14
1 / 14 Doc No : CALCULATION Job No : FOR COLUMN BASE PLATE (H-SHAPE) Rev : Page : TITLE: Base Plate for H - Shape Steel Column (Hinged Type) 1. SKETCH OF COLUMN BASE PLATE Design loads = 382 kN = 100 kN Design data Column size H200X100X5.5X8 Depth ### mm Width ### mm Flange thicknes 5.5 mm Web thickness 8.0 mm Base plate B ### mm A ### mm Anchor bolt spa C 70.0 mm D 40.0 mm E mm F mm Thickness 20.0 mm Welding a 6.0 mm Rib plate Height H mm Thickness mm Anchor bolt Bolt size 20 mm No. of bolt 2 ea Materials Base plate SM490A Min. tensile st ### MPa Min. yielding s ### MPa ### MPa Anchor bolt Grade 4.6 <Design Result Summary> Shear strength ### 1. Base plate size ∴ O.K! Bedding Concrete 40.0 2. Base plate thickness ∴ O.K! 3. Welding in shear ∴ O.K! Welding Grade E43 4. Anchor bolt in shear ∴ O.K! Welding capacit ### Axial force (Fc) Shear force (Fv) Dc Bc Tc tc Depth (Dp) Width (Bp) Tp Tr Fu Fy Fy ps N/mm 2 fcu N/mm 2 Pw N/mm 2

Column Base Plate (Hinge Type)

Embed Size (px)

Citation preview

Page 1: Column Base Plate (Hinge Type)

1 / 14

Doc No :

CALCULATION Job No :

FOR COLUMN BASE PLATE (H-SHAPE) Rev :

Page :

TITLE: Base Plate for H - Shape Steel Column (Hinged Type)

1. SKETCH OF COLUMN BASE PLATE

Design loads

= 382 kN

= 100 kN

Design data

Column size H200X100X5.5X8

Depth 200.0 mm

Width 100.0 mm

Flange thickness 5.5 mm

Web thickness 8.0 mm

Base plate

B 250.0 mm

A 150.0 mm

Anchor bolt spacings C 70.0 mm

D 40.0 mm

E - mm

F - mm

Thickness 20.0 mm

Welding a 6.0 mm

Rib plate

Height H - mm

Thickness - mm

Anchor bolt

Bolt size 20 mm

No. of bolt 2 ea

Materials

Base plate SM490A

Min. tensile strength 490.0 MPa

Min. yielding strength 325.0 MPa

315.0 MPa

Anchor bolt Grade 4.6

<Design Result Summary> Shear strength 160.0

1. Base plate size O.K!∴ Bedding Concrete 40.0

2. Base plate thickness O.K!∴

3. Welding in shear O.K!∴ Welding Grade E43

4. Anchor bolt in shear O.K!∴ Welding capacity 215.0

Axial force (Fc)

Shear force (Fv)

Dc

Bc

Tc

tc

Depth (Dp)

Width (Bp)

Tp

Tr

Fu

Fy

Fy

ps N/mm2

fcu N/mm2

Pw N/mm2

Page 2: Column Base Plate (Hinge Type)

2 / 14

Doc No :

CALCULATION Job No :

FOR COLUMN BASE PLATE (H-SHAPE) Rev :

Page :

TITLE: Base Plate for H - Shape Steel Column (Hinged Type)

2. EFFECTIVE AREA METHOD - BASE PLATE SIZE

In this method it is assumed that the bearing pressure on the effective area is uniform and that the plate acts as a

simple cantilever around the perimeter of the section.

The projection width c is the minimum that is needed to keep the base pressure below the limiting bearing

the bedding material, whichever is less.

1) Basic requirement,

Area of base plate, = Bp x Dp

= 150 x 250 = 37500.00

Area required, =

= (382 x 10³ ) / (0.6 x 40 ) = 15916.67

Therefore, ≥ O.K!∴

☞ Column base plate has an appropriate size.

2-1) Assumption of overlapping

Equating the effective area to the required area gives,

where, Section perimeter = 784.00

Section area = 2612.00

Solving the above polynomial equation in terms of c,

4 784.00 c + -13304.67 = 0

=-784 ± √[ 784² - 4 x 4 x (-13304.67) ]

2a 2 x 4 = 15.71 mm

=200 - 2 x 5.5

= 94.50 > c2 2 O.K!∴

☞ Overlapping does not occur.

Checking whether base plate has sufficient dimensions to cover entire the effective area,

= 200 + 2 x 15.71 = 231.42 mm ≤ Dp = 250 mm O.K!∴

= 100 + 2 x 15.71 = 131.42 mm ≤ Bp = 150 mm O.K!∴

☞ Column base plate dimensions are sufficient.

strength which in this case is taken as 0.6 fcu, where fcu is the characteristic cube strength of the concrete base or

Ap ≥ Areq

Ap

mm2

Areq Fc / (0.6 fcu)

mm2

Ap Areq

Areq = 4c2 + (Section perimeter) c + (Section Area)

mm2

mm2

c2 +

∴ c =-b±√(b2-4ac)

Dc - 2Tc

Dc+2c

Bc+2c

Page 3: Column Base Plate (Hinge Type)

3 / 14

Doc No :

CALCULATION Job No :

FOR COLUMN BASE PLATE (H-SHAPE) Rev :

Page :

TITLE: Base Plate for H - Shape Steel Column (Hinged Type)

3. EFFECTIVE AREA METHOD - BASE PLATE THICKNESS

strength of the grout or the concrete base.

Basic requirement, thickness of base plate

½= 15.71 x

3 x 0.6 x 40 ½

315 = 7.51 mm

20.0 mm ≥ 7.51 mm O.K!∴

☞ Column base plate has an appropriate thickness.

4. BASE PLATE WELDS - SHEAR CAPACITY OF COLUMN-TO-BASE WELD

For bearing type bases the main function of the weld is to hold the column shaft securely in position on the

base plate.

Full profile welds will usually only be used for non-bearing bases or if additional strength is needed during

erection or as an anti-corrosion measure.

Basic requirement, = 215 x 378 x 4.2 / 1000 = 341.33 kN

where, design strength of weld 215.00

effective length of welds to column web (in direction of shear)

= 2 x ( 200 - 2 x 5.5 ) = 378.00 mm

a throat size = 0.7 x s = 4.20 mm

341.33 kN ≥ 100.00 kN O.K!∴

☞ Welding resists the shear force.

5. BOLT CONNECTION DESIGN - SHEAR CAPACITY

Holding down systems (anchor bolts) are intended that they must transmit shear from column to the foundation

in service. (Uplift is not considered herein)

100 / 2 = 50.00 kN

= 160 x ( 20² π / 4 ) / 1000 = 50.27 kN

50.27 kN ≥ 50.00 kN O.K!∴

☞ Anchor bolts resist the shear force.

The plate thickness must not be less than the flange thickness of the column, and fcu is taken as the weaker cube

Tp ≥ c3 x 0.6 fcu

Pyp

Tp =

Fv ≤ Pw = pw lwew a

pw N/mm2

lwew

Pw = Fv =

Shear force per bolts, Fs (kN) = (Shear force, Fv) / (No. of anchor bolt) =

Shear capacity per bolt, Ps (kN) = (Shear strength, ps) x (Area of bolt section, As)

Ps = Fs =

Page 4: Column Base Plate (Hinge Type)

4 / 14

07261D

REFERENCE

no uplift

refer to GIS G3106

t < 16

16 < t < 40

refer to BS 4190

refer to JES-43A1

Page 5: Column Base Plate (Hinge Type)

5 / 14

07261D

REFERENCE

Check 1

Page 6: Column Base Plate (Hinge Type)

6 / 14

07261D

REFERENCE

Check 2

*Design limitation for

Pyp = 270 N/mm

refer to BS 5950-1

Check 3

(full perimeter welds)

refer to BS 5950-1

Page 7: Column Base Plate (Hinge Type)

AVAILABLE SECTION LIST & PROPERTY for JAC

NO NameH Bf Tw Tf r A Ix

(mm) (mm) (mm) (mm) (mm)

1 H194X150X6X9 194 150 6 9 13 39.01 2630

2 H200X100X5.5X8 200 100 5.5 8 11 27.16 1810

3 H244X175X7X11 244 175 7 11 16 56.24 6040

4 H250X125X6X9 250 125 6 9 12 37.66 3960

5 H294X200X8X12 294 200 8 12 18 72.38 11100

6 H300X150X6.5X9 300 150 6.5 9 13 46.78 7210

7 H340X250X9X14 340 250 9 14 20 101.5 21200

8 H350X175X7X11 350 175 7 11 14 63.14 13500

9 H390X300X10X16 390 300 10 16 22 135 37900

10 H400X200X8X13 400 200 8 13 16 84.12 23500

11 H440X300X11X18 440 300 11 18 24 157.4 54700

12 H450X200X9X14 450 200 9 14 18 96.76 32900

13 H488X300X11X18 488 300 11 18 26 163.5 68900

14 H500X200X10X16 500 200 10 16 20 114.2 46800

15 H588X300X12X20 588 300 12 20 28 192.5 114000

16 H600X200X11X17 600 200 11 17 22 134.4 75600

17 H700X300X13X24 700 300 13 24 28 235.5 197000

18 H800X300X14X26 800 300 14 26 28 267.4 286000

19 H100X100X6X8 100 100 6 8 10 21.9 378

20 H125X125X6.5X9 125 125 6.5 9 10 30.31 839

21 H150X150X7X10 150 150 7 10 11 40.14 1620

22 H200X200X8X12 200 200 8 12 13 63.53 4720

23 H250X250X9X14 250 250 9 14 16 92.18 10700

24 H300X300X10X15 300 300 10 15 18 119.8 20200

25 H350X350X12X19 350 350 12 19 20 173.9 39800

26 H400X400X13X21 400 400 13 21 22 218.7 66600

Where,Zx, Zy Modulus of SectionSx, Sy Plastic Modulus of SectionSv Plastic Modulus of Web, means Plastic Modulus of Shear Area AvFor Calculation of Section Capacity, Refer BS5950-1:2000, Section 4

SM490A t < 16 t < 40 t > 40py 325 315 295

(cm2) (cm4)

Page 8: Column Base Plate (Hinge Type)

Iy Zx Zy Sx Sy Sv

507 271 67.6 309 104 46.5 2

134 181 26.7 209 41.9 46.6 1

984 495 112 558 173 86.2 1

294 317 47 366 73.1 80.7 1

1600 756 160 859 247 145.8 2

508 481 67.7 542 105 129.2 3

3650 1250 292 1410 447 219.0 2

984 771 112 868 174 188.3 3

7200 1940 480 2190 733 320.4 3

1740 1170 174 1330 268 279.8 3

8110 2490 540 2820 828 448.8 1

1870 1460 187 1680 291 400.7 3

8110 2820 540 3230 830 561.8 1

2140 1870 214 2180 335 547.6 3

9010 3890 601 4490 928 900.9 3

2270 2520 227 2980 361 881.0 3

10800 5640 721 6460 1120 1381.6 3

11700 7160 781 8240 1220 1958.3 3

134 75.6 26.7 87.6 41.2 10.6 1

293 134 46.9 154 71.9 18.6 1

563 216 75.1 246 115 29.6 1

1600 472 160 525 244 62.0 2

3650 860 292 960 444 110.9 2

6750 1350 450 1500 684 182.3 3

13600 2280 776 2550 1180 292.0 2

22400 3330 1120 3670 1700 416.5 3

BCICLASS(cm4) (cm3) (cm3) (cm3) (cm3) (cm3)

Page 9: Column Base Plate (Hinge Type)

Moment Capacity (KN.m)

Low Shear High Shear

=0.6*Av*py

227.0 100.4 85.3

214.5 67.9 52.8

333.1 181.4 153.3

292.5 119.0 92.7

458.6 279.2 231.8

380.3 156.3 128.3

596.7 458.3 387.1

477.8 250.6 209.8

760.5 630.5 543.8

624.0 380.3 319.6

943.8 916.5 746.9

789.7 474.5 387.7

1046.8 1049.8 840.5

975.0 607.8 474.1

1375.9 1264.3 1036.2

1287.0 819.0 608.8

1774.5 1833.0 1486.5

2184.0 2327.0 1844.2

117.0 28.5 25.0

158.4 50.1 44.0

204.8 80.0 70.3

312.0 170.6 150.5

438.7 312.0 276.0

585.0 438.8 399.3

819.0 828.8 711.3

1014.0 1082.3 961.5

ShearCapacity (KN)

※refer BS5950-1:2000, Section 4 ※assume Fv/Pv=1, ρ=[2(Fv/Pv)-1]2 = 1, which is about 20% consevative than Fv/Pv=0.6

Page 10: Column Base Plate (Hinge Type)

BASE PLATE SCHEDULE (H-PLATE) As per JAC0701-1-2A-010-024_0.dwg

No. Colume SizeAnchor Bolts Anchor Holes Base Plate

No. Size No. Size Thk. A B C D E F a H axial load(kN)

1 H194X150X6X9 2 20 2 26 20 200 250 100 50 6 382

2 H200X100X5.5X8 2 20 2 26 20 150 250 70 40 6 382

3 H244X175X7X11 4 20 4 26 22 220 300 140 140 40 80 6 200 10 495

4 H250X125X6X9 4 20 4 26 20 170 300 80 130 45 85 6 200 10 382

5 H294X200X8X12 4 24 4 30 22 250 350 150 150 50 100 6 200 10 495

6 H300X150X6.5X9 4 20 4 26 20 200 350 100 150 50 100 6 200 10 382

7 H340X250X9X14 4 24 4 30 22 300 390 170 170 65 110 8 200 10 635

8 H350X175X7X11 4 24 4 30 22 220 400 120 170 50 115 6 200 10 635

9 H390X300X10X16 4 30 4 36 25 350 440 210 210 70 115 8 250 10 780

10 H400X200X8X13 4 24 4 30 25 250 450 140 200 55 125 6 200 10 780

11 H440X300X11X18 4 30 4 36 30 350 490 240 240 55 125 8 250 10 1120

12 H450X200X9X14 4 24 4 30 25 250 500 140 230 55 135 8 200 10 920

13 H488X300X11X18 6 24 6 30 25 350 540 240 320 55 110 8 250 10 1120

14 H500X200X10X16 6 24 6 30 25 250 550 140 330 55 110 8 200 10 1120

15 H588X300X12X20 6 30 6 36 25 350 640 240 390 55 125 8 250 10 1120

16 H600X200X11X17 6 24 6 30 25 250 650 140 400 55 125 8 200 10 1120

17 H700X300X13X24 6 30 6 36 30 350 750 240 470 55 140 8 300 12 1535

18 H800X300X14X26 6 30 6 36 32 55 160 10 300 12

19 H100X100X6X8 2 20 2 26 20 150 150 70 40 6 382

20 H125X125X6.5X9 2 20 2 26 20 170 170 90 40 6 382

21 H150X150X7X10 2 20 2 26 20 200 200 120 40 6 382

22 H200X200X8X12 2 24 2 30 22 250 250 150 50 6 495

23 H250X250X9X14 4 24 4 30 22 300 300 120 120 90 90 8 200 10 495

24 H300X300X10X15 4 24 4 30 25 350 350 140 140 105 105 8 250 10 495

25 H350X350X12X19 4 30 4 36 25 400 400 160 160 120 120 8 300 10 780

26 H400X400X13X21 4 36 4 42 30 450 450 200 200 150 150 8 300 12 7800

Rib Plate Thk.

Page 11: Column Base Plate (Hinge Type)

Doc No :

CALCULATION Job No :

Rev :

Page :

BAB Gas Compression Project

Calculation

for End - Plate Connection (Reference Drawing NO. 11.99.76.2617.1 sht. 8/14)

FOR END-PLATE CONNECTION

Page 12: Column Base Plate (Hinge Type)

09065D

Page 13: Column Base Plate (Hinge Type)

Doc NO. :

CALCULATION Job No :

FOR MOMENT CONNECTION -1 Rev :

Page :

TABLE OF CONTENTS

1. Sketch and Input Data ------------------------------ 2

2. Bolt Design ------------------------------ 3

3. End - Plate Design ------------------------------ 3

4. Welding Design (E70XX electrode) ------------------------------ 4

5. Column Stiffner Check ------------------------------ 4

6. Column Stiffner Reinforcement Design ------------------------------ 5

7. Diagonal Stiffener Check ------------------------------ 5

Page 14: Column Base Plate (Hinge Type)

P90115

A