/Spectrodensitometer
DensityIllumination
Color
Streamlines color adjustment in printing, even on substrates with fluorescent whitening agents
3-in-1 next-generation measurement toolColor
Density
Illumination
Spectrodensitometer
/14
Color
IlluminationIllumination environment light can be measured. (FD-7 only)
• Theilluminanceandcolortemperatureinacolorviewingcabinetortheactualambientlightunderwhichprintedmaterialswillbeevaluatedcanbemeasured.
The world’s first measuring instrument that corresponds to Measurement Condition M1 of ISO 13655• KonicaMinolta’soriginalVFS(VirtualFluorescenceStandard) technologyenablesL*a*b*measurements
correspondingtoISO13655MeasurementConditionM1.• TheFD-7andFD-5can takemeasurementscorresponding toall fourof theISO13655Measurement
Conditions.Measurementscorresponding toM1areenabledbyKonicaMinolta’soriginalVFS(VirtualFluorescenceStandard) technology,andmeasurementscorrespondingtoM0(CIEIlluminantA)andM2(illuminationwithUV-cut filter)canalsobetaken.Inaddition,byattachingtheincludedpolarizationfilter,measurementscorrespondingtoM3(M2+polarizationfilter)canbetaken.
Target Match function*1*2
• Displaysthecolordifferencefromthetargetcolorandtheprocesscolororspotcolordensityadjustmentneededtobringthemeasuredcolorclosertothetargetcolor.ByusingtheTargetMatchfunction,inkcoloradjustmentcanbeperformedwithoutacomputerorspecialsoftware.· Idealforspotcolorsorprocesscolors.· Displayscolordifferenceanddensity.· Displaysestimateddensity
adjustmentneededtobringthemeasuredcolorclosertothetargetcolorandthepredictedcolordifferenceafteradjustment.
Functions corresponding to various printing standards• Pass/failjudgmentagainstISO,JapanColor,GRACoL®/SWOP®,
PSO,oruser-definedcustomtargetscanbeperformed.TheFD-7andFD-5areidealforon-siteprintingqualitycontrol.· ISO12647check*1*2
Colordifference,TVI,andmid-tonespreadcanbeevaluated.· Graybalance
GraybalancecanbeevaluatedusingtheG7®evaluationmethod.
Scan measurements can be performed. (FD-7 only)
• ManualscanmeasurementscanbeperformedwhentheinstrumentisconnectedtoaPC.
• WithoptionalsoftwarebasICColorcatchall,thecolorimetricvalues,densityvalues,andspectralreflectancevaluesofvarioustestcharts(MediaWedgeECI2002,IT8.7/3,etc.)canbemeasuredinasingleoperation.
Spectral output (FD-7 only)
• WhentheFD-7isconnectedtoacomputer,thespectralreflectancedata(380to730nm)ofsamplesundervariousilluminantsandthespectralirradiancedata(360to730nm)oftheenvironmentallightingcanbemeasuredandoutputtoacomputer.ThismakestheFD-7idealforresearchanddevelopmentapplications.
Measured environmental light can be set as illumination light source (user illuminant)• Inthepast,whenmeasuringprintedmaterialscontainingfluorescentwhiteningagents
(FWA),largedifferencesbetweenmeasuredvaluesandvisualevaluationsometimesoccurred.ButwiththeFD-7,colorimetricvaluescanbecalculatedunderthemeasuredenvironmentallightsource,providingresultswhichmorecloselycorrespondtoon-sitevisualevaluation.ThisensurescustomersreceivethecolorstheywantandeliminatestimeandlaborlostresolvingcustomercomplaintsduetotheeffectsofFWAormetamerism.
A high-accuracy, compact, lightweight, handheld, next- generation spectrodensitometer that measures color, density, and illumination* for applica tions from R&D to quality control.
*1 Targetcolors(colorsets)mustbesetusingtheincludedFDDataManagementSoftwareFD-S1w.*2 Backingconversion functionconverts the targetvalues toenableevaluationevenwhenbacking
conditionsforsamplesdonotmatchthoseofthetargets.
Printing quality control functions including trapping, dot gain, etc.• Anewindustry-standardtoolforcommercialprintingandpackaging
printingtoimproveproductivityandqualityatlowcost.
• CMYK density • Dot area • Dot gain • Trapping • Simple density difference• PS plate dot area • PS plate dot gain • Spot color density
Data Mana gement Software FD-S1w
(included as stand ard accessory)Features:•TransferofmeasurementdatatoExcel®sheet.•Reading/registeringofuserilluminantdatato/frominstrument andstorageasPCfile
•Colorsetmanagementfunctions(forinstrumentISO12647CheckandTargetMatchfunctions)*1*2
TARGETMATCH
Measure sample
PaperM1 2° D50
TargetSample
⊿D(400)⊿E*94
+0.30 D
2.54 @> > 0.48 @
0.86 D1.16 D
Measure color difference.Result: Adjusting the density of spot color with 400 nm peak absorbance from 0.86 to 1.16 is predicted to result in a color difference of 0.48.
Improvements in quality control functions to meet more advanced
needs at printing locations.
*FD-7 only
00.20.40.60.811.21.41.61.82
300 320 340 360 380 400 420 440 460 480 500
Relative intensity (a.u.)
Wavelength (nm)
Measured light source intensity distribution
AD50D65A(Uvcut)
0
20
40
60
80
100
120
140
380 430 480 530 580 630 680 730
Spectral reflectance(%)
Wavelength (nm)
AD50D65A(UVcut)
By measuring the environm ental light source with an FD-7 master body and then transferring the user illuminant data to multiple FD-5 or FD-7 working bodies, color cont rol using the same illumination light source at multiple locations can be achieved. In addition, the automatic wavelength compensation function min imizes inter-instrument errors when using multiple instruments.
FD-7 (Master body)
FD-5 (Working body)
FD-5(Working body)
ISO CHECK
Red : Pass
M1 2° D50Yellow40%
BlueGreenRed
CS01:PT1-AM-BB16/21
-0.320.08-0.220.40
⊿L* ⊿a*⊿b*⊿E*ab
System RequirementsOS WindowsXP,Windows
VistaorWindows7;32-bitor64-bitversions
Excel Excel2003(WindowsXP),Excel2007(WidowsVista),orExcel2010(32-bitversion;Windows7)
ThehaedwareorthecomputersystemtobeusedmustmeetorexceedtherecommendedsystemrequirementsforthecompatibleOSandExcelversionbeingused.
Compatible Instruments SpectrodensitometerFD-7,FD-5Display language English,Japanese,
Chinese(Simplified) (Selectoneduringinstallation.)
Density
• Enablescolormeasurement,ICCprofilecreation,andqualitycontrol(pass/failevaluationandcertification).
• Incorporatesavarietyofprofileevaluation functions,suchas tonecurves for2D/3DcolorgamutsandΔEcomparisonanddisplay,andsupports functions that improveprofilequality(measurementdatasmoothing,duplicatepatchcorrection,defect[measuredvalue]correction).
• Enablesprofilecreationwithmulti-channeldata(sevencolorsatmost)havingmorecolors thanCMYKfullcoloraswellasnormalmeasurementandnormalprofilecreation.
• Supportsdevice linkprofilecreation,editing,andevaluation.CanautomaticallycreateandoutputPDFreports.
• SupportsA3+andA4+sizes.Measurementscanbeefficientlydonewithoutcutting,foldingandswitchinginandoutimportantcolorcharts
• DefinitionsfilescanbeeasilycreatedforchartsusingtheClrChrtapplicationthatcomesstandardwiththeproduct.
• DatacanbesavedinANSI8.7orCGATS.5formatandexportedtoprofileeditingsoftware.Colorscanbereproducedclosertowhatisperceivedwiththehumaneye,byusingM1lightsourcesoruser-definedlightsources.
• TheESseriesuseselectrostaticattractiontoimmobilizechartsduringmeasurement.
Optional accessories
Measurementdata Chartdesignscreen
ClrChrtsoftware(Included)
XY Automatic Color-Measurement Stage ColorScout series *5
TheColorScoutseriesenablesaccurate,high-efficiencymeasurementsofcolorchartswiththeSpectrodensitometerFD-7andFD-5.Itenablesautomaticpositioningandmeasurementoftheinstrument,providinghigherrepeatabilityandreducinglaborcomparedtomanualmeasurements.
Color Management Software basICColor series *5
ThesoftwarecontainsinterfacesforallmodelsoftheFDseriesandenablesuserstohandleeverythingfrommeasuringcolorstocreating,analyzingandmanagingthequality(pass/failjudgment)ofICCprofiles.
For major efficiency increases in daily color control work.
Capable of both spot and scan measurements!
XY automatic color-measurement stage Backingsheetavailableaseitherwhitesurfaceorblacksurface.
WiththenewE*94andE00colordifferenceequationsaswellasauserindexthatallowsuserstofreelysettheirownevaluationequations,SpectraMagic®NXcanmeetawidevarietyofuserneeds.Measurementdatacanbedisplayedinlistformorinobjectssuchasspectralgraphs,color-differencegraphs,etc.thattheusercanfreelylayout,andthoseobjectscanbecopiedandpastedasisintoothersoftwaresuchasExcel®foreasydatacontrol.Inaddition,printingscreenscanalsobedesignedusingthesameobjectstocreateuser-definedformatsforeasy-to-readreports.
Color Data Software SpectraMagic® NX *5
Idealforcolor-differencecontrolofspotcolorsrelativetotargetcolors.
Achieves overall ease of use with free selection of evaluation equations and report formatting.
Listdisplay
Color-differencegraphobject PastedintoExcel®
Printingscreen
SpecificationColorScout
A3+ColorScout
A3+ESColorScout
A4+ESElectrostaticattraction -Measureablesizes 320x460mm 320x460mm 320x230mmSamplethickness Max1.5mm Max1.0mm Max1.0mm
ColorChart minimum computing requirements
OS;CPU Windows® XP(32-bit), Windows® 7(32-bit,64-bit);300MHzorfaster
Harddisk;Memory
30MBormoreavailablediskspace;64MBormore
World's lightest*4
• Themainbodyweighsonlyabout350g,andevenwith the targetmask attached it's only about 430g, lighter than anypreviousspectrodensitometer.
• Thisreducestheloadontheuser'sarmduringwork,improvingefficiencywhentakingmeasurementsoveralongtime.
*4Display-equippedspectrodensitometer.AsofDecember1,2012
Industry's first automatic wavelength compensation function• Wavelengthcompensationisperformedduringwhitecalibration*3without
requiringadditionalwork.• Untilnow,wavelengthcompensationcouldonlybecarriedoutasonepart
ofmanufacturerservicing.Thistaskisnowperformedwheneverwhitecalibration*3isdone,helpingtomaintainthehighreliabilityofmeasurementvaluesuntilthenextperiodicservicing.
*3Exceptwhenpolarizationfilterisattached.
Worry-free after-sales service• Worldwideservicecentersproviderapidsupportwhenneeded.• Acomprehensiveservicenetworkisinplacetoensurethatyourinstrumentisalwaysintopshape.
Wavelength
Wavelength-direction shift
Spe
ctra
l ref
lect
ance
Minimum computing requirements
OS Windows®7/8/8.1/10OSX®10.9*-10.10
CPU Intel®Pentium4-Processor
Memory 4GBormore
Harddisk 2GBormoreavailablediskspace
*basICColorPrintrequiresOSX®10.9.5orabove.
*5 Measurements with polarization filter attached cannot be performed.
Minimum Computing Requirements
OS
Windows®Vistabusiness32-bit,64-bit;Windows®7Professional32-bit,64-bit;Windows®8.1Pro32-bit,64-bit;Windows®10Pro32-bit,64-bit(English,Japanese,German,French,Spanish,Italian,TraditionalChinese,SimplifiedChinese,Portuguese,andHangulversions)•Thehardwareofthecomputersystemtobeusedmustmeetorexceedthegreaterofthe
recommendedsystemrequirementsforthecompatibleOSbeingusedorthefollowingspecifications.CPU Pentium®lll600MHzorhigher(recommended)Memory 128MB(256MBrecommended)Harddisk 450MBofavailablediskspace(Atleast400MBofavailablespaceisrequiredinthesystemdrive.)
Dimensions (Units: mm)
Withremovabletargetmaskattached
171.5165
84.2
90
70
25 φ6.2
System Diagram
SpectrodensitometerFD-7/FD-5
Protection GlassFD-A04
USB Cable (Shape may vary by region.)IF-A17 (Europe)IF-A23 (worldwide except Europe)
White Calibration Plate
FD-A06
Target MaskFD-A01
RulerFD-A02
Illuminance AdapterFD-A03
Soft CaseFD-A05
AC Adapter(Shape may vary by region.)
Optionalaccessories
FD-5, FD-7Standard accessories
Standard accessoriesonly of FD-7
Color ManagementSoftwarebasICColor catch all
XY Automatic Color- Measurement StageColorScoutA3+
Data Management SoftwareFD-S1w
CM-S100wSpectra Magic® NXProfessional EditionBasic Edition
Polarization FilterFD-A08
PC(commercially available)
Certificate No : JQA-E-80027Registration Date : March 12, 1997
Certificate No : LRQ 0960094/ARegistration Date : March 3, 1995
For correct use and for your safety, be sure to read the instruction
manual before using the instrument.
• Always connect the instrument to the specified power supply
voltage. Improper connection may cause a fire or electric shock.
SAFETY PRECAUTIONS
9242-4897-10BGMPKPrintedinJapan©2010-2016KONICAMINOLTA,INC.
•Displaysshownareforillustrationpurposeonly.•Thespecificationsandappearanceshownhereinaresubjecttochangewithoutnotice.•KONICAMINOLTA, theKonicaMinolta logoandsymbolmark, "GivingShape to Ideas"andSpectraMagic™are registeredtrademarksortrademarksofKONICAMINOLTA,INC.
•ThebasICColorlogoisaregisteredtrademarkofbasICColorGmbH.•Othercompanynamesandproductnamesusedhereinaretrademarksorregisteredtrademarksoftheirrespectivecompanies.
Function FD-7 FD-5Densitymeasurementfunctions
Density,densitydifference ● ●Dotarea ● ●Dotgain ● ●Trapping ● ●
PSplatedotarea ● ●PSplatedotgain ● ●
Spotcolordensity ● ●Graybalance ● ●
Midtonespread ● ●ISO12647check ● ●
Targetmatch ● ●Colorimetricmeasurementfunctions
L*a*b* ● ●L*C*h ● ●
HunterLab ● ●Yxy ● ●
XYZ ● ●E*ab(CIE1976) ● ●E*94(CIE1994) ● ●E00(CIE2000) ● ●
E(Hunter) ● ●CMC(l:c) ● ●
Illuminancemeasurementfunctions
Illuminance ●Correlatedcolortemperature ●
Paperindex
WI/Tint(ASTME313-96) ● ●ISOBrightness(ISO2470-1) ● ●D65Brightness(ISO2470-2) ● ●
Fluorescenceindex ● ●Spectralreflectance
Spectraldataoutput ●Memory
Targetdensity 30 30
Targetcolor 30 30
Colorsetsof15colorseach*1 50 50
Otherfunctions
Manualscan*2 ●Automaticfunction
(density,dotarea,color)● ●
PASS/FAILjudgment ● ●Software
basICColorseries ● ●FD-S1w ● ●
SpectraMagicNX ● ●ClrChrt
(IncludedwithColorScoutseries)● ●
Main specificationsIllumination/viewingsystem
45°a:0°(annularillumination)*3ConformstoCIENo.15,ISO7724/1,DIN5033Teil7,ASTME1164,andJISZ8722Conditionaforreflectancemeasurements.
Spectralseparationdevice Concavegrating
Wavelengthrange Spectralreflectance:380to730nm;Spectralirradiance(FD-7only):360to730nmWavelengthpitch 10nmHalfbandwidth Approx.10nmMeasurementarea Ø3.5mmLightsource LEDMeasurementrange Density:0.0Dto2.5D;Reflectance:0to150%
Short-termrepeatability
Density: σ0.01D Withoutpolarizationfilter:0.0D~2.5D,Yellow0.0D~2.0D Withpolarizationfilter: 0.0D~2.5D,Yellow0.0D~1.8D (Whenmeasurementstaken30timesat10-secondintervalsafter
whitecalibrationhasbeenperformed)Colorimetric: Withinσ E000.05(Withoutpolarizationfilter) (Whenwhiteplateismeasured30timesat10-secondintervals
afterwhitecalibrationhasbeenperformed)
Inter-instrumentagreement
Within E000.3(Averageof12BCRASeriesIIcolortilescomparedtovaluesmeasuredwithamasterbodyunderKonicaMinoltastandardconditions;withoutpolarizationfilter)
Measurementtime Approx.1.4s(single-pointreflectancemeasurementwithoutpolarizationfilter)
Measurementconditions
CorrespondingtoISO13655MeasurementConditionsM0(CIEIlluminantA),M1(CIEIlluminantD50),M2(illuminationwithUV-cutfilter),andM3(M2+polarizationfilter);User-definedilluminant
Illuminant A,C,D50,D65,ID50,ID65,F2,F6,F7,F8,F9,F10,F11,F12,User-definedilluminant
Observer 2°or10°StandardObserverDensity ISOStatusT,ISOStatusE,ISOStatusA,ISOStatusI;DIN16536Displaylanguage English,French,German,Spanish,Japanese,Chinese(Simplified)Interface USB2.0
Outputdata*2 Displayedvalues;Spectralreflectancedata(FD-7only);Spectralirradiancedata(FD-7only)
Power Rechargeableinternallithium-ionbattery(Numberofmeasurementspercharge:Approx.2,000whennewwithoutpolarizationfilter);ACadapter;USBbuspower
Size(W×D×H) 70×165×83mm(Bodyonly);90×172×84mm(Withtargetmaskattached)Weight Approx.350g(Bodyonly);Approx.430g(Withtargetmaskattached)Operationtemperature/humidityrange 10to35°C,30to85%relativehumiditywithnocondensation
Storagetemperature/humidityrange 0to45°C,0to85%relativehumiditywithnocondensation
StandardaccessoriesWhiteCalibrationPlate,TargetMask,ProtectionGlass,ACAdapter,USBCable,SoftCase,PolarizationFilter,DataManagementSoftwareFD-S1w,IlluminanceAdapter(FD-7only),Ruler(FD-7only)
OptionalaccessoriesColorManagementSoftwarebasICColorseries,XYAutomaticColorMeasurementStageColorScoutseries,ColorManagementSoftwareSpectraMagicNX
*1UsedforISO12647Check/Targetmatch;MustbesetusingincludedFD-S1wsoftware.*2AvailablewhenusingPCsoftware.*3Illuminationforwavelengthsunder400nmisunidirectional.