Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
We have a number ofsolutions to reduce youroperational costs andyour greenhouse gasemissions
Our CHP systems offer a secure and energy efficient method ofgenerating electricity and heat from the same diesel or gas poweredgenerating set to achieve a significant reduction in energy cost
The electricity generated replaces or reduces the electricity boughtfrom the electrical supply utility while the heat generated replacesor reduces the heat normally provided by your heating boiler
COMBINED HEAT & POWER (CHP)
DIESEL CHP BIFUEL CHP GAS CHP GAS CHP
STANDARD DIESEL GENERATOR
STANDARD DIESEL GENERATORRUNNING ON STANDARD DIESELFUEL WITH A SET MOUNTEDRADIATOR AND ENGINE DRIVENCOOLING FAN FITTED WITH ANEXHAUST HEAT RECOVERY SYSTEM
BI-FUEL GENERATOR
STANDARD DIESEL GENERATORWITH A BIFUEL UP-GRADE WHICHALLOWS THE ENGINE TO RUN ON ADIESEL/GAS FUEL MIXTUREFITTED WITH AN EXHAUST HEATRECOVERY SYSTEM
STANDARD GAS GENERATOR
STANDARD GAS GENERATORRUNNING ON GAS FUEL WITH ASET MOUNTED RADIATOR ANDENGINE DRIVEN COOLING FANFITTED WITH AN EXHAUST HEATRECOVERY SYSTEM
SPECIAL GAS GENERATOR
SPECIAL GAS GENERATOR RUNNINGON GAS FUEL FITTED WITH ACOOLANT AND EXHAUST HEATRECOVERY SYSTEM AND DUMPRADIATOR FOR INDEPENDENTOPERATION
FUEL : 100% DIESEL
HEAT RECOVERY EXHAUST : YES
HEAT RECOVERY COOLANT : NO
HEAT RECOVERY : 50%
SERVICE INTERVAL HOURS : 500
CAPITAL COST : LOW
EXHAUST EMISSIONS : MEDIUM
RANGE : 30kVA - 2500kVA
FUEL : 30% DIESEL
: 70% GAS
HEAT RECOVERY EXHAUST : YES
HEAT RECOVERY COOLANT : NO
HEAT RECOVERY : 50%
SERVICE INTERVAL HOURS : 500
CAPITAL COST : LOW
EXHAUST EMISSIONS : MEDIUM
FUEL : 100% GAS
HEAT RECOVERY EXHAUST : YES
HEAT RECOVERY COOLANT : NO
HEAT RECOVERY : 50%
SERVICE INTERVAL HOURS : 15000
CAPITAL COST : MEDIUM
EXHAUST EMISSIONS : LOW
FUEL : 100% GAS
HEAT RECOVERY EXHAUST : YES
HEAT RECOVERY COOLANT : YES
HEAT RECOVERY : 90%
SERVICE INTERVAL HOURS : 15000
CAPITAL COST : HIGH
EXHAUST EMISSIONS : LOW
YOUR PARTNER IN CLEAN EFFICIENT HEAT & POWER
new
RANGE : 30kVA - 2500kVA RANGE : 240kVA - 1250kVA RANGE : 240kVA - 1250kVA
ECOPOWER
WHAT IS BI-FUEL DIESEL ENGINE BI-FUEL UP-GRADE
YOUR PARTNER IN CLEAN EFFICIENT HEAT & POWER
ECOPOWER
new
GAS TRAIN CONTROL PANEL
BI-FUEL is the name given toa mixture of GAS (70%) andDIESEL (30%) when used ina conventional diesel engine
The diesel engine remainsunchanged but gas isintroduced into the aircombustion system after theairfilter by means of a gasmixer
All the diesel engineparameters are kept withinnormal diesel limits whenoperated on BI-FUEL
LOWER ENERGY COSTSLOWER OPERATING COSTLOWER MAINTENANCE COSTLOWER EXHAUST EMISSIONS
BI-FUEL CHP
Our BI-FUEL CHP range (usingdiesel engines) is suppliedwith heat recovery on the engineexhaust and cooling systems
Because the engine is operatingon a 70% gas mixture therunning costs and maintenanceintervals approach that of agas engine
Our BI-FUEL CHP range retainsall the diesel engine advantages
LOW COSTSUPERIOR LOAD ACCEPTANCESIMPLE TECHNOLOGY
GAS MIXER
The BI-FUEL up-grade system consists of three major components:
GAS MIXER GAS TRAIN CONTROL PANEL
BI-FUEL COMBINED HEAT & POWER (CHP)
GAS
70%
DIESEL
30%
GENERATOR SET
ENGINE
ALTERNATOR
DIESEL FUEL30%
GAS FUEL70%
BENEFITS
RANGE
ADVANTAGES
TECHNICAL DATA
OUR ENTIRE STANDARD DIESELGENERATOR RANGE CAN BEUP-GRADED WITH A BIFUELSYSTEM
RANGE : 30KVA - 2500KVA
FUEL
HEAT RECOVERY SYSTEMSEXHAUST : YESCOOLANT : YES
Our BI-FUEL CHP systems offer a secure and energy efficient methodof generating electricity and heat from the same BI-FUEL powereddiesel generator set to achieve a significant reduction in energy cost
The electricity generated replaces or reduces the electricity boughtfrom the electrical supply utility while the heat generated replacesor reduces the heat normally provided by the heating boiler
Our CHP systems can reduceyour operational costs and yourgreenhouse gas emissions
Our CHP systems offer a secure and energy efficient means ofgenerating electricity and heat from the same Gas/Diesel/Bi-fuelpowered generator set to achieve a significant reduction in energycosts
The electricity generated replaces or reduces the electricity boughtfrom the electrical supply utility while the heat generated replacesor reduces the heat normally provided by the heating boiler
YOUR PARTNER IN CLEAN EFFICIENT HEAT & POWER
ECOPOWER
JACKET WATEROUT
JACKET WATERIN
EXHAUST GASOUT
GENERATOR SET
RADIATORFOR JACKETWATER
GAS/DIESEL/BI-FUELIN
ELECTRICITYOUT
RADIATOR AIR OFF VENTILION AIROFF
COMBUSTION& VENTILATIONAIR ON
RADIATOR AIR ON
23% WASTE HEAT 32% WASTE HEAT 40% USEFUL POWER5% WASTE HEAT
JACKET WATER EXHAUST ELECTRICITY RADIATED
RECOVERABLE HEAT
COMBINED HEAT & POWER (CHP)
Our CHP systems can reduceyour operational costs and yourgreenhouse gas emissions
Our CHP systems offer a secure and energy efficient means ofgenerating electricity and heat from the same Gas/Diesel/Bi-Fuelpowered generator set to achieve a significant reduction in energycosts
The electricity generated replaces or reduces the electricity boughtfrom the electrical supply utility while the heat generated replacesor reduces the heat normally provided by the heating boiler
YOUR PARTNER IN CLEAN EFFICIENT HEAT & POWER
ECOPOWER
EXHAUST GAS
HEATING SYSTEM RETURN HOT WATER
EXHAUST GASHEATEXCHANGER
EXHAUST GASOUT
PORTION OF RETURNHOT WATER PUMPEDTO CHP MODULE
HEATED WATER FROMTHE CHP MODULERE-ENTERS THE RETURNHOT WATER PIPE
GENERATOR SET(WITH INTEGRAL RADIATOR)
HEATED WATER RETURNED TO BOILER
GAS/DIESEL/BI-FUELIN
ELECTRICITYOUT
VENTILION AIROFF
RADIATORCOOLING,COMBUSTION& VENTILATIONAIR ON
COMBINED HEAT & POWER (CHP)
STANDARD : EXHAUST GAS HEAT EXCHANGER
OPTIONAL : JACKET WATER HEAT EXCHANGER
Our CHP systems can reduceyour operational costs and yourgreenhouse gas emissions
Our CHP systems offer a secure and energy efficient means ofgenerating electricity and heat from the same Gas/Diesel/Bi-fuelpowered generator set to achieve a significant reduction in energycosts
The electricity generated replaces or reduces the electricity boughtfrom the electrical supply utility while the heat generated replacesor reduces the heat normally provided by the heating boiler
YOUR PARTNER IN CLEAN EFFICIENT HEAT & POWER
ECOPOWER
EXHAUST GAS
HEATING SYSTEM RETURN HOT WATER
JACKET WATEROUT
JACKET WATERIN
JACKET WATERHEATEXCHANGER
EXHAUST GASHEATEXCHANGER
EXHAUST GASOUT
PORTION OF RETURNHOT WATER PUMPEDTO CHP MODULE
HEATED WATER FROMTHE CHP MODULERE-ENTERS THE RETURNHOT WATER PIPE
GENERATOR SET
DUMP RADIATORFOR JACKETWATER (OPTIONAL)
HEATED WATER RETURNED TO BOILER
GAS/DIESEL/BI-FUELIN
ELECTRICITYOUT
RADIATOR AIR OFFVENTILION AIROFF
COMBUSTION& VENTILATIONAIR ON
RADIATOR AIR ON
COMBINED HEAT & POWER (CHP)
STANDARD : EXHAUST GAS HEAT EXCHANGER
STANDARD : JACKET WATER HEAT EXCHANGER
Our CHP systems can reduceyour operational costs and yourgreenhouse gas emissions
Our CHP systems offer a secure and energy efficient means ofgenerating electricity and heat from the same Gas/Diesel/Bi-fuelpowered generator set to achieve a significant reduction in energycosts
The electricity generated replaces or reduces the electricity boughtfrom the electrical supply utility while the heat generated replacesor reduces the heat normally provided by the heating boiler
The heat generated by the CHP system can also provide chilledwater using an absorption chiller
YOUR PARTNER IN CLEAN EFFICIENT HEAT & POWER
ECOPOWER
EXHAUST GAS
FAN COIL UNITSPROVIDE COLD AIRTO THE SPACE
JACKET WATEROUT
JACKET WATERIN
JACKET WATERHEATEXCHANGER
EXHAUST GASHEATEXCHANGER
EXHAUST GASOUT
RETURN HOT WATERPUMPED TO CHPMODULE
GENERATOR SET
DUMP RADIATORFOR JACKETWATER (OPTIONAL)
COOLINGTOWER
GAS/DIESEL/BI-FUELIN
ELECTRICITYOUT
RADIATOR AIR OFFVENTILION AIROFF
COMBUSTION& VENTILATIONAIR ON
RADIATOR AIR ON
ABSORPTIONCHILLER
CHILLEDWATER
35°C
31°C
7°C
12°C
88°C
83°C
COMBINED HEAT & POWER (CHP)
Our CHP systems can reduceyour operational costs and yourgreenhouse gas emissions
Our CHP systems offer a secure and energy efficient means ofgenerating electricity and heat from the same Gas/Diesel/Bi-fuelpowered generator set to achieve a significant reduction in energycosts
The electricity generated replaces or reduces the electricity boughtfrom the electrical supply utility while the heat generated replacesor reduces the heat normally provided by the heating boiler
YOUR PARTNER IN CLEAN EFFICIENT HEAT & POWER
ECOPOWER
EXHAUST GAS
HEATING SYSTEM RETURN HOT WATER
JACKETWATER
JACKETWATER
JACKET WATERHEATEXCHANGER
EXHAUST GASHEATEXCHANGER
EXHAUSTGAS
PORTION OF RETURNHOT WATER PUMPEDTO CHP MODULE
HEATED WATERFROMTHE CHP MODULE
GENERATOR
DUMPRADIATOR
HEATED WATER RETURNED TO BOILER
GAS/DIESEL/BI-FUELIN
ELECTRICITYOUT
RADIATOR AIROFF
VENTILION AIROFF
COMBUSTION& VENTILATIONAIR ON
RADIATOR AIR ON
PARALLELINGSWITCHGEAR
CHPCIRCUITBREAKER
UTILITYCIRCUITBREAKER
UTILITYSUPPLYIN
CHPSUPPLY
IN
COMBINED HEAT & POWER (CHP)
The CHP electrical output is paralleled with theUtility Supply by means of two motorised circuitbreakers controlled by the CHP synchronisingcontrol panel
HE
AT
RE
CO
VE
RY
MO
DU
LE
WA
ST
EH
EA
TR
AD
IAT
OR
EX
HA
US
T P
IPE
JA
CK
ET
WA
TE
R P
IPE
CH
AR
GE
AIR
WA
TE
R P
IPE
OUR COMBINED HEAT & POWER (CHP)SYSTEMS OFFER A SECURE AND HIGHLYEFFICIENT METHOD OF GENERATINGELECTRICITY AND HEAT FROM THE SAMENATURAL GAS POWERED GENERATORSET TO ACHIEVE A SIGNIFICANTREDUCTION IN ENERGY COSTS
THE CHP GENERATES ELECTRICITYWHICH REPLACES OR REDUCES THEELECTRICITY NORMALLY BOUGHT FROMYOUR UTILITY SUPPLIER
THE CHP ALSO GENERATES HEAT WHICHREPLACES OR REDUCES THE HEATPROVIDED BY YOUR BOILER
THE GENERATED HEAT CAN ALSOPROVIDE CHILLED WATER USING ANABSOPTION CHILLER
CHP CAN PROVIDE REAL ECONOMICCOST BENEFITS AND AT THE SAME TIMEPRESERVE THE ENVIRONMENT
YOUR PARTNER IN CLEAN EFFICIENT HEAT & POWER
CHP
REDUCING ENERGY COSTS WHILEPRESERVING THE ENVIRONMENT
ECOPOWER