OUTDOOR/INDOOR COMBINATION METER SOCKETS cos Murray combination meter sockets and load centers listed on this page are Underwriters' Laboratories Listed as service entrance equipment with bonded neutrals. The 100 ampere through 200 ampere JA devices have meter socket sections supplied with 4 meter jaws for use on 120/240V AC 10-3 wire services. These outdoor/indoor devices have a pullbox section that meets or exceeds EUSERC requirements, and load wiring may exit top or bottom. 400 ampere JB, JK and JL devices are rated 10-3 wire 120/240V AC. The units combine a 400 ampere load center with a self-contained meter mounting device for use with a Class 320 lever bypass, K-4 bolt-on meter or Class 320 non-lever bypass plug-in meter. These 400 ampere devices have mounting pads for line conductors with two studs per pad to accommodate NEMA two hole style compression connectors normally supplied by the utility for underground service. Alternate set screw lugs are available. See Accessories on page CO-6. Wire range is maximum allowable for wire- bending space provided. Lugs may accommodate larger wire. Refer to National Electrical Code or product wiring diagram for specific wire sizes. JA232CY JK330S In addition to local code and National Electrical Code requirements, the serving utility may have special requirements for metering devices. Confirm meter socket acceptance prior to order placement. Accessories — See page CO-6. Wiring Diagrams — See pages CO-7 through CO-9 Knockout Data — See pages CO-10 through CO-14. * O o ^ E 1 O "2. Z m m ZIO (/> O O ^ m </> Outdoor/Indoor, 1 -Phase, 3 Wire, 4 Jaw, 120/240V AC, 10,000 AIC, Load Top or Bottom, Meets EUSERC Requirements, Ring Type Branch Provisions Amps Main 1" Max. Surface (Max.) Breaker Spaces Circuits Service Cat # List Each Std. Pkg Approx. Wgt. Lb Semi-Flush s. Cat # List Each Std. Pkg.- Approx. Wgt. Lbs. -1 Hub Prov. Dimens Length ions Width Inches® Depth Wire Range Cu/AI MAIN BREAKER, FACTORY-INSTALLED 100 MEQ 12 24 OH/UG JA112CY 125 MEQ 12 24 OH/UG JA412CY 200 MEQ 20 40 UG MEQ 20 40 OH/UG JA220RK MP-A 32 40 UG JA232CY MEQ 40 40 OH/UG JA240CY® 399.00 726.00 1080.00 1070.00 1109.00 27.50 28.50 35.50 60.00 40.00 JA112CW JA412CW JA220CW JA220VH 399.00 726.00 1039.00 1080.00 29.50 30.50 42.00 40.00 HS HS HS HS HC HS 23 23 34 34 2854 34 14% 14% 14% 14% 20/8 22 5 5 5/i 5K 6% 5/2 #4-2/0 #4-2/0 #1-250kcmil #1-250 kcmil #4-250 kcmil #1-250 kcmil MAIN BREAKER, FIELD-INSTALLED 125 MP-T® 4 6 OH/UG JA004CY 200 MD-AorMP-T 4 6 OH/UG JA904CY 199.00 541.00 25.50 32.00 JA004CW JA904CW® 199.00 541.00 34.00 HS HS 23 34 14% 14% 5 5/2 #4-2/0 #1-250 kcmil R SOCKETS Underground Service® 1-Phase, 3 Wire, 120/240V AC, 400A Maximum, 22,000 AIC, Meets EUSERC Requirements Socket Type K-4 Bolt-on Class 320 Non-Lever Bypass Service Disconnec Amps 200A® 400A® 200A® 200A® 400A« Branch Provisions t 1" Spaces 30 24 30 30 24 Max. Circuits 40 40 40 40 40 Surface Cat#® JK330S JK424S JL230RS JL230S JL424S List Each 3221.00 4817.00 2119.00 3221.00 4817.00 Std. Pkg.—1 Approx. Wgt. Lbs. 130.00 150.00 130.00 130.00 150.00 Hub Prov. HV HV HV HV HV Dimensions Inches® Length 40/8 40 KB 40/s 40/8 40/8 Width 30/4 30/. 30/4 30/4 30H Depth 6/4 6/4 6/4 6/4 6/4 Wire® Range Cu/AI 1 set of 2 studs per leg 1 set of 2 studs per leg ©One or two MP-T breakers, not to exceed 125A total. ©Check utility approval. ©One MP2200KH installed. Provisions provided for one additional MD-A or MD-H (200 amps max.) style service disconnect to feed a remote load. Consult Circuit Breaker Coordination Chart on page LC-3 for downstream selections. ©Dimensions shown are representative of outside box length, width & depth (±W) and do not include allowances for mounting bumps, endwalls, covers, hubs or hardware protrusions. Consult factory for specific details if required. ©Semi-flush versions also suitable for overhead service. ® See accessories on page CO-6 for semi-flush flange kit. ©If required, order NEMA stud mechanical lugs from Accessories, page CO-6. ®For Semi-flush application, order JA240FK flushing kit. ®1 MP2200KH installed, Prov. for 1 MP-T or MP-HT (100 amps max.) to feed remote load. Consult circuit breaker coordination chart on page LC-3 for downstream selections. ® 1 JXD22B40D Factory installed. Discount Schedule "A'

COMBINATION METER SOCKETS …dlelectricsupply.com/files/JL424S.pdfCOMBINATION METER SOCKETS GENERAL DESCRIPTION < Combination meter socket for overhead service entrance and factory-installed

Embed Size (px)

Citation preview

Page 1: COMBINATION METER SOCKETS …dlelectricsupply.com/files/JL424S.pdfCOMBINATION METER SOCKETS GENERAL DESCRIPTION < Combination meter socket for overhead service entrance and factory-installed

OUTDOOR/INDOOR

COMBINATION METER SOCKETScos

Murray combination meter sockets and loadcenters listed on this page are Underwriters'Laboratories Listed as service entranceequipment with bonded neutrals. The 100ampere through 200 ampere JA devices havemeter socket sections supplied with 4 meterjaws for use on 120/240V AC 10-3 wireservices. These outdoor/indoor devices have apullbox section that meets or exceeds EUSERCrequirements, and load wiring may exit topor bottom.400 ampere JB, JK and JL devices are rated10-3 wire 120/240V AC. The units combine a400 ampere load center with a self-containedmeter mounting device for use with a Class 320lever bypass, K-4 bolt-on meter or Class 320non-lever bypass plug-in meter.These 400 ampere devices have mountingpads for line conductors with two studs perpad to accommodate NEMA two hole stylecompression connectors normally supplied bythe utility for underground service. Alternate setscrew lugs are available. See Accessories onpage CO-6.Wire range is maximum allowable for wire-bending space provided. Lugs mayaccommodate larger wire. Refer to NationalElectrical Code or product wiring diagram forspecific wire sizes.

JA232CY JK330S

In addition to local code and NationalElectrical Code requirements, the servingutility may have special requirements formetering devices. Confirm meter socketacceptance prior to order placement.

Accessories — See page CO-6.Wiring Diagrams — See pages CO-7 throughCO-9Knockout Data — See pages CO-10 throughCO-14.

*OoE

1O"2.ZmmZIO(/>OOm</>

Outdoor/Indoor, 1 -Phase, 3 Wire, 4 Jaw, 120/240V AC, 10,000 AIC,Load Top or Bottom, Meets EUSERC Requirements, Ring Type

Branch Provisions

Amps Main 1" Max. Surface(Max.) Breaker Spaces Circuits Service Cat # List Each

Std. PkgApprox.Wgt. Lb

Semi-Flushs. Cat # List Each

Std. Pkg.-Approx.Wgt. Lbs.

-1HubProv.

Dimens

Length

ions —

Width

Inches®

Depth

WireRangeCu/AI

MAIN BREAKER, FACTORY-INSTALLED100 MEQ 12 24 OH/UG JA112CY125 MEQ 12 24 OH/UG JA412CY200 MEQ 20 40 UG —

MEQ 20 40 OH/UG JA220RKMP-A 32 40 UG JA232CYMEQ 40 40 OH/UG JA240CY®

399.00726.00

—1080.001070.001109.00

27.5028.50—

35.5060.0040.00

JA112CWJA412CWJA220CWJA220VH——

399.00726.00

1039.001080.00——

29.5030.5042.0040.00——

HSHSHSHSHCHS

232334

34285434

14%14%14%14%20/822

555/i5K6%5/2

#4-2/0#4-2/0#1-250kcmil#1-250 kcmil#4-250 kcmil#1-250 kcmil

MAIN BREAKER, FIELD-INSTALLED125 MP-T® 4 6 OH/UG JA004CY200 MD-AorMP-T 4 6 OH/UG JA904CY

199.00541.00

25.5032.00

JA004CWJA904CW®

199.00541.00

—34.00

HSHS

2334

14%

14%55/2

#4-2/0#1-250 kcmil

R S

OC

KE

TS

Underground Service® 1-Phase, 3 Wire, 120/240V AC, 400A Maximum, 22,000AIC, Meets EUSERC Requirements

SocketTypeK-4Bolt-onClass 320Non-LeverBypass

ServiceDisconnecAmps200A®400A®200A®200A®400A«

Branch Provisions

t 1"Spaces3024

303024

Max.Circuits4040

404040

SurfaceCat#®JK330SJK424SJL230RSJL230SJL424S

List Each3221.004817.002119.003221.004817.00

Std. Pkg.— 1Approx.Wgt. Lbs.130.00150.00130.00130.00150.00

HubProv.HVHVHVHVHV

Dimensions — Inches®

Length40/840 KB

40/s40/840/8

Width30/430/.30/430/430H

Depth6/4

6/4

6/4

6/4

6/4

Wire®RangeCu/AI1 set of 2studs per leg1 set of 2studs per leg

©One or two MP-T breakers, not to exceed 125A total.©Check utility approval.©One MP2200KH installed. Provisions provided for

one additional MD-A or MD-H (200 amps max.) styleservice disconnect to feed a remote load. Consult CircuitBreaker Coordination Chart on page LC-3 fordownstream selections.

©Dimensions shown are representative of outside box length,width & depth (±W) and do not include allowances formounting bumps, endwalls, covers, hubs or hardwareprotrusions. Consult factory for specific details if required.

©Semi-flush versions also suitable for overhead service.® See accessories on page CO-6 for semi-flush flange kit.

©If required, order NEMA stud mechanical lugs fromAccessories, page CO-6.

®For Semi-flush application, order JA240FK flushing kit.®1 MP2200KH installed, Prov. for 1 MP-T or MP-HT

(100 amps max.) to feed remote load. Consult circuitbreaker coordination chart on page LC-3 fordownstream selections.

® 1 JXD22B40D Factory installed.

Discount Schedule "A'

Page 2: COMBINATION METER SOCKETS …dlelectricsupply.com/files/JL424S.pdfCOMBINATION METER SOCKETS GENERAL DESCRIPTION < Combination meter socket for overhead service entrance and factory-installed

COMBINATION METER SOCKETSGENERAL DESCRIPTION

<

Combination meter socket for overheadservice entrance and factory-installedmain circuit breaker with branchcircuit provisions.

Murray "combos" forconvenience...A full line of combination meter socketdevices in single, compact enclosures forfast, labor saving wiring and installation.Combination meter sockets consist of a metersocket section, sealable by the utility, andeither a main circuit breaker section withoutbranch circuit breaker provisions or a mainbreaker section with branch breaker provisions.The roain breaker section may be selected withthe main breaker factory-installed or withprovisions for field installation. These devicesare intended for use as service entranceequipment to combine the functions of:1. Meter Socket and Service Disconnect

or2. Meter Socket, Service Disconnect and

Load Center. This provides for all serviceconnections and power distribution in oneattractive and convenient location.

Design/Performance FeaturesMurray combination meter socketsload centers are listed by Underwriters'Laboratories, Inc. under file E10703 asservice entrance equipment with factorybonded neutrals.

1 Internal barriers prevent accessibility to lineterminals of meter socket after installationof meter.

1 Factory pre-wired or bussed from loadside of meter to line side of main circuitbreaker section.

Combination meter socket for overheadservice entrance with provisions for field-installed main circuit breaker — no branchcircuit provisions.

Combination meter socket for undergroundservice entrance with factory-installedmain circuit breaker and distribution section.

4

Combination meter socket for undergroundservice entrance with nailing strip forsemi-flush mounting. Includes factory-installed main circuit breaker with branchcircuit provisions.

• Enclosures are Outdoor, Type 3R, galvanizedsteel construction.

• Paint-Electrodeposition provides uniformcoverage for long-lasting protectionand appearance.

• 100-200A devices are of ring or ringless typeconstruction and feature one piece bus barconstruction, amply sized to run cool andprovide secure plug-in circuit breaker mounting.

• Knockouts ideally sized and located for easywire entry and exit.

1 For use with Murray main and branchcircuit breakers.

• Murray breakers through 125A areUnderwriters' Laboratories Listed for use with60°C or 75°C wire.

1 In addition to being ideally suited for residentialinstallations, these combination meter socketsmay be applied for rural service entrance, fortemporary construction site power distributionand for mobile homes. Consult your localdistributor for commercial or other installations.

W< i/ili.

CO 2

ooTO

16•2.

mm73coOO*mCO

Page 3: COMBINATION METER SOCKETS …dlelectricsupply.com/files/JL424S.pdfCOMBINATION METER SOCKETS GENERAL DESCRIPTION < Combination meter socket for overhead service entrance and factory-installed

COMBINATION METER SOCKETSTECHNICAL INFORMATION CG

Systems120/240V AC, 10-3 wire, 100 ampere thru400 ampere, 4 jaw120/208V AC, 3 wire, 100 ampere thru200 ampere, 5 jaw (field-installed)120/240V AC or 208Y/120V AC, 30-4 wire,100 ampere thru 400 ampere, 7 jaw

60°C/75°C Wire RatingMurray circuit breakers, Style MP-T (through125 amp) are listed by UL for use with 75°Cwire, at the 75°C rating. This listing allows useof smaller wire sizes in many applications.Consult table #310 and Article #336-26 of the1993 N.E.C. for application details and limitations.

When using aluminum wire,the following procedure isrecommended:1. Strip insulation completely from end of

wire to desired length. Avoid nicking orringing wire.

2. Wire brush exposed conductor strandscompletely.

3. Apply a coat of oxide inhibiting compound(such as Fargo Mfg. Co. "Fargolene" orequiv.) to exposed conductor strands.

4. Insert the conductor into connector.Make sure all strands of conductor arecontained and tighten connector screw tospecified torque.

5. Check all connections and retightenas necessary. Compact combination meter socket with

4-jaw self-contained meter socket and 40circuit load center. For overhead service.

JA220VH JA204TS

Combination meter socket for overhead orunderground service entrance with factory-installed main circuit breaker anddistribution section.

200 amp meter combo with main breakerand 4 1" positions for branch breakers andfeed-thru lugs. Pole mounting.

Complete SelectionNumber ofMeter Jaws 4, 5 or 7Voltage 240V AC MaximumAmpere 100 Amp^tOO Amp

MaximumMains Main Circuit Breaker

Installed or Provisions.Branch Provision to plug-inBreakers combinations of one, two

and three pole breakers.Application For indoor or outdoor

installations, surface orsemi-flush mounting, andcombining meter socketand load center.

P

Industry SpecificationsMurray combination meter sockets complywith the following industry standards:ANSI —C 12.7—1994American National Standard of WatthourMeter SocketsNEMA —Standard #PB1-1990UL Standard #50UL Standard #67UL Standard #414In addition to local code and NationalElectrical Code requirements, the servingutility may have special requirements formetering devices. Confirm meter socketacceptance prior to order placement.Refer to the "EM" Section for EUSERCapproved, commercial combination devices.

ooDO

\

Zmm30COOOm3

JC002CZ

Combination meter socket for overheador underground service entrance withprovisions for field-installed main circuitbreaker — no branch circuit provisions.