10

Click here to load reader

Cobas e411 special_chemistry_analyzer

Embed Size (px)

Citation preview

Page 1: Cobas e411 special_chemistry_analyzer

COBAS e411 SPECIAL CHEMISTRY

ANALYZERPresented by: Mr.Shahid Nawaz

M.Sc ChemistryObesity Research Center

KSU , Saudi Arabia07/05/2011

Page 2: Cobas e411 special_chemistry_analyzer
Page 3: Cobas e411 special_chemistry_analyzer

BENEFITS

• Benefits:• 1 – Easy to use• 2 - Random Access• 3 - 88 Test/Hour • 4- Qualitative and Quantitative both test can be run.• 5- ECL (Electrchemiluminescence )Technology

6- Sample Volume required/Test 10-50 Ul7- Volume required in Standard Hitachi cup 150 uL and Reduced volume is 60 ul in primary sample tube.8- Touch Screen9- Database storage upto 2000 results.

Page 4: Cobas e411 special_chemistry_analyzer

CONSUMABLES

• Distilled Water: ≤ 10 uS/cm or ≥ 0.1 megohm• Assay Tips(120 per Tray)• Assay Cup (60 per Tray)• Hitachi Cups or Primary Tubes• Solid waste tray

Page 5: Cobas e411 special_chemistry_analyzer

SYSTEM REAGENT

Procell • Conditioning of the Electrode.• Transport of the assay reaction mixture• Washing of the streptavidin coated microbeads

Cleancell • Cleaning of the tubing system and of the measuring cell after every measurement.

Conditioning of the Electrode.Sysclean Sodium Hypochlorite Solution used for the cleaning of the measuring cell

(every two weeks)Syswash Increasing rinsing efficiency between pipetting steps

Preventing Bacterial GrowthSyswash added to the Distilled water container, with a dilution of 1+100.

Page 6: Cobas e411 special_chemistry_analyzer

COST OF CONSUMABLES

S.NO ITEM PACKING SIZE TOTAL PRICEUNIT PRICEIN SR

COST/TESTIN SR

1 Assay Tips(120 per Tray) 30x120 759.0 4.74 9.49

2 Assay Cup (60 per Tray) 60x60 526.0 6.84 6.84

3 Hitachi Cups 5000/Box 918.0 0.183 0.183

4 Sys Wash 500 mL /kit 69.0 69.0/kit 0.012

5 Clean Liner Tray 1x14 Bags 558.0 39.86/Bag 0.04

6 Procell 6x380 mL 353.0 58.8/BTL 0.327

7 Cleancell 6X380 mL 332.0 55.3/BTL 0.307

8 ISE Cleaning Solution 5x100 mL 286.0 57.2/BTL 0.057

Total Cast/Test 17.526 SR

Page 7: Cobas e411 special_chemistry_analyzer

• Calculation Formula: 2 Tips/Test; 4.74x2 = 9.49 SR• Sys Wash : 30mL/3 L Water = 500/10 = 500mL is enough for 50 L• 3L Sys Wash for 250 Test• One Clean Liner Tray for 540 Tips= 0.04 • Procell =

Page 8: Cobas e411 special_chemistry_analyzer

LIST OF TESTS

• Thyroid : T3,T4,FT4,TSH,FT3• CARDIAC: CKMB,Troponin T/hs(TnT)• INFERTILITY:FSH,LH,PRO,E2,PROG,TESTO,h

CG• INFECTIOUS DISEASE: Anti HCV,HIV,….• ANEMIA: FERRITIN,V12,FOLATE• Tumor Marker: PSA,CA125,CA 15-3,CA15-5• BONE: Vit D3,β CrossLaps,Osteocalcin,PTH,

Page 9: Cobas e411 special_chemistry_analyzer

Parameters

• FT4• TSH• Vit.D3• PTH• B-Cross Laps• N-Mid Osteocalcin

Page 10: Cobas e411 special_chemistry_analyzer

COST OF KITS

TEST Volume Required Cost of the Kit Cost of Calibrator Cost of Control Per TestCost

FT4 15 uL 2251/200 Test 218 SR 330 SR 14.63

TSH 50 uL 2251/200 Test 218 SR 330 SR 14.63

Vit.D3 35 uL 3011/100 Test 698 SR 268 SR 41.86

PTH 50 uL 1027/100 Test 236 SR 268 SR 14.80

B-Cross Laps 50 uL 1536/100 Test 514 SR 268 SR 23.50

N-Mid Osteocalcin 20 uL 1613/100 Test 514 SR 268 SR 24.40