10
User manual User manual Page 1 Fix the timer to a wall in a covered location, sheltered from weather and splashing water; ambient temperature between 0 and 50 °C. Do not install the timer outdoors or in underground valve box. Before connecting the timer to the electrical power supply, install the 9V backup battery, which will ensure that the clock setting and program- me data will not get lost in case of a mains power failure. Open the snap-fit cover of the battery pocket. Pull out the cable (and the old battery, in case of a replacement). Connect or replace the battery. Reposition the cable and the battery in the pocket and close the cover. For Cometa 4 Zone (p/n): 8014 For Cometa 6 Zone (p/n): 8016 For Cometa 4 Zone (p/n): 8014 For Cometa 6 Zone (p/n): 8016 Cometa Cometa 1 1 2 2 3 3 1 1 2 2 3 3 a 6mm 6mm TSP 4x30 b a a a b b b c OK! NO! min. 0°C max. 50°C 2 - 3 sec. 9 V Alcaline

Cometa User manual - claber.co.uk · Claber to pump 220 V A. Page 3 Having completed the installation of the timer, the clock and calendar must be set: time, year, day and month

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

  • User manualUser manualPage 1

    Fix the timer to a wall in a covered location, sheltered from weather and splashing water; ambient temperature between 0 and 50 °C. Do not install the timer outdoors or in underground valve box.

    Before connecting the timer to the electrical power supply, install the 9V backup battery, which will ensure that the clock setting and program-me data will not get lost in case of a mains power failure. Open the snap-fit cover of the battery pocket. Pull out the cable (and the old battery, in case of a replacement). Connect or replace the battery. Reposition the cable and the battery in the pocket and close the cover.

    For Cometa 4 Zone (p/n): 8014For Cometa 6 Zone (p/n): 8016

    For Cometa 4 Zone (p/n): 8014For Cometa 6 Zone (p/n): 8016

    CometaCometa

    11 22 33

    11 22 33

    aa

    6mm

    6mm

    TSP 4x30bb

    aaaa aa

    bb

    bbbb

    cc

    OK!

    NO!

    min. 0°C

    max. 50°C

    8 910 1

    1 12MV

    8 910 1

    1 12VMV

    8 910 1

    1 12MV

    8 910 1

    1 12VMV

    8 910 1

    1 12MV

    8 910 1

    1 12VMV

    2 - 3 sec.

    9 V

    Alcalin

    e

  • Page 2

    Having laid the protective conduit for the valve cables (from the valves to the junction box), proceed with the installation of all the cables, bearing in mind that:1) the terminals common to all the valves (including the Master Valve) are located together in the junction

    box; hence the connection to the timer is made with a single common cable 2) the recommended cross section for all cables is 1.5 mm2, over lengths shorter than 350 m; section size

    must be increased for longer lengths3) the solenoid valves and relays operate at 24 V AC4) if there is a pump installed, this must be connected only through a 150-200mA relay, which will operate a

    solenoid switch 5) remove the cable cover, unscrewing the two 2.9x13 self-tapping screws6) route all the cables coming from the conduit through the slot provided in the timer housing7) fit the timer onto the wall bracket8) proceed to make the following connections, baring the relative wires of at least 15 mm

    - the wire common to each valve and the Master Valve, coming from the junction box, to terminal “C” - the second wire of each valve to automatic terminals 1 to 4 (for Cometa 4 zone timer) or terminals 1 to 6

    (for Cometa 6 zone timer) - the second wire of the master valve, or of the pump control relay, to terminal “MV”

    9) attach the two wires of the transformer cable, bared of at least 15 mm, to terminals “AC” and “AC”10) fit the cover and secure with the two screws11) plug the 220 / 24V transformer into the AC mains power socket

    For Cometa 4 Zone (p/n): 8014Per Cometa 6 Zone (p/n): 8016

    CometaCometa User manualUser manual

    111 2 3 4 5 6 C RMV AC AC

    Co

    mm

    on

    max

    350

    m (

    cro

    ss s

    ecti

    on

    1.5

    mm

    2 )

    jun

    ctio

    n b

    ox

    MV

    Claberrelay

    Line valves

    no

    RS

    Rain Sensor

    (optional)

    1 2 3 4 5 6

    1 2 3 4 5 6

    B

    RelèClaber

    to pump

    220 V

    A

  • Page 3Having completed the installation of the timer, the clock and calendar must be set: time, year, day and month. The internal calendar, which runs until 2057, will show the day of the week corresponding to the current date: setting the date 11/01/2011, for example, the number 3 will be displayed, corresponding to Tuesday (number 1 denotes Sunday).To set the time:- press button B and keep it pressed for at least 5 seconds (to activate the SET-TIME function )- press ENTER to activate the setting procedure- use the arrows to set the time- press ENTER to confirm

    To set the year, day and month:- press button B; the symbol will appear in the display, with the default year- press ENTER to activate the setting procedure- use the arrows to select the year- press ENTER to confirm the year and activate the day and month setting function (the message OK continues

    to be displayed, and the cursor blinks on month 7)- use the arrows to select the day and month (press the button and keep it pressed until the cursor is positio-

    ned on the number of the month and the current day)- press ENTER to confirm- press EXIT (buttons A and B)

    For Cometa 4 Zone (p/n): 8014For Cometa 6 Zone (p/n): 8016

    CometaCometa User manualUser manual

    11 22 33

    11 22 33

    aa

    5 sec.

    bb bb

    bb

    aaaa

    bbbb

    aa

    cc cc

    aa

  • Page 4

    For Cometa 4 Zone (p/n): 8014For Cometa 6 Zone (p/n): 8016

    For Cometa 4 Zone (p/n): 8014For Cometa 6 Zone (p/n): 8016

    CometaCometa

    SETTING PROGRAMME A - DURATION- press button A once: the symbol appears, the cursor blinks on valve 1 of the 4 or 6 valves available, and

    the relative duration is displayed (0:10)- press ENTER to activate the line 1 duration setting procedure- use the arrows to select the duration (e.g. 0:15)- press ENTER to confirm the setting- press the right arrow to select the next valve (up to 4 for the Cometa 4 zone timer, up to 6 for the Cometa 6 zone)- repeat the same sequence of steps for all the valves. To deselect a valve, if required, simply set the duration

    to OFF, pressing the left arrow

    User manualUser manual

    44 55 66

    x 1

    bb bb bb

    aa x 30

    month

    day

    dd dddd

    x 1

    x XXcc

    aa

    cccc

    ee

    aa

    11 22 33

    aa aa

    bb bb bb

    aa

  • Page 5

    For Cometa 4 Zone (p/n): 8014For Cometa 6 Zone (p/n): 8016

    For Cometa 4 Zone (p/n): 8014For Cometa 6 Zone (p/n): 8016

    CometaCometa

    SETTING PROGRAMME A - START TIMES- press button A once: the symbol appears, the cursor blinks on the first start of the four available - press ENTER to activate the setting procedure- use the arrows to set the start time- press ENTER to confirm the setting- To set another start time, select 2-3-4 with the arrows and repeat the same sequence of steps. To deselect a

    start, simply set the time to OFF.

    User manualUser manual

    44 55 66

    dd

    11 22 33

    aa

    bb bb

    aa

    bb bb

    aa

    cc

    dd

    cc x 10

    aa

    bb

    aa

    bb

    aa

  • Page 6

    For Cometa 4 Zone (p/n): 8014For Cometa 6 Zone (p/n): 8016

    For Cometa 4 Zone (p/n): 8014For Cometa 6 Zone (p/n): 8016

    CometaCometa

    SETTING PROGRAMME A - WATERING DAYS- press button A once: the symbol appears and the cursor blinks on the first day of the week (number 1

    denotes Sunday)- press ENTER to activate the setting procedure- use to the arrows to select ON (watering active) or OFF (no watering)- press ENTER to confirm the setting- select another day using the arrows, and repeat the same steps for all the days of the week- press EXIT (buttons A and B) to quit the programming function

    User manualUser manual

    44 55 66

    dd

    11 22 33

    aa

    bb

    bbaa

    bb bb

    aa

    cc

    dd

    cc x 10

    aa

    bb

    aa

    bb

    aa onoff

  • Page 7

    For Cometa 4 Zone (p/n): 8014For Cometa 6 Zone (p/n): 8016

    For Cometa 4 Zone (p/n): 8014For Cometa 6 Zone (p/n): 8016

    CometaCometa

    MANUAL OPERATIONThis function can be used to open a single solenoid valve immediately and for a timed duration.- press the two arrow buttons simultaneously three times (MANUAL) until the display shows only the numbers of

    the valves, the symbol and the message ON or OFF; the cursor blinks on the first valve available- select the valve to be opened by moving the cursor with the arrows- press ENTER to confirm the selection, and proceed to set the watering duration- use the arrows to set the duration of watering in hours and minutes (up to 4h and 15’)- press ENTER to confirm the setting; watering will start immediately- press ENTER to stop watering before the set time has elapsed, if required- press EXIT (buttons A and B) to quit the manual function

    User manualUser manual

    44 55 66

    dd

    11 22 33

    cc

    dd

    bb

    aa

    bb

    aa

    bb

    aa

    cc

    dd

    cc

    bbaa bb

    bb

    aa

    Repeat the same sequence of steps for programme B

    x 3

    ... valve 3-4-5-6

    aa

  • Page 8

    For Cometa 4 Zone (p/n): 8014For Cometa 6 Zone (p/n): 8016

    For Cometa 4 Zone (p/n): 8014For Cometa 6 Zone (p/n): 8016

    CometaCometa

    STOP FUNCTIONThis function can be used to suspend watering for a duration ranging from a few minutes up to 15 days- press the middle button and the right arrow (STOP)- Press ENTER to activate the control function.- set the number of days for which watering is to be suspended, using the right arrow (10 days, for example). Press

    ENTER to confirm- press EXIT (buttons A and B) to quit the setting- press the middle button and the right arrow again (STOP) to reactivate watering.

    User manualUser manual

    44 55

    11 22 33

    dd

    bb

    aa

    bb

    aa

    max 4h 15’

    START!

    bbbb

    aa

    +-

    cc

    aa

    STOP!

    dd

    cc

    bb

    aa

  • Page 9

    For Cometa 4 Zone (p/n): 8014For Cometa 6 Zone (p/n): 8016

    For Cometa 4 Zone (p/n): 8014For Cometa 6 Zone (p/n): 8016

    CometaCometa

    SAFETY PROGRAMME The timer is provided with an internal memory containing a safety programme designed to activate each wate-ring line for 10 minutes a day, every day, when the time displayed in the clock field reaches 7:00. To activate this function, press buttons A and B simultaneously (EXIT) and hold them for at least 10 seconds. The display blinks, and pressing any button in this situation will restore the timer to the previous situation.

    User manualUser manual

    44 55 66

    11 22 33

    bbbb

    aaaa

    bb bb

    aa

    dd

    cc

    dd dd

    eecc

    bb

    aa

    10 sec.

    every day

    valve 1 10’

    valve 2 10’

    valve 3 10’

    valve 4 10’

    valve 5 10’

    valve 6 10’

    aa

    cc

    x 10

  • Page 10

    For Cometa 4 Zone (p/n): 8014For Cometa 6 Zone (p/n): 8016

    CometaCometa% FUNCTIONThe BUDGET function enables an easy and swift adjustment of the selected programme duration to changing climatic conditions; times can be varied without difficulty: either reduced to 0 (this is the quickest way to deacti-vate the set programme) or increased to 200%, without any need to change the watering duration selected in the programmes. 100% corresponds to the duration set when the timer is programmed. The adjustment is inde-pendent for each programme (A and B).- press the left arrow and the middle button (%): the symbols % and A will appear- press ENTER to activate the selection of a percentage for programme A- use the arrows to select the percentage (e.g. from 100% to 150%)- press ENTER to confirm the setting for programme A- press the left arrow and the middle button again (%): the symbols % and B appear- repeat steps 2) to 4) to select the percentage for programme B (example: from 100% to 75%)- press ENTER to confirm the setting for programme B- press EXIT (buttons A and B) to quit the % function

    For more information and further details, please consult the instruction manual supplied with the product.

    User manualUser manual

    11 22 33

    bb

    aa

    bb

    aa

    ff

    dd

    cc

    ee

    dd dd

    cccc

    0 ÷ 200 ff ff

    ee

    0 ÷ 200bb

    aa

    0 ÷ 200

    ee