7
7/23/2019 CM510-62X Low-cost Low-power DTU User Guide http://slidepdf.com/reader/full/cm510-62x-low-cost-low-power-dtu-user-guide 1/7 Xiamen Caimore Communication Technology Co.,Ltd 2 F, 37#, Wanghai Road, Software Park 2, Xiamen,China (361009) Contact person: Cynthia Wang E-mail: [email protected] Skype: caimoremodem Mobile phone: +86-13720875034 Tel:+86 592 5901215 Web: www.caimore.com/emain.asp 1 CM51062X Lowcost lowpower DTU User Guide Tool First, please open the file of “CM51062X material” Then you will find 3 files as below: Want a latest firmware of CM51062X? Just use it! There are the latest firmware software & tools for downloading. CM51062X parameters confi tool,easy to confi IP, port, baud rate etc. What’s problem or faulty? Try to use this tool to find it out. What are these?

CM510-62X Low-cost Low-power DTU User Guide

  • Upload
    cynthia

  • View
    214

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CM510-62X Low-cost Low-power DTU User Guide

7/23/2019 CM510-62X Low-cost Low-power DTU User Guide

http://slidepdf.com/reader/full/cm510-62x-low-cost-low-power-dtu-user-guide 1/7

Xiamen Caimore Communication Technology Co.,Ltd2 F, 37#, Wanghai Road, Software Park 2, Xiamen,China (361009)

Contact person: Cynthia Wang E-mail: [email protected]: caimoremodem Mobile phone: +86-13720875034

Tel:+86 592 5901215 Web: www.caimore.com/emain.asp1

CM510‐62X Low‐cost low‐power DTU User Guide

Tool

First, please open the file of “CM510‐62X material”

Then you will find 3 files as below:

Want a latest firmware of CM510‐62X? Just use it! There are the latest

firmware software & tools for downloading.

CM510‐62X parameters confi tool,easy to confi IP, port, baud rate etc.

What’s problem or faulty? Try to use this tool to find it out.

What are these?

Page 2: CM510-62X Low-cost Low-power DTU User Guide

7/23/2019 CM510-62X Low-cost Low-power DTU User Guide

http://slidepdf.com/reader/full/cm510-62x-low-cost-low-power-dtu-user-guide 2/7

Xiamen Caimore Communication Technology Co.,Ltd2 F, 37#, Wanghai Road, Software Park 2, Xiamen,China (361009)

Contact person: Cynthia Wang E-mail: [email protected]: caimoremodem Mobile phone: +86-13720875034

Tel:+86 592 5901215 Web: www.caimore.com/emain.asp2

Material List

Serial Line 2pcsCM510‐62X DTU 1pc

14‐pins terminal 1pcGPRS antenna 1pc

Power Adapter 1pc   SIM Card

Page 3: CM510-62X Low-cost Low-power DTU User Guide

7/23/2019 CM510-62X Low-cost Low-power DTU User Guide

http://slidepdf.com/reader/full/cm510-62x-low-cost-low-power-dtu-user-guide 3/7

Xiamen Caimore Communication Technology Co.,Ltd2 F, 37#, Wanghai Road, Software Park 2, Xiamen,China (361009)

Contact person: Cynthia Wang E-mail: [email protected]: caimoremodem Mobile phone: +86-13720875034

Tel:+86 592 5901215 Web: www.caimore.com/emain.asp3

Wiring

●Insert SIM Card

●Connect antenna

Using a needle to push this

hole, the slot will pop up!

Put the SIM card on the slot like

this, and then intert into DTU

again.

Remove this red hood

Then connect the

antenna like this

●TIPS:

Please ensure to power off DTU

before pluge the SIM card!!

Page 4: CM510-62X Low-cost Low-power DTU User Guide

7/23/2019 CM510-62X Low-cost Low-power DTU User Guide

http://slidepdf.com/reader/full/cm510-62x-low-cost-low-power-dtu-user-guide 4/7

Xiamen Caimore Communication Technology Co.,Ltd2 F, 37#, Wanghai Road, Software Park 2, Xiamen,China (361009)

Contact person: Cynthia Wang E-mail: [email protected]: caimoremodem Mobile phone: +86-13720875034

Tel:+86 592 5901215 Web: www.caimore.com/emain.asp4

Simple and easy connection:

●Wiring illustrates

Slotted screwdriver

screwdriver

Terminal Interface front view

Insert the exposed wire into the

unscrewed terminal, and then

tighten!!!

Unscrewed it!

1 2 3 4 5 6 7 8 9   10 11 12 13 14

14‐pins terminal plan view   Serial exposed wire

Bule

Black

Brown

Power bare wires

 

Zebra

pattern

Red zone is the port for wiring!

How to

connect? Follow

me~

Page 5: CM510-62X Low-cost Low-power DTU User Guide

7/23/2019 CM510-62X Low-cost Low-power DTU User Guide

http://slidepdf.com/reader/full/cm510-62x-low-cost-low-power-dtu-user-guide 5/7

Xiamen Caimore Communication Technology Co.,Ltd2 F, 37#, Wanghai Road, Software Park 2, Xiamen,China (361009)

Contact person: Cynthia Wang E-mail: [email protected]: caimoremodem Mobile phone: +86-13720875034

Tel:+86 592 5901215 Web: www.caimore.com/emain.asp5

●Finish to wiring, then plug the terminal port into DTU

●Now it has been done!

+   ‐   BU BN   BK   BU   BN

Connect to relative

Serial exposed

wire!

Please follow this

schematic drawing to

connect the power/ serial

port’s bare wire!

Connect

power barewire

PowerCommunication

serial ort

Debug serial port

Page 6: CM510-62X Low-cost Low-power DTU User Guide

7/23/2019 CM510-62X Low-cost Low-power DTU User Guide

http://slidepdf.com/reader/full/cm510-62x-low-cost-low-power-dtu-user-guide 6/7

Xiamen Caimore Communication Technology Co.,Ltd2 F, 37#, Wanghai Road, Software Park 2, Xiamen,China (361009)

Contact person: Cynthia Wang E-mail: [email protected]: caimoremodem Mobile phone: +86-13720875034

Tel:+86 592 5901215 Web: www.caimore.com/emain.asp6

Serial port illustrates

1、Communication serial port

2、Debug serial port. It is a port to diagnose problems, which can check the debug

info when DTU communicate with the terminal device, in order to save time and

effort.

What are these serial

port used to do?

Download software

Communicatoin

Confi parameters

Page 7: CM510-62X Low-cost Low-power DTU User Guide

7/23/2019 CM510-62X Low-cost Low-power DTU User Guide

http://slidepdf.com/reader/full/cm510-62x-low-cost-low-power-dtu-user-guide 7/7

Xiamen Caimore Communication Technology Co.,Ltd2 F, 37#, Wanghai Road, Software Park 2, Xiamen,China (361009)

Contact person: Cynthia Wang E-mail: [email protected]: caimoremodem Mobile phone: +86-13720875034

Tel:+86 592 5901215 Web: www.caimore.com/emain.asp7

Power adapter

Distinguish positive &

negative, pay attention on

zebra pattern!

Communication

serial port connect

to terminal deivceDebug serial port

connect to PC

Wiring for

debugging

Terminal device,

e.g: PLC

PC