sound Levels Normal Boost Model (dBA) (dBA) Casing Colour Fan-Only
Hydronic
Spacemaker SST8 32 39 Anodised n/a aluminium grille
Heat Output at 40ºC Normal Boost Model kW (Btu/h) kW (Btu/h)
Hydronic
Spacemaker SST8 0.6 (1900) 0.9 (3000)
Room SizeGuide* (m3)
46
Room SizeGuide* (m3)
46
Room SizeGuide* (m3)
46
*Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested inaccordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Sound levels measured at 1.5m.
Room SizeGuide* (m3)
46
See Glossary on page 46 for further information on Accessories
Hydroflame®
Flame-effect fan convectors that run off the central heating system, but with all the visualappeal of a real fire – a beautiful feature in any room. Efficient, cost effective and totallysafe, with no harmful discharges. Ideal for children and the elderly because there are noflames or hot surfaces. Available in Inset or Freestanding and a choice of eyecatchingdesigns. Hydroflame Classic and Elite can be supplied with an attractive choice of trimsand complementary fireplace surrounds.
38 www.SmithsEP.co.uk/domestic
Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Inset (Classic & Elite) 1.5 (5100) 2.0 (6800) 1.3 (4600) 1.8 (6200) 1.2 (4100) 1.6 (5500) 1.1 (3700) 1.5 (5100)
Freestanding (Classic & Elite) 1.5 (5100) 2.0 (6800) 1.3 (4600) 1.8 (6200) 1.2 (4100) 1.6 (5500) 1.1 (3700) 1.5 (5100)
Hydronic/Electronic (Dual)
Inset Dual (Classic & Elite) 1.5 (5100) 2.0 (6800) 1.3 (4600) 1.8 (6200) 1.2 (4100) 1.6 (5500) 1.1 (3700) 1.5 (5100) 1.5 - 1.5 - 1.5 -
Freestanding Dual (Classic & Elite) 1.5 (5100) 2.0 (6800) 1.3 (4600) 1.8 (6200) 1.2 (4100) 1.6 (5500) 1.1 (3700) 1.5 (5100) 1.5 - 1.5 - 1.5 - 1.5 -
In hydronic mode In electric mode
Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
Inset (Classic & Elite) 0.9 (3200) 1.3 (4500) 0.8 (2600) 1.1 (3900) 0.7 (2300) 1.0 (3500) 0.6 (2000) 0.9 (3000))
Freestanding (Classic & Elite) 0.9 (3200) 1.3 (4500) 0.8 (2600) 1.1 (3900) 0.7 (2300) 1.0 (3500) 0.6 (2000) 0.9 (3000)
Hydronic/Electronic (Dual)
Inset Dual (Classic & Elite) 0.9 (3200) 1.3 (4500) 0.8 (2600) 1.1 (3900) 0.7 (2300) 1.0 (3500) 0.6 (2000) 0.9 (3000) 1.5 - 1.5 - 1.5 -
Freestanding Dual (Classic & Elite) 0.9 (3200) 1.3 (4500) 0.8 (2600) 1.1 (3900) 0.7 (2300) 1.0 (3500) 0.6 (2000) 0.9 (3000) 1.5 - 1.5 - 1.5 - 1.5 -
Heat Output at 40ºC Normal Boost Model kW (Btu/h) kW (Btu/h)
Hydronic
Inset (Classic & Elite) 0.5 (1700) 0.8 (2600)
Freestanding (Classic & Elite) 0.5 (1700) 0.8 (2600)
Hydronic/Electronic (Dual)
Inset Dual (Classic & Elite) 0.5 (1700) 0.8 (2600) 1.5 -
Freestanding Dual (Classic & Elite) 0.5 (1700) 0.8 (2600) 1.5 -
Sound Levels Normal Boost Flame-Effect Model (dBA) (dBA) Trim Colour Only
Hydronic
Inset (Classic & Elite) 27 43 Brass or Chrome •
Freestanding (Classic & Elite) 27 43 Brass or Chrome •
Hydronic/Electronic (Dual) Inset Dual (Classic & Elite) 27 43 Brass or Chrome • Freestanding Dual (Classic & Elite) 27 43 Brass or Chrome •
Room SizeGuide* (m3)
43
43
29
43
43
Room SizeGuide* (m3)
43
43
29
43
43
Room SizeGuide* (m3)
43
43
29
43
43
*Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested inaccordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Fan-only option operational only when central heating system is switched off. Dualmodels include an electric element which in electric heating mode will emit 1.5kW of heat. Sound levels measured at 1.5m.
Room SizeGuide* (m3)
43
43
29
4343
3. Flame-effect fan convectors3.
Flam
e-ef
fect
fan
con
vect
ors
39 www.SmithsEP.co.uk/domestic
Hydroflame® design options
Model Type Trim Colour
Brass Chrome
Hydroflame Elite
Inset • •
Inset Dual • •
Freestanding • •
Freestanding Dual • •
Hydroflame Classic
Inset • •
Inset Dual • •
Freestanding • •
Freestanding Dual • •
Hydroflame® Classic & EliteConnects to and runs from your central heating system(hydronic mode)Installation• Inset model designed for a recess 400mm x 550mm high
• Unit must be earthed
• Suitable for two-pipe central heating systems only
• Surface temperature of the casing complies with thesafety requirement DHSS DN4
CommissioningCheck water temperature is hot enough to activate lowtemperature cut-out device (LTC) ControlsTwo rocker switches - normal/off/boost, flame-effecton/flame-effect off
Variable low temperature cut-out device factory set toenergise fan at approximately 40°C. Set temperature can beadjusted higher or lower during installation
Built-in room thermostat
Hydroflame® Dual Classic & EliteConnects to and runs from your central heating system (hydronic mode), but also includes anelectric heating element for use when the central heating is switched offInstallation• Inset Dual model designed for a recess 400mm x 550mm high
• Unit must be earthed
• Suitable for two-pipe central heating systems only
• Surface temperature of the casing complies with the safety requirement DHSS DN4CommissioningCheck water temperature is hot enough to activate low temperature cut-out device (LTC)ControlsThree rocker switches - normal/off/boost, hydronic/electric, flame-effect on/flame-effect off
Variable low temperature cut-out device factory set to energise fan at approximately 40°C Set temperature can be adjusted higher or lower during installation
Built-in room thermostat
Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Model Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres)
Hydronic
Inset (Classic & Elite) 15mm 2.0m n/a • • 3A 29 36 0.36
Freestanding (Classic & Elite) 15mm 2.0m n/a • • 3A 29 36 0.36
Hydronic/Electric (Dual)
Inset Dual (Classic & Elite) 15mm 2.0m n/a • • 10A 29 36 0.36 1518 1518
Freestanding Dual (Classic & Elite) 15mm 2.0m n/a • • 10A 29 36 0.36 1518 1518
In hydronic mode In electric mode
Inset & Inset Dual
35
15
12
45
310
210
460
355160
545580
160Pipes Ø15
Freestanding & Freestanding Dual
50
12
45
310
255
650
35
85 568
Pipes Ø15
1009
225
1190 300
715
1220 410
44
Fireplace Surround
All dimensions in mm
Freestanding Classic Chrome Freestanding Classic Brass Freestanding Elite Brass Freestanding Elite Chrome
Cream with cream back plate and hearth
Yew with black back plate and hearth
Yew with cream back plate and hearth
Antique Oak with black back plate and oak hearth
Antique Oak with cream back plate and oak hearth
3.Fl
ame-
effe
ct f
an c
onve
ctor
s
3. Flame-effect fan convectors
40 www.SmithsEP.co.uk/domestic
Features & benefitsCompletely safeHydroflame is safe because it uses water from thecentral heating system to produce heat.
• No independent gas supply needed
• No flue gases are produced – so a flue and COdetector are not required
• No live flames, hot coals or elements
• Low surface temperatures
• No special ventilation required
• Hidden fixings for extra security
• No minimum room size
A beautiful focal feature in the room Stylish and attractive appearance characterisesHydroflame’s innovative design.
• Fit on any internal or external wall surface, intoa fireplace opening, or in front of a fireplacesurround
• Can be used simply to replace an existingpanel radiator
• Can show a comforting flame-effect with orwithout the heating being switched on
Simple controlsOperating Hydroflame could not be simpler.
• Clearly labelled, easy action rocker switches
• Easy to use by elderly or infirm people
Minimal running costsHydroflame has a unique method of operationthat brings significant savings on running costs.
• Operates as part of the central heating system,where average usage on normal heat outputwill add less than £10.00 a year to annualheating bills (excluding any separate use of theelectric heating element on Dual models). Seetable of running costs.
Environmentally friendly
Hydroflame has less of an impact on theenvironment than electric, gas or open firealternatives.
• No harmful gases expelled to the atmosphere
• Automatic response to water temperature,providing the correct amount of heat whenneeded
• Thermostatically controlled
• Slower fan speed for flame-effect only reducesenergy consumption
• Energy saving light bulb
Easy to installHydroflame is economical and straightforward toinstall
• No gas supply or flue required – fix to any wall,internal and external
• No chimney or flue liners required
• Inset models fit standard fireplace openings –no need for a replacement surround
• Flexible hoses, isolation valves and pre-wiredelectric cable supplied as standard
• Connects to standard central heating pipe work
For full installation instructions refer to theHydroflame Installation & User Guide, which isavailable on request; or download it fromwww.smiths-env.com
Low maintenanceCost effective and convenient.
• No need for annual servicing or safety checks –so no access to the property is required
• Easy to change the lamp
• Easy for homeowner to clean the filter system
Very low water contentEach Hydroflame has a very low water content of0.36 litres, around 5% of the water content of anequivalent output steel panel radiator.
Heat exchanger
Lamp
Flame-effect
Plumbedinto centralheatingsystem
Coals
Cool air
Warm air
How Hydroflame® works
Hot water from the central heating system passes through aheat exchanger and transfers its heat to the aluminium fins.
Cooler air is drawn in at floor level and used to create theflame-effect. The air is heated as it passes over the heatexchanger, a patented process that creates a realistic flame-effect, and then expelled gently back into the room.
This gives a more even temperature and will heat a room inmuch less time than a traditional panel radiator.
The fan will not come into operation until the central heatingsystem water passing through the heat exchanger reaches 40°C(or the temperature set by the installer). This ensures that coolerair is not circulated at start up and allows Hydroflame to switchon and off automatically in conjunction with the central heatingsystem.
Flame-effect fan convectors are energy efficient and in thehome will add less than £10.00* to your annual heating bill.
Dual models include an electric heating element – ideal in springand summer when you may need a quick warm up but thecentral heating system is switched off.
Note: *based on electricity charged at 15p/kWh.
AssumptionsElectricity charged at 15p per kWh.Hydroflame operating on normal - 1.5kW heat output.Excludes use of electric heating element.
Annual Running Costs Usage (£) (Hours) 11W Bulb 29W Fan Annual Total
1100 1.82 4.79 6.60
1300 2.15 5.65 7.80
1700 2.81 7.39 10.20
2500 4.13 10.87 15.00
Hydroflame® running costs(Models fitted with 11W energy-saving long-life bulb)
3.Fl
ame-
effe
ct f
an c
onve
ctor
s
41 www.SmithsEP.co.uk/domestic
4. Natural Convectors (perimeter heating)
Sureline®
The Sureline® provides gentle, discreet and efficient low-level warmth and is the idealheating solution for areas where wall space is limited - rooms such as loft conversions andnew-build. Simple to install along the skirting in any room, Sureline® is an efficient naturalconvector that provides discreet heating. Supplied as standard in white but casing can besupplied in any colour.
Sureline®
Finish
Outer casing 0.7mm zinc coated steel. Polyester, powder-coated. Paint specification: textured white BS 4800 00A0118% gloss. Each length includes casing, element, backplateand joining strip. Casing only includes casing, backplate andjoining strip
Installation
• Minimum clearance above floor 50mm
• Flow and return connections 22mm copper
• Designed for system pressures up to 10 bar
• Suitable for two-pipe central heating systems only
Attachments
Casing only (1000mm)
LH valve box/end cap kit RH valve box/end cap kit
Centre valve cover 90° internal cover
90° external cover 135° internal cover
135° external cover Finger guard 500 (500mm)
Finger guard 1000 (1000mm) Element (1000mm)
Customised requirements
We are able to offer casings painted in any colour. Price andavailability will be confirmed at the time of order
*We recommended the use of finger guards in installationswhere infants have access to the underside of Sureline.
17
Length A
Lengthincludes casing,
element,backplate
and joiningstrip
1738
Backplate
17968
31
74.5
Frontcasing
Element
76 75
180
152172
180
75
Centre valve cover
Joining strip
25mm overlapon coverMinimum
overlap20mm
LH and RH valvebox/end
stop kit (RHshown)
Body with openbottom75
180
126.5
128.5
180 180
74
180
75.5
51
51 75.5
500 or 1000
Plan view Plan view Plan view
90° External corner
Finger guard
90° Internal corner 135° External corner135° Internal corner
Plan view
75.5 125
75.5 125
75.5
81.5
75.5
81.5
75.5
92.5
75.5
60.5
92.5
All dimensions in mm
180
Heat OutputFlow Rate Btu/h/m @ average water temperature W/m @ average water temperatureL/h (G/h) 50°C 55°C 60°C 65°C 70°C 75°C 80°C 50°C 55°C 60°C 65°C 70°C 75°C 80°C
Two supplies - Parallel 920 (200) 1310 1570 1820 2070 2300 2560 2810 380 460 530 610 670 750 820
Bottom supply - Top return 920 (200) 1030 1250 1460 1710 1920 2140 2330 300 370 430 500 560 630 680
All heat outputs relate to 1 metre length
Model Length A (mm)
Sureline 2000 2000 Sureline 1500 1500 Sureline 1000 1000 Sureline 1000C* 1000 Sureline 500 500* casing only
Heating element
Sureline with TRV
See Glossary on page 46 for further information on Accessories
4.N
atur
al C
onve
ctor
s (p
erim
eter
hea
ting)
42 www.SmithsEP.co.uk/domestic
5. Plinth Heaters - Hydronic
Space SaverA highly energy efficient fan convector that fits neatly into the plinth of a kitchen unit.Space Saver eliminates the need for conventional radiators. And, as its name implies, thisbrings considerable space saving benefits - more room for extra storage units, more worksurfaces, more space for kitchen appliances.
Space Saver is used predominantly for domestic applications where the ingenious plinth-mounting feature makes it ideal for heating kitchens and utility rooms. Plinth mounting alsomakes Space Saver ideal for certain non-domestic applications such as reception areas,changing rooms, libraries, etc.
*Room sizes given in cubic metres for general guidance only based on normal heat output (80ºC) for domestic applications - always calculate heat losses. Heat outputs tested inaccordance with BS4856 using entering water temperature and 340 l/h (75gph) flow rate. Fan-only option operational only when central heating system is switched off. Dualmodels include an electric element which in electric heating mode will emit 1kW of heat.
Before After
Heat Output at 80ºC Heat Output at 75ºC Heat Output at 70ºC Heat Output at 65ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
SS80 0.8 (2900) 1.1 (3600) 0.8 (2700) 0.9 (3200) 0.7 (2500) 0.8 (2800) 0.6 (2200) 0.7 (2500)
SS3 (Improved heat output) 1.1 (3800) 1.4 (4800) 1.0 (3400) 1.3 (4400) 0.9 (3100) 1.2 (4100) 0.8 (2700) 1.1 (3800)
SS5 1.3 (4400) 1.7 (5800) 1.2 (4100) 1.6 (5500) 1.1 (3800) 1.4 (4700) 1.0 (3400) 1.3 (4400)
SS7 1.6 (5500) 1.9 (6500) 1.4 (4800) 1.8 (6100) 1.3 (4400) 1.6 (5500) 1.2 (4100) 1.5 (5000)
SS9 2.2 (7500) 2.4 (8200) 2.1 (7000) 2.2 (7500) 1.8 (6300) 2.0 (6900) 1.7 (5900) 1.8 (6300)
Hydronic Low Voltage
SS5 12V 1.3 (4400) 1.7 (5800) 1.2 (4100) 1.6 (5500) 1.1 (3800 1.4 (4700) 1.0 (3400) 1.3 (4400)
Hydronic/Electric (Dual)
SS5 Dual 1.3 (4400) 1.7 (5800) 1.2 (4100) 1.6 (5500) 1.1 (3800 1.4 (4700) 1.0 (3400) 1.3 (4400)
1.0 – 1.0 – 1.0 – 1.0 –
Heat Output at 60ºC Heat Output at 55ºC Heat Output at 50ºC Heat Output at 45ºC Normal Boost Normal Boost Normal Boost Normal Boost Model kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h) kW (Btu/h)
Hydronic
SS80 0.6 (1900) 0.7 (2300) 0.5 (1700) 0.6 (2000) 0.4 (1400) 0.5 (1700) 0.35 (1200) 0.4 (1400)
SS3 (Improved heat output) 0.7 (2400) 1.0 (3400) 0.6 (2000) 0.9 (3100) 0.5 (1700) 0.8 (2700) 0.4 (1400) 0.7 (2400)
SS5 0.9 (3100) 1.1 (3800) 0.8 (2700) 1.0 (3400) 0.7 (2400) 0.9 (3100) 0.6 (2000) 0.8 (2700)
SS7 1.1 (3800) 1.3 (4500 1.0 (3400) 1.2 (4000) 0.9 (3100) 1.0 (3400) 0.8 (2700) 0.9 (3000)
SS9 1.5 (5200) 1.7 (5700) 1.3 (4500) 1.5 (5000 1.1 (3900) 1.3 (4300) 0.9 (3200) 1.1 (3700)
Hydronic Low Voltage
SS5 12V 0.9 (3100 1.1 (3800) 0.8 (2700) 1.0 (3400) 0.7 (2400) 0.9 (3100) 0.6 (2000) 0.8 (2700)
Hydronic/Electric (Dual)
SS5 Dual 0.9 (3100 1.1 (3800) 0.8 (2700) 1.0 (3400) 0.7 (2400) 0.9 (3100) 0.6 (2000) 0.8 (2700)
1.0 – 1.0 – 1.0 – 1.0 –
Room SizeGuide* (m3)
24
31
37
46
63
33
37
29
Room SizeGuide* (m3)
24
31
37
46
63
33
37
29
In hydronic mode In electric mode
5.Pl
inth
Hea
ters
- H
ydro
nic
43 www.SmithsEP.co.uk/domestic
In hydronic mode In electric mode
*Room sizes given in cubic metres for general guidance only based on normalheat output (80ºC) for domestic applications - always calculate heat losses. Heatoutputs tested in accordance with BS4856 using entering water temperatureand 340 l/h (75gph) flow rate. Fan-only option operational only when centralheating system is switched off. Dual models include an electric element which inelectric heating mode will emit 1kW of heat.
Heat Output at 40ºC Normal Boost Model kW (Btu/h) kW (Btu/h)
Hydronic
SS80 0.3 (900) 0.3 (1100)
SS3 (Improved heat output) 0.3 (1000) 0.6 (2000)
SS5 0.5 (1700) 0.7 (2400)
SS7 0.6 (2000) 0.8 (2700)
SS9 0.7 (2500) 0.9 (3000)
Hydronic Low Voltage
SS5 12V 0.5 (1700) 0.7 (2400)
Hydronic/Electric (Dual)
SS5 Dual 0.5 (1700) 0.7 (2400)
1.0 –
Power Consumption Flow & Return Mains Flexible Isolating Fused Normal Boost Water Capacity Model Connections Cable Transformer Hoses Valves Spur (Watts) (Watts) (Litres)
Hydronic
SS80 15mm 2.0m n/a • n/a 3A 5 10 0.35
SS3 15mm 2.0m n/a n/a n/a 3A 18 25 0.36
SS5 15mm 2.0m n/a • n/a 3A 18 25 0.36
SS7 15mm 2.0m n/a • n/a 3A 21 30 0.38
SS9 15mm 2.0m n/a • n/a 3A 24 35 0.43
Hydronic Low Voltage
SS5 12V 15mm 0.45m • • n/a 3A 21 30 0.36
Hydronic/Electric (Dual)
SS5 Dual 15mm 2.0m n/a • n/a 5A 18 25 0.36
1009 1013 n/a
In hydronic mode In electric mode
Sound Levels Normal Boost Fascia Grille Model (dBA) (dBA) Finish Fan-Only
Hydronic
SS80 32 40 Stainless Steel •
SS3 26 39 Stainless Steel •
SS5 27 43 Stainless Steel •
SS7 30 44 Stainless Steel •
SS9 41 46 Stainless Steel •
Hydronic Low Voltage
SS5 12V 31 39 Stainless Steel • Hydronic/Electric (Dual)
SS5 Dual 27 43 Stainless Steel •
Sound levels measured at 1.5m.
Room SizeGuide* (m3)
24
31
37
46
63
33
37
29
Room SizeGuide* (m3)
24
31
37
46
63
33
37
5.Pl
inth
Hea
ters
- H
ydro
nic
44 www.SmithsEP.co.uk/domestic
Space Saver
Fascia Grille Finish
Stainles Steel
InstallationImportant: Correct fascia grille opening must be cut to
allow sufficient air intake • 20mm clearance above unit required • Model secured to plinth by two screws
through fascia grille • Unit must be earthed (not 12 volt SELV) • Suitable for two-pipe central heating
systems only • SS80 supplied with detachable cable • SS80 models have easy fit thermostat facilityAccessories
Wall-mounted room thermostat
SS80: Grilles: brown - RAL 8016, black - RAL 9005, white - RAL9010
All other models: Grilles: brown - RAL 8016, black - RAL 9005,white - RAL 9010, chrome, aluminium, gold
Wall mounted control switch (white) to suit SS3, SS5, SS5/12V,SS7, SS9
Commissioning
Check water temperature is hot enough to activate lowtemperature cut-out thermostat (LTC). Vent screw accessiblethrough fascia grille
Controls
Single rocker switch - low/off/normal
SS80: Low temperature cut-out thermostat set to energise fan atapproximately 35°C
SS5 W/Dual: three rocker switches, heating/off/fan-only,hydronic/electric, normal/boost
Low temperature cut-out thermostat set to energise fan atapproximately 35°C
All other models: two rocker switches -normal/off/boost,heating/fan-only
Low temperature cut-out thermostat set to energise fan atapproximately 35°C
62 Pipe centres
SS9
Smiths
30405
98
91
353
14
170225
600
575
9
100
Smiths
20322 91
89
288
120
14
150
498
475
9
100
65 Pipe centres
Wall-mounted room thermostat
Wall-mounted on/off switch
Brown
White
Gold
Black
Aluminium
Alternative Grille Finishes
Space Saver models are suppliedwith a detachable brushed steelfascia grille. Fascia grilles are alsoavailable in the above colours.
Chrome
Accessories
All dimensions in mm
20322 91
89
62 Pipe centres
288
100135
500
475
9
100
SS5 Dual
SS80
SS3, SS5, SS5 12V, SS7
35696
63
88118
255
3 2520400
74
516550
See Glossary on page 46 for further information on Accessories
5. Plinth Heaters - Hydronic5.
Plin
th H
eate
rs -
Hyd
roni
c
45 www.SmithsEP.co.uk/domestic
6. Plinth Heaters - Electric
Space Saver
SS2E 290
105 105
91
240
100
500
485
9
All dimensions in mm
The Space Saver offers increased flexibility and space in kitchen design as it enables theremoval of radiators that may be using up valuable wall space. Fitting discreetly into theplinth of a kitchen, the Space Saver provides efficient and effective heat at low level.
Heat Output (kW) Power Consumption (kW) Fused Mains Sound Fascia Grille Fan-Only Model Spur Cable (m) Levels (dBA) Finish**Colour Electric
Space Saver SS3E 1kW/2kW/3kW 1kW/2kW/3kW 13A 2.0 42 Brushed Steel •
Space Saver SS2E 1kW/2kW 1kW/2kW 10A 2.0 42 Brushed Steel •
Space Saver SS80E 0.6kW/1.2kW 0.6kW/1.2kW 10A 23 38 Stainless Steel •
Before After
Additional information
Electric fan-assisted heaters cost around 15p per hour for each 1kW of heat.Hydronic models available.
Wall-mounted room thermostat
SS3E
Sound levels measured at 1.5m.
358 86
226
1219
121
586
600
60 97
Model shown SS2E, other models have different grille andswitch configurations.
SS80E
70 77
304
46078 78212
203 9
Space SaverFascia Grille Finish** - SS2E and SS3E
Zinc coated steel polyester, powder coated - metallic silver(referred to as Brushed Steel)
Fascia Grille Finish - SS80E
Stainless Steel
InstallationImportant: Correct fascia grille opening must be cut to
allow sufficient air intake • SS2E and SS3E - 20mm clearance above unit required SS80E - 10mm clearance above unit required • Model secured to plinth by two screws
through fascia grille • Unit must be earthedAccessories - SS2E
Wall-mounted room thermostat
Grilles: brown - RAL 8016, black - RAL 9005, white - RAL 9010, chrome, aluminium, gold
Alternative grilles for SS2E fit over the supplied grille
Wall-mounted control switch (white) to suit SS2E
Accessories - SS80, SS80E
Wall mounted room thermostat
Grilles: brown - RAL 8016, black - RAL 9005, white - RAL 9010
Controls
Overheat protection: thermal cut-out. Manual resetprocedure: switch power off at unit or mains, wait 5 minutes,switch power onSS2E - three rocker switches On/off, 1kW, 2kWSS3E - Push on/off switch, two rockers switches 1kW, 2kW, 3kWSS80E - three rocker switches On/off, 0.6kW, 1.2kW
See Glossary on page 46 for further information on Accessories
6.Pl
inth
Hea
ters
- El
ectr
ic
Glossary
Smith’s Accessories
Wall mounted room thermostat - This accessory measures room temperature and switches off theheater when the set temperature is reached. The thermostat connects directly into either the heater’sterminal block or power supply.
Wall mounted control switch - Allows the product to be controlled from a switch mounted on thewall rather than the product. Linking to the heater is made by replacing the existing switch connectionswith the connections on the control switch.
Flexible hoses - Flexible connections are a convenient way of connecting a heater into your system.They will provide an easy to achieve connection from your first-fix pipe work. In addition they willprovide for a level of expansion and contraction in rigid pipe work and mitigating possible sound andvibration transmission.
Adjustable low temperature cut-out (LTC) - This cut out device allows the user to set the watertemperature (between 30ºC and 90ºC) at which the product will start to emit heat. It is more accuratethan the standard fitted LTC (set at 35ºC) and enables more flexible use with both low systemtemperature heat pumps and higher system temperature boilers including biomass that can produce80ºC flow temperatures.
Plinth - The optional plinth creates an attractive floor standing unit and also conceals the pipe workfrom view. This can also be invaluable where it is necessary to prevent contact with heating pipes byvulnerable groups.
External control harness - This accessory allows up to four products to be controlled from a singlepoint. An External Control Harness will be required for each product. Each harness has plug and playconnections.
Proportional Heat Output Controller (PHOC) - This accessory controls the fan speed and hence theheat output of the unit. When the room temperature is below 15ºC the fan speed will run at itsmaximum speed to give fastest heat up time. When the room temperature reaches 15ºC the fan speedand heat output are modulated down progressively as the room temperature increases towards the settemperature.
Thermostat and Auto-Speed control (T1/T2) - This accessory serves two purposes. Firstly, it becomesan integral room thermostat for the unit providing localised control and secondly, the heat output willbe changed according to the temperature in the room. For example, the fan may work on full powerup to 18ºC and above this temperature move to a lower fan speed. Normally the fan speeds used willbe medium and low.
Fresh air inlet spigot - An air inlet spigot is available for 100mm diameter rigid or flexible pipe. Thespigot allows for a portion of air entering the appliance to be fresh air from outside the building. Thisensures an adequate air change rate and improved air quality.
Surface mounting kit - Provides a complete four-sided trim when fitted to a solid ceiling, 135 mm high.
Ceiling tile spacer - Provides semi-recessed profile to match Skyline CT18 when used in ceiling tileframe, 85mm high.
46 www.SmithsEP.co.uk
Glo
ssar
y
June 2017 - Issue 1
#ThinkSmiths
Happy to helpSmith's Environmental Products Ltd is one of the leading manufacturers of heating products in the UK. We are
committed to achieving the highest standards and our faith is supported by a free five year parts and labourguarantee with every product. Our customer service is second to none and we are happy to offer any help and
guidance that you might need.
StockistsAll products are available nationally from Builders’ Merchants, Plumbers’ Merchants, Heating Equipment
Distributors and Kitchen Equipment Distributors. In the event of difficulty, please contact us or visit our websitewww.SmithsEP.co.uk for details of your nearest stockist.
Information and adviceA product brochure containing full technical specifications and list prices is available to download from ourwebsite or in hard copy from our office. Also available on our website are price lists, individual product data
sheets, installation & user guides, where to buy, who to contact and a media centre.
Alternatively contact our office 9.00am to 5.00pm Monday to Friday.
For product information, customer services or sales support call us on
01245 324900For the Republic of Ireland, contact MT Agencies on 01 864 3363
[email protected]'s Environmental Products Ltd
Blackall Industrial Estate, South Woodham Ferrers, Chelmsford, Essex CM3 5UW
www.SmithsEP.co.uk