ComfortLink II / AccuLink Zoning. 08/25/2011. ComfortLink II / AccuLink Zoning. Launch date is 08/29/11 Approved applications for initial release: Trane/American Standard Indoor unit with a variable speed blower PWM control of the indoor blower is required for the 1 st release - PowerPoint PPT Presentation

Citation preview

Page 1: ComfortLink II / AccuLink Zoning

08/25/2011

ComfortLink II / AccuLink Zoning

Page 2: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/112

• Launch date is 08/29/11

• Approved applications for initial release:– Trane/American Standard Indoor unit with a variable speed blower

PWM control of the indoor blower is required for the 1st release– Wired sensors

Wireless sensors are currently being tested and are scheduled to release mid to late October

• Non Approved applications for initial release:– Bypass control scheme

Since the software to support bypass resides in the Zone Panel, a Zone Panel change will be required

ComfortLink II / AccuLink Zoning

Page 3: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/113

Communicating System

ComfortLink II / AccuLink Zoning

Page 4: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/114

Non Communicating System

ComfortLink II / AccuLink Zoning

Page 5: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/115

Hybrid System

ComfortLink II / AccuLink Zoning

Page 6: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/116

TZONE950AC52ZAAComfortLink II

XL950

AZONE950AC52ZAAAccuLink

Platinum ZV

ComfortLink II / AccuLink Zoning

Page 7: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/117

• A 950 control is required for all zoning applications– The 950 control is the central control point for all system functionality,

including zoning

• Version 2.0 software is required for zoning operation All 950 controls built after 9/22/11 will have version 2.0 software Zoning cannot be enabled with software versions 1.0 & 1.1 Existing inventory of version 1.0 and 1.1 controls must be sold through before

version 2.0 software will be available

• Control software can be updated two ways:– Internet upgrade on control

Requires valid wireless connection and SD card– Software download to SD card via Trane.com or Americanstandardair.com

XL950 / Platinum ZV Control

Page 8: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1115

• New Features (2.0)– Zoning capability (with Zone Panel and Wired Sensors)

All zoning related features are documented in the Zone Panel IG– Schlage Link compatible (non-zoning only)

Training presentation is loaded on FSR Forum– Improved diagnostics

• Improvements– Photo Album screensaver is now persistent after a power cycle– CFG.004.00 (No Humidity Sensor) is now a Normal alert and

diagnostics have been corrected– Weather feature has been completely re-architected to improve

connectivity

XL950 / Platinum ZV Control

Page 9: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1116

• ZZSENSAL0400A is a non-display temperature sensor only

• ZZSENSAL0400A is the same part that is used with the TCONT402 thermostat

• When using a ZZSENSAL0400A as a zone sensor, set point and mode can be adjusted at 950 control

ZZSENSAL0400A Wired Indoor Temperature Sensor

Page 10: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1117

• The sensor requires two wires which are connected to the corresponding slot on the Zone Panel

• Zone 1 can be controlled by either the onboard sensor of the 950 control or a wired sensor

• ZZSENSAL0400A does not have humidity sensing capability

ZZSENSAL0400A Indoor Temperature Sensor

Page 11: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1118

ComfortLink II / AccuLink Zoning

Page 12: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1119

ZZONEPNLAC52ZAA Zone Panel Kit

Page 13: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1120

Zone Panel Connections

Page 14: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1121

Zone Panel Connections

Page 15: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1122

Zone Panel Connections

Page 16: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1123

Zone Panel Connections

Page 17: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1124

Zone Panel Connections

Page 18: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1125

Zone Panel Connections

Page 19: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1126

Zone Panel Connections

Page 20: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1127

Zone Panel Connections

Page 21: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1128

Zone Panel Connections

Page 22: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1129

Zone Panel Connections

Page 23: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1130

Zone Panel User Interface

• User Interface Menu– System Status– Zone Status– Information– Alerts

• User Interface is the best place to get up-to-date external duct static– Value displayed on 950 control is

not updated unless “Refresh” button is pressed

Page 24: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1131

• All zoning instructions will be included in the Zone Panel literature

• This includes the steps required to setup a zoning system in the 950 control

Installation Guide

Page 25: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1132

There are three options for zone dampers:•Round•Round Retrofit (slide in)•Rectangular

Zone Damper

Page 26: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1133

The position indicator provides an easy reference point to view damper movement

Electrical connections. The connections “COM, PO & PC” are the same between the zone panel and actuator

Damper release button. Press this button releases the gears and allow the damper to be adjusted manually

The part number and power consumption is listed on each actuator

Zone Damper Actuator

Page 27: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1134

XL950 / Platinum ZV Control

• The 950 control has advanced diagnostic capability– All critical alerts will be displayed on the home screen and flash a

“RED” icon on the shortcut bar Critical Alerts disable heating/cooling operation

– All major alerts will display a “Yellow Icon” on the shortcut bar of the 950 control Major Alerts disable some functionality but heating/cooling operation is

possible– Normal Alerts are logged but not displayed to the end consumer

Normal Alerts are fault conditions that may interfere with system operation but will clear on there own

Page 28: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1135

Advanced Diagnostics

• Diagnostic Screen will display all alerts regardless of severity– Current Alerts (active alerts only)– Alert History (alerts which have been negated)

• In the Diagnostic screen all alerts will have a Problem Description and Possible Cause listed– Current Alerts will display the time the alert was asserted– Alert History will display the time the alert was cleared

Page 29: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1136

Advanced Diagnostics

• New Alert Messages – There are certain alerts which disable zoning, but heating/cooling

operation will be maintained– These alerts are categorized as Major since heating/cooling operation is

still possible (examples below) SOP.04.00 Indoor Temperature Sensor Fault SOP.04.50 Discharge Temperature Sensor Fault SOP.04.54 Four DTS trips within 1 hour

Page 30: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1137

Advanced Diagnostics

• Disable Zoning continued…– Heating/cooling operation will be controlled by the temperature

sensor in the largest zone (highest zone size/weight)– All dampers will be driven to full open position– These alerts will display a pop-up on the zones which are disabled

and also indicate which zone is controlling heating/cooling operation

– Once the alert condition is cleared the system will automatically revert back to zoning operation

Page 31: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1138

Advanced Diagnostics

Page 32: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1139

Advanced Diagnostics

Page 33: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1140

Advanced Diagnostics

Page 34: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1141

Advanced Diagnostics

• New Alert Messages– There are certain alerts which disable heating/cooling operation– These alerts are categorized as Critical since heating/cooling

operation is not allowed (examples below) ERR91 Communication Fault ERR126 Communication device missing/changed

Page 35: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1142

Advanced Diagnostics

Page 36: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1143

Advanced Diagnostics

Page 37: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1144

Summary Table

• In the previous example we showed an Err.126.00 which defeated system operation

• Err.126.00 indicates either equipment missing or changed

• A Summary Table has been added which will list all communicating devices and the current status of each device to assist in troubleshooting

Page 38: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1145

Summary Table

• Here the Summary Table shows three communicating devices, two are online and one is offline

• The offline device is what created the Err.126.00

• Two Zone Expanders have been created with the same serial number because the zone dip switch was changed after initial power up

Page 39: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1146

Summary Table

• Once the dip switch is changed to the correct position the online/offline status changed

Page 40: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1147

Summary Table

• Select the “Offline” device and press “Remove Selected Offline Devices”

Page 41: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1148

Summary Table

• The “Offline” device has now been removed

• The Err.126.00 will now be cleared and system operation will resume

• The Summary Screen allows for “Offline” devices to be removed without using the “Restore Factory Settings” which clears all settings

Page 42: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1149

Look for even more advanced diagnostics in revision 2.1 software

Page 43: ComfortLink II / AccuLink Zoning

Zoning Webex 08/25/1150

Questions?