Commercial and Die Cast Fittings
Conduit Fittings. . . . . . . . . . . . . . . . . . . . . . . . . . . . E2
Thinwall Conduit Fittings (EMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E3-E14
Rigid/Intermediate Grade Conduit Fittings . . . . . . . . . . . . . . . . . . . . . E15-E27
Rigid/Aluminum Conduit Bodies,Gaskets and Covers . . . . . . . . . . . . . . . . . E28-E29
Aluminum Conduit Bodies,Gaskets and Covers . . . . . . . . . . . . . . . . . . . . . E30
Flexible Cord and Power CableConnectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . E31
Liquidtight Flexible Nonmetallic Conduit Connectors and Tubing . . . . . . . . E32-E33
Liquidtight Fittings. . . . . . . . . . . . . . . . . . . . . . . . . E34
Liquidtight Flexible Metal Conduit Connectors . . . . . . . . . . . . . . . . . . E35-E37
Nonmetallic Sheathed Cable andFlexible Cord Connectors . . . . . . . . . . . . . . . . . E38
Nonmetallic SheathedCable Fittings . . . . . . . . . . . . . . . . . . . . . . . E39-E40
Armored Cable/Flexible MetallicConduit Fittings . . . . . . . . . . . . . . . . . . . . . E41-E46
Cable Straps, Cable Caps . . . . . . . . . . . . . . . . . . E47
Service Entrance Fittings . . . . . . . . . . . . . . . . . . . E48
Grounding Clamps/Connectors . . . . . . . . . . . . . . E49
Gutter Connectors/Cable Protectorand Cable Clip . . . . . . . . . . . . . . . . . . . . . . . . . . E50
Beam Clamps for Mounting Pipeor Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E51
Conduit and Pipe Hangers . . . . . . . . . . . . . . . . . . E52
Beam Clamps/Threaded Rod/Rod Coupling. . . . . . . . . . . . . . . . . . . . . . . . . . . E53
E
412034.E01 5/7 5/7/03 4:51 PM Page E1
Steel City® Conduit Fittings provide long-lasting service in commercial,industrial and residential construction. Our fittings are manufacturedwithin strict tolerances to maintain consistent performance. Installerscan be assured that every fitting with the Steel City name will work
every time. So when you select Steel City® Conduit Fittings, thatmeans fewer headaches and call-backs.
Steel City® products symbolize the highest quality standards inmanufacturing and innovative design, with one of the mostcomplete offerings available. Contact a T&B distributor nearestyou to select the right Steel City® product for your requirements.
E2 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Conduit Fittings
Advantages of Steel City Commercial Conduit Fittings
Compression FittingsDependable Pipe Stop• Strong thick protrusion that does not exceed thickness of EMT. Keeps forcefully inserted
conduit from breaking through the opposite side of the coupling while not interfering with thepulling of conductors.
Heavy Duty Thick Steel Body/Glands withContinuous Threading• True hexagonal shape. The non-circular design
has actual flats for gripping power using hand ortool force.
Extra Thick Electroplated Zinc Finish • Assures corrosion resistance while the clear
chromate coating gives the fittings their qualityshine and luster.
Couplings and ConnectorsSuperior Quality and Design• Strict tolerances throughout fitting assures a straight conduit run with no
sagging over extreme lengths. • Chamfered entry provides lead-in for conduit insertion.
Dependable Pipe Stop• 360° grove traveling the circumference assures that conduit forcefully
inserted won't break through to the opposite side of the fitting. Also, itdoes not exceed thickness of EMT and prevents interference withpulling conductors.
Extra Large Head Tri-Drive Set-Screw • Accommodates Phillips, Slotted and Square
drives.
Enhanced LocknutConstruction• Heavy-duty turned sharp
teeth, double-threaded.
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E2
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E3
Thinwall Conduit Fittings (EMT)
1st Digit – Material1 = Steel2 = Die Cast3 = Combination Steel and Die Cast4 = Malleable5 = Plastic6 = Aluminum7 = Steel Insulated8 = Die Cast Insulated9 = Malleable Insulated
2nd Digit – Method1 = Compression2 = Set Screw3 = Other
3rd/4th Digit Size1 = d"2 = f"3 = 1"4 = 1b"5 = 1d"6 = 2"7 = 2d"8 = 3"9 = 3d"10 = 4"11 = 5"12 = 6"A few examples of the three digitidentification system for thinwallfittings are:TK-111 d" steel, compression
type couplingTC-714 1b" steel insulated
compression typeconnector
TC-822 f" die cast, insulated,set-screw typeconnector
Easy to identify alphabetical prefixes:BG – Bushings, GroundingBI – Bushings, InsulatedBL – BlanksBU – BushingsCB – Clamp BackEK – 3 Piece CouplingGA – Ground Clamp (armored ground
wire)GC – Ground ClampHA – Heavywall AdapterHC – Heavywall ConnectorHK – Heavywall CouplingHO – Heavywall OffsetHS – Heavywall StrapLG – Locknut, GroundingLN – LocknutLT – LiquidtightNC – Nonmetallic Sheathed Cable
ConnectorNS – Nonmetallic Sheathed Cable
StrapSH – Service Entrance FittingSL – Service EllsSR – Sealing RingsLS – Locknut, SealingTC – Thinwall ConnectorsTK – Thinwall CouplingsTO – Thinwall OffsetTS – Thinwall StrapTX – Thinwall to Flexible Metallic
Conduit FittingUC – Utility ConnectorWA – WasherXC – Armored Cable or Flexible
Metallic Conduit ConnectorXK – Armored Cable or Flexible
Metallic Conduit Coupling
Here’s How The Steel City Part Number System Works
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E3
E4 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Thinwall Conduit Fittings (EMT)
Set Screw Connectors, Steel – Non-Insulated"A" Cat# Conduit Size Inner Pack Outer Pack
TC121A d" 50 500TC122A f" 50 250TC123A 1" 25 100TC124A 1b" – 25TC125A 1d" – 25TC126A 2" – 25TC127A 2d" – 10TC128A 3" – 5TC129A 3d" – 5TC1210A 4" – 5
Set Screw Connectors, Steel – Insulated"A" Cat# Conduit Size Inner Pack Outer Pack
TC721A d" 50 500TC722A f" 50 250TC723A 1" 25 100TC724A 1b" – 25TC725A 1d" – 25TC726A 2" – 25TC727A 2d" – 10TC728A 3" – 5TC729A 3d" – 5TC7210A 4" – 5
U.L. File No. E-16592
• Concrete Tight• Zinc Plated
NewDesign
®
Set Screw Couplings – Steel"A" Cat# Conduit Size Inner Pack Outer Pack
TK121A d" 50 500TK122A f" 50 250TK123A 1" 25 100TK124A 1b" – 25TK125A 1d" – 25TK126A 2" – 25TK127A 2d" – 10TK128A 3" – 5TK129A 3d" – 5TK1210A 4" – 5
U.L. File No. E-16592• Concrete Tight, when taped• Zinc Plated
NewDesign
®
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E4
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E5
Thinwall Conduit Fittings (EMT)
Compression Connectors, Steel – Non-Insulated"A" Cat# Conduit Size Inner Pack Outer Pack
TC111A d" 50 500TC112A f" 50 250TC113A 1" 25 100TC114A 1b" – 25TC115A 1d" – 25TC116A 2" – 25TC117A 2d" – 10TC118A 3" – 5TC119A 3d" – 5TC1110A 4" – 5
Compression Connectors, Steel – Insulated"A" Cat# Conduit Size Inner Pack Outer Pack
TC711A d" 50 500TC712A f" 50 250TC713A 1" 25 100TC714A 1b" – 25TC715A 1d" – 25TC716A 2" – 25TC717A 2d" – 10TC718A 3" – 5TC719A 3d" – 5TC7110A 4" – 5
U.L. File No. E-16592
• 1⁄2" – 4" Concrete Tight• Zinc Plated
NewDesign
®
Compression Couplings – Steel"A" Cat# Conduit Size Inner Pack Outer Pack
TK111A d" 50 250TK112A f" 50 250TK113A 1" 25 100TK114A 1b" – 25TK115A 1d" – 25TK116A 2" – 25TK117A 2d" – 10TK118A 3" – 5TK119A 3d" – 5TK1110A 4" – 5
U.L. File No. E-16592• 1⁄2" – 4" Concrete Tight• Zinc Plated
NewDesign
®
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E5
E6 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Thinwall Conduit Fittings (EMT)
EMT LOK Conduit ConnectorCat. Std.No. Description Ctn.
TC-101-SC d" Uninsulated 500TC-102-SC f" Uninsulated 250TC-701-SC d" Insulated 500TC-702-SC f" Insulated 250
U.L. Listing No. E16592, CSA Listing No. LR-12798Installation using either slotted or Phillips screwdriver head, 35-in-lb of torque onto the EMT.NOTE: Excessive torque could damage EMT or housing.• Simple, one-piece installation with no
locknuts.• Available in insulated or noninsulated throat.• Screw designed for exceptional pullout
resistance.• Captive screw ensures that the screw is intact
for installation and resists backing out afterinstallation.
• Corrosion-resistant, zinc-chromatic plating.• Concrete tight.• Positive grounding.• Vibration resistant screw design.• UL listed and CSA certified.
®®
E
Stee
l Cit
y®
Steel City ® Steel Boxes, Covers, & Accessories• Notched Ears on Switch Boxes provide clearance for the screws that are used to attach
wall plates to GFCI or rocker-type light switches.• Universal Metal Stud Bracket mounts without the use of screws, to the open or closed
side of the stud and works on any depth of non-loadbearing metal stud.• Eccentric Knockouts on Square Boxes provide better contact with conduit fitting
and locknut to the box, improves grounding path, stronger than f" knockout.• Improved f" Knockout Position on Square Boxes requires less labor to
install f" conduit to box.• Raised Ground Screw in Utility Boxes make for quicker surface
mounting by eliminating the need to remove the portion of the screw thatthreads through the back of the box, allows for improved repositioning ofgrounding conductor.
• Preinstalled Screws are Packaged in raised position eliminates extra step ofhaving to back out the screw during cover installation.
Steel City ® Underfloor Duct, Floor Boxes, & Poke-Throughs• Steel City conventional underfloor duct offers multi-compartmental duct and junction boxes with built-
in tile trim.• Header duct and access hatch designs of cellular underfloor duct system provide convenient
wire and cable access, eliminating junction boxes.• Accommodate power, voice, or data with Steel City flush floor boxes, available in cast-iron,
steel, and nonmetallic constructions.• Access floor modules blend with any decor and accommodate virtually any raised floor
surface.• Steel City poke-through devices allow the interchange of flush, low-profile, and standard
service heads without removing the lower core unit.
Additional Commercial Construction Products from Thomas & Betts
412034.E01 5/7 5/7/03 4:52 PM Page E6
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E7
Thinwall Conduit Fittings (EMT)
Compression Connectors – Die Cast Zinc, InsulatedCat. Conduit Std.No. Size A B Ctn.
TC-811-SC d" 1R" ©" 500TC-812-SC f" 1v" n" 250TC-813-SC 1" 1{" 1v" 200TC-814-SC 1b" 1C" 1B" 100TC-815-SC 1d" 1O" 2h" 40TC-816-SC 2" 2b" 2w" 20TC-817-SC 2d" 2A" 3b" 12TC-818-SC 3" 2O" 3n" 12TC-819-SC 3d" 2B" 4k" 10TC-8110-SC 4" 2C" 4n" 6
U.L. File No. E-16592 – d"-4"CSA File No. LR-12798 – d"-2
• 1⁄2" – 4" Concrete Tight
A
B
Offset Compression Connectors – Die Cast ZincCat. Conduit Std.No. Size A B Ctn.
TO-211SC c" offset d" 2$" 1" 200TO-212 f" offset f" 2.98" 1.16" 100
U.L. File No. E-16592
A
B
Compression Couplings – Die Cast ZincCat. Conduit Std.No. Size A B Ctn.
TK-211-SC d" 1d" 1p" 500TK-212-SC f" 1e" 1j" 250TK-213-SC 1" 1g" 1}" 200TK-214-SC 1b" 1m" 2p" 100TK-215-SC 1d" 2s" 2Q" 40TK-216-SC 2" 2X" 2C" 20TK-217-SC 2d" 3$" 3™" 12TK-218-SC 3" 3r" 4d" 12TK-219-SC 3d" 3!" 5h" 10TK-2110-SC 4" 3i" 5G" 6
U.L. File No. E-16592 – d"-4"CSA File No. LR-12798 – d"-1b", 2d"-4"
®®
®®
®
• 1⁄2" – 4" Concrete Tight
A
B
Compression Connectors – Die Cast Zinc, NoninsulatedCat. Conduit Std.No. Size A B Ctn.
TC-211-SC d" 1b" 1 500TC-212-SC f" 1X" 1q" 250TC-213-SC 1" 1S" 1v" 200TC-214-SC 1b" 1m" 1B" 100TC-215-SC 1d" 1g" 2h" 40TC-216-SC 2" 2q" 2w" 20TC-217-SC 2d" 2}" 3b" 12TC-218-SC 3" 2g" 3n" 12TC-219-SC 3d" 2I" 4k" 10TC-2110-SC 4" 2m" 4n" 6
U.L. File No. E-16592 – d"-4"CSA File No. LR-12798 – d"-2
®®
• 1⁄2" – 4" Concrete Tight
A
B
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E7
Set Screw Connectors – Die Cast Zinc, NoninsulatedCat. Conduit A Std.No. Size TC-221 Series TC-821 Series B Ctn.
TC-221-SC d" 1q" 1å" n" 500TC-222-SC f" 1u" 1E" 1q" 250TC-223-SC 1" 1l" 1y" 1N" 200TC-224-SC 1b" 1n" 2o" 1m" 100TC-225-SC 1d" 2s" 2c" 2Y" 40TC-226-SC 2" 2E" 2T" 2w" 20TC-227-SC 2d" 3i" 3s" 3∫" 12TC-228-SC 3" 3ç" 3M" 4h" 12TC-229-SC 3d" 3M" 3x" 4w" 10TC-2210-SC 4" 3I" 3K" 5h" 6
NoninsulatedU.L. File No. E-16592 – d"-2"U.L. File No. E-1275 – 2d"-4"CSA File No. LR-12798 – d"-1", 2d"-4"
Set Screw Connectors – Die Cast Zinc, InsulatedCat. Conduit A Std.No. Size TC-221 Series TC-821 Series B Ctn.
TC-821-SC d" 1q" 1å" n" 500TC-822-SC f" 1u" 1E" 1q" 250TC-823-SC 1" 1l" 1y" 1N" 200TC-824-SC 1b" 1n" 2o" 1m" 100TC-825-SC 1d" 2s" 2c" 2Y" 40TC-826-SC 2" 2E" 2T" 2w" 20TC-827-SC 2d" 3i" 3s" 3∫" 12TC-828-SC 3" 3ç" 3M" 4h" 12TC-829-SC 3d" 3M" 3x" 4w" 10TC-8210-SC 4" 3I" 3K" 5h" 6
InsulatedU.L. File No. E-16592 – d"-2"U.L. File No. E-1275 – 2d"-4"CSA File No. LR 12798 – d"-2"
E8 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Thinwall Conduit Fittings (EMT)
• Concrete Tight, when taped
A
B
• Concrete Tight, when taped
Set Screw Couplings – Die Cast ZincCat. Conduit Std.No. Size A B Ctn.
TK-221 d" 1E" ∂" 500TK-222 f" 1C" 1q" 250TK-223 1" 2" 1k" 200TK-224 1b" 2E" 1B" 100TK-225 1d" 2B" 2h" 40TK-226 2" 3u" 2d" 20TK-227 2d" 4r" 3∫" 12TK-228 3" 4W" 4Y" 12TK-229 3d" 4B" 4w" 10TK-2210 4" 5v" 4l" 6
U.L. File No. E-16592 – d"-2"U.L. File No. E-1275 – 2d"-4"CSA File No. LR-12798 – d"-1b", 2d"-4"
®®
®®
• Concrete Tight, when taped
A
B
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E8
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E9
Thinwall Conduit Fittings (EMT)
Capped Corner Couplings – Die-Cast ZincCat. Conduit Std.No. Size A B Ctn.
TL-291 d" 1.81" 1.00" 100TL-292 f" 2.00" 1.25" 50
U.L. File No. E-16592CSA File No. LR-12798
• Concrete Tight, when taped
• Concrete Tight, when taped
EMT to Box Set Screw Type – Die-Cast ZincCat. Conduit Std.No. Size A B Ctn.
TL-211 d" 1.31" .93" 100TL-212 f" 1.47" 1.22" 50
U.L. File No. E-1275
EMT to EMT Set Screw Type – Die-Cast ZincCat. Conduit Std.No. Size A B Ctn.
TL-201 d" 1.31" 1.10" 100TL-202-SC f" 1.60" 1.24" 50TL-203 1" 1.94" 1.59" 25TL-204 1b" 2.26" 1.97" 25
U.L. File No. E-1275
Set Screw Connectors – Die-Cast Zinc, OffsetCat. Conduit Std.No. Offset Size A B C Ctn.
TO-221 c" d" 2.00" .90" .37 100TO-222 f" f" 2.98" 1.16" .25 100TO-223 f" 1" 3.15" 1.42" .75 100
U.L. File No. E-16592CSA File No. LR-18130M57
SET SCREW TYPE
B C
A
COMPRESSION TYPE
B C
A
EMT Connectors 90° Angle – Die Cast ZincCat. Trade Std.No. Size A B C Ctn.
SET SCREW TYPE
TC-921 d" 1.27 1.15 .45 200COMPRESSION TYPE
TC-911-SC d" 1.37 1.15 .45 200TC-912-SC f" 1.86 .95 .52 200
®
®®
®®
®
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E9
Thinwall Conduit Fittings (EMT)
E10 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Combination Set Screw Couplings – Die-Cast Zinc Flexible Metal Conduit to EMT
Cat. Conduit Std.No. Size A B Ctn.
TX-220 c" flex to d" EMT 1e" d" 500TX-221 d" flex to d" EMT 1m" 1q" 250TX-222 f" flex to f" EMT 1O" 1X" 150TX-223 1" flex to 1" EMT 2ƒ" 1e" 150
U.L. File No. E-1275• Concrete Tight, when taped
A
B
Combination Set Screw Couplings – Thinwall to Heavywall – Die-Cast Zinc
Cat. Conduit Std.No. Size A B Ctn.
HT-221 d" EMT to d" Rigid 1.67" 1.07" 500HT-222 f" EMT to f" Rigid 1.98" 1.29" 250HT-223 1" EMT to 1" Rigid 2.15" 1.58" 100
U.L. File No. E-1275• Concrete Tight, when taped
Combination Compression Couplings – Thinwall to Liquidtight Flexible Metal Conduit – Steel
Cat. Conduit Std.No. Size A B C Ctn.
LTT-111 d" EMT to d" Liquidtight 1f" n" 1a" 100LTT-112 f" EMT to f" Liquidtight 1f" 1™" 1c" 50LTT-113 1" EMT to 1" Liquidtight 1n" 1d" 1f" 25• Steel
• Rain Tight• Zinc Plated
A
CCorner
BCorner
Combination Compression Couplings – Heavywall to Liquidtight Flexible Metal Conduit – Steel
Cat. Conduit Std.No. Size A B C Ctn.
LTH-111 d" Rigid to d" Liquidtight 1g" 1a" 1a" 100
• Steel• Rain Tight• Zinc Plated
A
CCorner
BCorner
®
®
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E10
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E11
Thinwall Conduit Fittings (EMT)
Combination Couplings – EMT to Flex Compression to Screw-In Type – Die Cast Zinc
Cat. Trade Std.No. Size A B Ctn.
TX-201 d" 0.84 1.10 500TX-202 f" 0.95 1.30 250
Combination Couplings – EMT to Flex Set Screw Type – Die Cast Zinc
Cat. Trade Std.No. Fig. # Size A-Min A-Max B Ctn.
TX-210 1 d" - c" 0.15 0.61 1.16 250TX-211 2 d" - d" 0.60 1.00 1.71 250TX-212 2 f" - f" 0.78 1.20 1.93 200
Fig. “1”d"–c"
Fig. “2”d"–d" f"–f"
One Hole Snap-Straps – SteelCat. Conduit Std.No. Size A B Ctn.
TS-101 d" 0.57" 1.79" 1000TS-102 f" 0.62" 1.96" 500TS-103 1" 0.75" 2.25" 500TS-104 1b" 0.88" 2.85" 250TS-105 1d" 0.99" 3.16" 100TS-106 2" 1.10" 3.93" 50HS-107 2d" 1.28" 5.00" 25HS-108 3" 1.28" 5.55" 25HS-109 3d" 1.28" 6.37" 10HS-110 4" 1.28" 6.87" 10
A
B
• Steel• Zinc Plated
Pipe Spacers for Thinwall or Heavywall – Die CastCat. Conduit Std.No. Size A B Ctn.
CB-201 d" 2" 1" 1000CB-202 f" 2c" 1h" 500CB-203 1" 2f" 1j" 500CB-204 1a" 2c" 1d" 250CB-205 1d" 3m" 1e" 100CB-206 2" 4d" 2" 50
A
B
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E11
Thinwall Conduit Fittings (EMT)
E12 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Two Hole EMT Straps – SteelCat. Conduit Std.No. Size A B Ctn.
TS-901 d" 0.56" 2.20" 250TS-902 f" 0.62" 2.67" 200TS-903 1" 0.68" 2.97" 100TS-904 1b" 0.75" 3.67" 50TS-905 1d" 0.88" 4.22" 200TS-906 2" 1.00" 4.91" 25
• Steel• Zinc Plated
A
B
Nail Strap – SteelCat. Rigid/MC EMT Flex Std.No. Size Size Size A B Ctn.
N-101-SC – d" c" 1n" 1Z" 1000N-102-SC d" f" d" 2i" 1w" 1000N-103-SC f" 1" – 2c" 1v" 1000
• Stamped Steel• Zinc Plated
B
A
Space Caps – PlasticCat. Conduit Std.No. Size A B Ctn.
BT-501 d" 2v" 1E" 100BT-502 f" 2v" 1I" 100BT-503 1" 2v" 1O" 100BT-504 1b" 2v" 2M" 100BT-505 1d" 2v" 3o" 100
A
B
Space Cap
EMT Connector
EMT Connectors – Two Piece Type – Die Cast ZincCat. Trade Std.No. Size A B Ctn.
TC-201-SC d" 0.68 1.05 1000
UL File No. E16592
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E12
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E13
Aluminum Conduit Bodies, Covers and Gaskets – LB StyleCat. Trade Std.No. Size A B Ctn.
BLB-1 d" 3g 2h 50BLB-2 f" 4e 2k 50BLB-3 1" 5c 2f 25BLB-4 1b" 7b 3l 10BLB-5 1d" 7b 3m 10BLB-6 2" 9d 4d 5BLB-7* 2d" 12b 5b 1BLB-8* 3" 12b 5g 1BLB-9* 3d" 15 6n 1BLB-10* 4" 15 6n 1
* Shipped with cover. Price includes cost of cover and body.
Thinwall Conduit Fittings (EMT)
TYPE BLR
TYPE BLL
Aluminum Conduit Bodies, Covers and Gaskets – LR StyleCat. Trade Std.No. Size A B Ctn.
BLR-1 d" 3g 2 50BLR-2 f" 4e 2j 50BLR-3 1" 5c 2d 25BLR-4 1b" 7b 3c 10BLR-5 1d" 7b 3c 10BLR-6 2" 9d 3n 5BLR-7* 2d" 12b 5d 1BLR-8* 3" 12b 5d 1BLR-9* 3d" 15 6d 1BLR-10* 4" 15 6d 1
* Shipped with cover. Price includes cost of cover and body.
Aluminum Conduit Bodies, Covers and Gaskets – LL StyleCat. Trade Std.No. Size A B Ctn.
BLL-1 d" 3g 2 50BLL-2 f" 4e 2j 50BLL-3 1" 5c 2d 25BLL-4 1b" 7b 3c 10BLL-5 1d" 7b 3c 10BLL-6 2" 9d 3n 5BLL-7* 2d" 12b 5d 1BLL-8* 3" 12b 5d 1BLL-9* 3d" 15 6d 1BLL-10* 4" 15 6d 1
* Shipped with cover. Price includes cost of cover and body.
®
®
Aluminum Conduit Bodies, Covers and Gaskets – C StyleCat. Trade Std.No. Size A B Ctn.
BC-1-RD d" 3g 1Q 50BC-2-RD f" 4e 1w 50BC-3 1" 5c 1f 25BC-4 1b" 7b 2d 10BC-5 1d" 7b 2d 10BC-6 2" 9d 3a 5BC-7* 2d" 12b 4d 1BC-8* 3" 12b 4d 1BC-9* 3d" 15 5d 1BC-10* 4" 15 5d 1
* Shipped with cover. Price includes cost of cover and body.
TYPE BC
TYPE BLB
®
®
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E13
Thinwall Conduit Fittings (EMT)
E14 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
TYPE BT
Aluminum Conduit Bodies, Covers and Gaskets – T StyleCat. Trade Std.No. Size A B Ctn.
BT-1 d" 3g 2h 50BT-2 f" 4e 2X 50BT-3 1" 5c 2e 25BT-4 1b" 7b 3w 10BT-5 1d" 7b 3w 10BT-6 2" 9d 4 5BT-7* 2d" 12b 5A 1BT-8* 3" 12b 5A 1BT-9* 3d" 15 6m 1BT-10* 4" 15 6m 1
* Shipped with cover. Price includes cost of cover and body.
Aluminum Conduit Bodies, Covers and Gaskets – LR StyleCat. Trade Std.No. Size A B Ctn.
BLRL-1 d" 3g 2 50BLRL-2 f" 4e 2j 50BLRL-3 1" 5c 2d 25BLRL-4 1b" 7b 3c 10BLRL-5 1d" 7b 3c 10BLRL-6 2" 9d 3n 5
* Shipped with cover. Price includes cost of cover and body.
TYPE BLRL
®
Fiber Gasket
Neoprene Gasket
• Stamped aluminum(1⁄2" thru 2" sizes) ordie cast aluminum(21⁄2" thru 4" sizes).
• Steel zinc platedscrews.
• Fiber or neoprene material
Aluminum Covers with Stainless Steel Screws
Cat. Conduit Std.No. Size Ctn.
CV-1 d" 250CV-2 f" 250CV-3 1" 250CV-4 1b" - 1d" 50CV-5 2" 25CV-6 2d" - 3" 5CV-7 3d" - 4" 5
SCV-1 d" 250SCV-2 f" 250SCV-3 1" 250SCV-4 1b" - 1d" 250SCV-5 2" 100
Gaskets – CompositionCat. Conduit Std.No. Size Ctn.
GKV-1 d" 100GKV-2 f" 50GKV-3 1" 25GKV-4 1b" - 1d" 25GKV-5 2" 25GKV-6 2d" - 3" 5GKV-7 3d" - 4" 5
Gaskets – NeopreneCat. Conduit Std.No. Size Ctn.
GKN-1 d" 100GKN-2 f" 50GKN-3 1" 25GKN-4 1b" - 1d" 25GKN-5 2" 25GKN-6 2d" - 3" 5GKN-7 3d" - 4" 5
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E14
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E15
Rigid/Intermediate Grade Conduit Fittings
Snap in BlanksCat. Conduit Std.No. Size Diameter Ctn.
BL-111 d" 1Z" 1000BL-112 f" 1b" 1000BL-113 1b" 1d" 1000BL-114 1" 1m" 500BL-115 1d" 2r" 500BL-116 2" 2W" 250
• Steel• Zinc Plated
A
BBox Spacer – Die-Cast Zinc (b" space)
Cat. Conduit Std.No. Size A B Ctn.
BS-201 d" 1a" u" 500
U.L. File No. E-1275
Threadless Compression ConnectorsCat. Conduit Std.No. Size Ctn.
HC-401 d" 300HC-402 f" 150HC-403 1" 90HC-404 1b" 60HC-405 1d" 30HC-406 2" 12HC-407 2d" 12HC-408 3" 6HC-409 3d" 6HC-410 4" 6
Suggested use – rigid conduit only.U.L. File No. E-1275 d" thru 1b"
• 1⁄2"-21⁄2" – Steel• 3"-4" – Malleable Iron/Zinc plated
• 1⁄2"-21⁄2" – Steel• 3"-4" – Malleable Iron/Zinc plated
Threadless Compression CouplingsCat. Conduit Std.No. Size Ctn.
HK-401 d" 300HK-402 f" 150HK-403 1" 90HK-404 1b" 60HK-405 1d" 30HK-406 2" 6HK-407 2d" 6HK-408 3" 4HK-409 3d" 4HK-410 4" 4
Suggested use – rigid conduit only.U.L. File No. E-1275 d" thru 1b"
®
®
®
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E15
E16 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
Set Screw ConnectorsCat. Conduit Std.No. Size A B Ctn.
HC-101 d" 1a" 1a" 100HC-102 f" 1c" 1d" 50HC-103 1" e" 1m" 50HC-104 1b" 2" 2" 25HC-105 1d" 2d" 2c" 25HC-106 2" 2f" 2c" 20HC-107 2d" 3u" 3j" 10HC-108 3" 4o" 3k" 5HC-109 3d" 4l" 3m" 5HC-110 4" 5p" 4p" 5
One Set Screw or TwoTwo set screws starting at 2" Trade SizeSuggested use – rigid conduit onlyU.L. File No. E-1275 d" thru 1b"
A
B
Set Screw Connectors – InsulatedCat. Conduit Std.No. Size A B Ctn.
HC-701 d" 1a" 1a" 100HC-702 f" 1c" 1d" 50HC-703 1" e" 1m" 25HC-704 1b" 2" 2" 25HC-705 1d" 2d" 2c" 25HC-706 2" 2f" 2c" 20HC-707 2d" 3u" 3j" 10HC-708 3" 4o" 3k" 5
One Set Screw or TwoTwo set screws starting at 2" Trade SizeSuggested use – rigid conduit onlyU.L. File No. E-1275 d" thru 1b"
• Steel (concrete tight), when taped• Zinc plated
• Steel (concrete tight), when taped• Zinc plated
Set Screw CouplingsCat. Conduit Std.No. Size A B Ctn.
HK-101 d" 1a" 2u" 100HK-102 f" 1c" 2w" 50HK-103 1" 1e" 2W" 25HK-104 1b" 2" 2A" 25HK-105 1d" 2b" 3™" 25HK-106 2" 2f" 3u" 20HK-107 2d" 3k" 3C" 10HK-108 3" 4h" 4q" 5HK-109 3d" 4l" 4g" 5HK-110 4" 5h" 5c" 5
Two set screws starting at 2".U.L. File No. E-1275
A
B
• Steel (concrete tight), when taped• Zinc plated
®
A
B
®
®
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E16
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E17
Rigid/Intermediate Grade Conduit Fittings
Rigid Connector
Rigid Connectors – Set Screw Type – Die Cast ZincCat. Conduit Std.No. Size A B Ctn.
HC-201 d" 1.34 0.39 250HC-202 f" 1.44 0.45 250HC-203 1" 1.54 0.49 100
WITH INSULATED THROAT
HC-801 d" 1.34 0.39 250HC-802 f" 1.44 0.45 250HC-803 1" 1.54 0.49 100
Rigid Coupling
Rigid Couplings – Set Screw Type – Die Cast ZincCat. Trade Std.No. Size A B Ctn.
HK-201 d" 1.77 1.09 250HK-202 f" 2.06 1.34 250HK-203 1" 2.29 1.61 100
90° Short Radius Elbows – Die Cast ZincCat. Size Dimensions (in.) Shf. Ctn./No. (in.) A B Ship Qty.
HL-201-SC d" .98 .96 50/500HL-202-SC f" 1.17 1.04 25/250
USE: To join rigid or IMC conduit at right angles where lack of room prevents using a standard sweep elbow, or toterminate a run of rigid or IMC conduit at a box.UL Listing E37148
A
B
Three Piece CouplingsCat. Conduit Dimensions (in.) Shf. Ctn./No. Size A (Assembled) B Ship Qty.
EK-401 d" 1h" 1a" 100EK-402 f" 1a" 1X" 50EK-403 1" 1c" 1e" 25EK-404 1b" 1y" 2q" 25EK-405 1d" 1g" 2z" 25EK-406 2" 2" 3E" 20EK-407 2d" 2d" 3S" 10EK-408 3" 3c" 4z" 6EK-409 3d" 3e" 5q" 5EK-410 4" 3C" 5C" 5EK-411 5" 4j" 7" 1EK-412 6" 4l" 8a" 1
U.L. File No. E-1275 d" thru 4"• 1⁄2"-21⁄2" – Steel• 21⁄2"-6" – Malleable Iron• Zinc plated
®
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E17
E18 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Pull Corner Elbows – Die Cast ZincCat. Conduit Std.No. Size A B Ctn.
HL-601 d" 1.31" 1.10" 100HL-602 f" 1.60" 1.24" 50HL-603 1" 1.95" 1.59" 25HL-604 1b" 2.26" 1.97" 30
U.L. File No. E-1275
Rigid to Box with Gasket – Die-Cast ZincCat. Conduit Std.No. Size A B Ctn.
HL-611 d" 1.31" 1.09 100HL-612 f" 1.47" 1.29" 50
U.L. File No. E-1275
The T&B Hub Zinc Die Cast with Insulated Throat*Cat. Hub Std.No. Size Ctn.
H050-SC d" 100H075-SC f" 100H100-SC 1" 25H125-SC 1b" 25H150-SC 1d" 10H200-SC 2" 5H250-SC 2d" 5H300-SC 3" 2H350-SC 3d" 2H400-SC 4" 1H500-SC 5" 1H600-SC 6" 1
*Available in Nickel-Chrome plating. Consult customer service for price and delivery.*Available with PVC coating. Consult customer service for price and delivery.
• The T&B Hub with sealing ring will notfall out.
• Provides superior sealing for exceptionalwatertight performance.
H050-SC Series Hub
Rigid Couplings – Three Piece Type – Die Cast ZincCat. Trade Std.No. Size A B Ctn.
EK-201 d" 1.39 1.31 100EK-202 f" 1.53 1.58 50
®
®
Rigid/Intermediate Grade Conduit Fittings
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E18
Conduit Nipples – Die Cast Zinc – InsulatedCat. Conduit Std.No. Size A B Ctn.
HA-801 d" 0.98" 0.59" 1000HA-802 f" 1.18" 0.70" 500HA-803 1" 1.50" 0.80" 250HA-804 1b" 1.75" 1.06" 250HA-805 1d" 2.11" 1.01" 100HA-806 2" 2.61" 1.20" 40HA-807 2d" 3.13" 1.49" 25HA-808 3" 3.90" 1.65" 10HA-809 3d" 4.20" 1.68" 10HA-810 4" 4.79" 1.73" 10
U.L. File No. E-1275 d" & f“ only
Conduit Nipples – Iron/Zinc PlatedCat. Conduit Std.No. Size A B Ctn.
841-TB c" l" W" 500HA-401 d" W" n" 500HA-402 f" m" 1r" 200HA-403 1" g" 1k 100HA-404 1b" 1a" 1f" 100HA-405 1d" 1a" 2h" 50HA-406 2" 1k" 2l" 50HA-407 2d" 1b" 3" 20HA-408 3" 1d" 3g" 10HA-409 3d" 1f" 4c" 5HA-410 4" – – 5HA-411 5" – – 1HA-412 6" – – 1
U.L. File No. E-1275 c"-3d"
B
A
B
A
Conduit Nipples – Insulated Iron/Zinc PlatedCat. Conduit Std.No. Size A B Ctn.
HA-901 d" W" n" 500HA-902 f" m" 1r" 200HA-903 1" g" 1k" 100HA-904 1b" 1a" 1f" 100HA-905 1d" 1a" 2h" 50HA-906 2" 1k 2l" 50
Conduit Nipples – Die Cast Zinc – NoninsulatedCat. Conduit Std.No. Size A B Ctn.
HA-201 d" 0.98" 0.59" 1000HA-202 f" 1.18" 0.70" 500HA-203 1" 1.50" 0.80" 250HA-204 1b" 1.75" 1.06" 250HA-205 d" 2.11" 1.01" 100HA-206 2" 2.61" 1.20" 40HA-207 2d" 3.13" 1.49" 40HA-208 3" 3.90" 1.65" 40HA-209 3d" 4.20" 1.68" 40HA-210 4" 4.79" 1.73" 20
U.L. File No. E-1275 d" – 2”
®
®
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E19
Rigid/Intermediate Grade Conduit Fittings
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E19
E20 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
Conduit Nipples – Die Cast Zinc 1" LongCat. Conduit Std.No. Size A B Ctn.
HA-211 d" 1" n" 1000HA-212 f" 1" 1i" 500HA-213 1" 1" 1k" 250
U.L. File No. E-1275 d" & f“ onlyB
A
A
B
f"
Offset Nipples – Die Cast ZincCat. Conduit Std.No. Size A B Ctn.
HO-221 d" 2.60" 1.00" 100HO-222 f" 2.62" 1.32" 100HO-223 1" 2.68" 1.51" 100HO-224 1b" 2.85" 1.85" 50HO-225 1d" 2.88" 2.08" 50HO-226 2" 3.19" 2.71" 20
f offset.U.L. File No. E-1275
Locknuts – Steel/Zinc PlatedCat. Conduit Dimensions (in.) Std.No. Size A (min.) B (max.) Ctn.
LN-100-SC c" – – 1000LN-101-SC d" 0.125" 1.140" 1000LN-102 f" 0.140" 1.420" 1000LN-103 1" 0.170" 1.770" 500LN-104 1b" 0.170" 2.281" 200LN-105 1d" 0.170" 2.598" 100LN-106 2" 0.187" 3.175" 50LN-107 2d" 0.375" 3.562" 30LN-108 3" 0.375" 4.250" 25LN-109 3d" 0.438" 4.803" 25LN-110 4" 0.438" 5.402" 25LN-111 5" 0.500" 6.674" 10LN-112 6" 0.561" 7.934" 10
U.L. File No. E-1275
Thin Construction Locknuts–Steel/Zinc PlatedCat. Conduit Unit Std.No. Size Qty. Ctn.
SPLN-107 2d" 30 30SPLN-108 3" 25 25SPLN-109 3d" 25 25SPLN-110 4" 25 25
*Not U.L. Listed
A
B
®
®
®
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E20
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E21
Rigid/Intermediate Grade Conduit Fittings
Locknuts – Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Size A (min.) B (max.) Ctn.
LN-201 d" 0.125" 1.140" 2000LN-202 f" 0.140" 1.420" 1000LN-203 1" 0.170" 1.770" 1000LN-204 1b" 0.170" 2.281" 500LN-205 1d" 0.170" 2.598" 500LN-206 2" 0.187" 3.175" 200LN-207 2d" 0.375" 3.562" 100LN-208 3" 0.375" 4.250" 100LN-209 3d" 0.438" 4.803" 40LN-210 4" 0.438" 5.402" 40
CSA File No. LR-12798U.L. File No. E-1275
A
B
Locknuts–NonmetallicCat. Trade Std. No. Size “A” Dia. “B” Thd. Ctn.
LN-501 d" 1.3 d-14 100LN-502 f" 1.4 f-14 100LN-503 1" 1.7 1-11d 50
Material: Nylon 6/6Color: Gray
A
Grounding Locknuts – Malleable Iron/Zinc PlatedCat. Conduit Dimensions (in.) Std.No. Size A (min.) B (max.) Ctn.
LG-401 d" 0.125" 1.140" 100LG-402 f" 0.140" 1.420" 100LG-403 1" 0.170" 1.770" 50LG-404 1b" 0.170" 2.281" 50LG-405 1d" 0.170" 2.598" 50LG-406 2" 0.187" 3.175" 25LG-407 2d" 0.375" 3.562" 10LG-408 3" 0.375" 4.250" 10LG-409 3d" 0.438" 4.803" 50LG-410 4" 0.438" 5.402" 5
U.L. File No. E-1275
AB
Sealing Locknuts – Steel/Zinc PlatedCat. Conduit Dimensions (in.) Std.No. Size A (min.) B (max.) Ctn.
LS-101 d" 0.26" 1.12" 1000LS-102 f" 0.27" 1.37" 1000LS-103 1" 0.28" 1.75" 500LS-104 1b" 0.32" 2.06" 200LS-105 1d" 0.32" 2.37" 100LS-106 2" 0.32" 2.87" 50LS-107 2d" 0.32" 3.43" 50LS-108 3" 0.32" 4.12" 50LS-109 3d" 0.32" 4.62" 50LS-110 4" 0.32" 5.18" 25
U.L. File No. E-1275
A
B
®®
®®
®
®
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E21
E22 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
Conduit Bushings Die Cast Zinc – Insulated MetallicCat. Conduit Std.No. Size A B Ctn.
BU-801 d" 1.06 0.43 1000BU-802 f" 1.31 0.43 1000BU-803 1" 1.59 0.48 500BU-804 1b" 1.96 0.56 250BU-805 1d" 2.18 0.60 250BU-806 2" 2.68 0.56 250BU-807 2d" 3.25 0.90 50BU-808 3" 3.87 0.85 25BU-809 3d" 4.37 0.93 25BU-810 4" 5.00 0.93 10
• 105°C thermoplastic liners.• Heavy reinforced ribs.
Conduit Bushings Die Cast Zinc – Heavy Reinforced RibsCat. Conduit Dimensions (in.) Std.No. Size A (min.) B (max.) Ctn.
BU-201 d" 1.05 0.37 1000BU-202 f" 1.32 0.37 1000BU-203 1" 1.58 0.47 500BU-204 1b" 1.94 0.50 250BU-205 1d" 2.20 0.52 250BU-206 2" 2.69 0.52 250BU-207 2d" 3.23 0.85 50BU-208 3" 3.84 0.85 25BU-209 3d" 4.35 0.85 25BU-210 4" 5.02 0.85 10
Insulated Bushings – ThermoplasticCat. Conduit Std.No. Size A B Ctn.
BU-501 d" u" 1h" 400BU-502 f" u" 1∫" 400BU-503 1" l" 1l" 200BU-504 1b" l" 1C" 100BU-505 1d" l" 2i" 100BU-506 2" e" 2W" 60BU-507 2d" z" 3i" 20BU-508 3" I" 3B" 20BU-509 3d" f" 4R" 5BU-510 4" A" 4B" 5BU-511 5" 1" 6j" 5BU-512 6" 1" 7k" 5
U.L. File No. E-1275 d"-4" onlyRated 105°C
A
B
®
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E22
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E23
Rigid/Intermediate Grade Conduit Fittings
A
BBushings – Iron/Zinc Plated
Cat. Conduit Std.No. Size A B Ctn.
BU-401 d" 1o" k" 1000BU-402 f" 1b" k" 1000BU-403 1" 1l" d" 500BU-404 1b" 1n" w" 200BU-405 1d" 2$" l" 100BU-406 2" 2}" l" 50BU-407 2d" 3i" x" 30BU-408 3" 3e" A" 25BU-409 3d" 4h" B" 25BU-410 4" 4y" n" 25BU-411 5" 4y" n" 10
U.L. File No. E-1275
®
A
B
Insulated Bushings – Iron/Zinc PlatedCat. Conduit Std.No. Size A B Ctn.
BI-901 d" 1o" d" 1000BI-902 f" 1b" d" 1000BI-903 1" 1l" l" 500BI-904 1b" 1n" x" 200BI-905 1d" 2$" e" 100BI-906 2" 2}" e" 50BI-907 2d" 3r" I" 30BI-908 3" 3B" I" 25BI-909 3d" 4k" g" 25BI-910 4" 4O" 2s" 25
Grounding Bushings Die Cast Zinc – Insulated Metallic – With Aluminum Lay in Type Lug
Cat. Trade Grounding Lug Wire size Std.No. Size min. max Ctn.
BG-201 d" 14 4 500BG-202 f" 14 4 500BG-203 1" 14 4 250BG-204A 1b" 14 4 200BG-204 1b" 8 1/0 200BG-205A 1d" 11 4 100BG-205 1d" 8 1/0 50BG-206A 1" 14 4 100BG-206 2" 8 1/0 50BG-207 2d" 8 1/0 50BG-207A 2d" 6 250 MCM 50BG-208 3" 8 1/0 50BG-208A 3" 6 250 MCM 50BG-209 3d" 8 1/0 10BG-209A 3d" 6 250 MCM 10BG-210 4" 8 1/0 10BG-210A 4" 6 250 MCM 10
• 105°C Thermoplastic liners.• Heavy reinforced ribs.
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E23
E24 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
Insulated Grounding Bushings – Malleable Iron/Zinc PlatedCat. Conduit Grounding Lug Std.No. Size Wire Capacity A B Ctn.
BG-801 d" 1o" d" 500BG-802 f" #14-#4 CU 1b" d" 500BG-803 1" or 1l" l" 250BG-804 1b" #12-#4 AL 1n" x" 150BG-805 1d" 2$" e" 150BG-806 2" 2}" e" 100BG-807 2d" #14-1/0 CU 3i" I" 60BG-808 3" or #12-1/0 AL 3e" I" 30BG-809 3d" #6-250 MCM 4h" g" 30BG-810 4" CU or AL 4y" 2s" 30
U.L. File No. E-19851d"-2" Iron2b"-4" Die Cast Zinc
Grounding Bushings Die Cast Zinc – Insulated Metallic With Aluminum Lug
Cat. Trade Grounding Lug Wire size Std.No. Size min. max Ctn.
BG-801A d" 14 6 500BG-802A f" 14 6 500BG-803A 1" 14 6 250BG-804A 1b" 14 2 200BG- 805A 1d" 14 2 100BG-806A 2" 14 2 100BG-807A 2d" 14 2/0 50BG-808A 3" 14 2/0 50BG-809A 3d" 14 2/0 10BG-810A 4" 14 2/0 10BG-810B 4" 6 250 MCM 10
U.L. File No. E-19851
• For copper or aluminum bare ground wire.• 105°C thermoplastic liners.• Heavy reinforced ribs.
• RB-121 thru RB-165 – Steel.• RB-175 thru RB-187 – Malleable Iron
(concrete tight)/ Zinc Plated.
B
A
Reducing BushingsCat. Conduit Std.No. Size A B Ctn.
RB-121 f"-d" l" g" 100RB-131 1"-d" e" 1a" 50RB-132 1"-f" e" 1a" 50RB-141 1b"-d" W" 1k" 50RB-142 1b"-f" W" 1k" 50RB-143 1b"-1" W" 1k" 50RB-151 1d"-d" z" 1W" 50RB-152 1d"-f" z" 1W" 50RB-153 1d"-1" z" 1W" 50RB-154 1d"-1b" z" 1W" 50RB-161 2"-d" B" 2p" 25RB-162 2"-f" B" 2p" 25RB-163 2"-1" B" 2p" 25RB-164 2"-1b" B" 2p" 25RB-165 2"-1d" B" 2p" 25RB-175 2d"-1d" g" 2m" 25RB-176 2d"-2" g" 2m" 25RB-186 3"-2" C" 2k" 25RB-187 3"-2d" C" 2k" 25
U.L. File No. E-1275
®
®
®
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E24
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E25
Rigid/Intermediate Grade Conduit Fittings
Reducers and Enlargers – Malleable Iron/Zinc PlatedCat. Conduit Std.No. Size A B Ctn.
RB-421 f"-d" e" 1i" 100RB-432 d"-f" 1 1i" 100RB-443 1"-f" L" 1i" 50
U.L. File No. E-1275
B
B
A
Reducing Washers – Steel/Zinc PlatedCat. Conduit Diameter Std.No. Size A B C Ctn.
WA-110 d"-c" 1i" W" B" 500WA-121 f"-d" 1d" g" 1h" 500WA-131 1"-d" 1f" g" 1j" 500WA-132 1"-f" 1f" 1p" 1j" 500WA-141 1b"-d" 2i" g" 1W" 200WA-142 1b"-f" 2i" 1p" 1W" 200WA-143 1b"-1" 2i" 1R" 1W" 200WA-151 1d"-d" 2e" g" 1g" 200WA-152 1d"-f" 2e" 1p" 1g" 200WA-153 1d"-1" 2e" 1R" 1g" 200WA-154 1d"-1b" 2e" 1z" 1g" 200WA-161 2"-d" 3b" g" 2c" 100WA-162 2"-f" 3b" 1p" 2c" 100WA-163 2"-1" 3b" 1R" 2c" 100WA-164 2"-1b" 3b" 1z" 2c" 100WA-165 2"-1d" 3b" 1O" 2c" 100WA-171 2d"-d" 3b" g" 2g" 100WA-172 2d"-f" 3b" 1p" 2g" 100WA-173 2d"-1" 3b" 1R" 2g" 100WA-174 2d"-1b" 3b" 1z" 2g" 100WA-175 2d"-1d" 3b" 1O" 2g" 100WA-176 2d"-2" 3b" 2k" 2g" 100WA-181 3"-d" 4d" g" 3d" 100WA-182 3"-f" 4d" 1z" 3d" 100WA-183 3"-1" 4d" 1R" 3d" 100WA-184 3"-1b" 4d" 1z" 3d" 100WA-185 3"-1d" 4d" 1O" 3d" 100WA-186 3"-2" 4d" 2k" 3d" 100WA-187 3"-2d" 4d" 2j" 3d" 100
WA-121 thru WA-165 CSA listed.
A
B
C
®
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E25
E26 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Rigid/Intermediate Grade Conduit Fittings
One Hole Straps – Steel/Zinc PlatedCat. Screw Conduit Std.No. Size Size A B Ctn.
HS-100-SC 10 c" f" 1I" 1000HS-101 b d" 1" 1n" 500HS-102 b f" 1" 2Z" 500HS-103 b 1" 1" 2u" 250HS-104 j 1b" 1" 3p" 100HS-105 c 1d" 1i" 3u" 100HS-106 c 2" 1i" 3B" 100HS-107 k 2d" 1b" 5h" 25HS-108 d 3" 1c" 5g 25HS-109 d 3d" 1c" 6b" 10HS-110 d 4" 1c" 6g" 10
Pipe Straps – Malleable Iron/Zinc PlatedCat. Screw Conduit Std.No. Size Size A B Ctn.
HS-400 10 c" 1W" w" 500HS-401 b d" 2D" e" 500HS-402 b f" 2k" m" 500HS-403 b 1" 2g" n" 100HS-404-SC j 1b" 3j" 1o" 100HS-405 c 1d" 3f" 1a" 50HS-406 d 2" 4x" 1j" 25HS-407 e 2d" 5W" 1e" 25HS-408 e 3" 6g" 1g" 25HS-409 e 3d" 7z" 2a" 10HS-410 e 4" 8l" 2c" 10HS-411 e 5" 10s" 2e" 5
Two Hole Strap – Steel/Zinc PlatedCat. Screw Conduit Std.No. Size Size A B C Ctn.
HS-901 8 d" f" 2k" i" 1200HS-902 10 f" f" 2W" i" 900HS-903 b 1" f" 3k" i" 600HS-904 b 1b" f" 3B" i" 450HS-905 b 1d" f" 4h" i" 50HS-906 b 2" f" 4k" i" 150HS-907 b 2d" 1" 5a" b" 150HS-908 d 3" 1" 6i" b" 60HS-909 b 3d" 1" 7i" b" 60HS-910 b 4" 1" 8W" b" 60
CSA Certified
Nail Strap – Stamped Steel/Zinc PlatedCat. Rigid/MC EMT Flex Std.No. Size Size Size A B Ctn.
N-101-SC – d" c" 2q" 1Z" 1000N-102-SC d" f" d" 2j" 1r" 1000N-103-SC f" 1" – 2c" 1v" 1000
B
A
®
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E26
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E27
Rigid/Intermediate Grade Conduit Fittings
Flange Plates – Malleable Iron/Zinc PlatedCat. Conduit Dia. Depth Std.No. Size A B Ctn.
FP-401 d" 3" .625 50FP-402 f" 3c" .656 50FP-403 1" 3e" .765 50FP-404 1b" 4" .875 25FP-405 1d" 4c" .937 25FP-406 2" 4g" .843 25
A
B
j
Bolt Hole
A
B
A
B
Pipe Spacers for Rigid/Intermediate or Thinwall – Die Cast ZincCat. Conduit Std.No. Size A B Ctn.
CB-201 d" 2" 1" 1000CB-202 f" 2c" 1h" 500CB-203 1" 2f" 1j" 500CB-204 1b" 3c" 1d" 250CB-205 1d" 3m" 1e" 100CB-206 2" 4d" 2" 50
Rigid/Intermediate Space Caps – PlasticCat. Conduit Std.No. Size A B Ctn.
BR-501 d" 2v" 1y" 100BR-502 f" 2v" 1U" 100BR-503 1" 2v" 2a" 100BR-504 1b" 2v" 2V" 100BR-505 1d" 2v" 3$" 100
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E27
E28 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
• Die cast copper free aluminum construction.• Provide access for pulling, splicing, and
maintenance.• For rigid conduit/IMC applications.• U.L. Listed.• Fittings, covers and gaskets are
interchangeable with those produced byother leading manufacturers.
• Finish: Powder Coated Urethane.
TYPE ALR
Conduit Bodies, Covers and Gaskets – LR StyleCat. Trade Std.No. Size A B Ctn.
ALR-1 d" 3g 2 50ALR-2 f" 4e 2j 50ALR-3 1" 5c 2d 25ALR-4 1b" 7b 3c 10ALR-5 1d" 7b 3c 10ALR-6 2" 9d 3n 5ALR-7* 2d" 12b 5d 1ALR-8* 3" 12b 5d 1ALR-9* 3d" 15 6d 1ALR-10* 4" 15 6d 1
* Shipped with cover. Price includes cost of cover and body.
• Die cast copper free aluminum construction.• Provide access for pulling, splicing, and
maintenance.• For rigid conduit/IMC applications.• U.L. Listed.• Fittings, covers and gaskets are
interchangeable with those produced by otherleading manufacturers.
• Finish: Powder Coated Urethane.
TYPE ALL
Conduit Bodies, Covers and Gaskets – LL StyleCat. Trade Std.No. Size A B Ctn.
ALL-1 d" 3g 2 50ALL-2 f" 4e 2j 50ALL-3 1" 5c 2d 25ALL-4 1b" 7b 3c 10ALL-5 1d" 7b 3c 10ALL-6 2" 9d 3n 5ALL-7* 2d" 12b 5d 1ALL-8* 3" 12b 5d 1ALL-9* 3d" 15 6d 1ALL-10* 4" 15 6d 1
* Shipped with cover. Price includes cost of cover and body.
Rigid/Aluminum Conduit Bodies, Gaskets and Covers
Conduit Bodies, Covers and Gaskets – C StyleCat. Trade Std.No. Size A B Ctn.
AC-1 d" 3g 1Q 50AC-2 f" 4e 1w 50AC-3 1" 5c 1f 25AC-4 1b" 7b 2d 10AC-5 1d" 7b 2d 10AC-6 2" 9d 3a 5AC-7* 2d" 12b 4d 1AC-8* 3" 12b 4d 1AC-9* 3d" 15 5d 1AC-10* 4" 15 5d 1
* Shipped with cover. Price includes cost of cover and body.
TYPE AC
®
®
®
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E28
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E29
Rigid/Aluminum Conduit Bodies, Gaskets and Covers
Conduit Bodies, Covers and Gaskets – LB StyleCat. Trade Std.No. Size A B Ctn.
ALB-1 d" 3g 2h 50ALB-2 f" 4e 2k 50ALB-3 1" 5c 2f 25ALB-4 1b" 7b 3l 10ALB-5 1d" 7b 3m 10ALB-6 2" 9d 4d 5ALB-7* 2d" 12b 5b 1ALB-8* 3" 12b 5g 1ALB-9* 3d" 15 6n 1ALB-10* 4" 15 6n 1
* Shipped with cover. Price includes cost of cover and body.
TYPE ALB
TYPE AT
Conduit Bodies, Covers and Gaskets – C StyleCat. Trade Std.No. Size A B Ctn.
AT-1 d" 3g 2h 50AT-2 f" 4e 2X 50AT-3 1" 5c 2e 25AT-4 1b" 7b 3w 10AT-5 1d" 7b 3w 10AT-6 2" 9d 4 5AT-7* 2d" 12b 5A 1AT-8* 3" 12b 5A 1AT-9* 3d" 15 6m 1AT-10* 4" 15 6m 1
* Shipped with cover. Price includes cost of cover and body.
Conduit Bodies, Covers and Gaskets – LR StyleCat. Trade Std.No. Size A B Ctn.
ALRL-1 d" 3g 2 50ALRL-2 f" 4e 2j 50ALRL-3 1" 5c 2d 25ALRL-4 1b" 7b 3c 10ALRL-5 1d" 7b 3c 10ALRL-6 2" 9d 3n 5
* Shipped with cover. Price includes cost of cover and body.
TYPE ALRL
®
®
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E29
E30 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Aluminum Conduit Bodies, Gaskets and Covers
Fiber Gasket
Neoprene Gasket
• Stamped aluminum (1⁄2" thru 2" sizes) ordie cast aluminum (21⁄2" thru 4" sizes).
• Steel zinc plated screws.
• Fiber or neoprene material
Aluminum covers with Stainless Steel ScrewsCat. Conduit Std.No. Size Ctn.
CV-1 d" 250CV-2 f" 250CV-3 1" 250CV-4 1b" - 1d" 50CV-5 2" 25CV-6 2d" - 3" 5CV-7 3d" - 4" 5
SCV-1 d" 250SCV-2 f" 250SCV-3 1" 250SCV-4 1b" - 1d" 250SCV-5 2" 100
Gaskets – CompositionCat. Conduit Std.No. Size Ctn.
GKV-1 d" 100GKV-2 f" 50GKV-3 1" 25GKV-4 1b" - 1d" 25GKV-5 2" 25GKV-6 2d" - 3" 5GKV-7 3d" - 4" 5
Gaskets – NeopreneCat. Conduit Std.No. Size Ctn.
GKN-1 d" 100GKN-2 f" 50GKN-3 1" 25GKN-4 1b" - 1d" 25GKN-5 2" 25GKN-6 2d" - 3" 5GKN-7 3d" - 4" 5
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E30
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E31
Flexible Cord & Power Cable Connectors
LR 52391
StraightTrade Throat Hex
Cat. or Hub Cord Size Flat A B C Std.No. Size Range ± .03 ± .06 Max. ± .06 ± .06 Ctn.
2671† c" .125-.275 0.33 .78 2.0 .90 .46 2502690† d" .125-.275 0.33 1.00 2.3 .90 .60 1002672 d" .250-.400 0.55 1.08 2.6 1.27 .60 1002673* d" .400-.560 0.55 1.08 2.6 1.27 .60 1002691* d" .560-.690 0.54 1.32 3.0 1.57 .60 1002692* d" .660-.780 0.54 1.32 3.0 1.57 .60 1002693 f" .250-.400 0.55 1.22 2.7 1.27 .62 1002694* f" .400-.560 0.55 1.22 2.7 1.27 .62 1002674 f" .560-.690 0.79 1.34 3.0 1.57 .62 1002675 f" .660-.780 0.79 1.34 3.0 1.57 .62 1002696* f" .770-.895 0.76 1.64 3.2 1.89 .62 1002697 1" .250-.400 0.54 1.50 2.9 1.27 .77 -2698* 1" .400-.560 0.54 1.50 2.9 1.27 .77 1002695 1" .560-.690 0.98 1.60 3.1 1.89 .77 1002676 1" .660-.780 0.98 1.60 3.3 1.89 .77 1002677 1" .770-.895 0.98 1.60 3.3 1.89 .77 1002678 1" .870-1.020 0.98 1.60 3.3 1.89 .77 502699 1" .890-1.090 0.98 2.25 4.2 2.58 .77 102700 1" 1.080-1.280 0.98 2.25 4.0 2.58 .77 502702 1b" .890-1.090 1.25 2.25 4.2 2.58 .80 102703* 1b" 1.080-1.280 1.25 2.25 4.0 2.58 .80 102704* 1b" 1.270-1.470 1.25 2.25 4.0 2.58 .80 102705-TB 1b" .890-1.150 1.47 2.65 4.2 2.95 .82 102706 1b" 1.140-1.400 1.47 2.65 4.3 2.95 .82 102707* 1b" 1.390-1.650 1.47 2.65 4.3 2.95 .82 102708 2" 1.190-1.530 1.89 3.13 5.1 3.50 .84 52709 2" 1.520-1.860 1.89 3.13 4.9 3.50 .84 52710* 2" 1.850-2.190 1.89 3.13 4.9 3.50 .84 5
*Remove sufficient outer covering of cable to permit conductors to pass thru connector body.†CSA certified for factory installation.Material: Weather Stabilized Nylon, Rated at – 34°C to 105°C Temperature. For 90° Style See AS-72555.
E 13938
The BLACK BEAUTY ™ Nonmetallic Liquidtight Strain Relief Connectors
90 Degree AngleTrade
Cat. or Hub Cord Throat Hex Std.No. Size Range Size Flat A B C D Ctn.
2680† c" .125-.275 .33 .62 1.8 .90 .46 1.00 1002681 d" .250-.400 .55 .83 2.5 1.27 .60 1.35 502682* d" .400-.560 .55 .83 2.5 1.27 .60 1.35 502683 f" .560-.690 .78 1.06 2.8 1.57 .62 1.60 502684 f" .660-.780 .78 1.06 2.8 1.57 .62 1.60 502688 1" .560-.690 1.00 1.280 3.0 1.89 .77 1.90 252685 1" .660-.780 1.00 1.280 3.0 1.89 .77 1.90 252686 1" .770-.895 100 1.280 3.0 1.89 .77 1.90 252687* 1" .870-1.020 1.00 1.280 3.0 1.89 .77 1.90 25
*Remove sufficient outer covering of cable to permit conductors to pass thru connector body.†CSA certified for factory installation.
• Installs on cord by hand.• Achieves maximum pullout strength
without installation tools.• Each hub size takes a range of cord
diameters.
• Non metallic construction providescorrosion resistance.
• Weathers stabilized nylon rated at–34°C to +105°C temperature.
®
®
®
®
LR 52391E 13938®
®
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E31
E32 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Liquidtight Flexible Nonmetallic Conduit Connectors and Tubing
A
B*
D
F*
C
Standard Material/Finish• Body/Gland–Nylon-Grey• “O” Ring–Nitrate (Black)• Locknut–Nylon• Temp. Rating–80°C• Material Flammability Rating: UL94-V2
Listed/Certified by:• U.L. Listed (File # E23018)• C.S.A. (File # LR52391)
Conforms To:• Watertight requirements for Type 4
45° Connectors – Liquidtight Flex for Nonmetallic ConduitC ±.015 (0.40) Min.
A± .015 B* ±.35 Across Throat E FCat. Trade (0.40) Inch (0.90) Inch Corners Dia. D. Thread Inch (mm) Std.No. Size (mm) (mm) Inch (mm) Inch (mm) NPT. Approx. Ctn.
LT-540 c" (14.48) 2.012 (51.10) (34.39) (10.59) d-14 1.534 (38.95) 50LT-541 d" (14.48) 2.092 (53.14) (36.78) (13.97) d-14 1.590 (40.39) 50LT-542 f" (14.78) 2.452 (62.28) (44.20) (18.80) f-14 1.821 (46.25) 50LT-543 1" (18.44) 2.684 (68.17) (52.53) (23.88) 1-11/12 2.034 (51.66) 25
Connectors – Liquidtight Flex for Nonmetallic ConduitC ±.015 (0.40) Min.
A± .015 B* ±.35 Across Throat E FCat. Trade (0.40) Inch (0.90) Inch Corners Dia. D. Thread Inch (mm) Std.No. Size (mm) (mm) Inch (mm) Inch (mm) NPT. Approx. Ctn.
LT-500 c" .570 1.595 (40.51) 1.354 .417 d-14 1.880 (47.75) 100LT-501 d" .570 1.636 (41.55) 1.448 .550 d-14 1.986 (50.44) 100LT-502 f" .582 1.757 (44.63) 1.740 .740 f-14 2.212 (56.18) 50LT-503 1" .726 1.923 (48.84) 2.068 .940 1-11/12 2.508 (63.70) 50
90° Connectors – Liquidtight Flex for Nonmetallic ConduitC ±.015 (0.40) Min.
A± .015 B* ±.35 Across Throat E FCat. Trade (0.40) Inch (0.90) Inch Corners Dia. D. Thread Inch (mm) Std.No. Size (mm) (mm) Inch (mm) Inch (mm) NPT. Approx. Ctn.
LT-590 c" (14.48) 1.380 (35.05) (34.39) (10.59) d-14 1.880 (47.75) 50LT-591 d" (14.48) 1.489 (37.82) (36.78) (13.97) d-14 1.986 (50.44) 50LT-592 f" (14.78) 1.790 (45.47) (44.20) (18.80) f-14 2.212 (56.18) 50LT-593 1" (18.44) 2.104 (53.44) (52.53) (23.88) 1-11/12 2.508 (63.70) 25
®®
®®
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E32
Liquidtight Flexible Nonmetallic Conduit (Type B) Outdoor XTRAFLEX® Raceway System
Cat. No. Trade I.D. IN. O.D.IN. Std.Series Size Min. Max. Min. Max. Ctn.
LTC038GY c" .484 .504 .690 .710 100LTC050GY d" .622 .642 .820 .840 100LTC075GY f" .820 .840 1.030 1.050 100LTC100GY 1" 1.041 1.066 1.290 1.315 100LTC125GY 1b" 1.380 1.410 1.630 1.660 100LTC150GY 1d" 1.575 1.600 1.865 1.900 50LTC200GY 2" 2.020 2.045 2.340 2.375 50
Color: GrayLength: 100 ft. for LTC038GY thru LTC125GY 50 ft. for LTC150GY and LTC200GYU.L. Listed: File E95745U.L. Temperature Rating: 80°C dry, 60°C wet, 70°C oil. res. sunlight resistant, outdoor, direct burial.CSA Certified: File LR 80349-2CSA Temperature Rating: 75°C to-18°CFor use with Thomas & Betts LT38P, LT38M, LT500 series and Liquidtight Flexible Metal Conduit Fittings.Material: PVC Helix reinforcement surrounded with flexible PVC.Voltage Rating: 600V
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E33
Liquidtight Flexible Nonmetallic Conduit Connectors and Tubing
Conduit Cutter – For Nonmetallic Flexible ConduitCat.No. Description
XF-CUT For cutting NM flexible conduit up to 1"XF-BLADE Replacement blade for XF-CUT
Liquidtight Whip AssemblyCat. Conduit Wire Std.No. Size Length Gauge Ctn.
LTWHIP 12-6-10 d" 6' #10 6LTWHIP 12-4-10 d" 4' #10 6LTWHIP 34-6-8 f" 6' #8 6LTWHIP 34-4-8 f" 4' #8 6Whip with metallic fittings – one straight, one 90°
LTWM 12-6-10 d" 6' #10 6LTWM 12-4-10 d" 4' #10 6LTWM 34-6-8 f" 6' #8 6LTWM 34-4-8 f" 4' #8 6
®®
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E33
E34 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Liquidtight Fittings
Versa Ground™ LIquidtight Fittings – 90° TypeCat. Trade Std.No. Size A B C Ctn.
5351GR c 1c" 1b" 14-4 505352GR d 1l" 1k" 14-4 505353GR f 1f" 1m" 14-4 505354GR 1 2i" 2h" 14-4 25
5251GR c 1c" 1b" 14-4 505252GR d 1l" 1k" 14-4 505253GR f 1f" 1m" 14-4 505254GR 1 2i" 2h" 14-4 255251ALGR c 1c" 1b" 14-4 505252ALGR d 1l" 1k" 14-4 505253ALGR f 1f" 1m" 14-4 505254ALGR 1 2i" 2h" 14-4 25
A
B
LUG RANGE
B LUG RANGE
A
C
Versa Ground™ LIquidtight FittingsCat. Trade Std.No. Size A B C Ctn.
5341GR c 1l" 14-4 1h" 505342GR d 1g" 14-4 1c" 505343GR f 2a" 14-4 1i" 505344GR 1 2b" 14-4 1f" 25
5241GR c 1l" 14-4 1h" 505242GR d 1g" 14-4 1c" 505243GR f 2a" 14-4 1i" 505244GR 1 2b" 14-4 1f" 25
Liquidtight to Rigid External Ground AdapterCat. Trade Std.No. Size A B Ctn.
5271GR c 1q" 14-4 505272GR d 1c 14-4 505273GR f 1y" 14-4 505274GR 1 1g" 14-4 25
B LUG RANGE
A
A
UG RANGE Versa Ground™ LIquidtight FittingsCat. Trade Std.No. Size A B Ctn.
5331GR c 1d" 14-4 1005332GR d 1l" 14-4 1005333GR f 1e" 14-4 255334GR 1 2h" 14-4 50
5231GR c 1d" 14-4 1005232GR d 1l" 14-4 1005233GR f 1e" 14-4 255234GR 1 2h" 14-4 505231ALGR c 1d" 14-4 1005232ALGR d 1l" 14-4 1005233ALGR f 1e" 14-4 505234ALGR 1 2h" 14-4 50
B LUG RANGE
C LUG RANGE
B LUG RANGE
B LUG RANGE
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E34
Straight ConnectorsCat. Conduit Diameter Std.No. Size A B C Ctn.
LT-700 c" 1h" d" 1C" 100LT-701 d" 1i" T" 1O" 100LT-702 f" 1k" l" 2a" 50LT-703 1" 1f" e" 2c" 50LT-704 1b" 2k" L" 2L 25LT-705 1d" 2f" A" 2g" 10LT-706 2" 3w" A" 3j" 5
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E35
Liquidtight Flexible Metal Conduit Connectors
• 3⁄8"-1" – Steel.• 11⁄4"-2" – Malleable Iron/Zinc Plated.
• 3⁄8"-1" – Steel.• 11⁄4"-2" – Malleable Iron/Zinc Plated (with
insulated throat).
Straight ConnectorsCat. Conduit Diameter Std.No. Size A B C Ctn.
LT-100 c" 1h" d" 1m" 100LT-101 d" 1i" T" 1g" 100LT-102 f" 1k l" 2o" 50LT-103 1" 1f" e" 2s" 50LT-104 1b" 2k" L" 2x" 25LT-105 1d" 2f" A" 2A" 10LT-106 2" 3w" A" 3r" 5
CSA File No. LR-12798U.L. File No. E-1275 -c"-4"
45° Connectors – Malleable Iron/Zinc Plated (with insulated throat)
Cat. Conduit Dimensions Std.No. Size E F G I Ctn.
LT-950 c" 1h" d" 1l" 1h" 50LT-951 d" 1i" d" 1e" 1p" 50LT-952 f" 1k" l" 1g" 1i" 50LT-953 1" 1f" e" 2a" 1c" 25
45° Connectors – Malleable Iron/Zinc PlatedCat. Conduit Dimensions Std.No. Size E F G H Ctn.
LT-450 c" 1h" d" 1l" O" 50LT-451 d" 1i" d" 1e" 1" 50LT-452 f" 1k" l" 1g" 1p" 50LT-453 1" 1f" e" 2a" 1s" 25
CSA File No. LR-12798U.L. File No. E-1275
®®
®®
®®
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E35
E36 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Liguidtight Flexible Metal Conduit Connectors
90° Connectors – Malleable Iron/Zinc PlatedCat. Conduit Dimensions Std.No. Size J K L M Ctn.
LT-490 c" 1h" d" 1g" 1c" 50LT-491 d" 1i" d" 2" 1u" 50LT-492 f" 1k" l" 2i" 1y" 50LT-493 1" 1f" e" 2l" 1g" 25
CSA File No. LR-12798U.L. File No. E-1275
90° Connectors – Malleable Iron/Zinc Plated (with insulated throat)
Cat. Conduit Dimensions Std.No. Size J K L N Ctn.
LT-990 c" 1h" d" 1g" 1v" 50LT-991 d" 1i" d" 2" 1d" 50LT-992 f 1k" l" 2i" 1f" 50LT-993 1" 1f" e" 2i" 1O" 25
Straight Connectors – Die-Cast ZincCat. Conduit Diameter Std.No. Size A B C Ctn.
LT-200 c" 1.81" 0.50" 1.06" 100LT-201 d" 1.88" 0.61" 1.19" 200LT-202 f" 2.03" 0.56" 1.44" 100LT-203 1" 2.28" 0.63" 1.75" 50LT-205 1d" 2.78" 0.78" 2.75" 20LT-206 2" 3.22" 0.78" 3.53" 20LT-207 2d" 3.53" 0.84" 4.28" 1LT-208 3" 3.91" 0.88" 4.72" 1LT-209 3d" 4.04" 0.91" 5.42" 1LT-210 4" 4.16" 0.94" 5.91" 1
U.L. File No. E-1275
Straight Connectors – Die Cast Zinc (with insulated throat)Cat. Conduit Diameter Std.No. Size A B C Ctn.
LT-800 c" 1I" E" 1x" 100LT-801 d" 1I" E" 1x" 100LT-802 f" 2D" E" 1c" 100LT-803 1" 2F" H" 1G" 50
CSA File No. LR-12798
®®
®
®
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E36
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E37
Liquidtight Flexible Metal Conduit Connectors
90° Connectors – Die-Cast ZincCat. Conduit Diameter Std.No. Size A B C Ctn.
LT-290 c" 1.88" 1.38" 0.50" 100LT-291 d" 2.00" 1.41" 0.50" 100LT-292 f" 2.19" 1.66" 0.56" 100LT-293 1" 2.56" 1.88" 0.63" 50LT-294 1b" 3.00" 2.00" 0.69" 40LT-295 1d" 3.38" 2.56" 0.78" 20LT-296 2" 4.06" 3.00" 0.78" 10
U.L. File No. E-1275
90° Connectors – Die-Cast Zinc (with insulated throat)Cat. Conduit Diameter Std.No. Size A B C Ctn.
LT-890 c" 1.88" 1.38" 0.50" 100LT-891 d" 2.00" 1.41" 0.50" 100LT-892 f" 2.19" 1.66" 0.56" 100LT-893 1" 2.56" 1.88" 0.63" 50
Sealing “O” RingsCat. Std.No. Conduit Size Ctn.
SR-101 d" 500SR-102 f" 500SR-103 1" 500SR-104 1b" 250SR-105 1d" 250SR-106 2" 250
Material: Neoprene
®
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E37
E38 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Nonmetallic Sheathed Cable and Flexible Cord Connectors
All Plastic Connector for NM Cable and Flexible CordF
Cat. Size K.O. Max. Thk. Std. No. Range Size Fig. A B C D E Enclosure H Ctn.
3300 For use with 10-2, 12-2 and d" 2 1o n c .880 .795 .080 j x l 50014-2 NM cables; 18-2 and 18-3 SJ and SJO cords and 18-2 SV, SVO, SJT and SJTO cords, single or multiple; cord capacity .125-.300 diameter
3201 For use with 10-3, 12-3, 14-3, d" 1 1X 1 k .880 .795 .080 y dia. 50010-2, 12-2, 4-2 NM cables; multiple (2) 12-2 and 14-2 NM cables; single and multiple flexible cords in wire range .300 in. to .600 in.
3202 For use with 8-3 and 6-3 NM f" 1 1d 1j k 1.100 1.005 .090 g dia. 250cables; (2) 14-3, 14-2, 12-2 and 10-2 NM cables; single and multiple flexible cords in wire range .500 in. to .850 in.
Temperature Rating: 105°CCSA File Nos. 584 and 2884U.L. File No. E-23017
Figure 1 Figure 2
HHoleSize
HHoleSize
• High impact thermoplastic. U.L. 94-V1.• Features push-in design .• Captive locking wedge secures cable with single
squeeze of standard electrician’s pliers.• Provides excellent insulation, strain-relief and
high pull-out value.
Snap captive locking wedge into connector’s cavity.
Press locking wedge into cavity which locks onto cable.
Cat. No. 3201 is ideal for multiple flexible cordsand cable.
®®
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E38
Clamp Type Connector – Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Size A (min.) A (max.) B Ctn.
NC-301 c" (d"KO) 0.18" 0.64" 1.16" 1000NC-302 f" 0.41" 0.82" 1.87" 500NC-303 1" 0.34" 0.94" 2.01" 250
CSA File No. LR-12798U.L. File No. E-17583
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E39
Nonmetallic Sheathed Cable Fittings
Hit Lock ConnectorsCat. Std.No. Description Ctn.
NC501-SC d” Hit Lock Connector 500NC501DBL-SC d” Double Hit Lock Connector 500NC502-SC f" Hit Lock Connector 100SB1216-SC Twist It Bushing For Metal Studs 50
.400
.580
1.030
1.2501.000
1.120
1.300
.580
2.485
1.315
.115
NC501-SC
NC501DBL-SC NC502-SC SB1216-SC
NM Clamp Type Connector – Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Size A (min.) A (max.) B Ctn.
NC-201 c" 0.40" 0.95" 1.87" 250NC-202 f" 0.50" 1.10" 1.84" 200NC-203 1" 0.62" 1.14" 2.00" 100NC-204 1b" 0.50" 1.38" 2.28" 100NC-205 1c" 0.75" 1.61" 2.49" 50NC-206 2" 0.90" 2.04" 3.35" 50
CSA File No. LR-12798U.L. File No. E-17583
®®
®®
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E39
E40 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Nonmetallic Sheathed Cable Fittings
Connectors Clamp Type, Non-Watertight – Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Size A (min.) A (max.) B Ctn.
NC-041 1b" 0.27" 0.75" 2.02" 100NC-051 1d" 0.54" 0.95" 2.50" 50NC-061 2" 0.75" 1.12" 3.41" 40
U.L. File No. E-15170-1b"-1d"U.L. File No. E-17583-2"
Duplex Clamp Type Connector – Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Size A (min.) A (max.) B Ctn.
XC-210 c" (d" KO) 0.13" 0.65" 1.56" 250XC-211-SC c" 0.24" 0.63" 1.59" 200XC-222-SC c" 0.24" 0.63" 1.59" 200
Conduit/Cable FMC AC MCC MCI NM
MAX. SIZE c" 10/2 .565 .565 10/2MIN. SIZE c" 14/2 .425 .425 14/2
CSA File No. LR-12798U.L. File No. E-17909
For use with aluminum smooth extrudedmetal clad cable. (min. dia. .410) –(max. dia. .500)
1-1h"
NM Saddle Type Connectors – Die Cast ZincCat. Dimensions (in.) Std.No. Size A (min.) A (max.) Ctn.
XC-2200-C c" 0.12" 0.63" 500
A max.A min.
Tilt In Connector Metallic Steel – Electro-GalvanizedCat. Conduit Std.No. Size A B C D E Ctn.
NC-850 d" .050 .950 1.312 .650 8-32 x f 1000NC-851 f"-1 .050 1.250 1.750 .760 8-32 x 1 500NC-852 1-b" .062 1.625 2.125 .760 10-32 x 1 250NC-853 1-d" .062 1.970 2.500 .785 10-32 x 12 100
®
®®
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E40
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E41
Armored Cable/Flexible Metallic Conduit Fittings
Straight Connectors
Straight Squeeze Type Connectors–Malleable Iron or Stamped Steel / Zinc Plated
Cat. Conduit Unit Std.No. Size Qty. Ctn.
XC-400 c" (d" K.O.) 50 100XC-401 d" 25 100XC-402 f" 25 100XC-403 1" 25 100XC-404 1b" 5 10XC-405 1d" 10 10XC-406 2" 10 10XC-407 2d" 5 5XC-408 3" 5 5
UL File No. E-17909 d"-f"UL File No. E-1275 1"-3"c"-f"-STEEL
Straight Squeeze Type Connectors–Insulated Malleable Iron or Stamped Steel / Zinc Plated
Cat. Conduit Unit Std.No. Size Qty. Ctn.
XC-901 d" 25 100XC-902 f" 25 100XC-903 1" 25 100XC-904 1b" 5 10XC-905 1d" 10 10XC-906 2" 10 10XC-907 2d" 5 5XC-908 3" 5 5
d"-f"-STEEL
Clamp Straight Set, 90°, and Duplex Connectors
90° Angle Squeeze Type Connectors–Steel or Malleable Iron / Zinc Plated
Cat. Conduit Unit Std.No. Size Qty. Ctn.
XC-490 c" (d" K.O.) 50 100XC-491 d" 25 100XC-492 f" 25 50XC-493 1" 25 25XC-494 1b" 10 10XC-495 1d" 10 10XC-496 2" 5 5XC-497 2d" 1 1XC-498 3" 1 1
For die cast armored cable/flexible metallic conduit fittings and combination fittings refer to the Steel City® Die CastConduit Fittings section.UL File No. E-17909 c" & f"UL File No. E-1275 1"-3"c"-f"-STEEL
®
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E41
E42 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Armored Cable/Flexible Metallic Conduit Fittings
Straight Squeeze Type Connectors – Die Cast ZincCat. Dimensions (in.) Std.No. Fig. Size A (min.) A (max.) B Ctn.
XC-269 1 c" (d" KO) 0.45" 0.60" 0.96" 500XC-270 1 d" 0.74" 0.92" 1.43" 250XC-272 1 f" 0.88" 1.10" 1.59" 250XC-273 2 1" 1.10" 1.35" 1.60" 100XC-274 2 1b" 1.48" 1.65" 1.91" 100XC-275 2 1d" 1.68" 2.00" 2.12" 50XC-276 3 2" 2.12" 2.47" 2.54" 40XC-277 3 2d" 2.71" 3.08" 2.88" 10XC-278 3 3" 3.15" 3.60" 3.88" 5XC-278A 3 3d" 3.20" 4.03" 5.04" 1XC-2710 3 4" 3.15" 4.25" 5.04" 1
U.L. File No. E-17909 c" & 1"U.L. File No. E-1275 1b"-2"CSA File No. LR-12798 c"-1"
®®
Straight Squeeze Type Connectors – Insulated Die Cast ZincCat. Dimensions (in.) Std.No. Fig. Size A (min.) A (max.) B Ctn.
XC-870 1 d" 0.74" 0.92" 1.43" 250XC-872 1 f" 0.88" 1.10" 1.59" 250XC-873 2 1" 1.10" 1.35" 1.60" 100XC-874 2 1b" 1.48" 1.65" 1.91" 50XC-875 2 1d" 1.68" 2.00" 2.12" 50XC-876 3 2" 2.12" 2.47" 2.54" 10XC-877 3 2d" 2.71" 3.08" 2.88" 10XC-878 3 3" 3.15" 3.60" 3.88" 5XC-879 3 3d" 3.20" 4.03" 5.04" 1XC-8710 3 4" 3.15" 4.25" 5.04" 1
U.L. File No. E-17909-d"-f"U.L. File No. E-1275-1b"CSA File No. LR-12798
Figure 1
Figure 2 Figure 3
®®
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E42
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E43
Armored Cable/Flexible Metallic Conduit Fittings
Steel City® Cable LokCat. Size AC AC Aluminum MC (I) MC (I) Flex Std.No. Range Steel Interlocked Steel Aluminum RW Ctn.
14/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 c Steel 50XC-730 .450"/.610" 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 & ALd" K.O. 10/2 10/2 10/3 10/2 10/3
14/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 50XC-731 .450"/.610" 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 –d" K.O. 10/2 10/2 10/3 10/2 10/3
10/3 10/4 10/5 10/4 10/5 c Steel 25XC-732 .610"/.875" 8/3 8/4 – 8/3 8/4 – & ALf" K.O. 6/2 6/2
14/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 14/2 14/3 14/4 25XC-7300 .450"/.610" 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 12/2 12/3 12/4 –d" K.O. 10/2 10/2 10/3 10/2 10/3
U.L. File No. E-17909CSA File No. LR-12798
• Simple, one-piece installation with nolocknuts.
• Screw designed for exceptional pullout resistance.
• Captive screw ensures that the screw isintact for installation and resists backingout after installation.
• Corrosion-resistant, zinc-chromaticplating.
• Positive grounding.• Vibration resistant screw design.• UL listed and CSA certified.
1.Simply snap into place.No locknuts required!
2.Insert cord and twist set screw. Connectortightens as screw is set.
Simple, fast steps to installingthe Steel City® Cable Lok.
®®
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E43
E44 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Armored Cable/Flexible Metallic Conduit Fittings
Figure 1
90° Clamp Type Connectors – Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Fig. Size A (min.) A (max.) B Ctn.
XC-290 1 c" (d" KO) 0.40" 0.63" 1.80" 500XC-291 1 d" 0.65" 1.00" 2.08" 250XC-292 1 f" 0.83" 1.25" 2.27" 100XC-293 2 1" 1.27" 1.50" 2.60" 50XC-294 2 1b" 1.49" 1.85" 3.10" 30XC-295 3 1d" 1.51" 2.47" 6.05" 5XC-296 3 2" 1.51" 2.47" 6.05" 5XC-297 4 2d" 2.45" 3.50" 7.75" 2XC-298 5 3" 3.07" 4.02" 8.88" 1XC-299 4 3d" 3.63" 4.34" 12.75" 1XC-2910 4 4" 3.68" 5.17" 12.75" 1
U.L. File No. E-17909CSA File No. LR-18130M57
Insulated Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Fig. Size A (min.) A (max.) B Ctn.
XC-890 1 c" 0.40" 0.63" 1.81" 500XC-891 1 d" 0.65" 0.97" 2.18" 250XC-892 1 f" 0.77" 1.12" 2.38" 100XC-893 2 1" 1.06" 1.40" 2.87" 50XC-894 2 1b" 1.34" 1.65" 3.93" 30XC-895 3 1d" 1.51" 2.47" 6.05" 5XC-896 3 2" 1.51" 2.47" 6.05" 5XC-897 4 2d" 2.45" 3.50" 7.75" 2XC-898 5 3" 3.07" 4.02" 8.88" 1XC-899 4 3d" 3.63" 4.34" 12.75" 1XC-8910 4 4" 3.68" 5.17" 12.75" 1
U.L. File No. E-17909CSA File No. LR-12798
®®
Figure 2
Figure 3
Figure 4
Figure 5
“Threads”
“Threads”
“Threads”
“Threads”
“Threads”
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E44
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E45
Armored Cable/Flexible Metallic Conduit Fittings
Clamp Type Connector – Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Size A (min.) A (max.) B Ctn.
XC-280 c" (d" KO) 0.18" 0.64" 1.16" 1000
U.L. File No. E-17909CSA File No. LR-18130M57
Duplex Clamp Type Connector – Die Cast ZincCat. Conduit Dimensions (in.) Std.No. Size A (min.) A (max.) B Ctn.
XC-210 c" (d" KO) 0.13" 0.65" 1.56" 250
CSA File No. LR-18130M57
For use with metal clad cable.
A max.A min.
Snap-In Connector for Flexible Metal Conduit – 105°C RatedCat. K.O. Unit Std.No. Conduit Size Size Qty. Ctn.
100-TB c" d" 50 500100BP c" d" 250 1000
BX Flex Bushings – Anti-ShortCat. Fits Standard Unit Std.No. Cable Range Size Qty. Ctn.
IT-100-SC 14/2-14/3-12/2 0 100 100IT-101 14/4-12/3-6/1-4/1 1 100 35IT-102 12/4-10/2-10/3-2/1 2 50 50IT-103 10/4-8/2-8/3-1/1 3 50 50IT-104 8/4-6/2-6/3-4/2-4/3-6/4 4 50 50
For die cast armored cable/flexible metallic conduit fittings and combination fittings refer to the Steel City® Die CastConduit Fittings section.Ordered by Bags
Cable RangeCat. Continuous Corrugated and Corrugated Aluminum Smooth Extruded Std.No. min. dia. max. dia. min. dia. max. dia. Ctn.
XC-280 – .510" .345" .525" 1000XC-210 – – .410" .500" 250
1-1h"
®®
®
• No locknut required.• No special tools required.• High impact thermoplastic with steel insert.
• Packed in polybags.• Available bulk packed-10,000 per carton.• Plastic.
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E45
BX Flex Connectors, Saddle Type – Die Cast ZincCat. Dimensions (in.) Std.No. Size A (min.) A (max.) B Ctn.
XC-2200-C c" 0.12" 0.63" 0.98" 500
E46 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Armored Cable/Flexible Metallic Conduit Fittings
XC-220
Straight Set Screw Connectors – Die Cast Zinc – NoninsulatedCat. Dimensions (in.) Std.No. Size A (min.) A (max.) B Ctn.
XC-220 c" (d" KO) 0.38" 0.63" 0.84" 1000
XC-221 d" 0.74" 0.94" 1.46" 250
XC-821 d" 0.74" 0.94" 1.46" 250
XC-220 and XC-221: U.L. File No. E-17909 c"U.L. File No. E-1275 d"
XC-821: U.L. File No. E-1275 d"A max.
A min.
A max.A min.
B A max.A min.
B
XC-221XC-821
Screw-In Connectors – Die Cast Zinc – NoninsulatedCat. Dimensions (in.) Std.No. Size A B Ctn.
XC-240 c" (d" KO) 1.31" 0.92" 500XC-241 d" 1.38" 0.92" 500XC-242 f" 1.62" 1.12" 125XC-243 1" 1.94" 1.37" 125XC-244 1b" 2.12" 1.75" 50XC-245 1d" 2.31" 2.13" 50XC-246 2" 2.58" 2.67" 50
U.L. File No. E-1275CSA File No. LR-18130M57 c"-d"
Screw-In Connectors – Die Cast Zinc – InsulatedCat. Dimensions (in.) Std.No. Size A B Ctn.
XC-840 c" (d" KO) 1.31" 0.92" 500XC-841 d" 1.38" 0.92" 500XC-842 f" 1.62" 1.12" 125XC-843 1" 1.94" 1.37" 125XC-844 1b" 2.12" 1.75" 50XC-845 1d" 2.31" 2.13" 50XC-846 2" 2.58" 2.67" 50
U.L. File No. E-1275CSA File No. LR-18130M57 c"-d"
A
B
Screw-In Couplings – Die Cast ZincCat. Dimensions (in.) Std.No. Size A B Ctn.
XK-241 d" 1.81" 0.92" 250XK-242 f" 2.09" 1.12" 250XK-243 1" 2.41" 1.37" 125XK-244 1b" 2.75" 1.81" 50XK-245 1d" 3.05" 2.12" 50XK-246 2" 3.28" 2.67" 50
U.L. File No. E-1275
A
B
®
®
®
®®
®
A
B
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E46
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E47
Cable Straps, Cable Caps
Service Cable Straps – One HoleCat. Fits Shelf Ship Std.No. Cable Ctn. Case Ctn.
SE100 3#8, 3#6, 3#4 100 1000 1000SE101 3#3, 3#2 100 1000 1000SE102 3#1, 3#0, 3#1/0, 3#2/0 25 250 250SE103 3#3/0, 3#4/0 25 250 250
Service Cable Caps – OvalCat. Fits Dimensions (Inches) Std.No. Cable A B C Ctn.
50130 To 2/0-3 5.00 3.31 4.75 1050130A To 4/0-3 6.75 4.62 6.00 5With Split Insulator
SC1000 3#3-2 2.37 2.12 2.25 25SC2001 3#3/0-4/0 4.93 3.12 3.75 10
Extra Large Body for Additional Wiring Space.
Service Cable Straps – Two HoleCat. Fits Shelf Ship Std.No. Cable Ctn. Case Ctn.
SE900 3#8, 3#6, 3#4 100 1000 1000SE901 3#3, 3#2 100 1000 1000SE902 3#1, 3#0, 3#1/0, 3#2/0 25 250 250SE903 3#3/0, 3#4/0 25 250 250
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E47
E48 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Service Entrance Fittings
Aluminum Service Caps – Clamp Type for Rigid/Intermediate or Thinwall
Cat. Conduit Std.No. Size No. Hole Size Ctn.
SH-101 d" 4 ∫" 50SH-102 f" 5 2(c") 3(u") 50SH-103 1" 5 2(k") 3(d") 10SH-104 1b" 5 2(N") 3(e") 10SH-105 1d" 6 2(x") 1(k") 3(f") 5SH-106 2" 6 2(f") 3(1") 1(w") 5SH-107 2d" 7 3(g") 1(1") 3(1j") 1SH-108 3" 7 4(1a") 3(1f") 1SH-109 3d" 4 4(1f") 2(a") 1SH-110 4" 4 4(1f") 2(1a") 1
CSA File No. LR-12798U.L. File No. E-22753
A
BService Entrance Fittings
Cat. Trade Std.No. Size A B Ctn.
ASLB-1 d" 3h 1l 50ASLB-2 f" 3l 1f 50ASLB-3 1" 4b 2i 25ASLB-4 1b" 5d 3 10ASLB-5 1d" 6b 3b 10ASLB-6 2" 6f 4 5DASLB-1 d" 3h 1l 24DASLB-2 f" 3l 1f 20DASLB-3 1" 4b 2i 8
Service Entrance Fittings – Standard d" - 2"Cat. Trade Std.No. Size A B Ctn.
ASLB-1 d" 3h 1l 50ASLB-2 f" 3l 1f 50ASLB-3 1" 4b 2i 25ASLB-4 1b" 5d 3 10ASLB-5 1d" 6b 3b 10ASLB-6 2" 6f 4 5
Service Entrance Fittings – Standard d" - 4"Cat. Trade Std.No. Size A B Ctn.
SALB-7 2d" 3h 1l 50SALB-8 3" 3l 1f 50SALB-9 3d" 4b 2i 25SALB-10 4" 5d 3 10
TYPE LB
®
®
®
®
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E48
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E49
Grounding Clamps/Connectors
Ground Clamps – Die Cast Zinc Alloy for Armored Ground WireCat. Conduit Std.No. Conduit Size Ctn.
GA-203 d"; f"; 1" 250
U.L. File No. E-10661
Ground Clamps – Die Cast Zinc, Brass ColoredCat. Conduit Std.No. Conduit Size Ctn.
GC-203-B d"; 1" 200
Two-screw ground connection forarmored ground wire.
Water-Tight ConnectorsCat. Trade Rubber Grommet Opening Std.No. Size Fits Cable A B Ctn.
WT-203A 1" 3#8 .500 .750 100WT-203B 1" 3#6 .563 .844 100WT-203C 1" 3#4 .625 .938 100WT-204A 1b" 3#3 .625 1.000 50WT-204B 1b" 3#2 .580 .960 50WT-204C 1b" 3#1 .660 1.090 50WT-204D 1b" 3#1/0 .750 1.125 50WT-205A 1d" 3#1/0 & 3#2/0 .735 1.240 20WT-205B 1d" 3#2/0 & 3#3/0 .875 1.375 20WT-205C 1d" 3#2/0 & 3#3/0 .938 1.438 20WT-206A 2" 3#1/0 & 3#2/0 .735 1.240 20WT-206B 2" 3#2/0 & 3#3/0 .875 1.375 20WT-206C 2" 3#2/0 & 3#3/0 .938 1.438 20WT-206D 2" 3#4/0 .890 1.550 20WT-206E 2" 3#4/0 1.063 1.688 20
For Underground Feeder Cable
UF-201 d" 2#14 .210 .440 250UF-202 f" 3#14 .220 .660 250
• For Type SE, Style U, Flat; 2 InsulatingConductors, 1 Bare.
A
B
®
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E49
E50 © 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Gutter Connectors/Cable Protector and Cable Clip
Gutter Connectors
1-2o"
A
3 PiecesSteel/Zinc Plated
Locknut
Spacer
Fitting
1"
1"
1a"
c"
Cable ProtectorCat. Std.No. Description Ctn.
CP-1 Steel 100
1c"
1l"
Cable ClipCat. Std.No. Description Ctn.
NS-100 Steel 1000
Gutter Connectors StraightCat. Conduit Std.No. Size A Dia. Ctn.
UC-101 d" 1a" 250UC-102 f" 1k" 250UC-103 1" 1f" 150UC-104 1b" 2a" 90UC-105 1d" 2d" 50UC-106 2" 2n" 30
U.L. File No. E-1275
Replaces conventional method ofnipple, locknuts and bushings tointerconnect panel boxes and othertype enclosures to troughs or gutters.Gutter connectors provide automaticuniform 1" spacing with no threadsshowing.Conventional installation requires that anipple be used with double locknuts at
both ends or with a bushing andlocknut at each end. Also, when usingtwo or more nipples, time is consumedadjusting the nipples for straightalignment of the enclosure. Gutterconnectors eliminate these timeconsuming methods. The three piececonnector requires the tightening ofonly one locknut.
®
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E50
© 2003 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E51
Beam Clamps for Mounting Pipe or Conduit
Conduit/Pipe to Beam ClampsDimensions in Inches
Cat. O.D. of Conduit Nom. Conduit or Std.No. & Size or Pipe Pipe Size Ctn.
RCS Clamp – Steel
RCS-1/2 .840 d 50RCS-3/4 1.050 f 50RCS-1 1.315 1 50RCS-1-1/4 1.660 1b 50RCS-1-1/2 1.900 1d 50RCS-2 2.375 2 50
RC Clamp – Malleable Iron
RC-3/8 .675 c 50RC-1/2 .840 d 50RC-3/4 1.050 f 50RC-1 1.315 1 50RC-1-1/4 1.660 1b 50RC-1-1/2 1.900 1d 50RC-2-SC 2.375 2 50RC-2-1/2 2.875 2d 25RC-3 3.500 3 25RC-3-1/2 4.000 3d 25RC-4-SC 4.500 4 20
EC Clamp – Malleable Iron
EC-1/2 .840 d 50EC-3/4 1.050 f 50EC-1 1.315 1 25EC-1-1/4 1.660 1b 25EC-1-1/2 1.900 1d 25EC-2 2.375 2 25EC-2-1/2 2.875 2d 10
PC Clamp – Malleable Iron
PC-3/8 .675 c 50PC-1/2 .840 d 50PC-3/4 1.050 f 50PC-1 1.315 1 50PC-1-1/4 1.660 1b 25PC-1-1/2 1.900 1d 25PC-2 2.375 2 25PC-2-1/2 2.875 2d 25PC-3 3.500 3 10PC-3-1/2 4.000 3d 10PC-4 4.500 4 10
• For mounting pipe or conduit at right anglesto the beam.
• SS316 Suffix Stainless Steel.• HDG Suffix – Hot Dip Galvanized.
RCS Series
• For mounting pipe or conduit verticallyacross the beam.
• HDG Suffix – Hot Dip Galvanized.
• For mounting pipe or conduit parallel to thebeam.
• HDG Suffix – Hot Dip Galvanized.
EC Series
PC Series
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E51
E52 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Conduit and Pipe Hangers
6H Series Conduit and Pipe Hangers – Without BoltSize (in.)
Dimensions (in.)Cat. Rigid Conduit Load Std.No. or Pipe EMT A B C D (dia.) Rating Ctn.
6H0 c - d d f .045 1y s 500 1006H0-T c - d d f .045 1B s 500 1006H1 f f g .045 1O s 500 1006H1-T f f g .045 2s s 500 1006H2 1 1 g .045 2c s 500 1006H2-1/2 – 1b g .045 2z s 500 1006H3-SC 1b 1d g .045 2g s 500 100
6H4 1d – 1 .071 3c X 500 1006H5 2 2 1b .071 3C X 500 506H6 2d – 1b .071 4s X 500 506H7 3 – 1b .071 5i X 500 256H8 3d – 1b .071 5k X 500 256H9 4 4 1b .071 5g X 500 10
* Add SS suffix to part number for stainless steel.Load rating is 500 lbs. with a safety factor of 3. Available with or without closure bolt. Standard finishes: electrogalvanizedand Type 302 Stainless Steel.
For hanging conduit (rigid or EMT) and pipe.The 6H series hangers are fast, easy andeconomical to use. May be fastened directlyto a #500 beam clamp through a hole in thebase of the hanger by means of a 1⁄4-20 stovebolt or suspended on 1⁄4" hanger rod.
Without Bolt
6H Series Conduit and Pipe Hangers – With BoltSize (in.)
Dimensions (in.)Cat. Rigid Conduit Load Std.No. or Pipe EMT A B C D (dia.) Rating Ctn.
6H0-B c - d d f .045 1y s 500 1006H0-TB c - d d f .045 1B s 500 1006H1-B f f g .045 1O s 500 1006H1-TB f f g .045 2s s 500 1006H2-B 1 1 g .045 2c s 500 1006H2-1/2-B – 1b g .045 2z s 500 1006H3-SC-B 1b 1d g .045 2g s 500 100
6H4-B 1d – 1 .071 3c X 500 1006H5-B 2 2 1b .071 3C X 500 506H6-B 2d – 1b .071 4s X 500 506H7-B 3 – 1b .071 5i X 500 256H8-B 3d – 1b .071 5k X 500 256H9-B 4 4 1b .071 5g X 500 10
* Add SS suffix to part number for stainless steel. (not UL listed.)Load rating is 500 lbs. with a safety factor of 3. Available with or without closure bolt. Standard finishes: electrogalvanizedand Type 302 Stainless Steel.
6HWithout bolt.
6H-BWith bolt and hex nut.
6H-TThreaded without bolt.
6H-TBThreaded with bolt.
®
®
Beam ClampCat. Std.No. Size Tapped Ctn.
BC1-TB 1 b-20 250
BC2-TB 2n c-16 –
Material: SteelFinish: Zinc Plated
All Steel City 6H Hanger Bolts include acombination Slot-Phillips Head.
E
Stee
l Cit
y®
412034.E01 5/7 5/7/03 4:52 PM Page E52
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com E53
Beam Clamps/Threaded Rod/Rod Coupling
Beam Clamps – Malleable Iron, Electroplated FinishBase Size Jaw Tapping
Cat. Inches Opening of Base Load Std.No. A B Inches and Back Holes Rating‡ Ctn.
510 B 1a e b-20 400 100511-SC B 1a e 10-24 400 100500-SC 1 1b n b-20 450 50509 1 1b n 10-24 375 100501 1d 1e g j-18 800 50502 2 2 1 c-16 1300 50503-SC 2e 2d 1 d-13 1300 20507 2d 2c 1c d-13 1700 20508 2d 2c 2a d-13 1700 10
‡Safety Factor of 3.Loan Ratings based on bottom hole of Beam Clamp.CSA File No. LR-52208
R-Series Continuous Thread Rod – GalvanizedData for Pressure Piping
Cat. Rod Ultimate‡ Root Area Nominal Max. Safe Std.No. Size Load in Lbs. Thread Pipe Size Load at 450° Ctn.
R628-6 ft. b-20 900 .027 300R638-6 ft. c-16 1900 .068 f" to 2" 610 150R648-6 ft. d-13 3500 .126 2d" to 3d" 1130 60R1028-10 ft. b-20 900 .027 500R1038-10 ft. c-16 1900 .068 f" to 2" 610 250R1048-10 ft. d-13 3500 .126 2d" to 3d" 1130 100
‡Load Ratings based on safely factor of three.
H-195 Steel Rod CouplingCat. Dimensions in Inches Std.No. Rod Size A B Ctn.
H-195-1/4 b f c 1000H-195-3/8 c 1 d 500H-195-1/2 d 1 e 500H-195-5/8 e 1d f 50
E
Steel City®
412034.E01 5/7 5/7/03 4:52 PM Page E53
You’ve told us what your customers say ... how they work ... and what they need for a better,faster, easier job. And we’ve used your feedback tomake Steel City® the most versatile and trusted
brand in the industry! And now the line is bigger and
stronger than ever. Steel City® boxesnow include exclusive new features tohelp simplify and speed up installations.We’ve upgraded the extensive line of
Steel City Fittings for added convenience and reliability. And we’ve added a new line of over 600Steel City Spring Steel Fasteners that meet all thecurrent UL test requirements.
Thomas & Betts and you – together we’re building on a century of trust. For technical information about any product in the Steel City line, call 1-888-862-3289.