Commercial and Die Cast Fittings Conduit Fittings. . . . . . . . . . . . . . . . . . . . . . . . . . . . E2 Thinwall Conduit Fittings (EMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E3-E14 Rigid/Intermediate Grade Conduit Fittings . . . . . . . . . . . . . . . . . . . . . E15-E27 Rigid/Aluminum Conduit Bodies, Gaskets and Covers . . . . . . . . . . . . . . . . . E28-E29 Aluminum Conduit Bodies, Gaskets and Covers . . . . . . . . . . . . . . . . . . . . . E30 Flexible Cord and Power Cable Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . E31 Liquidtight Flexible Nonmetallic Conduit Connectors and Tubing . . . . . . . . E32-E33 Liquidtight Fittings. . . . . . . . . . . . . . . . . . . . . . . . . E34 Liquidtight Flexible Metal Conduit Connectors . . . . . . . . . . . . . . . . . . E35-E37 Nonmetallic Sheathed Cable and Flexible Cord Connectors . . . . . . . . . . . . . . . . . E38 Nonmetallic Sheathed Cable Fittings . . . . . . . . . . . . . . . . . . . . . . . E39-E40 Armored Cable/Flexible Metallic Conduit Fittings . . . . . . . . . . . . . . . . . . . . . E41-E46 Cable Straps, Cable Caps . . . . . . . . . . . . . . . . . . E47 Service Entrance Fittings . . . . . . . . . . . . . . . . . . . E48 Grounding Clamps/Connectors . . . . . . . . . . . . . . E49 Gutter Connectors/Cable Protector and Cable Clip . . . . . . . . . . . . . . . . . . . . . . . . . . E50 Beam Clamps for Mounting Pipe or Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E51 Conduit and Pipe Hangers . . . . . . . . . . . . . . . . . . E52 Beam Clamps/Threaded Rod/ Rod Coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . E53 E

Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

Commercial and Die Cast Fittings

Conduit Fittings. . . . . . . . . . . . . . . . . . . . . . . . . . . . E2

Thinwall Conduit Fittings (EMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E3-E14

Rigid/Intermediate Grade Conduit Fittings . . . . . . . . . . . . . . . . . . . . . E15-E27

Rigid/Aluminum Conduit Bodies,Gaskets and Covers . . . . . . . . . . . . . . . . . E28-E29

Aluminum Conduit Bodies,Gaskets and Covers . . . . . . . . . . . . . . . . . . . . . E30

Flexible Cord and Power CableConnectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . E31

Liquidtight Flexible Nonmetallic Conduit Connectors and Tubing . . . . . . . . E32-E33

Liquidtight Fittings. . . . . . . . . . . . . . . . . . . . . . . . . E34

Liquidtight Flexible Metal Conduit Connectors . . . . . . . . . . . . . . . . . . E35-E37

Nonmetallic Sheathed Cable andFlexible Cord Connectors . . . . . . . . . . . . . . . . . E38

Nonmetallic SheathedCable Fittings . . . . . . . . . . . . . . . . . . . . . . . E39-E40

Armored Cable/Flexible MetallicConduit Fittings . . . . . . . . . . . . . . . . . . . . . E41-E46

Cable Straps, Cable Caps . . . . . . . . . . . . . . . . . . E47

Service Entrance Fittings . . . . . . . . . . . . . . . . . . . E48

Grounding Clamps/Connectors . . . . . . . . . . . . . . E49

Gutter Connectors/Cable Protectorand Cable Clip . . . . . . . . . . . . . . . . . . . . . . . . . . E50

Beam Clamps for Mounting Pipeor Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E51

Conduit and Pipe Hangers . . . . . . . . . . . . . . . . . . E52

Beam Clamps/Threaded Rod/Rod Coupling. . . . . . . . . . . . . . . . . . . . . . . . . . . E53

E

412034.E01 5/7 5/7/03 4:51 PM Page E1

Page 2: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

Steel City® Conduit Fittings provide long-lasting service in commercial,industrial and residential construction. Our fittings are manufacturedwithin strict tolerances to maintain consistent performance. Installerscan be assured that every fitting with the Steel City name will work

every time. So when you select Steel City® Conduit Fittings, thatmeans fewer headaches and call-backs.

Steel City® products symbolize the highest quality standards inmanufacturing and innovative design, with one of the mostcomplete offerings available. Contact a T&B distributor nearestyou to select the right Steel City® product for your requirements.

E2 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Conduit Fittings

Advantages of Steel City Commercial Conduit Fittings

Compression FittingsDependable Pipe Stop• Strong thick protrusion that does not exceed thickness of EMT. Keeps forcefully inserted

conduit from breaking through the opposite side of the coupling while not interfering with thepulling of conductors.

Heavy Duty Thick Steel Body/Glands withContinuous Threading• True hexagonal shape. The non-circular design

has actual flats for gripping power using hand ortool force.

Extra Thick Electroplated Zinc Finish • Assures corrosion resistance while the clear

chromate coating gives the fittings their qualityshine and luster.

Couplings and ConnectorsSuperior Quality and Design• Strict tolerances throughout fitting assures a straight conduit run with no

sagging over extreme lengths. • Chamfered entry provides lead-in for conduit insertion.

Dependable Pipe Stop• 360° grove traveling the circumference assures that conduit forcefully

inserted won't break through to the opposite side of the fitting. Also, itdoes not exceed thickness of EMT and prevents interference withpulling conductors.

Extra Large Head Tri-Drive Set-Screw • Accommodates Phillips, Slotted and Square

drives.

Enhanced LocknutConstruction• Heavy-duty turned sharp

teeth, double-threaded.

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E2

Page 3: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E3

Thinwall Conduit Fittings (EMT)

1st Digit – Material1 = Steel2 = Die Cast3 = Combination Steel and Die Cast4 = Malleable5 = Plastic6 = Aluminum7 = Steel Insulated8 = Die Cast Insulated9 = Malleable Insulated

2nd Digit – Method1 = Compression2 = Set Screw3 = Other

3rd/4th Digit Size1 = d"2 = f"3 = 1"4 = 1b"5 = 1d"6 = 2"7 = 2d"8 = 3"9 = 3d"10 = 4"11 = 5"12 = 6"A few examples of the three digitidentification system for thinwallfittings are:TK-111 d" steel, compression

type couplingTC-714 1b" steel insulated

compression typeconnector

TC-822 f" die cast, insulated,set-screw typeconnector

Easy to identify alphabetical prefixes:BG – Bushings, GroundingBI – Bushings, InsulatedBL – BlanksBU – BushingsCB – Clamp BackEK – 3 Piece CouplingGA – Ground Clamp (armored ground

wire)GC – Ground ClampHA – Heavywall AdapterHC – Heavywall ConnectorHK – Heavywall CouplingHO – Heavywall OffsetHS – Heavywall StrapLG – Locknut, GroundingLN – LocknutLT – LiquidtightNC – Nonmetallic Sheathed Cable

ConnectorNS – Nonmetallic Sheathed Cable

StrapSH – Service Entrance FittingSL – Service EllsSR – Sealing RingsLS – Locknut, SealingTC – Thinwall ConnectorsTK – Thinwall CouplingsTO – Thinwall OffsetTS – Thinwall StrapTX – Thinwall to Flexible Metallic

Conduit FittingUC – Utility ConnectorWA – WasherXC – Armored Cable or Flexible

Metallic Conduit ConnectorXK – Armored Cable or Flexible

Metallic Conduit Coupling

Here’s How The Steel City Part Number System Works

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E3

Page 4: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E4 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Thinwall Conduit Fittings (EMT)

Set Screw Connectors, Steel – Non-Insulated"A" Cat# Conduit Size Inner Pack Outer Pack

TC121A d" 50 500TC122A f" 50 250TC123A 1" 25 100TC124A 1b" – 25TC125A 1d" – 25TC126A 2" – 25TC127A 2d" – 10TC128A 3" – 5TC129A 3d" – 5TC1210A 4" – 5

Set Screw Connectors, Steel – Insulated"A" Cat# Conduit Size Inner Pack Outer Pack

TC721A d" 50 500TC722A f" 50 250TC723A 1" 25 100TC724A 1b" – 25TC725A 1d" – 25TC726A 2" – 25TC727A 2d" – 10TC728A 3" – 5TC729A 3d" – 5TC7210A 4" – 5

U.L. File No. E-16592

• Concrete Tight• Zinc Plated

NewDesign

®

Set Screw Couplings – Steel"A" Cat# Conduit Size Inner Pack Outer Pack

TK121A d" 50 500TK122A f" 50 250TK123A 1" 25 100TK124A 1b" – 25TK125A 1d" – 25TK126A 2" – 25TK127A 2d" – 10TK128A 3" – 5TK129A 3d" – 5TK1210A 4" – 5

U.L. File No. E-16592• Concrete Tight, when taped• Zinc Plated

NewDesign

®

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E4

Page 5: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E5

Thinwall Conduit Fittings (EMT)

Compression Connectors, Steel – Non-Insulated"A" Cat# Conduit Size Inner Pack Outer Pack

TC111A d" 50 500TC112A f" 50 250TC113A 1" 25 100TC114A 1b" – 25TC115A 1d" – 25TC116A 2" – 25TC117A 2d" – 10TC118A 3" – 5TC119A 3d" – 5TC1110A 4" – 5

Compression Connectors, Steel – Insulated"A" Cat# Conduit Size Inner Pack Outer Pack

TC711A d" 50 500TC712A f" 50 250TC713A 1" 25 100TC714A 1b" – 25TC715A 1d" – 25TC716A 2" – 25TC717A 2d" – 10TC718A 3" – 5TC719A 3d" – 5TC7110A 4" – 5

U.L. File No. E-16592

• 1⁄2" – 4" Concrete Tight• Zinc Plated

NewDesign

®

Compression Couplings – Steel"A" Cat# Conduit Size Inner Pack Outer Pack

TK111A d" 50 250TK112A f" 50 250TK113A 1" 25 100TK114A 1b" – 25TK115A 1d" – 25TK116A 2" – 25TK117A 2d" – 10TK118A 3" – 5TK119A 3d" – 5TK1110A 4" – 5

U.L. File No. E-16592• 1⁄2" – 4" Concrete Tight• Zinc Plated

NewDesign

®

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E5

Page 6: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E6 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Thinwall Conduit Fittings (EMT)

EMT LOK Conduit ConnectorCat. Std.No. Description Ctn.

TC-101-SC d" Uninsulated 500TC-102-SC f" Uninsulated 250TC-701-SC d" Insulated 500TC-702-SC f" Insulated 250

U.L. Listing No. E16592, CSA Listing No. LR-12798Installation using either slotted or Phillips screwdriver head, 35-in-lb of torque onto the EMT.NOTE: Excessive torque could damage EMT or housing.• Simple, one-piece installation with no

locknuts.• Available in insulated or noninsulated throat.• Screw designed for exceptional pullout

resistance.• Captive screw ensures that the screw is intact

for installation and resists backing out afterinstallation.

• Corrosion-resistant, zinc-chromatic plating.• Concrete tight.• Positive grounding.• Vibration resistant screw design.• UL listed and CSA certified.

®®

E

Stee

l Cit

Steel City ® Steel Boxes, Covers, & Accessories• Notched Ears on Switch Boxes provide clearance for the screws that are used to attach

wall plates to GFCI or rocker-type light switches.• Universal Metal Stud Bracket mounts without the use of screws, to the open or closed

side of the stud and works on any depth of non-loadbearing metal stud.• Eccentric Knockouts on Square Boxes provide better contact with conduit fitting

and locknut to the box, improves grounding path, stronger than f" knockout.• Improved f" Knockout Position on Square Boxes requires less labor to

install f" conduit to box.• Raised Ground Screw in Utility Boxes make for quicker surface

mounting by eliminating the need to remove the portion of the screw thatthreads through the back of the box, allows for improved repositioning ofgrounding conductor.

• Preinstalled Screws are Packaged in raised position eliminates extra step ofhaving to back out the screw during cover installation.

Steel City ® Underfloor Duct, Floor Boxes, & Poke-Throughs• Steel City conventional underfloor duct offers multi-compartmental duct and junction boxes with built-

in tile trim.• Header duct and access hatch designs of cellular underfloor duct system provide convenient

wire and cable access, eliminating junction boxes.• Accommodate power, voice, or data with Steel City flush floor boxes, available in cast-iron,

steel, and nonmetallic constructions.• Access floor modules blend with any decor and accommodate virtually any raised floor

surface.• Steel City poke-through devices allow the interchange of flush, low-profile, and standard

service heads without removing the lower core unit.

Additional Commercial Construction Products from Thomas & Betts

412034.E01 5/7 5/7/03 4:52 PM Page E6

Page 7: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E7

Thinwall Conduit Fittings (EMT)

Compression Connectors – Die Cast Zinc, InsulatedCat. Conduit Std.No. Size A B Ctn.

TC-811-SC d" 1R" ©" 500TC-812-SC f" 1v" n" 250TC-813-SC 1" 1{" 1v" 200TC-814-SC 1b" 1C" 1B" 100TC-815-SC 1d" 1O" 2h" 40TC-816-SC 2" 2b" 2w" 20TC-817-SC 2d" 2A" 3b" 12TC-818-SC 3" 2O" 3n" 12TC-819-SC 3d" 2B" 4k" 10TC-8110-SC 4" 2C" 4n" 6

U.L. File No. E-16592 – d"-4"CSA File No. LR-12798 – d"-2

• 1⁄2" – 4" Concrete Tight

A

B

Offset Compression Connectors – Die Cast ZincCat. Conduit Std.No. Size A B Ctn.

TO-211SC c" offset d" 2$" 1" 200TO-212 f" offset f" 2.98" 1.16" 100

U.L. File No. E-16592

A

B

Compression Couplings – Die Cast ZincCat. Conduit Std.No. Size A B Ctn.

TK-211-SC d" 1d" 1p" 500TK-212-SC f" 1e" 1j" 250TK-213-SC 1" 1g" 1}" 200TK-214-SC 1b" 1m" 2p" 100TK-215-SC 1d" 2s" 2Q" 40TK-216-SC 2" 2X" 2C" 20TK-217-SC 2d" 3$" 3™" 12TK-218-SC 3" 3r" 4d" 12TK-219-SC 3d" 3!" 5h" 10TK-2110-SC 4" 3i" 5G" 6

U.L. File No. E-16592 – d"-4"CSA File No. LR-12798 – d"-1b", 2d"-4"

®®

®®

®

• 1⁄2" – 4" Concrete Tight

A

B

Compression Connectors – Die Cast Zinc, NoninsulatedCat. Conduit Std.No. Size A B Ctn.

TC-211-SC d" 1b" 1 500TC-212-SC f" 1X" 1q" 250TC-213-SC 1" 1S" 1v" 200TC-214-SC 1b" 1m" 1B" 100TC-215-SC 1d" 1g" 2h" 40TC-216-SC 2" 2q" 2w" 20TC-217-SC 2d" 2}" 3b" 12TC-218-SC 3" 2g" 3n" 12TC-219-SC 3d" 2I" 4k" 10TC-2110-SC 4" 2m" 4n" 6

U.L. File No. E-16592 – d"-4"CSA File No. LR-12798 – d"-2

®®

• 1⁄2" – 4" Concrete Tight

A

B

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E7

Page 8: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

Set Screw Connectors – Die Cast Zinc, NoninsulatedCat. Conduit A Std.No. Size TC-221 Series TC-821 Series B Ctn.

TC-221-SC d" 1q" 1å" n" 500TC-222-SC f" 1u" 1E" 1q" 250TC-223-SC 1" 1l" 1y" 1N" 200TC-224-SC 1b" 1n" 2o" 1m" 100TC-225-SC 1d" 2s" 2c" 2Y" 40TC-226-SC 2" 2E" 2T" 2w" 20TC-227-SC 2d" 3i" 3s" 3∫" 12TC-228-SC 3" 3ç" 3M" 4h" 12TC-229-SC 3d" 3M" 3x" 4w" 10TC-2210-SC 4" 3I" 3K" 5h" 6

NoninsulatedU.L. File No. E-16592 – d"-2"U.L. File No. E-1275 – 2d"-4"CSA File No. LR-12798 – d"-1", 2d"-4"

Set Screw Connectors – Die Cast Zinc, InsulatedCat. Conduit A Std.No. Size TC-221 Series TC-821 Series B Ctn.

TC-821-SC d" 1q" 1å" n" 500TC-822-SC f" 1u" 1E" 1q" 250TC-823-SC 1" 1l" 1y" 1N" 200TC-824-SC 1b" 1n" 2o" 1m" 100TC-825-SC 1d" 2s" 2c" 2Y" 40TC-826-SC 2" 2E" 2T" 2w" 20TC-827-SC 2d" 3i" 3s" 3∫" 12TC-828-SC 3" 3ç" 3M" 4h" 12TC-829-SC 3d" 3M" 3x" 4w" 10TC-8210-SC 4" 3I" 3K" 5h" 6

InsulatedU.L. File No. E-16592 – d"-2"U.L. File No. E-1275 – 2d"-4"CSA File No. LR 12798 – d"-2"

E8 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Thinwall Conduit Fittings (EMT)

• Concrete Tight, when taped

A

B

• Concrete Tight, when taped

Set Screw Couplings – Die Cast ZincCat. Conduit Std.No. Size A B Ctn.

TK-221 d" 1E" ∂" 500TK-222 f" 1C" 1q" 250TK-223 1" 2" 1k" 200TK-224 1b" 2E" 1B" 100TK-225 1d" 2B" 2h" 40TK-226 2" 3u" 2d" 20TK-227 2d" 4r" 3∫" 12TK-228 3" 4W" 4Y" 12TK-229 3d" 4B" 4w" 10TK-2210 4" 5v" 4l" 6

U.L. File No. E-16592 – d"-2"U.L. File No. E-1275 – 2d"-4"CSA File No. LR-12798 – d"-1b", 2d"-4"

®®

®®

• Concrete Tight, when taped

A

B

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E8

Page 9: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E9

Thinwall Conduit Fittings (EMT)

Capped Corner Couplings – Die-Cast ZincCat. Conduit Std.No. Size A B Ctn.

TL-291 d" 1.81" 1.00" 100TL-292 f" 2.00" 1.25" 50

U.L. File No. E-16592CSA File No. LR-12798

• Concrete Tight, when taped

• Concrete Tight, when taped

EMT to Box Set Screw Type – Die-Cast ZincCat. Conduit Std.No. Size A B Ctn.

TL-211 d" 1.31" .93" 100TL-212 f" 1.47" 1.22" 50

U.L. File No. E-1275

EMT to EMT Set Screw Type – Die-Cast ZincCat. Conduit Std.No. Size A B Ctn.

TL-201 d" 1.31" 1.10" 100TL-202-SC f" 1.60" 1.24" 50TL-203 1" 1.94" 1.59" 25TL-204 1b" 2.26" 1.97" 25

U.L. File No. E-1275

Set Screw Connectors – Die-Cast Zinc, OffsetCat. Conduit Std.No. Offset Size A B C Ctn.

TO-221 c" d" 2.00" .90" .37 100TO-222 f" f" 2.98" 1.16" .25 100TO-223 f" 1" 3.15" 1.42" .75 100

U.L. File No. E-16592CSA File No. LR-18130M57

SET SCREW TYPE

B C

A

COMPRESSION TYPE

B C

A

EMT Connectors 90° Angle – Die Cast ZincCat. Trade Std.No. Size A B C Ctn.

SET SCREW TYPE

TC-921 d" 1.27 1.15 .45 200COMPRESSION TYPE

TC-911-SC d" 1.37 1.15 .45 200TC-912-SC f" 1.86 .95 .52 200

®

®®

®®

®

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E9

Page 10: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

Thinwall Conduit Fittings (EMT)

E10 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Combination Set Screw Couplings – Die-Cast Zinc Flexible Metal Conduit to EMT

Cat. Conduit Std.No. Size A B Ctn.

TX-220 c" flex to d" EMT 1e" d" 500TX-221 d" flex to d" EMT 1m" 1q" 250TX-222 f" flex to f" EMT 1O" 1X" 150TX-223 1" flex to 1" EMT 2ƒ" 1e" 150

U.L. File No. E-1275• Concrete Tight, when taped

A

B

Combination Set Screw Couplings – Thinwall to Heavywall – Die-Cast Zinc

Cat. Conduit Std.No. Size A B Ctn.

HT-221 d" EMT to d" Rigid 1.67" 1.07" 500HT-222 f" EMT to f" Rigid 1.98" 1.29" 250HT-223 1" EMT to 1" Rigid 2.15" 1.58" 100

U.L. File No. E-1275• Concrete Tight, when taped

Combination Compression Couplings – Thinwall to Liquidtight Flexible Metal Conduit – Steel

Cat. Conduit Std.No. Size A B C Ctn.

LTT-111 d" EMT to d" Liquidtight 1f" n" 1a" 100LTT-112 f" EMT to f" Liquidtight 1f" 1™" 1c" 50LTT-113 1" EMT to 1" Liquidtight 1n" 1d" 1f" 25• Steel

• Rain Tight• Zinc Plated

A

CCorner

BCorner

Combination Compression Couplings – Heavywall to Liquidtight Flexible Metal Conduit – Steel

Cat. Conduit Std.No. Size A B C Ctn.

LTH-111 d" Rigid to d" Liquidtight 1g" 1a" 1a" 100

• Steel• Rain Tight• Zinc Plated

A

CCorner

BCorner

®

®

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E10

Page 11: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E11

Thinwall Conduit Fittings (EMT)

Combination Couplings – EMT to Flex Compression to Screw-In Type – Die Cast Zinc

Cat. Trade Std.No. Size A B Ctn.

TX-201 d" 0.84 1.10 500TX-202 f" 0.95 1.30 250

Combination Couplings – EMT to Flex Set Screw Type – Die Cast Zinc

Cat. Trade Std.No. Fig. # Size A-Min A-Max B Ctn.

TX-210 1 d" - c" 0.15 0.61 1.16 250TX-211 2 d" - d" 0.60 1.00 1.71 250TX-212 2 f" - f" 0.78 1.20 1.93 200

Fig. “1”d"–c"

Fig. “2”d"–d" f"–f"

One Hole Snap-Straps – SteelCat. Conduit Std.No. Size A B Ctn.

TS-101 d" 0.57" 1.79" 1000TS-102 f" 0.62" 1.96" 500TS-103 1" 0.75" 2.25" 500TS-104 1b" 0.88" 2.85" 250TS-105 1d" 0.99" 3.16" 100TS-106 2" 1.10" 3.93" 50HS-107 2d" 1.28" 5.00" 25HS-108 3" 1.28" 5.55" 25HS-109 3d" 1.28" 6.37" 10HS-110 4" 1.28" 6.87" 10

A

B

• Steel• Zinc Plated

Pipe Spacers for Thinwall or Heavywall – Die CastCat. Conduit Std.No. Size A B Ctn.

CB-201 d" 2" 1" 1000CB-202 f" 2c" 1h" 500CB-203 1" 2f" 1j" 500CB-204 1a" 2c" 1d" 250CB-205 1d" 3m" 1e" 100CB-206 2" 4d" 2" 50

A

B

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E11

Page 12: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

Thinwall Conduit Fittings (EMT)

E12 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Two Hole EMT Straps – SteelCat. Conduit Std.No. Size A B Ctn.

TS-901 d" 0.56" 2.20" 250TS-902 f" 0.62" 2.67" 200TS-903 1" 0.68" 2.97" 100TS-904 1b" 0.75" 3.67" 50TS-905 1d" 0.88" 4.22" 200TS-906 2" 1.00" 4.91" 25

• Steel• Zinc Plated

A

B

Nail Strap – SteelCat. Rigid/MC EMT Flex Std.No. Size Size Size A B Ctn.

N-101-SC – d" c" 1n" 1Z" 1000N-102-SC d" f" d" 2i" 1w" 1000N-103-SC f" 1" – 2c" 1v" 1000

• Stamped Steel• Zinc Plated

B

A

Space Caps – PlasticCat. Conduit Std.No. Size A B Ctn.

BT-501 d" 2v" 1E" 100BT-502 f" 2v" 1I" 100BT-503 1" 2v" 1O" 100BT-504 1b" 2v" 2M" 100BT-505 1d" 2v" 3o" 100

A

B

Space Cap

EMT Connector

EMT Connectors – Two Piece Type – Die Cast ZincCat. Trade Std.No. Size A B Ctn.

TC-201-SC d" 0.68 1.05 1000

UL File No. E16592

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E12

Page 13: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E13

Aluminum Conduit Bodies, Covers and Gaskets – LB StyleCat. Trade Std.No. Size A B Ctn.

BLB-1 d" 3g 2h 50BLB-2 f" 4e 2k 50BLB-3 1" 5c 2f 25BLB-4 1b" 7b 3l 10BLB-5 1d" 7b 3m 10BLB-6 2" 9d 4d 5BLB-7* 2d" 12b 5b 1BLB-8* 3" 12b 5g 1BLB-9* 3d" 15 6n 1BLB-10* 4" 15 6n 1

* Shipped with cover. Price includes cost of cover and body.

Thinwall Conduit Fittings (EMT)

TYPE BLR

TYPE BLL

Aluminum Conduit Bodies, Covers and Gaskets – LR StyleCat. Trade Std.No. Size A B Ctn.

BLR-1 d" 3g 2 50BLR-2 f" 4e 2j 50BLR-3 1" 5c 2d 25BLR-4 1b" 7b 3c 10BLR-5 1d" 7b 3c 10BLR-6 2" 9d 3n 5BLR-7* 2d" 12b 5d 1BLR-8* 3" 12b 5d 1BLR-9* 3d" 15 6d 1BLR-10* 4" 15 6d 1

* Shipped with cover. Price includes cost of cover and body.

Aluminum Conduit Bodies, Covers and Gaskets – LL StyleCat. Trade Std.No. Size A B Ctn.

BLL-1 d" 3g 2 50BLL-2 f" 4e 2j 50BLL-3 1" 5c 2d 25BLL-4 1b" 7b 3c 10BLL-5 1d" 7b 3c 10BLL-6 2" 9d 3n 5BLL-7* 2d" 12b 5d 1BLL-8* 3" 12b 5d 1BLL-9* 3d" 15 6d 1BLL-10* 4" 15 6d 1

* Shipped with cover. Price includes cost of cover and body.

®

®

Aluminum Conduit Bodies, Covers and Gaskets – C StyleCat. Trade Std.No. Size A B Ctn.

BC-1-RD d" 3g 1Q 50BC-2-RD f" 4e 1w 50BC-3 1" 5c 1f 25BC-4 1b" 7b 2d 10BC-5 1d" 7b 2d 10BC-6 2" 9d 3a 5BC-7* 2d" 12b 4d 1BC-8* 3" 12b 4d 1BC-9* 3d" 15 5d 1BC-10* 4" 15 5d 1

* Shipped with cover. Price includes cost of cover and body.

TYPE BC

TYPE BLB

®

®

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E13

Page 14: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

Thinwall Conduit Fittings (EMT)

E14 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

TYPE BT

Aluminum Conduit Bodies, Covers and Gaskets – T StyleCat. Trade Std.No. Size A B Ctn.

BT-1 d" 3g 2h 50BT-2 f" 4e 2X 50BT-3 1" 5c 2e 25BT-4 1b" 7b 3w 10BT-5 1d" 7b 3w 10BT-6 2" 9d 4 5BT-7* 2d" 12b 5A 1BT-8* 3" 12b 5A 1BT-9* 3d" 15 6m 1BT-10* 4" 15 6m 1

* Shipped with cover. Price includes cost of cover and body.

Aluminum Conduit Bodies, Covers and Gaskets – LR StyleCat. Trade Std.No. Size A B Ctn.

BLRL-1 d" 3g 2 50BLRL-2 f" 4e 2j 50BLRL-3 1" 5c 2d 25BLRL-4 1b" 7b 3c 10BLRL-5 1d" 7b 3c 10BLRL-6 2" 9d 3n 5

* Shipped with cover. Price includes cost of cover and body.

TYPE BLRL

®

Fiber Gasket

Neoprene Gasket

• Stamped aluminum(1⁄2" thru 2" sizes) ordie cast aluminum(21⁄2" thru 4" sizes).

• Steel zinc platedscrews.

• Fiber or neoprene material

Aluminum Covers with Stainless Steel Screws

Cat. Conduit Std.No. Size Ctn.

CV-1 d" 250CV-2 f" 250CV-3 1" 250CV-4 1b" - 1d" 50CV-5 2" 25CV-6 2d" - 3" 5CV-7 3d" - 4" 5

SCV-1 d" 250SCV-2 f" 250SCV-3 1" 250SCV-4 1b" - 1d" 250SCV-5 2" 100

Gaskets – CompositionCat. Conduit Std.No. Size Ctn.

GKV-1 d" 100GKV-2 f" 50GKV-3 1" 25GKV-4 1b" - 1d" 25GKV-5 2" 25GKV-6 2d" - 3" 5GKV-7 3d" - 4" 5

Gaskets – NeopreneCat. Conduit Std.No. Size Ctn.

GKN-1 d" 100GKN-2 f" 50GKN-3 1" 25GKN-4 1b" - 1d" 25GKN-5 2" 25GKN-6 2d" - 3" 5GKN-7 3d" - 4" 5

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E14

Page 15: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E15

Rigid/Intermediate Grade Conduit Fittings

Snap in BlanksCat. Conduit Std.No. Size Diameter Ctn.

BL-111 d" 1Z" 1000BL-112 f" 1b" 1000BL-113 1b" 1d" 1000BL-114 1" 1m" 500BL-115 1d" 2r" 500BL-116 2" 2W" 250

• Steel• Zinc Plated

A

BBox Spacer – Die-Cast Zinc (b" space)

Cat. Conduit Std.No. Size A B Ctn.

BS-201 d" 1a" u" 500

U.L. File No. E-1275

Threadless Compression ConnectorsCat. Conduit Std.No. Size Ctn.

HC-401 d" 300HC-402 f" 150HC-403 1" 90HC-404 1b" 60HC-405 1d" 30HC-406 2" 12HC-407 2d" 12HC-408 3" 6HC-409 3d" 6HC-410 4" 6

Suggested use – rigid conduit only.U.L. File No. E-1275 d" thru 1b"

• 1⁄2"-21⁄2" – Steel• 3"-4" – Malleable Iron/Zinc plated

• 1⁄2"-21⁄2" – Steel• 3"-4" – Malleable Iron/Zinc plated

Threadless Compression CouplingsCat. Conduit Std.No. Size Ctn.

HK-401 d" 300HK-402 f" 150HK-403 1" 90HK-404 1b" 60HK-405 1d" 30HK-406 2" 6HK-407 2d" 6HK-408 3" 4HK-409 3d" 4HK-410 4" 4

Suggested use – rigid conduit only.U.L. File No. E-1275 d" thru 1b"

®

®

®

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E15

Page 16: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E16 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Rigid/Intermediate Grade Conduit Fittings

Set Screw ConnectorsCat. Conduit Std.No. Size A B Ctn.

HC-101 d" 1a" 1a" 100HC-102 f" 1c" 1d" 50HC-103 1" e" 1m" 50HC-104 1b" 2" 2" 25HC-105 1d" 2d" 2c" 25HC-106 2" 2f" 2c" 20HC-107 2d" 3u" 3j" 10HC-108 3" 4o" 3k" 5HC-109 3d" 4l" 3m" 5HC-110 4" 5p" 4p" 5

One Set Screw or TwoTwo set screws starting at 2" Trade SizeSuggested use – rigid conduit onlyU.L. File No. E-1275 d" thru 1b"

A

B

Set Screw Connectors – InsulatedCat. Conduit Std.No. Size A B Ctn.

HC-701 d" 1a" 1a" 100HC-702 f" 1c" 1d" 50HC-703 1" e" 1m" 25HC-704 1b" 2" 2" 25HC-705 1d" 2d" 2c" 25HC-706 2" 2f" 2c" 20HC-707 2d" 3u" 3j" 10HC-708 3" 4o" 3k" 5

One Set Screw or TwoTwo set screws starting at 2" Trade SizeSuggested use – rigid conduit onlyU.L. File No. E-1275 d" thru 1b"

• Steel (concrete tight), when taped• Zinc plated

• Steel (concrete tight), when taped• Zinc plated

Set Screw CouplingsCat. Conduit Std.No. Size A B Ctn.

HK-101 d" 1a" 2u" 100HK-102 f" 1c" 2w" 50HK-103 1" 1e" 2W" 25HK-104 1b" 2" 2A" 25HK-105 1d" 2b" 3™" 25HK-106 2" 2f" 3u" 20HK-107 2d" 3k" 3C" 10HK-108 3" 4h" 4q" 5HK-109 3d" 4l" 4g" 5HK-110 4" 5h" 5c" 5

Two set screws starting at 2".U.L. File No. E-1275

A

B

• Steel (concrete tight), when taped• Zinc plated

®

A

B

®

®

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E16

Page 17: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E17

Rigid/Intermediate Grade Conduit Fittings

Rigid Connector

Rigid Connectors – Set Screw Type – Die Cast ZincCat. Conduit Std.No. Size A B Ctn.

HC-201 d" 1.34 0.39 250HC-202 f" 1.44 0.45 250HC-203 1" 1.54 0.49 100

WITH INSULATED THROAT

HC-801 d" 1.34 0.39 250HC-802 f" 1.44 0.45 250HC-803 1" 1.54 0.49 100

Rigid Coupling

Rigid Couplings – Set Screw Type – Die Cast ZincCat. Trade Std.No. Size A B Ctn.

HK-201 d" 1.77 1.09 250HK-202 f" 2.06 1.34 250HK-203 1" 2.29 1.61 100

90° Short Radius Elbows – Die Cast ZincCat. Size Dimensions (in.) Shf. Ctn./No. (in.) A B Ship Qty.

HL-201-SC d" .98 .96 50/500HL-202-SC f" 1.17 1.04 25/250

USE: To join rigid or IMC conduit at right angles where lack of room prevents using a standard sweep elbow, or toterminate a run of rigid or IMC conduit at a box.UL Listing E37148

A

B

Three Piece CouplingsCat. Conduit Dimensions (in.) Shf. Ctn./No. Size A (Assembled) B Ship Qty.

EK-401 d" 1h" 1a" 100EK-402 f" 1a" 1X" 50EK-403 1" 1c" 1e" 25EK-404 1b" 1y" 2q" 25EK-405 1d" 1g" 2z" 25EK-406 2" 2" 3E" 20EK-407 2d" 2d" 3S" 10EK-408 3" 3c" 4z" 6EK-409 3d" 3e" 5q" 5EK-410 4" 3C" 5C" 5EK-411 5" 4j" 7" 1EK-412 6" 4l" 8a" 1

U.L. File No. E-1275 d" thru 4"• 1⁄2"-21⁄2" – Steel• 21⁄2"-6" – Malleable Iron• Zinc plated

®

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E17

Page 18: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E18 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Pull Corner Elbows – Die Cast ZincCat. Conduit Std.No. Size A B Ctn.

HL-601 d" 1.31" 1.10" 100HL-602 f" 1.60" 1.24" 50HL-603 1" 1.95" 1.59" 25HL-604 1b" 2.26" 1.97" 30

U.L. File No. E-1275

Rigid to Box with Gasket – Die-Cast ZincCat. Conduit Std.No. Size A B Ctn.

HL-611 d" 1.31" 1.09 100HL-612 f" 1.47" 1.29" 50

U.L. File No. E-1275

The T&B Hub Zinc Die Cast with Insulated Throat*Cat. Hub Std.No. Size Ctn.

H050-SC d" 100H075-SC f" 100H100-SC 1" 25H125-SC 1b" 25H150-SC 1d" 10H200-SC 2" 5H250-SC 2d" 5H300-SC 3" 2H350-SC 3d" 2H400-SC 4" 1H500-SC 5" 1H600-SC 6" 1

*Available in Nickel-Chrome plating. Consult customer service for price and delivery.*Available with PVC coating. Consult customer service for price and delivery.

• The T&B Hub with sealing ring will notfall out.

• Provides superior sealing for exceptionalwatertight performance.

H050-SC Series Hub

Rigid Couplings – Three Piece Type – Die Cast ZincCat. Trade Std.No. Size A B Ctn.

EK-201 d" 1.39 1.31 100EK-202 f" 1.53 1.58 50

®

®

Rigid/Intermediate Grade Conduit Fittings

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E18

Page 19: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

Conduit Nipples – Die Cast Zinc – InsulatedCat. Conduit Std.No. Size A B Ctn.

HA-801 d" 0.98" 0.59" 1000HA-802 f" 1.18" 0.70" 500HA-803 1" 1.50" 0.80" 250HA-804 1b" 1.75" 1.06" 250HA-805 1d" 2.11" 1.01" 100HA-806 2" 2.61" 1.20" 40HA-807 2d" 3.13" 1.49" 25HA-808 3" 3.90" 1.65" 10HA-809 3d" 4.20" 1.68" 10HA-810 4" 4.79" 1.73" 10

U.L. File No. E-1275 d" & f“ only

Conduit Nipples – Iron/Zinc PlatedCat. Conduit Std.No. Size A B Ctn.

841-TB c" l" W" 500HA-401 d" W" n" 500HA-402 f" m" 1r" 200HA-403 1" g" 1k 100HA-404 1b" 1a" 1f" 100HA-405 1d" 1a" 2h" 50HA-406 2" 1k" 2l" 50HA-407 2d" 1b" 3" 20HA-408 3" 1d" 3g" 10HA-409 3d" 1f" 4c" 5HA-410 4" – – 5HA-411 5" – – 1HA-412 6" – – 1

U.L. File No. E-1275 c"-3d"

B

A

B

A

Conduit Nipples – Insulated Iron/Zinc PlatedCat. Conduit Std.No. Size A B Ctn.

HA-901 d" W" n" 500HA-902 f" m" 1r" 200HA-903 1" g" 1k" 100HA-904 1b" 1a" 1f" 100HA-905 1d" 1a" 2h" 50HA-906 2" 1k 2l" 50

Conduit Nipples – Die Cast Zinc – NoninsulatedCat. Conduit Std.No. Size A B Ctn.

HA-201 d" 0.98" 0.59" 1000HA-202 f" 1.18" 0.70" 500HA-203 1" 1.50" 0.80" 250HA-204 1b" 1.75" 1.06" 250HA-205 d" 2.11" 1.01" 100HA-206 2" 2.61" 1.20" 40HA-207 2d" 3.13" 1.49" 40HA-208 3" 3.90" 1.65" 40HA-209 3d" 4.20" 1.68" 40HA-210 4" 4.79" 1.73" 20

U.L. File No. E-1275 d" – 2”

®

®

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E19

Rigid/Intermediate Grade Conduit Fittings

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E19

Page 20: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E20 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Rigid/Intermediate Grade Conduit Fittings

Conduit Nipples – Die Cast Zinc 1" LongCat. Conduit Std.No. Size A B Ctn.

HA-211 d" 1" n" 1000HA-212 f" 1" 1i" 500HA-213 1" 1" 1k" 250

U.L. File No. E-1275 d" & f“ onlyB

A

A

B

f"

Offset Nipples – Die Cast ZincCat. Conduit Std.No. Size A B Ctn.

HO-221 d" 2.60" 1.00" 100HO-222 f" 2.62" 1.32" 100HO-223 1" 2.68" 1.51" 100HO-224 1b" 2.85" 1.85" 50HO-225 1d" 2.88" 2.08" 50HO-226 2" 3.19" 2.71" 20

f offset.U.L. File No. E-1275

Locknuts – Steel/Zinc PlatedCat. Conduit Dimensions (in.) Std.No. Size A (min.) B (max.) Ctn.

LN-100-SC c" – – 1000LN-101-SC d" 0.125" 1.140" 1000LN-102 f" 0.140" 1.420" 1000LN-103 1" 0.170" 1.770" 500LN-104 1b" 0.170" 2.281" 200LN-105 1d" 0.170" 2.598" 100LN-106 2" 0.187" 3.175" 50LN-107 2d" 0.375" 3.562" 30LN-108 3" 0.375" 4.250" 25LN-109 3d" 0.438" 4.803" 25LN-110 4" 0.438" 5.402" 25LN-111 5" 0.500" 6.674" 10LN-112 6" 0.561" 7.934" 10

U.L. File No. E-1275

Thin Construction Locknuts–Steel/Zinc PlatedCat. Conduit Unit Std.No. Size Qty. Ctn.

SPLN-107 2d" 30 30SPLN-108 3" 25 25SPLN-109 3d" 25 25SPLN-110 4" 25 25

*Not U.L. Listed

A

B

®

®

®

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E20

Page 21: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E21

Rigid/Intermediate Grade Conduit Fittings

Locknuts – Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Size A (min.) B (max.) Ctn.

LN-201 d" 0.125" 1.140" 2000LN-202 f" 0.140" 1.420" 1000LN-203 1" 0.170" 1.770" 1000LN-204 1b" 0.170" 2.281" 500LN-205 1d" 0.170" 2.598" 500LN-206 2" 0.187" 3.175" 200LN-207 2d" 0.375" 3.562" 100LN-208 3" 0.375" 4.250" 100LN-209 3d" 0.438" 4.803" 40LN-210 4" 0.438" 5.402" 40

CSA File No. LR-12798U.L. File No. E-1275

A

B

Locknuts–NonmetallicCat. Trade Std. No. Size “A” Dia. “B” Thd. Ctn.

LN-501 d" 1.3 d-14 100LN-502 f" 1.4 f-14 100LN-503 1" 1.7 1-11d 50

Material: Nylon 6/6Color: Gray

A

Grounding Locknuts – Malleable Iron/Zinc PlatedCat. Conduit Dimensions (in.) Std.No. Size A (min.) B (max.) Ctn.

LG-401 d" 0.125" 1.140" 100LG-402 f" 0.140" 1.420" 100LG-403 1" 0.170" 1.770" 50LG-404 1b" 0.170" 2.281" 50LG-405 1d" 0.170" 2.598" 50LG-406 2" 0.187" 3.175" 25LG-407 2d" 0.375" 3.562" 10LG-408 3" 0.375" 4.250" 10LG-409 3d" 0.438" 4.803" 50LG-410 4" 0.438" 5.402" 5

U.L. File No. E-1275

AB

Sealing Locknuts – Steel/Zinc PlatedCat. Conduit Dimensions (in.) Std.No. Size A (min.) B (max.) Ctn.

LS-101 d" 0.26" 1.12" 1000LS-102 f" 0.27" 1.37" 1000LS-103 1" 0.28" 1.75" 500LS-104 1b" 0.32" 2.06" 200LS-105 1d" 0.32" 2.37" 100LS-106 2" 0.32" 2.87" 50LS-107 2d" 0.32" 3.43" 50LS-108 3" 0.32" 4.12" 50LS-109 3d" 0.32" 4.62" 50LS-110 4" 0.32" 5.18" 25

U.L. File No. E-1275

A

B

®®

®®

®

®

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E21

Page 22: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E22 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Rigid/Intermediate Grade Conduit Fittings

Conduit Bushings Die Cast Zinc – Insulated MetallicCat. Conduit Std.No. Size A B Ctn.

BU-801 d" 1.06 0.43 1000BU-802 f" 1.31 0.43 1000BU-803 1" 1.59 0.48 500BU-804 1b" 1.96 0.56 250BU-805 1d" 2.18 0.60 250BU-806 2" 2.68 0.56 250BU-807 2d" 3.25 0.90 50BU-808 3" 3.87 0.85 25BU-809 3d" 4.37 0.93 25BU-810 4" 5.00 0.93 10

• 105°C thermoplastic liners.• Heavy reinforced ribs.

Conduit Bushings Die Cast Zinc – Heavy Reinforced RibsCat. Conduit Dimensions (in.) Std.No. Size A (min.) B (max.) Ctn.

BU-201 d" 1.05 0.37 1000BU-202 f" 1.32 0.37 1000BU-203 1" 1.58 0.47 500BU-204 1b" 1.94 0.50 250BU-205 1d" 2.20 0.52 250BU-206 2" 2.69 0.52 250BU-207 2d" 3.23 0.85 50BU-208 3" 3.84 0.85 25BU-209 3d" 4.35 0.85 25BU-210 4" 5.02 0.85 10

Insulated Bushings – ThermoplasticCat. Conduit Std.No. Size A B Ctn.

BU-501 d" u" 1h" 400BU-502 f" u" 1∫" 400BU-503 1" l" 1l" 200BU-504 1b" l" 1C" 100BU-505 1d" l" 2i" 100BU-506 2" e" 2W" 60BU-507 2d" z" 3i" 20BU-508 3" I" 3B" 20BU-509 3d" f" 4R" 5BU-510 4" A" 4B" 5BU-511 5" 1" 6j" 5BU-512 6" 1" 7k" 5

U.L. File No. E-1275 d"-4" onlyRated 105°C

A

B

®

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E22

Page 23: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E23

Rigid/Intermediate Grade Conduit Fittings

A

BBushings – Iron/Zinc Plated

Cat. Conduit Std.No. Size A B Ctn.

BU-401 d" 1o" k" 1000BU-402 f" 1b" k" 1000BU-403 1" 1l" d" 500BU-404 1b" 1n" w" 200BU-405 1d" 2$" l" 100BU-406 2" 2}" l" 50BU-407 2d" 3i" x" 30BU-408 3" 3e" A" 25BU-409 3d" 4h" B" 25BU-410 4" 4y" n" 25BU-411 5" 4y" n" 10

U.L. File No. E-1275

®

A

B

Insulated Bushings – Iron/Zinc PlatedCat. Conduit Std.No. Size A B Ctn.

BI-901 d" 1o" d" 1000BI-902 f" 1b" d" 1000BI-903 1" 1l" l" 500BI-904 1b" 1n" x" 200BI-905 1d" 2$" e" 100BI-906 2" 2}" e" 50BI-907 2d" 3r" I" 30BI-908 3" 3B" I" 25BI-909 3d" 4k" g" 25BI-910 4" 4O" 2s" 25

Grounding Bushings Die Cast Zinc – Insulated Metallic – With Aluminum Lay in Type Lug

Cat. Trade Grounding Lug Wire size Std.No. Size min. max Ctn.

BG-201 d" 14 4 500BG-202 f" 14 4 500BG-203 1" 14 4 250BG-204A 1b" 14 4 200BG-204 1b" 8 1/0 200BG-205A 1d" 11 4 100BG-205 1d" 8 1/0 50BG-206A 1" 14 4 100BG-206 2" 8 1/0 50BG-207 2d" 8 1/0 50BG-207A 2d" 6 250 MCM 50BG-208 3" 8 1/0 50BG-208A 3" 6 250 MCM 50BG-209 3d" 8 1/0 10BG-209A 3d" 6 250 MCM 10BG-210 4" 8 1/0 10BG-210A 4" 6 250 MCM 10

• 105°C Thermoplastic liners.• Heavy reinforced ribs.

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E23

Page 24: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E24 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Rigid/Intermediate Grade Conduit Fittings

Insulated Grounding Bushings – Malleable Iron/Zinc PlatedCat. Conduit Grounding Lug Std.No. Size Wire Capacity A B Ctn.

BG-801 d" 1o" d" 500BG-802 f" #14-#4 CU 1b" d" 500BG-803 1" or 1l" l" 250BG-804 1b" #12-#4 AL 1n" x" 150BG-805 1d" 2$" e" 150BG-806 2" 2}" e" 100BG-807 2d" #14-1/0 CU 3i" I" 60BG-808 3" or #12-1/0 AL 3e" I" 30BG-809 3d" #6-250 MCM 4h" g" 30BG-810 4" CU or AL 4y" 2s" 30

U.L. File No. E-19851d"-2" Iron2b"-4" Die Cast Zinc

Grounding Bushings Die Cast Zinc – Insulated Metallic With Aluminum Lug

Cat. Trade Grounding Lug Wire size Std.No. Size min. max Ctn.

BG-801A d" 14 6 500BG-802A f" 14 6 500BG-803A 1" 14 6 250BG-804A 1b" 14 2 200BG- 805A 1d" 14 2 100BG-806A 2" 14 2 100BG-807A 2d" 14 2/0 50BG-808A 3" 14 2/0 50BG-809A 3d" 14 2/0 10BG-810A 4" 14 2/0 10BG-810B 4" 6 250 MCM 10

U.L. File No. E-19851

• For copper or aluminum bare ground wire.• 105°C thermoplastic liners.• Heavy reinforced ribs.

• RB-121 thru RB-165 – Steel.• RB-175 thru RB-187 – Malleable Iron

(concrete tight)/ Zinc Plated.

B

A

Reducing BushingsCat. Conduit Std.No. Size A B Ctn.

RB-121 f"-d" l" g" 100RB-131 1"-d" e" 1a" 50RB-132 1"-f" e" 1a" 50RB-141 1b"-d" W" 1k" 50RB-142 1b"-f" W" 1k" 50RB-143 1b"-1" W" 1k" 50RB-151 1d"-d" z" 1W" 50RB-152 1d"-f" z" 1W" 50RB-153 1d"-1" z" 1W" 50RB-154 1d"-1b" z" 1W" 50RB-161 2"-d" B" 2p" 25RB-162 2"-f" B" 2p" 25RB-163 2"-1" B" 2p" 25RB-164 2"-1b" B" 2p" 25RB-165 2"-1d" B" 2p" 25RB-175 2d"-1d" g" 2m" 25RB-176 2d"-2" g" 2m" 25RB-186 3"-2" C" 2k" 25RB-187 3"-2d" C" 2k" 25

U.L. File No. E-1275

®

®

®

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E24

Page 25: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E25

Rigid/Intermediate Grade Conduit Fittings

Reducers and Enlargers – Malleable Iron/Zinc PlatedCat. Conduit Std.No. Size A B Ctn.

RB-421 f"-d" e" 1i" 100RB-432 d"-f" 1 1i" 100RB-443 1"-f" L" 1i" 50

U.L. File No. E-1275

B

B

A

Reducing Washers – Steel/Zinc PlatedCat. Conduit Diameter Std.No. Size A B C Ctn.

WA-110 d"-c" 1i" W" B" 500WA-121 f"-d" 1d" g" 1h" 500WA-131 1"-d" 1f" g" 1j" 500WA-132 1"-f" 1f" 1p" 1j" 500WA-141 1b"-d" 2i" g" 1W" 200WA-142 1b"-f" 2i" 1p" 1W" 200WA-143 1b"-1" 2i" 1R" 1W" 200WA-151 1d"-d" 2e" g" 1g" 200WA-152 1d"-f" 2e" 1p" 1g" 200WA-153 1d"-1" 2e" 1R" 1g" 200WA-154 1d"-1b" 2e" 1z" 1g" 200WA-161 2"-d" 3b" g" 2c" 100WA-162 2"-f" 3b" 1p" 2c" 100WA-163 2"-1" 3b" 1R" 2c" 100WA-164 2"-1b" 3b" 1z" 2c" 100WA-165 2"-1d" 3b" 1O" 2c" 100WA-171 2d"-d" 3b" g" 2g" 100WA-172 2d"-f" 3b" 1p" 2g" 100WA-173 2d"-1" 3b" 1R" 2g" 100WA-174 2d"-1b" 3b" 1z" 2g" 100WA-175 2d"-1d" 3b" 1O" 2g" 100WA-176 2d"-2" 3b" 2k" 2g" 100WA-181 3"-d" 4d" g" 3d" 100WA-182 3"-f" 4d" 1z" 3d" 100WA-183 3"-1" 4d" 1R" 3d" 100WA-184 3"-1b" 4d" 1z" 3d" 100WA-185 3"-1d" 4d" 1O" 3d" 100WA-186 3"-2" 4d" 2k" 3d" 100WA-187 3"-2d" 4d" 2j" 3d" 100

WA-121 thru WA-165 CSA listed.

A

B

C

®

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E25

Page 26: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E26 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Rigid/Intermediate Grade Conduit Fittings

One Hole Straps – Steel/Zinc PlatedCat. Screw Conduit Std.No. Size Size A B Ctn.

HS-100-SC 10 c" f" 1I" 1000HS-101 b d" 1" 1n" 500HS-102 b f" 1" 2Z" 500HS-103 b 1" 1" 2u" 250HS-104 j 1b" 1" 3p" 100HS-105 c 1d" 1i" 3u" 100HS-106 c 2" 1i" 3B" 100HS-107 k 2d" 1b" 5h" 25HS-108 d 3" 1c" 5g 25HS-109 d 3d" 1c" 6b" 10HS-110 d 4" 1c" 6g" 10

Pipe Straps – Malleable Iron/Zinc PlatedCat. Screw Conduit Std.No. Size Size A B Ctn.

HS-400 10 c" 1W" w" 500HS-401 b d" 2D" e" 500HS-402 b f" 2k" m" 500HS-403 b 1" 2g" n" 100HS-404-SC j 1b" 3j" 1o" 100HS-405 c 1d" 3f" 1a" 50HS-406 d 2" 4x" 1j" 25HS-407 e 2d" 5W" 1e" 25HS-408 e 3" 6g" 1g" 25HS-409 e 3d" 7z" 2a" 10HS-410 e 4" 8l" 2c" 10HS-411 e 5" 10s" 2e" 5

Two Hole Strap – Steel/Zinc PlatedCat. Screw Conduit Std.No. Size Size A B C Ctn.

HS-901 8 d" f" 2k" i" 1200HS-902 10 f" f" 2W" i" 900HS-903 b 1" f" 3k" i" 600HS-904 b 1b" f" 3B" i" 450HS-905 b 1d" f" 4h" i" 50HS-906 b 2" f" 4k" i" 150HS-907 b 2d" 1" 5a" b" 150HS-908 d 3" 1" 6i" b" 60HS-909 b 3d" 1" 7i" b" 60HS-910 b 4" 1" 8W" b" 60

CSA Certified

Nail Strap – Stamped Steel/Zinc PlatedCat. Rigid/MC EMT Flex Std.No. Size Size Size A B Ctn.

N-101-SC – d" c" 2q" 1Z" 1000N-102-SC d" f" d" 2j" 1r" 1000N-103-SC f" 1" – 2c" 1v" 1000

B

A

®

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E26

Page 27: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E27

Rigid/Intermediate Grade Conduit Fittings

Flange Plates – Malleable Iron/Zinc PlatedCat. Conduit Dia. Depth Std.No. Size A B Ctn.

FP-401 d" 3" .625 50FP-402 f" 3c" .656 50FP-403 1" 3e" .765 50FP-404 1b" 4" .875 25FP-405 1d" 4c" .937 25FP-406 2" 4g" .843 25

A

B

j

Bolt Hole

A

B

A

B

Pipe Spacers for Rigid/Intermediate or Thinwall – Die Cast ZincCat. Conduit Std.No. Size A B Ctn.

CB-201 d" 2" 1" 1000CB-202 f" 2c" 1h" 500CB-203 1" 2f" 1j" 500CB-204 1b" 3c" 1d" 250CB-205 1d" 3m" 1e" 100CB-206 2" 4d" 2" 50

Rigid/Intermediate Space Caps – PlasticCat. Conduit Std.No. Size A B Ctn.

BR-501 d" 2v" 1y" 100BR-502 f" 2v" 1U" 100BR-503 1" 2v" 2a" 100BR-504 1b" 2v" 2V" 100BR-505 1d" 2v" 3$" 100

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E27

Page 28: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E28 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

• Die cast copper free aluminum construction.• Provide access for pulling, splicing, and

maintenance.• For rigid conduit/IMC applications.• U.L. Listed.• Fittings, covers and gaskets are

interchangeable with those produced byother leading manufacturers.

• Finish: Powder Coated Urethane.

TYPE ALR

Conduit Bodies, Covers and Gaskets – LR StyleCat. Trade Std.No. Size A B Ctn.

ALR-1 d" 3g 2 50ALR-2 f" 4e 2j 50ALR-3 1" 5c 2d 25ALR-4 1b" 7b 3c 10ALR-5 1d" 7b 3c 10ALR-6 2" 9d 3n 5ALR-7* 2d" 12b 5d 1ALR-8* 3" 12b 5d 1ALR-9* 3d" 15 6d 1ALR-10* 4" 15 6d 1

* Shipped with cover. Price includes cost of cover and body.

• Die cast copper free aluminum construction.• Provide access for pulling, splicing, and

maintenance.• For rigid conduit/IMC applications.• U.L. Listed.• Fittings, covers and gaskets are

interchangeable with those produced by otherleading manufacturers.

• Finish: Powder Coated Urethane.

TYPE ALL

Conduit Bodies, Covers and Gaskets – LL StyleCat. Trade Std.No. Size A B Ctn.

ALL-1 d" 3g 2 50ALL-2 f" 4e 2j 50ALL-3 1" 5c 2d 25ALL-4 1b" 7b 3c 10ALL-5 1d" 7b 3c 10ALL-6 2" 9d 3n 5ALL-7* 2d" 12b 5d 1ALL-8* 3" 12b 5d 1ALL-9* 3d" 15 6d 1ALL-10* 4" 15 6d 1

* Shipped with cover. Price includes cost of cover and body.

Rigid/Aluminum Conduit Bodies, Gaskets and Covers

Conduit Bodies, Covers and Gaskets – C StyleCat. Trade Std.No. Size A B Ctn.

AC-1 d" 3g 1Q 50AC-2 f" 4e 1w 50AC-3 1" 5c 1f 25AC-4 1b" 7b 2d 10AC-5 1d" 7b 2d 10AC-6 2" 9d 3a 5AC-7* 2d" 12b 4d 1AC-8* 3" 12b 4d 1AC-9* 3d" 15 5d 1AC-10* 4" 15 5d 1

* Shipped with cover. Price includes cost of cover and body.

TYPE AC

®

®

®

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E28

Page 29: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E29

Rigid/Aluminum Conduit Bodies, Gaskets and Covers

Conduit Bodies, Covers and Gaskets – LB StyleCat. Trade Std.No. Size A B Ctn.

ALB-1 d" 3g 2h 50ALB-2 f" 4e 2k 50ALB-3 1" 5c 2f 25ALB-4 1b" 7b 3l 10ALB-5 1d" 7b 3m 10ALB-6 2" 9d 4d 5ALB-7* 2d" 12b 5b 1ALB-8* 3" 12b 5g 1ALB-9* 3d" 15 6n 1ALB-10* 4" 15 6n 1

* Shipped with cover. Price includes cost of cover and body.

TYPE ALB

TYPE AT

Conduit Bodies, Covers and Gaskets – C StyleCat. Trade Std.No. Size A B Ctn.

AT-1 d" 3g 2h 50AT-2 f" 4e 2X 50AT-3 1" 5c 2e 25AT-4 1b" 7b 3w 10AT-5 1d" 7b 3w 10AT-6 2" 9d 4 5AT-7* 2d" 12b 5A 1AT-8* 3" 12b 5A 1AT-9* 3d" 15 6m 1AT-10* 4" 15 6m 1

* Shipped with cover. Price includes cost of cover and body.

Conduit Bodies, Covers and Gaskets – LR StyleCat. Trade Std.No. Size A B Ctn.

ALRL-1 d" 3g 2 50ALRL-2 f" 4e 2j 50ALRL-3 1" 5c 2d 25ALRL-4 1b" 7b 3c 10ALRL-5 1d" 7b 3c 10ALRL-6 2" 9d 3n 5

* Shipped with cover. Price includes cost of cover and body.

TYPE ALRL

®

®

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E29

Page 30: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E30 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Aluminum Conduit Bodies, Gaskets and Covers

Fiber Gasket

Neoprene Gasket

• Stamped aluminum (1⁄2" thru 2" sizes) ordie cast aluminum (21⁄2" thru 4" sizes).

• Steel zinc plated screws.

• Fiber or neoprene material

Aluminum covers with Stainless Steel ScrewsCat. Conduit Std.No. Size Ctn.

CV-1 d" 250CV-2 f" 250CV-3 1" 250CV-4 1b" - 1d" 50CV-5 2" 25CV-6 2d" - 3" 5CV-7 3d" - 4" 5

SCV-1 d" 250SCV-2 f" 250SCV-3 1" 250SCV-4 1b" - 1d" 250SCV-5 2" 100

Gaskets – CompositionCat. Conduit Std.No. Size Ctn.

GKV-1 d" 100GKV-2 f" 50GKV-3 1" 25GKV-4 1b" - 1d" 25GKV-5 2" 25GKV-6 2d" - 3" 5GKV-7 3d" - 4" 5

Gaskets – NeopreneCat. Conduit Std.No. Size Ctn.

GKN-1 d" 100GKN-2 f" 50GKN-3 1" 25GKN-4 1b" - 1d" 25GKN-5 2" 25GKN-6 2d" - 3" 5GKN-7 3d" - 4" 5

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E30

Page 31: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E31

Flexible Cord & Power Cable Connectors

LR 52391

StraightTrade Throat Hex

Cat. or Hub Cord Size Flat A B C Std.No. Size Range ± .03 ± .06 Max. ± .06 ± .06 Ctn.

2671† c" .125-.275 0.33 .78 2.0 .90 .46 2502690† d" .125-.275 0.33 1.00 2.3 .90 .60 1002672 d" .250-.400 0.55 1.08 2.6 1.27 .60 1002673* d" .400-.560 0.55 1.08 2.6 1.27 .60 1002691* d" .560-.690 0.54 1.32 3.0 1.57 .60 1002692* d" .660-.780 0.54 1.32 3.0 1.57 .60 1002693 f" .250-.400 0.55 1.22 2.7 1.27 .62 1002694* f" .400-.560 0.55 1.22 2.7 1.27 .62 1002674 f" .560-.690 0.79 1.34 3.0 1.57 .62 1002675 f" .660-.780 0.79 1.34 3.0 1.57 .62 1002696* f" .770-.895 0.76 1.64 3.2 1.89 .62 1002697 1" .250-.400 0.54 1.50 2.9 1.27 .77 -2698* 1" .400-.560 0.54 1.50 2.9 1.27 .77 1002695 1" .560-.690 0.98 1.60 3.1 1.89 .77 1002676 1" .660-.780 0.98 1.60 3.3 1.89 .77 1002677 1" .770-.895 0.98 1.60 3.3 1.89 .77 1002678 1" .870-1.020 0.98 1.60 3.3 1.89 .77 502699 1" .890-1.090 0.98 2.25 4.2 2.58 .77 102700 1" 1.080-1.280 0.98 2.25 4.0 2.58 .77 502702 1b" .890-1.090 1.25 2.25 4.2 2.58 .80 102703* 1b" 1.080-1.280 1.25 2.25 4.0 2.58 .80 102704* 1b" 1.270-1.470 1.25 2.25 4.0 2.58 .80 102705-TB 1b" .890-1.150 1.47 2.65 4.2 2.95 .82 102706 1b" 1.140-1.400 1.47 2.65 4.3 2.95 .82 102707* 1b" 1.390-1.650 1.47 2.65 4.3 2.95 .82 102708 2" 1.190-1.530 1.89 3.13 5.1 3.50 .84 52709 2" 1.520-1.860 1.89 3.13 4.9 3.50 .84 52710* 2" 1.850-2.190 1.89 3.13 4.9 3.50 .84 5

*Remove sufficient outer covering of cable to permit conductors to pass thru connector body.†CSA certified for factory installation.Material: Weather Stabilized Nylon, Rated at – 34°C to 105°C Temperature. For 90° Style See AS-72555.

E 13938

The BLACK BEAUTY ™ Nonmetallic Liquidtight Strain Relief Connectors

90 Degree AngleTrade

Cat. or Hub Cord Throat Hex Std.No. Size Range Size Flat A B C D Ctn.

2680† c" .125-.275 .33 .62 1.8 .90 .46 1.00 1002681 d" .250-.400 .55 .83 2.5 1.27 .60 1.35 502682* d" .400-.560 .55 .83 2.5 1.27 .60 1.35 502683 f" .560-.690 .78 1.06 2.8 1.57 .62 1.60 502684 f" .660-.780 .78 1.06 2.8 1.57 .62 1.60 502688 1" .560-.690 1.00 1.280 3.0 1.89 .77 1.90 252685 1" .660-.780 1.00 1.280 3.0 1.89 .77 1.90 252686 1" .770-.895 100 1.280 3.0 1.89 .77 1.90 252687* 1" .870-1.020 1.00 1.280 3.0 1.89 .77 1.90 25

*Remove sufficient outer covering of cable to permit conductors to pass thru connector body.†CSA certified for factory installation.

• Installs on cord by hand.• Achieves maximum pullout strength

without installation tools.• Each hub size takes a range of cord

diameters.

• Non metallic construction providescorrosion resistance.

• Weathers stabilized nylon rated at–34°C to +105°C temperature.

®

®

®

®

LR 52391E 13938®

®

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E31

Page 32: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E32 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Liquidtight Flexible Nonmetallic Conduit Connectors and Tubing

A

B*

D

F*

C

Standard Material/Finish• Body/Gland–Nylon-Grey• “O” Ring–Nitrate (Black)• Locknut–Nylon• Temp. Rating–80°C• Material Flammability Rating: UL94-V2

Listed/Certified by:• U.L. Listed (File # E23018)• C.S.A. (File # LR52391)

Conforms To:• Watertight requirements for Type 4

45° Connectors – Liquidtight Flex for Nonmetallic ConduitC ±.015 (0.40) Min.

A± .015 B* ±.35 Across Throat E FCat. Trade (0.40) Inch (0.90) Inch Corners Dia. D. Thread Inch (mm) Std.No. Size (mm) (mm) Inch (mm) Inch (mm) NPT. Approx. Ctn.

LT-540 c" (14.48) 2.012 (51.10) (34.39) (10.59) d-14 1.534 (38.95) 50LT-541 d" (14.48) 2.092 (53.14) (36.78) (13.97) d-14 1.590 (40.39) 50LT-542 f" (14.78) 2.452 (62.28) (44.20) (18.80) f-14 1.821 (46.25) 50LT-543 1" (18.44) 2.684 (68.17) (52.53) (23.88) 1-11/12 2.034 (51.66) 25

Connectors – Liquidtight Flex for Nonmetallic ConduitC ±.015 (0.40) Min.

A± .015 B* ±.35 Across Throat E FCat. Trade (0.40) Inch (0.90) Inch Corners Dia. D. Thread Inch (mm) Std.No. Size (mm) (mm) Inch (mm) Inch (mm) NPT. Approx. Ctn.

LT-500 c" .570 1.595 (40.51) 1.354 .417 d-14 1.880 (47.75) 100LT-501 d" .570 1.636 (41.55) 1.448 .550 d-14 1.986 (50.44) 100LT-502 f" .582 1.757 (44.63) 1.740 .740 f-14 2.212 (56.18) 50LT-503 1" .726 1.923 (48.84) 2.068 .940 1-11/12 2.508 (63.70) 50

90° Connectors – Liquidtight Flex for Nonmetallic ConduitC ±.015 (0.40) Min.

A± .015 B* ±.35 Across Throat E FCat. Trade (0.40) Inch (0.90) Inch Corners Dia. D. Thread Inch (mm) Std.No. Size (mm) (mm) Inch (mm) Inch (mm) NPT. Approx. Ctn.

LT-590 c" (14.48) 1.380 (35.05) (34.39) (10.59) d-14 1.880 (47.75) 50LT-591 d" (14.48) 1.489 (37.82) (36.78) (13.97) d-14 1.986 (50.44) 50LT-592 f" (14.78) 1.790 (45.47) (44.20) (18.80) f-14 2.212 (56.18) 50LT-593 1" (18.44) 2.104 (53.44) (52.53) (23.88) 1-11/12 2.508 (63.70) 25

®®

®®

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E32

Page 33: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

Liquidtight Flexible Nonmetallic Conduit (Type B) Outdoor XTRAFLEX® Raceway System

Cat. No. Trade I.D. IN. O.D.IN. Std.Series Size Min. Max. Min. Max. Ctn.

LTC038GY c" .484 .504 .690 .710 100LTC050GY d" .622 .642 .820 .840 100LTC075GY f" .820 .840 1.030 1.050 100LTC100GY 1" 1.041 1.066 1.290 1.315 100LTC125GY 1b" 1.380 1.410 1.630 1.660 100LTC150GY 1d" 1.575 1.600 1.865 1.900 50LTC200GY 2" 2.020 2.045 2.340 2.375 50

Color: GrayLength: 100 ft. for LTC038GY thru LTC125GY 50 ft. for LTC150GY and LTC200GYU.L. Listed: File E95745U.L. Temperature Rating: 80°C dry, 60°C wet, 70°C oil. res. sunlight resistant, outdoor, direct burial.CSA Certified: File LR 80349-2CSA Temperature Rating: 75°C to-18°CFor use with Thomas & Betts LT38P, LT38M, LT500 series and Liquidtight Flexible Metal Conduit Fittings.Material: PVC Helix reinforcement surrounded with flexible PVC.Voltage Rating: 600V

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E33

Liquidtight Flexible Nonmetallic Conduit Connectors and Tubing

Conduit Cutter – For Nonmetallic Flexible ConduitCat.No. Description

XF-CUT For cutting NM flexible conduit up to 1"XF-BLADE Replacement blade for XF-CUT

Liquidtight Whip AssemblyCat. Conduit Wire Std.No. Size Length Gauge Ctn.

LTWHIP 12-6-10 d" 6' #10 6LTWHIP 12-4-10 d" 4' #10 6LTWHIP 34-6-8 f" 6' #8 6LTWHIP 34-4-8 f" 4' #8 6Whip with metallic fittings – one straight, one 90°

LTWM 12-6-10 d" 6' #10 6LTWM 12-4-10 d" 4' #10 6LTWM 34-6-8 f" 6' #8 6LTWM 34-4-8 f" 4' #8 6

®®

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E33

Page 34: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E34 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Liquidtight Fittings

Versa Ground™ LIquidtight Fittings – 90° TypeCat. Trade Std.No. Size A B C Ctn.

5351GR c 1c" 1b" 14-4 505352GR d 1l" 1k" 14-4 505353GR f 1f" 1m" 14-4 505354GR 1 2i" 2h" 14-4 25

5251GR c 1c" 1b" 14-4 505252GR d 1l" 1k" 14-4 505253GR f 1f" 1m" 14-4 505254GR 1 2i" 2h" 14-4 255251ALGR c 1c" 1b" 14-4 505252ALGR d 1l" 1k" 14-4 505253ALGR f 1f" 1m" 14-4 505254ALGR 1 2i" 2h" 14-4 25

A

B

LUG RANGE

B LUG RANGE

A

C

Versa Ground™ LIquidtight FittingsCat. Trade Std.No. Size A B C Ctn.

5341GR c 1l" 14-4 1h" 505342GR d 1g" 14-4 1c" 505343GR f 2a" 14-4 1i" 505344GR 1 2b" 14-4 1f" 25

5241GR c 1l" 14-4 1h" 505242GR d 1g" 14-4 1c" 505243GR f 2a" 14-4 1i" 505244GR 1 2b" 14-4 1f" 25

Liquidtight to Rigid External Ground AdapterCat. Trade Std.No. Size A B Ctn.

5271GR c 1q" 14-4 505272GR d 1c 14-4 505273GR f 1y" 14-4 505274GR 1 1g" 14-4 25

B LUG RANGE

A

A

UG RANGE Versa Ground™ LIquidtight FittingsCat. Trade Std.No. Size A B Ctn.

5331GR c 1d" 14-4 1005332GR d 1l" 14-4 1005333GR f 1e" 14-4 255334GR 1 2h" 14-4 50

5231GR c 1d" 14-4 1005232GR d 1l" 14-4 1005233GR f 1e" 14-4 255234GR 1 2h" 14-4 505231ALGR c 1d" 14-4 1005232ALGR d 1l" 14-4 1005233ALGR f 1e" 14-4 505234ALGR 1 2h" 14-4 50

B LUG RANGE

C LUG RANGE

B LUG RANGE

B LUG RANGE

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E34

Page 35: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

Straight ConnectorsCat. Conduit Diameter Std.No. Size A B C Ctn.

LT-700 c" 1h" d" 1C" 100LT-701 d" 1i" T" 1O" 100LT-702 f" 1k" l" 2a" 50LT-703 1" 1f" e" 2c" 50LT-704 1b" 2k" L" 2L 25LT-705 1d" 2f" A" 2g" 10LT-706 2" 3w" A" 3j" 5

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E35

Liquidtight Flexible Metal Conduit Connectors

• 3⁄8"-1" – Steel.• 11⁄4"-2" – Malleable Iron/Zinc Plated.

• 3⁄8"-1" – Steel.• 11⁄4"-2" – Malleable Iron/Zinc Plated (with

insulated throat).

Straight ConnectorsCat. Conduit Diameter Std.No. Size A B C Ctn.

LT-100 c" 1h" d" 1m" 100LT-101 d" 1i" T" 1g" 100LT-102 f" 1k l" 2o" 50LT-103 1" 1f" e" 2s" 50LT-104 1b" 2k" L" 2x" 25LT-105 1d" 2f" A" 2A" 10LT-106 2" 3w" A" 3r" 5

CSA File No. LR-12798U.L. File No. E-1275 -c"-4"

45° Connectors – Malleable Iron/Zinc Plated (with insulated throat)

Cat. Conduit Dimensions Std.No. Size E F G I Ctn.

LT-950 c" 1h" d" 1l" 1h" 50LT-951 d" 1i" d" 1e" 1p" 50LT-952 f" 1k" l" 1g" 1i" 50LT-953 1" 1f" e" 2a" 1c" 25

45° Connectors – Malleable Iron/Zinc PlatedCat. Conduit Dimensions Std.No. Size E F G H Ctn.

LT-450 c" 1h" d" 1l" O" 50LT-451 d" 1i" d" 1e" 1" 50LT-452 f" 1k" l" 1g" 1p" 50LT-453 1" 1f" e" 2a" 1s" 25

CSA File No. LR-12798U.L. File No. E-1275

®®

®®

®®

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E35

Page 36: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E36 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Liguidtight Flexible Metal Conduit Connectors

90° Connectors – Malleable Iron/Zinc PlatedCat. Conduit Dimensions Std.No. Size J K L M Ctn.

LT-490 c" 1h" d" 1g" 1c" 50LT-491 d" 1i" d" 2" 1u" 50LT-492 f" 1k" l" 2i" 1y" 50LT-493 1" 1f" e" 2l" 1g" 25

CSA File No. LR-12798U.L. File No. E-1275

90° Connectors – Malleable Iron/Zinc Plated (with insulated throat)

Cat. Conduit Dimensions Std.No. Size J K L N Ctn.

LT-990 c" 1h" d" 1g" 1v" 50LT-991 d" 1i" d" 2" 1d" 50LT-992 f 1k" l" 2i" 1f" 50LT-993 1" 1f" e" 2i" 1O" 25

Straight Connectors – Die-Cast ZincCat. Conduit Diameter Std.No. Size A B C Ctn.

LT-200 c" 1.81" 0.50" 1.06" 100LT-201 d" 1.88" 0.61" 1.19" 200LT-202 f" 2.03" 0.56" 1.44" 100LT-203 1" 2.28" 0.63" 1.75" 50LT-205 1d" 2.78" 0.78" 2.75" 20LT-206 2" 3.22" 0.78" 3.53" 20LT-207 2d" 3.53" 0.84" 4.28" 1LT-208 3" 3.91" 0.88" 4.72" 1LT-209 3d" 4.04" 0.91" 5.42" 1LT-210 4" 4.16" 0.94" 5.91" 1

U.L. File No. E-1275

Straight Connectors – Die Cast Zinc (with insulated throat)Cat. Conduit Diameter Std.No. Size A B C Ctn.

LT-800 c" 1I" E" 1x" 100LT-801 d" 1I" E" 1x" 100LT-802 f" 2D" E" 1c" 100LT-803 1" 2F" H" 1G" 50

CSA File No. LR-12798

®®

®

®

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E36

Page 37: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E37

Liquidtight Flexible Metal Conduit Connectors

90° Connectors – Die-Cast ZincCat. Conduit Diameter Std.No. Size A B C Ctn.

LT-290 c" 1.88" 1.38" 0.50" 100LT-291 d" 2.00" 1.41" 0.50" 100LT-292 f" 2.19" 1.66" 0.56" 100LT-293 1" 2.56" 1.88" 0.63" 50LT-294 1b" 3.00" 2.00" 0.69" 40LT-295 1d" 3.38" 2.56" 0.78" 20LT-296 2" 4.06" 3.00" 0.78" 10

U.L. File No. E-1275

90° Connectors – Die-Cast Zinc (with insulated throat)Cat. Conduit Diameter Std.No. Size A B C Ctn.

LT-890 c" 1.88" 1.38" 0.50" 100LT-891 d" 2.00" 1.41" 0.50" 100LT-892 f" 2.19" 1.66" 0.56" 100LT-893 1" 2.56" 1.88" 0.63" 50

Sealing “O” RingsCat. Std.No. Conduit Size Ctn.

SR-101 d" 500SR-102 f" 500SR-103 1" 500SR-104 1b" 250SR-105 1d" 250SR-106 2" 250

Material: Neoprene

®

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E37

Page 38: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E38 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Nonmetallic Sheathed Cable and Flexible Cord Connectors

All Plastic Connector for NM Cable and Flexible CordF

Cat. Size K.O. Max. Thk. Std. No. Range Size Fig. A B C D E Enclosure H Ctn.

3300 For use with 10-2, 12-2 and d" 2 1o n c .880 .795 .080 j x l 50014-2 NM cables; 18-2 and 18-3 SJ and SJO cords and 18-2 SV, SVO, SJT and SJTO cords, single or multiple; cord capacity .125-.300 diameter

3201 For use with 10-3, 12-3, 14-3, d" 1 1X 1 k .880 .795 .080 y dia. 50010-2, 12-2, 4-2 NM cables; multiple (2) 12-2 and 14-2 NM cables; single and multiple flexible cords in wire range .300 in. to .600 in.

3202 For use with 8-3 and 6-3 NM f" 1 1d 1j k 1.100 1.005 .090 g dia. 250cables; (2) 14-3, 14-2, 12-2 and 10-2 NM cables; single and multiple flexible cords in wire range .500 in. to .850 in.

Temperature Rating: 105°CCSA File Nos. 584 and 2884U.L. File No. E-23017

Figure 1 Figure 2

HHoleSize

HHoleSize

• High impact thermoplastic. U.L. 94-V1.• Features push-in design .• Captive locking wedge secures cable with single

squeeze of standard electrician’s pliers.• Provides excellent insulation, strain-relief and

high pull-out value.

Snap captive locking wedge into connector’s cavity.

Press locking wedge into cavity which locks onto cable.

Cat. No. 3201 is ideal for multiple flexible cordsand cable.

®®

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E38

Page 39: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

Clamp Type Connector – Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Size A (min.) A (max.) B Ctn.

NC-301 c" (d"KO) 0.18" 0.64" 1.16" 1000NC-302 f" 0.41" 0.82" 1.87" 500NC-303 1" 0.34" 0.94" 2.01" 250

CSA File No. LR-12798U.L. File No. E-17583

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E39

Nonmetallic Sheathed Cable Fittings

Hit Lock ConnectorsCat. Std.No. Description Ctn.

NC501-SC d” Hit Lock Connector 500NC501DBL-SC d” Double Hit Lock Connector 500NC502-SC f" Hit Lock Connector 100SB1216-SC Twist It Bushing For Metal Studs 50

.400

.580

1.030

1.2501.000

1.120

1.300

.580

2.485

1.315

.115

NC501-SC

NC501DBL-SC NC502-SC SB1216-SC

NM Clamp Type Connector – Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Size A (min.) A (max.) B Ctn.

NC-201 c" 0.40" 0.95" 1.87" 250NC-202 f" 0.50" 1.10" 1.84" 200NC-203 1" 0.62" 1.14" 2.00" 100NC-204 1b" 0.50" 1.38" 2.28" 100NC-205 1c" 0.75" 1.61" 2.49" 50NC-206 2" 0.90" 2.04" 3.35" 50

CSA File No. LR-12798U.L. File No. E-17583

®®

®®

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E39

Page 40: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E40 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Nonmetallic Sheathed Cable Fittings

Connectors Clamp Type, Non-Watertight – Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Size A (min.) A (max.) B Ctn.

NC-041 1b" 0.27" 0.75" 2.02" 100NC-051 1d" 0.54" 0.95" 2.50" 50NC-061 2" 0.75" 1.12" 3.41" 40

U.L. File No. E-15170-1b"-1d"U.L. File No. E-17583-2"

Duplex Clamp Type Connector – Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Size A (min.) A (max.) B Ctn.

XC-210 c" (d" KO) 0.13" 0.65" 1.56" 250XC-211-SC c" 0.24" 0.63" 1.59" 200XC-222-SC c" 0.24" 0.63" 1.59" 200

Conduit/Cable FMC AC MCC MCI NM

MAX. SIZE c" 10/2 .565 .565 10/2MIN. SIZE c" 14/2 .425 .425 14/2

CSA File No. LR-12798U.L. File No. E-17909

For use with aluminum smooth extrudedmetal clad cable. (min. dia. .410) –(max. dia. .500)

1-1h"

NM Saddle Type Connectors – Die Cast ZincCat. Dimensions (in.) Std.No. Size A (min.) A (max.) Ctn.

XC-2200-C c" 0.12" 0.63" 500

A max.A min.

Tilt In Connector Metallic Steel – Electro-GalvanizedCat. Conduit Std.No. Size A B C D E Ctn.

NC-850 d" .050 .950 1.312 .650 8-32 x f 1000NC-851 f"-1 .050 1.250 1.750 .760 8-32 x 1 500NC-852 1-b" .062 1.625 2.125 .760 10-32 x 1 250NC-853 1-d" .062 1.970 2.500 .785 10-32 x 12 100

®

®®

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E40

Page 41: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E41

Armored Cable/Flexible Metallic Conduit Fittings

Straight Connectors

Straight Squeeze Type Connectors–Malleable Iron or Stamped Steel / Zinc Plated

Cat. Conduit Unit Std.No. Size Qty. Ctn.

XC-400 c" (d" K.O.) 50 100XC-401 d" 25 100XC-402 f" 25 100XC-403 1" 25 100XC-404 1b" 5 10XC-405 1d" 10 10XC-406 2" 10 10XC-407 2d" 5 5XC-408 3" 5 5

UL File No. E-17909 d"-f"UL File No. E-1275 1"-3"c"-f"-STEEL

Straight Squeeze Type Connectors–Insulated Malleable Iron or Stamped Steel / Zinc Plated

Cat. Conduit Unit Std.No. Size Qty. Ctn.

XC-901 d" 25 100XC-902 f" 25 100XC-903 1" 25 100XC-904 1b" 5 10XC-905 1d" 10 10XC-906 2" 10 10XC-907 2d" 5 5XC-908 3" 5 5

d"-f"-STEEL

Clamp Straight Set, 90°, and Duplex Connectors

90° Angle Squeeze Type Connectors–Steel or Malleable Iron / Zinc Plated

Cat. Conduit Unit Std.No. Size Qty. Ctn.

XC-490 c" (d" K.O.) 50 100XC-491 d" 25 100XC-492 f" 25 50XC-493 1" 25 25XC-494 1b" 10 10XC-495 1d" 10 10XC-496 2" 5 5XC-497 2d" 1 1XC-498 3" 1 1

For die cast armored cable/flexible metallic conduit fittings and combination fittings refer to the Steel City® Die CastConduit Fittings section.UL File No. E-17909 c" & f"UL File No. E-1275 1"-3"c"-f"-STEEL

®

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E41

Page 42: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E42 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Armored Cable/Flexible Metallic Conduit Fittings

Straight Squeeze Type Connectors – Die Cast ZincCat. Dimensions (in.) Std.No. Fig. Size A (min.) A (max.) B Ctn.

XC-269 1 c" (d" KO) 0.45" 0.60" 0.96" 500XC-270 1 d" 0.74" 0.92" 1.43" 250XC-272 1 f" 0.88" 1.10" 1.59" 250XC-273 2 1" 1.10" 1.35" 1.60" 100XC-274 2 1b" 1.48" 1.65" 1.91" 100XC-275 2 1d" 1.68" 2.00" 2.12" 50XC-276 3 2" 2.12" 2.47" 2.54" 40XC-277 3 2d" 2.71" 3.08" 2.88" 10XC-278 3 3" 3.15" 3.60" 3.88" 5XC-278A 3 3d" 3.20" 4.03" 5.04" 1XC-2710 3 4" 3.15" 4.25" 5.04" 1

U.L. File No. E-17909 c" & 1"U.L. File No. E-1275 1b"-2"CSA File No. LR-12798 c"-1"

®®

Straight Squeeze Type Connectors – Insulated Die Cast ZincCat. Dimensions (in.) Std.No. Fig. Size A (min.) A (max.) B Ctn.

XC-870 1 d" 0.74" 0.92" 1.43" 250XC-872 1 f" 0.88" 1.10" 1.59" 250XC-873 2 1" 1.10" 1.35" 1.60" 100XC-874 2 1b" 1.48" 1.65" 1.91" 50XC-875 2 1d" 1.68" 2.00" 2.12" 50XC-876 3 2" 2.12" 2.47" 2.54" 10XC-877 3 2d" 2.71" 3.08" 2.88" 10XC-878 3 3" 3.15" 3.60" 3.88" 5XC-879 3 3d" 3.20" 4.03" 5.04" 1XC-8710 3 4" 3.15" 4.25" 5.04" 1

U.L. File No. E-17909-d"-f"U.L. File No. E-1275-1b"CSA File No. LR-12798

Figure 1

Figure 2 Figure 3

®®

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E42

Page 43: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E43

Armored Cable/Flexible Metallic Conduit Fittings

Steel City® Cable LokCat. Size AC AC Aluminum MC (I) MC (I) Flex Std.No. Range Steel Interlocked Steel Aluminum RW Ctn.

14/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 c Steel 50XC-730 .450"/.610" 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 & ALd" K.O. 10/2 10/2 10/3 10/2 10/3

14/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 50XC-731 .450"/.610" 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 –d" K.O. 10/2 10/2 10/3 10/2 10/3

10/3 10/4 10/5 10/4 10/5 c Steel 25XC-732 .610"/.875" 8/3 8/4 – 8/3 8/4 – & ALf" K.O. 6/2 6/2

14/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 25XC-7300 .450"/.610" 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 –d" K.O. 10/2 10/2 10/3 10/2 10/3

U.L. File No. E-17909CSA File No. LR-12798

• Simple, one-piece installation with nolocknuts.

• Screw designed for exceptional pullout resistance.

• Captive screw ensures that the screw isintact for installation and resists backingout after installation.

• Corrosion-resistant, zinc-chromaticplating.

• Positive grounding.• Vibration resistant screw design.• UL listed and CSA certified.

1.Simply snap into place.No locknuts required!

2.Insert cord and twist set screw. Connectortightens as screw is set.

Simple, fast steps to installingthe Steel City® Cable Lok.

®®

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E43

Page 44: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E44 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Armored Cable/Flexible Metallic Conduit Fittings

Figure 1

90° Clamp Type Connectors – Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Fig. Size A (min.) A (max.) B Ctn.

XC-290 1 c" (d" KO) 0.40" 0.63" 1.80" 500XC-291 1 d" 0.65" 1.00" 2.08" 250XC-292 1 f" 0.83" 1.25" 2.27" 100XC-293 2 1" 1.27" 1.50" 2.60" 50XC-294 2 1b" 1.49" 1.85" 3.10" 30XC-295 3 1d" 1.51" 2.47" 6.05" 5XC-296 3 2" 1.51" 2.47" 6.05" 5XC-297 4 2d" 2.45" 3.50" 7.75" 2XC-298 5 3" 3.07" 4.02" 8.88" 1XC-299 4 3d" 3.63" 4.34" 12.75" 1XC-2910 4 4" 3.68" 5.17" 12.75" 1

U.L. File No. E-17909CSA File No. LR-18130M57

Insulated Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Fig. Size A (min.) A (max.) B Ctn.

XC-890 1 c" 0.40" 0.63" 1.81" 500XC-891 1 d" 0.65" 0.97" 2.18" 250XC-892 1 f" 0.77" 1.12" 2.38" 100XC-893 2 1" 1.06" 1.40" 2.87" 50XC-894 2 1b" 1.34" 1.65" 3.93" 30XC-895 3 1d" 1.51" 2.47" 6.05" 5XC-896 3 2" 1.51" 2.47" 6.05" 5XC-897 4 2d" 2.45" 3.50" 7.75" 2XC-898 5 3" 3.07" 4.02" 8.88" 1XC-899 4 3d" 3.63" 4.34" 12.75" 1XC-8910 4 4" 3.68" 5.17" 12.75" 1

U.L. File No. E-17909CSA File No. LR-12798

®®

Figure 2

Figure 3

Figure 4

Figure 5

“Threads”

“Threads”

“Threads”

“Threads”

“Threads”

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E44

Page 45: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E45

Armored Cable/Flexible Metallic Conduit Fittings

Clamp Type Connector – Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Size A (min.) A (max.) B Ctn.

XC-280 c" (d" KO) 0.18" 0.64" 1.16" 1000

U.L. File No. E-17909CSA File No. LR-18130M57

Duplex Clamp Type Connector – Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Size A (min.) A (max.) B Ctn.

XC-210 c" (d" KO) 0.13" 0.65" 1.56" 250

CSA File No. LR-18130M57

For use with metal clad cable.

A max.A min.

Snap-In Connector for Flexible Metal Conduit – 105°C RatedCat. K.O. Unit Std.No. Conduit Size Size Qty. Ctn.

100-TB c" d" 50 500100BP c" d" 250 1000

BX Flex Bushings – Anti-ShortCat. Fits Standard Unit Std.No. Cable Range Size Qty. Ctn.

IT-100-SC 14/2-14/3-12/2 0 100 100IT-101 14/4-12/3-6/1-4/1 1 100 35IT-102 12/4-10/2-10/3-2/1 2 50 50IT-103 10/4-8/2-8/3-1/1 3 50 50IT-104 8/4-6/2-6/3-4/2-4/3-6/4 4 50 50

For die cast armored cable/flexible metallic conduit fittings and combination fittings refer to the Steel City® Die CastConduit Fittings section.Ordered by Bags

Cable RangeCat. Continuous Corrugated and Corrugated Aluminum Smooth Extruded Std.No. min. dia. max. dia. min. dia. max. dia. Ctn.

XC-280 – .510" .345" .525" 1000XC-210 – – .410" .500" 250

1-1h"

®®

®

• No locknut required.• No special tools required.• High impact thermoplastic with steel insert.

• Packed in polybags.• Available bulk packed-10,000 per carton.• Plastic.

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E45

Page 46: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

BX Flex Connectors, Saddle Type – Die Cast ZincCat. Dimensions (in.) Std.No. Size A (min.) A (max.) B Ctn.

XC-2200-C c" 0.12" 0.63" 0.98" 500

E46 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Armored Cable/Flexible Metallic Conduit Fittings

XC-220

Straight Set Screw Connectors – Die Cast Zinc – NoninsulatedCat. Dimensions (in.) Std.No. Size A (min.) A (max.) B Ctn.

XC-220 c" (d" KO) 0.38" 0.63" 0.84" 1000

XC-221 d" 0.74" 0.94" 1.46" 250

XC-821 d" 0.74" 0.94" 1.46" 250

XC-220 and XC-221: U.L. File No. E-17909 c"U.L. File No. E-1275 d"

XC-821: U.L. File No. E-1275 d"A max.

A min.

A max.A min.

B A max.A min.

B

XC-221XC-821

Screw-In Connectors – Die Cast Zinc – NoninsulatedCat. Dimensions (in.) Std.No. Size A B Ctn.

XC-240 c" (d" KO) 1.31" 0.92" 500XC-241 d" 1.38" 0.92" 500XC-242 f" 1.62" 1.12" 125XC-243 1" 1.94" 1.37" 125XC-244 1b" 2.12" 1.75" 50XC-245 1d" 2.31" 2.13" 50XC-246 2" 2.58" 2.67" 50

U.L. File No. E-1275CSA File No. LR-18130M57 c"-d"

Screw-In Connectors – Die Cast Zinc – InsulatedCat. Dimensions (in.) Std.No. Size A B Ctn.

XC-840 c" (d" KO) 1.31" 0.92" 500XC-841 d" 1.38" 0.92" 500XC-842 f" 1.62" 1.12" 125XC-843 1" 1.94" 1.37" 125XC-844 1b" 2.12" 1.75" 50XC-845 1d" 2.31" 2.13" 50XC-846 2" 2.58" 2.67" 50

U.L. File No. E-1275CSA File No. LR-18130M57 c"-d"

A

B

Screw-In Couplings – Die Cast ZincCat. Dimensions (in.) Std.No. Size A B Ctn.

XK-241 d" 1.81" 0.92" 250XK-242 f" 2.09" 1.12" 250XK-243 1" 2.41" 1.37" 125XK-244 1b" 2.75" 1.81" 50XK-245 1d" 3.05" 2.12" 50XK-246 2" 3.28" 2.67" 50

U.L. File No. E-1275

A

B

®

®

®

®®

®

A

B

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E46

Page 47: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E47

Cable Straps, Cable Caps

Service Cable Straps – One HoleCat. Fits Shelf Ship Std.No. Cable Ctn. Case Ctn.

SE100 3#8, 3#6, 3#4 100 1000 1000SE101 3#3, 3#2 100 1000 1000SE102 3#1, 3#0, 3#1/0, 3#2/0 25 250 250SE103 3#3/0, 3#4/0 25 250 250

Service Cable Caps – OvalCat. Fits Dimensions (Inches) Std.No. Cable A B C Ctn.

50130 To 2/0-3 5.00 3.31 4.75 1050130A To 4/0-3 6.75 4.62 6.00 5With Split Insulator

SC1000 3#3-2 2.37 2.12 2.25 25SC2001 3#3/0-4/0 4.93 3.12 3.75 10

Extra Large Body for Additional Wiring Space.

Service Cable Straps – Two HoleCat. Fits Shelf Ship Std.No. Cable Ctn. Case Ctn.

SE900 3#8, 3#6, 3#4 100 1000 1000SE901 3#3, 3#2 100 1000 1000SE902 3#1, 3#0, 3#1/0, 3#2/0 25 250 250SE903 3#3/0, 3#4/0 25 250 250

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E47

Page 48: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E48 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Service Entrance Fittings

Aluminum Service Caps – Clamp Type for Rigid/Intermediate or Thinwall

Cat. Conduit Std.No. Size No. Hole Size Ctn.

SH-101 d" 4 ∫" 50SH-102 f" 5 2(c") 3(u") 50SH-103 1" 5 2(k") 3(d") 10SH-104 1b" 5 2(N") 3(e") 10SH-105 1d" 6 2(x") 1(k") 3(f") 5SH-106 2" 6 2(f") 3(1") 1(w") 5SH-107 2d" 7 3(g") 1(1") 3(1j") 1SH-108 3" 7 4(1a") 3(1f") 1SH-109 3d" 4 4(1f") 2(a") 1SH-110 4" 4 4(1f") 2(1a") 1

CSA File No. LR-12798U.L. File No. E-22753

A

BService Entrance Fittings

Cat. Trade Std.No. Size A B Ctn.

ASLB-1 d" 3h 1l 50ASLB-2 f" 3l 1f 50ASLB-3 1" 4b 2i 25ASLB-4 1b" 5d 3 10ASLB-5 1d" 6b 3b 10ASLB-6 2" 6f 4 5DASLB-1 d" 3h 1l 24DASLB-2 f" 3l 1f 20DASLB-3 1" 4b 2i 8

Service Entrance Fittings – Standard d" - 2"Cat. Trade Std.No. Size A B Ctn.

ASLB-1 d" 3h 1l 50ASLB-2 f" 3l 1f 50ASLB-3 1" 4b 2i 25ASLB-4 1b" 5d 3 10ASLB-5 1d" 6b 3b 10ASLB-6 2" 6f 4 5

Service Entrance Fittings – Standard d" - 4"Cat. Trade Std.No. Size A B Ctn.

SALB-7 2d" 3h 1l 50SALB-8 3" 3l 1f 50SALB-9 3d" 4b 2i 25SALB-10 4" 5d 3 10

TYPE LB

®

®

®

®

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E48

Page 49: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E49

Grounding Clamps/Connectors

Ground Clamps – Die Cast Zinc Alloy for Armored Ground WireCat. Conduit Std.No. Conduit Size Ctn.

GA-203 d"; f"; 1" 250

U.L. File No. E-10661

Ground Clamps – Die Cast Zinc, Brass ColoredCat. Conduit Std.No. Conduit Size Ctn.

GC-203-B d"; 1" 200

Two-screw ground connection forarmored ground wire.

Water-Tight ConnectorsCat. Trade Rubber Grommet Opening Std.No. Size Fits Cable A B Ctn.

WT-203A 1" 3#8 .500 .750 100WT-203B 1" 3#6 .563 .844 100WT-203C 1" 3#4 .625 .938 100WT-204A 1b" 3#3 .625 1.000 50WT-204B 1b" 3#2 .580 .960 50WT-204C 1b" 3#1 .660 1.090 50WT-204D 1b" 3#1/0 .750 1.125 50WT-205A 1d" 3#1/0 & 3#2/0 .735 1.240 20WT-205B 1d" 3#2/0 & 3#3/0 .875 1.375 20WT-205C 1d" 3#2/0 & 3#3/0 .938 1.438 20WT-206A 2" 3#1/0 & 3#2/0 .735 1.240 20WT-206B 2" 3#2/0 & 3#3/0 .875 1.375 20WT-206C 2" 3#2/0 & 3#3/0 .938 1.438 20WT-206D 2" 3#4/0 .890 1.550 20WT-206E 2" 3#4/0 1.063 1.688 20

For Underground Feeder Cable

UF-201 d" 2#14 .210 .440 250UF-202 f" 3#14 .220 .660 250

• For Type SE, Style U, Flat; 2 InsulatingConductors, 1 Bare.

A

B

®

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E49

Page 50: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E50 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Gutter Connectors/Cable Protector and Cable Clip

Gutter Connectors

1-2o"

A

3 PiecesSteel/Zinc Plated

Locknut

Spacer

Fitting

1"

1"

1a"

c"

Cable ProtectorCat. Std.No. Description Ctn.

CP-1 Steel 100

1c"

1l"

Cable ClipCat. Std.No. Description Ctn.

NS-100 Steel 1000

Gutter Connectors StraightCat. Conduit Std.No. Size A Dia. Ctn.

UC-101 d" 1a" 250UC-102 f" 1k" 250UC-103 1" 1f" 150UC-104 1b" 2a" 90UC-105 1d" 2d" 50UC-106 2" 2n" 30

U.L. File No. E-1275

Replaces conventional method ofnipple, locknuts and bushings tointerconnect panel boxes and othertype enclosures to troughs or gutters.Gutter connectors provide automaticuniform 1" spacing with no threadsshowing.Conventional installation requires that anipple be used with double locknuts at

both ends or with a bushing andlocknut at each end. Also, when usingtwo or more nipples, time is consumedadjusting the nipples for straightalignment of the enclosure. Gutterconnectors eliminate these timeconsuming methods. The three piececonnector requires the tightening ofonly one locknut.

®

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E50

Page 51: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E51

Beam Clamps for Mounting Pipe or Conduit

Conduit/Pipe to Beam ClampsDimensions in Inches

Cat. O.D. of Conduit Nom. Conduit or Std.No. & Size or Pipe Pipe Size Ctn.

RCS Clamp – Steel

RCS-1/2 .840 d 50RCS-3/4 1.050 f 50RCS-1 1.315 1 50RCS-1-1/4 1.660 1b 50RCS-1-1/2 1.900 1d 50RCS-2 2.375 2 50

RC Clamp – Malleable Iron

RC-3/8 .675 c 50RC-1/2 .840 d 50RC-3/4 1.050 f 50RC-1 1.315 1 50RC-1-1/4 1.660 1b 50RC-1-1/2 1.900 1d 50RC-2-SC 2.375 2 50RC-2-1/2 2.875 2d 25RC-3 3.500 3 25RC-3-1/2 4.000 3d 25RC-4-SC 4.500 4 20

EC Clamp – Malleable Iron

EC-1/2 .840 d 50EC-3/4 1.050 f 50EC-1 1.315 1 25EC-1-1/4 1.660 1b 25EC-1-1/2 1.900 1d 25EC-2 2.375 2 25EC-2-1/2 2.875 2d 10

PC Clamp – Malleable Iron

PC-3/8 .675 c 50PC-1/2 .840 d 50PC-3/4 1.050 f 50PC-1 1.315 1 50PC-1-1/4 1.660 1b 25PC-1-1/2 1.900 1d 25PC-2 2.375 2 25PC-2-1/2 2.875 2d 25PC-3 3.500 3 10PC-3-1/2 4.000 3d 10PC-4 4.500 4 10

• For mounting pipe or conduit at right anglesto the beam.

• SS316 Suffix Stainless Steel.• HDG Suffix – Hot Dip Galvanized.

RCS Series

• For mounting pipe or conduit verticallyacross the beam.

• HDG Suffix – Hot Dip Galvanized.

• For mounting pipe or conduit parallel to thebeam.

• HDG Suffix – Hot Dip Galvanized.

EC Series

PC Series

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E51

Page 52: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

E52 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Conduit and Pipe Hangers

6H Series Conduit and Pipe Hangers – Without BoltSize (in.)

Dimensions (in.)Cat. Rigid Conduit Load Std.No. or Pipe EMT A B C D (dia.) Rating Ctn.

6H0 c - d d f .045 1y s 500 1006H0-T c - d d f .045 1B s 500 1006H1 f f g .045 1O s 500 1006H1-T f f g .045 2s s 500 1006H2 1 1 g .045 2c s 500 1006H2-1/2 – 1b g .045 2z s 500 1006H3-SC 1b 1d g .045 2g s 500 100

6H4 1d – 1 .071 3c X 500 1006H5 2 2 1b .071 3C X 500 506H6 2d – 1b .071 4s X 500 506H7 3 – 1b .071 5i X 500 256H8 3d – 1b .071 5k X 500 256H9 4 4 1b .071 5g X 500 10

* Add SS suffix to part number for stainless steel.Load rating is 500 lbs. with a safety factor of 3. Available with or without closure bolt. Standard finishes: electrogalvanizedand Type 302 Stainless Steel.

For hanging conduit (rigid or EMT) and pipe.The 6H series hangers are fast, easy andeconomical to use. May be fastened directlyto a #500 beam clamp through a hole in thebase of the hanger by means of a 1⁄4-20 stovebolt or suspended on 1⁄4" hanger rod.

Without Bolt

6H Series Conduit and Pipe Hangers – With BoltSize (in.)

Dimensions (in.)Cat. Rigid Conduit Load Std.No. or Pipe EMT A B C D (dia.) Rating Ctn.

6H0-B c - d d f .045 1y s 500 1006H0-TB c - d d f .045 1B s 500 1006H1-B f f g .045 1O s 500 1006H1-TB f f g .045 2s s 500 1006H2-B 1 1 g .045 2c s 500 1006H2-1/2-B – 1b g .045 2z s 500 1006H3-SC-B 1b 1d g .045 2g s 500 100

6H4-B 1d – 1 .071 3c X 500 1006H5-B 2 2 1b .071 3C X 500 506H6-B 2d – 1b .071 4s X 500 506H7-B 3 – 1b .071 5i X 500 256H8-B 3d – 1b .071 5k X 500 256H9-B 4 4 1b .071 5g X 500 10

* Add SS suffix to part number for stainless steel. (not UL listed.)Load rating is 500 lbs. with a safety factor of 3. Available with or without closure bolt. Standard finishes: electrogalvanizedand Type 302 Stainless Steel.

6HWithout bolt.

6H-BWith bolt and hex nut.

6H-TThreaded without bolt.

6H-TBThreaded with bolt.

®

®

Beam ClampCat. Std.No. Size Tapped Ctn.

BC1-TB 1 b-20 250

BC2-TB 2n c-16 –

Material: SteelFinish: Zinc Plated

All Steel City 6H Hanger Bolts include acombination Slot-Phillips Head.

E

Stee

l Cit

412034.E01 5/7 5/7/03 4:52 PM Page E52

Page 53: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E53

Beam Clamps/Threaded Rod/Rod Coupling

Beam Clamps – Malleable Iron, Electroplated FinishBase Size Jaw Tapping

Cat. Inches Opening of Base Load Std.No. A B Inches and Back Holes Rating‡ Ctn.

510 B 1a e b-20 400 100511-SC B 1a e 10-24 400 100500-SC 1 1b n b-20 450 50509 1 1b n 10-24 375 100501 1d 1e g j-18 800 50502 2 2 1 c-16 1300 50503-SC 2e 2d 1 d-13 1300 20507 2d 2c 1c d-13 1700 20508 2d 2c 2a d-13 1700 10

‡Safety Factor of 3.Loan Ratings based on bottom hole of Beam Clamp.CSA File No. LR-52208

R-Series Continuous Thread Rod – GalvanizedData for Pressure Piping

Cat. Rod Ultimate‡ Root Area Nominal Max. Safe Std.No. Size Load in Lbs. Thread Pipe Size Load at 450° Ctn.

R628-6 ft. b-20 900 .027 300R638-6 ft. c-16 1900 .068 f" to 2" 610 150R648-6 ft. d-13 3500 .126 2d" to 3d" 1130 60R1028-10 ft. b-20 900 .027 500R1038-10 ft. c-16 1900 .068 f" to 2" 610 250R1048-10 ft. d-13 3500 .126 2d" to 3d" 1130 100

‡Load Ratings based on safely factor of three.

H-195 Steel Rod CouplingCat. Dimensions in Inches Std.No. Rod Size A B Ctn.

H-195-1/4 b f c 1000H-195-3/8 c 1 d 500H-195-1/2 d 1 e 500H-195-5/8 e 1d f 50

E

Steel City®

412034.E01 5/7 5/7/03 4:52 PM Page E53

Page 54: Commercial and Die Cast Fittings - Cesco.com · Conduit Fittings Advantages of Steel City Commercial Conduit Fittings Compression Fittings Dependable Pipe Stop • Strong thick protrusion

You’ve told us what your customers say ... how they work ... and what they need for a better,faster, easier job. And we’ve used your feedback tomake Steel City® the most versatile and trusted

brand in the industry! And now the line is bigger and

stronger than ever. Steel City® boxesnow include exclusive new features tohelp simplify and speed up installations.We’ve upgraded the extensive line of

Steel City Fittings for added convenience and reliability. And we’ve added a new line of over 600Steel City Spring Steel Fasteners that meet all thecurrent UL test requirements.

Thomas & Betts and you – together we’re building on a century of trust. For technical information about any product in the Steel City line, call 1-888-862-3289.

SH2346 Box-to-Stud BracketUnique side brace allows one part number toattach boxes to 2 1/2,” 3 1/2,” 4,” or 6” metal orwood studs. (Competition needs three.)

CK Series Conduit to Drop Wire FastenersLarger finger tab, better leverage, makes it easierto secure MC/AC cables and conduit to drop wire,plain and threaded rods, and flanges.

Steel City ® • Red•Dot ® • Superstrut ® • Union ® • Bowers ®

Steel City ®...Building on a century

of trust!

412034.E01 5/7 5/7/03 4:52 PM Page E54