4
COLD AIR SEEPING FROM AN URBAN GREEN SPACE, IMPERIAL PALACE, IN CENTRAL TOKYO Ken-ichi Narita* 1 , Hirofumi Sugawara* 2 , Hitoshi Yokoyama* 3 , Ikusei Misaka* 4 and Dai Matsushima* 5 * 1 Nippon Institute Technology, Saitama, Japan; * 2 National Defense Academy, Kanagawa, Japan * 3 Tokyo Metropolitan Research Institute for Environmental Protection, Tokyo, Japan * 4 R&D Institute, Takenaka Corporation, Chiba, Japan;* 5 Chiba Institute of Technology, Chiba, Japan Abstract In this paper, results are shown from micro-climatological observations performed in and around a largest green space in central Tokyo, “Imperial Palace”, during summer. Air temperature was measured at 1-minute intervals between the boundary of the green space and the Tokyo Station. In order to catch the phenomena of cold air seeping-out in calm conditions, several sonic anemometers were set along the green space boundary. In a clear calm night, flow-out wind directions from green spaces to surrounding built-up areas were discerned at all measuring points. The obvious shift of wind direction appeared at the beginning of the flow-out with a sharp temperature fall of 1 or 2 degrees. Key words: radiative cooling, cold air drainage, urban park 1. INTRODUCTION The mitigation effect of green space in urban area has been expected to be comparable to that of water surfaces. In Japan, its cooling effect in hot and humid summer is especially important and it is considered as an important method available for city planning. In a clear calm night, ground inversion layer is formed in a green space by radiative cooling, and some accumulated cold air near green surface flows out gravitationally into surrounding city area. Such “cold air seeping” was firstly observed in “Shinjyuku-Gyoen Park” in Tokyo (Narita et al. 2002, Honjyo et al. 2003 and Narita et al. 2004). Different from the daytime advection by prevailing wind, the turbulent mixing is very weak in nighttime seeping phenomena because of the stable atmospheric condition. Therefore, the cooling effect for ambient air, that is the negative sensible heat flux, was very small, but the flow-out air was kept cool as far as the seeping front, 80-90 m from the boundary in that case. In this paper, results are shown from micro-climatological observations performed in and around a largest green space in central Tokyo, “Imperial Palace”, during summer. It was once the Edo-Castle, then surrounded by a moat. Its area is 230ha, and it located adjacent to one of the main CBD, “Maru-no-uchi”, which includes Tokyo Station. The topography around the Imperial Palace is inclined toward east; the elevation of west side is 25 m higher than east side. Then, the east side water surface in the moat is only few meters lower than ground level, but the depth of west side moat is more than 20 m. The core area of the Imperial Place is covered by dense forest. 2. OBSERVATION METHODS The observations were performed during summer in 2007 and 2008. The main purpose in 2008 was to make clear the effect of topography on the cold air seeping, and that in 2007 was to grasp the seeping front in east side CBD area. Air temperature was measured at 1-minute intervals at totally 27 points in and around the Imperial Palace including west side moat slope in 2008 (Fig. 1), and at totally 50 points between the east side boundary of the green space and the Tokyo Station in 2007. In order to catch the cold air seeping-out in calm conditions, several sonic anemometers were set along the green space boundary in 2008, and also in adjacent built up area in 2007. Measuring height was 2.5m above the ground and sampling frequency 1Hz. In addition, the vertical air temperature profile was measured using a lift car in 2007 to reveal the depth of seeping-out cold air. Fig.1 Observation points around Imperial Palace. *Corresponding author address; Ken-ichi Narita, Department of Architecture, Nippon Institute of Technology, Gakuen-dai, 4-1, Miyashiro, Saitama, Japan; e-mail: [email protected] Imperial Palace S2 S1 S7 S6 S5 S4 S3 S8 S9 S10 S11 S12 S13 S14 S15 S16 F1 P15 C15 Thermometer Sonic (within palace) Sonic anemometer Slope Temp. Water Temp. Sakashita Gate The seventh International Conference on Urban Climate, 29 June - 3 July 2009, Yokohama, Japan

COLD AIR SEEPING FROM AN URBAN GREEN SPACE, IMPERIAL ... › ~icuc7 › extended_abstracts › pdf › 422625-1... · IMPERIAL PALACE, IN CENTRAL TOKYO Ken-ichi Narita*1, Hirofumi

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • COLD AIR SEEPING FROM AN URBAN GREEN SPACE, IMPERIAL PALACE, IN CENTRAL TOKYO

    Ken-ichi Narita*1, Hirofumi Sugawara*2, Hitoshi Yokoyama*3, Ikusei Misaka*4 and Dai Matsushima*5 *1Nippon Institute Technology, Saitama, Japan; *2National Defense Academy, Kanagawa, Japan

    *3 Tokyo Metropolitan Research Institute for Environmental Protection, Tokyo, Japan *4 R&D Institute, Takenaka Corporation, Chiba, Japan;*5 Chiba Institute of Technology, Chiba, Japan

    Abstract In this paper, results are shown from micro-climatological observations performed in and around a largest green space in central Tokyo, “Imperial Palace”, during summer. Air temperature was measured at 1-minute intervals between the boundary of the green space and the Tokyo Station. In order to catch the phenomena of cold air seeping-out in calm conditions, several sonic anemometers were set along the green space boundary. In a clear calm night, flow-out wind directions from green spaces to surrounding built-up areas were discerned at all measuring points. The obvious shift of wind direction appeared at the beginning of the flow-out with a sharp temperature fall of 1 or 2 degrees. Key words: radiative cooling, cold air drainage, urban park 1. INTRODUCTION The mitigation effect of green space in urban area has been expected to be comparable to that of water surfaces. In Japan, its cooling effect in hot and humid summer is especially important and it is considered as an important method available for city planning. In a clear calm night, ground inversion layer is formed in a green space by radiative cooling, and some accumulated cold air near green surface flows out gravitationally into surrounding city area. Such “cold air seeping” was firstly observed in “Shinjyuku-Gyoen Park” in Tokyo (Narita et al. 2002, Honjyo et al. 2003 and Narita et al. 2004). Different from the daytime advection by prevailing wind, the turbulent mixing is very weak in nighttime seeping phenomena because of the stable atmospheric condition. Therefore, the cooling effect for ambient air, that is the negative sensible heat flux, was very small, but the flow-out air was kept cool as far as the seeping front, 80-90 m from the boundary in that case. In this paper, results are shown from micro-climatological observations performed in and around a largest green space in central Tokyo, “Imperial Palace”, during summer. It was once the Edo-Castle, then surrounded by a moat. Its area is 230ha, and it located adjacent to one of the main CBD, “Maru-no-uchi”, which includes Tokyo Station. The topography around the Imperial Palace is inclined toward east; the elevation of west side is 25 m higher than east side. Then, the east side water surface in the moat is only few meters lower than ground level, but the depth of west side moat is more than 20 m. The core area of the Imperial Place is covered by dense forest.

    2. OBSERVATION METHODS The observations were performed during summer in 2007 and 2008. The main purpose in 2008 was to make clear the effect of topography on the cold air seeping, and that in 2007 was to grasp the seeping front in east side CBD area. Air temperature was measured at 1-minute intervals at totally 27 points in and around the Imperial Palace including west side moat slope in 2008 (Fig. 1), and at totally 50 points between the east side boundary of the green space and the Tokyo Station in 2007. In order to catch the cold air seeping-out in calm conditions, several sonic anemometers were set along the green space boundary in 2008, and also in adjacent built up area in 2007. Measuring height was 2.5m above the ground and sampling frequency 1Hz. In addition, the vertical air temperature profile was measured using a lift car in 2007 to reveal the depth of seeping-out cold air.

    Fig.1 Observation points around Imperial Palace.

    *Corresponding author address; Ken-ichi Narita, Department ofArchitecture, Nippon Institute of Technology, Gakuen-dai, 4-1, Miyashiro, Saitama, Japan; e-mail: [email protected]

    Imperial Palace

    S2S1

    S7

    S6

    S5 S4S3

    S8

    S9

    S10

    S11

    S12 S13S14

    S15

    S16

    F1

    P1~5

    C1~5

    ThermometerSonic (within palace)Sonic anemometer

    Slope Temp.

    Water Temp.

    Sakashita Gate

    Imperial Palace

    S2S1

    S7

    S6

    S5 S4S3

    S8

    S9

    S10

    S11

    S12 S13S14

    S15

    S16

    F1

    P1~5

    C1~5

    ThermometerSonic (within palace)Sonic anemometer

    Slope Temp.

    Water Temp.

    Sakashita Gate

    The seventh International Conference on Urban Climate, 29 June - 3 July 2009, Yokohama, Japan

  • 3. RESULTS Observation period in 2008 was totally 65 days from July 27 to September 29. The weather condition of this period was rather anomalous, the number of no rainfall day amounts only 19. Figure 2 shows the example of seeping-out phenomena of cold air in calm clear night around Imperial Palace. At east-side point (S16), wind direction is almost fixed in north-west after 22:00 on Aug. 14. At the west-side inner point (F1), obvious shift of wind direction appeared at 1:00 on Aug. 15 with a sharp temperature fall of 2 degrees. Before this event, time variation of temperature and wind direction is similar to that of the east-side. These imply the westerly wind after 22:00 was synoptic scale phenomena and it resulted in rather rapid temperature drop at all measuring points. Then, three hours later (at 1:00), this westerly wind became weak and cold air drainage from the Imperial Palace was started even in the west side. The wind directions at 1:30 at each sonic point show the cold air flows out to the surrounding city area for all direction (illustrated by arrows in Figure 2). While there was no traffic near the points (F1) and (S16), the other four sonic anemometers were clung to the roadside light poles and probably affected by traffic disturbance. That is the reason why the wind direction was fluctuated and the sharp temperature drop was not so clear at these points. In order to examine the topographic effect of the deep moat, we focused the difference between inner side point (F1) and outer side point (S7) of the west side moat. In the outer side, the magnitude of sharp temperature drop became smaller than that of the inner side, but there can be seen no significant time lag in both side temperature time-variations. This suggested that the cold air from the Imperial Place flows across the deep moat at once; it dose not constitute the barriers against the cold air seeping.

    Outer Slope

    25

    26

    27

    28

    29

    30

    31

    32

    8/1418

    8/1419

    8/1420

    8/1421

    8/1422

    8/1423

    8/150

    8/151

    8/152

    8/153

    8/154

    8/155

    8/156

    Air

    Tem

    p. �

    ��

    Water Temp.

    A�e�A�S9

    C5C3

    C1 1.5m7.5m

    7.5m

    7.5m

    7.5 m

    S9

    C5C4

    C3

    C2

    C11.5m7.5m

    7.5m

    7.5m

    7.5 m

    S9

    C5C4

    C3

    C2

    C1

    Fig.3 Time variation of air temperature along the moat slope.

    25

    26

    27

    28

    29

    30

    31

    32

    33

    8/1418

    8/1419

    8/1420

    8/1421

    8/1422

    8/1423

    8/150

    8/151

    8/152

    8/153

    8/154

    8/155

    8/156

    Air

    Tem

    p���

    0

    1

    2

    3

    4

    5

    6

    7

    8

    Win

    d S

    peed

    (m/s

    )

    N

    W

    S

    E

    N

    Air Temp.

    Wind Speed

    Wind Direc.

    Water Temp.

    25

    26

    27

    28

    29

    30

    31

    32

    33

    8/1418

    8/1419

    8/1420

    8/1421

    8/1422

    8/1423

    8/150

    8/151

    8/152

    8/153

    8/154

    8/155

    8/156

    Air

    Tem

    p���

    0

    1

    2

    3

    4

    5

    6

    7

    8

    Win

    d S

    peed

    (m/s

    )

    N

    W

    S

    E

    N

    25

    26

    27

    28

    29

    30

    31

    32

    33

    8/1418

    8/1419

    8/1420

    8/1421

    8/1422

    8/1423

    8/150

    8/151

    8/152

    8/153

    8/154

    8/155

    8/156

    Air

    Tem

    p���

    0

    1

    2

    3

    4

    5

    6

    7

    8

    Win

    d S

    peed

    (m/s

    )

    N

    W

    S

    E

    N

    25

    26

    27

    28

    29

    30

    31

    32

    33

    8/1418

    8/1419

    8/1420

    8/1421

    8/1422

    8/1423

    8/150

    8/151

    8/152

    8/153

    8/154

    8/155

    8/156

    Air

    Tem

    p���

    0

    1

    2

    3

    4

    5

    6

    7

    8

    Win

    d S

    peed

    (m/s

    )

    N

    W

    S

    E

    N

    25

    26

    27

    28

    29

    30

    31

    32

    33

    8/1418

    8/1419

    8/1420

    8/1421

    8/1422

    8/1423

    8/150

    8/151

    8/152

    8/153

    8/154

    8/155

    8/156

    Air

    Tem

    p���

    0

    1

    2

    3

    4

    5

    6

    7

    8

    Win

    d S

    peed

    (m/s

    )

    N

    W

    S

    E

    N

    Air Temp.

    Wind Speed

    Wind Direc.

    Wind direction at 1:30, Aug. 15

    S5

    S7

    S11

    S1

    F1

    25

    26

    27

    28

    29

    30

    31

    32

    33

    8/1418

    8/1419

    8/1420

    8/1421

    8/1422

    8/1423

    8/150

    8/151

    8/152

    8/153

    8/154

    8/155

    8/156

    Air

    Tem

    p���

    �0

    1

    2

    3

    4

    5

    6

    7

    8

    Win

    d S

    peed

    (m/s

    )

    N

    W

    S

    E

    N

    S16

    Fig.2 Seeping-out phenomena of cold air in calm night-1-minute average time variations of air temperature, wind speed and direction at boundary points.

    The seventh International Conference on Urban Climate, 29 June - 3 July 2009, Yokohama, Japan

  • Figure 3 shows the comparison of air temperature variation at the points along the outer slope. At road side point (S9), the sharp temperature drop appeared clearly just after 1:00. On the slope (C1~C5), the temperature decreased gradually from the time about one hour earlier than road side steep change. Notice the water temperature in Figure 3. This moat has no sufficient inflow, so natural rain is the only water supply. Consequently, water temperature was higher than air temperature during the night; exceeded 30 degrees Centigrade even early in the morning. Nevertheless, the air temperature was lowest in the bottom of slope, that is, the ground inversion layer was formed in the moat valley. The occurrence of cold air seeping phenomena is limited in calm night, so the turbulent heat exchange at the water surface is considered very weak. Figure 4 is the result in 2007, focused on the seeping front in “Maru-no-uchi” CBD area. Three figures show the 1-minute average time variations of air temperature, wind speed and direction, as same manner as Figure 2. The upper graph is the result of point (S16) that is common to the observation in 2008. In this night, cold air seeping was started about at 0:50. At the point beyond the moat (middle graph), and at the edge of CBD beyond the Route 1 (lower graph), the start of temperature drop appeared later than point (S16). Figure 5 shows the temperature field during 3:00~4:00, when cold air expanded most broadly. The arrows in the figure express the wind directions at each sonic point. To investigate the effect of the moat and wide-street on the seeping of cold air in detail, the isopleths between the Imperial Palace (Sakashita Gate) and the Tokyo Station were drawn in Figure 6. Here, the color means a temperature difference from the area-averaged temperature around Tokyo Station. Within the “Kokyo Gaien National Garden”, cold air spread out rapidly. However, the beginning of invasion of seeping front into CBD area was about two hours later. After that, the cold air front penetrated the CBD area and reached near the Tokyo Station. According to the sonic data of wind direction change, there was not so large time-lag until the front passed across the moat. These results suggested that the wide street have a relatively large effect on cold air seeping than the moat even though water temperature was higher than ambient air temperature. Figure 7 is the time-height isopleths drawn using vertical temperature profile collected by a lift car. Here, temperature was expressed as a difference from the upper layer air temperature at the height of 110 meters. This special observation was carried out for three days, and cold air seeping occurred only one night during these period. At the time of most strongly cooled period, air temperature was lower than reference upper layer up to the height of 14 m. Even the top height (25 m above the ground), the effect of cold air seeping was discernible clearly. 4. CONCLUSIONS In a clear calm night, the cold air flows out from the Imperial Palace to the surrounding city area gravitationally. In the west side, it flows over the valley of moat (20m depth) and spread out into the built-up area. In the east side, cold air front sometimes penetrate the adjacent CBD area and reached near the Tokyo Station.

    Fig.5 Temperature field and wind direction when seeping-out phenomena appeared.

    Fig.4 Seeping-out phenomena of cold air in the east side of Imperial Palace. (same manner as Figure 2)

    252627282930313233

    18 19 20 21 22 23 0 1 2 3 4 5 6

    Air

    Tem

    p.(℃

    )

    012345678

    Win

    d Sp

    eed(

    m/s

    )

    W

    N

    S

    E

    N

    252627282930313233

    18 19 20 21 22 23 0 1 2 3 4 5 6

    Air

    Tem

    p.(℃

    )

    012345678

    Win

    d Sp

    eed(

    m/s

    )

    W

    N

    S

    E

    N

    252627282930313233

    18 19 20 21 22 23 0 1 2 3 4 5 6

    Air

    Tem

    p.(℃

    )

    012345678

    Win

    d S

    peed

    (m/s

    )

    W

    N

    S

    E

    N

    Aug. 9~102007

    0 300m

    S16

    Wind Speed

    Air Temp. Wind Dire.

    Water Temp.

    252627282930313233

    18 19 20 21 22 23 0 1 2 3 4 5 6

    Air

    Tem

    p.(℃

    )

    012345678

    Win

    d Sp

    eed(

    m/s

    )

    W

    N

    S

    E

    N

    252627282930313233

    18 19 20 21 22 23 0 1 2 3 4 5 6

    Air

    Tem

    p.(℃

    )

    012345678

    Win

    d Sp

    eed(

    m/s

    )

    W

    N

    S

    E

    N

    252627282930313233

    18 19 20 21 22 23 0 1 2 3 4 5 6

    Air

    Tem

    p.(℃

    )

    012345678

    Win

    d S

    peed

    (m/s

    )

    W

    N

    S

    E

    N

    Aug. 9~102007

    0 300m0 300m

    S16

    Wind SpeedWind Speed

    Air Temp.Air Temp. Wind Dire.Wind Dire.

    Water Temp.

    The seventh International Conference on Urban Climate, 29 June - 3 July 2009, Yokohama, Japan

  • References Narita, K., Mikami, T., Sugawara, H., Honjo, T., Kimura, K. and Kuwata, N., 2002.Observation about cool-island phenomena in urban park, AMS 4th Symposium on the Urban Environment (Norfolk, VN, USA), 86-87. Honjo, T., Narita, K., Mikami, T., Sugawara, H., Kimura, K. and Kuwata, N., 2003. Observation of Cool Island Effect in Urban Park (Shinjuku Gyoen), Proceedings of ICUC-5 (Lodz, Poland), Vol.2, 261-264 Narita, K., Mikami, T., Sugawara, H., Honjo, T., Kimura, K. and Kuwata, N., 2004. Cool-island and cold air-seeping phenomena in an urban park, Shinjyuku Gyoen, Tokyo, Geographical Review of Japan, 77, 403-420. (in Japanese with a English summary) Sugawara, H.,Tanaka, T., Narita, K., Nakano, T. And Mikami, T., 2008. How much cool air dose an urban green park produce? Geographical reports of Tokyo Metropolitan University, 43, 83-89. Observational study of the heat island - Cooling effect of urban park, 2008. Newsletter of urban heat island countermeasure, AIJ, Vol.3. (http://news-sv.aij.or.jp/tkankyo/s3/Newsletter_vol3_081118.pdf)

    Profile

    Sonic

    S16

    0 5 10 15 20 25 30 35 40 45 50 55 6002468

    1012141618202224

    heig

    ht (m

    )

    024681012141618202224

    18 19 20 21 22 23 0 1 2 3 4 5 6Time (JST) [h]

    S16

    222324252627282930

    18 19 20 21 22 23 0 1 2 3 4 5 6

    Air

    Tem

    p.(℃

    )

    012345678

    Win

    hd S

    peed

    (m/s

    ) W

    N

    S

    E

    NAir Temp.

    Wind Speed

    Wind Direc.

    Aug. 6~7 2007

    Fig.7 Depth of cold air seeping from Imperial Palace.

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 60000

    200

    400

    600

    Dis

    tanc

    e(m

    )

    N

    25

    27

    29

    31

    33

    18 19 20 21 22 23 0 1 2 3 4 5 6

    Air

    Tem

    p.(℃

    )

    0

    1

    2

    3

    4

    Win

    d Sp

    eed(

    m/s

    )Wind Direc.

    Wind Speed

    Air Temp.W

    S

    N

    E

    N

    25

    27

    29

    31

    33

    18 19 20 21 22 23 0 1 2 3 4 5 6A

    ir Te

    mp.

    (℃)

    0

    1

    2

    3

    4

    Win

    d S

    peed

    (m/s

    )

    Air Temp.

    Wind Direc.

    Wind Speed

    W

    S

    N

    E

    N

    1� 1� 20 21 22 23 0 1 2 3 4 5 6

    -3.8

    -3.4

    -3.0

    -2.6

    -2.2

    -1.8

    -1.4

    -1.0

    -0.6

    -0.2

    ���������

    �������������������������

    ������������ �������������

    Water Temp.

    �������������

    ���������������

    ������������

    ������1

    ��������������

    �����������N��������������

    �������������������������℃�

    ��������������

    �����

    �������

    Fig.6 Air temperature difference isopleths between Imperial Palace and Tokyo Station.

    Aug. 9~10 2007

    The seventh International Conference on Urban Climate, 29 June - 3 July 2009, Yokohama, Japan