Coaxial Cable Specifications
Dielectric TypeTime Delay
(ns/ft)
PropagationVelocity(% of c)
Solid Polyethylene (PE) 1.54 65.9Foam Polyethylene (FE) 1.27 80.0Foam Polystyrene (FS) 1.12 91.0Air Space Polyethylene (ASP) 1.15-1.21 84-88Solid Teflon (ST) 1.46 69.4Air Space Teflon (AST) 1.13-1.20 85-90
Properties for popular coaxial cables are listed below.c = speed of light in vacuum
Type (/U) MIL-W-17 Z0(Ω)Dielectric
TypeCapacitance
(pF/ft)O.D.(in.)
dB/100 ft@400 MHz
Vmax(rms)
Shield
RG-4 50.0 PE 30.8 0.226 11.7 1,900 BraidRG-5 52.5 PE 28.5 0.332 7.0 3,000 BraidRG-5A/B 50.0 PE 30.8 0.328 6.5 3,000 BraidRG-6 /2-RG6 76.0 PE 20.0 0.332 7.4 2,700 BraidRG-6A /2-RG6 75.0 PE 20.6 0.332 6.5 2,700 BraidRG-8 52.0 PE 29.6 0.405 6.0 4,000 BraidRG-8A 52.0 PE 29.6 0.405 6.0 5,000 BraidRG-9 51.0 PE 30.2 0.420 5.9 4,000 BraidRG-9A 51.0 PE 30.2 0.420 6.1 4,000 BraidRG-9B 50.0 PE 30.8 0.420 6.1 5,000 BraidRG-10 52.0 PE 29.6 0.463 6.0 4,000 BraidRG-10A 52.0 PE 29.6 0.463 6.0 5,000 BraidRG-11 /6-RG11 75.0 PE 20.6 0.405 5.7 4,000 BraidRG-11A /6-RG11 75.0 PE 20.6 0.405 5.2 5,000 BraidRG-12 /6-RG12 75.0 PE 20.6 0.463 5.7 4,000 BraidRG-12A /6-RG12 75.0 PE 20.6 0.463 5.2 5,000 BraidRG-17A 52.0 PE 29.6 0.870 2.8 11,000 BraidRG-22 /15-RG22 95.0 PE 16.3 0.405 10.5 1,000 BraidRG-22A/B /15-RG22 95.0 PE 16.3 0.420 10.5 1,000 BraidRG-23/A /16-RG23 125.0 PE 12.0 0.650 5.2 3,000 BraidRG-24/A /16-RG24 125.0 PE 12.0 0.708 5.2 3,000 BraidRG-34 /24-RG34 71.0 PE 21.7 0.625 5.3 5,200 BraidRG-34A /24-RG34 75.0 PE 20.6 0.630 5.3 6,500 BraidRG-35 /64-RG35 71.0 PE 21.7 0.928 2.8 10,000 BraidRG-35A/B /64-RG35 75.0 PE 20.6 0.928 2.8 10,000 BraidRG-55B 53.5 PE 28.8 0.200 11.7 1,900 BraidRG-58 /28-RG58 53.5 PE 28.8 0.195 11.7 1,900 BraidRG-58A /28-RG58 52.0 PE 29.6 0.195 13.2 1,900 BraidRG-58B 53.5 PE 28.8 0.195 14.0 1,900 Braid
RG-58C /28-RG58 50.0 PE 30.8 0.195 14.0 1,900 BraidRG-59/A /29-RG59 73.0 PE 21.1 0.242 10.5 2,300 BraidRG-59B /29-RG59 75.0 PE 20.6 0.242 9.0 2,300 BraidRG-62/A/B /30-RG62 93.0 ASP 13.5 0.242 8.0 750 BraidRG-63/A/B /31-RG63 125.0 ASP 10.0 0.405 5.5 1,000 BraidRG-65/A /34-RG65 950.0 ASP 44.0 0.405 16 @5MHz 1,000 BraidRG-71/A/B /90-RG71 93.0 ASP 13.5 0.245 8.0 750 BraidRG-79/A/B /31-RG79 125.0 ASP 10.0 0.436 5.5 1,000 BraidRG-83 35.0 PE 44.0 0.405 9.0 2,000 BraidRG-88 48.0 50.0 0.515 0.7 @1MHz 10,000 BraidRG-108/A /45-RG108 78.0 PE 19.7 0.235 2.8 @10MHz 1,000 BraidRG-111/A /15-RG111 95.0 PE 16.3 0.478 10.5 1,000 BraidRG-114/A /47-RG114 185.0 ASP 6.5 0.405 8.5 1,000 BraidRG-119 /52-RG119 50.0 ST 29.4 0.465 3.8 6,000 BraidRG-120 /52-RG120 50.0 ST 29.4 0.523 3.8 6,000 BraidRG-122 /54-RG122 50.0 PE 30.8 0.160 18.0 1,900 BraidRG-130 /56-RG130 95.0 PE 17.0 0.625 8.8 3,000 BraidRG-131 /56-RG131 95.0 PE 17.0 0.683 8.8 3,000 BraidRG-133/A /100-RG133 95.0 PE 16.3 0.405 5.7 4,000 BraidRG-141/A 50.0 ST 29.4 0.190 9.0 1,900 BraidRG-142/A/B /60-RG142 50.0 ST 29.4 0.195 9.0 1,900 BraidRG-144 /62-RG144 75.0 ST 19.5 0.410 4.5 5,000 BraidRG-164 /64-RG164 75.0 PE 20.6 0.870 2.8 10,000 BraidRG-165 /65-RG165 50.0 ST 29.4 0.410 5.0 5,000 BraidRG-166 /65-RG166 50.0 ST 29.4 0.460 5.0 5,000 BraidRG-174 50.0 30.5 0.110 14.7 BraidRG-177 /67-RG177 50.0 PE 30.8 0.895 2.8 11,000 BraidRG-178/A/B /93-RG178 50.0 ST 29.4 0.072 29.0 1,000 BraidRG-179 /94-RG179 70.0 ST 20.9 0.100 21.0 1,200 BraidRG-179A/B /94-RG179 75.0 ST 19.5 0.100 21.0 1,200 BraidRG-180 /95-RG180 93.0 ST 15.4 0.140 17.0 1,500 BraidRG-180A/B /95-RG180 95.0 ST 15.4 0.140 17.0 1,500 BraidRG-210 /97-RG210 93.0 ASP 13.5 0.242 8.0 750 BraidRG-211/A /72-RG211 50.0 ST 29.4 0.730 2.3 7,000 BraidRG-212 /73-RG212 50.0 PE 29.4 0.332 6.5 3,000 BraidRG-213 /74-RG213 50.0 PE 30.8 0.405 5.5 5,000 BraidRG-214 /75-RG214 50.0 PE 30.8 0.425 5.5 5,000 Dbl BraidRG-215 /74-RG215 50.0 PE 30.8 0.463 5.5 5,000 BraidRG-216 /77-RG216 75.0 PE 20.6 0.425 5.2 5,000 BraidRG-217 /78-RG217 50.0 PE 30.8 0.545 4.3 7,000 BraidRG-218 /79-RG218 50.0 PE 30.8 0.870 2.5 11,000 BraidRG-219 /79-RG219 50.0 PE 30.8 0.928 2.5 11,000 BraidRG-223 /84-RG223 50.0 PE 19.8 0.211 8.8 1,900 Dbl BraidRG-302 /110-RG302 75.0 ST 19.5 0.201 8.0 2,300 BraidRG-303 /111-RG303 50.0 ST 29.4 0.170 9.0 1,900 BraidRG-304 /112-RG304 50.0 ST 29.4 0.280 6.0 3,000 BraidRG-307/A /116-RG307 75.0 80 16.9 0.270 7.5 1,000 BraidRG-316 /113-RG316 50.0 ST 29.4 0.102 20.0 1,200 BraidRG-391 /126-RG391 72.0 23.0 0.405 15.0 5,000 BraidRG-392 /126-RG392 72.0 23.0 0.475 15.0 5,000 Braid
RG-393 /127-RG393 50.0 ST 29.4 0.390 5.0 5,000 BraidRG-400 /128-RG400 50.0 ST 29.4 0.195 9.6 1,900 BraidRG-401 /129-RG401 50.0 ST 29.4 0.250 4.6 3,000 Cu. S-RRG-402 /130-RG402 50.0 ST 29.4 0.141 7.2 2,500 Cu. S-RRG-403 /131-RG403 50.0 ST 29.4 0.116 29.0 2,500 BraidRG-405 /133-RG405 50.0 ST 29.4 0.086 13.0 1,500 Cu. S-R9914 (Belden) 50.0 26.0 0.405 10.0 ------
Common Coaxial Cables
type
impedanc
e
ohms
coreDielectri
c Type
Dielectri
c VF
Dielectri
c in
Dielectri
c mm
O
D
in
OD
m
m
shield
scomments
max
attenuation
@ 750 MHz
RG-6/U 75 1.0 mm PF 0.75 0.185 4.7 0.270 6.86 double
Low loss at high
frequency for cable
television,satellite
television and cable
modems
05.65dB/100 ft
RG-6/UQ 75 PF 0.298 7.57 quad
This is "quad shield RG-
6". It has four layers
ofshielding; regular RG-
6 has only one or two
05.65dB/100 f
t[15]
RG-7 75 1.30 mm PF 0.225 5.72 0.320 8.13 double
Low loss at high
frequency for cable
television,satellite
television and cable
modems
04.57dB/100 ft
RG-8/U 50 2.17 mm PE 0.285 7.2 0.405 10.3Amateur radio; Thicknet
(10BASE5) is similar
05.967
dB/100 ft[16]
Common Coaxial Cables
type
impedanc
e
ohms
coreDielectri
c Type
Dielectri
c VF
Dielectri
c in
Dielectri
c mm
O
D
in
OD
m
m
shield
scomments
max
attenuation
@ 750 MHz
RG-8X 50 1.0 mm PF 0.75 0.185 4.7 0.242 6.1 double
A thinner version, with
the electrical
characteristics of RG-8U
in a diameter similar to
RG-6.[17]
10.946
dB/100 ft[16]
RG-9/U 51 PE 0.420 10.7
RG-11/U 75 1.63 mm PE 0.66 0.285 7.2 0.412 10.5Triple/
Quad
Used for long drops and
underground conduit[18]03.65dB/100 ft
RG-56/U 481.4859 m
m0.535 13.589 Dual/Quad Cable TV installations
RG-58/U 50 0.81 mm PE 0.66 0.116 2.9 0.195 5.0 single Used for
radiocommunication
and amateur radio, thin
Ethernet (10BASE2)
and NIMelectronics,
13.104
dB/100 ft[16]
Common Coaxial Cables
type
impedanc
e
ohms
coreDielectri
c Type
Dielectri
c VF
Dielectri
c in
Dielectri
c mm
O
D
in
OD
m
m
shield
scomments
max
attenuation
@ 750 MHz
Loss 1.056 dB/meter @
2.4 GHz. Common.[19]
RG-59/U 75 0.81 mm PE 0.66 0.146 3.7 0.242 6.1 single
Used to
carry baseband video
in closed-circuit
television, previously
used for cable television.
In general, it has poor
shielding but will carry
an HQ HD signal or
video over short
distances.[20]
09.708
dB/100 ft[16]
3C-2V 75 0.50 mm PE 0.85 3.0 5.4 single
Used to carry television,
video observation
systems, and other. PVC
jacket.
5C-2V 75 0.80 mm PE 0.82 +/-2 0.181 4.6 0.256 6.5 double Used for interior lines for
Common Coaxial Cables
type
impedanc
e
ohms
coreDielectri
c Type
Dielectri
c VF
Dielectri
c in
Dielectri
c mm
O
D
in
OD
m
m
shield
scomments
max
attenuation
@ 750 MHz
monitoring system,
CCTV feeder lines,
wiring between the
camera and control unit
and video signal
transmission. PVC
jacket.
RG-60/U 50 1.024 mm PE 0.425 10.8 single
Used for high-definition
cable TV and high-
speed cable Internet.
RG-62/U 92 PF 0.84 0.242 6.1 single
Used for ARCNET and
automotive radio
antennas.[21]
RG-62A 93 ASP 0.242 6.1 single Used for NIM electronics
Common Coaxial Cables
type
impedanc
e
ohms
coreDielectri
c Type
Dielectri
c VF
Dielectri
c in
Dielectri
c mm
O
D
in
OD
m
m
shield
scomments
max
attenuation
@ 750 MHz
RG-142 50 4.95 double RG-142.pdf
RG-174/U 507x0.16 m
mPE 0.66 0.059 1.5 0.100 2.55 single
Common for wifi pigtails:
more flexible but higher
loss than RG58; used
with LEMO 00
connectors
in NIM electronics.
23.565
dB/100 ft[16]
RG-178/U 50
7×0.1 mm
(Ag-plated
Cu-clad
Steel)
PTFE 0.69 0.033 0.84 0.071 1.8 singleUsed for high-frequency
signal transmission.[22]
42.7 dB/100 ft
@ 900 MHz[23]
RG-179/U 75
7×0.1 mm
(Ag-plated
Cu)
PTFE 0.67 0.063 1.6 0.098 2.5 single VGA RGBHV[24]
Common Coaxial Cables
type
impedanc
e
ohms
coreDielectri
c Type
Dielectri
c VF
Dielectri
c in
Dielectri
c mm
O
D
in
OD
m
m
shield
scomments
max
attenuation
@ 750 MHz
RG-
180B/U95
0.0120 in
(Ag-plated
Cu-clad
steel)
PTFE 0.102 2.59 0.145 3.68
single Ag
covered
Cu
VGA RGBHV
RG-213/U 507×0.0296
in CuPE 0.66 0.285 7.2 0.405 10.3 single
For radiocommunication
and amateur radio, EMC
test antenna cables.
Typically lower loss than
RG58. Common.[25]
05.967
dB/100 ft[16]
RG-214/U 507×0.0296
inPE 0.66 0.285 7.2 0.425 10.8 double
Used for high-frequency
signal transmission.[26]
06.702
dB/100 ft[16]
RG-218 500.195 in
CuPE 0.66
0.660
(0.680?)
16.76
(17.27?)0.870 22 single
Large diameter, not very
flexible, low loss
(2.5dB/100' @
400 MHz), 11kV
dielectric withstand.
02.834
dB/100 ft[16]
Common Coaxial Cables
type
impedanc
e
ohms
coreDielectri
c Type
Dielectri
c VF
Dielectri
c in
Dielectri
c mm
O
D
in
OD
m
m
shield
scomments
max
attenuation
@ 750 MHz
RG-223/U 50 0.88 mm PE 0.66 0.0815 2.07 0.212 5.4 double
Silver-plated
shields. Sample RG-223
Datasheet
11.461
dB/100 ft[16]
RG-316/U 507x0.0067
inPTFE 0.695 0.060 1.5 0.098 2.6 single
used with LEMO 00
connectors
in NIMelectronics;[27]
22.452
dB/100 ft[16]
RG-400/U 5019x0.20m
mPTFE 2.95 4.95 double [28]
12.566
dB/100 ft[16]
H155 5019 x
0.28 mm0.79 5.4
lower loss at high
frequency for
radiocommunication
and amateur radio
H500 50 0.82 low loss at high
frequency for
radiocommunication
Common Coaxial Cables
type
impedanc
e
ohms
coreDielectri
c Type
Dielectri
c VF
Dielectri
c in
Dielectri
c mm
O
D
in
OD
m
m
shield
scomments
max
attenuation
@ 750 MHz
and amateur radio
LMR-100 50 2.79
low loss
communications, 1.36
dB/meter @ 2.4 GHz
20.725
dB/100 ft[16]
LMR-195 50 4.95
low loss
communications, 0.620
dB/meter @
2.4 GHz LMR195specs.
10.125
dB/100 ft[16]
LMR-200
HDF-200
CFD-200
501.12 mm
CuPF 0.83 0.116 2.95 0.195 4.95
low loss
communications, 0.554
dB/meter @ 2.4 GHz
09.035
dB/100 ft[16]
LMR-240 50 1.42 mm
Cu
PF 0.84 0.150 3.81 0.240 6.1 double Amateur radio, low loss
replacement for RG-
06.877
dB/100 ft[16]
Common Coaxial Cables
type
impedanc
e
ohms
coreDielectri
c Type
Dielectri
c VF
Dielectri
c in
Dielectri
c mm
O
D
in
OD
m
m
shield
scomments
max
attenuation
@ 750 MHz
8X[29]
LMR-400
HDF-400
CFD-400
50
2.74 mm
(Cu-clad
Al)
PF 0.85 0.285 7.24 0.405 10.29
low loss
communications, 0.223
dB/meter @ 2.4 GHz[30]
03.544
dB/100 ft[16]
LMR-600 50
4.47 mm
(Cu-clad
Al)
PF 0.87 0.455 11.56 0.590 14.99
low loss
communications, 0.144
dB/meter @ 2.4 GHz
02.264
dB/100 ft[16]
LMR-900 506.65 mm
(BC tube)PF 0.87 0.680 17.27 0.870 22.10
low loss
communications, 0.098
dB/meter @ 2.4 GHz
01.537
dB/100 ft[16]
LMR-1200 508.86 mm
(BC tube)PF 0.88 0.920 23.37 1.200 30.48
low loss
communications, 0.075
dB/meter @ 2.4 GHz
01.143
dB/100 ft[16]
Common Coaxial Cables
type
impedanc
e
ohms
coreDielectri
c Type
Dielectri
c VF
Dielectri
c in
Dielectri
c mm
O
D
in
OD
m
m
shield
scomments
max
attenuation
@ 750 MHz
LMR-1700 5013.39 mm
(BC tube)PF 0.89 1.350 34.29 1.670 42.42
low loss
communications, 0.056
dB/meter @ 2.4 GHz
0.844
dB/100 ft[16]
QR-320 75 1.80 mm PF 0.395 10.03 single
Low loss line, which
replaced RG-11 in most
applications
03.34dB/100 ft
QR-540 75 3.15 mm PF 0.610 15.49 single Low loss hard line 01.85dB/100 ft
QR-715 75 4.22 mm PF 0.785 19.94 single Low loss hard line 01.49dB/100 ft
QR-860 75 5.16 mm PF 0.960 24.38 single Low loss hard line 01.24dB/100 ft
QR-1125 75 6.68 mm PF 1.225 31.12 single Low loss hard line 01.01dB/100 ft
RG Cable type Specifications Dia. Braid Shield Nominal Nominal
Type Conductor Over Nom. Jacket Nom. Capaci- Attenua- Ins. Inner Outer O.D. Material Imped. tance tion No./mm MTRL mm No./mm No./mm mm ohm pF/m dB/km
RG-5/U 1/1.29 BC 4.7 16/9/0.16 16/9/0.16 8.4 PVC 52.5 93.5 85
RG-7/U 1/0.914 BC 6.35 24/7/0.18 ﹣ 9.4 PVC 94.5 41 66
RG-8/U 7/0.724 BC 7.24 24/8/0.18 ﹣ 10.3 PVC 52 96.8 69
RG-8A/U 7/0.724 BC 7.24 24/8/0.18 ﹣ 10.3 NC.PVC 52 96.8 69
RG-11/U 7/0.404 TC 7.24 24/8/0.18 ﹣ 10.3 PVC 75 67.3 76
RG-11A/U 7/0.404 TC 7.24 24/8/0.18 ﹣ 10.3 NC.PVC 75 67.3 76
RG-13/U 7/0.404 TC 7.11 24/9/0.16 24/8/0.16 10.7 PVC 74 67.3 76
RG-13A/U 7/0.404 TC 7.11 24/9/0.16 24/8/0.16 10.7 NC.PVC 74 67.3 76
RG-14/U 1/2.59 BC 9.4 24/10/0.18 24/8/0.18 13.8 PVC 52 96.8 46
RG-14A/U 1/2.59 BC 9.4 24/10/0.18 24/8/0.18 13.8 NC.PVC 52 96.8 46
RG-15/U 1/1.45 CCS 9.4 24/10/0.18 24/8/0.18 13.8 PVC 76 65.6 49
RG-17/U 1/1.478 BC 17.3 24/14/0.26 ﹣ 22.1 PVC 52 96.8 28
RG-17A/U 1/4.78 BC 17.3 24/14/0.26 ﹣ 22.1 NC.PVC 52 96.8 28
RG-19/U 1/6.35 BC 23.1 36/12/0.26 ﹣ 28.5 PVC 52 96.8 22
RG-19A/U 1/6.35 BC 23.1 36/12/0.26 ﹣ 28.5 NC.PVC 52 96.8 22
RG-22/U 7/0.386*2C BC 7.24 24/8/0.18 ﹣ 10.3 PVC 95 52.5 118
RG-22A/U 7/0.386*2C BC 7.24 24/8/0.16 24/8/0.16 10.7 PVC 95 52.5 118
RG-22B/U 7/0.386*2C BC 7.24 24/8/0.16 24/8/0.16 10.7 NC.PVC 95 52.5 118
RG-29/U 1/0.813 BC 2.95 16/7/0.127 ﹣ 4.7 PE 53.5±2.5 93.5 138
RG-34/U 7/0.724 BC 11.6 24/9/0.16 ﹣ 15.9 PVC 71±3 70.5 46
RG-34B/U 7/0.632 BC 11.7 24/10/0.18 ﹣ 16 NC.PVC 75±3 67 48
RG-54A/U 7/0.385 BC 4.52 16/9/0.16 ﹣ 6.1 PE 58±2.5 85.8 187
HG-55/U 1/0.813 BC 2.9 16/7/0.127 16/7/0.127 5 PE 53.5±2.5 93.6 138
RG-58/U 1/0.813 BC 2.95 16/7/0.127 ﹣ 4.95 PVC 53.5±2.5 93.5 138
RG-58A/U 19/0.18 TC 2.95 16/7/0.127 ﹣ 4.95 PVC 50±2 93.5 174
RG-58C/U 19/0.18 TC 2.95 16/7/0.127 ﹣ 4.95 NC.PVC 50±2 93.5 174
RG-59/U 1/0.643 CCS 3.71 16/7/0.16 ﹣ 6.15 PVC 73±3 68.9 125
RG-59A/U 1/0.643 CCS 3.71 16/7/0.16 ﹣ 6.15 NC.PVC 73±3 68.9 125
RG-59B/U 1/0.584 CCS 3.71 16/7/0.16 ﹣ 6.15 NC.PVC 75±3 68.9 112
RG-62/U 1/0.643 CCS 3.71 16/7/0.16 ﹣ 6.15 PVC 93 44.3 102
RG-62A/U 1/0.643 CCS 3.71 16/7/0.16 ﹣ 6.15 NC.PVC 93±5 44.3 102
RG-63/U 1/0.643 CCS 7.24 24/8/0.18 ﹣ 10.3 PVC 125 32.8 66
RG-63B/U 1/0.643 CCS 7.24 24/8/0.18 ﹣ 10.3 NC.PVC 125±6 32.8 66
RG-71/U 1/0.643 CCS 3.71 16/7/0.16 16/9/0.127 6.4 PE 93 44.3 102
RG-89/U 1/0.643 CCS 7.24 16/12/0.18 ﹣ 16 PVC 125 32.8 66
RG-108/U 7/0.32*2C TC 1.84 16/6/0.127 ﹣ 6.2 NC.PVC 78±6.5 74.3 ﹣
RG-108A/U 7/0.32*2C TC 2.01 16/6/0.127 ﹣ 5.97 NC.PVC 78±7 74.3 ﹣
RG-122/U 27/0.127 TC 2.44 16/6/0.127 ﹣ 4.06 NC.PVC 50±2 105 195
RG-130/U 7/0.724*2C BC 12 24/8/0.26 ﹣ 15.9 PVC 95±5 56 99
RG-133A/U 1/0.645 BC 7.2 24/8/0.18 ﹣ 10.3 NC.PVC 95 53 76
RG-164/U 1/2.65 BC 17.3 24/14/0.26 ﹣ 22.1 NC.PVC 75±3 67 30
RG-213/U 7/0.752 BC 7.24 24/8/0.18 ﹣ 10.3 NC.PVC 50±2 100 69
RG-216/U 7/0.404 TC 7.24 24/9/0.16 24/8/0.16 10.8 NC.PVC 75±3 67 88
RG-217/U 1/2.69 BC 9.4 24/10/0.18 24/8/0.18 13.8 NC.PVC 50±2 100 50
COAX TYPE CHARACTERISTIC
IMPEDANCE
OUTSIDE
DIAMETER
VELOCITY
FACTOR
ATTEN
@ 100 MHZ
ATTEN
@ 1000 MHZ
COMMENTS
RG5/U 52.5 8.4 0.66 1.0 3.8
RG6A/U 75 8.4 0.66 1.0 3.7
RG9/U 51.0 10.7 0.66 0.66 2.4
RG10A/U 50 12.1 0.66 0.66 2.6
RG11A/U 75 10.3 0.66 0.76 2.6
RG12A/U 75 12.1 0.66 0.76 2.6
RG20A/U 50 30.4 0.66 0.22 1.2
RG22 95 10.7 0.75 1.5
RG23 125 24.0 0.52 2.0
RG24 125 25.5 0.52 2.0
RG34 75 16.0 0.46 1.8
RG58C/U 50 5.0 0.66 1.8 7.6
RG59B/U 75 6.1 0.66 1.2 4.6
RG62A/U 93 6.1 0.84 0.9 2.8
RG63 125 10.3 0.6 2.1
RG79 125 12.1 0.6 2.1
RG108 78 6.0 1.1 3.8
COAX TYPE CHARACTERISTIC
IMPEDANCE
OUTSIDE
DIAMETER
VELOCITY
FACTOR
ATTEN
@ 100 MHZ
ATTEN
@ 1000 MHZ
COMMENTS
RG111 95 12.1 0.75 2.6
RG114 185 10.3 1.1 3.8
RG119 50 11.8 0.5 1.8
RG120 50 13.3 0.5 1.8
RG122 50 4.1 1.7 5.5
RG213/U 50 10.3 0.66 0.62 2.6 Polythene dielectric
RG214/U 50 10.8 0.66 0.76 2.9 Double screened, silver plated
copper wire
RG223/U 50 5.5 0.66 1.58 5.4
UR43 50 5 0.66 1.3 4.46
UR57 75 10.2 0.66 0.63 2.3 Similar to RG11A/U
UR67 50 10.3 0.66 0.66 2.52 Similar to RG213/U
UR74 51 22.1 0.66 0.33 1.4
UR76 51 5 0.66 1.7 7.3 Similar to RG58C/U
UR77 75 22.1 0.66 0.33 1.4
UR79 50 21.7 0.96 0.17 0.6
UR90 75 6.1 0.66 1.2 4.1 Similar to RG59B/U
Electrical Characteristics:
“Maximum frequencies” are those as referenced on individual slant sheets of the MIL-C-17 specification. No values are given for unswept constructionsas the specification recommends these cables should not be used above 400 MHz. All figures referenced above are nominal unless otherwise specified.Attenuation (dB/100ft) @M17 Number Impedance Capacitance Max Voltage 100 MHz 400 MHz 1 GHz 2.4 GHz 5 GHz 10 GHz Max Frequency(ohms) (pF/ft) Typ / Max Typ / Max Typ / Max Typ / Max Typ / Max Typ / Max (GHz)M17/60-RG142 50 +/- 2 29.4 1900 4.0 / 5.5 8.1 / 11.7 13.4 / 19.2 21.3 / 30.4 33.3 / 48.7 - 17.4M17/76-RG217 50 +/- 2 30.8 7000 1.5 / 1.6 3.5 / 3.7 6.7 / 7.0 - - - 3.0M17/93-RG178 50 +/- 2 29.4 1000 13.0 / 16.0 27.2 / 33.0 44.2 / 52.0 41.7 / 56.1 - - 3.0M17/93-00001 50 +/- 2 29.4 1000 13.0 / 16.0 27.2 / 33.0 44.2 / 52.0 41.7 / 56.1 - - 3.0M17/94-RG179 75 +/- 3 19.4 1200 8.0 / 9.2 15.5 / 21.0 26.7 / 30.7 - - - -M17/95-RG180 95 +/- 5 17.4 1500 5.7 / 6.6 11.7 / 17.4 19.2 / 23.0 - - - -M17/110-RG302 75 +/- 3 19.4 2300 - 7.2 / 8.0 - - - - -M17/111-RG303 50 +/- 2 29.4 1900 3.5 / 3.9 7.2 / 8.0 13.5 / 15.0 - - - -M17/112-RG304 50 +/- 2 29.4 3000 2.4 / 2.7 5.8 / 6.4 10.0 / 11.1 - - - 8.0M17/113-RG316 50 +/- 2 29.4 1200 7.6 / 11.0 16.0 / 21.0 26.2 / 38.0 41.2 / 55.4 - - 3.0M17/127-RG393 50 +/- 2 29.4 2500 2.3 / 2.5 4.4 / 5.0 7.7 / 9.2 12.4 / 14.2 21.3 / 26.8 30.1 / 37.9 11.0M17/128-RG400 50 +/- 2 29.4 1900 4.3 / 4.5 8.6 / 10.5 14.1 / 18.1 22.6 / 30.2 35.6 / 52.1 61.6 / 78.0 12.4M17/131-RG403 50 +/- 2 29.4 1000 - 33.3 / 37.0 - - - - 10.0M17/152-00001 50 +/- 2 29.4 1200 8.1 / 11.5 17.8 / 24.0 29.6 / 40.0 43.1 / 58.3 100.0 /110.0 153.0/170.0 12.4M17/158-00001 50 +/- 2 29.4 1900 - 8.1 / 9.5 - - - -M17/165-00001 50 +/- 2 29.4 7000 - 3.5 / 3.7 - - - -M17/169-00001 50 +/- 2 29.4 1000 - 27.2 / 29.0 - - - - -M17/170-00001 50 +/- 2 29.4 1900 - 7.7 / 8.6 - - - - -M17/172-00001 50 +/- 2 29.4 1200 - 15.5 / 21.0 - - - - -M17/174-00001 50 +/- 2 29.4 2500 - 4.4 / 5.0 - - - - -M17/175-00001 50 +/- 2 29.4 1900 - 8.6 /10.5 - - - - -M17/176-00001 77 +/- 7 19.0 1000 - - - - - - -PTFE Tape Wrap Jacketed RG CablesRG 187 A/U 75 +/- 3 19.4 1200 - 15.5 / 21.0 - - - -RG 188 A/U 50 +/- 2 29.4 1200 7.6 / 11.0 16.0 / 21.0 26.2 / 38.0 41.2 / 55.4 - - 3.0RG 195 A/U 95 +/- 5 17.4 1500 - 11.7 / 17.4 - - - -RG 196 A/U 50 +/- 2 29.4 1000 13.0 / 16.0 27.2 / 33.0 44.2 / 52.0 41.7 / 56.1 - - 3.0
COAXIAL CABLE SPECIFICATIONSMAJOR TYPES
DATA SHEET COMPILED BY PAUL HARDEN NA5N COAX CONDUCTOR INSULATION SHIELD JACKET
TYPE Strands Diameter Material Diameter Cover Material Diameter Velocity Factor pf/ft. Atten/100ft50 Ohm .
RG-8 7/19 0.108 FP 0.285 97% PE 0.405 0.78 26 0.5dbRG-8* 7/19 0.108 FP 0.285 *96% PE 0.480 0.78 26 0.5dbRG-8A 7/21 0.085 PE 0.285 97% NC 0.405 0.66 30 0.5dbRG-9* 7/21 0.86 PE 0.280 *96% NC 0.420 0.66 30 0.6dbRG-58 Solid 0.32 PE 0.116 95% PV 0.193 0.66 29 1.2
RG-58A 19/33 0.35 PE 0.116 96% PV 0.195 0.66 31 1.4dbRG-58A* 7/28 0.37 PE 0.114 *96% PV 0.240 0.66 31 1.5dbRG-58C 19/33 0.35 PE 0.116 96% NC 0.195 0.66 31 1.4dbRG-141# Solid 0.037 TF 0.116 #96% FG 0.190 0.70 29 1.1dbRG-174 7/34 0.019 PE 0.060 88% PV 0.101 0.66 31 3.3dbRG-223# Solid 0.035 PE 0.116 #*97% NC 0.212 0.66 31 1.2db
9913 Solid 0.108 FP 0.285 100% PV 0.405 0.84 24 0.4db72 Ohm
RG-11 Solid 0.064 FP 0.285 95% PV 0.405 0.78 17 0.4dbRG-11A 7/26 0.048 PE 0.285 97% PV 0.405 0.66 21 0.7dbRG-59 Solid 0.023 PE 0.146 95% PV 0.146 0.66 21 1.1dbRG-59* Solid 0.032 FP 0.143 *96% PE 0.315 0.78 17 1.0db
RG-59B Solid 0.023 PE 0.146 95% NC 0.242 0.66 21 1.1db
* = Double shielded Coax # = Silver plated centre conductor and shield
1. 1. Centre conductor is copper or tinned copper except where indicated by #2. 2. Insulation dielectric Codes PE: Polyethylene FP: Foam Polyethylene TF: High Temperature Teflon3. 3. Jacket Material Codes PE: Polyethylene PV: PVC NC: Non-contaminating FG: Fiberglass4. 4. VF = Velocity factor of coax (eg 0.66 = 66%)5. 5. pf/ft = Capacitance (in pf) per foot6. 6. Attenuation/100ft = coax attenuation per 100ft at 10Mhz7. 7. Diameters for centre conductor, insulation and jacket are used for selecting proper connector (BNC,
PL259, etc)
RG/U No.
Catalog No.
TypeNom. Imp.
Cap.Dielect.
Mat.Jacket Shield
Overall Diameter
Size (in) and
Type of Inner Cond.
1 N/A Waveguide N/A N/A N/A N/A N/A N/A N/A
2 N/A Waveguide N/A N/A N/A N/A N/A N/A N/A
3 N/A Waveguide N/A N/A N/A N/A N/A
0.226 in
5.74 mm
N/A
4507-
4Coax Cable 50 Ω
30.0 pF/ft98.4 pF/m
PE PVC-I2
BC
0.226 in
5.74 mm
0.0320 BC
5507-
5Coax Cable
52.5 Ω
28.5 pF/ft93.5 pF/m
PE PVC-I2
BC
0.332 in
8.43 mm
0.0508 BC
5A507-5A
Coax Cable 50 Ω
30.8 pF/ft101
pF/m
PE PVC-II 2 S
0.328 in
8.33 mm
0.0508 S
5B*507-5B
Coax Cable 50 Ω
30.8 pF/ft101
pF/m
PE PVC-IIA 2 S
0.338 in
8.59 mm
0.0508 S
6507-
6Coax Cable 75 Ω
22.0 pF/ft72.2 pF/m
PE PVC-IIBC-S
0.332 in
8.43 mm
0.0285 CW
6A*507-6A
Coax Cable 75 Ω
22.0 pF/ft72.2 pF/m
PE PVC-IIABC-S
0.332 in
8.43 mm
0.0285 CW
7507-
7Coax Cable 95 Ω
12.5 pF/ft41.0 pF/m
Air space
PEPVC-I BC
0.370 in
9.40 mm
0.0359 BC
8507-
8Coax Cable 52 Ω
29.5 pF/ft96.8 pF/m
PE PVC-I BC
0.405 in
10.3 mm
7/21 BC
8A*507-8A
Coax Cable 52 Ω
29.5 pF/ft96.8 pF/m
PE PVC-IIA BC
0.405 in
10.3 mm
7/21 BC
9507-
9Coax Cable 50 Ω
30.0 pF/ft98.4 pF/m
PE PVC-IIBC-S
0.420 in
10.7 mm
7/21 S
9A507-9A
Coax Cable 50 Ω
30.0 pF/ft98.4 pF/m
PE PVC-II 2 S
0.420 in
10.7 mm
7/21 S
9B*507-9B
Coax Cable 50 Ω
30.0 pF/ft98.4 pF/m
PE PVC-IIA 2 S
0.420 in
10.7 mm
7/21 S
10507-10
Coax Cable 52 Ω
29.5 pF/ft96.8 pF/m
PEPVC-II
w/armorBC
0.475 in
12.1 mm
7/21 BC
10A*507-10A
Coax Cable 52 Ω
29.5 pF/ft96.8 pF/m
PEPVC-IIA w/armor
BC
0.475 in
12.1 mm
7/21 BC
11507-11
Coax Cable 75 Ω
22.0 pF/ft72.2 pF/m
PE PVC-I BC
0.405 in
10.3 mm
7/26 TC
11A*507-11A
Coax Cable 75 Ω
22.0 pF/ft72.2 pF/m
PE PVC-IIA BC
0.405 in
10.3 mm
7/26 TC
12507-12
Coax Cable 75 Ω
20.5 pF/ft67.3 pF/m
PEPVC-II
w/armorBC
0.475 in
12.1 mm
7/26 TC
12A*507-12A
Coax Cable 75 Ω
20.5 pF/ft67.3 pF/m
PEPVC-IIA w/armor
BC
0.475 in
12.1 mm
7/26 TC
13507-13
Coax Cable 74 Ω
20.5 pF/ft67.3 pF/m
PE PVC-I2
BC
0.420 in
10.7 mm
7/26 TC
13A*507-13A
Coax Cable 74 Ω
20.5 pF/ft67.3 pF/m
PE PVC-IIA2
BC
0.420 in
10.7 mm
7/26 TC
14507-14
Coax Cable 52 Ω
29.5 pF/ft96.8 pF/m
PE PVC-II2
BC
0.545 in
13.8 mm
0.1020 BC
14A*507-14A
Coax Cable 52 Ω
29.5 pF/ft96.8 pF/m
PE PVC-IIA2
BC
0.545 in
13.8 mm
0.1020 BC
15507-15
Coax Cable 76 Ω
20.0 pF/ft65.6 pF/m
PE PVC-I2
BC
0.545 in
13.8 mm
0.0571 CW
16507-16
Coax Cable 52 Ω
29.5 pF/ft96.8 pF/m
PE PVC-I BC
0.630 in
16.0 mm
0.125 BC tube
17507-17
Coax Cable 52 Ω
29.5 pF/ft96.8 pF/m
PE PVC-II BC
0.879 in
22.3 mm
0.188 BC
17A*507-17A
Coax Cable 52 Ω
29.5 pF/ft96.8 pF/m
PE PVC-IIA BC
0.870 in
22.1 mm
0.188 BC
17B507-17B
Coax Cable 52 Ω
29.5 pF/ft96.8 pF/m
PE PVC-IIA 2 S
0.940 in
23.9 mm
0.188 BC
18507-18
Coax Cable 52 Ω
29.5 pF/ft96.8 pF/m
PEPVC-IA w/armor
BC
0.945 in
24.0 mm
0.188 BC
18A*507-18A
Coax Cable 52 Ω
29.5 pF/ft96.8 pF/m
PEPVC-IIA w/armor
BC
0.945 in
24.0 mm
0.188 BC
19507-19
Coax Cable 52 Ω
29.5 pF/ft96.8 pF/m
PE PVC-II BC
1.120 in
28.4 mm
0.250 BC
19A*507-19A
Coax Cable 52 Ω
29.5 pF/ft96.8 pF/m
PE PVC-IIA BC
1.120 in
28.4 mm
0.250 BC
20507-20
Coax Cable 52 Ω
29.5 pF/ft96.8 pF/m
PEPVC-II
w/armorBC
1.195 in
30.4 mm
0.250 BC
20A*507-20A
Coax Cable 52 Ω
29.6 pF/ft97.1 pF/m
PEPVC-IIA w/armor
BC
1.178 in
29.92 mm
0.250 BC
21507-21
Coax Cable 53 Ω
29.0 pF/ft95.1 pF/m
PE PVC-II 2 S
0.332 in
8.43 mm
0.0508 N
21A*507-21A
Coax Cable 53 Ω
29.0 pF/ft95.1 pF/m
PE PVC-IIA 2 S
0.332 in
8.43 mm
0.0508 N
22507-22
Coax Cable 95 Ω
18.4 pF/ft60.4 pF/m
PE PVC-IIA2
TC
0.420 in
10.7 mm
2 cond. 7/0.0152
BC
22A507-22A
Coax Cable 95 Ω
16.3 pF/ft53.5 pF/m
PE PVC-IIA2
TC
0.420 in
10.7 mm
2 cond. 7/0.0152
BC
22B*507-22B
Coax Cable 95 Ω
16.3 pF/ft53.5 pF/m
PE PVC-IIA2
TC
0.420 in
10.7 mm
2 cond. 7/0.0152
BC
23507-23
Coax Cable125 Ω
13.0 pF/ft42.7 pF/m
PE PVC-I2
BC
0.650 x
0.945 in
16.5 x 24.0 mm
2 cond. 7/21 BC
23A*507-23A
Coax Cable125 Ω
13.0 pF/ft42.7 pF/m
PE PVC-IIA2
BC
0.650 x
0.945 in
16.5 x 24.0 mm
2 cond. 7/21 BC
24 507- Coax Cable 125 13.0 pF/ft
PE PVC-I 2 0.735 x
2 cond.
24 Ω42.7 pF/m
w/armor BC
1.034 in
18.7 x 26.3 mm
7/21 BC
24A*507-24A
Coax Cable125 Ω
13.0 pF/ft42.7 pF/m
PEPVC-IIA w/armor
2 BC
0.735 x
1.034 in
18.7 x 26.3 mm
2 cond. 7/21 BC
25*507-25
Coax Cable 48 Ω
50.0 pF/ft164
pF/m
RubberRubber-
IV2
TC
0.505 in
12.8 mm
19/0.0117 TC
25A*507-25A
Coax Cable 48 Ω
50.0 pF/ft164
pF/m
RubberRubber-
IV2
TC
0.505 in
12.8 mm
19/0.0117 TC
26*507-26
Coax Cable 48 Ω
50.0 pF/ft164
pF/m
RubberRubber-
IV w/armor
TC
0.525 in
13.3 mm
19/0.0117 TC
26A*507-26A
Coax Cable 48 Ω
50.0 pF/ft164
pF/m
RubberRubber-
IV w/armor
TC
0.505 in
12.8 mm
19/0.0117 TC
27507-27
Coax Cable 48 Ω
50.0 pF/ft164
pF/m
Rubber PVC-II TC
0.675 in
17.1 mm
19/0.0185 TC
RG/U
No.
Catalog No.
TypeNom. Imp.
Cap.
Dielect. Mat.
Jacket Shield
Overall
Diameter
Size (in) and Type of Inne
r Cond.
27A* 507-27ACoax Cable
48 Ω
50.0 pF/ft164
pF/m
Rubber
Rubber-IV
w/armorTC
0.670 in
17.0
mm
19/0.0185 TC
28 507-28Coax Cable
50 Ω
50.0 pF/ft164
pF/m
Rubber
Rubber-IV
TC GS
0.805 in
20.4
mm
19/0.0185 TC
28A 507-28ACoax Cable
50 Ω
50.0 pF/ft164
pF/m
Rubber
Rubber-IV
w/armorTC
0.805 in
20.4
mm
19/0.0185 TC
28B* 507-28B Coax Cable
48 Ω 50.0 pF/ft164
pF/m
Rubber
Rubber-IV
TC GS
0.750
max. in19.1
max.
19/0.0185 TC
mm
29 507-29Coax Cable
53.5 Ω
28.5 pF/ft93.5 pF/m
PE PE-III TC
0.184 in
4.67
mm
0.0320 BC
30 507-30Coax Cable
50 Ω
27.0 pF/ft88.6 pF/m
Copo. PVC-I BC
0.250 in
6.35
mm
7/26 BC
31 507-31Coax Cable
51 Ω
31.0 pF/ft102
pF/m
Copo. PVC-I BC
0.405 in
10.3
mm
7/21 BC
32 507-32 Coax Cable
51 Ω 29.0 pF/ft95.1 pF/m
Copo. PVC-I w/armor
BC 0.465 in
11.
7/21 BC
8 mm
33 507-33Coax Cable
51 Ω
30.0 pF/ft98.4 pF/m
PE LeadNon
e
0.470 in
11.9
mm
0.1019 BC
34 507-34Coax Cable
71 Ω
21.5 pF/ft70.5 pF/m
PE PVC-I BC
0.625 in
15.9
mm
7/21 BC
34A 507-34ACoax Cable
71 Ω
21.5 pF/ft70.5 pF/m
PE PVC-IIA BC
0.630 in
16.0
mm
7/0.0249 BC
34B* 507-34B Coax Cable
75 Ω 21.5 pF/ft70.5 pF/m
PE PVC-IIA BC 0.630 in
16.
7/.0249 BC
0 mm
35 507-35Coax Cable
75 Ω
22.0 pF/ft72.2 pF/m
PEPVC-II
w/armorBC
0.945 in
24.0
mm
0.1144 BC
35A 507-35ACoax Cable
75 Ω
22.0 pF/ft72.2 pF/m
PEPVC-IIA w/armor
BC
0.945 in
24.0
mm
0.1045 BC
35B* 507-35BCoax Cable
75 Ω
22.0 pF/ft72.2 pF/m
PEPVC-IIA w/armor
BC
0.945
max. in24.0
max.
mm
0.1045 BC
36 507-36Coax Cable
69 Ω
22.0 pF/ft72.2 pF/m
PE PVC-I BC
1.180 in
29.97
mm
0.1620 BC
37 507-37Coax Cable
52.5 Ω
38.0 pF/ft125
pF/m
Rubber-C
PE-III TC
0.210 in
5.33
mm
0.0320 TC
38 507-38Coax Cable
52.5 Ω
38.0 pF/ft125
pF/m
Rubber-C
PE-III 2 TC
0.312 in
7.92
mm
0.0453 TC
39 507-39Coax Cable
72.5 Ω
28.6 pF/ft93.8 pF/m
Rubber-C
PE-III 2 TC
0.312 in
7.92
mm
0.0253 TCW
40 507-40Coax Cable
72.5 Ω
28.0 pF/ft91.9 pF/m
Rubber-C
Rubber-IV
2 TC
0.420 in
10.7
mm
0.0253 TCW
41 507-41Coax Cable
67.5 Ω
27.6 pF/ft90.6 pF/m
Rubber-C
Rubber-IV
TC
0.425 in
10.8
mm
16/30 TC
42 507-42Coax Cable
78.6 Ω
20.0 pF/ft65.6 pF/m
PE PVC-II 2 S
0.342 in
8.69
mm
0.0285 N
43 507-43Coax Cable
95 Ω
17.6 pF/ft57.7 pF/m
Rubber-B
PVC-I BC
0.617 in
15.7
mm
2 cond. 7/21 BC
44 507-44
Stub support
ed coaxial
N/A N/A N/A N/A N/A N/A N/A
45 507-45
Stub support
ed coaxial
N/A N/A N/A N/A N/A N/A N/A
46 507-46
Stub support
ed coaxial
N/A N/A N/A N/A N/A N/A N/A
47 507-47
Stub support
ed coaxial
N/A N/A N/A N/A N/A N/A N/A
48 507-48Wavegu
ideN/A N/A N/A N/A N/A N/A N/A
49 507-49Wavegu
ideN/A N/A N/A N/A N/A N/A N/A
50 507-50Wavegu
ideN/A N/A N/A N/A N/A N/A N/A
51 507-51Wavegu
ideN/A N/A N/A N/A N/A N/A N/A
52 507-52Wavegu
ideN/A N/A N/A N/A N/A N/A N/A
53 507-53Wavegu
ideN/A N/A N/A N/A N/A N/A N/A
54 507-54Coax Cable
58 Ω
27.0 pF/ft88.6 pF/m
PE PVC-I BC
0.275 in
7.0 mm
7/26 BC
54A 507-54ACoax Cable
58 Ω
26.5 pF/ft86.9 pF/m
PE PE-III TC
0.250 in
6.4 mm
7/.0152 BC
55 507-55Coax Cable
53.5 Ω
28.5 pF/ft93.5 pF/m
PE PE-III 2 TC
0.200 in
5.1 mm
0.320 BC
55A 507-55ACoax Cable
50 Ω
28.5 pF/ft93.5 pF/m
PE PVC-IIA 2 S
0.200 in
5.1 mm
0.035 S
55B* 507-55BCoax Cable
53 Ω
28.5 pF/ft93.5 pF/m
PE PE-III 2 TC
0.200
max. in5.08
max.
mm
0.032 S
56 507-56 Coax Cable
48 Ω 50.0 pF/ft164
pF/m
Rubber-C
PVC-I 2 BC 0.535 in
13.6
19/.0117 BC
mm
57 507-57Coax Cable
95 Ω
17.0 pF/ft55.8 pF/m
PE PVC-I TC
0.625 in
15.9
mm
2 cond. 7/21 BC
57A* 507-57ACoax Cable
95 Ω
17.0 pF/ft55.8 pF/m
PE PVC-IIA TC
0.625 in
15.9
mm
2 cond. 7/21 BC
58 507-58Coax Cable
53.5 Ω
28.5 pF/ft93.5 pF/m
PE PVC-I TC
0.195 in
4.95
mm
0.0320 BC
58A 507-58A Coax Cable
50 Ω 32.2 pF/ft106
pF/m
PE PVC-I TC 0.195 in
4.95
19/33 TC
mm
58B 507-58BCoax Cable
53.5 Ω
28.5 pF/ft93.5 pF/m
PE PVC-IIA TC
0.195 in
4.95
mm
0.0320 BC
58C* 507-58CCoax Cable
50 Ω
32.2 pF/ft106
pF/m
PE PVC-IIA TC
0.195 in
4.95
mm
19/33 TC
59 507-59Coax Cable
73 Ω
22.0 pF/ft72.2 pF/m
PE PVC-II BC
0.242 in
6.15
mm
0.0226 CW
59A 507-59A Coax Cable
75 Ω 22.0 pF/ft72.2 pF/m
PE PVC-IIA BC 0.242 in
6.15
0.0226 CW
mm
59B* 507-59BCoax Cable
75 Ω
22.0 pF/ft72.2 pF/m
PE PVC-IIA BC
0.242 in
6.15
mm
0.0226 CW
60 507-60Coax Cable
50 Ω
39.0 pF/ft128
pF/m
Rubber
Rubber-IV
BC
0.425 in
10.8
mm
0.0508 stranded BC
61 507-61Special
500 ohm line
N/A N/A N/A N/A N/A N/A N/A
RG/U
No.
Catalog No.
Type
Nom.
Imp.
Cap.
Dielect.
Mat.
Jacket
Shield
Overall
Diameter
Size (in) and Type
of Inne
r Cond.
62507-62
Coax Cable
93 Ω
14.5
pF/ft
47.6
pF/m
Air space
PE
PVC-IIA
BC
0.242 in6.15 mm
0.0253 CW
62A*
507-62A
Coax Cable
93 Ω
14.5
pF/ft
47.6
pF/m
Air space
PE
PVC-IIA
BC
0.242 in6.15 mm
0.0253 CW
62 507- Coax 93 14.5
Air space
PVC- BC 0.242 in
7/32
B 62B Cable Ω
pF/ft
47.6
pF/m
PE IIA6.15 mm
CW
63507-63
Coax Cable
125 Ω
11.0
pF/ft
36.1
pF/m
Air space
PE
PVC-IIA
BC
0.405 in10.3 mm
0.0253 CW
63A
507-63A
Coax Cable
125 Ω
11.0
pF/ft
36.1
pF/m
Air space
PE
PVC-IIA
BC
0.405 in10.3 mm
0.0253 BC
63B*
507-63B
Coax Cable
125 Ω
11.0
pF/ft
36.
Air space
PE
PVC-IIA
BC 0.405 in10.3 mm
0.0253 CW
1 pF/m
64*507-64
Coax Cable
48 Ω
50.0
pF/ft
164 pF/m
Rubber-IV
Rubber-IV
2 TC
0.495 in12.6 mm
19/0.0117 TC
64A*
507-64A
Coax Cable
48 Ω
50.0
pF/ft
164 pF/m
Rubber-IV
Rubber-IV
2 TC
0.475 in12.1 mm
19/0.0117 TC
65507-65
Coax Cable
950 Ω
44.0
pF/ft
144 pF/m
PE PVC-I BC
0.405 in10.3 mm
0.0080 Forme
x F
65A*
507-65A
Coax Cable
950 Ω
44.0
pF/ft
144 pF/m
PEPVC-
IIABC
0.405 in10.3 mm
0.0080 Forme
x F
66507-66
Waveguide
N/A
N/A N/A N/A N/A N/A N/A
67507-67
Waveguide
N/A
N/A N/A N/A N/A N/A N/A
68507-68
Waveguide
N/A
N/A N/A N/A N/A N/A N/A
69507-69
Waveguide
N/A
N/A N/A N/A N/A N/A N/A
70507-70
Not assigne
d
N/A
N/A N/A N/A N/A N/A N/A
71507-71
Coax Cable
93 Ω
13.5
pF/ft
44.3
pF/m
Air space
PEPVC-I 2 TC
0.245 in6.22 mm
0.0253 CW
71A
507-71A
Coax Cable
93 Ω
13.5
pF/ft
44.3
pF/m
Air space
PEPE-III 2 TC
0.245 in6.22 mm
0.0253 CW
71B*
507-71B
Coax Cable
93 Ω
14.5
max.
pF/ft
47.6
max.
pF/m
Air space
PE
PE-IIIA
2 TC
0.250
max. in
6.35 max
. mm
0.0253 CW
72507-72
Coax Cable
150 Ω
7.8 pF/f
t26 pF/m
Air space
PEPVC-I BC
0.630 in16.0 mm
0.0253 CW
73507-73
Coax Cable
25 Ω
61.8
pF/ft
203 pF/m
PE None 2 BC
0.175 in4.45 mm
0.0320 BC
74507-74
Coax Cable
52 Ω
29.6
pF/ft
97.1
pF/m
PE
PVC-II
w/armor
2 BC
0.603 in15.3 mm
0.1020 BC
74A*
507-74A
Coax Cable
52 Ω
29.6
pF/ft
PE PVC-IIA
w/arm
2 BC 0.603 in15.3
0.1020 BC
97.1
pF/m
or mm
75507-75
Waveguide
N/A
N/A N/A N/A N/A N/A N/A
76507-76
Stub support
ed coaxial
N/A
N/A N/A N/A N/A N/A N/A
77A
507-77A
Coax Cable
48 Ω
50.0
pF/ft
164 pF/m
Rubber
PVC-IIA
2 TC
0.450 in11.4 mm
19/0.0117 TC
78A
507-78A
Coax Cable
48 Ω
50.0
pF/ft
164 pF/
Rubber
PVC-IIA
TC 0.420 in10.7 mm
19/0.0117 TC
m
79507-79
Coax Cable
125 Ω
11.0
pF/ft
36.1
pF/m
Air space
PE
PVC-I w/arm
orBC
0.475 in12.1 mm
0.0253 CW
79A
507-79A
Coax Cable
125 Ω
11.0
max.
pF/ft
36.1
max.
pF/m
Air space
PE
PVC-I w/arm
orBC
0.475 in12.1 mm
0.0253 CW
79B*
507-79B
Coax Cable
125 Ω
11.0
max.
pF/ft
Air space
PE
PVC-IIA
w/armor
BC 0.475 in12.1 mm
0.0253 CW
36.1
max.
pF/m
80507-80
Bead support
ed coaxial
N/A
N/A N/A N/A N/A N/A N/A
81*507-81
Coax Cable
50 Ω
37.0
pF/ft
121 pF/m
Mag. Ox.
NoneBC
Tube
0.325 in8.26 mm
0.0625 BC
82*507-82
Coax Cable
50 Ω
36.0
pF/ft
118 pF/m
Mag. Ox.
NoneBC
Tube
0.750 in19.1 mm
0.1250 BC
83507-83
Coax Cable
35 Ω
44.0
pF/ft
144 pF/m
PE PVC-I BC
0.405 in10.3 mm
0.1020 BC
84A*
507-84A
Coax Cable
75 Ω
21.5
pF/ft
70.5
pF/m
PE
PVC-IIA
w/lead
BC
1.000 in25.4
0 mm
0.1045 BC
85A*
507-85A
Coax Cable
75 Ω
21.5
pF/ft
70.5
pF/m
PE
PVC-IIA
w/lead
BC
1.565 in39.7
5 mm
0.1045 BC
86* 507-86
Coax Cable
200 Ω
7.8 pF/f
t26
PE None None
0.650 x
0.300 in
2 cond. 7/21 BC
pF/m
16.5 x
7.62 mm
87507-87
Coax Cable
50 Ω
29.5
pF/ft
96.8
pF/m
TFE FG-VBC &
S
0.425 in10.8 mm
7/20 S
87A*
507-87A
Coax Cable
50 Ω
29.5
pF/ft
96.8
pF/m
TFE FG-V 2 S
0.425 in10.8 mm
7/20 S
88* 507-88
Coax Cable
48 Ω
50.0
pF/ft
164 pF/m
Rubber
PVC-I 4 TC 0.515
max. in
13.1 max
.
19/0.0117 TC
mm
88A*
507-88A
Coax Cable
48 Ω
50.0
pF/ft
164 pF/m
Rubber
PVC-IIA
4 TC
0.515
max. in
13.1 max
. mm
19/0.0117 TC
88B
507-88B
Coax Cable
48 Ω
50.0
pF/ft
164 pF/m
Rubber
Rubber-IV
4 TC
0.565 in14.4 mm
19/0.0117 TC
89507-89
Coax Cable
125 Ω
10.0
pF/ft
32.8
pF/m
Air space
PEPVC-I BC
0.632 in16.1 mm
0.0253 CW
90507-90
Coax Cable
50 Ω
30.8
pF/ft
101 pF/m
PEPVC-
IIA2 TC 1 GS
0.425 in10.8 mm
7/24 S
91507-91
Waveguide
N/A
N/A N/A N/A N/A N/A N/A
92507-92
Coax Cable
46 Ω
N/ASS TFE
NoneBC
TubeN/A
0.375 BC
93507-93
Coax Cable
50 Ω
29.0
pF/ft
95.1
pF/m
TFE tape
FG-V BC
0.710 in18.0 mm
19/18 BC
94* 507-94
Coax Cable
50 Ω
29.0
pF/ft
95.
TFE tape
FG-V 2 BC 0.445 in11.3 mm
19/23 S
1 pF/m
94A
507-94A
Coax Cable
50 Ω
29.0
pF/ft
95.1
pF/m
TFE tape
FG-V 2 BC
0.500 in12.7 mm
19/22 S
95507-95
Waveguide
N/A
N/A N/A N/A N/A N/A N/A
96507-96
Waveguide
N/A
N/A N/A N/A N/A N/A N/A
RG/U No.
Catalog No.
TypeNom. Imp.
Cap.
Dielect. Mat.
Jacket Shield
Overall
Diameter
Size (in) and Type of Inne
r Cond.
97 507-97Wavegui
deN/A N/A N/A N/A N/A N/A N/A
98 507-98Wavegui
deN/A N/A N/A N/A N/A N/A N/A
99 507-99Wavegui
deN/A N/A N/A N/A N/A N/A N/A
100 507-100Coax Cable
35 Ω
44.0 pF/ft144
pF/m
PE PVC-I BC
0.242 in6.15 mm
19/0.0147 BC
101 507-101 Coax Cable
75 Ω
N/A Rubber - TC 0.588 in14.9
0.0641 BC
mm
102 507-102Coax Cable
140 Ω
N/A Rubber - TC
1.088 in27.6
4 mm
2 cond. 0.0808
BC
103 507-103Wavegui
deN/A N/A N/A N/A N/A N/A N/A
104 507-104Wavegui
deN/A N/A N/A N/A N/A N/A N/A
105 507-105Wavegui
deN/A N/A N/A N/A N/A N/A N/A
106 507-106Wavegui
deN/A N/A N/A N/A N/A N/A N/A
107 507-107Wavegui
deN/A N/A N/A N/A N/A N/A N/A
108 507-108Coax Cable
78 Ω
24.5 pF/ft80.4 pF/m
PEXL
polyolefinTC
0.235 in5.97 mm
2 cond. 7/28 TC
108A*507-108A
Coax Cable
78 Ω
24.5 pF/ft80.4 pF/m
PEXL
polyolefinTC
0.235 in5.97 mm
2 cond. 7/28 TC
109 507-109Wavegui
deN/A N/A N/A N/A N/A N/A N/A
110 507-110Wavegui
deN/A N/A N/A N/A N/A N/A N/A
111 507-111Coax Cable
95 Ω
18.4 pF/ft60.4 pF/m
PEPVC-II
w/armor2 TC
0.490 in12.4 mm
2 cond. 7/0.0152 BC
111A*507-111A
Coax Cable
95 Ω
18.4 pF/ft60.4 pF/m
PEPVC-IIA w/armor
2 TC
0.490 in12.4 mm
2 cond. 7/0.0152 BC
112 507-112Wavegui
deN/A N/A N/A N/A N/A N/A N/A
113 507-113Wavegui
deN/A N/A N/A N/A N/A N/A N/A
114 507-114Coax Cable
185 Ω
6.8 pF/ft22
pF/m
Air space
PEPVC-IIA BC
0.405 in10.3 mm
0.0070 CW
114A*507-114A
Coax Cable
185 Ω
6.8 pF/ft22
pF/m
Air space
PEPVC-IIA BC
0.405 in10.3 mm
0.0070 CW
115* 507-115Coax Cable
50 Ω
32.0 pF/ft105
pF/m
TFE tape
FG-V 2 S
0.415 in10.5 mm
7/21 S
115A*507-115A
Coax Cable
50 Ω
32.0 pF/ft105
pF/m
TFE tape
FG-V 2 S
0.415 in10.5 mm
7/21 S
116* 507-116Coax Cable
50 Ω
29.5 pF/ft96.8 pF/m
TFEFG-V
w/armor2 S
0.475 in12.1 mm
7/20 S
117* 507-117Coax Cable
50 Ω
29.5 pF/ft96.8 pF/m
TFE FG-V BC
0.730 in18.5 mm
0.188 BC
117A*507-117A
Coax Cable
50 Ω
29.5 pF/ft96.8 pF/m
TFE FG-V BC
0.730 in18.5 mm
0.188 BC
118* 507-118Coax Cable
50 Ω
29.0 pF/ft95.1 pF/m
TFEFG-V
w/armorBC
0.780 in19.8 mm
0.188 BC
118A*507-118A
Coax Cable
50 Ω
29.0 pF/ft95.1 pF/m
TFEFG-V
w/armorBC
0.780 in19.8 mm
0.188 BC
119* 507-119Coax Cable
50 Ω
29.3 pF/ft96.1 pF/m
TFE FG-V 2 BC
0.465 in11.8 mm
0.102 BC
120* 507-120Coax Cable
50 Ω
29.3 pF/ft96.1 pF/m
TFEFG-V
w/armor2 BC
0.523 in13.3 mm
0.102 BC
121 507-121Wavegui
deN/A N/A N/A N/A N/A N/A N/A
122* 507-122Coax Cable
50 Ω
30.8 pF/ft101
pF/m
PE PVC-IIA TC
0.160 in4.06 mm
27/36 TC
123 507-123Not
assigned
N/A N/A N/A N/A N/A N/A N/A
124 507-124Coax Cable
73 Ω
20.3 pF/ft66.6 pF/m
TFE tape
FG-V TC
0.240 in6.10 mm
0.0253 TCW
125 507-125Coax Cable
150 Ω
7.8 pF/ft26
pF/m
Air space
PEPVC-IIA BC
0.600 in15.2 mm
0.0159 CW
126* 507-126Coax Cable
50 Ω
29.0 pF/ft95.1 pF/m
TFE FG-V HR
0.280 in7.11 mm
7/24 HR
128 507-128Coax Cable
50 Ω
N/ASS TFE
NoneBC
Tube
1.625 in41.2
8 mm
0.644 BC
129 507-129Flexible Wavegui
deN/A N/A N/A N/A N/A N/A N/A
130* 507-130Coax Cable
95 Ω
17.0 pF/ft55.8 pF/m
PE PVC-I TC
0.625 in15.9 mm
2 cond. 7/21 BC
131* 507-131Coax Cable
95 Ω
17.0 pF/ft55.8 pF/m
PEPVC-I
w/armorTC
0.710 in18.0 mm
2 cond. 7/21 BC
132 507-132Wavegui
deN/A N/A N/A N/A N/A N/A N/A
133 507-133Coax Cable
95 Ω
16.2 pF/ft53.1 pF/m
PE PVC-I BC
0.405 in10.3 mm
0.0285 BC
133A*507-133A
Coax Cable
95 Ω
16.2 pF/ft53.1 pF/m
PE PVC-IIA BC
0.405 in10.3 mm
0.0253 BC
134 507-134Coax Cable
185 Ω
6.5 pF/ft21
pF/m
SS TFE
NoneBras
s
0.450 in11.4 mm
0.0126 BC
135 507-135Wavegui
deN/A N/A N/A N/A N/A N/A N/A
136 507-136Wavegui
deN/A N/A N/A N/A N/A N/A N/A
137 507-137Wavegui
deN/A N/A N/A N/A N/A N/A N/A
138 507-138Wavegui
deN/A N/A N/A N/A N/A N/A N/A
139 507-139Wavegui
deN/A N/A N/A N/A N/A N/A N/A
140* 507-140Coax Cable
75 Ω
21.0 pF/ft68.9 pF/m
TFE FG-V S
0.233 in5.92 mm
0.0250 SCCS
RG/U
No.
Catalog No.
Type
Nom.
Imp.
Cap.
Dielect.
Mat.
Jacket
Shield
Overall
Diameter
Size (in) and Type of Inne
r Cond.
141507-141
Coax Cable
50 Ω
29.4
pF/ft
96.5
pF/m
TFE FG-V S
0.190 in4.83 mm
0.0359
SCCS
141A*
507-141A
Coax Cable
50 Ω
29.4
pF/ft
96.5
pF/m
TFE FG-V S
0.190 in4.83 mm
0.0390
SCCS
142 507- Coax 50 29.3
TFE FEP- 2 S 0.195 in
0.0370
142 Cable Ω
pF/ft
96.1
pF/m
IX4.95 mm
SCCS
142A*
507-142A
Coax Cable
50 Ω
29.3
pF/ft
96.1
pF/m
TFEFEP-
IX2 S
0.195 in4.95 mm
0.0370
SCCS
142B*
507-142B
Coax Cable
50 Ω
29.3
pF/ft
96.1
pF/m
TFEFEP-
IX2 S
0.195 in4.95 mm
0.0370
SCCS
143 507-143
Coax Cable
50 Ω
29.4
pF/ft
96.
TFE FG-V 2 S 0.325 in8.26 mm
0.0570
SCCS
5 pF/m
143A*
507-143A
Coax Cable
50 Ω
29.4
pF/ft
96.5
pF/m
TFE FG-V 2 S
0.325 in8.26 mm
0.0590
SCCS
144*507-144
Coax Cable
75 Ω
22.0
pF/ft
72.2
pF/m
TFE FG-V S
0.410 in10.4 mm
7/25 SCC
S
145 507-145
Coax Cable
75 Ω
14.6
pF/ft
47.9
pF/
Air space
PE
Lead-tar
BC Tube
N/A 2 cond
. 0.0720 BC
m
146507-146
Coax Cable
190 Ω
6.0 pF/f
t20 pF/m
Air space TFE
FG-V BC
0.375 in9.53 mm
0.0070
CW
147507-147
Coax Cable
52 Ω
29.5
pF/ft
96.8
pF/m
PEPVC-I w/arm
orBC
1.938 in49.2
3 mm
0.250 BC
148507-148
Coax Cable
52 Ω
29.5
pF/ft
96.8
pF/m
PEPVC-I w/arm
orBC
0.800 in20.3 mm
7/21 BC
149*507-149
Coax Cable
75 Ω
20.5
pF/ft
67.3
pF/m
PEPVC-
IIABC
0.405 in10.3 mm
7/26 TC
150*507-150
Coax Cable
75 Ω
20.5
pF/ft
67.3
pF/m
PE
PVC-IIA
w/armor
BC
0.475 in12.1 mm
7/26 TC
151*507-151
Coax Cable
50 Ω
N/A N/A NoneBC
Tube
0.375 in9.53 mm
0.125 BC tube
152*507-152
Coax Cable
50 Ω
N/A N/A NoneBC
Tube
6.125 in156 mm
2.60 BC
tube
153*507-153
Coax Cable
50 Ω
N/A N/A NoneBC
Tube
1.625 in41.2
8 mm
0.664 BC tube
154507-154
Coax Cable
50 Ω
N/A N/A NoneBC
Tube
3.125 in79.3
8 mm
1.315 BC tube
155507-155
Coax Cable
50 Ω
N/A N/A NoneBC
Tube
0.875 in22.2 mm
0.341 BC tube
156*507-156
Coax Cable
50 Ω
32.8
pF/ft
108 pF/m
PE & conductive PE
PVC-IIA
TC, GS, TC
0.540 in13.7 mm
7/21 TC
157* 507-157
Coax Cable
50 Ω
38.0
pF/f
PE & conduct
PVC-IIA
TC, GS,
0.725 in18.4
19/24 TC
t125 pF/m
ive PE TC mm
158*507-158
Coax Cable
25 Ω
78.0
pF/ft
256 pF/m
PE & conductive PE
PVC-IIA
TC, GS, TC
0.725 in18.4 mm
37/21 TC
159507-159
Coax Cable
50 Ω
29.0
pF/ft
95.1
pF/m
TFE tape
FG-V S
0.195 in5.0 mm
0.0320 S
160 507-160
Coax Cable
125 Ω
12.0
pF/ft
39.4
pF/m
PE PVC-I BC 1.055 in26.8
0 mm
2 cond
. 19/27 TC
2 cond
.
19/27 BC
160A
507-160A
Coax Cable
125 Ω
12.0
pF/ft
39.4
pF/m
PE PVC-I BC
1.055 in26.8
0 mm
2 cond
. 19/27 TC
2 cond
. 19/27 BC
161507-161
Coax Cable
70 Ω
20.9
pF/ft
68.6
pF/m
TFE nylon S
0.082 in2.1 mm
7/38 SCB
162507-162
Coax Cable
175 Ω
N/A SS TFE NoneBC
Tube
3.065 in77.8
5 mm
0.156 BC tube
163507-163
Waveguide
N/A N/A N/A N/A N/A N/A N/A
164*507-164
Coax Cable
75 Ω
22.0
pF/ft
72.2
pF/m
PEPVC-
IIABC
0.870 in22.1 mm
0.1045 BC
165*507-165
Coax Cable
50 Ω
29.3
pF/ft
96.1
pF/m
TFE FG-V S
0.410 in10.4 mm
7/20 S
166* 507-166
Coax Cable
50 Ω
29.3
pF/ft
96.1
pF/
TFE FG-V w/arm
or
S 0.470 in11.9 mm
7/20 S
m
167507-167
Waveguide
N/A N/A N/A N/A N/A N/A N/A
168507-168
Waveguide
N/A N/A N/A N/A N/A N/A N/A
169507-169
Waveguide
N/A N/A N/A N/A N/A N/A N/A
170507-170
Waveguide
N/A N/A N/A N/A N/A N/A N/A
171507-171
Waveguide
N/A N/A N/A N/A N/A N/A N/A
172507-172
Waveguide
N/A N/A N/A N/A N/A N/A N/A
173507-173
Waveguide
N/A N/A N/A N/A N/A N/A N/A
174*507-174
Coax Cable
50 Ω
32.2
pF/ft
106 pF/m
PEPVC-
IIATC
0.110 in2.79 mm
7/34 CW
174A*
507-174A
Coax Cable
50 Ω
30.8
pF/ft
101 pF/m
PEPVC-
IIATC
0.100 in2.54 mm
7/34 CW
175507-175
Bead support
ed coaxial
line
N/A N/A N/A N/A N/A N/A N/A
176* 507-176
Coax Cable
2240 Ω
49.0
pF/ft
161 pF/
PE PVC-I BC 0.405 in10.3 mm
0.135 BC helix
m
177*507-177
Coax Cable
50 Ω
32.2
pF/ft
106 pF/m
PEPVC-
IIA2 S
0.895 in22.7 mm
0.195 BC
178507-178
Coax Cable
50 Ω
32.0
pF/ft
105 pF/m
TFEFEP-
IXS
0.079
max. in
2.01 max
. mm
7/38 SCW
178A*
507-178A
Coax Cable
50 Ω
32.0
pF/ft
105 pF/m
TFEFEP-
IXS
0.075
max. in
1.91 max
. mm
7/38 SCW
178B*
507-178B
Coax Cable
50 Ω
32.0
pF/ft
105 pF/m
TFEFEP-
IXS
0.075
max. in
1.91 max
. mm
7/38 SCW
179507-179
Coax Cable
75 Ω
23.0
pF/ft
75.5
pF/m
TFEFEP-
IXS
0.100
max. in
2.54 max
. mm
7/38 SCC
S
179A*
507-179A
Coax Cable
75 Ω
23.0
pF/ft
75.5
pF/m
TFEFEP-
IXS
0.105
max. in
2.67 max
. mm
7/38 SCC
S
179B*
507-179B
Coax Cable
75 Ω
23.0
pF/f
TFE FEP-IX
S 0.105
max
7/38 SCC
t75.5
pF/m
. in2.67 max
. mm
S
180507-180
Coax Cable
95 Ω
15.4
pF/ft
50.5
pF/m
TFEFEP-
IXS
0.141
max. in
3.58 max
. mm
7/38 SCC
S
RG/U No.
Catalog No.
TypeNom. Imp.
Cap.
Dielect. Mat.
Jacket Shield
Overall
Diameter
Size (in) and Type of Inne
r Cond.
180A* 507-180A
Coax Cable
95 Ω 15.4 pF/ft50.5 pF/m
TFE FEP-IX S 0.145
max. in3.68
max
7/38 SCCS
. mm
180B*507-180B
Coax Cable
95 Ω
15.4 pF/ft50.5 pF/m
TFE FEP-IX S
0.145
max. in3.68
max.
mm
7/38 SCCS
181*507-181
Coax Cable
125 Ω
12.0 pF/ft39.4 pF/m
PE PVC-IIA BC
0.640 in
16.3
mm
2 cond. 7/26 BC
182507-182
Coax Cable
125 each
Ω
12.0 each pF/ft39.4 each pF/m
PE PVC-IIA 2 BC
1.055 in
26.8
mm
2 cond. 19/0.0
142 BC 2 cond. 19/0.0066 TC
183507-183
Coax Cable
50 Ω
23.0 pF/ft75.5 pF/m
PS helix
NoneAL
Tube
0.750 in
19.1
mm
0.0251 BC
184507-184
Waveguide
N/A N/A N/A N/A N/A N/A N/A
185507-185
Coax Cable
2000 Ω
N/AAir
space PE
PVC-IIAMagn
et wire
0.282 in
7.16
mm
0.0031 RIM helix
186507-186
Coax Cable
1000 Ω
N/ASS PE
PVC-IIAMagn
et wire
0.405 in
10.3
mm
0.0080 TFE
Magnet wire helix
187 507-187
Coax Cable
75 Ω 19.5 pF/ft64.0 pF/m
TFE TFE S 0.110
max. in
7/38 SCCS
2.79
max.
mm
187A*507-187A
Coax Cable
75 Ω
19.5 pF/ft64.0 pF/m
TFE TFE S
0.110
max. in2.79
max.
mm
7/38 SCCS
188*507-188
Coax Cable
50 Ω
29.0 pF/ft95.1 pF/m
TFE TFE S
0.110
max. in2.79
max.
mm
7/0.0067
SCCS
188A* 507-188A
Coax Cable
50 Ω 29.0 pF/ft95.1 pF/m
TFE TFE S 0.110
max. in
7/0.0067
SCCS
2.79
max.
mm
189507-189
Coax Cable
50 Ω
23.0 pF/ft75.5 pF/m
PS helix
PE-IIIA 2 S
0.875 in
22.2
mm
0.251 BC
190*507-190
Coax Cable
50 Ω
50.0 pF/ft164
pF/m
Rubber
Neoprene® VIII
TC, GS, TC
0.700 in
17.8
mm
19/0.0117 TC
191*507-191
Coax Cable
25 Ω
85.0 pF/ft279
pF/m
Rubber
Neoprene® VIII
TC, GS, TC
1.460 in
37.1
mm
TC braid 0.485
192507-192
Coax Cable
12.5 Ω
175.0 pF/ft574.1 pF/m
Butyl rubbe
rRubber
TC, GS, GS
2.165 in
55.0
mm
TC braid GS tube
193507-193
Coax Cable
12.5 Ω
159.0 pF/ft521.7 pF/m
Silicone
rubber
RubberTC, GS, GS
2.165 in
55.0
mm
TC braid GW tube
194507-194
Coax Cable
12.5 Ω
159.0 pF/ft521.7 pF/m
Silicone
rubber
Rubber w/AL
armour
TC, GS, GS
2.01
max. in51.1
max.
mm
TC braid GW tube
195* 507-195
Coax Cable
95 Ω 15.0 pF/ft49.2 pF/m
TFE TFE S 0.155
max. in3.94
7/38 SCCS
max.
mm
195A*507-195A
Coax Cable
95 Ω
15.0 pF/ft49.2 pF/m
TFE TFE S
0.155
max. in3.94
max.
mm
7/38 SCCS
196*507-196
Coax Cable
50 Ω
28.5 pF/ft93.5 pF/m
TFE TFE S
0.080
max. in2.03
max.
mm
7/38 SCCS
196A* 507-196A
Coax Cable
50 Ω 28.5 pF/ft93.5 pF/m
TFE TFE S 0.080
max. in2.03
7/38 SCCS
max.
mm
197507-197
Coax Cable
50 Ω
22.0 pF/ft72.2 pF/m
PS helix
NoneAL
Tube
0.875 in
22.2
mm
0.300 BC
198507-198
Coax Cable
70 Ω
16.0 pF/ft52.5 pF/m
PS helix
PEAL
Tube
0.600 in
15.2
mm
0.114 BC
199507-199
Coax Cable
70 Ω
16.0 pF/ft52.5 pF/m
PS helix
PEAL
Tube
1.015 in
25.8
mm
0.209 BC
200 507-200
Coax Cable
70 Ω 16.0 pF/ft52.5
PS helix
PE AL Tube
1.765 in
0.403 BC
pF/m44.8
mm
201507-201
Rigid wavegui
deN/A N/A N/A N/A N/A N/A N/A
202507-202
Rigid wavegui
deN/A N/A N/A N/A N/A N/A N/A
203507-203
Rigid wavegui
deN/A N/A N/A N/A N/A N/A N/A
204507-204
Rigid wavegui
deN/A N/A N/A N/A N/A N/A N/A
205507-205
Rigid wavegui
deN/A N/A N/A N/A N/A N/A N/A
206507-206
Rigid wavegui
deN/A N/A N/A N/A N/A N/A N/A
207507-207
Rigid wavegui
deN/A N/A N/A N/A N/A N/A N/A
208507-208
Rigid wavegui
deN/A N/A N/A N/A N/A N/A
19/0.038 S
209*507-209
Coax Cable
50 Ω
26.5 pF/ft86.9 pF/m
Air space TFE
Silicone rubber &
FG2 S
0.750
max. in19.1
max.
mm
19/0.0378 SC
210* 507-210
Coax Cable
93 Ω 14.5 pF/ft47.6 pF/m
Air space TFE
FG-V S 0.242 in
6.15
0.0253 BC
mm
211*507-211
Coax Cable
50 Ω
29.3 pF/ft96.1 pF/m
TFE FG-V BC
0.730 in
18.5
mm
0.190 BC
211A*507-211A
Coax Cable
50 Ω
29.4 pF/ft96.5 pF/m
TFE FG-V BC
0.730 in
18.5
mm
0.190 BC
212*507-212
Coax Cable
50 Ω
30.8 pF/ft101
pF/m
PE PVC-IIA 2 S
0.332 in
8.4 mm
0.0556 SC
213* 507-213
Coax Cable
50 Ω 30.8 pF/ft101
pF/m
PE PVC-IIA BC 0.405 in
10.3
7/0.0296 BC
mm
214*507-214
Coax Cable
50 Ω
32.2 pF/ft106
pF/m
PE PVC-IIA 2 S
0.425 in
10.8
mm
7/0.0296 SC
215*507-215
Coax Cable
50 Ω
30.8 pF/ft101
pF/m
PEPVC-IIA w/
armorBC
0.475 in
12.1
mm
7/0.0296 BC
216*507-216
Coax Cable
75 Ω
22.0 pF/ft72.2 pF/m
PE PVC-IIA 2 BC
0.425 in
10.8
mm
7/26 TC
217* 507-217
Coax Cable
50 Ω 32.2 pF/ft106
pF/m
PE PVC-IIA 2 BC 0.545 in
13.8
0.106 BC
mm
218*507-218
Coax Cable
50 Ω
32.2 pF/ft106
pF/m
PE PVC-IIA BC
0.870 in
22.1
mm
0.195 BC
219*507-219
Coax Cable
50 Ω
32.2 pF/ft106
pF/m
PEPVC-IIA w/
armorBC
0.945
max. in24.0
max.
mm
0.195 BC
220*507-220
Coax Cable
50 Ω
30.8 pF/ft101
pF/m
PE PVC-IIA BC
1.120 in
28.4
mm
0.260 BC
221* 507- Coax 50 Ω 30.8 pF/ft
PE PVC-IIA w/ BC 1.195
0.260
221 Cable101
pF/marmor
in30.4
mm
BC
222*507-222
Coax Cable
50 Ω
30.8 pF/ft101
pF/m
PE PVC-IIA 2 S
0.332 in
8.4 mm
0.0556 resista
nce
223*507-223
Coax Cable
50 Ω
30.8 pF/ft101
pF/m
PE PVC-IIA 2 S
0.212 in
5.4 mm
0.035 S
RG/U
No.
Catalog No.
Type
Nom.
Imp.
Cap.
Dielect.
Mat.
Jacket
Shield
Overall
Diameter
Size (in) and Type
of Inner Cond.
224* 507-224
Coax
Cable
50 Ω
30.8 pF/f
t101 pF/
PE PVC-IIA w/ armor
2 BC 0.615
max. in
15.6
0.106 BC
mmax
. mm
225*507-225
Coax
Cable
50 Ω
29.4 pF/f
t96.5 pF/m
TFE FG-V 2 S
0.430 in10.9 mm
7/0.0312 S
226*507-226
Coax
Cable
50 Ω
29.4 pF/f
t96.5 pF/m
Taped
TFEFG-V 2 BC
0.500 in12.7 mm
19/0.0254 S
227*507-227
Coax
Cable
50 Ω
29.4 pF/f
t96.5 pF/m
TFEFG-V
w/ armor
2 S
0.490
max. in
12.4 max
. mm
7/0.0312 S
228*507-228
Coax
Cable
50 Ω
29.4 pF/f
t96.5 pF/m
TFEFG-V
w/ armor
BC
0.795
max. in
20.2 max
. mm
0.190 BC
228A*
507-228A
Coax
Cable
50 Ω
29.4 pF/f
t96.5 pF/m
TFEFG-V
w/ armor
BC
0.795
max. in
20.2 max
. mm
0.190 BC
229507-229
Coax
Cable
50 Ω
29.4 pF/f
t96.5 pF/m
TFE FG-V S
0.460 in11.7 mm
7/20 S
230* 507-230
Coax
Cable
25 Ω
100.0
pF/ft
328.
Rubber
Rubber-IV
TC, GS, GS
0.740 in18.8 mm
37/21 TC
1 pF/m
231507-231
Coax
Cable
50 Ω
25.0 pF/f
t82.0 pF/m
PE foam
NoneAl
tube
0.500 in12.7 mm
0.162 BC
tube
231A
507-231A
Coax
Cable
50 Ω
25.0 pF/f
t82.0 pF/m
PE foam
NoneAl
tube
0.500 in12.7 mm
0.162 BC
232507-232
Coax
Cable
50 Ω
22.0 pF/f
t72.2 pF/m
PE helix
PE-IIIA
Al tube
1.015 in25.7
8 mm
0.300 BC
233 507-233
Coax
Cab
50 Ω
22.0 pF/f
t
PS helix
PE-IIIA
Al tube
1.765 in44.8
BC tube
le72.2 pF/m
3 mm
234507-234
Coax
Cable
50 Ω
22.0 pF/f
t72.2 pF/m
PS helix
PE-IIIA
Al tube
3.295 in83.6
9 mm
BC tube
235*507-235
Coax
Cable
50 Ω
29.5 pF/f
t96.8 pF/m
TFE tape
Silicone
rubber
2 S
0.470
max. in
11.9 max
. mm
7/21 S
236507-236
Coax
Cable
50 Ω
24.0 pF/f
t78.7 pF/m
PS helix
NoneAl
tube
0.500 in12.7 mm
0.162 BC
237507-237
Coax
Cable
50 Ω
24.0 pF/f
t78.7 pF/m
PS helix
PE-IIIA
Al tube
0.600 in15.2 mm
0.162 BC
238507-238
Coax
Cable
N/A N/A N/A N/A N/A N/A N/A
239507-239
Coax
Cable
N/A N/A N/A N/A N/A N/A N/A
240507-240
Coax
Cable
50 Ω
22.0 pF/f
t72.2 pF/m
PS helix
NoneAl
tube
1.625 in41.2
8 mm
BC tube
241 507-241
Coax
Cab
N/A N/A N/A N/A N/A N/A N/A
le
242507-242
Coax
Cable
50 Ω
22.0 pF/f
t72.2 pF/m
PS helix
NoneAl
tube
3.125 in79.3
8 mm
BC tube
243507-243
Coax
Cable
N/A N/A N/A N/A N/A N/A N/A
244507-244
Coax
Cable
75 Ω
15.5 pF/f
t50.9 pF/m
PS helix
NoneAl
tube
0.500 in12.7
0 mm
0.102 BC
245507-245
Coax
Cable
75 Ω
15.5 pF/f
t50.9 pF/m
PS helix
PE-IIIA
Al tube
0.600 in15.2
4 mm
0.102 BC
246507-246
Coax
Cable
75 Ω
15.5 pF/f
t50.9 pF/m
PS helix
NoneAl
tube
0.875 in22.2
3 mm
0.188 BC
247507-247
Coax
Cable
75 Ω
15.5 pF/f
t50.9 pF/m
PS helix
PE-IIIA
Al tube
1.015 in25.7
8 mm
0.188 BC
248507-248
Coax
Cable
75 Ω
15.0 pF/f
t49.2 pF/m
PS helix
NoneAl
tube
1.625 in41.2
8 mm
0.370 BC
249507-249
Coax
Cable
75 Ω
15.0 pF/f
t49.2 pF/m
PS helix
PE-IIIA
Al tube
1.765 in44.8
3 mm
0.370 BC
250507-250
Coax
Cable
75 Ω
15.0 pF/f
t49.2 pF/m
PS helix
NoneAl
tube
3.125 in79.3
8 mm
0.732 BC
251507-251
Coax
Cable
75 Ω
15.0 pF/f
t49.2 pF/m
PS helix
PE-IIIA
Al tube
3.295 in83.6
9 mm
0.732 BC
252507-252
Coax
Cable
75 Ω
24.4 pF/f
t80.1 pF/m
PE tube
NoneAl
tube
0.530 in13.4
6 mm
0.167 BC
253 507-253
Coax
Cable
75 Ω
24.4 pF/f
t80.1 pF/m
PE tube
PE Al tube
0.635
max. in
16.1 max
.
0.167 BC
mm
254507-254
Coax
Cable
50 Ω
24.4 pF/f
t80.1 pF/m
PE tube
PEAl
tube
1.100
max. in
27.94
max.
mm
0.311 BC
255507-255
Coax
Cable
50 Ω
24.4 pF/f
t80.1 pF/m
PE tube
NoneAl
tube
0.953 in24.2
1 mm
0.311 BC
256507-256
Coax
Cable
50 Ω
23.5 pF/f
t77.1 pF/m
TFE tube
NoneAl
tube
0.953 in24.2
1 mm
S tube
257 507- Coax
50 24.4 pF/f
PS None Al 1.786 in
BC
257Cable
Ω
t80.1 pF/m
tube tube45.3
6 mm
tube
258507-258
Coax
Cable
50 Ω
24.4 pF/f
t80.1 pF/m
PE tube
PEAl
tube
1.936
max. in
49.17
max.
mm
BC tube
259507-259
Coax
Cable
50 Ω
23.5 pF/f
t77.1 pF/m
TFE tube
NoneAl
tube
0.390 in9.91 mm
0.115 BC
260507-260
Coax
Cable
50 Ω
23.5 pF/f
t77.1 pF/m
PE tube
PE-IIIA
Al tube
0.450 in11.4 mm
0.115 BC
261507-261
Coax
Cable
50 Ω
23.5 pF/f
t77.1 pF/m
PE tube
NoneAl
tube
3.370 in85.6
0 mm
BC tube
262507-262
Coax
Cable
50 Ω
23.5 pF/f
t77.1 pF/m
PE tube
PEAl
tube
3.520 in89.4
1 mm
BC tube
263507-263
Coax
Cable
50 Ω
21.5 pF/f
t70.5 pF/m
Air spac
e TFE
NoneAl
tube
0.500 in12.7 mm
0.172 BC
264507-264
Coax
Cable
40 Ω
38.0 pF/f
t125 pF/m
PEPVC-
IIA2 BC 2 TC
0.750 in19.1 mm
4 x 19/27
BC
264A
507-264A
Coax
Cable
40 Ω
38.0 pF/f
t125 pF/m
PE PU2 BC 2 TC
0.750 in19.1 mm
4 x 19/27
BC
264B
507-264B
Coax
Cable
40 Ω
42.0 max
. pF/f
t138 max
. pF/m
PE PU2 BC 2 TC
0.750 in19.1 mm
4 x 19/27
BC
264C
507-264C
Coax
Cable
40 Ω
42.0 max
. pF/f
t138 max
. pF/m
PE PU2 BC 2 TC
0.750 in19.1 mm
2 x 13 BC 2 x 13 TC
265507-265
Coax
Cable
50 Ω
22.3 pF/f
t73.2 pF/m
PS helix
PE-IIIA
CCS tube
2.070 in52.5
8 mm
BC tube
266*507-266
Coax
Cable
1530 Ω
53.0 pF/f
t174 pF/m
PE PVC-I BC
0.400 in10.2 mm
0.144 BC
helix
267507-267
Coax
Cable
50 Ω
22.2 pF/f
t72.8 pF/m
PS helix
PE-IIICCS tube
1.190 in30.2
3 mm
BC tube
268507-268
Coax
Cable
50 Ω
23.0 pF/f
t75.5 pF/m
PS helix
NoneBC
Tube
0.500 in12.7 mm
0.160 BC
269507-269
Coax Cable
50 Ω
22.2 pF/ft72.8 pF/m
PS helix
NoneBC
Tube
1.005 in25.5
3 mm
BC tube
270 507-270Coax Cable
50 Ω
22.3 pF/ft73.2 pF/m
PS helix NoneBC
Tube
1.830 in46.4
8 mm
BC tube
271 507-271Waveguid
eN/A N/A N/A N/A N/A N/A N/A
272 507-272Waveguid
eN/A N/A N/A N/A N/A N/A N/A
273 507-273Waveguid
eN/A N/A N/A N/A N/A N/A N/A
274 507-274Waveguid
eN/A N/A N/A N/A N/A N/A N/A
275 507-275Waveguid
eN/A N/A N/A N/A N/A N/A N/A
276 507-276Waveguid
eN/A N/A N/A N/A N/A N/A N/A
277 507-277Waveguid
eN/A N/A N/A N/A N/A N/A N/A
278 507-278Waveguid
eN/A N/A N/A N/A N/A N/A N/A
279* 507-279Coax Cable
75 Ω
17.0 pF/ft55.8 pF/m
Air space TFE
FG-V S
0.145 in3.68 mm
19/36 SCCS
280* 507-280Coax Cable
50 Ω
25.4 pF/ft83.3 pF/m
Taped TFE
FEP-IX 2 S
0.480 in12.2 mm
0.1144 BC
281 507-281Coax Cable
50 Ω
25.4 pF/ft83.3 pF/m
Taped TFE
SR & braid 2 S
0.750 in19.1 mm
19/0.0378 S
282 507-282Coax Cable
54.6 Ω
28.2 pF/ft92.5 pF/m
Irradiated PE
FEP 2 S
0.200 in5.08 mm
0.0253 S
283 507-283Coax Cable
46 Ω
50.0 pF/ft164
pF/m
Rubber Rubber-IV 2 S
0.475
max. in
12.1 max
. mm
19/0.177 S
284A507-284A
Coax Cable
75 Ω
15.0 pF/ft49.2 pF/m
PE helix NoneBC
Tube
1.005 in25.5
3 mm
0.220 BC
285A507-285A
Coax Cable
100 Ω
13.0 pF/ft42.7 pF/m
TFE helix NoneBC
Tube
1.005 in25.5
3 mm
0.1140 BC
286 507-286Coax Cable
75 Ω
15.1 pF/ft49.5 pF/m
PE helix NoneBC
Tube
1.830 in46.4
8 mm
BC tube
287 507-287Coax Cable
100 Ω
13.5 pF/ft44.3 pF/m
PE helix NoneBC
Tube
1.830 in46.4
8 mm
0.197 BC
288 507-288Coax Cable
50 Ω
21.6 pF/ft70.9 pF/m
PE helix NoneCCS tube
3.750 in95.2
5 mm
BC tube
289 507-289Coax Cable
75 Ω
14.7 pF/ft48.2 pF/m
PE helix NoneCCS tube
3.750 in95.2
5 mm
CCS tube
290 507-290Waveguid
eN/A N/A N/A N/A N/A N/A N/A
291 507-291Waveguid
eN/A N/A N/A N/A N/A N/A N/A
292 507-292Coax Cable
75 Ω
15.1 pF/ft49.5 pF/m
PE helix PE FCBC
Tube
1.830 in46.4
8 mm
BC tube
293 507-293Coax Cable
50 Ω
30.8 pF/ft101
pF/m
PE PE-IIIA S
0.545 in13.8 mm
0.106 BC
293A507-293A
Coax Cable
50 Ω
30.8 pF/ft101
pF/m
PE PE-IIIA S
0.545 in13.8 mm
0.106 BC
294 507-294Coax Cable
95 Ω
16.3 pF/ft53.5 pF/m
PE PE-IIIA TC
0.630 in16.0 mm
0.0808 BC
0.0808 TC
294A507-294A
Coax Cable
95 Ω
16.3 pF/ft53.5 pF/m
PE PE-IIIA S
0.630 in16.0 mm
0.0808 BC
0.0808 TC
295 507-295Coax Cable
50 Ω
30.8 pF/ft101
pF/m
PE PE-IIIA S
0.895 in22.7 mm
0.195 BC
296* 507-296Coax Cable
50 Ω
36.4 pF/ft119
pF/m
Silicone rubber
Neoprene® S
1.190 in30.2
3 mm
37/0.0336 S
297 507-297Coax Cable
50 Ω
21.4 pF/ft70.2 pF/m
TFE helix NoneBC
Tube
1.005 in25.5
3 mm
BC tube
298 507-298Coax Cable
N/A N/A PE PE foamNon
e
0.650 in16.5 mm
7/24 CCS
301* 507-301Coax Cable
50 Ω
32.0 pF/ft105
pF/m
TFE FEP-IX HR
0.245 in6.22 mm
7/0.0203 HR
302* 507-302Coax Cable
75 Ω
19.5 pF/ft64.0 pF/m
TFE FEP-IX S
0.206
max. in
5.23 max
. mm
0.025 SCCS
303* 507-303Coax Cable
50 Ω
29.4 pF/ft96.5 pF/m
TFE FEP-IX S
0.170 in4.32 mm
0.039 SCCS
304* 507-304Coax Cable
50 Ω
29.4 pF/ft96.5 pF/m
TFE FEP-IX 2 S
0.280 in7.11 mm
0.059 SCCS
305 507-305 Coax Cable
75 Ω 19.5 pF/ft64.0
FEP PE-IIIA BC Tube
1.990 in50.5
BC tube
pF/m5
mm
306A507-306A
Coax Cable
75 Ω
16.9 pF/ft55.4 pF/m
PE foam PE-IIIAAL
Tube
1.015 in25.7
8 mm
0.173 BC
307A*507-307A
Coax Cable
75 Ω
16.7 pF/ft54.8 pF/m
PE foam PE-IIIA 2 S
0.270
max. in
6.86 max
. mm
19/0.0058 S
316* 507-316Coax Cable
50 Ω
29.4 pF/ft96.5 pF/m
TFE FEP-IX S
0.098 in2.49 mm
7/0.0067
SCCS
317 507-317Coax Cable
95 Ω
15.4 pF/ft50.5 pF/m
FEP Neoprene® TC
0.710 in18.0 mm
2 cond. 7/0.029
BC
318 507-318Coax Cable
50 Ω
22.2 pF/ft72.8 pF/m
PE helix PE-IIIABC
Tube
1.100 in27.9
4 mm
BC tube O.D.
0.3580 I.D.
0.2870
319 507-319 Coax Cable
50 Ω 22.3 pF/ft73.2 pF/m
SS PS PE-IIIA BC Tube
1.970 in50.0
4
BC tube O.D.
0.6880
mmI.D.
0.5880
321 507-321Coax Cable
50 Ω
21.7 pF/ft71.2 pF/m
SS PE NoneBC
Tube
2.850 in72.3
9 mm
BC tube
322 507-322Coax Cable
50 Ω
21.7 pF/ft71.2 pF/m
SS PE PE FCBC
Tube
3.040 in77.2
2 mm
BC tube
323 507-323Coax Cable
50 Ω
25.6 pF/ft84.0 pF/m
PE foam PE FCBC
Tube
1.060 in26.9
2 mm
BC tube
324 507-324Coax Cable
50 Ω
25.6 pF/ft84.0 pF/m
PE foam NoneBC
Tube
0.980 in24.9 mm
BC tube
325 507-325Coax Cable
50 Ω
26.3 pF/ft86.3 pF/m
PE spline PU2 SC strip
0.465
max. in
11.8 max
. mm
19/0.0200
SCCA
326 507-326 Coax Cable
50 Ω 26.3 pF/ft86.3 pF/m
PE spline PU 2 SC strip
0.779
max. in
19/0.0400
SCCA
19.8 max
. mm
327 507-327Coax Cable
50 Ω
26.3 pF/ft86.3 pF/m
PE spline PU2 SC strip
1.18 max. in
30.0 max
. mm
19/0.0640
SCCA
328*
507-
328
Coax
Cable
25 Ω
85.0 pF/ft278.
9 pF/m
Rubbere
Neoprene®
TC, GS, TC
1.460 in37.0
8 mm
TC braid
329*
507-
329
Coax
Cable
50 Ω
50.0
pF/ft
164 pF/m
Rubber
Neoprene®
TC, GS, TC
0.700 in17.8 mm
19/0.0117 TC
330507
-330
Coax
Cable
50 Ω
25.0
pF/ft
82.0
pF/m
PE foam
None SC
0.242 in6.15 mm
SC
331507
-331
Coax
Cable
50 Ω
25.0
pF/ft
82.0
pF/m
PE foam
PE-IIIAAl
tube
0.625 in15.9 mm
0.162 BC
332507
-332
Coax
Cable
50 Ω
25.0
pF/ft
82.0
pF/m
PE foam
NoneAl
tube
0.875 in22.2 mm
0.288 BC
333507
-333
Coax
Cable
50 Ω
25.0
pF/ft
82.0
pF/m
PE foam
PE-IIIAAl
tube
1.052
max. in
26.72
max.
mm
0.288 BC
334507
-334
Coax
Cable
75 Ω
17.0
pF/ft
55.8
pF/m
PE foam
NoneAl
tube
0.500 in12.7 mm
0.098 BC
335507
-335
Coax
Cable
75 Ω
17.0
pF/ft
55.8
pF/m
PE foam
PE-IIIAAl
tube
0.625 in15.9 mm
0.098 BC
336507
-336
Coax
Cable
75 Ω
16.5
pF/ft
54.1
pF/m
PE foam
NoneAl
tube
0.875 in22.2 mm
0.173 BC
360507
-360
Coax
Cable
50 Ω
25.0
pF/ft
82.0
pF/m
PE foam
PE-IIIAAl
tube
0.825 in21.0 mm
0.243 BC
366 507-
366
Coax
Cable
50 Ω
26.6
pF/ft
87.3
pF/
PE foam
PE-IIIA BC Tub
e
0.620 in15.7 mm
0.160 BC
m
367507
-367
Coax
Cable
50 Ω
21.7
pF/ft
71.2
pF/m
PE helix
PE-IIIABC Tub
e
5.200 in132.
1 mm
BC tube
369507
-369
Coax
Cable
50 Ω
23.5
pF/ft
77.1
pF/m
PE tubes
PE-IIIAAl
tube
0.470 in11.9 mm
0.177 BC
370507
-370
Coax
Cable
50 Ω
24.0
pF/ft
78.7
pF/m
PE tubes
NoneAl
tube
0.390 in9.91 mm
0.177 BC
373507
-373
Coax
Cable
N/A
N/A PE PE foamNon
e
0.650 in16.5 mm
0.0508 BC
374507
-374
Coax
Cable
N/A
N/A PE PE foamNon
e
0.650 in16.5 mm
0.0285 BC
376507
-376
Coax
Cable
50 Ω
26.0
pF/ft
85.3
pF/m
PE foam
PE-IIIAAl
tube
1.060 in26.9 mm
0.312 BC tube
377507
-377
Coax
Cable
50 Ω
24.0
pF/ft
78.7
pF/m
TFE tubes
NoneAl
tube
0.530 in13.5 mm
0.165 S tube
378507
-378
Coax
Cable
50 Ω
22.1
pF/ft
72.5
pF/m
PE helix
PE-IIIAAl
tube
2.000 in50.8 mm
BC tube
382507
-382
Rigid
Line
N/A
N/A N/A N/A N/A N/A N/A
383507
-383
Coax
Cable
100 Ω
N/A PE PE foamNon
e
0.650 in16.5 mm
2 cond. 0.0403
384507
-384
Coax
Cable
50 Ω
30.8
pF/ft
101 pF/m
PE PE foamFlat BC
0.650 in16.5 mm
0.16 BC
385507
-385
Coax
Cable
50 Ω
25.4
pF/ft
83.3
pF/m
SS TFE
OptionalAL Tub
e
0.660 in16.8 mm
0.153 S
386507
-386
Coax
Cable
N/A
N/A PE PE foamNon
e
0.650 in16.5 mm
0.0508 CCS
388 507-
388
Coax
Cable
50 Ω
30.8
pF/ft
101 pF/
PE PE-IIIA S 0.545 in13.8 mm
0.1020 BC
m
389507
-389
Coax
Cable
50 Ω
22.8
pF/ft
74.8
pF/m
PE PE-IIIA 2S
0.875 in22.2 mm
0.250 BC AL
391*
507-
391
Coax
Cable
72 Ω
23.0
pF/ft
75.5
pF/m
C PE & PE
PVC-IIA TC
0.405 in10.3 mm
7/26 TC
392*
507-
392
Coax
Cable
72 Ω
23.0
pF/ft
75.5
pF/m
C PE & PE
PVC-IIA TC
0.475 in12.1 mm
7/26 TC
393*
507-
393
Coax
Cable
50 Ω
29.4
pF/ft
96.5
TFE FEP-IX 2 S 0.390 in9.9 mm
7/0.0312 S
pF/m
400*
507-
400
Coax
Cable
50 Ω
29.4
pF/ft
96.5
pF/m
TFE FEP-IX 2 S
0.195 in4.95 mm
19/0.0077 S
401*
507-
401
Coax
Cable
50 Ω
29.4
pF/ft
96.5
pF/m
TFE NoneBC Tub
e
0.250 in6.35 mm
0.0641 S
402*
507-
402
Coax
Cable
50 Ω
29.4
pF/ft
96.5
pF/m
TFE NoneBC Tub
e
0.141 in3.58 mm
0.0360 SCCS
403*
507-
403
Coax
Cable
50 Ω
29.4
pF/ft
96.
TFE FEP-IX 2 S 0.104 in2.64 mm
7/38 SCCS
5 pF/m
404*
507-
404
Coax
Cable
50 Ω
31.5
pF/ft
103 pF/m
TFE FEP-IX S
0.075
max. in
0.191
max.
mm
7/38 SCCS
405*
507-
405
Coax
Cable
50 Ω
29.4
pF/ft
96.5
pF/m
TFE NoneBC Tub
e
0.086 in2.18 mm
0.0201 SCCS
Coax Cable Specifications
Type Specifications Image
RG213
A low loss cable with a non-contaminating jacket
Impedance: 50 ohmsPower Handling: 1800 watts 30 MHz and less
Attenuation: 1.2 dB per 100 ft at 30 MHz and less
RG214
A low loss cable with double braid and non-contaminating jacket
Impedance: 50 ohmsPower Handling: 1800 watts 30 MHz and less
Attenuation: 1.2 dB per 100 ft at 30 MHz and less
LMR400
This coax cable provides excellent performance for high power HF needs or VHF/UHF applications. Because of its solid center conductor, it is rather stiff -- but there is a more flexible version, it's called LMR-400 Ultra-flex.
Impedance: 50 ohmsPower Handling: 2100 watts 30 MHz and less
Attenuation: 0.7 dB per 100 ft at 30 MHz and less
9913
This coax cable provides excellent performance for high power HF needs or VHF/UHF applications. Because of its solid center conductor, it is rather stiff
Impedance: 50 ohmsPower Handling: 2200 watts 30 MHz and less
Attenuation: 0.8 dB per 100 ft at 30 MHz and less
RG8X
A very flexible cable suitable for HF transmit applications where an amplifier is not used.
Impedance: 50 ohms
Attenuation: 2.0 dB per 100 ft at 30 MHz and less
RG58U
This economically priced coax cable is suitable for HF applications where high power and long runs are not required.
Impedance: 50 ohms
Attenuation: 2.5 dB per 100 ft at 30 MHz and less
While not a coax cable, it seemed appropriate to include a reference to Ladder Line on this page as well
Ladder Line
There are three common versions of this 450 ohm 'windowed' line: 18 AWG, solid copper-clad steel (30%) conductors, poly-clad; 16 AWG, 19 strand copper-clad steel conductors, poly-clad and 18 AWG, 16 strand copper-clad steel conductors, poly-clad.
Impedance: 450 ohms
Power Handling: 1500 watts at 30 MHz and less for the 18 AWG and the16 AWG variety
Attenuation: NA