8
Mastering light together H5 500 Low glare, dimmable, fire-rated, IP65, LED downlight range The Professional’s Guide

Collingwood Lighting H5 500 Range Guide (UK)

Embed Size (px)

DESCRIPTION

H5 500 - Low glare, dimmable, fire-rated IP65, LED downlight range

Citation preview

Page 1: Collingwood Lighting H5 500 Range Guide (UK)

Mastering light together

H5 500Low glare, dimmable, fire-rated, IP65, LED downlight range

The Professional’s Guide

Page 2: Collingwood Lighting H5 500 Range Guide (UK)
Page 3: Collingwood Lighting H5 500 Range Guide (UK)
Page 4: Collingwood Lighting H5 500 Range Guide (UK)

1. A 64mm hole needs to be cut into the ceiling. Taking care to avoid joists, cables and pipes. The LED housing is then fitted into the hole and secured to the ceiling.

2. The ceiling can now be plastered up to the lip of the LED housing.

3. The ceiling can now be decorated, blending the housing seamlessly into the ceiling. Finally, the LED unit is fitted and clipped into place.

Scan to watch the H5 500 Trimless installation video.

H5 500 Trimless AccessoriesEmergency pack and our recommended mains dimmer also available.

H5 500 Trimless Installation Guide

H5 500 Range

Use the H5 500:

Trimless - To see the light and not the light source.Symmetric - To enjoy the light without the glare.Asymmetric - To enhance a feature.

Page 5: Collingwood Lighting H5 500 Range Guide (UK)

Inside the H5 500 Trimless

An adjustable mains dimmable driver makes positioning during installation much easier, even in fire rated ceilings.

We were the first to the UK electrical wholesale market with a heat sink positioned outside of

the fire can, giving improved light output and life. Our fire can meets

30, 60 or 90 minute burn times.

LEDs recessed to create a low glare, more natural look and feel to the light output.

Designed by Collingwood engineers to be 92% efficient, the lens is available in 38° beam angle and features a micro lens surface to reduce glare.

Produces 80% more light than a traditional 50W GU10

halogen fitting and up to 40% brighter on average than a

GU10 LED replacement fitting.

Meets building regulations part B (fire protection), C (moisture protection), E (acoustic protection), P (electrical

safety) and L (conservation of energy).

Plastered in low glare, discreet fitting. 2 part installation for

first and second fix

Patent Pending: 1102073.2

Page 6: Collingwood Lighting H5 500 Range Guide (UK)

An adjustable mains dimmable driver makes positioning during installation much easier, even in fire rated ceilings.

Choose from three bezel options available

in White, Chrome & Brushed Steel.

We were the first to the UK electrical wholesale market with a heat sink positioned outside of

the fire can, giving improved light output and life. Our fire can meets

30, 60 or 90 minute burn times.

LEDs recessed to create a low glare, more natural look and feel to the light output.

Designed by Collingwood engineers to be 92% efficient, the lens is available in 38° beam angle and features a micro lens surface to reduce glare.

Produces 80% more light than a traditional 50W GU10

halogen fitting and up to 40% brighter on average than a

GU10 LED replacement fitting.

Two spring positions for installation in varying ceiling thickness.

Inside the H5 500 Symmetric & Asymmetric

Symmetric version shown

Meets building regulations part B (fire protection), C (moisture protection), E (acoustic protection), P (electrical

safety) and L (conservation of energy).

Applicable to both Symmetric and Asymmetric versions.

Page 7: Collingwood Lighting H5 500 Range Guide (UK)

Patent No: GB2462155Patent Pending: 1102073.2

H5 500 Sym & Asym AccessoriesChoose from three converter plates, available in White, Chrome & Brushed Steel to enable retrofit into large ceiling holes up to 150mm. Emergency pack and our recommended mains dimmer also available.

H5 500 Sym & Asym OptionsThe H5 500 is available in both symmetric and asymmetric versions. The symmetric version is ideal for general room lighting where an even spread of light is required. The asymmetric version is perfect for lighting a specific area such as a picture or feature.

Page 8: Collingwood Lighting H5 500 Range Guide (UK)

V1

GENERAL

Building regulations Part B (fire protection), C (moisture protection), E (acoustic protection), P (electrical safety) and L (conservation of energy)

Cut-out (mm) 95-115 (H5 500 Trimless: 64mm)

IP rating 65

Rotation angle (°) N/A

Tilt angle (°) N/A

WARRANTY

1 year (7 year extended warranty available)

H5 500 SYMMETRIC PHOTOMETRICS @ 25°C

Colour Finish Product code Beam angle Wattage Life of LED CRI lm lm/W lx (1m)

NW / 4000K B/Steel DL284BSNWDIM

40° 8.5WL70, B10

70,000hrs

>70Ra 550 65 1500Chrome DL284CRNWDIM

White DL284WHNWDIM

WW / 3000K B/Steel DL284BSWWDIM

>80Ra 470 55 1200Chrome DL284CRWWDIM

White DL284WHWWDIM

H5 500 ASYMMETRIC PHOTOMETRICS @ 25°C

Colour Finish Product code Beam angle Wattage Life of LED CRI lm lm/W lx (1m)

NW / 4000K B/Steel DL283BSNWDIM

40° 8.5WL70, B10

70,000hrs

>70Ra 550 65 1261Chrome DL283CRNWDIM

White DL283WHNWDIM

WW / 3000K B/Steel DL283BSWWDIM

>80Ra 470 55 1149Chrome DL283CRWWDIM

White DL283WHWWDIM

H5 500 TRIMLESS PHOTOMETRICS @ 25°C

Colour Finish Product code Beam angle Wattage Life of LED CRI lm lm/W lx (1m)

NW / 4000K White DL282WHNWDIM38° 8.5W

L70, B10

70,000hrs>70Ra 550 65 1772

WW / 3000K White DL282WHWWDIM >80Ra 470 55 1595

Scan to view the full Halers range from Collingwood Lighting.

Collingwood Lighting

T 01604 495151 F 01604 495095E [email protected] W collingwoodlighting.com