COL GIOVANNI PAOLO S.P.A.CORPORATE OVERVIEW
COMPANY DESCRIPTION
• COL Giovanni Paolo S.p.A. established in 1920, has assumed, during the years, a prestigious position inthe Electro Technical and Plant Engineering fields
• COL has consolidated its position on the National and International market, looking constantly forinnovative developments, suitable to carry the Company towards a total diversification, in fact it hasimplemented a policy of growth with the acquisition of companies in the Electronic, Environment,Systems, Railways and Electromechanical fields
• Today, COL is in the condition to offer a complete range of products and services, with elevatedtechnological contents, answering to the crescent requirement of the market and of the customers. Theexperience of the staff, matured and consolidated inside and outside the Company, concurs a qualifiedand specialized approach with the problematic ones of the fields, and represents the main resource
• Moreover, the great care of the technicians of the R. & D. to witch an equal percentage of 7% of theturnover is reserved, for the realization of new products and new technologies, guarantee the quality ofthe products
HEADQUARTER & M.V. PLANT
HEADQUARTER
Via Fratelli Ceirano, 20 - 10024 Moncalieri - Regione Vadò (TO) - Italy
Tel. +39 011 6474258 - Fax +39 011 6474546
web-site : www.colgp.it e-mail : [email protected]
EQUIPMENT AND SWITCHBOARDS FOR ELECTRIC POWER
Strada Provinciale 14, 93/95 - 95032 Piano Tavola - Belpasso (CT) - Italy
Tel. +39 095 7133088 - Fax +39 095 7131794
TURNOVER LAST 5 YEARS
€ 32.806.073,00
€ 28.346.136,00
€ 39.801.601,00
€ 46.472.901,00
€ 51.485.471,00
€ 36.927.847,00
€ 51.345.812,00
€ 0,00
€ 10.000.000,00
€ 20.000.000,00
€ 30.000.000,00
€ 40.000.000,00
€ 50.000.000,00
€ 60.000.000,00
TURNOVER
2008 2009 2010 2011 2012 2013 2014
COMMERCIAL PRESENCE IN THE WORLDEnel Distribuzione S.p.A.
Enel Power S.p.A.
Terna S.p.A.
Valdis S.p.A.
Deval S.p.A.
Trenitalia S.p.A.
Ferrovie Nord Milano
Metropolitana di Torino
RFI S.p.A.
OM Pimespo Carrelli Elevatori S.p.A.
A.E.T. S.p.A.
ABB Energy Automation
ABB Solution S.p.A.
ABB T&D S.p.A. – Divisione SAE
ABB SACE
ABB SAE Sadelmi
AEM Milano– A2A Distribution S.p.A.
AEM Torino
Daimler Chrystler Rail Systems Italia
S.p.A.
Sicomm s.r.l.
ACEA S.p.A.
Westinghouse
Thytronic
AMGA
Astea S.p.A.
Enia S.p.A.
HERA S.p.A.
Iride S.p.A.
Sab Wabco S.p.A.
Set Distribution S.p.A.
Schneider Electric
Omnitel Vodafone
Soc. Autostrade
Aziende Municipalizzate
Saint Gobain
Rete Gas Italia
Air Liquid
Snam Progetti
Ansaldo Trasporti
Faiveley Transport s.r.l.
Biticino
ENI
ESSO
Ferrari
Fiat
Pirelli
Montedison
ST Microelectronics
Alitalia
S.E.A.
Zanussi
U.S.A.
ARGENTINA
BRAZIL
CHILE
COLOMBIA
GERMANY
FRANCE
SPAIN
GREECE
IRELAND
SWITZERLAND
BELGIUM
ROMANIA
ALBANIA
CROATIA
MOROCCO
TUNISIA
ALGERIA
U.A.E.
JORDAN
EGYPT
SYRIA
PALESTINE
SAUDI ARABIA
TURKEY
CYPRUS
BAHRAIN
JAPAN
CHINA
INDONESIA
TAIWAN
INDIA
COMPANY’S STRENGTHS
• COL is a Company engaged in the world on the Electro Technical and Plant Engineering fields that will beincreasingly crucial to the mankind's welfare and for the planet preservation for the benefit of futuregenerations
• COL is a Company devoted to the design, construction and execution, with a unique background inmany technical fields, managerial and relational
• COL is the Italian Company with more versatile plant's offering
• COL is the union of more experience of historical Electro Technical Italian Companies
• Full plant service
• Electromechanical and electrical groundbreaking products
COMPANY’S STRENGTHS
• Agile, flexible and always much careful to the tendencies and to the needs of the market
• Constantly looking for innovation of our products
• Two R&D plants in Italy
• Attention to the quality of the products and the services
• Choice, qualification and surveillance of the suppliers
• Control during all the productive process
• Final control with tests executed in compliance with CEI-IEC standards
COMPANY’S STRENGTHS
• Management of the post-sale
• Formation and update of the staff
• Periodic examination of the system for the customer satisfaction
• Periodic examination of the system for the quality management
• TÜV SÜD Accreditation
VISION
• Increase our business to become one ofthe main actors of electronic andelectromechanical components in theelectricity and in the railway sector inItaly and around the world, capitalizingon the expertise of our staff and thecontinued growth and additional skillsacquisition for our company
• As one of the Italian leadingElectromechanical companies, we helpour customers to use electrical powerefficiently, to increase industrialproductivity and to lower environmentalimpact in a sustainable way
MISSION
On the basis of our advanced technology and solutions we respond to the most tough questions of ourtime in the Electromechanical, Plant Design and Energy sectors. Our wide range of products and solutionsare designed with the environment in mind and engage with the subject of climate change
• Improve performance of theproductivity, reliability and efficiency
• Improve the products efficiency with asustained commitment to R&D
• Act responsibly in terms ofsafe-environmental, social-responsibilityand business ethics
VALUES
• Customer satisfaction
• Our employees with their professionalexperience and customer devotion is ouradded value
• Our actions aimed to a continuousimprovement
• Constant carefully and looking for theQuality and technological innovation areon the basis for our business competition
THE COL G.P. BUSINESS
ELECTROMECHANICAL – M.V. DIVISIONM.V. EQUIPMENT
• Rotary, air insulated switch-disconnectors for M.V. metal enclosedswitchboards up to 24kV
• M.V. three pole SF6 Vacuum CircuitBreakers, indoor version 12/36kV
• M.V. three pole Vacuum CircuitBreakers, indoor version 12/36kV
• On load switch SF6 disconnectors upto 24kV
• M.V. overhead on load switchdisconnectors for secondary network
• Wall type switchgear disconnector
• Pole mounted outdoor version switchdisconnector for MV network
M.V. SWITCHBOARDS
• Air and SF6 gas insulated M.V. switchboards forsecondary substation up to 24kV
• Metal enclosed M.V. switchboards for primarysubstation
• M.V. switchboards type Metal-Clad up to 36kV
• Pole mounted SF6 on load switch disconnectors outdoorversion up to 24kV
• Reinforced concrete housing and relative switchboardsfor secondary and primary distribution network
• Steel substations with switchboards for emergencypower supply of primary and secondary substations
• Steel substations for power factor correction of M.V. andH.V. distribution networks
• Mobile stainless steel station for secondary network
• Pocket Substation
• Switch disconnector units for Petersen’s coil connection
• Auxiliary service boards for primary distribution
• Mosaic synoptic boards for whole vision and controlplants
• L.V. switchboards type Power Center e Motor ControlCenter
• Programmable logic control integrative systems forcontrol and protection of production transmission anddistribution HV/HV and HV/MV power plants andsubstations
RING MAIN UNIT
VCB FUSES EXTENSIBLE
• RMU switchgears are SF6 insulated equipment designed for use in secondary ring-main type network
• Designed for transformers up to 2000 KvA or for shunting stations
• The switching assembly is all installed in an arc fault proof, gas-tight, stainless steel enclosure
• Access to operating mechanisms, indicators and fuses in from the front of the switchgear
RMU 24 switchgear satisfies thefollowing requirements:
• Personnel safety
• Ease of installation
• Operative reliability
• Compact design
• Maintenance free
• Enclosure protects againstexternal influences
THREE POLE CIRCUIT BREAKER
SF6 VCB
• The three pole circuit breaker are designed in SF6 and VCB
• SF6 circuit breaker are adopted in installations with rated voltage up to 36 kV, rated current up to 2500 A and rated breaking capacity up to 25 kA
• VCB series of medium voltage Vacuum Circuit-Breakers is used in installations with rated voltages up to 24 kV and with rated currents up to 1250 A
Three Pole Circuit Breaker havebeen designed to satisfy thefollowing requirements:
• High reliability
• Personnel safety
• Simple to install
• Operation safety
• Minimum maintenance
M.V. PRODUCTIONS
IMS RGE ICS N SERIES• IMS is made for aerials lines
with insulating conductors andis in compliance with theinternational rule IEC 298
• This equipment can be installedeasily on the mountains, nearthe sea, in the towns and inopen country, because islife-sealed and can tolerate allclimatic conditions
• The equipment is designed for ause without maintenance
• RGE M.V. switchgear for indoor
use is constructed by placing
standardised units side by side
in a coordinated way.
• RGE switchgear is pre-set for:“G6” type SF6 gas circuit-breakers, “VCB” type vacuumcircuit-breakers, “IR3” type SF6gas switch-disconnectors
• RGE switchgears arecharacterized by extremelyreduced overall dimensions,easy inspection and fastmaintenance
ICS Series modular enclosed
switchboards are used typically
into the secondary substation to
restore the normal condition on
the electrical networks breaking
and re-establish the fault
current in selective compliance
with the circuit breaker installed
inside the primary substation for
neutral and condensed system
networks
N SERIES metal enclosed
switchboards have a self-supporting
structure and can be mounted
against the wall; they assure:
• Maximum Service Reliability
• Easy Installation
• Personal Safety Guaranteed by
PLANT ENGINEERING AND SERVICES
ENGINEERING
• Multidisciplinary design for transmission,distribution for substations and plants
• Design of control system and protection ofsubstations and plants
• SCADA automation and control system
• Project coordination
• HV electromechanical design and study
• Civil and structural design and study
• Supervision for Civil and Structural works
• Dimensions and current calculation for thechoice of the protections
• Technical assistance and advice for theactivity of electrical plant
PLANT ENGINEERING
• Demolition and re-construction of powerplants
• HV substations and lines constructions
• Primary and secondary substationsconstruction
• Hydroelectric power plant construction
• Electro-instrumental erection for thermicpower plants
• Installation and supply of Signalling Ballswith heliborne system
• Supply and installation of the equipment ofsquare, included the civil and structuralworks
• Construction of electrical conversionsubstations works and/or adaptations
• Realization of control systems for lightmetropolitan SAFT technology Matra-Siemens
ELECTRONIC AND SYSTEMDIGITAL PROTECTION RELAYS,
SIGMA N E SIGMA S LINES• Overcurrent and earth fault
• Overcurrent, earth fault, autoreclosure, breakerfailure
• Overcurrent, earth fault and directional earth fault
• Over/undervoltage, residual overvoltage or voltagebalance
• Earth fault directional overcurrent or directionalpower
• Motor protection
• Directional overcurrent and earth fault withautoreclosure or minimum impedance
• Busbar differential
• Voltage and frequency relay
• Over/underfrequency, overfluxing, max frequencyrate of change, max voltage vector shift
• Unbalanced load, stator overtemperature,overcurrent and stator earth fault
• Loss of field, rotor earth fault and antimotoring
• Generator differential and selective earth fault
• Transformer differential and overcurrent
• Syncro-check
• Voltage regulator for tap changer or voltageequalizer for generators
• Breaker failure device
• 100% stator earth fault
• Loss of step
OTHER DEVICES
• Generator and generator/transformer protectionand measuring systems
• DV9XX A2 NCI - protection panels compliant withEnel specifications
• LW53X - HV circuit breakers closing devicescompliant with Terna specifications
• Distance protection relays
• Measurement multifunction transducers compliantwith Fault recorders compliant with Enel spec’s andsoftware COLAnalyzer
• Terna specifications
POWER DISTRIBUTION AUTOMATION
UP - PERIPHERAL UNIT
UP is a Peripheral Unit for the telecontrolof M.V. secondary substations
There are two different model of UP:
• UP Indoor
• UP Outdoor
UP Main Functions:
• Medium Voltage Network Monitoring
• Secondary substation remote control
• Fault Branches isolation
UP interfaces:
• M.V. network main control systemSCADA with IEC 60870-5-104, IEC60870-5-101, IEC 61850
• M.V. devices (Switchboards,Switchbreakers, Reclosers) and FaultDetection Devices (RGDAT)
RGDAT UP
RGDAT is a bidirectional fault
and lower tension detector
for secondary M.V. and L.V.
cabin
RMU
UP
RGDAT
Voltage/Current Sensors
RMU Control
UP Communication
SYSTEMS PROTECTION
SIGMA-N PROTECTION
SIGMA-N are the digital protection relaysand measurement transducers developedand manufactured by COL (SEB Division)for M.V generation and distribution plants
SIGMA-N are characterized by:
• High reliability
• Wide range of available models
• Functions protection for distributionand generator
• Modbus RS485
MEASUREMENT TRANSDUCERS
Multifunction Transducers are based onthe SIGMA-N digital protection relaytechnology
They measure the electrical parametersof a H.V. or M.V. systems to produceanalogue impressed current signals
Multifunction Transducers arecharacterized by:
• 7 programmable analog outputs inimpressed current
• Alarm Thresholds
• Modbus RS485 RS232
NUMERIC DEVICES FOR H.V. SWITCH CLOSURE
The Numeric Devices for H.V. SwitchClosure provides 5 different models,configured in according to the functionalitythey need to do:
• Closure and automatic reset line (LW530)
• Closing primary transformer (LW 531)
• Closing secondary transformer (LW532)
• Closing parallel bars (LW 533)
• Control busbar voltages (LW 534)
Also Numeric Devices for H.V. SwitchClosure is Modbus RS485
PROTECTION AND MONITORING
DV7036 - DISTANCE PROTECTION
The DV7036C plays distance protection functions and monitoring for theprimary substations
LINE PROTECTION:
TRANSIENT RECORDER
• Up High performance solution for monitoring and maintenance of electric systems. Fitted to be installed with other devices. Up to 32 analog inputs
• to 128 digital inputs
• GPS Synchronization
• Serial interface or Ethernet interface
• DC analog signals measures (eg. batteries, UPS, etc.)
• AC analog signals measures
• High accuracy
• High pass band
• Total recording length 180 seconds when all channels are recording
• Distance protection
• Emergency (Max Current)
• Earth faults with high resistance(directional earth)
• Conductor interruption
• Anti-short cycle
• Teleprotection
• Automatic reclosing
• Fault detection
• Logging events
• Oscilloperturbography
• System remote Communication
• Auxiliary processing
HV/MV SUBSTATION AUTOMATION
BAY CONTROL AND MONITORING UNITHARDWARE KEY FEATURES
• Up to 8 high precision analogue input(4 Current/4 Voltage inputs or 8 Voltage inputs)
• Up to 220 digital inputs
• Up to 90 digital outputs
• Unmodulated optical fiber IRIG-B timesynchronization
• Two redundant optical fiber Ethernetconnections for IEC 61850 protocol
• One local Ethernet connection (optical fiber orcopper available) for configuration/local devicesconnection
• One local RS232 connection for configuration
• One local RS232 connection for configuration
• Local HMI (10 Led, 2x16 alphanumericdisplay, 6 key)
SOFTWARE AND PROTOCOLS KEY FEATURES
• IEC 61131 Soft logic (analogue and digitalvariables are available in the soft logic)
• Internal event report (up to 1000 events)
• Power measurement (P, Q, S)
• Energy measurement
• Synchronism (syncrocheck) algorithm
• Voltage regulator algorithm
• IEC 61850
NUMERIC DEVICES FOR H.V. SWITCH CLOSURE
ENM SCADA system, installed in electricalstations, is used for the registration ofdisturbances and events for themonitoring of the HV and HHV electricalnetwork, also for the monitoring of thecomponents HV and HHV status and forthe information acquisition about theemergency activities
The system guarantees the datatransmission relating to the electricalnetwork monitoring to the networkcontrol centres
The UN COL9000 (Bay Control andMonitoring Unit) represent the unit to baylevel for the data processing andtransmission
RAILWAYCARRIAGE ROAD
• Box for electrical contact carrier for automaticcoupling
• Biphase generator for the axis for antiskid devices
• Biphase stator for anti-skid device
• Mechanical controls switches for closing doorssignal
• Remote control switches
• Electromagnetic switches
• Relays
• Copper plait for pantographs
• Flexibles power connections
• Flexibles earth connections
• Brush – holder for earthing between trolley andchassis
• Main contacts for extra-fast switches
• Arcing contacts for extra-fast switches
• Power connectors for conditioning systems
• Knife switch
• Clamp – holder boxes
• Insulating strips
STATIC FLASHLIGHTS
• Static flashlight for railway and L.C. signals for FS 58 andFS 80 counterplates
• Static flashlight for repetition light with feed 50 Hz and83.3 Hz, for counterplates FS 58
DIFFERENTIAL DETECTORS
• Differential detector for the contact of fixed light signal’slamp with static commutation
CONTACTS FOR CONNECTOR 40 WAYS FS 82
• Male contact for wires from 0.5, 0.5+0.5 and 1 mmq
• Male contact for wires from 1+1, 2.5 and 4 mmq
• Female contact for wires from 0.5, 0.5+0.5 and 1 mmq
• Female contact for wires from 1+1, 2.5 and 4 mmq
• Springs for short-circuit female contact
• Springs for short-circuit male contact
• Signaling system of the ACEI installations with theintegration of the remote control according to theschemes of RFI of the series V400 and V401, A.AP.17 andIO/17 (ACEI = Central Electric Apparatus with route pushbutton control)
ENVIRONMENT
MAINTANCE DECONTAMINATION ANALYSES WASTEOverhauling and
electromechanical repair
of electrical equipments
and transformers
HV/MV/LV in air, in
mineral oil and PCB
Repair, maintenance and
austempering of electrical
equipments and
transformers in PCB or by
them contaminated
The activity can be
effectuated on site and in
the two plants of
Moncalieri, witch are
suitable equipped and
have a testing room
The analytics
methodologies have
been put to point by
our technicians in
collaboration with
University Institutes
and in compliance with
the ASTM, EPA, CEI, IEC
standards
Transport, withdrawal on
all the national and
international territory
Temporary storage,
treatment and shipment
to incineration of
materials contaminated,
generated by the
maintenance activities,
repair and treatment
THANK YOU FOR YOUR ATTENTION