    The advantaes of CO2insufationdurin surical interventions

    CO2has been used as a medical as for many decades. Carbon dioxideis not only a cost-efcient alternative but, as an endoenous as, is well

    tolerated and also quickly absorbed.

    CO2 as is non-combustible and thus ideal for use in HF surery. The

    option of also connectin the insufators to the hospital's existin central

    as supply ensures smooth functionin.

    2 3

  • 7/25/2019 Co 2 Insufflation

    4/12

    CO2insufators from KARL STORZ

    The tried and tested CO2insufators ENDOFLATORand THERMOFLATOR

    from KARL STORZ offer users optimal convenience combined with maxi-mum patient safety.

    Because the actual value and set value displays are positioned clearly side

    by side, precise monitorin of insufation is quick and easy both with the

    ENDOFLATOR and the THERMOFLATOR. The set values can be set

    precisely usin touch buttons and thus optimally adapted to the patient's

    specic conditions.

    In the event of a loss of as durin the intervention (e.., due to an instru-

    ment chane or durin smoke evacuation), the automatic pressure reula-

    tion feature prevents the pneumoperitoneum from collapsin by means of

    an electronic control.

    As a further safety measure, the safety system SECUVENT, which is

    interated in both models, uarantees constant intra-abdominal pressure

    conditions. Any overpressure is immediately detected, indicated by visual

    and acoustic warnins and reduced automatically without the user havin

    to intervene.

    Via SCB (Storz Communication Bus), the insufators from KARL STORZ

    can be interated simply and in a user-friendly manner into the intellientOR of the future, OR1. Interation means that all safety-relevant data can

    be displayed in the video imae to make operatin for the sureon a hihly

    eronomic and pleasant workin experience. In combination with an SCB-

    supported camera system, this function can also be used without an SCB

    computer.

    Toether with an IMAgE 1HUB HD control unit and an IMAgE 1 H3-Z

    camera head, the insufators can even be operated directly via the prepro-

    rammed camera head buttons. To this end, the followin functions can be

    prorammed on the buttons:

    gas on/off

    Settin as well as activation/deactivation of ow values

    Settin as well as activation/deactivation of pressure values

    Volume reset

    At KARL STORZ we set reat store by compatibility and, for this rea-

    son, customers have the option of retrottin their ENDOFLATOR or

    THERMOFLATORwith an SCB module.

  • 7/25/2019 Co 2 Insufflation

    5/12

    The smooth user interface is ideal for wipe-down disinfection and thus,

    in terms of hyiene, the insufators meet the very hihest of standards.

    Flow properties

    For optimal ow results, the complete insufation chain and not just the

    device itself must be taken into account. Many factors within the chain

    serve to considerably reduce the ow set on the device. Riht at the start

    of the insufation chain, the lters sinicantly lower the ow. The LUER

    lock represents a further bottleneck which reduces the ow to a maxi-

    mum of 18 l/min. Additional instruments and endoscopes in the trocar

    all serve to reduce the ow further.

    With the correspondin hih-ow accessories, such as the HICAP

    trocars from KARL STORZ and the lters from mtp, a maximum ow of

    30 l/min can be easily achieved over the entire insufation chain riht up

    to the patient.

    4 5

  • 7/25/2019 Co 2 Insufflation

    6/12

    CO2ENDOFLATOR

    Electronic CO2ENDOFLATOR26 4305 08-1Set consistin of:

    264305 20-1 Electronic ENDOFLATORwith interated SCB module

    400 A Mains Cord

    204001 43 Silicone Tube, sterilizable

    204000 30 Universal Wrench

    200901 70 SCB Connecting Cable

    mtp Sterile Filters, packae of 10

    The CO2 ENDOFLATOR is an insufation device for universal use in

    endoscopic examinations and operations. With its CF classication,this insufator can also be used without any difculty in cardiac surgery.

  • 7/25/2019 Co 2 Insufflation

    7/12

    THERMOFLATOR

    THERMOFLATOR264320 08-1

    Set consistin of:264320 20-1 THERMOFLATORwith interated SCB module

    400 A Mains Cord

    204000 43 Silicone Tube, sterilizable

    204000 30 Universal Wrench

    200901 70 SCB Connecting Cable

    mtp Sterile Filters, packae of 10

    204320 30 OPTITHERMGas Heating Element

    with connectin cord, autoclavable

    The hih-ow insufator from KARL STORZ can be used in the elds of

    laparoscopy, proctoloy and thoracoscopy.

    Throuh combination with the new HICAPtrocar, the maximum ow of

    30 l/min can be achieved easily even when an endoscope and instru-

    ments are used.

    The CO2 as can be preheated accordinly usin the OPTITHERM

    heater in order to prevent patient hypothermia durin loner interven-

    tions.

    6 7

  • 7/25/2019 Co 2 Insufflation

    8/12

    The optimal combinationfor CO2insufation in laparoscopy and proctology

    Hih-ow CO2insufation in laparoscopy

    CO2insufation in proctoloy

    The followin combination is recommended for...

    VERESS needle 26120 JL HICAPtrocar 30103 HA/HC/HP

    Video operation rectoscope 24941 T/TK, 24942 T/TK

    THERMOFLATOR264320 08-1

    +

    ++

  • 7/25/2019 Co 2 Insufflation

    9/12

    The optimal combinationfor CO

    2insufation in the eld of gastroenterology and vascular surgery

    The use of air as an insufation as in the eld of astrointestinal endoscopy is

    extremely common. Accordin to numerous studies, however, there is a sini-cant reduction in the amount and deree of post-intervention pain when CO

    2

    as is used instead of air durin an examination.

    KARL STORZ now offers you the opportunity to connect all KARL STORZ vid-

    eoscopes with workin channel to the CO2 insufators in order to fully exploit

    the advantaes of insufation with CO2as and, in turn, sinicantly enhance

    both patient satisfaction and comfort.

    Due to its CF Classication the ENDOFLATOR can also be used in vascular

    surery, for example in combination with a vein retractor for vessel harvestin.

    The followin combination is recommended for

    8 9

    +

    +

    Electronic ENDOFLATOR264305 08-1

    Video astroscopes 138xx/139xx

    +13991 SIA Irriation and insufation

    adapter for connection to

    the workin channel of

    exible videoscopes with

    KARL STORZ irriation

    and insufation devices

    ....CO2insufation in astroenteroloy

    CO2insufation in vessel harvestin

    Vein retractor 492015 FC

  • 7/25/2019 Co 2 Insufflation

    10/12

    THERMOFLATOR Electronic ENDOFLATOR

    Article number 264320 20-1 264305 20-1

    Set pressure 0 30 mmH 0 30 mmH

    gas ow 0 30 l/min 0 20 l/min

    gas type Med. CO2

    Med. CO2

    Connection optionCentral as supply /

    cylinder

    Central as supply /

    cylinder

    ModesVERESS, semi continuous

    ow, intermittent owintermittent ow

    DisplayDiital and barraph

    display

    Diital and barraph

    display

    FeaturesSCB, SECUVENTvalve,

    VERESS modeSCB, SECUVENTvalve

    Heater Yes

    Temperature 37C, +10% / 15%

    Dimensions in mm 305 155 233 305 155 233

    OverviewTHERMOFLATORand Electronic ENDOFLATOR

  • 7/25/2019 Co 2 Insufflation

    11/12

    THERMOFLATOR

    264320 20-1

    Electronic ENDOFLATOR

    264305 20-1

    Laparoscopy

    Thoracoscopy

    Proctoscopy (TEO)

    Endoscopy of the

    upper and lower astroin-

    testinal tract

    Endoscopic vein

    harvestin

    Open, endoscopically

    assisted cardiac surery

    OverviewAreas of application

    10 11

  • 7/25/2019 Co 2 Insufflation

    12/12

    EndoWorldwww.karlstorz.com

    EWU

    NITS4-1-E/01-2011

    KARL STORZ gmbH & Co. KgMittelstrae 8, 78532 Tuttlinen, germanyPostfach 230, 78503 Tuttlinen, germanyPhone: +49 (0)7461 708-0Fax: +49 (0)7461 708-105

    E-Mail: [email protected]

    KARL STORZ Endoscopy-America, Inc.2151 East grand AvenueEl Seundo, CA 90245-5017, USAPhone: +1424218-8100,+1800421-0837Fax: +1 424 218-8526

    E-Mail: [email protected]