  • ElectromaxCombined electric boiler and domestic hot water store

  • 3

    ElectromaxElectromax provides efficient electric wet central heating

    and domestic hot water with the comfort and control of

    gas-powered systems, making it a perfect solution for over

    two million homes in Britain with no mains gas supply.

    Electromax includes a programmable room thermostat to take full

    advantage of off-peak electricity rates. It uses standard radiators

    and thermostatic radiator valves to reduce the cost of installation.

    To complement the range an underfloor heating version is also

    available. With long-term costs in mind, there is no need for the

    considerable expense and inconvenience of an annual gas safety

    certificate.

    Electromax comes with a 10 year cylinder guarantee and a two year

    guarantee for the boiler and all other controls with on-site service

    support.

    Specification Advice Hotline: 01603 420220 Email: [email protected]

  • 54

    Electromax installation

    Discharge pipe

    Auto air vent

    Pressurereliefvalve

    Temperatureand pressurerelief valve

    Pump

    Flow

    CylinderElectric boiler

    Cold watercombination

    valve (supplied)

    Coldmainsfeed

    To hotoutlets

    Return

    Automaticbypass valve

    Primaryexpansion

    vessel

    Potable waterexpansion vessel(supplied)

    Connectionto radiators

    or underfloorsystem

    7

    910

    6

    2

    4

    8

    5

    3

    17

    16

    4

    11

    15 1

    12

    13

    14

    Electromax

    Electromax has a host of features that benefit developers, builders, installers, landlords and end users to make it a desirable alternative where gas is not available or not the preferred option.

    Controllable,efficientwetcentralheating.

    Programmableroomthermostattoaccommodatea wide range of off-peak tariffs.

    Usesstandardradiatorsandthermostaticradiatorvalves.

    Designedforsealedsystems.

    Modelavailableforunderfloorheatingsystems.

    High-performancedomestichotwaterfromunvented direct hot water cylinder.

    CylindermanufacturedfromDuplexstainlesssteel.

    Noflueandnofueltanksallowflexibleinstallationlocation.

    Silentinoperation.

    Automaticpumpexercisefeatureforperiodswhen boiler is switched off.

    Frontcontrolpanelindicationtoshowboilerstatus.

    Provensolid-statetechnologyforlonglife.

    Softstartandzerovoltswitchingtoavoidpowersurges.

    Min/maxcontroladjuststhewatertemperatureoutput from the boiler.

    Minimalserviceandmaintenancecosts.

    Norequirementforannualgassafetycertificate.

    On-sitepartsandlabourguarantee. Cylinder10years. Boilerandothercontrolstwoyears.

    Key components 1 6or9kWAmptecboiler.

    2 Controls(PCBs).

    3 180litrecylinder(Duplexstainlesssteel).

    4 Elementsalloy825sheathed,incorporating thermalcontrolscombinedthermostatandthermalcut-out.Thermostatadjustable between 10C and 70C.

    5 InsulationCFC/HCFCFree(ODPzero)expanded polyurethane.

    6 Userinterfacecontrolsmountedinstylised facia panel.

    7 Expansion vessel.

    8 Pressurereliefvalve.

    9 Circulating pump.

    10 Autoairvent.

    11 Automaticbypassvalve.

    12 Programmableroomthermostat.

    13 Combinedpressurereducing/strainer/check/expansionvalve.

    14 Externally mounted potable water expansionvessel(18litre)supplied with wall mounting bracket.

    15 Tundish.

    16 Drainvalve.

    17 Primarysystemisolatingvalves.

    Central heating

    Electromax is suitable for use with wet radiator or underfloor sealed heating systems. Typical system layout given below is for illustrative purposes only.

    Domestic hot water

    Domestichotwater isprovidedbya180 litreunventeddirecthotwater cylinderwhichismanufacturedfromDuplexstainlesssteelformaximumstrengthandlonglife. Duplex stainless steel offers a superior resistance to corrosion especially inaggressive water areas, compared with copper, glass-lined steel and some lower grades of stainless steel.

    BecauseDuplexisalowcarbon,highchromiumcontentalloy,itresistsallformsofcorrosion including pitting, crevice corrosion, uniform corrosion and stress corrosion cracking, without the use of a sacrificial anode. In addition, the combination of tungsten inert gas and laser welding coupled with the special post-weld processes ensures the same level of corrosion resistance and mechanical strength as the parent metal. This ensures the longest possible working life for every cylinder.

    Thewaterisheatedbylong-lifeSuperloy825alloysheathedelementsincorporatedinto an easily removable heater plate, making replacement simple, if necessary.

    Electromax is supplied with a programmable room thermostat which controls the time periods that the boiler comes into operation and the room temperature. Offering up to three On and three Off periods per day and Weekday andWeekend programmes, the user is able to take advantage of the most appropriate off peak tariff best suited to their needs.

    The control panel on the unit includes a system pressure gauge, boiler indicator LEDs,boileron/offswitch,domestichotwateron/offandboostswitches.

    Running costs

    There are a number of off-peak electricity tariffs now available which provide a range of lower cost options for electricity used for heating and hot water. The two most common tariffs are Economy 7 and Economy 10. Types of meter and tariffs will vary by property and region. The following information is for general guidance only.

    Economy 7Two ratemeter installed in property. Units used at night (during off-peak time*)charged at lower rate than those used during the day.

    Economy 10

    Only onemeter installed in each property. All electricity used at off-peak timeschargedat the lower rate (suchaswashingmachines,dishwashersetc).Off-peaktimesgenerallysetformidnight5.00am;1.00pm4.00pm;and8.00pm10.00pm.

    *Night means the 7 hours that the local distribution company in your area chooses between 10pm and 10am. Day means at all other times. Not available in all areas, and details may vary by area.

    Specification Advice Hotline: 01603 420220 Email: [email protected]

  • 76

    DimensionsSpecificationCapacitiesBoiler1.3litres. Cylinder180litres.

    RatingsBoilers [email protected]([email protected]). [email protected]([email protected]). [email protected]([email protected]).

    ElementsBoilerLonglife,lowwattsdensity,copperelementsin a copper heat exchanger. CylinderLonglifeSuperloy825alloysheathedelements incorporated into an easily removable heater plate should replacement be necessary.

    Outer casingWhite stove-enamelled corrosion-resistant steel. ControlPanelfascialightgreyABS.

    Thermal insulationBoiler:Armaflexclosedcellinsulation.Dust,fibreandCFC/HCFCfree(ODPzero). CylinderCFC/HCFCFree(ODPzero)expandedpolyurethane.GWP2.72(GlobalWarmingPotential).

    ThermostatElectromaxboilerElectronicdualcontrol,useradjustablefrom65Cto80C. ElectromaxunderfloorboilerElectronicdualcontrol,useradjustablefrom30Cto60C. Electromaxcylinderelementthermostatadjustablefrom 10C to 70C.

    Water containerBoilerCopper. CylinderDuplex2304(Grade1.4362EN10088)stainless steel with external expansion vessel.

    Safety featuresBoiler2ampfusedpumpsupply,dualcontrolcircuits,dual switching of the elements, self-check circuitry and fault indication. Resettable thermal cut-out. CylinderManuallyresettablecut-outonheatingelementoperatesat85C(featureisanintegralpart ofthethermostat).

    Primary circuitPressurereliefvalvefactorysetto3bar.Cylinderfittedwith temperature and pressure relief valve, factory-set tooperateat10bar/90C.

    PumpGrundfosUPS15-50(withintegralautomaticairvent).

    Expansion vesselsPrimarysystemexpansionvessel(12litre/3bar)factoryfitted.Potablewaterexpansionvessel (18litre/3.5bar)suppliedloose.

    Bypass valveAutomaticbypassvalve(factory-fitted).

    Central heating controlsSuppliedwithprogrammableroomthermostatthreeOn/threeOffperiodsperday.Weekdayandweekend can be programmed separately. Battery operated.Polarity-freeconnectiontoboiler.

    ApprovalsNemkoapproved,CEmarked. ManufacturedintheUKinaBSENISO9001:2008, ISO14001:2004andBSOHSAS18001:2007registeredfactory.

    InstallationMustbeinstalledbyacompetentinstallerinaccordance with Local Regulations. EnglandandWalesBuildingRegulationsG3.ScotlandTechnicalStandardsP3. N.IrelandBuildingRegulationsP5.

    FixingFloor-mounting.Atemplateisprovidedtoassist in positioning.

    Plumbing connections22mmpipeworkonconnectionsonallmodels. Primaryfillingloopandprimarydrainpointvalve and hose connector supplied, bottom or side entry via panel knock outs.

    Primary system operating pressure3barmaximum.

    Operating temperaturePrimarysystemElectromaxfrom65Cto80C.

    PrimarysystemElectromaxUnderfloorfrom30C to 60C. Cylinder from 10C to 70C.

    Heating systemsSealedsystems.

    Pressure testingTestedto15bar.

    Cold water controlIntegrated cold water control set comprising pressure reducingvalveandstrainer(factorysetat3.5bar),expansionreliefvalve(factorysetat6bar)andcheckvalve.22mmcompressionfittings.

    Domestic hot water f ow [email protected]

    Min water requirementsRecommendedminimumsupplypressure 1.5bar/20l/minflowrate.Ifthereareanydoubtsabout water supply pressure or flow rates, please contactourSpecificationAdviceTeamtodiscuss.

    TundishFactory-fitted15mminletand22mmcompressionoutlet.

    ElectricalDesignedforconnectiontooff-peakelectricitysupply.Arangeofoff-peaktariffsareavailablenationallyitisrecommended that you contact your electricity supplier to determine the tariff best suited to your needs.

    Electric boiler must be permanently connected to electricity supply through a double pole linked i