Coleman FPSE Manual

Embed Size (px)

Citation preview

  • 8/4/2019 Coleman FPSE Manual

    1/6

  • 8/4/2019 Coleman FPSE Manual

    2/6

  • 8/4/2019 Coleman FPSE Manual

    3/6

    43

    Features

    Warning

    Lid Opening/Closing mechanism

    Operating Panel

    Handle Lid

    Press downLid Latch

    Air outlet vent Air intake area

    FilterDC power socket

    FREEZE-2

    Temperature setting indicators flash.Power button

    Power indicator

    Low-battery light

    Warning light

    COOL-1Cools the Power Cooler toapproximately 50F (10C)

    COOL-2Cools the Power Cooler toapproximately 43F (6C)

    FREEZE-1Cools the Power Cooler toapproximately 19F (-7C)

    Cools the Power Cooler toapproximately -0.4F (-18C)

    Cools the Power Cooler to approximately 37F (3C)COOL-3

    Power Cable and Power Supply

    Opening/Closing the lid

    Lid open Opening the lid Closing the lid

    Powerplug

    HouseholdPower Supply

    DC plug

    DCPower Cable

    The lid is equipped with a mechanism that prevents the lid

    from closing quickly. If the lid is half open, the mechanismwill not operate properly, and the lid may shut forcefully un-der its own weight. Therefore, open the lid completely to ac-tivate the mechanism.

    Pull up

    To avoid malfunction, the switches will only operate after being pressed for approximately one second. Continue to

    press until a high-pitched tone is emitted.

    Press and hold the power buttonto turn the power on or off. When the temperature in the cooler reaches

    the set temperature, the flashing lights changeto continuous illumination.

    (5232F640T)(5726-3661)

    Do not operate the product in extremely hot or cold environment (see page 10 forrecommended operating temperature range). If the cooler internal air temperaturedrops below -40F(-40C) or rises above 140F(60C), the "on/off" light, "Freeze-1" light, and "Freeze-2" light will allflash, warning users to immediately turn off the product and correct the extreme temperature condition. The cooler canbe turned back on once the ambient temperature condition is within the recommended range and the cooler internal airtemperature rises above -40F(-40C) or drops below 140F (60C).

    The low-battery light flashes when the input voltage is low. Use the light tocheck the battery condition.

    The warning light illuminates when the temperature of the unitscooling system rises.

    If the warning light illuminates, remove any objects blocking the air intake areaor air outlet vent. Make sure that the filter is clean. If it is dirty, perform mainte-nance (see page 8). Make sure the unit is located in an environment below120F. When the environment returns to normal, the warning light will shut off.

  • 8/4/2019 Coleman FPSE Manual

    4/6

  • 8/4/2019 Coleman FPSE Manual

    5/6

  • 8/4/2019 Coleman FPSE Manual

    6/6

    109

    SpecificationsTo StoreOperating voltage

    Power consumption

    Cooling temperature whenempty (approx.)

    Operating temperature range

    Usable capacity

    Dimensions (approx.)

    Weight (approx.)

    DC Power Cable

    (5726-3661)Household Power Supply

    (5232F640T)

    1. Switch the unit off using power button and disconnect the power plug.2. Remove any items being stored in the cooler. Clean inside and outside of the cooler with a damp cloth.

    Wipe off any moisture and allow it to thoroughly dry.3. To refresh the air in the cooler, open the lid occasionally or place an open box of baking soda to absorb odors.

    12 VDC

    12 VDC, 48W (4A)

    -0.4F to 50F (-18C to 10C)( ambient temp.: 86F (30C) )

    32F to 104F (0C to 40C)

    0.88 cu.ft (25 liters)

    27.3" (695 mm) W x 18.1" (460 mm) H x 13.7" (350 mm) D

    33 lbs (15 kg)

    9.8 ft (3 m)

    Converts 120 VAC to 12 VDC, 5A

    Troubleshooting Please check the following pointsbefore contacting Coleman for repairs.Problem Possible Cause Solution

    On/Off button has not been pressedcontinuously for 1 second.

    Push the button until you hear a high-pitched tone (approximately 1 second).

    There are ashes or dust in the powersupply socket.

    Clean the power supply socket.

    Electrical connections are notproperly connected.

    Check electrical connections.

    The lid is not completely closed. Close the lid properly and lock it.

    The air vents are covered. Check both the air intake and the air outletvents. Remove any items covering the vents.

    The lid is being opened and closedtoo often.

    Minimize opening and closing of the lid.

    The filter is clogged. Perform filter maintenance on Page 8.

    Remove some of the items from the cooler.

    Contact The Coleman Company, Inc. Do notreplace the fuse yourself. An improper fusewill damage the product and void the war-ranty. When installing the new DC power ca-

    ble, make sure the polarity is not reversed.

    The unit is exposed to direct sunlight,is too close to a heat source, or isbeing operated in an excessively hotenvironment.

    Change the location of the unit.

    A car fuse has blown.

    The low-battery light is flashing. Check the battery condition.

    The DC power cable fuse or the PCboard fuse has blown due to reversedpolarity.

    Vehicle: turn on engine.

    Household: check circuit brakersNo power to cooler.

    There are too many items in thecooler, obstructing air circulation.

    Replace the fuse.

    Unit doesnot turn