OPEN FRONT BOOTH
OVERVIEWThe Open Front Booth is designed for both batch type and conveyorized production systems. Air flow is drawn in through the
open front, across the work area and exhausted through a filter bank in the back of the booth. The dry arrestor filters trap the
airborne overspray particles before the filtered air is discharged through the exhaust system and into the atmosphere. The booths
are available in a wide range of designs to meet practically any production requirement. Conveyor pass-through openings can be
as much as 25% of the booth open front area, without requiring additional exhaust fan capacity. Specially engineered enclosures
may be designed to meet your requirements. Air replacement units and intake chambers can be added as well as reduced air flows
for automatic spray operations.
LIGHTING FEATURESLighted booths provide a bright, full booth illumination from four-tube, 48" long, 32-watt, fluorescent light fixtures. All fixtures are UL
listed and approved for their intended use and placement. The light tubes are furnished with Class I Division II sealed and gasketed
fixtures.
electric components can
be purchased separately
control panel is added
A tubeaxial exhaust fan designed specifically for use in
paint spray booths powers the airflow, through the booth
and exhaust stack. All exhaust fans are of non-sparking
construction.The motor drive and bearings are sealed
from the air stream of the exhaust. Motors are provided
with each unit.
prime-quality steel
are precision punched for easy
nut and bolt assembly
Industrial Auto Wood
Model Interior Dimensions Exterior Dimensions Qty. Qty. Fan Fan SCFM @ ShippingNumber Width Height Length Width Height Length Lights Filters Diameter HP 1/2” SP Weight IB-04-07-05 4’-0" 7’-0" 5’-0" 4’-4” 7’-2” 7’-2” 0 8 18” .75HP 3,500 675IB-06-07-05 6’-0" 7'-0" 5’-0" 6’-4” 7’-2” 7’-8” 1 12 24” 1HP 5,250 940IB-08-07-05 8’-0" 7'-0" 5’-0" 8’-4” 7’-2” 7’-8” 1 16 24” 2HP 7,150 1,240IB-10-07-05 10’-0" 7'-0" 5’-0" 10’-4” 7’-2” 8’-2” 2 20 30” 2HP 8,750 1,630IB-12-07-07 12’-0" 7'-0" 7’-0" 12’-4” 7’-2” 10’-2” 2 24 30” 3HP 10,500 1,870IB-14-07-07 14’-0" 7'-0" 7’-0" 15’-0” 7’-6” 10’-8” 2 32 30” 3HP 12,250 2,450IB-16-07-07 16’-0" 7'-0" 7’-0" 17’-0” 7’-6” 10’-8” 2 36 30” 5HP 14,000 2,650IB-18-07-07 18’-0" 7'-0" 7’-0" 19’-0” 7’-6” 11’-8” 3 40 36” 5HP 15,750 3,000 IB-20-07-07 20’-0" 7’-0" 7’-0" 21’-0” 7’-6” 11’-8” 4 44 36” 5HP 17,500 3,540
IB-04-08-05 4’-0" 8’-0" 5’-0" 4’-4” 8’-2” 7’-2” 0 8 18” .75HP 4,000 703IB-06-08-05 6’-0" 8’-0" 5’-0" 6’-4” 8’-2” 7’-8” 1 12 24” 1.5HP 6,000 1,020IB-08-08-05 8’-0" 8’-0" 5’-0" 8’-4” 8’-2” 7’-8” 1 16 24” 2HP 8,000 1,490IB-10-08-05 10’-0" 8’-0" 5’-0" 10’-4” 8’-2” 8’-2” 2 20 30” 3HP 10,000 1,780IB-12-08-07 12'-0" 8’-0" 7’-0" 12’-4” 8’-2” 10’-2” 2 24 30” 3HP 12,000 2,270IB-14-08-07 14’-0" 8’-0" 7’-0" 15’-0” 8’-6” 10’-8” 2 32 30” 5HP 14,000 2,600IB-16-08-07 16’-0" 8’-0" 7’-0" 17’-0” 8’-6” 11’-8” 2 36 36” 5HP 16,000 2,810 IB-18-08-07 18’-0" 8’-0" 7’-0" 19’-0” 8’-6” 11’-8” 3 40 36” 5HP 18,000 3,150IB-20-08-07 20’-0" 8’-0" 7’-0" 21’-0” 8’-6” 11’-8” 4 44 42” 5HP 20,000 3,690
IB-04-10-05 4’-0" 10’-0" 5’-0" 4’-4” 10’-2” 7’-2” 0 10 18” 1.5HP 5,000 1,100IB-06-10-05 6’-0" 10’-0" 5’-0" 6’-4” 10’-2” 7’-8” 1 15 24” 2HP 7,500 1,650IB-08-10-05 8’-0" 10’-0" 5’-0" 8’-4” 10’-2” 8’-2” 1 20 30” 2HP 10,000 1,900IB-10-10-05 10’-0" 10’-0" 5’-0" 10’-4” 10’-2” 8’-2” 2 25 30” 3HP 12,500 2,350IB-12-10-07 12’-0" 10’-0" 7’-0" 12’-4” 10’-2” 10’-2” 2 30 30” 5HP 15,000 2,500IB-14-10-07 4’-0" 10’-0" 7’-0" 15’-0” 10’-6” 11’-8” 2 40 36” 5HP 17,500 3,000IB-16-10-07 16’-0" 10’-0" 7’-0" 17’-0” 10’-6” 11’-8” 2 45 42” 5HP 20,000 3,400IB-18-10-07 18’-0" 10’-0" 7’-0" 19’-0” 10’-6” 11’-8” 3 50 42” 5HP 22,500 4,000IB-20-10-07 20’-0" 10’-0" 7’-0" 21’-0” 10’-6” 11’-8” 4 55 42” 7.5HP 25,000 4,400
IB-04-12-05 4’-0" 12’-0" 5’-0" 4’-4” 12’-2” 7’-8” 0 12 24” 1.5HP 6,000 975IB-06-12-05 6’-0" 12’-0" 5’-0" 6’-4” 12’-2” 7’-8” 1 18 24” 3HP 9,000 1,500IB-08-12-05 8’-0" 12’-0" 5’-0" 8’-4” 12’-2” 8’-2” 1 24 30” 3HP 12,000 1,700IB-10-12-05 10’-0" 12’-0" 5’-0" 10’-4” 12’-2” 8’-2” 2 30 30” 5HP 15,000 2,200IB-12-12-07 12’-0" 12’-0" 7’-0" 12’-4” 12’-2” 11’-2” 2 36 36” 5HP 18,000 2,500IB-14-12-07 14’-0" 12’-0" 7’-0" 15’-0” 12’-6” 11’-8” 2 48 42” 5HP 21,000 3,200IB-16-12-07 16’-0" 12’-0" 7’-0" 17’-0” 12’-6” 11’-8” 2 54 42” 7.5HP 24,000 3,500IB-18-12-07 18’-0" 12’-0" 7’-0" 19’-0” 12’-6” 11’-8” 3 60 42” 7.5HP 27,000 4,100IB-20-12-07 20’-0" 12’-0" 7’-0" 21’-0” 12’-6” 11’-8” 4 66 42” 10HP 30,000 4,700
OPEN FRONT BOOTH
Ref. Key A B C D
Industrial Auto Wood
Col-Met Spray Booths - Rockwall, TX // e-mail: [email protected] - Toll-free: 888.452.6684 // www.colmetsb.com
OPEN FRONT BENCH BOOTH
OVERVIEWThe Open Front Bench Booth is designed for both batch type and conveyorized production systems. Air flow is drawn in through the open front, across the painter and parts being coated and exhausted through a filter bank in the back of the booth. The dry arrestor filters trap the airborne overspray particles before the filtered air is discharged through the exhaust system and into the atmosphere. The booths are available in a wide range of designs to meet practically any production requirement. Conveyor pass through openings can be as much as 25% of the booth open front area, without requiring additional exhaust fan capacity. Specially engineered enclosures may be designed to meet your requirements. Air replacement units and intake chambers can be added as well as reduced air flows for automatic spray operations.LIGHTING FEATURESLighted booths provide a bright, full booth illumination from four-tube, 48" long, 32-watt, fluorescent light fixtures. Each is Class I, Division II, sealed and gasketed construction. All fixtures are UL listed and approved for their intended use and placement. The light tubes are furnished with Class I Division II sealed and gasketed fixtures.
electric components can be purchased separately control panel is added
EXHAUST SYSTEM FEATURESA tubeaxial exhaust fan designed specifically for use in paint spray booths powers the airflow through the booth and exhaust stack. All exhaust fans are of non-sparking construction. The motor drive and bearings are sealed from the air stream of the exhaust. Motors are provided with each unit.
prime-quality steel are precision punched for easy nut and bolt assembly
Industrial Auto Wood
Ref. Key A B C D
* Optional 36", two-tube light fixture available.
Model Interior Dimensions Exterior Dimensions Qty. Qty. Fan Fan SCFM @ ShippingNumber Width Height Length Width Height Length Lights Filters Diameter HP 1/2" SP
IBB-04-07-02 4'-0" 4'-0" 2'-0" 4'-4" 7'-2" 4'-2" 0* 4 18" .75HP 2,000 675IBB-05-07-03 5'-0" 4'-0" 3'-0" 5'-4" 7'-2" 5'-2" 1 4 18" .75HP 2,500 940IBB-06-07-03 6'-0" 4'-0" 3'-0" 6'-4" 7'-2" 5'-2" 1 6 18" .75HP 3,000 1,240IBB-08-07-03 8'-0" 4'-0" 3'-0" 8'-4" 7'-2" 5'-2" 1 8 18" 1 HP 4,000 1,630IBB-10-07-03 10'-0" 4'-0" 3'-0" 10'-4' 7'-2" 5'-2" 2 10 18" 1.5 HP 5,000 1,870IBB-12-07-03 12'-0" 4'-0" 3'-0" 12'-4" 7'-2" 5'-8" 2 12 24" 1.5 HP 6,000 2,450
OPEN FRONT BENCH BOOTH
Industrial Auto Wood
ENCLOSED INDUSTRIAL BOOTH
Industrial Auto Wood
OVERVIEWAir flows in through the filtered double entry doors in the front of the booth, passes through the booth’s working area, and into the filtered exhaust chamber located in the rear of the booth. This filtered exhaust air is drawn through the exhaust plenum anddischarged upward into the atmosphere through the exhaust stack. Our Industrial Enclosure booths make efficient use of your valuable floor space and are available in four heights to accommodate your needs.LIGHTING FEATURESBright, full-booth illumination is provided by four 48 , four-tube, 32-watt fluorescent light fixtures placed in the ceiling panels and side walls. Each is sealed behind clear tempered safety glass. All fixtures are UL listed and approved for their intended use and placement.
electric components can be purchased separately control panel is added
prime-quality steel are precision punched for easy nut and bolt assembly
doors are pre-hung in a heavy gauge galvanized steel frame for easy installation.on slotted hinges to facilitate
OR
CROSSDRAFT
MODIFIED DOWNDRAFT
Col-Met Spray Booths - Rockwall, TX // e-mail: [email protected] - Toll-free: 888.452.6684 // www.colmetsb.com
Interior Dimensions Exterior Dimensions Nominal Door Opening Qty. Filters Fan Fan SCFM @ Width Height Length Width Height Length Width Height Qty Type Lights Exhaust Diameter HP 1/2” SP 10’-0" 7’-0" 5’-0" 10’-4” 7’-2” 7’-10” 9'-4" 6'-10.5" 1 Filtered 2 20 24” 2HP 7,000 12’-0" 7’-0" 7’-0" 12’-4” 7’-2” 9’-10” 11'-4" 6'-10.5" 1 Filtered 2 24 24” 3HP 8,400 14’-0" 7’-0" 7’-0" 15’-0” 7’-6” 10’-8” 13'-4" 6'-10.5" 1 Filtered 2 32 30” 3HP 9,800 16’-0" 7’-0" 7’-0" 17’-0” 7’-6” 10’-8” 13'-4" 6'-10.5" 1 Filtered 2 36 30” 3HP 11,200 18’-0" 7’-0" 7’-0" 19’-0” 7’-6” 10’-8” 13'-4" 6'-10.5" 1 Filtered 3 40 30” 3HP 12,600 20’-0" 7’-0" 7’-0" 21’-0” 7’-6” 10’-8” 13'-4" 6'-10.5" 1 Filtered 4 44 30” 5HP 14,000
10’-0" 8’-0" 5’-0" 10’-4” 8’-2” 7’-10” 9'-4" 7'-10.5" 1 Filtered 2 20 24” 3HP 8,000 12'-0" 8’-0" 7’-0" 12’-4” 8’-2” 10’-4” 11'-4" 7'-10.5" 1 Filtered 2 24 30” 3HP 9,600 14’-0" 8’-0" 7’-0" 15’-0” 8’-6” 10’-8” 13'-4" 7'-10.5" 1 Filtered 2 32 30” 3HP 11,200 16’-0" 8’-0" 7’-0" 17’-0” 8’-6” 10’-8” 13'-4" 7'-10.5" 1 Filtered 2 36 30” 5HP 12,800 18’-0" 8’-0" 7’-0" 19’-0” 8’-6” 10’-8” 13'-4" 7'-10.5" 1 Filtered 3 40 30” 5HP 14,400 20’-0" 8’-0" 7’-0" 21’-0” 8’-6” 11’-8” 13'-4" 7'-10.5" 1 Filtered 4 44 36” 5HP 16,000
10’-0" 10’-0" 5’-0" 10’-4” 10’-2” 8’-4” 9'-4" 9'-10.5" 1 Filtered 2 25 30” 3HP 10,000 12’-0" 10’-0" 7’-0" 12’-4” 10’-2” 10’-4” 11'-4" 9'-10.5" 1 Filtered 2 30 30” 3HP 12,000 14’-0" 10’-0" 7’-0" 15’-0” 10’-6” 10’-8” 13'-4" 9'-10.5" 1 Filtered 2 40 30” 5HP 14,000 16’-0" 10’-0" 7’-0" 17’-0” 10’-6” 11’-8” 13'-4" 9'-10.5" 1 Filtered 2 45 36” 5HP 16,000 18’-0" 10’-0" 7’-0" 19’-0” 10’-6” 11’-8” 13'-4" 9'-10.5" 1 Filtered 3 50 36” 5HP 18,000 20’-0" 10’-0" 7’-0" 21’-0” 10’-6” 11’-8” 13'-4" 9'-10.5" 1 Filtered 4 55 42” 5HP 20,000
10’-0" 12’-0" 5’-0" 10’-4” 12’-2” 8’-4” 9'-4" 11'-10.5" 1 Filtered 2 30 30” 3HP 12,000 12’-0" 12’-0" 7’-0" 12’-4” 12’-2” 10’-4” 11'-4" 11'-10.5" 1 Filtered 2 36 30” 5HP 14,400 14’-0" 12’-0" 7’-0" 15’-0” 12’-6” 11’-8” 13'-4" 11'-10.5" 1 Filtered 2 48 36” 5HP 16,800 16’-0" 12’-0" 7’-0" 17’-0” 12’-6” 11’-8” 13'-4" 11'-10.5" 1 Filtered 2 54 42” 5HP 19,200 18’-0" 12’-0" 7’-0" 19’-0” 12’-6” 11’-8” 13'-4" 11'-10.5" 1 Filtered 3 60 42” 5HP 21,600 20’-0" 12’-0" 7’-0" 21’-0” 12’-6” 11’-8” 13'-4" 11'-10.5" 1 Filtered 4 66 42” 7.5HP 24,000
ENCLOSED INDUSTRIAL BOOTH
Industrial Auto Wood
Model Number EIB-10-07-05-00 EIB-12-07-07-00 EIB-14-07-07-00 EIB-16-07-07-00 EIB-18-07-07-00 EIB-20-07-07-00
EIB-10-08-05-00 EIB-12-08-07-00 EIB-14-08-07-00 EIB-16-08-07-00 EIB-18-08-07-00 EIB-20-08-07-00
EIB-10-10-05-00 EIB-12-10-07-00 EIB-14-10-07-00 EIB-16-10-07-00 EIB-18-10-07-00 EIB-20-10-07-00
EIB-10-12-05-00 EIB-12-12-07-00 EIB-14-12-07-00 EIB-16-12-07-00 EIB-18-12-07-00 EIB-20-12-07-00 Reference Key A B C D E
EZ EXHAUST CHAMBERS
The EZ Exhaust Chamber is designed for exhausting dust, harmful vapors and into the atmosphere. The chambers are available in a wide range of designs to meet practically any production requirement. Air replacement automatic spray operations.
for use in paint spray exhaust chambers, exhaust stack. All exhaust fans are of non-sparking construction. The motor drive and bearings are sealed from the air stream of the exhaust. Motors are provided with each unit.Optional explosion-proof motor upgrade is
Chambers are constructed from 18-gauge, prime quality, galvanized steel. Structural steel is used to add strength and rigidity to chambers supplied by others.
This exhaust bench provides a very practical method for removing other shop-related operations.
thereby reducing health hazards for shop personnel.
Industrial Auto Wood
Model Exterior Dimensions Qty. Fan Fan SCFM @Number Width Height Length Filters Diameter HP 1/2" SPIBC-04-07 4'-4" 7'-2" 2'-2" 8 18" .75HP 3,500
IBC-06-07 6'-4" 7'-2" 2'-8" 12 24" 1HP 5,250
IBC-08-07 8'-4" 7'-2" 2'-8" 16 24" 2HP 7,000
IBC-10-07 10'-4" 7'-2" 3'-2" 20 30" 2HP 8,750
IBC-12-07 12'-4" 7'-2" 3'-2" 24 30" 3HP 10,500
IBC-14-07 14'-4" 7'-2" 3'-6" 32 30" 3HP 12,250
IBC-16-07 16'-4" 7'-2" 3'-6" 36 30" 5HP 14,000
IBC-18-07 18'-4" 7'-2" 4'-6" 40 36" 5HP 15,750
IBC-20-07 20'-4" 7'-2" 4'-6" 44 36" 5HP 17,500
IBC-04-08 4'-4" 8'-2" 2'-2" 8 18" 1HP 4,000
IBC-06-08 6'-4" 8'-2" 2'-8" 12 24" 1.5HP 6,000
IBC-08-08 8'-4" 8'-2" 2'-8" 16 24" 3HP 8,000
IBC-10-08 10'-4" 8'-2" 3'-2" 20 30" 3HP 10,000
IBC-12-08 12'-4" 8'-2" 3'-2" 24 30" 3HP 12,000
IBC-14-08 14'-4" 8'-2" 3'-6" 32 30" 5HP 14,000
IBC-16-08 16'-4" 8'-2" 4'-6" 36 36" 5HP 16,000
IBC-18-08 18'-4" 8'-2" 4'-6" 40 36" 5HP 18,000
IBC-20-08 20'-4" 8'-2" 4'-6" 44 42" 5HP 20,000
IBC-04-10 4'-4" 10'-2" 2'-2" 10 18" 1.5HP 5,000
IBC-06-10 6'-4" 10'-2" 2'-8" 15 24" 2HP 7,500
IBC-08-10 8'-4" 10'-2" 3'-2" 20 30" 3HP 10,000
IBC-10-10 10'-4" 10'-2" 3'-2" 25 30" 3HP 12,500
IBC-12-10 12'-4" 10'-2" 3'-2" 30 30" 5HP 15,000
IBC-14-10 14'-4" 10'-2" 4'-6" 40 36" 5HP 17,500
IBC-16-10 16'-4" 10'-2" 4'-6" 45 42" 5HP 20,000
IBC-18-10 18'-4" 10'-2" 4'-6" 50 42" 5HP 22,500
IBC-20-10 20'-4" 10'-2" 4'-6" 55 42" 7.5HP 25,000
IBC-04-12 4'-4" 12'-2" 2'-8" 12 24" 1.5HP 6,000
IBC-06-12 6'-4" 12'-2" 2'-8" 18 24" 3HP 9,000
IBC-08-12 8'-4" 12'-2" 3'-2" 24 30" 3HP 12,000
IBC-10-12 10'-4" 12'-2" 3'-2" 30 30" 5HP 15,000
IBC-12-12 12'-4" 12'-2" 4'-2" 36 36" 5HP 18,000
IBC-14-12 14'-4" 12'-2" 4'-6" 48 42" 5HP 21,000
IBC-16-12 16'-4" 12'-2" 4'-6" 54 42" 7.5HP 24,000
IBC-18-12 18'-4" 12'-2" 4'-6" 60 42" 7.5HP 27,000
IBC-20-12 20'-4" 12'-2" 4'-6" 66 42" 10HP 30,000
Reference Key A B C
Model Exterior Dimensions CFM @ Fan Spec Filters ManometerNumber Width Height Length 1/2" SP Dia. HP Exhaust EB-12 12'-0" 3'-2" 2'-4" 5,000 18" 1.5 7 YES
EB-15 15'-0" 3'-2" 2'-4" 5,000 18" 1.5 8 YES
PLAN VIEW END VIEW SIDE ELEVATION
EZ EXHAUST CHAMBERS
Industrial Auto Wood
EZ CLASSIC CROSSDRAFT
OVERVIEW
LIGHTING FEATURES
added
Industrial Auto Wood
EZ CLASSIC CROSSDRAFT
Interior Dimensions Exterior Dimensions Access Nominal Door Opening Lights Air Flow Fan Spec. Filters Width Height Length Width Height Length Doors Width Height Qty Type Open S&G SCFM Dia. HP Int. Exh.
14’-0” 9’-0” 26’-0” 14’-6.5” 10’-0" 26’-4” 1 9’-4” 8’-10.5” 1 Filtered 9 1 12,600 30” 3HP 20 16
14’-0” 9’-0” 28’-0” 14’-6.5” 10’-0" 28’-4” 1 9’-4” 8’-10.5” 1 Filtered 9 1 12,600 30” 3HP 20 16
14’-0” 9’-0” 30’-0” 14’-6.5” 10’-0" 30’-4” 1 9’-4” 8’-10.5” 1 Filtered 9 1 12,600 30” 3HP 20 16
ModelNumber
ECC-14-09-26-N-SB
ECC-14-09-28-N-SB
ECC-14-09-30-N-SB
Reference Key A B C D E F
Alternative Configurations: Reverse Flow (RF) Drive Through (DT)Alternative Options: Pressurized (P)Standard Length Sizing is Illustrated above
Actual Working Depth is 18 inches less than interior length.
Industrial Auto Wood
EZ MODIFIED DOWNDRAFT
Industrial Auto
OVERVIEW
LIGHTING FEATURES
Wood
Interior Dimensions Exterior Dimensions Access Nominal Door Opening Lights Air Flow Fan Spec. Filters Width Height Length Width Height Length Doors Width Height Qty Type Open S&G SCFM Dia. HP Int. Exh.
14’-0” 9’-0” 26’-0” 14’-6.5” 10’-0" 26’-4” 1 9’-4” 8’-10.5” 1 Solid 9 1 12,600 30” 3HP 15 16
14’-0” 9’-0” 28’-0” 14’-6.5” 10’-0" 28’-4” 1 9’-4” 8’-10.5” 1 Solid 9 1 12,600 30” 3HP 15 16
14’-0” 9’-0” 30’-0” 14’-6.5” 10’-0" 30’-4” 1 9’-4” 8’-10.5” 1 Solid 9 1 12,600 30” 3HP 15 16
EZ MODIFIED DOWNDRAFT
ModelNumber
EMD-14-09-26-N-SB
EMD-14-09-28-N-SB
EMD-14-09-30-N-SB
Reference Key A B C D E F
Alternative Configurations: Reverse Flow (RF) Drive Through (DT) Alternative Options: Pressurized (P) Pre-Filtered (PF)Standard Length Sizing is Illustrated above
Actual Working Depth is 18 inches less than interior length.
Industrial Auto Wood
EZ SIDE DOWNDRAFT
OVERVIEWThe Col-Met EZ Side Downdraft Booth intakes fresh air from the cleaner upper levels of the shop through a filtered booth ceiling. The filtered air is drawn down and away from the product through exhaust filters at the floor level, along both sides. This provides efficient overspray control that reduces prep time and also provides a much healthier workplace environment without an expensive downdraft exhaust pit. This booth can also be purchased with a pre-filtered plenum or with a pressurized intake plenum, the booth can also be equipped with an air replacement unit and cure cycle to meet your requirements. This booth also available in either drive-through or solid back configurations.LIGHTING FEATURESBright, full booth illumination is provided by ten four-tube, 48", 32-watt, fluorescent light fixtures in the angled ceiling panels and side walls. Each is sealed behind clear, tempered safety glass. All fixtures are UL listed and approved for their intended use and placement.
prime-quality steel are precision punched for easy nut and bolt assemblyfans and motors
doors are pre-hung in a heavy gauge galvanized steel frame for easy installation.on slotted hinges to facilitate
electric components can be purchased separately when control panel is added
Industrial Auto Wood
Model Interior Dimensions Exterior Dimension Access Nominal Door Opening Lights Air Flow Fan Spec. FiltersNumber Width Height Length Width Height Length Doors Width Height Qty Type Open S&G SCFM Dia. HP Int. Exh.
ESD-14-09-26-N-SB 14’-0” 9’-0” 26’-0” 16’-4” 10’ -0" 26’-4” 1 9’-4” 8’-10.5” 1 Solid 9 1 12,740 (2) 24” 2HP 32 20
EZ SIDE DOWNDRAFT
Reference Key A B C D E F
Alternative Configurations: Drive Through (DT)Alternative Options: Pressurized (P) Pre-Filtered (PF)Standard Length Sizing is Illustrated above
Industrial Auto Wood
• EZ TO INSTALL
• EZ TO OPERATE
• EZ TO MAINTAIN
• EZ TO PRESSURIZE
EZ PIT DOWNDRAFT
OVERVIEWThe EZ Pit Downdraft Booth takes in fresh air from the cleaner upper levels of the shop, through a filtered booth ceiling. The filtered air is drawn down and away from the product through exhaust filters in the pit located in the floor. This provides efficientoverspray control that reduces prep time and also provides a much healthier workplace environment. An optional above ground basement exhaust plenum is available for installation without concrete work.This booth can be purchased with a pre-filtered plenum or with a pressurized intake plenum. It can also be equipped with an air replacement unit and cure cycle to meet your requirements. The EZ Pit Downdraft Booth is available in either drive-through or solid back configurations.LIGHTING FEATURESBright, full booth illumination is provided by ten four-tube, 48 , 32-watt fluorescent light fixtures in the angled ceiling panels and side walls. Each is sealed behind clear tempered safety glass. All fixtures are UL listed and approved for their intended use and placement.
prime-quality steel are precision punched for easy nut and bolt assemblyfans and motors
Windowed personnel access doors are pre-hung in a heavy gauge galvanized steel frame for easy installation.to facilitate installation on
electric components can be purchased separately when control panel is added
BOOTH SHOWN WITH OPTIONAL ABOVE GROUND BASEMENT
Industrial Auto Wood
Interior Dimensions Exterior Dimensions Access Nominal Door Opening Illumination Air Flow Fan Spec. Filters Width Height Length Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh.
14'-0" 9'-0" 26'-0" 14'-10.5" 10'-0" 26'-4" 1 9'-4" 8'-10.5" 1 Solid 1 9 10 12,740 30" 3 HP 32 24
ModelNumber EPD-14-09-26-N-SB
EZ PIT DOWNDRAFT
Reference Key A B C D E F
Alternative Configurations: Drive Through (DT)Alternative Options: Pressurized (P) Pre-Filtered (PF)Standard Length Sizing is Illustrated above
Industrial Auto Wood
EZ PAINT MIXING ROOM
OVERVIEWLIGHTING FEATURES
Interior Dimensions Exterior Dimensions Access Lights Air Flow Fan Spec. Filters
Width Height Length Width Height Length Doors Open S&G SCFM Dia. HP Int. Exh.
8'-0" 8'-0" 8'-0" 8'-4" 8'-2" 10'-6" 1 with Window 1 0 1450 12" ¾ HP 4 2
8'-0" 8'-0" 10'-0" 8'-4" 8'-2" 12'-6" 1 with Window 1 1 1450 12" ¾ HP 4 2
8'-0" 8'-0" 12'-0" 8'-4" 8'-2" 14'-6" 1 with Window 1 1 1450 12" ¾ HP 4 2
8'-0" 8'-0" 15'-0" 8'-4" 8'-2" 17'-6" 1 with Window 2 1 1450 12" ¾ HP 4 2
10'-0" 8'-0" 15'-0" 10'-4" 8'-2" 17'-6" 1 with Window 2 1 1450 12" ¾ HP 4 2
PMR-08-08-08
PMR-08-08-10
PMR-08-08-12
PMR-08-08-15
PMR-10-08-15
Model
Number
EZ PAINT MIXING ROOM
Ref. Key A B C D
CONSTRUCTION FEATURES AND QUALITY STANDARDS
EZ LIMITED FINISHING PREP STATION
OVERVIEW
LIGHTING FEATURES
BOOTH SHOWN WITH OPTIONAL CURTAINS
Industrial Auto Wood
Interior Dimensions Exterior Dimensions Nominal Clear Entry Lights Air Flow Fan Spec. Filters
Width Height Length Width Height Length Width Height Open SCFM Dia. HP Int. Ext.
14’-0” 10’-0” 24’-0” 14’-4” 12’-2” 26’-6” 14’-0” 10’-0” 8 5,000 (2)18” 1.5 12 12EPS-14-10-24-P-SB
Model
Number
EZ LIMITED FINISHING PREP STATION
Reference Key A B C
Industrial Auto Wood
500° POWDER CURE BATCH OVEN
Technical Data
Construction
Industrial Powder
COL-MET STANDARD CONTROLS COL-MET SMART TOUCH CONTROLS
Model Inside (Ft.-0”) Single Entry Outside Double Entry Outside Recirculating Fan Exhaust Fan Burner Gas
Number W H D W H D W H D SCFM HP SCFM HP BTU HP AREA Train
BO-05-06-05-SE 5'-0" 6'-0" 5'-0" 7’-4” 7’-4” 10’-2” 7’-4” 11’-0” 5’-10” 1,500 1.5 500 1 500 0.33 150 1” NPTBO-05-06-06-SE 5'-0 " 6'-0" 6'-0" 7’-4” 7’-4” 11’-2” 7’-4” 11’-0” 6’-10” 1,800 1.5 500 1 500 0.33 180 1” NPTBO-05-06-07-SE 5'-0 " 6'-0" 7'-0" 7’-4” 7’-4” 12’-2” 7’-4” 11’-0” 7’-10” 2,100 2 500 1 500 0.33 210 1” NPTBO-05-06-08-SE 5'-0 " 6'-0" 8'-0" 7’-4” 7’-4” 13’-2” 7’-4” 11’-0” 8’-10” 2,400 2 500 1 500 0.33 240 1” NPTBO-05-06-10-SE 5'-0 " 6'-0" 10'-0" 7’-4” 7’-4” 14’-2” 7’-4” 11’-0” 10’-10” 3,000 3 500 1 500 0.33 300 1” NPTBO-05-06-12-SE 5'-0 " 6'-0" 12'-0" 7’-4” 7’-4” 16’-2” 7’-4” 11’-0” 12’-10” 3,600 5 500 1 500 0.33 360 1” NPTBO-06-06-06-SE 6'-0" 6'-0" 6'-0" 8’-4” 7’-4” 11’-2” 8’-4” 11’-0” 6’-10” 2,160 2 500 1 500 0.33 216 1” NPTBO-06-06-08-SE 6'-0" 6'-0" 8'-0" 8’-4” 7’-4” 13’-2” 8’-4” 11’-0” 8’-10” 2,880 3 500 1 500 0.33 288 1” NPTBO-06-06-10-SE 6'-0" 6'-0" 10'-0" 8’-4” 7’-4” 15’-2” 8’-4” 11’-0” 10’-10” 3,600 5 500 1 500 0.33 360 1” NPTBO-06-06-12-SE 6'-0" 6'-0" 12'-0" 8’-4” 7’-4” 17’-2” 8’-4” 11’-0” 12’-10” 4,320 5 500 1 500 0.33 432 1” NPTBO-06-06-14-SE 6'-0" 6'-0" 14'-0" 8’-4” 7’-4” 19’-2” 8’-4” 11’-6” 14’-10” 5,040 5 500 1 500 0.33 504 1” NPTBO-06-06-16-SE 6'-0" 6'-0" 16'-0" 8’-4” 7’-4” 21’-2” 8’-4” 11’-6” 16’-10” 5,760 5 500 1 1,000 0.33 576 1” NPTBO-06-07-06-SE 6'-0" 7'-0" 6'-0" 8’-4” 8’-4” 11’-2” 8’-4” 12’-0” 6’-10” 2,520 5 500 1 500 0.33 252 1” NPTBO-06-07-08-SE 6'-0" 7'-0" 8'-0" 8’-4” 8’-4” 13’-2” 8’-4” 12’-0” 8’-10” 3,360 5 500 1 500 0.33 336 1” NPTBO-06-07-10-SE 6'-0" 7'-0" 10'-0" 8’-4” 8’-4” 14’-2” 8’-4” 12’-6” 10’-10” 4,200 5 500 1 500 0.33 420 1” NPTBO-06-07-12-SE 6'-0" 7'-0" 12'-0" 8’-4” 8’-4” 16’-2” 8’-4” 12’-6” 12’-10” 5,040 5 500 1 500 0.33 504 1” NPTBO-06-07-14-SE 6'-0" 7'-0" 14'-0" 8’-4” 8’-4” 18’-2” 8’-4” 12’-6” 14’-10” 5,880 5 500 1 1,000 0.33 588 1” NPTBO-06-07-16-SE 6'-0" 7'-0" 16'-0" 8’-4” 9’-4” 20’-4” 8’-4” 12’-6” 16’-10” 6,720 5 500 1 1,000 0.33 672 1” NPTBO-06-08-06-SE 6'-0" 8 '-0" 6'-0" 8’-4” 9’-4” 11’-2” 8’-4” 12’-6” 6’-10” 2,880 3 500 1 500 0.33 288 1” NPTBO-06-08-08-SE 6'-0" 8'-0" 8'-0" 8’-4” 9’-4” 13’-2” 8’-4” 12’-6” 8’-10” 3,840 3 500 1 500 0.33 384 1” NPTBO-06-08-10-SE 6'-0" 8'-0" 10'-0" 8’-4” 9’-4” 15’-2” 8’-4” 13’-6” 10’-10" 4,800 5 500 1 500 0.33 480 1” NPTBO-06-08-12-SE 6'-0" 8'-0" 12'-0" 8’-4” 9’-4” 17’-2” 8’-4” 13’-6” 12’-10” 5,760 5 500 1 500 0.33 576 1” NPTBO-06-08-14-SE 6'-0" 8'-0" 14'-0" 8’-4” 9’-4” 19’-4” 8’-4” 13’-6” 14’-10” 6,720 5 500 1 1,000 0.33 672 1” NPTBO-06-08-16-SE 6'-0" 8 '-0" 16'-0" 8’-4” 9’-4” 21’-4” 8’-4” 13’-6” 16’-10” 7,680 7.5 500 1 1,000 0.33 768 1” NPTBO-07-07-07-SE 7'-0" 7'-0" 7'-0" 9’-4” 8’-4” 12’-8” 8’-4” 12’-0” 7’-10” 3,430 5 500 1 500 0.33 343 1” NPTBO-07-07-08-SE 7'-0" 7'-0" 8'-0" 9’-4” 8’-4” 13’-8” 8’-4” 12’-0” 8’-10” 3,920 3 500 1 500 0.33 392 1” NPTBO-07-07-10-SE 7'-0" 7'-0" 10'-0" 9’-4” 8’-4” 16’-2” 8’-4” 12’-6” 10’-10” 4,900 5 500 1 500 0.33 490 1” NPTBO-07-07-12-SE 7'-0" 7'-0" 12'-0" 9’-4” 8’-4” 18’-2” 8’-4” 12’-6” 12’-10” 5,880 5 500 1 1,000 0.33 588 1” NPTBO-07-07-14-SE 7'-0" 7'-0" 14'-0" 9’-4” 8’-4” 20’-2” 8’-4” 12’-6” 14’-10” 6,860 7.5 500 1 1,000 0.33 686 1” NPTBO-07-07-16-SE 7'-0" 7'-0" 16'-0" 9’-4” 8’-4” 22’-8” 8’-4” 12’-8” 16’-10” 7,840 7.5 750 1 1,000 0.33 784 1” NPTBO-08-08-08-SE 8'-0" 8'-0" 8'-0" 10’-10” 9’-4” 14’-8” 10’-10” 13’-10” 8’-10” 5,120 5 500 1 500 0.33 512 1” NPTBO-08-08-10-SE 8'-0" 8'-0" 10'-0" 10’-10” 9’-4” 16’-8” 10’-10” 13’-10” 10’-10” 6,400 5 500 1 1,000 0.33 640 1” NPTBO-08-08-12-SE 8'-0" 8'-0" 12'-0" 10’-10” 9’-4” 18’-10” 10’-10” 14’-0” 12’-10” 7,680 7.5 500 1 1,000 0.33 768 1” NPTBO-08-08-14-SE 8'-0" 8'-0" 14'-0" 10’-10” 9’-4” 20’-10” 10’-10” 14’-0” 14’-10” 8,960 7.5 750 1 1,000 0.33 896 1” NPTBO-08-08-16-SE 8'-0" 8 '-0" 16'-0" 10’-10” 9’-4” 21’-10” 10’-10” 14’-0” 16’-10” 10,240 10 1,000 1 1,000 0.33 1,024 1” NPTBO-08-08-20-SE 8'-0" 8'-0" 20'-0" 10’-10” 9’-4” 27’-8” 10’-10” 14’-6” 20’-10” 12,800 10 1,350 1 1,500 0.33 1,280 1.5” NPTBO-08-10-08-SE 8'-0" 10'-0" 8'-0" 10’-10” 11’-4” 14’-4” 10’-10” 15’-10” 8’-10” 6,400 5 500 1 1,000 0.33 640 1” NPTBO-08-10-10-SE 8'-0" 10'-0" 10'-0" 10’-10” 11’-4” 16’-4” 10’-10” 15’-10” 10’-10” 8,000 7.5 750 1 1,000 0.33 800 1” NPTBO-08-10-12-SE 8'-0" 10'-0" 12'-0" 10’-10” 11’-4” 18’-4” 10’-10” 15’-10” 12’-10” 9,600 10 1,000 1 1,000 0.33 960 1” NPTBO-08-10-14-SE 8'-0" 10'-0" 14'-0" 10’-10” 11’-4” 16’-4” 10’-10” 16’-0” 14’-10” 11,200 10 1,000 1 1,500 0.33 1,120 1.5” NPTBO-08-10-16-SE 8'-0" 10'-0" 16'-0" 10’-10” 11’-4” 18’-10” 10’-10” 17’-2” 16’-10” 12,800 10 1,000 1 1,500 0.33 1,280 1.5” NPTBO-10-10-10-SE 10'-0" 10'-0" 10'-0" 12’-10” 11’-4” 17’-0” 10’-10” 17’-2” 10’-10” 10,000 10 1,000 1 1,000 0.33 1,000 1” NPTBO-10-10-12-SE 10'-0" 10 -0" 12'-0" 12’-10” 11’-4” 19’-6” 10’-10” 17’-2” 12’-10” 12,000 10 1,000 1 1,500 0.33 1,200 1.5” NPTBO-10-10-14-SE 10'-0" 10-0" 14'-0" 12’-10” 11’-4” 21’-6” 10’-10” 17’-2” 14’-10” 14,000 10 1,350 1 1,500 0.33 1,400 1.5” NPT
Alternative Configurations: Double Entry (DE)
500° POWDER CURE BATCH OVEN
Industrial Powder
BATCH POWDER BOOTH
Industrial
The Batch Powder Booth makes efficient use of shop space and is designed for batch powder coating with no provisions for powder reclamation.Air is drawn in through the open front of the spray booth, passes through the booth’s working area into the filtered exhaust plenum. The air is filtered in three stages and discharged back into the room. One set of filters will be provided with each booth.
electric components can be purchased separately
OVERVIEW
POWDER EXHAUST FILTER PROVING ASSEMBLY
are precision punched for easy nut and bolt assembly
Powder
BATCH POWDER BOOTH
Interior Dimensions Exterior Dimensions Total Fan Specs. Lights
Width Height Length Width Height Length CFM Qty. Dia. HP S&G
4'-0" 7'-0" 5'-0" 4'-4" 12'-0" 8'-4" 2,800 1 18" 1.5 1 6'-0" 7’-0" 5'-0" 6'-4" 12'-0" 8'-6" 4,200 1 24" 2 1 8'-0" 7'-0" 5'-0" 8'-4" 12'-0" 8'-6" 5,600 1 24" 3 1 10'-0" 7'-0" 5'-0" 10'-4" 12'-0" 9'-0" 7,000 1 30" 3 2 12'-0" 7'-0" 7'-0" 12'-4" 13'-0" 11'-0" 8,400 1 30" 5 2 14'-0" 7'-0" 7'-0" 15'-0" 13'-0" 11'-2" 9,800 1 30" 5 2 16'-0" 7'-0" 7'-0" 17'-0" 12'-0" 10'-8" 11,200 2 (5600CFM) 24" 3 2 4'-0" 8'-0" 5'-0" 4'-4" 13'-0" 8'-4" 3,200 1 18" 2 1 6'-0" 8'-0" 5'-0" 6'-4" 13'-0" 8'-6" 4,800 1 24" 2 1 8'-0" 8'-0" 5'-0" 8'-4" 13'-0" 8'-6" 6,400 1 24" 3 1 10'-0" 8'-0" 5'-0" 10'-2" 14'-0" 9'-0" 8,000 1 30" 5 2 12'-0" 8'-0" 7'-0" 12'-4" 14'-0" 11'-0" 9,600 1 30" 5 2 14'-0" 8'-0" 7'-0" 15'-0" 13'-0" 10'-8" 11,200 2 (5600CFM) 24" 3 2 16'-0" 8'-0" 7'-0" 17'-0" 13'-0" 10'-8" 12,800 2 (6400CFM) 24" 3 2 4'-0" 10'-0" 5'-0" 4'-4" 15'-0" 8'-6" 4,000 1 24" 2 1 6'-0" 10'-0" 5'-0" 6'-4" 15'-0" 8'-6" 6,000 1 24" 3 1 8'-0" 10'-0" 5'-0" 8'-4" 16'-0" 9'-8" 8,000 1 30" 5 1 10'-0" 10'-0" 5'-0" 10'-4" 15'-0" 8'-6" 10,000 2 (5000CFM) 24" 3 2 12'-8" 10'-0" 7'-0" 12'-4" 15'-0" 10'-6" 12,000 2 (6000CFM) 24" 3 2 14'-0" 10'-0" 7'-0" 15'-0" 15'-0" 11'-2" 14,000 2 (7000CFM) 30" 3 2 16'-0" 10'-0" 7'-0" 17'-0" 16'-0" 11'-2" 16,000 2 (8000CFM) 30" 5 2
Reference Key A B C D E F
PB-04-07-05PB-06-07-05PB-08-07-05PB-10-07-05PB-12-07-07PB-14-07-07PB-16-07-07PB-04-08-05PB-06-08-05PB-08-08-05PB-10-08-07PB-12-08-07PB-14-08-07PB-16-08-07PB-04-10-05PB-06-10-05PB-08-10-05PB-10-10-05PB-12-10-07PB-14-10-07PB-16-10-07
ModelNumber
Industrial Powder
CARTRIDGE BATCH POWDER BOOTHWITH NON-ROLLAWAY CASTER BASE
Industrial
PANELSPanels are fabricated from 18-gauge prime quality galvanized steel, flanged and precision punched on 6 centers for maximum rigidity. Panels are fastened together with 5/16 inch bolts with self locking nuts and are to be sealed with the provided caulk following assembly.ILLUMINATIONLighting is provided by Class I Division II, 48 long, fluorescent, 32-watt, T-8 type fixtures (four-tube), mounted behind safety glass; appropriately sealed from the interior of the spray booth. All fixtures are UL listed and approved for their intended use and placement.PURGE CONTROL This feature assures the safe operation of the coatings enclosure, by maintaining the airflow at design levels. During operation overspray powder accumulates on the cartridgefilters. As the cartridge filters load, airflow decreases and negative pressure rises within the air handler. A timer activates a system of air purging valves that clear the cartridge filters of accumulated powder to ensure maximum filter life.CONTROL EQUIPMENT
COLLECTOR MODULE
POWDER COLLECTOR STYLE BOOTH
CARTRIDGE COLLECTOR
Powder
CARTRIDGE COLLECTORS
POWDER BOOTHS
Model
Interior Dimensions Exterior Dimensions Total Modules Cartridge Final Fan Spec. Lights Number Width Height Length Width Height Length CFM Modules Filters Filters Qty. HP S & G
RPC-4000 N/A N/A N/A 4’-8” (w/CP 5’-10”) 8’-8” (w/MFD 9’-4”) 4’-4” (w/ Motor 6’-1”) 4000 @3” SP 1 4 4 1 5 HP N/A
RPC-5000 N/A N/A N/A 4’-8” (w/CP 5’-10”) 8’-8” (w/MFD 9’-4”) 4’-4” (w/ Motor 6’-1”) 5000 @3” SP 1 5 4 1 7.5 HP N/A
RPC-6000 N/A N/A N/A 6’-0” (w/CP 7’-2”) 8’-8” (w/MFD 9’-4”) 5’-3” (w/ Motor 6’-2”) 6000 @3” SP 1 6 6 1 7.5 HP N/A
RPC-7000 N/A N/A N/A 6’-0” (w/CP 7’-2”) 8’-8” (w/MFD 9’-4”) 5’-3” (w/ Motor 6’-2”) 7000 @3” SP 1 7 6 1 10 HP N/A
RPC-8000 N/A N/A N/A 6’-0” (w/CP 7’-2”) 8’-8” (w/MFD 9’-4”) 5’-3” (w/ Motor 6’-2”) 8000 @3” SP 1 7 6 1 10 HP N/A
Model Interior Dimensions Exterior Dimensions Total Modules Cartridge Final Fan Spec. Lights Number Width Height Length Width Height Length CFM Filters Filters Qty. HP S & G
RPB -08-07-7.5 7’-0” 8’-0” 7’-6” 8’-4” 9’-4” 13’-8” 6000 @3” SP 1 (6,000 CFM) 6 6 1 7.5 HP 1
RPB-08-08-7.5 8’-0” 8’-0” 7’-6” 8’-4” 9’-4” 13’-8” 6000 @3” SP 1 (6,000 CFM) 6 6 1 7.5 HP 1
RPB-08-10-7.5 8’-0” 10’-0” 7’-6” 8’-4” 10’-2” 13’-8” 8000 @3” SP 1 (8,000 CFM) 7 6 1 10 HP 1
RPB-10-07-7.5 10’-0” 7’-0” 7’-6” 10’-4” 9’-4” 13’-8” 7000 @3” SP 1 (7,000 CFM) 7 6 1 10 HP 2
RPB-10-08-7.5A 10’-0” 8’-0” 7’-6” 10’-4” 9’-4” 13’-8” 8000 @3” SP 1 (8,000 CFM) 7 6 1 10 HP 2
RPB-10-08-7.5B 10’-0” 8’-0” 7’-6” 10’-4” 9’-4” 13’-7” 8000 @3” SP 2 (4,000 CFM) 7 8 2 5 HP 2
RPB-10-10-7.5 10’-0” 10’-0” 7’-6” 10’-4” 10’-2” 13’-7” 10000 @3” SP 2 (5,000 CFM) 9 8 2 7.5 HP 2
RPB-12-07-7.5A 12’-0” 7’-0” 7’-6” 12’-4” 9’-4” 13’-8” 8000 @3” SP 1 (8,000 CFM) 7 6 1 10 HP 2
RPB-12-07-7.5B 12’-0” 7’-0” 7’-6” 12’-4” 9’-4” 13’-7” 8000 @3” SP 2 (4,000 CFM) 7 8 2 5 HP 2
RPB-12-08-7.5 12’-0” 8’-0” 7’-6” 12’-4” 9’-4” 13’-7” 10000 @3” SP 2 (5,000 CFM) 9 8 2 7.5 HP 2
RPB-12-10-7.5 12’-0” 10’-0” 7’-6” 12’-4” 10’-2” 13’-7” 12000 @3” SP 2 (6,000 CFM) 9 12 2 7.5 HP 2
Reference Key A B C D E F
CARTRIDGE BATCH POWDER BOOTHWITH NON-ROLLAWAY CASTER BASE
Industrial Powder
EZ PASS THRU POWDER BOOTH
Parts enter the booth through the conveyor openings, then pass the coating operator stations to receive the coating. The powder overspray is entrained within the air stream moving to the collector module, where the cartridge filters will remove the particulate. The containment air is drawn through the air handler’s primary and final filter system before being discharged back into the room. Coated parts exit the booth for conveyance to the cure oven. CONTROL EQUIPMENT
ILLUMINATION " long, fluorescent, listed and approved for their intended use and placement.
™ roof panels may be substituted for the light fixtures. PURGE CONTROLThis feature assures the safe operation of the coatings enclosure, powder accumulates on the cartridge filters. The term for this is valves that clear the cartridge filters of accumulated powder as needed.SAFETY EQUIPMENT
CONSTRUCTION FEATURES AND QUALITY STANDARDSBooths
SHOWN WITH STAINLESS STEEL OPTION & LEXAN ROOF OPTION
POWDER BOOTH WITH COLLECTOR MODULE
Industrial Powder
COLLECTOR MODULE
filter section does not have to be cleaned between color change outs.™" " long
™ " " "
AVAILABLE OPTIONS
four regulator air manifolds
Reference Key A B C D E
Model Cabin Dimensions I.D. Part Opening Operator Access Total
Number Width Height Length Width Height Auto Manual CFM
EPB-05-08-14 5’-0” 8’-0” 14’-0” 3’-0” 6’-0” 2 2 7,000 @ 4.5” SP
EPB-06-08-14 6’-0” 8’-0” 14’-0” 4’-0” 6’-0” 2 2 8,000 @ 4.5” SP
EPB-07-08-14 7’-0” 8’-0” 14’-0” 5’-0” 6’-0” 2 2 9,000 @ 4.5” SP
EZ PASS THRU POWDER BOOTH
Industrial Powder
LAB POWDER BOOTH
PANELS Panels are fabricated from18-gauge prime quality stainless steel, flanged and precision punched on 6 centers for maximum rigidity. Panels are fastened together with 5/16 nuts and bolts, and are to be sealed with the pro-vided caulk following assembly.BASE ASSEMBLYThe rollaway base assembly cabinet and floor support is fabricated with 3 channel steel and formed 10-gauge mild steel (welded construc-tion). The finish will be white powder coating.
friendlywork area
LAB POWDER BOOTHWITH ROLLAWAY CASTER BASE
ILLUMINATION long, fluorescent, 32-watt, T-8 type, four-tube fixture, mounted behind safety glass; appropriately sealed for their intended use and placement. PLC BASED PURGE CONTROLThis feature assures the safe operation of the coatings enclosure,
activates a system of air purging valves that clear the cartridge filters of accumulated powder to ensure maximum life.
CONSTRUCTION FEATURES / ADVANTAGES CONTROL EQUIPMENT
OPTIONAL EQUIPMENT
Industrial Powder
LAB POWDER BOOTH
Industrial Powder
LIGHT DUTY CROSSDRAFT
OVERVIEW
LIGHTING FEATURES
Industrial Truck Wood
Model Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Fan Spec. FiltersNumber Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh
LDC-16-16-26-N-SB 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 14 15 25,600 42 7.5 48 48
LDC-16-16-28-N-SB 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 14 15 25,600 42 7.5 48 48
LDC-16-16-30-N-SB 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 17 18 25,600 42 7.5 48 48
LDC-16-16-32-N-SB 16'-0" 16'-0" 32'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 17 18 25,600 42 7.5 48 48
LDC-16-16-34-N-SB 16'-0" 16'-0" 34'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 19 20 25,600 42 7.5 48 48
LDC-16-16-44-N-SB 16'-0" 16'-0" 44'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Filtered 2 26 28 25,600 42 7.5 48 48
LDC-16-16-54-N-SB 16'-0" 16'-0" 54'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Filtered 3 31 34 25,600 42 7.5 48 48
LDC-16-16-64-N-SB 16'-0" 16'-0" 64'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Filtered 4 38 42 25,600 42 7.5 48 48
Sizing Option Ranges: 14-20* 12-20* ^
Reference Key A B C D E
Alternative Configurations: Reverse Flow (RF) Drive Through (DT)Alternative Options: Pressurized (P)*Standard Sizing of Width and Height are in Increaments of 2(ft)^Standard Length Sizing is Illustrated above
LIGHT DUTY CROSSDRAFT
Industrial Truck Wood
LIGHT DUTY MODIFIED DOWNDRAFT
OVERVIEW
LIGHTING FEATURES
Industrial Truck Wood
Model Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Fan Spec. FiltersNumber Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh
LDM-16-16-26-N-SB 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 25,600 42 7.5 42 48
LDM-16-16-28-N-SB 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 25,600 42 7.5 42 48
LDM-16-16-30-N-SB 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 25,600 42 7.5 42 48
LDM-16-16-32-N-SB 16'-0" 16'-0" 32'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 25,600 42 7.5 42 48
LDM-16-16-34-N-SB 16'-0" 16'-0" 34'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 19 20 25,600 42 7.5 42 48
LDM-16-16-44-N-SB 16'-0" 16'-0" 44'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 2 26 28 25,600 42 7.5 42 48
LDM-16-16-54-N-SB 16'-0" 16'-0" 54'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 3 31 34 25,600 42 7.5 42 48
LDM-16-16-64-N-SB 16'-0" 16'-0" 64'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid 4 38 42 25,600 42 7.5 42 48
Sizing Option Ranges: 14-20* 12-20* ^
Reference Key A B C D E
Alternative Configurations: Reverse Flow (RF) Drive Through (DT)Alternative Options: Pre-Filtered (PF) Pressurized (P)*Standard Sizing of Width and Height are in Increaments of 2(ft)^Standard Length Sizing is Illustrated above
LIGHT DUTY MODIFIED DOWNDRAFT
Industrial Truck Wood
LIGHT DUTY SIDE DOWNDRAFT
OVERVIEWThe Light Duty Side Downdraft Booth intakes fresh air from the cleaner upper levels of the shop through a filtered booth ceiling.The filtered air is drawn down and away from the product through exhaust filters at the floor level, along both sides. This provides efficient overspray control that reduces prep time and also provides a much healthier workplace environment without an expensive downdraft exhaust pit. This booth can also be purchased with a pre-filtered plenum or with a pressurized intake plenum. The booth can also be equipped with an air replacement unit and cure cycle to meet your requirements. The Light Duty Side Downdraft Booth is available in either drive-through or solid back configurations.LIGHTING FEATURESBright, full booth illumination is provided by four-tube, 48", 32-watt, fluorescent light fixtures in the angled ceiling panels and side walls. All fixtures are UL listed and approved for their intended use and placement.
10 gauge, galvanized steelAll panels and support members are precision punched for easy nut and bolt assembly5/16” bolt with self locking nuts for fastening panels every 6"fans and ODP motors
doors are pre-hung in a heavy gauge galvanized steel frame for easy installation.slotted hinges to facilitate
other electric components can be purchased separatelyPanel with VFD
Industrial Truck Wood
Model Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Fan Spec. FiltersNumber Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh
LDS-16-16-26-N-SB 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 20,800 (2)30 (2)3 38 30
LDS-16-16-28-N-SB 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 22,400 (2)30 (2)5 40 32
LDS-16-16-30-N-SB 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 24,000 (2)30 (2)5 44 36
LDS-16-16-40-N-SB 16'-0" 16'-0" 40'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 2 22 24 32,000 (4)24 (4)3 58 46
LDS-16-16-50-N-SB 16'-0" 16'-0" 50'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 3 27 30 40,000 (4)30 (4)3 72 58
LDS-16-16-60-N-SB 16'-0" 16'-0" 60'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid 4 34 36 48,000 (4)30 (4)5 88 70
Sizing Option Ranges: 14-20* 12-20* ^
Reference Key A B C D E
Alternative Configurations: Drive Through (DT)Alternative Options: Pre-Filtered (PF) Pressurized (P)*Standard Sizing of Width and Height are in Increaments of 2(ft)^Standard Length Sizing is Illustrated above
LIGHT DUTY SIDE DOWNDRAFT
Industrial Truck Wood
LIGHT DUTY DOWNDRAFT
OVERVIEWThe Light Duty Downdraft Booth takes in fresh air from the cleaner upper levels of the shop, through a filtered booth ceiling. The filtered air is drawn down and away from the product through exhaust filters in the pit located in the floor. This provides efficientoverspray control that reduces prep time and also provides a much healthier workplace environment. This booth can be purchased with a pre-filtered plenum or with a pressurized intake plenum. It can also be equipped with an air replacement unit and cure cycle to meet your requirements. The Light Duty Downdraft Booth is available in either drive-through or solid back configurations.LIGHTING FEATURES
10 gauge, galvanized steelAll panels and support members are precision punched for easy nut and bolt assembly5/16” bolt with self locking nuts for fastening panels every 6"fans and motors
doors are pre-hung in a heavy gauge galvanized steel frame for easy installation.on slotted hinges to facilitate
other electric components can be purchased separately
Industrial Truck Wood
Model Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Fan Spec. FiltersNumber Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh
LDD-16-16-26-N-SB 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 20,800 42 7.5 38 26
LDD-16-16-28-N-SB 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 22,400 42 10 40 28
LDD-16-16-30-N-SB 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 24,000 42 10 44 30
LDD-16-16-40-N-SB 16'-0" 16'-0" 40'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 2 22 24 32,000 (2)42 (2)7.5 58 40
LDD-16-16-50-N-SB 16'-0" 16'-0" 50'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 3 27 30 40,000 (2)42 (2)7.5 72 50
LDD-16-16-60-N-SB 16'-0" 16'-0" 60'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid 4 32 36 48,000 (2)42 (2)10 88 60
Sizing Option Ranges: 14-20* 12-20* ^
Reference Key A B C D E
Alternative Configurations: Drive Through (DT)Alternative Options: Pre-Filtered (PF) Pressurized (P)*Standard Sizing of Width and Height are in Increaments of 2(ft)^Standard Length Sizing is Illustrated above
LIGHT DUTY DOWNDRAFT
Industrial Truck Wood
HEAVY DUTY CROSSDRAFT
OVERVIEW
LIGHTING FEATURES
heavy gauge galvanized steel
Industrial Truck Wood
HEAVY DUTY CROSSDRAFT
Model Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Fan Spec. FiltersNumber Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh
HDC-16-16-26-N-SB 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 14 15 25,600 42 7.5 48 48
HDC-16-16-28-N-SB 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 14 15 25,600 42 7.5 48 48
HDC-16-16-30-N-SB 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 17 18 25,600 42 7.5 48 48
HDC-16-16-32-N-SB 16'-0" 16'-0" 32'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 17 18 25,600 42 7.5 48 48
HDC-16-16-34-N-SB 16'-0" 16'-0" 34'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Filtered 1 19 20 25,600 42 7.5 48 48
HDC-16-16-44-N-SB 16'-0" 16'-0" 44'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Filtered 2 26 28 25,600 42 7.5 48 48
HDC-16-16-54-N-SB 16'-0" 16'-0" 54'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Filtered 3 31 34 25,600 42 7.5 48 48
HDC-16-16-64-N-SB 16'-0" 16'-0" 64'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Filtered 4 38 42 25,600 42 7.5 48 48
Sizing Option Ranges: 14-20* 12-20* ^
Reference Key A B C D E
Alternative Configurations: Reverse Flow (RF) Drive Through (DT)Alternative Options: Pressurized (P)*Standard Sizing of Width and Height are in Increaments of 2(ft)^Standard Length Sizing is Illustrated above
Industrial Truck Wood
HEAVY DUTY MODIFIED DOWNDRAFT
OVERVIEWThe Heavy Duty Modified Downdraft Booth intakes fresh air from the cleaner upper levels of the shop through a filter bank locatedin the booth ceiling near the product doors. The filtered air is drawn down through the booth to an exhaust filter system at the other end, and is optionally equipped with a pre-filter plenum for additional intake air filtration. The basic modified downdraft design allows for easy pressurization with the addition of an intake plenum with fan or a heated air make up unit.LIGHTING FEATURESBright, full booth illumination is provided by four-tube, 48 , 32-watt, fluorescent light fixtures in the angled ceiling panels andside walls. All fixtures are UL listed and approved for their intended use and placement.
W6x9 beam steelAll panels and support members are precision punched for easy nut and bolt assembly5/16” bolt with self locking nuts for fastening panels every 6" fans and motors
doors are pre-hung in a heavy gauge galvanized steel frame for easy installation.slotted hinges to facilitate
other electric components can be purchased separatelyPanel with VFD
Industrial Truck Wood
HEAVY DUTY MODIFIED DOWNDRAFT
Model Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Fan Spec. FiltersNumber Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh
HDM-16-16-26-N-SB 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 25,600 42 7.5 42 48
HDM-16-16-28-N-SB 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 25,600 42 7.5 42 48
HDM-16-16-30-N-SB 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 25,600 42 7.5 42 48
HDM-16-16-32-N-SB 16'-0" 16'-0" 32'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 25,600 42 7.5 42 48
HDM-16-16-34-N-SB 16'-0" 16'-0" 34'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 19 20 25,600 42 7.5 42 48
HDM-16-16-44-N-SB 16'-0" 16'-0" 44'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 2 26 28 25,600 42 7.5 42 48
HDM-16-16-54-N-SB 16'-0" 16'-0" 54'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 3 31 34 25,600 42 7.5 42 48
HDM-16-16-64-N-SB 16'-0" 16'-0" 64'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid 4 38 42 25,600 42 7.5 42 48
Sizing Option Ranges: 14-20* 12-20* ^
Reference Key A B C D E
Alternative Configurations: Reverse Flow (RF) Drive Through (DT)Alternative Options: Pre-Filtered (PF) Pressurized (P)*Standard Sizing of Width and Height are in Increaments of 2(ft)^Standard Length Sizing is Illustrated above
Industrial Truck Wood
HEAVY DUTY SIDE DOWNDRAFT
OVERVIEW The Heavy Duty Side Downdraft Booth intakes fresh air from the cleaner upper levels of the shop through a filtered booth ceiling. The filtered air is drawn down and away from the product through exhaust filters at the floor level, along both sides. This provides efficient overspray control that reduces prep time and also provides a much healthier workplace environment without an expensive downdraft exhaust pit. This booth can also be purchased with a pre-filtered plenum or with a pressurized intake plenum. The booth can also be equipped with an air replacement unit and cure cycle to meet your requirements. The Heavy Duty Side Downdraft Booth is available in either drive-through or solid back configurations.LIGHTING FEATURESBright, full booth illumination is provided by four-tube, 48", 32-watt, fluorescent light fixtures in the angled ceiling panels and side walls. All fixtures are UL listed and approved for their intended use and placement.
W6x9 beam steelAll panels and support members are precision punched for easy nut and bolt assembly5/16” bolt with self locking nuts for fastening panels every 6"fans and motors
doors are pre-hung in a heavy gauge galvanized steel frame for easy installation.on slotted hinges to facilitate
other electric components can be purchased separatelyPanel with VFD
Industrial Truck Wood
HEAVY DUTY SIDE DOWNDRAFT
Model Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Fan Spec. FiltersNumber Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh
HDS-16-16-26-N-SB 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 20,800 (2)30 (2)3 38 30
HDS-16-16-28-N-SB 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 22,400 (2)30 (2)5 40 32
HDS-16-16-30-N-SB 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 24,000 (2)30 (2)5 44 36
HDS-16-16-40-N-SB 16'-0" 16'-0" 40'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 2 22 24 32,000 (4)24 (4)3 58 46
HDS-16-16-50-N-SB 16'-0" 16'-0" 50'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 3 27 30 40,000 (4)30 (4)3 72 58
HDS-16-16-60-N-SB 16'-0" 16'-0" 60'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid 4 34 36 48,000 (4)30 (4)5 88 70
Sizing Option Ranges: 14-20* 12-20* ^
Reference Key A B C D E
Alternative Configurations: Drive Through (DT)Alternative Options: Pre-Filtered (PF) Pressurized (P)*Standard Sizing of Width and Height are in Increaments of 2(ft)^Standard Length Sizing is Illustrated above
Industrial Truck Wood
HEAVY DUTY DOWNDRAFT
COL-MET SPRAY BOOTHS COMPLY WITH ALL APPLICABLE OSHA AND NFPA REGULATIONS
OVERVIEW The Heavy Duty Downdraft Booth takes in fresh air from the cleaner upper levels of the shop, through a filtered booth ceiling. The filtered air is drawn down and away from the product through exhaust filters in the pit located in the floor. This providesefficient overspray control that reduces prep time and also provides a much healthier workplace environment. An optional above ground basement exhaust plenum is available for installation without concrete work.This booth can be purchased with a pre-filtered plenum or with a pressurized intake plenum. It can also be equipped with an air replacement unit and cure cycle to meet your requirements. The Heavy Duty Downdraft Booth is available in either drive-through or solid back configurations.LIGHTING FEATURESBright, full booth illumination is provided by four-tube, 48", 32-watt fluorescent light fixtures in the angled ceiling panels and side walls. All fixtures are UL listed and approved for their intended use and placement.
W6x9 beam steelAll panels and support members are precision punched for easy nut and bolt assembly5/16” bolt with self locking nuts for fastening panels every 6"fans and motorsdoors are pre-hung in a heavy gauge galvanized steel frame for easy installation.slotted hinges to facilitate
other electric components can be purchased separatelyPanel with VFD
Industrial Truck Wood
HEAVY DUTY DOWNDRAFT
Model Int. Dimensions (ft.) Option Configuration Access Nominal Door Opening Illumination Air Flow Fan Spec. FiltersNumber Width Height Length Doors Width Height Qty Type S&G Open Total SCFM Dia. HP Int. Exh
HDD-16-16-26-N-SB 16'-0" 16'-0" 26'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 20,800 42 7.5 38 26
HDD-16-16-28-N-SB 16'-0" 16'-0" 28'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 14 15 22,400 42 10 40 28
HDD-16-16-30-N-SB 16'-0" 16'-0" 30'-0" Non-Pressurized (N) Solid Back (SB) 1 11'-4" 13'-10" 1 Solid 1 17 18 24,000 42 10 44 30
HDD-16-16-40-N-SB 16'-0" 16'-0" 40'-0" Non-Pressurized (N) Solid Back (SB) 2 11'-4" 13'-10" 1 Solid 2 22 24 32,000 (2)42 (2)7.5 58 40
HDD-16-16-50-N-SB 16'-0" 16'-0" 50'-0" Non-Pressurized (N) Solid Back (SB) 3 11'-4" 13'-10" 1 Solid 3 27 30 40,000 (2)42 (2)7.5 72 50
HDD-16-16-60-N-SB 16'-0" 16'-0" 60'-0" Non-Pressurized (N) Solid Back (SB) 4 11'-4" 13'-10" 1 Solid 4 32 36 48,000 (2)42 (2)10 88 60
Sizing Option Ranges: 14-20* 12-20* ^
Reference Key A B C D E
Alternative Configurations: Drive Through (DT)Alternative Options: Pre-Filtered (PF) Pressurized (P)*Standard Sizing of Width and Height are in Increaments of 2(ft)^Standard Length Sizing is Illustrated above
Industrial Truck Wood
OVEN PANELS
CONSTRUCTION FEATURES AND QUALITY DETAILS
SHIPPING
UL CONTROL PANELS
Shipped pre-wired by Col-Met for easy and accurate hookup. Panel controls the exhaust fan and light operation of the spray booth. Panel includes a NEMA 12 enclosure, main disconnect switch, magnetic motor starter with overload disconnect and operative On/Off switch with fire protection interlock. Control Panels are designed for three (3) phase and single (1) phase operations. Consult your factory representative for further information. Not recommended for Col-Met Spray Booths featuring air make-up units, air balancing systems and / or infrared heaters.
OPTIONS / CUSTOM PANELS
All control panels fabricated by Col-Met
M PANELS
TUBEAXIAL BELT DRIVEN FAN
PERFORMANCESIZEAPPLICATIONSFEATURES
Fan Motor SCFM Motor Fan dBA Diameter HP @1/2" SP RPM RPM @5'
12" 3/4 1450 1725 2457 85 18" 3/4-1-1/2 1030-5000 1725 1245-2460 80-90 24" 1-3 5350-9050 1725-1750 1330-1960 88-96 30" 2-5 8850-15000 1750 1035-1500 84-92 36" 5 15296-18392 1750 860-979 87-89 42" 5-10 20263-32457 1750 830-1156 89-98
AERODYNAMIC BELT TUBEWITH STANDARD ACCESS DOOR MAINTENANCE-FREEBEARING ASSEMBLY
Fan Specifications *dBA subject to change depending on actual application